For any suggestion please contact us at [email protected] Telegärtner enters the Health sector at the PSE on Reunion Island through Promega (Réunion Island) Name of the Project: Pôle Sanitaire de l’Est (PSE) – Ile de la Réunion View of the scale model– overall plan Subject : Installation of a shielded cabling system Cat.6 class E on the new Est Health Pole (PSE). CONTRAINTES PSE TECHNICAL REQUIREMENTS ENVIRONMENT: New very extended hospital site which displays lots of long links. PERFORMANCES: Although the initial required performance of the project is Cat 6 Class E. The selected products are Cat.6 A with a NEXT margin of 6 dB. After several preparatory meetings, our client, who was already sensitive to the importance of the physical layer which is the essential for every IP infrastructure opted for an evolution technology with a minimum of 10 years vision minimum. TELEGÄRTNER is also committed in the hospital environment in mainland France (Croix Saint-Simon Hospital, Paris – 13 000m²) but also in overseas departments and territories, in Réunion Island. We entirely equip the new » Pôle Sanitaire de l’Est » (PSE) achieved in Cat 6 A class E A , as well as Félix Guyon Hospital in partnership with INEO. We also achieved Gabriel Martin Hospital in partnership with VINCI Group. for more information Key criteria: The permanent link 6 dB security margin of the link in class E A for the years to come

Upload: jean-pierre-traboulsi

Post on 16-Jul-2015

76 views

Category:

Technology


2 download

TRANSCRIPT

For any suggestion please contact us at [email protected]

Telegärtner enters the Health sector at the PSE on Reunion Island through Promega (Réunion Island)

Name of the Project: Pôle Sanitaire de l’Est (PSE) – Ile de la Réunion

View of the scale model– overall plan

Subject : Installation of a shielded cabling system Cat.6 class E on the new Est Health Pole (PSE). CONTRAINTES PSE TECHNICAL REQUIREMENTS

• ENVIRONMENT: New very extended hospital site which displays lots of long links.

• PERFORMANCES: Although the initial required performance of the project is Cat 6 Class E. The

selected products are Cat.6A with a NEXT margin of 6 dB.

After several preparatory meetings, our client, who was already sensitive to the importance of the physical layer which is the essential for every IP infrastructure opted for an evolution technology with a

minimum of 10 years vision minimum.

TELEGÄRTNER is also committed in the hospital environment in mainland France (Croix Saint-Simon Hospital, Paris – 13 000m²) but also in overseas departments and territories, in Réunion Island. We entirely equip the new » Pôle Sanitaire de l’Est » (PSE) achieved in Cat 6A class EA, as well as Félix Guyon Hospital in partnership with INEO. We also achieved Gabriel Martin Hospital in partnership with VINCI Group. for more information Key criteria: The permanent link 6 dB security margin of the

link in class EA for the years to come

For any suggestion please contact us at [email protected]

The choice of Telegärtner solutions has been possible thanks to the guaranties they could bring, in terms

of quality as well as in terms of exceptional performances of the installed links. (Category 6A, Class EA

with a minimum NEXT margin of 6 dB). Indeed, it is imperative to offer a NEXT margin security of 6 dB

and a Return loss margin of 3 dB whatever the length of the link.

Another decisive key criteria was the commitment of our local distributor PROMEGA REUNION who

brought a pre-sale technical assistance also during deployment. Besides, the installer who accomplished

the work, that is the company INEO Gdf Suez, displayed all the specific training certificates of their

technicians as well as their Fluke Networks accreditation. These parameters have been decisive to

assure to the end user the expected security in terms of installation quality, durability and performance

of Telegärtner’s solutions.

TELEGÄRTNER SOLUTION AND KEY CRITERIA OF PRODUCTS

� Mounting mating with devices in a « covered courtyard » environment

� Easy mounting and assembly

� Long lasting

� Mounting rail fixation

� MFP8 field plug

STAKE HOLDERS :

ACCREDITTED DISTRIBUTOR ACCREDITTED INSTALLER

For any suggestion please contact us at [email protected]

CONNECTION COMPONENTS :

• Connector: Shielded AMJ Cat6A J00029A0077 : The simplicity

to assemble the AMJ modules was one of the key criterion.

This outlet doesn’t need more than 60 seconds for a perfect

and durable implementation while ensuring a high level of

performance to reach an average 6dB NEXT margin in Cat.6A

class EA

• MFP8 Plugs J00026A2001 are perfect for the connection of

collective such as IP cameras, WIFI terminal blocks, graphical

displays, terminal blocks for the updating of the “ Cartes

Vitales » but also for the connection of consolidation points

and distributors.Each outlet which equips the distributors/

consolidation points is connected to a AWG solid cable. In order to connect them to the network, it is necessary to

have a plug for that. Indeed, The MFP8 field plug is designed

to be mounted on solid and stranded cable with conductor

size from AWG22/1 to AWG27/7 and when mating with the AMJ,

It forms a male/female couple most adapted to networks requirements.

• Use of patch panels H02025A0220, allowing the

connection of 24 AMJ. It is equipped with a removable designation label protected by an adhesive marking

strip B05002A0012, thus offering a clear designation of

the ports on the front plate.

• This project needed the use of category 6A U/FTP AMJ500 LSZH cable L02002A0089 (simplex),

L02002A0088 (Duplex)

For any suggestion please contact us at [email protected]

NOTE : The selected company for the achievement TELEGÄRTNER solutions is INEO Gdf Suez la Réunion.

SOLUTIONS BROUGHT BY INEO Gdf Suez la Réunion 1°) « covered courtyard » environnement

Some places are designed in « covered courtyard », that is to say below the buildings so that they can

welcome the additional beds when events of exceptional significance take place.

They are constantly in the open air exposed to the elements.

It is essential that these outlets are

permanently kept operational. The

experience of TELEGÄRTNER in inhospitable environment allowed to reply efficiently to

this very specific need.

For any suggestion please contact us at [email protected]

2°) Did you say « PERFORMANCES » ?

The PSE site is very demanding as far as its specificity is concerned. It is indeed composed of several

remote and very large property developments. Therefore it presents copper links very often of

important lengths which sometimes exceed the fateful standard length of 90m. Nevertheless we had to

meet the requirements regarding the very elitist performance level with a 4dB NEXT margin and a

Return Loss margin of 3dB.

You’ll find below a presentation of a few graphs from the measures taken on site from a FLUKE DTX

1800 tester and they show that the signal among others doesn’t collapse at 500MHz.

As for the test results made on average and long lengths, the results speak for themselves.

For any suggestion please contact us at [email protected]

INEO Gdf Suez was serious ingenuous and professional about that which allowed to optimize the

performances of Telegärtner products.

For any suggestion please contact us at [email protected]

3°) In wiring closets

Use of patch panels H02025A0220, allowing the

connection of 24 AMJ. It is equipped with a removable

designation label protected by an adhesive marking

strip B05002A0012, thus offering a clear designation of

the ports on the front plate.

Its « L » structure ensures the support of the rear

cabling. The use of U/FTP cat6A AWG23 cable imposes

both resistance to the weight of the cables and to the pressure exercised by the cable itself in its management

, which requires the use of untightened clamps Nylons,

in order not to damage the cable.

The paying of attention to the cable management in the

19’’ supports (Cabinet, Chassis, boxes…) is as important

as the implementation of the products quality.

For any suggestion please contact us at [email protected]

This project has been managed in exclusive partnership with

PROMEGA REUNION (Contact : Frédéric BARONI - Tel. : +262(0)262 92 10 04)

Contact & Support TELEGÄRTNER France :

Division DataVoice Division Coax Tél.: +33 (0)1 64 93 64 37 Tél.: +33 (0)4 94 35 73 11

Fax: +33 (0)1 64 93 64 57 Fax: +33 (0)4 94 33 79 34