STACK FRAME Submial Sheet MS-Sub-15 Job Name: __________________________________ Location: __________________________________ Engineer: __________________________________ Agent/Wholesaler: ______________________________ Contractor: __________________________________ NOTES: Model No. __________________________________ Dimensions A: ________ B: ________ C: ________ Equipment Tag(s): _____________________________________________ _____________________________________________ STACK FRAME SUBMITTAL FOR FLOOR MOUNT WATER HEATERS AND BOILERS 01/21—Printed in U.S.A. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com ARMOR ® WATER HEATERS AW 151– AWH1000 KNIGHT ® HEATING BOILERS KHB055–285 KBX0400–1000 FOR PART A* B** C Wt. MODEL NO. (lbs.) AW 151–200 100163408 90-1/2” 26” 26” 60 AW 286 100163409 109” 26” 34” 72 KHB 055–285 AWH/KBX 0400–0500 100341328 116” 34-1/4” 35-3/4” 168 AWH/KBX 0650–0800 100341329 116” 34-1/4” 44-1/2” 182 AWH/KBX 1000 100341330 116” 34-1/4” 52” 195 Pre-Assembled Welded Construction Lochinvar’s technology not only makes our water heaters and boilers more efficient, it means they also have a smaller footprint. So they save space as well as operating costs. And now there’s a way to get greater flexibility and reliability, save even more space, and get a system that’s perfectly matched to a facility–thanks to the use of a Stack Frame from Lochinvar. No Assembly Required Lochinvar’s Stack Frame is fully factory assembled and shipped in one piece. The frame is welded using square steel tubing by certified welders ensuring integrity for the life of the frame. Dimension Notes * “A” (Height) is measured from the base to the top of the upper unit. ** “B” (Width) is the actual frame dimension. Additional clearance is needed for plumbing connections. B A C HEATER HEIGHTS: AW 151–200 33-1/4” AW 286 42-1/2” KHB 055–285 43-1/2” AWH/KBX 0400–1000 45”

Upload: others

Post on 16-Oct-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lochinvar, LLC

STACK FRAME

Submittal Sheet MS-Sub-15

Job Name: __________________________________

Location: __________________________________

Engineer: __________________________________

Agent/Wholesaler: ______________________________

Contractor: __________________________________

NOTES:

Model No. __________________________________

Dimensions A: ________ B: ________ C: ________

Equipment Tag(s):

_____________________________________________

_____________________________________________

STACK FRAME SUBMITTAL FOR FLOOR MOUNT WATER HEATERS AND BOILERS

01/21—Printed in U.S.A.

Lochinvar, LLC 300 Maddox Simpson ParkwayLebanon, Tennessee 37090P: 615.889.8900 / F: 615.547.1000

Lochinvar.com

ARMOR® WATER HEATERSAW 151– AWH1000

KNIGHT® HEATING BOILERSKHB055–285KBX0400–1000

FOR PART A* B** C

Wt. MODEL NO. (lbs.)

AW 151–200 100163408 90-1/2” 26” 26” 60

AW 286 100163409 109” 26” 34” 72 KHB 055–285

AWH/KBX 0400–0500 100341328 116” 34-1/4” 35-3/4” 168

AWH/KBX 0650–0800 100341329 116” 34-1/4” 44-1/2” 182

AWH/KBX 1000 100341330 116” 34-1/4” 52” 195

Pre-Assembled Welded Construction

Lochinvar’s technology not only makes our water heaters and boilers more efficient, it means they also have a smaller footprint. So they save space as well as operating costs. And now there’s a way to get greater flexibility and reliability, save even more space, and get a system that’s perfectly matched to a facility–thanks to the use of a Stack Frame from Lochinvar.

No Assembly Required

Lochinvar’s Stack Frame is fully factory assembled and shipped in one piece. The frame is welded using square steel tubing by certified welders ensuring integrity for the life of the frame.

Dimension Notes

* “A” (Height) is measured from the base to the top of the upper unit.

** “B” (Width) is the actual frame dimension. Additional clearance is needed for plumbing connections.

B

A

C

HEATER HEIGHTS:

AW 151–200 33-1/4”

AW 286 42-1/2”

KHB 055–285 43-1/2”

AWH/KBX 0400–1000 45”

Page 2: Lochinvar, LLC

COPPER-FIN® WATER HEATERS & BOILERS

CB/CW 497-747

SOLUTIONTM BOILERSCB 045-260

COPPER-FIN® WATER HEATERS & BOILERS

CB 315-500CW 090-500

FOR PART A* B** C Wt. MODEL NO. (lbs.) CB 045 CB 075 CB/CW 090 100163398 65” 36” 39” 73 CB/CW 135 CB/CW 180 CW 199 CB 215 CW 225 CB 260 100163400 65” 48” 39” 84 CW 270 CB/CW 315 CB/CW 360 CB/CW 399 100163401 65” 66” 39” 147 CB/CW 500 100163401 70” 66” 39” 147Note: Heater height is 29-1/2” (45 - 399) and 34-1/2” (500).

FOR PART A* B** C

Wt. MODEL NO. (lbs.)

CB/CW 497 100163366 81-3/4” 53” 24-1/2” 70 CB/CW 647 100163370 84-3/4” 73” 25” 128 CB/CW 747 Note: Heater height is 33-1/4” (497-747)

FOR PART A* B** C Wt. MODEL NO. (lbs.) CH/CF 402

100163385 67-1/2” 59” 24-1/2” 83 CH/CF 502 CH/CF 652

100163387 67-1/2” 80” 24-1/2” 132 CH/CF 752 CB/CW/CH/CF 987/992 100163373 80” 75” 36” 170 CB/CW/CH/CF 1257/1262

100163374 80” 95” 36” 214 CB/CW/CH/CF 1437/1442 CB/CW/CH/CF 1797/1802

100163376 80” 119” 36” 251 CB/CW/CH/CF 2067/2072 Note: Heater height is 31-1/2” (402-752) & 36” (987-2072)

COPPER-FIN® WATER HEATERS & BOILERSCB/CW 987-2067

COPPER-FIN II® WATER HEATERS & BOILERSCF/CH 402-2072

B

A

C

C

A

B

B

A

C

* “A” (Height) is measured from the base to the vent connection on the upper unit.

** “B” (Width) is the actual frame dimension. Additional clearance is needed for plumbing connections.