lg multi v iv - indoor units

Upload: muhidin-kozica

Post on 03-Jun-2018

229 views

Category:

Documents


1 download

TRANSCRIPT

  • 8/12/2019 LG Multi V IV - Indoor Units

    1/17

    9190

    I ND

    O OR

    U NI T S

    INDOOR UNITS 092 ARTCOOL093 Wall Mounted

    095 Console

    096 Ceiling Cassette

    098 Ceiling Concealed Duct

    100 Ceiling & Floor Ceiling Suspended

    101 Floor Standing

    If you need a highly efcient air conditioning system in your building,MULTI V is the right choice for you

  • 8/12/2019 LG Multi V IV - Indoor Units

    2/17

    9392

    I ND

    O OR

    U NI T S

    You no longer need to be told what your air conditioner should look like. With LGs revolutionary ARTCOOL Gallery, you canchange the look of your air conditioner to whatever you want, whenever you want. The ARTCOOL series have outstandingdesigns and have been awarded the International Forum Design Award, the Reddot Design Award and the G Mark.

    ConventionalThe main causes of odour within airconditioners is mould andbacteria in the heat exchanger,which breeds when theheat exchanger is wet.

    The air ow can be controlled to ensure maximum comfort and convenience.

    Aesthetic Design

    Digital Air Flow Control

    Auto CleaningA major cause of air conditioner odours is mould and bacteria that can breed in the heat exchanger. The auto clean functiondries the wet heat exchanger to prevent mould and bacteria from breeding which can signicantly reduce smells and savesthe user from frequent cleaning.

    Wider Piping Space

    Installation Support Clip

    The tubing space is up to 45% wider than previousmodels for easier installation. The tubing space is widerthan many products currently on the market.

    A support clip creates adequate space between the walland the unit for easier installation.

    ARTCOOL Mirror

    Silver07/09/12/15GSEV2 18/24GS8V2

    Mirror07/09/12/15GSER2 18/24GS8R2

    Normal

    Fast, wide and even

    Jet cool

    Speedy and powerful

    Sleep mode

    Indirect and discreet

    165mm

    25

    145%

    LG

    100%

    Conventional

    Auto CleaningThe automatic cleaning function driesthe wet heat exchanger to preventthe bacteria from breeding mould.It eliminates the odour from airconditioners and can reduce the hassle

    of having to frequently clean the lter.

    WALL MOUNTEDARTCOOLGallery / Panel / Mirror

    Panel Type

    Silver07/09/12GSFV2

    Gold 07/09/12GSFG2

    Red07/09/12GSFE2

    White silver07/09/12GSFH2

    How to Change the Picture

    Ion sterilisation function removes germsand mould

    *

    *

    *

    Interior of air conditioner dried outautomatically after use

    *

    *

  • 8/12/2019 LG Multi V IV - Indoor Units

    3/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    4/179796

    I ND

    O OR

    U NI T

    S

    LGConventional

    STOP M a x . 4

    . 5 m

    Memory

    It is possible to control each of the 4 vanes individually as the motors are connected separately to each vane.

    High ceiling mode provides powerful cooling and heatingup to 4.2m in height, from ceiling to oor.

    The indoor unit with slim and compact dimensionshas reduced the restriction which enables successfulinstallation in various spaces.

    Independent Vane Control

    Auto Elevation Grille

    High Ceiling Mode

    Compact Size

    Flexible Connection

    Swirl Swing

    Convenient Panel Installation

    Flexible connection of remote controller - Group control : 1 remote controller up to 16 indoor units.- Second remote control : 2 remote controllers to 1 indoor unit

    Swirl swing distributes air evenly throughout the room to ensure a morecomfortable environment by adjusting the movement of the vane.

    The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drainconnection pipe.

    Independent Vane ControlAll vane operation Individual vane angle control

    Indirect air owDirect air ow

    Easy lter cleaning with elevation grill

    - Installation inside main body - Auto horizontal control- 4 points support structure - Memory for users level- Max 4.5m length - Model : PTEGM0

    4-Point supportstructuret

    Auto Leveling Auto Stop DetectionMemory for userslevel

    * Except ARNU05GTRC2, ARNU07GTRC2, ARNU09GTRC2, ARNU12GTRC2, ARNU15GTQC2, ARNU18GTQC2* Operating with wired remote controller PQRCVSL0(QW) and wireless remote controller included in PTEGM0.

    w a l l

    w a l l

    Easy & solid attachment to the wall

    Swirl swing (plaesant air)Normal air owComparison of temperatures

    Vert ic al t empe ra tu re d if fe rences Hor izon ta l temperatur e di ff er ences

    CEILING CASSETTE

    4.2m

    6.0~7.2 kW 8.3~11.0 kW

    conventional 218mm 288mm

    LG 204mm 246mm

    Drain leakage check Hanger adjust Detachable Corner Design

    Refrigerantpiping checkand Hangeradjust

    Drain leakagecheck andhanger adjust

    Hangeradjust

    Hanger adjust

    LGConventional

  • 8/12/2019 LG Multi V IV - Indoor Units

    5/179998

    I ND

    O OR

    U NI T

    S

    Using a spiral duct (embedded or exible type) andstream chamber, it is possible to operate cooling/heatingfor several rooms simultaneously.

    The BLDC motor and low noise fan means that air volumecan be easily controlled by using the wired remote controller.The BLDC motor can control the fan speed and air volumeregardless of the external static pressure With ESP controlno additional accessories are needed to adjust the air ow

    and the energy consumption of the fan is also reduced.

    The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit.There may be a signicant difference between ceiling and oor air temperature. Two thermistors can optimise indoor airtemperature for a more comfortable environment.

    Operation for Multiple Rooms

    External Static Pressure (ESP) Control

    Two Thermistors Control

    Variable ESP with Low Noise (Low Static Duct Only)

    Easy Service and Maintenance (Low Static Duct Only)

    Flexible Installation (Low Static Duct Only)

    The ESP of the new low static ducts can be easilycontrolled by the wired remote controller(0~50Pa).It allows the external static pressure to be nely tunedaccording to the application. In addition, the noiselevels have been reduced, in spite of the increase in themaximum ESP.

    The drain pump is installed on the surface of the product,which is detachable. Users can detach the drain pump formore convenient servicing and natural drainage.

    The new low static duct allows you to choose the air intake direction.(Back or underneath) Conventional low static ductModels only take return air from the back, this means which needs more space is needed for ducting. It is suitable forapplications which dont have enough space.

    Remote Controller

    Thermistor

    Compares temperaturessensed from differentpositions, and automaticallyselects the optimumtemperature for users

    A i r V o

    l u m e

    HML

    H ML

    External Static Pressure (mmAq)

    Conventional

    Only back Side Bottom Back

    New Low Static Duct

    Available for natural drainage

    Detachable drain pump

    CEILING CONCEALED DUCT

  • 8/12/2019 LG Multi V IV - Indoor Units

    6/17101100

    I ND

    O OR

    U NI T

    S

    The ceiling and oor models can be installed either on the ceiling or on the oor.This saves space when installed in shops or ofces.

    The lter change alarm informs you when the unit has been operating for 2,400 hours. It is very easy to clean or change the lter.

    Flexible Installation

    One Touch Filter

    Block Cold DraftThe oor standing unit can block cold drafts from windows to provide a warmer environment for places such as libraries and ofces.

    Sliding Type FilterEasy maintenance and extended product life with sliding type lter

    * Ceiling & Floor : ARNU09GVEA2, ARNU12GVEA2

    Airow Direction ControlHorizontal Airow Direction ControlAdjust the horizontal airow direction by manually moving thehorizontal airow direction loure by hand.

    Vertical Airow Direction ControlThe airow direction can be adjusted as desired by using the remotecontrol.

    One touch lter Filter Change Alarm

    Without Floor Standing With Floor Standing

    Cold Draft Block cold drafts to provide awarmer environment

    3 way Flexible InstallationIt is possible to install and connect the outdoor unit in 3different ways (side, back, oor).

    Easy cleaning

    Sliding type

    FLOOR STANDINGCEILING & FLOORCEILING SUSPENDED

    Side

    Back

    Floor

  • 8/12/2019 LG Multi V IV - Indoor Units

    7/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    8/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    9/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    10/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    11/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    12/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    13/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    14/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    15/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    16/17

  • 8/12/2019 LG Multi V IV - Indoor Units

    17/17

    123122

    I ND

    O OR

    U NI T

    S

    Art Cool Mirror Standard Console4way

    Cassette2 way

    Cassette1 way

    CassetteLow Static Built-in High Static Ceiling & Floor

    CeilingSuspended

    Floor Standing

    NEO PlasmaAir Purifying System

    Jet Cool

    Dehumidication

    Hot Start(Heat pump only)

    Child Lock Function(Wired remote controller only)

    Soft Dry Operation Mode

    Low Standby Power

    Group Control(Wired remote controller only)

    Auto Changeover(MULTI V Heat Recovery only)

    Auto Clean

    Sleep ModeAuto Operation

    Auto Restart

    4-Way Air Deection

    Swirl Swing

    Weekly Program(Wired remote controller only)

    Two Thermistor Control(Wired remote controller only)

    Changable Panel

    Second Remote Control

    FUNCTIONS