REPEATABILITY If you put a block on a scale the display will read out
the weight. 10
0
9.99
Block WeightBlock Lifted
Block Put Back
When the same block (load), is removed and then is placed back on the scale, the non-repeatability error, will be the possible difference between the same load
Non- Linearity
As the load increases it is ideal for the cell load versus cell output to be linear The error is the amount that the signal out put deviates from linear
values There are multiple methods to compensate and make the relation
more linear and predictable
Creep Over time if a material is under a load and under
environmental conditions (E.G high temperature) it will begin to show slight deformation.
In the sense of load cells if there is a significant load for an extended period of time it is possible that this will show a small error in output
10 10
9.99
6 months2 years
5 years
Hysteresis
Is the difference when coming down to a load versus going up to a load
From one block to two blocks
From four blocks to two blocks
10 9.99
Final Notes The full capacity of the load cell shown is
200,000 The combined error is the calculated error that
the load cell may experience based on all other errors on the Full Scale Output
To be determined from testing will be our own system error: This will be based on possible error cause by our
silo system operations and operator ( E.g. uneven surface)