lottes 1st floor renovation phase oneoperations-webapps.missouri.edu/pdc/adsite/... · nfpa 20...
TRANSCRIPT
-
SITE
HOSPITAL DR
E S
TADIU
M BLV
D
TIG
ER
AV
E
DE
AN
S D
R
KENTUCKY BLVD
(1) CONTRACTOR PARKING SPOT ADJACENT TO GENERATOR
(1) CONTRACTOR PARKING SPOT IN LOT WG1/L
NOTE: ADDITIONAL PARKING - REFER TO SPECIFICATIONS
GENERAL NOTES & SYMBOLS
011/8" = 1'-0"A201 A501
VIEW NAME
ASI02
X1
01
STRUCTURAL GRID
LEVEL MARKER
SPOT ELEVATION
100'-0"
BUILDING SECTION
WALL SECTION
DETAIL SECTION
A5011
1A301
INTERIOR ELEVATION
BUILDING ELEVATION
WALL TAG
DOOR TAGNEW WORK KEYNOTE
DEMOLITION KEYNOTE
REVISION TAGTRUE NORTH ARROW
REFERENCING SHEET
DRAWING SHEET
OCCUPANT LOAD
100
A0000
C
01A2
1
A101
SIM
1
A101
SIM
1
A101
SIM
NameElevation
I HEREBY CERTIFY THESE DRAWINGS AND/ OR SPECIFICATIONS HAVE BEEN PREPARED BY ME, OR UNDER MY SUPERVISION. I FURTHER CERTIFY THAT TO THE BEST OF MY KNOWLEDGE THESE DRAWINGS AND/ OR SPECIFICATIONS ARE AS REQUIRED BY AND IN COMPLIANCE WITH THE BUILDING CODES OF THE UNIVERSITY OF MISSOURI.
SIGNATURE:
CLINICAL SUPPORT EDUCATION BLDG
TIG
ER
AV
E LOTTES HEATH SCIENCES LIBRARY
PATIENT CENTERED
CARE LEARNING
CENTER - NO CONTRACTOR
ACCESS
CLINICAL SUPPORT EDUCATION BLDG
MED SCIENCE ADDITION
COOLING TOWER CLINICAL
SUPPORT AND
EDUCATION
MED SCIENCE
PROJECT LOCATION
CONTRACTOR LAY DOWN AREA, COORDINATE ACCESS TO AREA WITH OWNER AND CONTRACTOR FOR SCHOOL OF NURSING RENOVATION
25'-0"
20
'-0
"
LAY DOWN AREA FOR SCHOOL OF NURSING PROJECT, WHICH WILL BE CONSTRUCTED CONCURRENTLY WITH THIS PROJECT - INCLUDED FOR REFERENCE
NO CONTRACTOR ACTIVITY EAST OF DOUBLE DOORS
PROJECT AREA OF WORK - 1ST FLOOR
CONTRACTOR ENTRY / EXIT TO BUILDING
10'-0"
THIS AREA OF COURTYARD AVAILABLE FOR PALETTES / CRATES OF MATERIAL STORAGE OR DELIVERY. AVOID AND PROTECT TREE GRATES AND PLANTERS.
AREA AVAILABLE FOR DUMPSTER -MAINTAIN CLEARANCES FROM BUILDINGS AS SHOWN
CONTRACTOR DROP OFF AREA
(1) CONTRACTOR PARKING SPOT ADJACENT TO GENERATOR
CROWDER
TWO WAY ROUTE FOR CONSTRUCTION SITE ACCESS
GATE FOR SCHOOL OF NURSING CONSTRUCTION PROJECT -COORDINATE GATE ACCESS W/ OWNER
16
'-0
".
DE
AN
S D
RIV
E
NO CONTRACTOR ACCESS WEST OF THIS SPACE
KENTUCKY BLVD
EXISTING FENCED IN CONTRACTOR AREA
RESTROOMS AVAILABLE FOR CONTRACTOR USE
EXISTING ELECTRICAL TRANSFORMER - MAINTAIN 3' CLEARANCE ON ALL SIDES
GENERAL
G001 COVER SHEET
G002 CODE SHEET
ARCHITECTURAL
A101 FIRST FLOOR DEMO PLAN
A102 FIRST FLOOR DEMO REFLECTED CEILING PLAN
A201 FIRST FLOOR PLAN
A202 FIRST FLOOR REFLECTED CEILING PLAN
A203 SECOND FLOOR DEMO + NEW WORK PLANS
A501 INTERIOR ELEVATIONS
A701 ROOM FINISH SCHEDULES & FINISH PLAN
A702 DOOR FINISH SCHEDULES
PLUMBING
DP101 FIRST FLOOR PLUMBING DEMOLITION PLAN
PS101 FIRST FLOOR SANITARY SEWER AND VENT PLAN
PW101 FIRST FLOOR WATER PIPING PLAN
P501 PLUMBING DETAILS AND SCHEDULES
MECHANICAL
MD101 FIRST FLOOR HVAC DEMOLITION PLAN
MD102 FIRST FLOOR HYDRONIC DEMOLITION PLAN
M101 FIRST FLOOR HVAC PLAN
M102 FIRST FLOOR HYDRONIC PLAN
M501 HVAC DETAILS
M502 HVAC DETAILS
M601 HVAC SCHEDULES
ELECTRICAL
DE101 FIRST FLOOR POWER DEMOLITION PLAN
DE201 FIRST FLOOR LIGHTING DEMOLITION PLAN
EP101 FIRST FLOOR POWER PLAN
EL101 FIRST FLOOR LIGHTING PLAN
E501 ELECTRICAL DETAILS
E601 ELECTRICAL SCHEDULES
FIRE ALARM
DFA101 FIRST FLOOR FIRE ALARM DEMOLITION PLAN
FA101 FIRST FLOOR FIRE ALARM SYSTEM PLAN
FP101 FIRE PROTECTION
ARCHITECT:
2801 Woodard Drive, Suite 103
Columbia, MO 65202
phone: 573.443.1407
FOR THE CURATORS OF THE UNIVERSITY OF MISSOURI
3/1
3/2
02
0 3
:44:1
6 P
M
G0
01
SO
A P
RO
JE
CT
19054
CO
VE
R S
HE
ET
CP
2006
71
Lo
tte
s 1
st
Flo
or
Ren
ov
ati
on
Ph
ase
On
eC
LIE
NT
PR
OJE
CT
NO
. C
P200671
CP200671Lottes 1st Floor Renovation Phase One
9 Hospital DrBuilding #37144Columbia, MO
ISSUE FOR: BID MARCH 19, 2020
MEP ENGINEER: TIMBERLAKE ENGINEERING
912 Old 63 South
Columbia, MO 65201
phone: 573.875.4365
NO SCALEG001
01 LOCATION MAP + CONTRACTOR PARKING
1" = 80'-0"G001
02 SITE PREMIESES / CONSTRUCTION STAGING
-
1 2 3 4 5 6 7 8
A
B
C
D
E
TX
ANESTHESIOLOGY OFFICE SUITEB (BUSINESS) USE
DARK GRAY AREA: 2541 SF / 150 SF PER OCCUPANT (GROSS) = 17 OCCUPANTSEXISTING CONF. ROOM INCLUDED IN "B" OCCUPANT LOAD PER IBC 303.1.2.
1 EXIT REQUIRED
ALLOWABLE EXIT ACCESS TRAVEL DISTANCE: 300'ACTUAL EXIT ACCESS TRAVEL DISTANCE: 160'
SCHOOL OF MEDICINE OFFICES, RESTROOMS, BREAK ROOMB (BUSINESS) USE
CROSS HATCHED AREA: 4242 SF / 150 SF PER OCCUPANT (GROSS) = 29 OCCUPANTSEXISTING BREAK ROOM & CLASSROOM ARE INCLUDED IN "B" OCCUPANT LOAD PER IBC 303.1.2.
1 EXIT REQUIRED
ALLOWABLE EXIT ACCESS TRAVEL DISTANCE: 300'ACTUAL EXIT ACCESS TRAVEL DISTANCE: 202'
EXISTING LIBRARYA-3 (ASSEMBLY) USE
LIGHT GRAY AREA: 7636 SF / 15 SF PER OCCUPANT (NET) = 510 OCCUPANTSEXISTING COMBINED EXIT CAPACITY = 540 OCCUPANTS
3 EXITS REQUIRED3 EXITS PROVIDED
ALLOWABLE COMMON PATH OF EGRESS: 75'ACTUAL COMMON PATH OF EGRESS: 38'
ALLOWABLE EXIT ACCESS TRAVEL DISTANCE: 250'ACTUAL EXIT ACCESS TRAVEL DISTANCE: 110'EXIT CAPACITY: 160
LOAD: 160
EXIT CAPACITY: 220LOAD: 190
EXIT CAPACITY: 160LOAD: 160
EXIT CAPACITY: 160LOAD: 17
EXIT CAPACITY: 160LOAD: 29
EXISTINGATRIUM* OPEN TO 2ND & 3RD FLOORS ABOVE
F.E.F.E.
2 HR RATED
5'-6
".
* ATRIUM NOTE: THE 2020 FEASIBILITY STUDY FOR THE FIRST FLOOR OF LOTTES LIBRARY RECOMMENDS THE EXTENSION OF THE SECOND FLOOR ACROSS THE EXISTING ATRIUM IN A FUTURE RENOVATION, REDUCING THE NUMBER OF COMMUNICATING STORIES IN THE ATRIUM FROM THREE TO TWO.
EDGE OF EXISTING SOFFIT / ATRIUM ABOVE
EXISTING F.E.
1 HR RATED FIRE BARRIER
* DEAD-END CORRIDOR
NOTE: 2018 IBC 1020.4 ( DEAD-END CORRIDOR LIMITS) DO NOT APPLY TO THE NEW SUITES AS BOTH CONTAIN FEWER THAN 49 OCCUPANTS (PER 2018 IBC 1006.2.1)
PROJECT DESCRIPTIONRENOVATION OF A 6,968 SF PORTION OF THE FIRST FLOOR OF LOTTES HEALTH SCIENCES LIBRARY FROM LIBRARY STUDY SPACE AND LIBRARY OFFICES INTO SCHOOL OF MEDICINE OFFICES.
CODES OF RECORD:INTERNATIONAL BUILDING CODE – 2018 INTERNATIONAL PLUMBING CODE - 2018 INTERNATIONAL MECHANICAL CODE – 2018 INTERNATIONAL EXISTING BUILDING CODE – 2018 (LEVEL 1 & LEVEL 2 ALTERATIONS ONLY WITH PRE-APPROVAL OF AHJ) INTERNATIONAL FIRE CODE - 2018 INTERNATIONAL FUEL GAS CODE - 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE - 2018NATIONAL ELECTRIC CODE/NFPA 70 – 2017 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS - 2016 NFPA 96 STANDARD FOR VENTILATING CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS - 2017 NFPA 90A INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS - 2018 NFPA 72 NATIONAL FIRE ALARM CODE – 2016 NFPA 51B STANDARD FOR FIRE PREVENTION DURING WELDING, CUTTING, AND OTHER HOT WORK - 2014NFPA 45 STANDARD ON FIRE PROTECTION FOR LABORATORIES USING CHEMICALS –2015 NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY FIRE PUMPS FOR FIRE PROTECTION – 2016 NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE, PRIVATE HYDRANTS AND HOSE SYSTEMS - 2016 NFPA 13 INSTALLATION OF FIRE SPRINKLER SYSTEMS – 2016 ASHRAE 90.1 – ENERGY STANDARD FOR BUILDINGS – 2016 ASME A17.1 – SAFETY CODE FOR ELEVATORS AND ESCALATORS (PER STATE OF MISSOURI) AMERICANS WITH DISABILITIES ACT – STANDARDS FOR ACCESSIBLE DESIGN 2010
LOTTES NON-COMPLIANT EXISTING CONDITIONS - ATRIUM CONNECTING THREE STORIES (OUTSIDE WORK AREA FOR THIS PROJECT)- RATED STAIR TOWERS HAVE PENETRATIONS THAT ARE NOT ADEQUATELY SEALED AND EXISTING AREA OF REFUGE MAY NOT BE SIZED APPROPRIATELY
LOTTES BUILDING OCCUPANCY CLASSIFICATIONSLEVEL 1 BUSINESS (B) & ASSEMBLY (A-3), NON-SEPARATEDLEVEL 2 ASSEMBLY (A-3)LEVEL 3 ASSEMBLY (A-3)
LOTTES FIRE SUPPRESSIONEXISTING BUILDING IS FULLY SPRINKLERED
LOTTES BUILDING AREALEVEL 1 PROJECT AREA 6,968 SF
TOTAL AREA LEVEL 1 18,151 SFTOTAL AREA LEVEL 2 17,180 SFTOTAL AREA LEVEL 3 17,180 SF
TOTAL PERCENT OF RECONFIGURATION ON LEVEL 1: 38.4%TOTAL PERCENT OF RECONFIGURATION OF ENTIRE LOTTES BUILDING: 15%
LOCAL FIRE DEPARTMENTCITY OF COLUMBIA, MISSOURI
LOCAL AGENCIES HAVING JURISDICTION UM DIRECTOR OF FACILITIES PLANNING AND DEVELOPMENT, UNIVERSITY OF MISSOURI
BUILDING CODES REVIEWA. DEFERRED SUBMITTALS (2018 IBC 107.3.4.1)
• FIRE SPRINKLER SYSTEM• FIRE ALARM SYSTEM
B. USE GROUP (Chapter 3 IBC):• BUSINESS (B) “PROFESSIONAL OFFICES”• ASSEMBLY (A-3) “LIBRARY”
MEANS OF EGRESS - REFER TO CODE PLANA. CORRIDORS:
• FIRE RESISTANCE RATING NOT REQUIRED PER IBC 1020.1 • MINIMUM REQUIRED WIDTH 44 INCHES, PROVIDED 46 INCHES, PER IBC
1020.2• EXIT ACCESS TRAVEL DISTANCE (IBC 1017.2):
1. BUSINESS OCCUPANCY: MAXIMUM W/ SPRINKLERS 300'2. ASSEMBLY OCCUPANCY: MAXIMUM W/ SPRINKLERS 250'
• COMMON PATH OF TRAVEL MAXIMUM (IBC 1006.2.1): 1. BUSINESS OCCUPANCY: MAXIMUM W/ SPRINKLER 100' 2. ASSEMBLY OCCUPANCY: MAXIMUM W/ SPRINKLER 75'
• DEAD END CORRIDORS MAXIMUM (IBC 1020.4) WHEN MORE THAN ONE EXIT IS REQ'D:
1. BUSINESS OCCUPANCY: MAXIMUM W/ SPRINKLER 50' 2. ASSEMBLY OCCUPANCY: MAXIMUM W/ SPRINKLER 20'
PLUMBING FACILITIES PROVIDED - FIRST FLOOR
WATER CLOSETS
RATIO (M)
OCC. LOAD(USE / SEX)
USEMALE FEMALE RATIO MALE FEMALE
1:25 FOR FIRST 50,
THEN 1 PER 50
LAVATORIESSERVICE
SINKS
REQUIREDB
1 1 1 1
1:40 FOR FIRST 80,
THEN 1 PER 80
DRINKING FOUNTAIN
TOTAL PROVIDED
1 1 1 1 1 2
46 / 23 1:100(1 TOTAL)
1 2 3 4 5 6 7 8
A
B
C
D
E
INSTALL TEMPORARY RETURN DUCT ABOVE CEILING LINE BEFORE INITIATING ANY DUST PRODUCING ACTIVITIES - REF MEP. PATCH WALL PENETRATIONS CREATED FOR TEMPORARY DUCT INSTALLATION AFTER REMOVED.
ELEVATOR - NO CONTRACTOR ACCESS
OWNER TO REMOVE ALL EXISTING CARPET AND MOISTURE MITIGATION SHEET PRODUCT BEFORE START OF
CONSTRUCTION ON-SITE. CONTRACTOR TO CLEAN FLOORS AS
NEEDED TO INSTALL NEW CARPET
CONSTRUCT TEMPORARY PLYWOOD ENTRY AT THIS LOCATION TO PROVIDE INCREASED ACCESS TO WORK AREA. PLYWOOD DOOR TO BE LOCKED W/ CAMPUS - PROVIDED PADLOCK WITH MECHANICAL CORE
INITIAL WORK AREA ACCESS TO BE VIA EXISTING DOOR IN THIS LOCATION
STICKY MAT
PLASTIC PARTITION & DUST CONTROL MEASURES TO BE CONFIRMED W/ OWNER / I.T. PRIOR TO WORK IN TELECOM ROOM
INSTALL VERTICAL & HORIZONTAL (OVERHEAD)
PLASTIC DUST BARRIER WHILE DUST PRODUCING ACTIVITIES
OCCUR IN THIS AREA
MASONITE FLOOR PROTECTION -TAPE CONTINUOUS ALONG ALL
EDGES
IF ALT #1 IS REJECTED, PROTECT EXISTING FLOORING THIS AREA WITH MASONITE
CONSTRUCT WALLS SEPARATING LIBRARY FROM OFFICES BEFORE BEGINNING DEMOLITION OR CONSTRUCTION WITHIN WORK AREA
CONSTRUCT, AND COMPLETE ALL FINISH
WORK ON LIBRARY SIDE, OF THE WALLS
SEPARATING LIBRARY FROM OFFICES BEFORE BEGINNING DEMOLITION
OR CONSTRUCTION WITHIN WORK AREA
STICKY MAT
PLASTIC PARTITIONS TO REMAIN WHILE ANY DUST PRODUCING ACTIVITIES OCCUR ON THIS SIDE OF WORK AREA
PLASTIC PARTITIONS TO REMAIN WHILE ANY DUST
PRODUCING ACTIVITIES OCCUR ON THIS SIDE OF
WORK AREA
REMOVABLE ASTRAGAL -RETURN TO POSITION AT END OF
EACH WORK DAYSTICKY MAT
EXISTING CLASSROOM
EXISTING BREAKROOM
EXISTING CONFERENCE
MAINTAIN ACCESS TO EXIT STAIR DURING CONSTRUCTION
EXISTING LIBRARY -NO WORK
EXIST TELECOM
ON DAYS IN WHICH CONSTRUCTION IS NOT
ALLOWED DUE TO TESTING, LEAVE CROSSHATCHED
AREA CLEAN AND CLEAR OF DEBRIS FOR ADA STUDENT
ACCESS
50
' TO
RR
RESTROOMS AVAILABLE FOR CONTRACTOR USE
CONTRACTOR TO INSTALL PLASTIC "ZIP WALL" OVER ELEVATOR ENTRANCE BEFORE BEGINNING CONSTRUCTION
1. CONTRACTOR TO TAKE PHOTOS OF ALL SPACES, HALLWAYS, COURTYARDS TO BE ACCESSED BY CONTRACTOR BEFORE CONSTRUCTION BEGINS. PHOTO LOCATION & SUBMISSION TO PROJECT TO BE COORDINATED WITH OWNERS REPRESENTATIVE. MAINTAIN ALL ACCESSED SPACES IN GOOD CONDITION.
2. MINIMIZE NOISE AND KEEP VOICES LOW WHEN ACCESSING AREA OF WORK; PROJECT IS IN AN OCCUPIED BUILDING
3. 1ST FLOOR RESTROOMS WITHIN MEDICAL SCIENCE ADDITION BUILDING ARE AVAILABLE FOR CONTRACTOR USE. MAINTAIN RESTROOM CLEANLINESS.
4. ALL FURNITURE TO BE RELOCATED BY OWNER. NOTIFY OWNERS REPRESENTATIVE OF ANY FURNITURE THAT NEEDS TO BE MOVED TO FACILITATE CONSTRUCTION
5. THE EXISTING CLASSROOM, CONFERENCE ROOM AND BREAK ROOM WITHIN THE WORK AREA WILL BE AVAILABLE FOR MATERIALS STORAGE. FURNITURE THAT REMAINS IN THE SPACES SHOULD BE COVERED WITH PLASTIC / PROTECTED AND NOT USED BY CONTRACTOR.
CONSTRUCTION LOGISTICS GENERAL NOTES:
LOTTES HEATH SCIENCES LIBRARY
PATIENT CENTERED
CARE LEARNING CENTER
MED SCIENCE ADDITION
NURSING
COOLING TOWER
CROWDER
CLINICAL SUPPORT
AND EDUCATION
MED SCIENCE
PROJECT LOCATION
0"
4'-0
"8'-0
"24
'-0"
16
'-0"
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
1/8
"=1'-0"
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:1
8 P
M G002SOA PROJECT 19054
CODE SHEET
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/16" = 1'-0"G002
02 LEVEL 01 - CODE PLAN
1/16" = 1'-0"G002
03 CONSTRUCTION LOGISTICS / PHASING PLAN - LEVEL 01
1" = 80'-0"G002
01 KEY PLAN
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
UP
UPUP
GENERAL NOTES - DEMOLITION
1. REMOVE WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
2. DASHED LINES INDICATE ITEMSSCHEDULED FOR REMOVAL ORMODIFICATION
3. PROTECT EXISTING SURFACES &COMPONENTS SCHEDULED TOREMAIN
4. REFER TO MEP DRAWINGS FORADDITIONAL DEMOLITIONINFORMATION
5. BEFORE DEMOLITION PHASECOORDINATE WITH OWNERREPRESENTATIVE
3 4 5 6 7 8
A
B
C
D
E
01
01
0101
06
01
06
01
01
02
06
03
05
05
05
05
05
05
05
05
05
05
05 04
05
07
08
09
10
11
12
13
07
07
07
07
07
07
07
07 07
10
07
07
06
06
07
10
05
11
15
16 16
16
22
22
19
16
17 1716
16
24
21
18
2016
17
17
17
17
2525
25
25
26
LIBRARY
17
01
17
17
CONFERENCE
28
28
28
29
07
29
292929
29
29
HSL163
CLASSROOM
HSL144
MECHANICAL
HSL174
BREAK RM
HSL178A
TELECOM
10
30
31 32
33
0"
4'-0
"8'-0
"24
'-0"
16
'-0"
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
1/8
"=1'-0"
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:43:5
8 P
M A101SOA PROJECT 19054
FIRST FLOOR DEMOPLAN
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/8" = 1'-0"A101
02 DEMOLITION - 1ST FLOOR PLAN
KEYNOTES - DEMOLITION PLAN
01 DOOR, FRAMES & HARDWARE - REMOVE &DISPOSE OF
02 BUILT IN CASEWORK - REMOVE & DISPOSE OF
03 SINK - REMOVE & DISPOSE OF AS INDICATED ONPLUMBING PLANS
04 DRINKING FOUNTAIN - REMOVE & DISPOSE OF -REF MEP
05 GYPSUM BOARD & METAL STUD FRAMING -REMOVE & DISPOSE OF
06 DOOR, SIDELIGHT, FRAME & HARDWARE -REMOVE & DISPOSE OF
07 CARPET TILE AND MOISTURE MITIGATION SHEETGOOD: OWNER TO REMOVE BEFORECONSTRUCTION BEGINS ON-SITE. CONTRACTORTO REMOVE ADHESIVE AND CLEAN FLOOR ASNEEDED FOR NEW CARPET INSTALLATION
08 ADJACENT LIBRARY SPACE - EXISTINGFURNITURE TO BE TEMPORARILY RELOCATED BYOWNER BEFORE CONSTRUCTION BEGINS
09 VINYL COMPOSITE TILE - REMOVE & DISPOSE OF
10 CARPET TILE - REMOVE AS NECESSARY FORNEW CONSTRUCTION AND SALVAGE FORREINSTALLATION
11 FIRE ALARM - PROTECT DURING CONSTRUCTION
12 VINYL TILE - PROTECT DURING CONSTRUCTION
13 FLOORING - TO REMAIN
14 NOT USED
15 BASE BID - REMOVE RUBBER BASE; EXISTINGMOSAIC TILE TO REMAIN. ALTERNATE #1 -REMOVE EXISTING RUBBER BASE AND MOSAICTILE
16 JOHNSON CONTROL - REF MEP FOR SCOPE
17 CORNER GUARDS - REMOVE ALL COMPONETS &DISPOSE OF. PATCH FLUSH WITH SURROUNDINGDRY WALL
18 CORNELL RESCUE PANEL - SALVAGE ANDREINSTALL - REF MEP
19 LIBRARY RECEIVING RING BELL - REMOVE &DISPOSE OF
20 FIRE DEPARTMENT VALVE - REFER MEP FORSCOPE
21 SUMP PUMP ALARM - PROTECT DURINGCONSTRUCTION
22 ELECTRIC HEATERS - REMOVE & DISPOSE OF -REF MEP
24 CORNER GUARDS - REMOVE & DISPOSE OFEXISTING SNAP ON COVER, KEEP RETAINER INPLACE FOR NEW CORNER GUARD SNAP ONSECTION TO BE INSTALLED (CG-1)
25 SAW CUT CONCRETE FLOOR FOR NEWPLUMBING - REFER MEP
26 LIGHTED SIGN - REMOVE & RETURN TO OWNER
27 (NOTE NOT USED)
28 SALVAGE EXISTING WALL BASE - TO BEREINSTALLED IN LOCATIONS INDICATED ONFINISH FLOOR PLAN (ERB-1)
29 EXISTING WALL BASE - REMOVE & DISPOSE OF
30 DEMOLISH GYPSUM BOARD AS NEEDED FORNEW WIRING
31 WALL MOUNTED TELEVISION - OWNER TOREMOVE BEFORE CONSTRUCTION IN THIS ROOM
32 WHITE BOARD - REMOVE & SALVAGE FORREINSTALLATION
33 SOUND ABSORBING PANELS - REMOVE &SALVAGE FOR REINSTALLATION
1" = 60'-0"A101
REFERENCE PLAN LEVEL 0101
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
GENERAL NOTES - DEMOLITION
1. REMOVE WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
2. DASHED LINES INDICATE ITEMSSCHEDULED FOR REMOVAL ORMODIFICATION
3. PROTECT EXISTING SURFACES &COMPONENTS SCHEDULED TOREMAIN
4. REFER TO MEP DRAWINGS FORADDITIONAL DEMOLITIONINFORMATION
5. BEFORE DEMOLITION PHASECOORDINATE WITH OWNERREPRESENTATIVE
3 4 5 6 7 8
A
B
C
D
E
01
02
02
0101
01
01
0101 01 02
07
0101
01
02
0303
04
03
03
030303
06
06
08
09090909
16161616
09
10
03
A102
03
A102
SIM03
A102
SIM03
A102
SIM
11
12
13
14
15
1515
0303 03
02 02
17
4
EXISTING CONCRETE FLOOR & BEAM
EXISTING DUCTWORK VERIFY IT IS ADEQUATELY SUPPORTED PRIOR TO SOFFIT DEMOLITION. RESUPPORT AS NECESSARY
EXISTING FRAMING & DRYWALL -REMOVE & DISPOSE OF
EXISTING FIRE SUPPRESSION HEAD & PIPING - REMOVE PER MEP
EXISTING LIGHT FIXTURE/BOX & CONDUCT - REMOVE PER MEP
EXISTING SOFFIT FRAMING & DRY WALL - REMOVE & DISPOSE OF
SUPPLY AIR DIFFUSER - REF MEP
RETURN AIR GRILLE
CAN LIGHT FIXTURE - REF MEP
2 X 2 LIGHT FIXTURE - REF MEP
2' X 2' LAY-IN ACOUSTICAL CEILING PANEL & GRID SYSTEM
LEGEND - REFLECTED CEILING
PENDANT LIGHT FIXTURE - REF MEP
GWB CEILING
2 X 4 LIGHT FIXTURE - REF MEP
CEILING ELEVATION LEVEL ABOVE 100'-0" FFL
0"
4'-0
"8'-0
"24
'-0"
16
'-0"
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
1/8
"=1'-0"
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:0
0 P
M A102SOA PROJECT 19054
FIRST FLOOR DEMOREFLECTED CEILING
PLAN
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/8" = 1'-0"A102
02 DEMOLITION - 1ST FLOOR REFLECTED CEILING PLAN
KEYNOTES - DEMOLITION REFLECTED CEILING PLAN
09 CEILING GRID & LIGHTS - NO WORK
10 OVERHEAD PROJECTOR - OWNER TO REMOVE BEFORECONSTRUCTION IN THIS ROOM
11 POWER POLE - REMOVE & DISPOSE OF (COORDINATE WITHOWNER) & REFER MEP
12 LINEAR COVE LIGHT - REMOVE & DISPOSE OF - REFER MEP
13 FLUORESCCENT LIGHT FIXTURE - REMOVE & DISPOSE OF
14 SOUND ABSORBING CEILING PANELS - REMOVE & SALVAGE FORREINSTALLATION
15 CEILING GRID, ACOUSTICAL PANELS, LIGHT FIXTURES &DIFFUSERS - REMOVE AND SALVAGE FOR REINSTALLATION ASNEEDED FOR WALL AND DUCT MODIFICATIONS - REFER MEP
16 CEIILING TILES - REMOVE AND REINSTALL AS NEEDED TO FIRECAULK PENETRATIONS ABOVE CEILING
17 EXISTING PIPING TO REMAIN - PROTECT - REF MEP
KEYNOTES - DEMOLITION REFLECTED CEILING PLAN
01 CEILING GRID, TILE, LIGHT FIXTURES & SUPPLY / RETURNGRILLES - REMOVE & DISPOSE OF
02 CEILING GRID & TILE TO REMAIN - PROTECT, REMOVE & REPLACETILES AS NEEDED FOR NEW CONSTRUCTION
03 SOFFIT FRAMING, GYPSUM BOARD, MECHANICAL GRILLES &FLUORESCENT LIGHT FIXTRUES - REMOVE & DISPOSE OF. REFMEP FOR SCOPE OF DUCTWORK REMOVAL. WHERE EXISTINGDUCTS REMAIN, PROTECT DUCTS & COVER OPENINGS DURINGCONSTRUCTION TO PREVENT DUST FROM ENTERING.
04 SOFFIT TO REMAIN - PROTECT
05 (NOTE NOT USED)
06 CEILING GRID & ACOUSTICAL PANELS - REMOVE & MODIFY TOEXTENT REQUIRED TO INSTALL NEW WALLS
07 BASE BID - NO WORK. ALTERNATE #2 - LAY-IN CEILING - REMOVE &DISPOSE OF GRID, TILES & LIGHT FIXTURES. SALVAGE DIFFUSERS& GRILLES FOR REINSTALLINATION
08 BASE BID - NO WORK. ALTERNATE #2 - FLUORESCENT COVELIGHTING - REMOVE AND DISPOSE OF - REFER MEP
3/4" = 1'-0"A102
DTL SECT - TYP EXISTING SOFFIT DEMO03
1" = 60'-0"A102
REFERENCE PLAN01
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
UP
UPUP
3 4 5 6 7 8
A
B
C
D
E
A501
A50118
HSL158
ANESTH OFF 3
HSL157
ANESTH OFF 2
HSL156
ANESTH OFF 1
HSL159
ANESTH OFF 4
HSL162
ANESTH OFF 5
HSL160
ANESTH OFF 8
HSL161
ANESTH OFF 6
HSL154
ANESTHCONFERENCE
HSL153
ANESTH OFF 7
HSL151
OPENWORKSTATION
AREA
HSL150
LOBBY
HSL178A
TELECOM
HSL180
CUSTODIAL
HSL178
STORHSL176
LACT
HSL177
RR 1HSL175
RR 2
HSL172
CORR
HSL173
SOM OFFICEHSL171
SOM OFFICE
HSL174
BREAK RM
HSL170
SOM OFFICE
HSL169
SOM OFFICE
HSL168
SOM OFFICE
HSL167
SOM OFFICE
HSL155
CORR
HSL165
CORR
HSL163
CLASSROOM
15
A501
01
A501
19
A201
03
A201
04
02
02
02
02
02
03
02
02
01
10
'-4 7
/8"
10
'-4 7
/8"
10
'-4 7
/8"
HSL152
OPENWORSTATION
AREA
159158
157
156
160
161
162
153
151B
178
180
176
175
173
171
170
169
168
167
177
11'-4" 10'-8 1/8" 7'-8 7/8"
174
07
A20205
04
04
04
04 04
04 04
03 03
10'-10 3/8" 6'-5" 12'-4 7/8" 12'-5 3/8"
03
04
25
'-6
"
03
02
HSL119
OFFICE
HSL118
OFFICE
HSL144
MECHANICAL
03
02
03
03
05
05
HSL100
LIBRARY
HSL100E
CORR
11
'-3 5
/8"
11
'-3 1
/4"
150
151A
14
02
MIN
18"
MIN
18"
MIN
18"
MIN
18"
MIN
18"
MIN
18"
03
03
03
9'-8 3
/4"
9'-8 3
/4"
9'-8 3
/4"
9'-8 3
/4"
9'-8 3
/4"
4'-9 7
/8"
45.00°
06
06
11
1106
06
08
09
06
12
12
A50112
11
A50116
A201
06Sim
13
HSL100E
CORR
10'-10 3/8"
03
03
03
03
02
02
03
03
03
03
14
02
15
14
03
02
E E
165
16
10
17
C
CC
BBB
B
D
DD
C
C
C
Generic - 12"
CCC
18
18
19
20F
19
19
16
21
22
22
22
22
16 16
NEW WORK GENERAL NOTES
1. FIELD VERIFY ALL DIMENSIONS. IFDIMENSIONS VARY SIGNIFICANTLYNOTIFY THE ARCHITECT
2. ALL DIMENSIONS TO FACE OF STEELSTUD OR EXISTING FINISH UNLESSNOTED OHERWISE
3. REFER TO SHEET A702 FORPARTITION TYPES. ALL NEWPARTITIONS ARE TYPE 'A' UNLESSNOTED OTHERWISE
4. LOCATE GYPSUM BOARD CONTROLJOINTS AT DOOR FRAMES WHENPOSSIBLE
5. GRAYED WALLS & DOORS AREEXISTING TO REMAIN - PROTECTDURING CONSTRUCTION
6. EXISTING WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
7. NEW WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
07
A202
CARD READER -BY OWNER
NEW TILE - CENTER ON DOOR & EQUAL DISTANCE NORTH TO SOUTH FROM DOOR JAMB TO EXISTING TILE AS SHOWN
ALT #1: NEW TILE; BASE BID EXISTING MOSAIC TILE TO REMAIN
150 2
TR-2
EQ
EQ
TR-4 - (IF #1 IS REJECTED) - ALIGN FACE OF TRANSITION W/ EXISTING WALLS
5
03
A202
8'-0
"
CARD READER -BY OWNER
EXISTING FIRE ALARM PANEL - PROTECT
151A
NEW HOLLOW METAL FRAME & WOOD DOOR
EXISTING WALL
ALIGN
2
EQ
EQ
EXISTING TILE TO REMAIN -PROTECT
INFILL WALL WHERE DOOR IS REMOVED
DOOR CENTERED ON WALL
TR-2
05
A201
Sim
07
A201
Sim
EXISTING BALUSTRADE -PROTECT
EXISTING BALUSTRADE -PROTECT
1/2" FIRE-TREATED MDF, PAINTED IPS- IPS-1D
ALIGN EDGE OF MDF W/ FACE OF GYP. BD. BELOW
1/2" FIRE-TREATED MDF, PAINTED IPS-1D
SEALANT
3 5/8" CONTINUOUS MTL TRACK
COUNTERSINK FASTENERS AND FILL VOID AND SAND SMOOTH
EXISTING HANDRAIL
1/2" FIRE-TREATED MDF, PAINTED IPS-1D
SEALANT
CONTINUOUS MTL TRACK BEYOND
5/8" TYPE 'X' GYP BD. COPE TO UNDERSIDE OF MDF AND EXISTING FLOOR PLATE
05
A201
Sim
FASTENERS
0"
4'-0
"8'-0
"24
'-0"
16
'-0"
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
1/8
"=1'-0"
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:0
3 P
M A201SOA PROJECT 19054
FIRST FLOOR PLAN
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/8" = 1'-0"A201
02 FIRST FLOOR NEW WORK PLAN
KEYNOTES - NEW WORK PLAN
01 HIGH/LOW DRINKING FOUNTAIN -REFER TO PLUMBING & TYPICALMOUNTING HEIGHTS
02 ALIGN NEW WALL WITH ADJACENTSURFACE - PATCH AS NEEDED TOCREATE SMOOTH TRANSITION
03 EXISTING WALL - SKIM COAT &REFINSIH PER FINISH SCHEDULE
04 ALTERNATE #3 - COUNTER TOP &SUPPORT BRACKETS
05 CARD READER - BY OWNER
06 PATCH AND PAINT AS NEEDED AFTERCORNER GUARD REMOVAL
07 NOT USED
08 MOP SINK - REF MEP
09 (CG-1) NEW SNAP ON COVERINCLUDING TOP AND BOTTOM ENDCAPS - INSTALL ON EXISTINGRETAINER HARDWARE
10 PATCH AND PAINT AS NEEDED AFTERELECTRICAL WORK
11 PARTIALLY RECESSED FIREEXTINGUISHER CABINET
12 FLOOR DRAIN - REFER MEP
13 DASHED LINE INDICATES BALUSTRADEDETAIL ABOVE
14 CONCRETE FLOOR PATCH
15 REFRIGERATOR - BY OWNER
16 EXISTING WALL - INFILL HOLE FROMDUCTWORK / SOFFIT REMOVAL.SMOOTH FLUSH WITH ADJACENTWALL.
17 WALL PATCH & PAINT AS NEEDEDAFTER DRINKING FOUNTAIN REMOVAL
18 EXISTING WALL - EXTEND GYPSUMBOARD TO DECK WHERE NOTPRESENT - FIRE SEAL ALLPENETRATIONS - EXISTING & NEW
19 NEW 1 HR RATED PARTITION
20 EXISTING WALL TO DECK - FIRE SEALALL PENETRATIONS EXISTING & NEW
21 EXTEND FRAMING AND GYPSUMBOARD TO DECK
22 INFILL / PATCH WALL AFTER REMOVALOF TEMPORARY DUCT
1/2" = 1'-0"A201
03 ENLARGED PLAN - LOBBY ENTRANCE
1/2" = 1'-0"A201
04 ENLARGED PLAN - ANESTHESIOLOGY ENTRANCE
1 1/2" = 1'-0"A201
BALUSTRADE @ 2ND FLOOR - PLAN DTL061 1/2" = 1'-0"A201
BALUSTRADE @ 2ND FLOOR - CROSS SECT05
1 1/2" = 1'-0"A201
BALUSTRADE @ 2ND FLOOR - SECT DTL07
1" = 60'-0"A201
REFERENCE PLAN01
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
SUPPLY AIR DIFFUSER - REF MEP
RETURN AIR GRILLE
CAN LIGHT FIXTURE - REF MEP
2 X 2 LIGHT FIXTURE - REF MEP
2' X 2' LAY-IN ACOUSTICAL CEILING PANEL & GRID SYSTEM
LEGEND - REFLECTED CEILING
PENDANT LIGHT FIXTURE - REF MEP
GWB CEILING
2 X 4 LIGHT FIXTURE - REF MEP
CEILING ELEVATION LEVEL ABOVE 100'-0" FFL
3 4 5 6 7 8
A
B
C
D
E
01
02
3'-0"
11
'-1 3
/8"
05
A202
06
A202
05
A202
SIM
05
A202
SIM
07
A202
03
03
A202
SIM
8'-6"
04
8'-6"
8'-6"
8'-6"
8'-6"
8'-6" 8'-6"
8'-6" 8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
05
07
08
06
04
A202
09
09 09 09 09
09
10
10
8'-5"
8'-0" 8'-5"8'-0"
8'-5"
8'-6"
06
A202
SIM
06
A202
SIM
06
A202
SIM
08
A202
12'-6 3/4"
08
A202
SIM
A201
06Sim
8'-5"
HSL151
OPENWORKSTATION
AREA
HSL153
ANESTH OFF 7
HSL155
CORR
HSL161
ANESTH OFF 6
HSL160
ANESTH OFF 8
HSL162
ANESTH OFF 5
HSL159
ANESTH OFF 4
HSL158
ANESTH OFF 3
HSL157
ANESTH OFF 2
HSL156
ANESTH OFF 1
HSL155
CORR
HSL155
CORR
HSL154
ANESTHCONFERENCE
HSL163
CLASSROOM
HSL165
CORR
HSL167
SOM OFFICE
HSL168
SOM OFFICE
HSL169
SOM OFFICE
HSL170
SOM OFFICE
HSL171
SOM OFFICEHSL173
SOM OFFICE
HSL174
BREAK RM
HSL144
MECHANICAL
HSL177
RR 1
HSL175
RR 2
HSL150
LOBBY
HSL178
STOR
HSL178A
TELECOM
HSL180
CUSTODIAL
HSL176
LACT
HSL100E
CORR
HSL100E
CORR
HSL100
LIBRARY
8'-5"
1111
11
1111
11
05 12
ALTERNATE #2
07070707
07 07
07
13 13
0303
13 13
8'-5"
3 5/8" MTL STUD FRAMING 16" O.C.
5/8" TYPE 'X' GYP BD BOTH SIDES
LAY-IN CEILING
SOUND BATT INSULATION
VARIES
IPS-2A
108'-5"108'-6"
EXISTING GRID CEILING - REMOVE & REPLACE AS NEEDED FOR CONSTRUCTION (ALT #2: DEMO & REPLACE)
H.M. DOOR & FRAME
GYPSUM BOARD CEILING PAINT IPS-2A
MTL CEILING FRAMING
GYPSUM BOARD CEILING - PAINT IPS-2A
SOUND BATT INSULATION
108'-6"
108'-0"ACOUSTICAL CEILING
EXISTING CONSTRUCTION
3 5/8" MTL STUD FRAMING
5/8" TYPE 'X' GYP BD
HOLLOW MTL DOOR FRAME
3'-0"
6" 18 GAGE MTL STUD
5/8" TYPE 'X' GYP BD.
3 5/8" MTL STUD TRACK
IPS-2A
IPS-2A
EXISTING FLOOR AND BEAM
5/8" TYPE 'X' GYP BD.
MTL STUD @ 16" O.C
112'-6 3/4"
108'-5"
EXISTING GYP BD CEILING: PAINT IPS-2A
GYP BD SOFFIT
IPS-2A
+/- 3 5/8"FIELD VERIFY AND ADJUST FRAMING SIZE AS HEADED TO CENTER EXISTING WINDOW - REF 19/A501
GENERAL NOTES - CEILING
1. FOR SPECIFICATION OF LIGHTFIXTURES AND MECHANICAL SYSTEMCOMPONETS - REF TO MEP
2. CEILING LEGEND IS SYMBOLIC TOACTUAL FIXTURE - REF TO MEPFIXTURE SCHEDULES
3. FOR LOCATIONS OF LIGHT FIXTURES- REF MEP
EXISTING BULKHEAD
EXISTING SUSPENDED CEILING SYSTEM
ACOUSTICAL LAY-IN CEILING
GRID ANGLE
6"
±
PAINT IPS-2B108'-0"
1"
LAY-IN CEILING
3 5/8" MTL STUD FRAME
5/8" TYPE 'X' GYP BD.
CEILING GRID ANGLE
IPS-2A
108'-6"
108'-5"
0"
4'-0
"8'-0
"24
'-0"
16
'-0"
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
1/8
"=1'-0"
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:0
6 P
M A202SOA PROJECT 19054
FIRST FLOORREFLECTED CEILING
PLAN
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
KEYNOTES - NEW WORK REFLECTED...
01 EXISTING REMNANT OF CONCRETE STAIR
02 METAL FRAMING & GYPSUM BOARD SOFFIT
03 EXISTING SOFFIT
04 ALTERNATE #2 - REPLACE CEILING TILE & CEILING GRID
05 EXISTING GYPSUM BOARD CEILING - PATCH & PAINT(IPS-2A)
06 EXISTING & MECHANICAL DIFFUSERS - PROTECT &SALVAGE & REINSTALL AS NEEDED TO INSTALL NEWCEILING & GRID FOR ALT #2
07 REINSTALL SLAVAGED CEILING TILE THIS AREA
08 WALL MOUNTED LIGHT FIXTURE - REF MEP
09 EXISTING CEILING GRID & LIGHTS - NO WORK
10 CEILING GRID & TILES TO REMAIN - PROTECT, REMOVE &REPLACE TILES AS NEEDED FOR NEW CONSTRUCTION
11 ALIGN NEW SOFFIT WITH ADJACENT SURFACES -PATCHAS NEEDED TO CERATE SMOOTH TRANSITION
12 PAINT ALL EXPOSED DUCTS, PIPES & GYPSUM BD.SOFFIT & CEILING. CLEAN EXISTING SURFACES BEFOREPAINTING
13 CAP OFF EXISTING SOFFIT TO REMAIN WITH METALFRAMING AND GYPSUM BOARD. PAINT IPS-2A
1/8" = 1'-0"A202
02 FIRST FLOOR NEW WORK REFLECTED CEILING PLAN
1 1/2" = 1'-0"A202
DTL SECT - TYP. SOFFIT061 1/2" = 1'-0"A202
DTL SECT - SOFFIT AT LOBBY ENTRANCE07
1 1/2" = 1'-0"A202
DTL - ANESTHESIOLOGY ENTRANCE SOFFIT03
1 1/2" = 1'-0"A202
DTL SECT - SOFFIT @ CONF. CORRIDOR08
1" = 60'-0"A202
REFERENCE PLAN LEVEL 0101
1 1/2" = 1'-0"A202
DTL SECT - EXISTING BULKHEAD04
1 1/2" = 1'-0"A202
DTL SECT - TYP. BULKHEAD05
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
UP
1 2 3 4 5 6 7 8
A
B
C
D
E
201
HSL 201
PLASTIC PARTITION TO REMAIN DURING ANY DUST -PRODUCING ACTIVITES
OWNER TO MOVE ALL FURNITURE AND EQUIPMENT TO THIS SIDE OF ROOM, AND PROTECT WITH PLASTIC, BEFORE CONSTRUCTION BEGINS
CONTRACTOR TO COORDINATE ACCESS TO THIS WORK AREA WITH OWNER'S CONSTRUCTION REPRESENTATIVE
LIBRARY - NO WORK
THIS FLOOR OF THE LIBRARY WILL BE OCCUPIED THROUGHOUT CONSTRUCTION - KEEP VOICES & NOISE TO A MINIMUM
A203
06
7 8
D
CUT CONCRETE SLAB FOR NEW DUCT - REF MEP - PROTECT ADJACNET BEAMS
201
HSL 201
EXISTING WALL HEATER - REMOVE & DISPOSE OF - REF MEP
EXISTING CASEWORK, FLOORING & FINISHES -PROTECT
EXISTING FABRIC & FRP WALL PANELS - REMOVE AND DISPOSE AS NECESSARY FOR NEW CONSTRUCTION
EXISTING FABRIC & FRP WALL PANELS TO REMAIN -PROTECT
EXISTING WALL HEATERS - PROTECT
7 8
D
201
HSL 201
DEMOLISH EXIST MASONRY WALL AS REQUIRED FOR DUCT/VENT. +/- 6' ABOVE FLOOR LEVEL - REF MEP
EXISTING CEILING & SOFFIT TO REMAIN - PROTECT
7'-7"
7'-11 1/2"
7 8
D
201
HSL 201
PATCH & PAINT EXIST SOFFIT (IPS-2A)7'-7"
7'-11 1/2"
8'-7"
NEW WORK GENERAL NOTES
1. FIELD VERIFY ALL DIMENSIONS. IFDIMENSIONS VARY SIGNIFICANTLYNOTIFY THE ARCHITECT
2. ALL DIMENSIONS TO FACE OF STEELSTUD OR EXISTING FINISH UNLESSNOTED OHERWISE
3. REFER TO SHEET A702 FORPARTITION TYPES. ALL NEWPARTITIONS ARE TYPE 'A' UNLESSNOTED OTHERWISE
4. LOCATE GYPSUM BOARD CONTROLJOINTS AT DOOR FRAMES WHENPOSSIBLE
5. GRAYED WALLS & DOORS AREEXISTING TO REMAIN - PROTECTDURING CONSTRUCTION
6. EXISTING WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
7. NEW WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
GENERAL NOTES - DEMOLITION
1. REMOVE WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
2. DASHED LINES INDICATE ITEMSSCHEDULED FOR REMOVAL ORMODIFICATION
3. PROTECT EXISTING SURFACES &COMPONENTS SCHEDULED TOREMAIN
4. REFER TO MEP DRAWINGS FORADDITIONAL DEMOLITIONINFORMATION
5. BEFORE DEMOLITION PHASECOORDINATE WITH OWNERREPRESENTATIVE
7 8
D
A203
03
04
F
F
PARTITIONS TO TERMINATE AT UNDERSIDE OF EXIST SOFFIT
3' x 3' ACCESS PANEL - PAINT TO MATCH WALL - REF MEP
FIRE SEAL ANNULAR SPACE AROUND DUCT
201
HSL 201
+/-
4'-3
"
+/- 4'-3"
IPS-1E IPS-1EEXISTING FABRIC PANELS TO REMAIN (PROTECT)
EXISTING FRPPANELS AND WALL BASE TO REMAIN (PROTECT)RB-3
HORIZ. SURFACE OF SOFFIT PAINT (IPS-2A)NO WORK ON VERTICAL SURFACE OF SOFFIT
EXISTING WALL HEATERS - PROTECT
IPS-1E
IPS-1E
RB-3
ACCESS PANEL - REF MEP
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:0
8 P
M A203SOA PROJECT 19054
SECOND FLOOR DEMO+ NEW WORK PLANS
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/16" = 1'-0"A203
CONSTRUCTION LOGISTICS / PHASING PLAN - LEVEL 0202
1/4" = 1'-0"A203
LEVEL 02 - DEMO PLAN05
1/4" = 1'-0"A203
LEVEL 02 - DEMOLTION REFLECTED CEILING PLAN071/4" = 1'-0"A203
LEVEL 02 - REFLECTED CEILING PLAN08
1" = 60'-0"A203
REF PLAN - LEVEL 0201
1/4" = 1'-0"A203
LEVEL 02 - FLOOR PLAN06
1/4" = 1'-0"A203
HSL 201 - EAST ELEVATION03
1/4" = 1'-0"A203
HSL 201 - SOUTH ELEVATION04
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
NEW GYPSUM BOARD & MTL FRAMED SOFFIT - ALIGN UNDERSIDE W/ BOTTOM OF EXISTING SOFFIT
EXISTING FIRE ALARM PANEL -PROTECT
03
A202
7'-2
" 151A
RB-2
CORNER GUARDS
CORRIDOR3'-0
"
CARD READER BY OWNER
MIRROR (24X36) W/ SHELF
SD
GRAB BARS
TPD
WT-1
TR-3
WT-2
EHD177
WT-1
TR-3
WT-2
CH
3'-6
"1
'-6
"
GRAB BARS
TPD
WT-1
TR-3
WT-2
ADA BENCH
WT-1
TR-3
WT-2
HIGH/LOW DRINKING FOUNTAIN - REFER TO PLUMBING & TYPICAL MOUNTING HEIGHTS
06
A202
SS-2
178
BASE AS SCHEDULED
MOUNT PANELS TO PARTITION, INCLUDE BACKING REQUIRED. APPLY CLEAR SEALANT AT MATERIAL TRANSITIONS
SCRIBE PANEL TOP AND BOTTOM INCLUDE SEALANT AT FLOOR PLANE
90" MAX
C.L.
7 8
D
A50105
02
03
04
A501
06
07
08
09
6'-5 1
/8"
10
1/4
"7
'-9 1
/2"
177 175
176
178
HSL177
RR 1
HSL175
RR 2
HSL178
STOR
HSL176
LACT
A50113
REFRIGERATOR -BY OWNER
A50112
11
HSL178A
TELECOM
HSL180
CUSTODIAL
180
1'-9 1/8" 3 5/8" 10'-3 7/8" 46" MIN 8'-7 5/8"
EQ
EQ
90"
MA
X
2'-1"
EE
NOTE: EXISTING SERVERS/RACKS TO REMAIN - PROTECT -COORDINATE ALL WORK IN THIS ROOM W/ OWNER'S REP & IT
FINISH16-18" TO WALL
5'-0"
FINISH16-18" TO WALL
6'-0"
ADA BENCH - BY OWNER
2' X 2' ACCESS PANEL - PAINT TO MATCH WALL - REF MEP
2' x 2' ACCESS PANEL - PAINT TO MATCH WALL - REF MEP
GRAB BARS
TPD
WT-1
TR-3
WT-2
WT-1
TR-3
WT-2
MIRROR (24X36) W/SHELF
GRAB BARS
TPD
SD
WT-1
TR-3
WT-2
WT-1
SD
175
WT-1
TR-3
WT-2
EHD
CH
3'-6
"1
'-6
"
EXISTING DOOR - EXISTING FRAME TO BE PAINTED IPS-5A
EXISTING INTERIOR H.M. WINDOWS - FRAME TO BE PAINTED IPS-5A ON BOTH SIDES
A202
08
PATCH AND PAINT WHERE DISPLAY PANEL REMOVED (IPS-1A)
EQ EQ
ADJUST SOFFIT FRAMING SO EXISTING WINDOW IS CENTERED IN SPACE
8'-0"
07
A202
180150
CREATE SMOOTH TRANSITION BETWEEN INFILL WALLS AND EXISTING WALL; PATCH AND PAINT - TYPICAL
RB-1
EXISTING DOOR TO REMAIN
PAINT EXIST DOOR FRAME IPS-5A
CARD READER -BY OWNER
CORNER GUARD
SS-1
PL-1 (APRON)
2'-10
" REFRIGERATOR -BY OWNER
MIRROR WITH SHELF
OUTLET - REF MEP
02
A702
Sim
PAPER TOWEL DISPENSER
RB-1
ACCESSORIES ARE PROVIDED AND INSTALLED AS NOTED BELOW:
TPO: TOILET PAPER HOLDER - OWNER PROVIDED, CONTRACTOR INSTALLEDPTD: PAPER TOWEL DISPENSER - OWNER PROVIDED, CONTRACTOR INSTALLEDEHD:ELECTRIC HAND DRYER - OWNER PROVIDED, CONTRACTOR INSTALLEDADA BENCH - OWNER PROVIDED, OWNER INSTALLEDSD: SOAP DISPENSER - OWNER PROVIDED, CONTRACTOR INSTALLEDMIRROR - CONTRACTOR PROVIDED & INSTALLEDCH: COAT HOOKS - CONTRACTOR PROVIDED & INSTALLEDMOP AND BROOM HOLDER - CONTRACTOR PROVIDED & INSTALLEDGB: GRAB BARS - CONTRACTOR PROVIDED & INSTALLED
ACCESSORY NOTES / LEGEND:
A202
03
GYPSUM BOARD & MTL FRAMED SOFFIT - ALIGN W/ UNDERSIDE OF ADJACENT SOFFIT
PAINT DOOR FRAME, LITE FRAME, & SIDELIGHT FRAME (IPS-5A)
RB-2
CG-1
CG-1
4'-0"
4'-0
"
FRP PANELS
MOP SINK - REF MEP
RB-1
MOP & BROOM HOLDER
4'-0
"
4'-0"
RB-1
MOP SIINK - REF MEP
FRP PANELS
PL-203
A702
Sim
RB-1
PAINT ASSCHEDULED
ALT #3: COUNTERTOPS & SUPPORT BRACKETS 4'-0" O.C.
2'-6
"
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:1
2 P
M A501SOA PROJECT 19054
INTERIOR ELEVATIONS
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/4" = 1'-0"A501
CORRIDOR HSL100E - EAST18
1/4" = 1'-0"A501
RR 1 - SOUTH041/4" = 1'-0"A501
RR 1 - EAST031/4" = 1'-0"A501
RR 1 - WEST051/4" = 1'-0"A501
RR 1 - NORTH02
1/4" = 1'-0"A501
LOBBY - WATER FOUNTAIN15
1/4" = 1'-0"A501
ENLARGED PLAN - ANESTH RESTROOMS01
1/4" = 1'-0"A501
RR 2 - EAST071/4" = 1'-0"A501
RR 2 - NORTH061/4" = 1'-0"A501
RR 2 - SOUTH081/4" = 1'-0"A501
RR 2 - WEST09
1/4" = 1'-0"A501
CORR HSL155 - SOUTH WALL19
1/4" = 1'-0"A501
CORRIDOR - NORTH WALL10
1/4" = 1'-0"A501
LACT - EAST131/4" = 1'-0"A501
CORRIDOR HSL100E - SOUTH141/4" = 1'-0"A501
CUSTODIAL WEST121/4" = 1'-0"A501
CUSTODIAL - SOUTH11
1/4" = 1'-0"A501
OFFICE - TYP. BUILT IN DESK16
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
1. CARPET TILE PATTERNS ARE INTENDED TO SHOW EXTENTS AND DIRECTION OF MATERIAL AND ARE NOT REPRESENTATIVE OF INSTALLATION PATTERN. REFERENCE APPENDIX A 'INTERIOR FINISH LEGEND' FOR INSTALLATION PATTERN SPECIFICATION.
2. REFERENCE FLOOR FINISH PLAN FOR EXTENTS OF ACCENT PAINT IPS-1B
FINISH SCHEDULE NOTES:
RR 2
HSL175
FLOOR:T-1
RR 1
HSL177
FLOOR:T-1
STOR
HSL178
FLOOR:CT-1
LACT
HSL176
FLOOR:CT-1
CUSTODIAL
HSL180FLOOR:EXPOSED EXISTING
CONCRETE
TELECOM
HSL178A
FLOOR:EXISTING
ANESTHCONFERENCE
HSL154
FLOOR:CT-1
ANESTHOFF 1
HSL156
FLOOR:CT-1
ANESTHOFF 2
HSL157
FLOOR:CT-1
ANESTHOFF 3
HSL158
FLOOR:CT-1
CLASSROOM
HSL163FLOOR:EXISTING, PATCH
EXISTING
BREAKRM
HSL174
FLOOR:EXISTING
ANESTHOFF 6
HSL161
FLOOR:CT-1
ANESTHOFF 7
HSL153
FLOOR:CT-1
ANESTHOFF 4
HSL159
FLOOR:CT-1
ANESTHOFF 5
HSL162
FLOOR:CT-1
SOMOFFICE
HSL173
FLOOR:CT-1
SOMOFFICE
HSL171
FLOOR:CT-1
SOMOFFICE
HSL170
FLOOR:CT-1
SOMOFFICE
HSL169
FLOOR:CT-1
SOMOFFICE
HSL168
FLOOR:CT-1
SOMOFFICE
HSL167
FLOOR:CT-1
ANESTHOFF 8
HSL160
FLOOR:CT-1
LOBBY
HSL150
FLOOR:CT-1
CORR
HSL172
FLOOR:CT-1
CORR
HSL155
FLOOR:CT-1
OPENWORKSTATION
AREA
HSL151
FLOOR:CT-1
TR-2
TR-2
CORR
HSL100E
FLOOR:ALT #1: T-2
IPS-5A
IPS-5A
IPS-5A IPS-5A
IPS-5AIPS-5A
IPS-5A
IPS-5A
ENTRY
HSL100D.1
FLOOR:T-2
IPS
-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS
-1B
IPS-1B
TR-1
TR-2
MECHANICAL
HSL144
FLOOR:EXISTING
IPS
-1C
& R
B-2
NORTH, SOUTH & EAST WALLS : IPS-1C & RB-2
OFFICE
HSL119
FLOOR:CT-1
OFFICE
HSL118
FLOOR:CT-1
LIBRARY
HSL100FLOOR:EXISTING, PATCH
EXISTING
IPS
-1D
& R
B-2
IPS-1D & ERB-1
IPS-1D & RB-2
CORR
HSL165
FLOOR:CT-1
OPENWORSTATION
AREA
HSL152
FLOOR:CT-1
CORR
HSL100E
FLOOR:EXISTING
IPS
-1D
& R
B-2
IPS-5A
IPS-5A
IPS-1C& RB-2
IPS
-1A
&
ER
B-1
IPS-1A & ERB-1
IPS-1A & ERB-1
IPS-1B
ERB-1
RB-2
RB-2 ALL SIDES OF COLUMNS
RB-2
RB-2
IPS-1D & EXISTING BASE TO REMAIN
IPS-1C & RB-2
TR-2
IPS-5A
IPS-5A
NOTE: EXISTING WALL HEIGHT VARIES - ASUME AVERAGE HEIGHT OF 9'-0"
REINSTALL EXISTING CARPET
REINSTALL EXISTING CARPET
IPS
-1B
TR-4 (IF ALT #1 IS REJECTED)
TR-2
REINSTALL EXISTING CARPET
REINSTALL EXISTING CARPET
ALTERNATE #1
REFERENCE APPENDIX A 'INTERIOR FINISH LEGEND' IN SPECIFICATIONS FOR PRODUCT DETAILS
FLOORING:CT: CARPET TILE
T: PORCELAIN TILE
RB: RESILIENT WALL BASE
WALL FINISHES:IPS-1: PAINT ON GYPSUM BOARD
WT: PORCELAIN WALL TILE
ACT: ACOUSTICAL CEILING TILE 2'X2'
IPS-2: CEILING PAINT ON GYP BD
IPS-5: PAINT ON HOLLOW METAL AND WOOD
GENERAL INTERIOR FINISH LEGEND:
G1. FOR ALL INTERIOR FINISH INFORMATION REFERENCE THE APPENDIX A "INTERIOR FINISH LEGEND" IN SPECIFICATIONS
G2. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED IPS-5A
G-3. TRANSITION ALL WALL AND/OR COLOR CHANGES AT INSIDE CORNER, UNLESS NOTED OTHERWISE. CONSULT ARCHITECT FOR CLARIFICATION IF NECESSARY.
G-4. CONTINUE WALL FINISH AS SCHEDULED BEHIND ALL CASEWORK/MILLWORK.
G-5. CONTINUE WALL BASE AS SCHEDULED AT ALL WALLS, FURRED OUT COLUMNS AND COLUMN COVERS AND AT ALL CASEWORK TOE KICKS, SIDE PANELS AND UNDER OPEN COUNTER.
G-6. PROVIDE METAL SUPPORT BRACKETS SPACED PER MANF. RECOMMENDATIONS. REFERENCE SPECIFICATION 064116.
G-7. REFER TO A702 FOR CASEWORK SECTIONS AND TYPICAL MOUNTING HEIGHTS.
G8. PAINT HORIZONTAL FACE OF SOFFITS IPS-2A IN RENOVATION AREAS AND IPS-2B IN EXISTING LIBRARY AREA, PAINT VERTICAL FACE OF SOFFIT SAME AS ADJACENT WALL COLOR UNLESS NOTED OTHERWISE.
G9. REFERENCE FINISH FLOOR PLAN (A701) FOR DIRECTION OF FLOORING MATERIAL, REFERENCE APPENDIX A 'INTERIOR FINISH LEGEND' FOR INSTALLATION PATTERN.
G10. FLOOR FINISH TRANSITIONS TO OCCUR AT DOOR FRAME. TRANSITION TO BE CONCEALED WHEN DOOR IS CLOSED. REFER TO 01/A102.
G11. REFERENCE REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
GENERAL FINISH NOTES:
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:1
4 P
M A701SOA PROJECT 19054
ROOM FINISHSCHEDULES & FINISH
PLAN
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/8" = 1'-0"A701
FINISH FLOOR PLAN01
ROOM FINISH SCHEDULE
ROOM NO ROOM NAME FLOOR BASE
WALLS CEILING
NOTESNORTH SOUTH EAST WEST MATL
201 HSL 201 EXISTING TO REMAIN EXISTING,RB-3
EXISTING EXISTING,IPS-1E
IPS-1E EXISTING EXISTING
HSL100 LIBRARY EXISTING, PATCHEXISTING
RB-2 EXISTING IPS-1C IPS-1C IPS-1C EXISTING
HSL100D.1 ENTRY T-2 RB-2 IPS-1D IPS-1D IPS-1D IPS-1D BASE BID:EXISTING, ACT-1(ALT #1)
1
HSL100E CORR EXISTING EXISTING,RB-2
EXISTING EXISTING IPS-1C EXISTING EXISTING
HSL100E CORR ALT #1: T-2 RB-2 IPS-1C IPS-1C IPS-1C IPS-1C BASE BID:EXISTING, ACT-1(ALT #1)
HSL118 OFFICE CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1B EXISTING
HSL119 OFFICE CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1A EXISTING
HSL144 MECHANICAL EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING
HSL150 LOBBY CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1A ACT-1 1
HSL151 OPENWORKSTATIONAREA
CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1A ACT-1 1
HSL152 OPENWORSTATION AREA
CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1A ACT-1 1
HSL153 ANESTH OFF 7 CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL154 ANESTHCONFERENCE
CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1A IPS-2A 1
HSL155 CORR CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1A ACT-1 1
HSL156 ANESTH OFF 1 CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1B ACT-1 1, 2
HSL157 ANESTH OFF 2 CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1B ACT-1 1, 2
HSL158 ANESTH OFF 3 CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1B ACT-1 1, 2
HSL159 ANESTH OFF 4 CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL160 ANESTH OFF 8 CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL161 ANESTH OFF 6 CT-1 RB-1 IPS-1B IPS-1A IPS-1A IPS-1A ACT-1 1, 2
HSL162 ANESTH OFF 5 CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1B ACT-1 1, 2
HSL163 CLASSROOM EXISTING, PATCHEXISTING
EXISTING EXISTING EXISTING,IPS-1A
EXISTING EXISTING,IPS-1A
EXISTING
HSL165 CORR CT-1 RB-1 IPS-1A IPS-1A IPS-1A IPS-1A ACT-1 1
HSL167 SOM OFFICE CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL168 SOM OFFICE CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL169 SOM OFFICE CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL170 SOM OFFICE CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL171 SOM OFFICE CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL173 SOM OFFICE CT-1 RB-1 IPS-1B IPS-1A IPS-1A IPS-1A ACT-1 1, 2
HSL174 BREAK RM EXISTING EXISTING,ERB-1SOUTH
EXISTING EXISTING,IPS-1A
EXISTING EXISTING EXISTING
HSL175 RR 2 T-1 WT-1, TR-3 WT-1, WT-2(FULL HEIGHT)
WT-1, WT-2(FULL HEIGHT)
WT-1, WT-2(FULLHEIGHT)
WT-1, WT-2(FULL HEIGHT)
ACT-1
HSL176 LACT CT-1 RB-1 IPS-1A IPS-1A, IPS-1B IPS-1A IPS-1A ACT-1 1
HSL177 RR 1 T-1 WT-1, TR-3 WT-1, WT-2(FULL HEIGHT)
WT-1, WT-2(FULL HEIGHT)
WT-1, WT-2(FULLHEIGHT)
WT-1, WT-2(FULL HEIGHT)
ACT-1
HSL178 STOR CT-1 RB-1 IPS-1A IPS-1A IPS-1B IPS-1A ACT-1 1, 2
HSL178A TELECOM EXISTING EXISTING,ERB-1(NORTH)
IPS-1A IPS-1A IPS-1A IPS-1A ACT-1
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
A1
SOLID CORE WOOD DOOR
RE
FE
R T
O S
CH
ED
ULE
REF. TO SCHED.
B1
SOLID CORE WOOD DOOR
REF. TO SCHED.
RE
FE
R T
O S
CH
DU
LE
1/4" CLEAR TEMPERED GLASS
1
HOLLOW METAL FRAME
2"
REF. TO SCHED.
2"
RE
FE
R T
O S
CH
ED
ULE
2"
2
HOLLOW METAL FRAME
DOOR - REFER TO DOOR SCHEDULE
3 5/8" MTL STUD
HOLLOW METAL FRAME IPS-5A U.N.O. ON FINISH PLAN
5/8" TYPE "X" GYP BD
CONT SEALANT @ EA SIDE
FLOOR FINISH TRANSITION TO OCCUR UNDER DOOR
2" 2'-2" 2" 3'-0" 2" 2'-2" 2"
7'-0
"2
"
8'-0"
7'-2
"
1/4" CLEAR TEMPERED GLASS
TO
OU
TLE
T
1'-8"
MIN
.
PAPER TOWEL
DISPENSER (P.T.D.)
6'-0
"
MOP & BROOM HOLDER (M.B.H.)
MIRROR
TYPICAL LAVATORY
TYPICAL WALL HUNG TOILET
TOILET PAPER DISPENSER (T.P.D.)
WATER COOLER & DRINKING FOUNTAIN
FOR DISABLED
FIRE EXTINGUISHER
CABINET (F.E.C.)
3'-6" 1'-0" 1'-0" 2'-0" MIN.
3'-0" MIN.3'-4"
MIN
.
1 1
/2".
2'-11
" T
O T
OP
1'-6"
MIN
.3
'-4
"
1'-0
"4
'-10
"
5'-10
"
1'-6
"3
'-6
"
5'-0
"
6" X 18GA SHEET METAL BACKING; PLACE TO ALIGN W/ MOUNTING ASSEMBLY
TYPICAL WALL HUNG TOILET
TYPICAL URINAL SCREEN
TYPICAL TOILET
PARTITION
4'-0
" T
O T
OW
EL
DIS
PE
NS
ER
2'-10
"
3'-0
"
SOAP DISPENSER
(S.D.)
TO
RE
FL
EC
TIV
E S
UR
FA
CE
3'-4
"
PROTECTIVE INSULATION PLUMBING
TO
LO
WE
R S
PO
UT
2'-11
"
SANITARY NAPKIN
DISPENSER
4'-0
"
PA
RT
S
48"
MA
X T
O O
PE
RA
BLE
3'-4
"
ELECTRIC HAND
DRYER
1'-6
"
1'-6
"
SS COUNTERTOP W/ INTEGRAL BOWL SINK ON 3/4" EXT. PLYWOOD
MA
X
9"
1'-6
"5
1/2
"
1 1
/2"
4"
SINK - REF PLUMBING
P-LAM END PANELS
20 GA. X 6" SHT. MTL. BACKING IN WALL FOR CS ATTACHMENT
PL REMOVABLE PANEL
BASE AS SCHED
MAX
6"
MIN
8"
2'-10
"
2'-1"
18"X18" SUPPORT BRACKET
ALT #3: PLASTIC LAMINATE COUNTERTOP ON 3/4" EXT. PLYWOOD W/ 4" BACKSPLASH
ALT #3: SUPPORT BRACKET
ALT #3: 20 GA. X 6" SHT. MTL. BACKING IN WALL FOR CS ATTACHMENT
BASE
2'-6
"
2'-0"
1 1
/2"
FLOOR LINE
STRUCTURAL DECK
CEILING LINE
3 5/8" 22 GAUGE METAL STUDS @ 16" O.C.
A E
5/8" TILE BACKER
3 5/8" 22 GAUGE METAL STUDS @ 16" O.C.
B C D
1'-0"
FIRE SEALANT
FIRE SEAL ALL PENETRATIONS -EXISTING & NEW
FIRE SEALANT
FIRE SEALANT
FIRE SEALANT
5/8" TYPE 'X' GYPSUM BOARD
FIRE SEAL ALL PENETRATIONS
ACOUSTICAL SOUND BATT INSULATION
3 5/8" 22 GAUGE METAL STUDS @ 16" O.C.
FIRE SEALANT
FIRE SEALANT
FIRE SEAL ALL PENETRATIONS EXISTING & NEW
HATCH INDICATES EXISTING WALL CONSTRUCTION
5/8" TYPE 'X' GYPSUM BD - EXTEND FROM TOP OF EXISTING GYPSUM BD TO DECK
ACOUSTICAL SOUND BATT INSULATION
F
3 5/8" 22 GAUGE METAL STUDS
5/8" TYPE 'X' GYPSUM BOARD ON ONE SIDE
CEILING LINE
STRUCTURAL DECK
1 HR RATEDUL 419
1 HR RATEDUL 419
1 HR RATEDUL 419
HATCH INDICATES EXISTING WALL CONSTRUCTION
5/8" TYPE 'X' GYPSUM BOARD
If you must print this drawing, please recycle
www.soa-inc.com
Missouri Certificate of
Authority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103
Columbia, MO 65202
573.443.1407
3/1
3/2
02
0 3
:44:1
5 P
M A702SOA PROJECT 19054
DOOR FINISHSCHEDULES
ISSUE FOR BID
MARCH 19, 2020
Jennifer Marie Hedrick - ArchitectLicense No. A-7827
Lo
ttes
1s
t F
loo
rR
en
ov
ati
on
Ph
ase
On
e9 H
osp
ital
Dr
Bu
ild
ing
#37144
Co
lum
bia
, M
O
1/4" = 1'-0"
DOOR TYPES1/4" = 1'-0"
FRAME TYPES
1 1/2" = 1'-0"A702
INT. STUD - DOOR HEAD/JAMB DETAIL, TYP01
DOOR AND FRAME SCHEDULE
DOOR FRAME FIRERATINGLABEL
HARDWARE SET NO NOTES
DOORNO
SIZE
MATL ELEV MATL ELEV
DETAIL
W H THK HEAD JAMBLEVEL 01
180 3'-6" 7'-0" 1 3/4" SCWD A1 HM 1 6
150 3'-0" 7'-0" 1 3/4" SCWD B1 HM 2 1
151A 3'-0" 7'-0" 1 3/4" SCWD B1 HM 2 1
151B 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 2
174 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 4
178 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
153 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
156 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
157 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
158 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
159 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
160 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
161 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
162 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
165 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 45 MIN 3
167 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
168 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
169 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
170 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
171 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
173 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 3
175 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 5
176 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 5
177 3'-0" 7'-0" 1 3/4" SCWD A1 HM 1 5
1/2" = 1'-0"
TYP. MOUNTING HEIGHTS
1/2" = 1'-0"A702
DTL - TYP. ADA APRON02
1/2" = 1'-0"A702
DTL - TYP. BUILT IN DESK03
1 1/2" = 1'-0"
PARTITION TYPES
FI
ISSOUR
OETA
ST
M
RE
GIS
TERED AR
CH
ITE
CT
03/19/2020
JENNIFER
MARIEHEDRICKNUMBER
A-7827
REVISION DATE
-
UP
UPUP
3 4 5 6 7 8
A
B
C
D
E
LIBRARY
CONFERENCE
HSL163CLASSROOM
HSL144MECHANICAL
HSL174BREAK RM
HSL178ATELECOM
T
T
T
urgent
T
T
If you must print this drawing,please recycle
www.soa-inc.com
Missouri Certificate ofAuthority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103Columbia, MO 65202573.443.1407
MEP ENGINEER:
912 Old 63 SouthColumbia, MO 65201
573-875-4365
CE PROJECT COL20003
ISSUE FOR BID
03-19-2020
LOTT
ES 1
ST F
LOO
RR
ENO
VATI
ON
PH
ASE
ON
E1
HO
SPIT
AL
DR
IVE
CO
LUM
BIA
, BO
ON
E C
OU
NTY
, MO
REVISION DATE
Shane Floyd, P.E.PE-2019017814MO Certificate of Authority #2006012388
MARCH 19TH, 2020
0"4'-
0"8'-
0"24
'-0"
16'-0
"1/8
"=1'-0
"
DP101
FIRST FLR. PLUMBINGDEMOLITION PLAN
PLUMBING PLENUM SPACE NOTESMATERIALS EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTME 84.
NO WORKTHIS AREA
GENERAL NOTES1. REFER TO P501 AND P601 FOR REMAINING POWER NOTES, LEGENDS, DETAILS & SCHEDULES2. ALL PLUMBING FIXTURES AND PIPING LABELED 'EX' OR 'EXISTING' SHALL BE EXISTING TO REMAIN UNLESS NOTED
OTHERWISE.3. ALL EXISTING PLUMBING FIXTURES AND PIPING SHOWN ARE AN APPROXIMATION BASED ON EXISTING PLANS,
SPECIFICATIONS, AND FIELD SURVEYS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS OF PLUMBING FIXTURES ANDPIPING PRIOR TO START OF CONSTRUCTION. PROVIDE REPORT TO OWNERS REPRESENTATIVE OF ALL DEVIATIONS WHICHWILL AFFECT RENOVATION / NEW INSTALLATIONS AS SHOWN ON THE PLANS.
PLENUM SPACE NOTETHIS PROJECT INCLUDES A PLENUM SPACE
CONTRACTORS SHALL USE NON COMBUSTIBLE OR PLENUM RATED MATERIALS ABOVE CEILING:- EMT CONDUIT, CAST IRON SANITARY & VENT PIPING
SEE EACH SHEET FOR SPECIFIC PLENUM NOTES
FIRST FLR. PLUMBING DEMOLITION PLANSCALE : 1/8" = 1'-0"
KEY PLANSCALE: 1" = 60'-0
EXISTING2" SAN
HOT WATER
HOT WATER RECIRCULATION
PLUMBING SYMBOL LEGENDSANITARY SEWER
VENT
COLD WATER
AIR
GAS
WATER METER
GAS METER
PIPE LINE TURNED UP / PIPE LINE TURNED DOWN
PUMP
M
G
VALVE
TIE INTO EXISTING
FILTERED WATER
EXISTING FIRE DEPARTMENT VALVE. FIRE SPRINKLERCONTRACTOR SHALL DEMO VALVE AND PIPE TO
ABOVE CEILING AND CAP AT SPRINKLER MAIN.1
2
EX. 3 4" CW UP
EX. 21 2" CW
EX. 11
4" CW
EX. 21
2" CW
EX. 3
" SAN
EX. 4" SAN
EX. 3 4" CW
EX. 2
" VEX
. 2" V
-
UP
UPUP
3 4 5 6 7 8
A
B
C
D
E
HSL158
HSL157
HSL156
HSL159 HSL162
HSL160 HSL161
HSL154
HSL153
HSL151
HSL150
HSL178A
HSL180
HSL178
HSL176
HSL177 HSL175
HSL172
HSL173HSL171
HSL174
HSL170
HSL169
HSL168
HSL167
HSL155
HSL165
HSL163
HSL152
HSL119HSL118
HSL144
HSL100
HSL100E
HSL100E
T
T
T
T
If you must print this drawing,please recycle
www.soa-inc.com
Missouri Certificate ofAuthority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103Columbia, MO 65202573.443.1407
MEP ENGINEER:
912 Old 63 SouthColumbia, MO 65201
573-875-4365
CE PROJECT COL20003
ISSUE FOR BID
03-19-2020
LOTT
ES 1
ST F
LOO
RR
ENO
VATI
ON
PH
ASE
ON
E1
HO
SPIT
AL
DR
IVE
CO
LUM
BIA
, BO
ON
E C
OU
NTY
, MO
REVISION DATE
Shane Floyd, P.E.PE-2019017814MO Certificate of Authority #2006012388
MARCH 19TH, 2020
0"4'-
0"8'-
0"24
'-0"
16'-0
"1/8
"=1'-0
"
PS101
FIRST FLR. SANITARTYSEWER AND VENT PLAN
PLUMBING PLENUM SPACE NOTESMATERIALS EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTME 84. PLENUM WRAP SHALLBE ALLOWED ON SYSTEMS (PVC) THAT DO NOT MEET FLAME SPREAD/SMOKE DEVELOPED INDEX 25/50 WHERE EXACTCOMBINATION OF PIPE AND WRAP PRODUCTS HAS BEEN TESTED IN THE SIZES TO BE USED.
DF1
WC1LAV1 LAV1 WC1
FD1FD1
FCO
NO WORKTHIS AREA
TIE INTO EXISTING VENT SYSTEMTHIS APPROXIMATE LOCATION.
TIE INTO EXISTING VENT SYSTEMTHIS APPROXIMATE LOCATION.
TIE INTO EXISTING SANITARYTHIS APPROXIMATE LOCATION.
4" SA
N
WCO
4" SAN
4" SAN
2" V
GENERAL NOTES1. REFER TO P501 AND P601 FOR REMAINING POWER NOTES, LEGENDS, DETAILS & SCHEDULES2. ALL PLUMBING FIXTURES AND PIPING LABELED 'EX' OR 'EXISTING' SHALL BE EXISTING TO REMAIN UNLESS NOTED
OTHERWISE.3. ALL EXISTING PLUMBING FIXTURES AND PIPING SHOWN ARE AN APPROXIMATION BASED ON EXISTING PLANS,
SPECIFICATIONS, AND FIELD SURVEYS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS OF PLUMBING FIXTURES ANDPIPING PRIOR TO START OF CONSTRUCTION. PROVIDE REPORT TO OWNERS REPRESENTATIVE OF ALL DEVIATIONS WHICHWILL AFFECT RENOVATION / NEW INSTALLATIONS AS SHOWN ON THE PLANS.
PLENUM SPACE NOTETHIS PROJECT INCLUDES A PLENUM SPACE
CONTRACTORS SHALL USE NON COMBUSTIBLE OR PLENUM RATED MATERIALS ABOVE CEILING:- EMT CONDUIT, CAST IRON SANITARY & VENT PIPING
SEE EACH SHEET FOR SPECIFIC PLENUM NOTES
FIRST FLR. SANITARTY SEWER AND VENT PLANSCALE : 1/8" = 1'-0"
SK12" V
4" SAN
EX. V
ENT
EX. V
ENT
MS1
KEY PLANSCALE: 1" = 60'-0
KEY NOTESDEMO EXISTING DRINKING FOUNTAIN AND CAP EXISTING SANITARY SEWER AND VENT BEHIND FINISHED SURFACE OFWALL.
1
DEMO EXISTING SINK AND CAP EXISTING SANITARY SEWER AND VENT BEHIND FINISHED SURFACE OF WALL.2
TIE INTO EXISTING SANITARYTHIS APPROXIMATE LOCATION.
TIE INTO EXISTING VENT SYSTEMTHIS APPROXIMATE LOCATION.
2" SAN
2" V
EXISTING2" SAN
EX. 3
" SAN
EX. 4" SAN
4" SAN UP IN WALL TO ABOVECEILING AND CAPPED FOR
FUTURE CONNECTION TO 2NDFLR RESTROOMS
4" SA
N
4" SAN
FIRE PENETRATION NOTE THIS PROJECT CONTAINS FIRE RATED ASSEMBLIES. LOCATIONS ARE INDICATED ON ARCHITECTURALPLANS. ALL CONTRACTORS SHALL PROVIDE PROTECTION FOR THEIR PENETRATIONS THRU THESEASSEMBLIES AS FOLLOWS.
FOR ALL PENETRATIONS THRU OR INTO FIRE RATED VERTICAL OR HORIZONTAL ASSEMBLIES:A UL LISTED PENETRATION FIRESTOP SYSTEM SHALL BE INSTALLED AS TESTED INACCORDANCE WITH ASTM E 814 OR UL 1479 (IBC 714.3). GENERAL CONTRACTOR TO PROVIDEAND MAINTAIN A BOOK WITH ALL FIRE PENETRATION PROTECTIVE SYSTEMS THAT WILL BEUSED ON THIS PROJECT. THIS BOOK MUST REMAIN ON SITE AT ALL TIMES.
COORDINATE SANITARY PIPING WITH1ST FLOOR PLAN SAW CUTTING. REFERTO ARCHITECTURAL PLAN SHEET A201.
-
UP
UPUP
3 4 5 6 7 8
A
B
C
D
E
T
T
T
T
If you must print this drawing,please recycle
www.soa-inc.com
Missouri Certificate ofAuthority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103Columbia, MO 65202573.443.1407
MEP ENGINEER:
912 Old 63 SouthColumbia, MO 65201
573-875-4365
CE PROJECT COL20003
ISSUE FOR BID
03-19-2020
LOTT
ES 1
ST F
LOO
RR
ENO
VATI
ON
PH
ASE
ON
E1
HO
SPIT
AL
DR
IVE
CO
LUM
BIA
, BO
ON
E C
OU
NTY
, MO
REVISION DATE
Shane Floyd, P.E.PE-2019017814MO Certificate of Authority #2006012388
MARCH 19TH, 2020
0"4'-
0"8'-
0"24
'-0"
16'-0
"1/8
"=1'-0
"
PW101
FIRST FLR. WATERPIPING PLAN
PLUMBING PLENUM SPACE NOTES
DF1 WC1
LAV1 LAV1WC1
NO WORKTHIS AREA
GENERAL NOTES1. REFER TO P501 AND P601 FOR REMAINING POWER NOTES, LEGENDS, DETAILS & SCHEDULES2. ALL PLUMBING FIXTURES AND PIPING LABELED 'EX' OR 'EXISTING' SHALL BE EXISTING TO REMAIN UNLESS NOTED
OTHERWISE.3. ALL EXISTING PLUMBING FIXTURES AND PIPING SHOWN ARE AN APPROXIMATION BASED ON EXISTING PLANS,
SPECIFICATIONS, AND FIELD SURVEYS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS OF PLUMBING FIXTURES ANDPIPING PRIOR TO START OF CONSTRUCTION. PROVIDE REPORT TO OWNERS REPRESENTATIVE OF ALL DEVIATIONS WHICHWILL AFFECT RENOVATION / NEW INSTALLATIONS AS SHOWN ON THE PLANS.
PLENUM SPACE NOTETHIS PROJECT INCLUDES A PLENUM SPACE
CONTRACTORS SHALL USE NON COMBUSTIBLE OR PLENUM RATED MATERIALS ABOVE CEILING:- EMT CONDUIT, CAST IRON SANITARY & VENT PIPING
SEE EACH SHEET FOR SPECIFIC PLENUM NOTES
FIRST FLR. WATER PIPING PLANSCALE : 1/8" = 1'-0"
TIE INTO EXISTING 21 2" CW LINETHIS APPROXIMATE LOCATION.
11 4" CW
34" CW
11 2" CW
11 4" CW
11 4" CW
34" CW
EX. 3 4" CW
EX. 21 2" CW
EX. 11
4" CW
EX. 21
2" CW
SK1
MS1 3 4" CW
KEY PLANSCALE: 1" = 60'-0
ACCESS PANEL FOR WALL MOUNTEDWC. REFER TO ARCHITECTURAL PLANS ACCESS PANEL FOR WALL MOUNTED
WC. REFER TO ARCHITECTURAL PLANS
34" CW
WHA-1
WHA-1
TIE INTO EXISTING CW PIPING INWALL AT DEMO'D SINK LOCATION.
MATERIALS EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTME 84. PLENUM WRAP SHALLBE ALLOWED ON SYSTEMS (PVC) THAT DO NOT MEET FLAME SPREAD/SMOKE DEVELOPED INDEX 25/50 WHERE EXACTCOMBINATION OF PIPE AND WRAP PRODUCTS HAS BEEN TESTED IN THE SIZES TO BE USED.
FIRE PENETRATION NOTE THIS PROJECT CONTAINS FIRE RATED ASSEMBLIES. LOCATIONS ARE INDICATED ON ARCHITECTURALPLANS. ALL CONTRACTORS SHALL PROVIDE PROTECTION FOR THEIR PENETRATIONS THRU THESEASSEMBLIES AS FOLLOWS.
FOR ALL PENETRATIONS THRU OR INTO FIRE RATED VERTICAL OR HORIZONTAL ASSEMBLIES:A UL LISTED PENETRATION FIRESTOP SYSTEM SHALL BE INSTALLED AS TESTED INACCORDANCE WITH ASTM E 814 OR UL 1479 (IBC 714.3). GENERAL CONTRACTOR TO PROVIDEAND MAINTAIN A BOOK WITH ALL FIRE PENETRATION PROTECTIVE SYSTEMS THAT WILL BEUSED ON THIS PROJECT. THIS BOOK MUST REMAIN ON SITE AT ALL TIMES.
-
If you must print this drawing,please recycle
www.soa-inc.com
Missouri Certificate ofAuthority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103Columbia, MO 65202573.443.1407
MEP ENGINEER:
912 Old 63 SouthColumbia, MO 65201
573-875-4365
CE PROJECT COL20003
ISSUE FOR BID
03-19-2020
LOTT
ES 1
ST F
LOO
RR
ENO
VATI
ON
PH
ASE
ON
E1
HO
SPIT
AL
DR
IVE
CO
LUM
BIA
, BO
ON
E C
OU
NTY
, MO
REVISION DATE
Shane Floyd, P.E.PE-2019017814MO Certificate of Authority #2006012388
MARCH 19TH, 2020
0"4'-
0"8'-
0"24
'-0"
16'-0
"1/8
"=1'-0
"
P501
PLUMBING DETAILS ANDSCHEDULES
CENTER LINE
CROSS-SECTON OFHORIZONTAL DRAIN
DRY VENTS TO CONNECT ABOVE CENTER LINEWHERE CONNECTING TO HORIZONTAL DRAIN PIPES
DRY VENT DETAIL
MAIN SERVICESTEEL PIPE
THREAD-O-LET
DIELECTRIC WATERWAY FITTINGVICTAULIC STYLE 647
BRONZE BALL VALVETHD X THD
COPPER UNION(ONLY IF NO UNION
AT EQUIPMENT)COPPER TUBESERVICE BRANCH
232100 DI-ELECTRICWATERWAY INSTALLATION DETAIL
-
UP
UPUP
3 4 5 6 7 8
A
B
C
D
E
LIBRARY
CONFERENCE
HSL163CLASSROOM
HSL144MECHANICAL
HSL174BREAK RM
HSL178ATELECOM
M
M
M
VD
T
T
T
T M
M
M
M
urgent
T
T T
T
T
VAV103
(EXISTING)
EX. 1
4x8EX
. 14x8
EX. 1
4x8
EX. 1
4x8
VAV122
(EXISTING)
GENERAL NOTES1. REFER TO M501 AND M601 FOR REMAINING HVAC NOTES, LEGENDS, DETAILS & SCHEDULES2. ALL HVAC DUCTWORK SHOWN SHALL ROUTE IN SPACE ABOVE CEILING(S) UNLESS NOTED OTHERWISE.3. ALL EQUIPMENT, DUCTWORK, AND DEVICES LABELED 'EX.' OR 'EXISTING' SHALL BE EXISTING TO REMAIN UNLESS NOTED
OTHERWISE.4. ALL EXISTING EQUIPMENT, DUCTWORK, AND DEVICES SHOWN ARE AN APPROXIMATION BASED ON EXISTING PLANS,
SPECIFICATIONS, AND FIELD SURVEYS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS OF EQUIPMENT, DUCTWORK,AND DEVICES PRIOR TO START OF CONSTRUCTION. PROVIDE REPORT TO OWNERS REPRESENTATIVE OF ALL DEVIATIONSWHICH WILL AFFECT DEMOLITION AS SHOWN ON THE PLANS.
5. CONTACT OWNER AT LEAST 7 DAYS BEFORE DEMOLITION WORK BEGINS. OWNER TO REMOVE CONTROLS.6. FC BUS SHALL REMAIN INTACT THROUGHOUT CONSTRUCTION. COORDINATE OUTAGES WITH OWNERS REPRESENTATIVE.
MD101
FIRST FLR. HVACDEMOLITION PLAN
KEY NOTES
If you must print this drawing,please recycle
www.soa-inc.com
Missouri Certificate ofAuthority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103Columbia, MO 65202573.443.1407
MEP ENGINEER:
912 Old 63 SouthColumbia, MO 65201
573-875-4365
CE PROJECT COL20003
ISSUE FOR BID
03-19-2020
LOTT
ES 1
ST F
LOO
RR
ENO
VATI
ON
PH
ASE
ON
E1
HO
SPIT
AL
DR
IVE
CO
LUM
BIA
, BO
ON
E C
OU
NTY
, MO
REVISION DATE
Shane Floyd, P.E.PE-2019017814MO Certificate of Authority #2006012388
MARCH 19TH, 2020
0"4'-
0"8'-
0"24
'-0"
16'-0
"1/8
"=1'-0
"
MECHANICAL PLENUM SPACE NOTESMECHANICAL:
MATERIALS EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOTMORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84.
EXCEPTIONS:1. RIGID AND FLEXIBLE DUCTS AND CONNECTORS SHALL CONFORM TO SECTION 603 OF THE 2018 INTERNATIONAL
MECHANICAL CODE.2. DUCT COVERINGS, LININGS, TAPE AND CONNECTORS SHALL CONFORM TO SECTIONS 603 AND 604 OF THE 2018
INTERNATIONAL MECHANICAL CODE.3. THIS SECTION SHALL NOT APPLY TO SMOKE DETECTORS.
DEMO SIDEWALL SUPPLY DIFFUSER AND PREP. DUCT FOR NEW CONNECTION.
FIRST FLR. HVAC DEMOLITION PLANSCALE : 1/8" = 1'-0"
1
CFM / FACE SIZE
HVAC SYMBOL LEGENDTYPE OF EQUIPMENT (SEE EQUIPMENT SCHEDULE)REFERENCE NUMBER
TYPE OF DIFFUSER (SEE DIFFUSER SCHEDULE)
SUPPLY DIFFUSERIF OTHER THAN 4-WAY, SHADING INDICATES NO FLOW ZONE
RETURN GRILLE
BALANCE DAMPER
SUPPLY DUCT
RETURN DUCT
EXHAUST DUCT
THERMOSTAT
OUTSIDE AIR DUCT
VENT / COMBUSTION AIR
CONDENSATION LINE
MOTORIZED DAMPER
HVAC DEMO LINE
TIE INTO EXISTING
RETURN DUCT SMOKE DETECTORWIRED TO FAN STARTER TO SHUT UNIT(S) DOWN AND SEND ALARM SIGNALTO FIRE ALARM SYSTEM ( IF PRESENT ) OR TO REMOTE SOUNDER LOCATEDIN AN OCCUPIED SPACE. ( EQUAL TO SYSTEM SENSOR #D4120)
CO2 DETECTOR
FIRE RATED DAMPER
FIRE SMOKE DAMPER
CEILING RADIATION DAMPER
FSD
CRD
FRD
FLEX DUCT
T
DS
CO2
XX
XX
REMOTE SOUNDER WIRED TO RETURN DUCT SMOKE DETECTOR(EQUAL TO SYSTEM SENSOR #MHW).RS
BAROMETRIC RELIEF DAMPERBR
EXISTING SUPPLY DUCT
EXISTING RETURN DUCT
EXISTING EXHAUST DUCT
EXISTING OUTSIDE AIR DUCT
AHU2
(EXISTING)
RHC4
(EXISTING)EX. 16x10EX. 16x10
EX. 1
4x8EX
. 14x8
EX. 14x12 EX. 14x12EX. 12x10
VAV104
(EXISTING)
VAV105
(EXISTING)VAV106
(DEMO)
VAV120
(DEMO)
EX. 16x14EX. 8"
GRILLE TO BE REMOVED AND RELOCATED IN THIS AREA. SEE M101 FOR NEW LOCATION.2
SHIFT GRILLE INTO NEW CEILING GRID. SEE M101 FOR NEW GRILLE LOCATION.3
3
3
3
3VAV118
(DEMO)
VAV117
(DEMO)
VAV114
(DEMO)
VAV115
(EXISTING)
VAV116
(DEMO)
RHC3
(DEMO)
3
5
2
EX. 30x8
EX. 8
"
EX. 6"
EX. 1
0x8
DEMO 6" FLEX
VAV113
(DEMO)
EX. 1
0x8EX
. 14x8
EX. 28x10
EX. 16x16
EX. 20x26
EX. 36x28
EX. 1
8x18
EX. 1
8x18
EX. 1
6x14
VAV-
(EXISTING)
VAV112
(EXISTING)
EX. 18x12
VAV107
(EXISTING)
VAV111
(EXISTING)
EX. 12x10
EX. 6"
EX. 12"
EX. 1
8x14
EX. 1
4x12
EX. 1
2x10
EX. 1
0x8
EX. 14x12EX.
8"EX
. 12x1
0
EX. 1
4x8EX
. 14x8
EX. 10x8
EX. 1
8x18
VAV110
(EXISTING)
VAV109
(EXISTING)
VAV108
(EXISTING)
EX. 8"
EX. 5"
EX. 5" EX. 8"
EX. 8x6
EX. 5"
EX. 5"
EX. 5"EX. 5"
EX. 5" EX. 5"
EX. 5"
EX. 8x8EX. 7"
EX. 6
" EX. 6"
EX. 8"
EX. 5"EX. 8"EX. 6"
EX. 6"
EX. 8"EX. 8"
EX. 1
0"
3
1
1
1
1 1
1
2
DUCTWORK SHALL BE DEMO'D4
GRILLE/ DIFFUSER SHALL BE DEMO'D5
4
4
4
4 4
44
4 4 4
4
4
4
4
4
4
4
4
4
4
4
4
44
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5 5
5 5
5
5
5
5
5
5
5 5 5
55
5
4
4
4
4
4VAV119
(EXISTING)
DEMO DUCT MAINTRUNK AND PREP FOR
NEW CONNECTION.
4
KEY PLANSCALE: 1" = 60'-0
4
4
2
2
EX. 1
4x8
ALTERNATE BID #2CONTRACTOR SHALL PROVIDE ALTERNATE PRICE FOR WORKTHIS AREA UNDER "ALTERNATE BID #2". SEE ARCHITECTURAL
PLANS FOR ADDITIONAL ALTERNATE BID #2 INFORMATION.
PROVIDE ALTERNATE PRICE TO REMOVE AND SALVAGE GRILLE TO BE REINSTALLED AT SAME LOCATION IN NEW CEILINGGRID. SEE SHEET M101.
6
6 6 6 6 6 6
GENERAL CONSTRUCTION NOTES1. PRIOR TO START OF DEMOLITION, ALL EXISTING VAV BOXES LOCATED IN AREA OF WORK SHALL BE DISCONNECTED FROM
POWER.2. ALL EXISTING RETURN GRILLES LOCATED IN AREA OF WORK SHALL BE COVERED TO PREVENT CONSTRUCTION DUST FROM
ENTERING THE RETURN PLENUM SPACE.
THERMOSTAT TO BE REMOVED AND SALVAGED BY OWNER.7
777
EXISTING THERMOSTAT TO REMAIN.8
8
7
-
UP
UPUP
3 4 5 6 7 8
A
B
C
D
E
LIBRARY
CONFERENCE
HSL163CLASSROOM
HSL144MECHANICAL
HSL174BREAK RM
HSL178ATELECOM
T
T
T
urgent
T
T
7 8
D
201HSL 201
VAV103
(EXISTING)
VAV122
(EXISTING)
If you must print this drawing,please recycle
www.soa-inc.com
Missouri Certificate ofAuthority Number: 000826
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103Columbia, MO 65202573.443.1407
MEP ENGINEER:
912 Old 63 SouthColumbia, MO 65201
573-875-4365
CE PROJECT COL20003
ISSUE FOR BID
03-19-2020
LOTT
ES 1
ST F
LOO
RR
ENO
VATI
ON
PH
ASE
ON
E1
HO
SPIT
AL
DR
IVE
CO
LUM
BIA
, BO
ON
E C
OU
NTY
, MO
REVISION DATE
Shane Floyd, P.E.PE-2019017814MO Certificate of Authority #2006012388
MARCH 19TH, 2020
0"4'-
0"8'-
0"24
'-0"
16'-0
"1/8
"=1'-0
"
FIRST FLR. HYDRONIC DEMO PLANSCALE : 1/8" = 1'-0"
AHU2
(EXISTING)
RHC4
(EXISTING)VAV104
(EXISTING)
VAV105
(EXISTING) VAV106
(DEMO)
VAV119
(EXISTING)
VAV109
(EXISTING)
VAV118
(DEMO)
VAV117
(DEMO)
VAV115
(EXISTING)
VAV116
(DEMO)
VAV113
(DEMO)
VAV112
(EXISTING)
VAV107
(EXISTING)
VAV111
(EXISTING)
VAV110
(EXISTING)
VAV108
(EXISTING)
GENERAL NOTES1. REFER TO M501 AND M601 FOR REMAINING HVAC NOTES, LEGENDS, DETAILS & SCHEDULES2. ALL NEW PIPING SHOWN SHALL ROUTE IN SPACE ABOVE CEILING(S) UNLESS NOTED OTHERWISE.3. ALL EQUIPMENT, PIPING, AND DEVICES LABELED 'EX.' OR 'EXISTING' SHALL BE EXISTING TO REMAIN UNLESS NOTED
OTHERWISE.4. ALL EXISTING EQUIPMENT, PIPING, AND DEVICES SHOWN ARE AN APPROXIMATION BASED ON EXISTING PLANS,
SPECIFICATIONS, AND FIELD SURVEYS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS OF EQUIPMENT, PIPING, ANDDEVICES PRIOR TO START OF CONSTRUCTION. PROVIDE REPORT TO OWNERS REPRESENTATIVE OF ALL DEVIATIONS WHICHWILL AFFECT DEMOLITION AS SHOWN ON THE PLANS.
MECHANICAL PLENUM SPACE NOTESMECHANICAL:
MATERIALS EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOTMORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84.
EXCEPTIONS:1. RIGID AND FLEXIBLE DUCTS AND CONNECTORS SHALL CONFORM TO SECTION 603 OF THE 2015 INTERNATIONAL
MECHANICAL CODE.2. DUCT COVERINGS, LININGS, TAPE AND CONNECTORS SHALL CONFORM TO SECTIONS 603 AND 604 OF THE 2015
INTERNATIONAL MECHANICAL CODE.3. THIS SECTION SHALL NOT APPLY TO SMOKE DETECTORS.
MD102
FIRST FLR. HYDRONICDEMO PLAN
RHC3
(DEMO)
EXISTING PIPING SHOWN DASHEDSHALL BE DEMO'D AND CAPPED
HOT WATER SUPPLY
HYDRONIC SYMBOL LEGEND
PIPE LINE TURNED UP / PIPE LINE TURNED DOWN
PUMP
VALVE
TIE INTO EXISTING
HOT WATER RETURN
EXISTING HOT WATER SUPPLY
EXISTING HOT WATER RETURN
HYDRONIC PIPING DEMO
KEY PLANSCALE: 1" = 60'-0
VAV120
(DEMO)
VAV114
(DEMO)
VAV-
(EXISTING)
DEMO HOT WATERPERIMETER HEATER.
DEMO HOT WATERPERIMETER HEATER.
DEMO HOT WATERSUPPLY/RETURN PIPINGSERVING PERIMETER HEATERTO ABOVE CEILING AND CAP.SEE M102.
KEY NOTESCAP PIPING ABOVE CEILING THIS LOCATION. DEMO ALL HWS AND HWR FROM BEYOND THIS POINT TO PERIMETER HEATERLABELED TO BE DEMO'D.
1
1
1
SECOND FLR. HYDRONIC DEMO PLANSCALE : 1/8" = 1'-0"
DEMO HOT WATERPERIMETER HEATER.
DEMO HOT WATERSUPPLY/RETURN PIPINGSERVING PERIMETER HEATERTO ABOVE CEILING AND CAP.SEE M102.
1
-
3 4 5 6 7 8
A
B
C
D
E
HSL151
HSL153
HSL155
HSL161HSL160
HSL162HSL159
HSL158
HSL157
HSL156
HSL155
HSL155
HSL154
HSL163
HSL165
HSL167
HSL168
HSL169
HSL170
HSL171 HSL173
HSL174
HSL144
HSL177 HSL175
HSL150 HSL178
HSL178A HSL180
HSL176
HSL100E
HSL100E
HSL100
M
T
T
T
T
T
T
M
M
VD
M
M
M
M
FRD
FRD
FRD F