limit switches - octopartdatasheet.octopart.com/xcks131h29-telemecanique... · 3/4 te 3 limit...

18
3/2 Te 3 Limit switches Double insulated, types XCK-P and XCK-T General characteristics Environment Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14 to standards Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130 Approvals CSA A300, UL A300 Listed, NEMKO FI 10 (4) A-400 V Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C Electric shock protection Class II conforming to IEC 536 and NF C 20-030 Degree of protection IP 65 conforming to IEC 529 ; IP 653 conforming to NF C 20-010 Repeat accuracy 0.1 mm on the tripping points Cable entry XCK-P : 1 entry, tapped M16 x 1.5. XCK-T : 2 entries, tapped M16 x 1.5 For other threaded entries, please consult your Regional customer centre. Contact block characteristics Rated operational characteristics c AC-15 ; A300 (Ue = 240 V, Ie = 3 A) a DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1 Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-1 and VDE 0110, group C conforming to NF C 20-040 Ui = 300 V conforming to UL 508, CSA C22-2 n° 14 Rated withstand impulse voltage U imp = 6 kV conforming to IEC 947-1, IEC 664 Short-circuit protection 10 A cartridge fuse type gG (gl) Minimum actuation speed XES-Pi 151 : 0.001 m/minute, XEN-P21i 1 : 0.001 m/second Electrical durability Conforming to IEC 947-5-1 Appendix C. Utilisation categories AC-15 and DC-13. Maximum operating rate : 3600 operating cycles per hour. Load factor : 0.5

Upload: ngoduong

Post on 19-Mar-2018

226 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/2 Te

3

Limit switchesDouble insulated, types XCK-P and XCK-T

General characteristics

Environment

Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14to standards

Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130

Approvals CSA A300, UL A300 Listed, NEMKO FI 10 (4) A-400 V

Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C

Electric shock protection Class II conforming to IEC 536 and NF C 20-030

Degree of protection IP 65 conforming to IEC 529 ; IP 653 conforming to NF C 20-010

Repeat accuracy 0.1 mm on the tripping points

Cable entry XCK-P : 1 entry, tapped M16 x 1.5. XCK-T : 2 entries, tapped M16 x 1.5For other threaded entries, please consult your Regional customer centre.

Contact block characteristics

Rated operational characteristics ccccc AC-15 ; A300 (Ue = 240 V, Ie = 3 A)aaaaa DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1

Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-1 and VDE 0110, group C conforming toNF C 20-040

Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

Rated withstand impulse voltage U imp = 6 kV conforming to IEC 947-1, IEC 664

Short-circuit protection 10 A cartridge fuse type gG (gl)

Minimum actuation speed XES-P iiiii151 : 0.001 m/minute, XEN-P21iiiii1 : 0.001 m/second

Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5

Page 2: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/3Te

3

1314 22

21

1314 22

21

Limit switchesDouble insulated, conforming to CENELEC EN 50047, type XCK-PComplete switches with 1 cable entry, tapped M16 x 1.5

References, characteristics, function diagrams, dimensions

Type of operating head Plunger

Metal plunger Steel plunger with Thermoplastic Thermoplasticelastomer boot roller plunger roller lever plunger

References ( N/C contact with positive opening operation)

2-pole 1 N/C + 1 N/O XCK-P110H29 XCK-P111H29 XCK-P102H29 XCK-P121H29snap action(XES-P2151)

2-pole 1 N/C + 1 N/O XCK-P510H29 XCK-P511H29 XCK-P502H29 XCK-P521H29break before makeslow break (XEN-P2151)

Weight (kg) 0.055 0.055 0.055 0.060

Complementary characteristics

Switch actuation On end By 30° cam

Maximum actuation speed 0.5 m/s 0.3 m/s 1 m/s

Mechanical durability 15 million 10 million 15 millionoperating cycles operating cycles operating cycles

Minimum force for tripping 15 N 12 N 6 N

for positive opening 45 N 36 N 18 N

Cable entry 1 entry tapped M16 x 1.5 for ISO cable gland. Clamping capacity : 4 to 8 mm.Function diagramsXCK-P110H29 XCK-P111H29 XCK-P102H29 XCK-P121H29

XCK-P510H29 XCK-P511H29 XCK-P502H29 XCK-P521H29

Contact operation (A) = cam displacementg contact closed (P) = positive opening pointh contact open

DimensionsXCK-Piiiii10H29 XCK-Piiiii11H29 XCK-Piiiii02H29 XCK-Piiiii21H29

(1) 1 cable entry, tapped M16 x 1.5 for ISO cable gland Ø : 2 elongated holes Ø 4.3 x 8.3 on 22 centres, 2 holes Ø 4.3 on 20 centres

30

(1)

93,5

25

5,5

12,5

Ø

30

20/22= =

39

Ø14

204

30

(1)

74,525

12,5

30

(1)

74,525

12,5

30

20/22= =

20

Ø8

Ø4 Ø

30

20/22= =

20

Ø8

4

30

(1)

8525

3,5

12,5

Ø

30

20/22= =

30,5

Ø11

4

6,5(A)

0 mm10,5

11,3(P)21-2213-14

3,1(A)

0 mm5,2

5,6(P)21-2213-14

1,8

0 5mm3

3,2(P)21-2213-14

1,8

0 5mm3

3,2(P)21-2213-14

6,5(A)

0 mm3

15,7(P)21-2213-1421-2213-14

3,1(A)21-2213-1421-2213-14

0 mm1,5

7,8(P)1,8

0 5mm0,9

4,5(P)21-2213-1421-2213-14

1,8

0 5mm0,9

4,5(P)21-2213-1421-2213-14

Page 3: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/4 Te

3

Limit switchesDouble insulated, conforming to CENELEC EN 50047, type XCK-PComplete switches with 1 cable entry, tapped M16 x 1.5

References, characteristics, function diagrams, dimensions

Type of operating head Rotary

Thermoplastic roller lever Variable length thermoplastic roller lever

References ( N/C contact with positive opening operation)

2-pole 1 N/C + 1 N/O XCK-P118H29 XCK-P145H29snap action(XES-P2151)

2-pole 1 N/C + 1 N/O XCK-P518H29 XCK-P545H29break before makeslow break (XEN-P2151)

Weight (kg) 0.070 0.080

Complementary characteristics

Switch actuation By 30° cam

Maximum actuation speed 1.5 m/s 1.5 m/s

Mechanical durability 10 million operating cycles

Minimum torque for tripping 0.1 N.m

for positive opening 0.25 N.m

Cable entry 1 entry tapped M16 x 1.5 for ISO cable gland. Clamping capacity : 4 to 8 mm.Function diagramsXCK-P118H29 XCK-P145H29 XCK-P518H29 XCK-P545H29

Contact operation (P) = positive opening pointg contact closedh contact open

DimensionsXCK-Piiiii18H29 XCK-Piiiii45H29

(1) 1 cable entry, tapped M16 x 1.5 for ISO cable gland(2) 115 max.(3) 133 max.Ø : 2 elongated holes Ø 4.3 x 8.3 on 22 centres, 2 holesØ 4.3 on 20 centres

1314 22

21

1314 22

21

25°

0 70°12°

60°(P)21-2213-1421-2213-14

44,5

108

25

5,5 24

40

(1)

30

20/22 ==

Ø

53,5

Ø19

35,5

4

43,5

111,

5...1

57,5

25

5,5 30

38

(1)

58...

103

30

20/22 ==

Ø

Ø19

40...

85

4

25°

0 70°12°

21-2213-1421-2213-14

25°

0 70°35°

46°(P)21-2213-14

25°

0 70°35°

21-2213-14

Page 4: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/5Te

3

1314 22

21

1314 22

21

1,8

0 5mm0,9

4,5(P)21-2213-1421-2213-14

1,8

0 5mm0,9

4,5(P)21-2213-1421-2213-14

6,5(A)

0 mm3

15,7(P)21-2213-1421-2213-14

1,8

0 5mm3

3,2(P)21-2213-14

1,8

0 5mm3

3,2(P)21-2213-14

6,5(A)

0 mm10,5

11,3(P)21-2213-14

3,1(A)21-2213-1421-2213-14

0 mm1,5

7,8(P)

3,1(A)

0 mm5,2

5,6(P)21-2213-14

Limit switchesDouble insulated, CENELEC EN 50047 compatible, type XCK-TComplete switches with 2 cable entries, tapped M16 x 1.5

References, characteristics, function diagrams, dimensions

Type of operating head Plunger

Metal plunger Steel plunger with Thermoplastic Thermoplasticelastomer boot roller plunger roller lever plunger

References ( N/C contact with positive opening operation)

2-pole 1 N/C + 1 N/O XCK-T110H29 XCK-T111H29 XCK-T102H29 XCK-T121H29snap action(XES-P3151)

2-pole 1 N/C + 1 N/O XCK-T510H29 XCK-T511H29 XCK-T502H29 XCK-T521H29break before makeslow break (XEN-P3151)

Weight (kg) 0.065 0.065 0.065 0.070

Complementary characteristics

Switch actuation On end By 30° cam

Maximum actuation speed 0.5 m/s 0.3 m/s 1 m/s

Mechanical durability 15 million 10 million 15 millionoperating cycles operating cycles operating cycles

Minimum force for tripping 15 N 12 N 6 N

for positive opening 45 N 36 N 18 N

Cable entry 2 entries tapped M16 x 1.5 for ISO cable gland. Clamping capacity : 4 to 8 mm.(Switch supplied with 1 entry fitted with blanking plug).

Function diagramsXCK-T110H29 XCK-T111H29 XCK-T102H29 XCK-T121H29

XCK-T510H29 XCK-T511H29 XCK-T502H29 XCK-T521H29

Contact operation (A) = cam displacementg contact closed (P) = positive opening pointh contact open

DimensionsXCK-Tiiiii10H29 XCK-Tiiiii11H29 XCK-Tiiiii02H29 XCK-Tiiiii21H29

(1) 2 cable entries, tapped M16 x 1.5 for ISO cable gland Ø : 4 elongated holes Ø 4.3 x 8.3 on 22/42 centres, 4 holes Ø 4.3 on 20/40 ctrs.

30

8025

12,5

5,5

59,5

40/42

20/22

9,5

==

30,5

Ø11

(1) Ø

4

3,5

30

71,525

12,5

59,5

40/42

20/22

9,5

==

(1) Ø

20

Ø8

4

30

61

25

12,5

30

61

25

12,5

9,5

59,5

40/42

20/22 ==

(1) Ø

20

Ø8

4

Ø

59,5

40/42

20/22

9,5

==

39

Ø14

20

(1)

4

Page 5: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/6 Te

3

1314 22

21

44,5

94,5

5,5 24

40

25

53,535

,5

Ø19

40/42

59,5

20/22

9,5

==

Ø

(1)

413

14 2221

43,5

99...

144

5,5 30

38

25

58...

103

40...

85

Ø19

40/42

59,5

20/22

9,5

==

Ø

(1)

4

Limit switchesDouble insulated, CENELEC EN 50047 compatible, type XCK-TComplete switches with 2 cable entries, tapped M16 x 1.5

References, characteristics, function diagrams, dimensions

Type of operating head Rotary

Thermoplastic roller lever Variable length thermoplastic roller lever

References ( N/C contact with positive opening operation)

2-pole 1 N/C + 1 N/O XCK-T118H29 XCK-T145H29snap action(XES-P3151)

2-pole 1 N/C + 1 N/O XCK-T518H29 XCK-T545H29break before makeslow break (XEN-P3151)

Weight (kg) 0.080 0.090

Complementary characteristics

Switch actuation By 30° cam

Maximum actuation speed 1.5 m/s 1.5 m/s

Mechanical durability 10 million operating cycles

Minimum torque for tripping 0.1 N.m

for positive opening 0.25 N.m

Cable entry 2 entries tapped M16 x 1.5 for ISO cable gland. Clamping capacity 4 to 8 mm.(Switch supplied with 1 entry fitted with blanking plug).

Function diagramsXCK-T118H29 XCK-T145H29 XCK-T518H29 XCK-T545H29

Contact operation (P) = positive opening pointg contact closedh contact open

DimensionsXCK-Tiiiii18H29 XCK-Tiiiii45H29

(1) 2 cable entries, tapped M16 x 1.5 for ISO cable gland (3) 133 max.(2) 115 max. Ø : 4 elongated holes Ø 4.3 x 8.3 on 22/42 centres, 4 holes Ø 4.3 on 20/40 ctrs.

25°

0 70°12°

60°(P)21-2213-1421-2213-14

25°

0 70°35°

46°(P)21-2213-14

25°

0 70°12°

21-2213-1421-2213-14

25°

0 70°35°

21-2213-14

Page 6: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/7Te

3

222113

14XES-P2151

222113

14

Limit switches

Replacement parts for XCK-P and XCK-T limit switches

Replacement contact blocks

Type of contact Scheme For switch Positive Reference Weighttype operation (1) kg

2-pole 1 N/C + 1 N/O XCK-P1iiH29 XES-P2151 0.020snap action

XCK-T1iiH29 XES-P3151 0.015

2-pole 1 N/C + 1 N/O XCK-P5iiH29 XEN-P2151 0.020break before makeslow break

XCK-T5iiH29 XEN-P3151 0.015

(1) : N/C contact with positive opening operation.

XES-P3151

XEN-P2151

XEN-P3151

Page 7: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/8 Te

3

Limit switchesMetal, types XCK-M

General characteristics

Environment

Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14to standards

Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130

Approvals CSA A300, UL A300 Listed, NEMKO FI 10 (4) A-400 V, BV, USSR

Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C

Electric shock protection Class I conforming to IEC 536 and NF C 20-030

Degree of protection IP 66 conforming to IEC 529 ; IP 665 conforming to NF C 20-010

Repeat accuracy 0.05 mm on the tripping points

Cable entry 3 entries, tapped M20 x 1.5For other threaded entries, please consult your Regional customer centre.

Contact block characteristics

Rated operational characteristics ccccc AC-15 ; A300 (Ue = 240 V, Ie = 3 A)aaaaa DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1

Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-1 and VDE 0110, group C conforming toNF C 20-040

Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

Rated withstand impulse voltage U imp = 6 kV conforming to IEC 947-1, IEC 664

Short-circuit protection 10 A cartridge fuse type gG (gl)

Minimum actuation speed XES-P2151 : 0.001 m/minute, XEN-P2151 : 0.001 m/second

Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5

Page 8: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/9Te

3

1314 22

21

1314 22

21

1,8

0 5,5mm0,9

4,5(P)21-2213-1421-2213-14

1,8

0 5,5mm3

3,2(P)21-2213-14

3,1(A)

0 mm1,5

7,8(P)21-2213-1421-2213-14

3,1(A)

0 mm5,2

5,6(P)21-2213-14

4,6(A)

0 mm2,2

11,1(P)21-2213-1421-2213-14

4,6(A)

0 7,6 mm

8(P)21-2213-14

26°

0 70°11°

58°(P)21-2213-1421-2213-14

26°

0 36° 70°

42°(P)21-2213-14

Ø19

34,5

60,5

41

64==

Ø

5,5

22 15

119

30

34

(1)

8

8

14

112,

5

30(1)

Ø20

54

Ø

41

65

11,5

Ø

Ø12

48,5

41

64==

4

14

108

30

(1)

Ø10

41

64

30

Ø

==

88,5

30

14

(1)

Limit switchesMetal, type XCK-MComplete switches with 3 cable entries, tapped M20 x 1.5

References, characteristics, function diagrams, dimensions

Type of operating head Plunger Rotary

Metal plunger Steel roller plunger Thermoplastic Thermoplasticroller lever plunger roller lever

References ( N/C contact with positive opening operation)

2-pole 1 N/C + 1 N/O XCK-M110H29 XCK-M102H29 XCK-M121H29 XCK-M115H29snap action(XES-P2151)

2-pole 1 N/C + 1 N/O XCK-M510H29 XCK-M502H29 XCK-M521H29 XCK-M515H29break before makeslow break (XEN-P2151)

Weight (kg) 0.250 0.255 0.300 0.280

Complementary characteristics

Switch actuation On end By 30° cam

Maximum actuation speed 0.5 m/s 1.5 m/s

Mechanical durability 20 million operating cycles 15 millionoperating cycles

Minimum force for tripping 15 N 12 N 8 N 0.1 N.mor torque

for positive opening 45 N 36 N 24 N 0.25 N.m

Cable entry 3 entries tapped M20 x 1.5 for ISO cable gland. Clamping capacity : 7 to 13 mm.(Switch supplied with 2 entries fitted with blanking plugs).

Function diagramsXCK-M110H29 XCK-M102H29 XCK-M121H29 XCK-M115H29

XCK-M510H29 XCK-M502H29 XCK-M521H29 XCK-M515H29

Contact operationg contact closed (A) = cam displacementh contact open (P) = positive opening point

DimensionsXCK-Miiiii10H29 XCK-Miiiii02H29 XCK-Miiiii21H29 XCK-Miiiii15H29

(1) 3 cable entries, tapped M20 x 1.5 for ISO cable gland (2) 2 x Ø 4 H 11, depth 10 Ø : 2 elongated holes Ø 5.2 x 6.2

Page 9: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/10 Te

3

Limit switchesMetal, compact, type XCM

General characteristics

Environment

Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, NF C 63-145 Class Y2, VDE 0660-200, UL 508,to standards CSA C22-2 n° 14

Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130

Approvals Special version : XCM-A : CSA A150, and UL Recognized B300

Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C

Electric shock protection Class I conforming to IEC 536 and NF C 20-030

Degree of protection IP 67 conforming to IEC 529 ; IP 675 conforming to NF C 20-010

Repeat accuracy 0.05 mm on the tripping points

Contact block characteristics

Rated operational characteristics ccccc AC-15 ; B300 (Ue = 240 V, Ie = 1.5 A)aaaaa DC-13 ; R300 (Ue = 250 V, Ie = 0.1 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1

Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-5-1 and VDE 0110, group C conforming toNFC 20-040

Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

Rated impulse withstand voltage U imp = 4 kV conforming to IEC 947-1, IEC 664

Short-circuit protection 6 A cartridge fuse type gG (gl)

Cabling Pre-cabled, 5 x 0.75 mm2

Minimum actuation speed 0.002 m/minute

Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5

Page 10: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/11Te

3

Limit switchesMetal, compact, type XCMComplete switches, pre-cabled

References, characteristics, function diagrams, dimensions

Type of operating head Plunger Rotary Plunger

Metal Steel plunger Steel roller Thermo- Metal Metal plunger Steel rollerplunger with elastomer plunger plastic plunger with elastomer plunger

boot roller lever boot

References

Single-pole 1 C/O Fixing by the body Fixing by the headsnap action (1)

XCM-A110 XCM-A111 XCM-A102 XCM-A115 XCM-F110 XCM-F111 XCM-F102

Weight (kg) 0.240 0.240 0.245 0.245 0.260 0.260 0.265

Complementary characteristics

Switch actuation On end By 30° cam On end By 30° cam

Maximum actuation speed 0.5 m/s 0.1 m/s 1.5 m/s 0.5 m/s 0.1 m/s

Mechanical durability 10 million operating cycles

Minimum force for tripping 7.5 N 5 N 0.05 N.m 7.5 N 4.5 Nor torque

for positive opening 37.5 N 25 N 0.15 N.m 37.5 N 22 N

Cabling PVC cable, 5 x 0.75 mm2, length 1 metre.For other cable lengths and special cables, please consult your Regional customer centre.

(1) Also available with gold flashed contacts, please consult your Regional customer centre.Function diagramsXCM-A110 XCM-A111 XCM-A102 XCM-A115 XCM-F110, XCM-F111 XCM-F102

Contact operation : g contact closed, h contact open (A) = cam displacement (P) = positive opening point

DimensionsXCM-A110 XCM-A111 XCM-A102

XCM-A115 XCM-F110 XCM-F111 XCM-F102

Ø : 2 fixing holes Ø 4.3, counterbored Ø 8.2 x 4 mm deep. G : Fixing by upper part of the body : 2 tapped holes M3, on 18 mm centres Ø 12.5 panel cut-out for passage of operating head. Maximum panel thickness : 5 mm.(1) Pre-cabled, Ø 8 x 1 m length. (2) XCM-A11i. E : 8 mm max., panel cut-out Ø 12.5 mm. F : 8 mm max., panel cut-out Ø 16.5 mm.

BK

-WH

B

K

BN

BU

GN YE

2,6(A)

0 mm0,9

BK-BKBN-BUBK-BKBN-BU

1,5

0 5mm0,5

BK-BKBN-BUBK-BKBN-BU

20°

0 70°9°

BK-BKBN-BUBK-BKBN-BU

2,6(A)BK-BKBN-BUBK-BKBN-BU

0 mm0,9

1,5

0 5mm0,5

BK-BKBN-BUBK-BKBN-BU

1,5

0 5mm0,5

BK-BKBN-BUBK-BKBN-BU

30

40

20±0,1 (1)

Ø14

52

33

Ø

16

30

49

92

5,5

24(2)

16 30

51(1)

23,7

16

74,7

Ø8

E

M12x1

30

51(1)

37

Ø16

16

86

Ø8

F

M6x1

30

51(1)

35,4

Ø10,6

16

86,4

4

E

M12x1

16

49 59,8

Ø8

30

19,8

Ø12

G

40

Ø

(1)20±0,1

30

29,8

(1)

40

Ø

20±0,1

G

16

49

69,8

Ø8

20±0,1

30

4030

(1)

Ø

Ø12 G

16

49

70

4

Page 11: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/12 Te

3

Limit switchesDouble insulated, conforming to CENELEC EN 50041, type XCK-S

General characteristics

Environment

Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14to standards

Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130

Approvals Standard version : NEMKO FI 10 (4) A-400 V

Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C

Electric shock protection Class II conforming to IEC 536 and NF C 20-030

Degree of protection IP 65 conforming to IEC 529 ; IP 653 conforming to NF C 20-010

Repeat accuracy 0.05 mm on the tripping points

Cable entry 1 entry, tapped M20 x 1.5For other threaded entries, please consult your Regional customer centre.

Contact block characteristics

Rated operational characteristics ccccc AC-15 ; A300 (Ue = 240 V, Ie = 3 A)aaaaa DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1

Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-1 and VDE 0110, group C conforming toNF C 20-040

Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

Rated withstand impulse voltage U imp = 6 kV conforming to IEC 947-1, IEC 664

Short-circuit protection 10 A cartridge fuse type gG (gl)

Minimum actuation speed XES-P2151 : 0.001 m/minute, XEN-P2151 : 0.001 m/second

Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5

Page 12: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/13Te

3

Limit switchesDouble insulated, conforming to CENELEC EN 50041, type XCK-SComplete switches with 1 cable entry, tapped M20 x 1.5

References, characteristics, function diagrams, dimensions

Type of operating head Plunger Rotary

Metal plunger Steel roller plunger Thermoplastic Variable length elastomerroller lever roller lever

References ( N/C contact with positive opening operation)

2-pole 1 N/C + 1 N/O XCK-S101H29 XCK-S102H29 XCK-S131H29 XCK-S149H29snap action(XES-P2151)

2-pole 1 N/C + 1 N/O XCK-S501H29 XCK-S502H29 XCK-S531H29 XCK-S549H29break before makeslow break (XEN-P2151)

Weight (kg) 0.095 0.105 0.145 0.155

Complementary characteristics

Switch actuation On end By 30° cam

Maximum actuation speed 0.5 m/s 1.5 m/s

Mechanical durability 25 million 15 million 20 millionoperating cycles operating cycles operating cycles

Minimum force for tripping 15 N 12 N 0.15 N.m

for positive opening 45 N 36 N 0.3 N.m

Cable entry 1 entry tapped M20 x 1.5 for ISO cable gland. Clamping capacity : 7 to 13 mm.Function diagramsXCK-S101H29 XCK-S102H29 XCK-S131H29 XCK-S149H29

XCK-S501H29 XCK-S502H29 XCK-S531H29 XCK-S549H29

Contact operation (A) = cam displacementg contact closed (P) = positive opening pointh contact open

DimensionsXCK-Siiiii01H29 XCK-Siiiii02H29 XCK-Siiiii31H29 XCK-Siiiii49H29

(1) 1 cable entry, tapped 20 mm ISO Ø : 2 elongated holes Ø 5.3 x 7.3

36

29,5

103

(1)

16

2xØ5,3

40

30= =

6036

,5

Ø10

Ø

116

16

4

36

29,5

(1)

Ø

6049

,5

Ø12

2xØ5,3

40

30= =

132,

5...1

87,5

58

10

57

29,5

(1)

40

30= =

6067

...12

1,5

45...

99,5

Ø50

Ø

2xØ5,3

60

29,5

129

55

6 39

(1)

40

30= =

6063

41

Ø22

2xØ5,3

Ø

1314 22

21

1314 22

21

1,8

0 5,5mm0,9

4,5(P)21-2213-1421-2213-14

3,1(A)

0 mm1,5

7,8(P)21-2213-1421-2213-14

23°

0 80°11°

58°(P)21-2213-1421-2213-14

23°

0 80°11°

21-2213-1421-2213-14

1,8

0 5,5mm3

3,2(P)21-2213-14

3,1(A)

0 mm5,2

5,6(P)21-2213-14

23°

0 80°33°

42°(P)21-2213-14

23°

0 80°33°

21-2213-14

Page 13: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/14 Te

3

Limit switchesMetal, conforming to CENELEC EN 50041, type XCK-J

General characteristics

Environment

Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14to standards

Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130

Approvals CSA A300, UL A300 Listed, NEMKO FI 10 (4) A-400 V, GL, BV, USSR

Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °CSpecial sub-assemblies available for extreme operating temperatures (- 40 °C and + 120 °C). Pleaseconsult your Regional Sales Office.

Electric shock protection Class I conforming to IEC 536 and NF C 20-030

Degree of protection IP 66 conforming to IEC 529 ; IP 667 conforming to NF C 20-010

Repeat accuracy 0.01 mm on the tripping points

Cable entry 1 entry, tapped M20 x 1.5For other threaded entries, please consult your Regional customer centre.

Contact block characteristics

Rated operational characteristics ccccc AC-15 ; A300 (Ue = 240 V, Ie = 3 A)aaaaa DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1

Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-1 and VDE 0110, group C conforming toNF C 20-040

Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

Rated impulse withstand voltage U imp = 6 kV conforming to IEC 947-1, IEC 664

Short-circuit protection 10 A cartridge fuse type gG (gl)

Minimum actuation speed XES-P2151 : 0.001 m/minute, XEN-P2151 : 0.001 m/second

Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5

Page 14: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/15Te

3

1314 22

21

1314 22

21

221-2213-1421-2213-14

0

4,7(P)

0,96mm

3,2(A)

0 mm1,5

8,1(P)21-2213-1421-2213-14

23°

0 90°11°

58°(P)21-2213-1421-2213-14

23°

0 90°11°

58°(P)21-2213-1421-2213-14

2

0 6mm3,2

3,4(P)21-2213-14

3,2(A)

0 mm5,3

5,9(P)21-2213-14

23°

0 90°33°

40°(P)21-2213-14

23°

0 90°33°

40°(P)21-2213-14

33,5

17

44

107

(1)

3760

30

40

==

2xØ5,3

Ø

Ø10

5060

30

40

==

2xØ5,3

Ø

Ø12

33,5

17

44

120

(1)

5

62…

107

60

30

40

==

2xØ5,3

Ø

Ø19

40…

85

33,5

52

60

5,5

132…

177

(1)

44

6360

30

40

==

2xØ5,3

Ø

Ø22

41

33,5

57

62

5

133

(1)

41

(switches supplied for actuationfrom left AND right)

Limit switchesMetal, conforming to CENELEC EN 50041, type XCK-JComplete switches, fixed body1 cable entry, tapped M20 x 1.5

References, characteristics, function diagrams, dimensions

Type of operating head Plunger Rotary

Metal plunger Steel roller plunger Thermoplastic Variable length thermo-roller lever plastic roller lever

References ( N/C contact with positive opening operation)

2-pole 1 N/C + 1 N/O XCK-J161H29 XCK-J167H29 XCK-J10511H29 XCK-J10541H29snap action(XES-P2151)

2-pole 1 N/C + 1 N/O XCK-J561H29 XCK-J567H29 XCK-J50511H29 XCK-J50541H29break before makeslow break (XEN-P2151)

Weight (kg) 0.430 0.455 0.480 0.485

Complementary characteristics

Switch actuation On end By 30° cam

Maximum actuation speed 0.5 m/s 1 m/s 1.5 m/s

Mechanical durability 30 million 25 million 30 millionoperating cycles operating cycles operating cycles

Minimum force for tripping 20 N 16 N 0.25 N.mor torque

for positive opening 50 N 40 N 0.50 N.m

Cable entry 1 entry tapped M20 x 1.5 for ISO cable gland. Clamping capacity : 7 to 13 mm.Function diagramsXCK-J161H29 XCK-J167H29 XCK-J10511H29 XCK-J10541H29

XCK-J561H29 XCK-J567H29 XCK-J50511H29 XCK-J50541H29

Contact operation (A) = cam displacementg contact closed, h contact open (P) = positive opening point

DimensionsXCK-Jiiiii61H29 XCK-Jiiiii67H29 XCK-Jiiiii0511H29 XCK-Jiiiii0541H29

(1) 1 cable entry, tapped M20 x 1.5 for ISO cable gland Ø : 2 elongated holes Ø 5.3 x 7.3

Page 15: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/16 Te

3

Limit switchesMetal, type XC2-J

General characteristics

Environment

Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14to standards

Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130

Approvals Standard version : DEMKO, NEMKO, CSA 300 V a HD, c 60 WSpecial version : UL 250 V c HD Listed, CSA 300 V c HD, 60 W with 1/2" NPT threaded cable entry

Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C

Electric shock protection Class I conforming to IEC 536 and NF C 20-030

Degree of protection IP 65 conforming to IEC 529 ; IP 657 conforming to NF C 20-010

Repeat accuracy 0.01 mm on the tripping points

Cable entry 1 entry, incorporating cable gland. Clamping capacity : 6 to 13.5 mm

Contact block characteristics

Rated operational characteristics ccccc AC-15 ; A300 (Ue = 240 V, Ie = 3 A)aaaaa DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1

Rated insulation voltage 500 V conforming to IEC 947-5-1, group C conforming to NF C 20-040300 V conforming to CSA C22-2 n° 14

Short-circuit protection 10 A cartridge fuse type gG (gl)

Minimum actuation speed 0.001 m/minute

Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5

Page 16: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/17Te

3

121113

14

XCK-Z01 121113

14

Limit switchesMetal, type XC2-JComplete switches, fixed body, 1 cable entry incorporating cable gland

References, characteristics, function diagrams, dimensions

Type of operating head Plunger Rotary

Metal plunger Steel roller plunger Thermoplastic Variable length thermoplasticroller lever roller lever

References

Actuation from left AND rightSingle-pole 1 C/O XC2-JC161H29 XC2-JC162H29 XC2-JC10111H29 XC2-JC10131H29snap action Actuation from left OR right(XCK-Z01) XC2-JC10511H29 XC2-JC10531H29

Weight (kg) 0.555 0.560 0.605 0.620

Complementary characteristics

Switch actuation On end By 30° cam By 30° cam

Maximum actuation speed 0.5 m/s 1.5 m/s

Mechanical durability 30 million 25 million 30 millionoperating cycles operating cycles operating cycles

Minimum force or torque for tripping 18 N XC2-JC101ii H29: 0.30 N.m ; XC2-JC105iiH29 : 0.20 N.m

Cable entry 1 tapped entry incorporating metal cable gland. Clamping capacity : 6 to 13.5 mm.Function diagramsXC2-JC161H29 XC2-JC162H29 XC2-JC10111H29, XC2-JC10511H29 XC2-JC10131H29, XC2-JC10531H29

Contact operation (A) = cam displacementg contact closed, h contact open (P) = positive opening point

DimensionsXC2-JC161H29 XC2-JC162H29 XC2-JC10111H29, XC2-JC10511H29 XC2-JC10131H29, XC2-JC10531H29

(1) Fixing from the rear : by 2 M5 screwsDepth of thread : 10 mm

Ø : Fixing from the front via 2 holes Ø 5.5 Cable gland incorporated (all XC2-JC models)

Replacement contact block

Type Scheme Reference Weightkg

Single-pole 1 C/O XCK-Z01 0.050snap action

1,4

0 5mm0,5

11-1213-1411-1213-14

2,4 (A)

0 mm0,9

11-1213-1411-1213-14

12°11-1213-1411-1213-14

0 75°6°

12°

0 75°6°

11-1213-1411-1213-14

6047

Ø12

40

29= =

Ø

(1)

121

41

24

19,5

24

65

143.

..183

5

39…71

40

29= =

Ø

(1)

6069

...10

9

46...

86

Ø22

24

65

141

5

41…39

40

29= =

67

44

Ø 22

Ø

(1)

606059

Ø12

40

29= =

Ø

(1)133

19,5

4

41

24

Page 17: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/18 Te

3

Limit switchesFor hoisting and mechanical handling, type XCR

General characteristics

Environment

Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14to standards

Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130

Approvals XCR-A standard version : CSA A300, UL A300 Listed, NEMKO FI 10 (4) A-400 V, USSRXCR-A special version : CSA A300, UL A300 Listed 1/2" NPT

Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C

Electric shock protection Class I conforming to IEC 536 and NF C 20-030

Degree of protection IP 54 conforming to IEC 529 ; IP 545 conforming to NF C 20-010

Cable entry 1 entry, tapped for Pg 13.5 cable gland

Contact block characteristics

Rated operational characteristics ccccc AC-15 ; A300 (Ue = 240 V, Ie = 3 A)aaaaa DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1

Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-1 and VDE 0110, group C conforming toNF C 20-040

Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

Rated withstand impulse voltage U imp = 6 kV conforming to IEC 947-1, IEC 664

Short-circuit protection 10 A cartridge fuse type gG (gl)

Minimum actuation speed 0.001 m/minute

Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5

Page 18: Limit switches - Octopartdatasheet.octopart.com/XCKS131H29-Telemecanique... · 3/4 Te 3 Limit switches Double insulated, conforming to CENELEC EN 50047, type XCK-P Complete switches

3/19Te

3

Limit switchesFor hoisting and mechanical handling, type XCRComplete switches with 1 cable entry

References, characteristics, function diagrams, dimensions

Type of operating head Rotary with spring return to off position 55° in each direction

6 mm Thermo- Largesquare plastic thermo-metal roller plasticrod lever roller lever

References ( N/C contact with positive opening operation)

Two 2-pole Both contacts XCR-A11 XCR-A12 XCR-A151 N/C + 1 N/O operate insnap action each direction(XES-P2151)

1st contact 2nd contact

Weight (kg) 1.110 1.145 1.155

Complementary characteristics

Maximum actuation speed 1.5 m/s

Mechanical durability 10 million operating cycles

Minimum torque for tripping 0.45 N.m

for positive opening 0.75 N.m

Cable entry 1 tapped entry for Pg 13.5 cable gland conforming to NF C 68-300. Clamping capacity : 9 to 12 mm.Function diagramsXCR-A11 XCR-A12 XCR-A15

DimensionsXCR-A11 XCR-A12 XCR-A15

(1) 1 cable entry, tapped for Pg 13.5 cable gland (2) Rod length : 200 mm (3) Rod + roller length : 160 mm

Replacement contact block assembly

Description Type Reference Weightkg

Contact block (2 contacts) 2-pole 1 N/C + 1 N/O XCR-Z12 0.135with mounting plate snap action

222113

14222113

14

21-2213-1421-2213-14

5° 5°

016°16°55° 55°

30°(P)30°(P)

21-2213-1421-2213-14

21-2213-1421-2213-14

5° 5°

016°16°55° 55°

30°(P)30°(P)

21-2213-1421-2213-14

21-2213-1421-2213-14

5° 5°

016°16°55° 55°

30°(P)30°(P)

21-2213-1421-2213-14

2nd contact

1st contact

2nd contact

1st contact

2nd contact

1st contact

66

53

75

== 32

95

6 (2)

85

85

==

4xØ5,5

75

(1)

18

==

Ø42

72…60

4

9

53

75

== 32

95

Ø30

(3)

85

85

==

4xØ5,5

75

(1)

18

==

Ø42

9

68

53

75

== 32

95

18

85

78

85

==

4xØ5,5

Ø50

75

(1) ==

102

XCR-Z12