ltg high performance tangential fans - deutsche messe ag

8
LTG High Performance Tangential Fans Even airflow over large areas Temperature range from -40 °C to +800 °C (-40 °F to +1500 °F)

Upload: others

Post on 18-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

LTG High Performance Tangential Fans

Even airflow over large areasTemperature range from -40 °C to +800 °C (-40 °F to +1500 °F)

Many production processes require an extended linear and absolutely even distribution of air or other gases over a certain area.

The special design of LTG High Performance Tangential Fans provides the optimum solution for these requirements.

The robust design and the use of high quality materials assure a long life expectancy. The way these fans work, allowing even air distribution without additional baffles and vanes, and the space­saving design, make the use of tangential fans very economic.

Flow principle:

In a tangential fan, the air is drawn in over the entire length of the fan impeller. Inside the impeller, the airflow is diverted and accelerated by the vortex created by the rotation of the impeller.

The airstream then exits over the entire length of the impeller on the discharge side. The vortex separates the intake and dis­charge side of the fan at the narrowest point between the impeller and the vortex builder. Together with the fan scroll, the vortex directs the airflow. This results in an almost uniform laminar airflow over the entire outlet width of the fan.

LTG High Performance Tangential Fans To achieve better product quality and to improve the production process

airflow 90°

airflow 180°

Axial

• Fans perform well in any mounting position. Drive can be mounted on right or left hand side.

• Quiet operation due to optimised impeller and housing design.

• Long life expectancy due to robust design and location of bearings outside the hot air zone.

• Explosion-proof models according to ATEX available.

Advantages:

• Uniform, extended airflow over large areas.

• Space-saving installation due to 90° and 180° airflow pattern.

• Fan length can be matched exactly to machine width.

• Airflow conditions remain the same even for wider machines (simplified design and drafting in case of modular systems).

Choose LTG High Performance Tangential Fans

LTG High Performance Tangential Fans: easy to incorporate into your design

In various industries, tangential fans provide effective cooling, heating or drying. This assures a flawless function and quality improvement of machinery and equipment. The specific design of the tangential fan saves space and provides the designer with a lot of freedom during the design process.

Complicated additional air guidance systems, such as ducts or guide vanes to optimise the air or temperature distribution, are not required. The whole assembly can be produced smaller, more compact, saving a lot of space.

LTG Aktiengesellschaft offers fans for all airflow patterns:the best prerequisite for objective technical advice.

Centrifugal

Tangential

LTG High Performance Tangential Fans

Type GA 25 Impeller diameter: 25 mm / 1.0 inImpeller length: 210 mm / 8.3 in

Type TA h 60Impeller diameter: 60 mm / 2.36 inImpeller length: 145–615 mm / 5.7–24.2 inalso available with heating element

Type GA 90Impeller diameter: 90 mm / 3.5 inImpeller length: 397–1227 mm / 15.6–48.3 in

Type TM 125Impeller diameter: 125 mm / 4.9 inImpeller length: 400–1000 mm / 15.8–39.4 in

Type TW 150Impeller diameter: 150 mm / 5.9 inImpeller length: 401–1464 mm / 15.8–57.6 in

Type VQImpeller diameter: 150–1000 mm / 5.9–39.4 inImpeller length: 400–4500 mm / 15.8–177.2 in

Our extensive product range

series

GA

TA

TA t

TE t

TW

TM

TM t

TTF

VQ

impeller diameter

25–90 mm1.0–3.5 in

40–90 mm1.6–3.5 in

90 mm3.5 in

40–90 mm 1.6–3.5 in

125–200 mm4.9–7.9 in

125–200 mm4.9–7.9 in150 mm5.9 in

150 mm5.9 in

150–1000 mm 5.9–39.4 in

impellerlength

210–1227 mm8.3–48.3 in

95–1227 mm3.7–48.3 in

397–597 mm15.6–23.5 in

95–727 mm3.7–28.6 in

400–1464 mm15.8–57.6 in

400–1464 mm15.8–57.6 in401–1064 mm15.8–41.9 in

401–1264 mm15.8–49.8 in

400–4500 mm15.8–177.2 in

air/gas temperature

-40 to +70 °C-40 to +160 °F

-40 to +70 °C-40 to +160 °F

-40 to +120 °C-40 to +250 °F

-40 to +300 °C-40 to +600 °F

-25 to +120 °C-15 to +250 °F

-25 to +70 °C-15 to +160 °F-25 to +120 °C-15 to +250 °F

-25 to +250 °C-15 to +500 °F

-25 to +800 °C-15 to +1500 °F

max. air volume

1600 m3/h940 cfm

1860 m3/h1100 cfm

900 m3/h530 cfm

1200 m3/h700 cfm

15 000 m3/h8800 cfm

15 000 m3/h8800 cfm12 000 m3/h7000 cfm

12 000 m3/h7000 cfm

300 000 m3/h17 6600 cfm

max. stat. pressure

50 Pa0.2 in H2O

100 Pa0.4 in H2O

50 Pa0.2 in H2O

100 Pa0.4 in H2O

600 Pa2.4 in H2O

600 Pa2.4 in H2O500 Pa2 in H2O

500 Pa2 in H2O

3000 Pa12 in H2O

specification

• airflow 180° • direct drive with motor• housing: aluminium, stainless steel• impeller: galvanised steel or

aluminium

• airflow 90°• direct drive with motor• housing: aluminium, stainless steel• impeller: aluminium • impeller diameter 60 mm / 2.36 in

available with heating element

• airflow 90°• direct drive with motor• housing: stainless steel• impeller: stainless steel

• airflow 90°• shaft end on drive side• housing: aluminium, stainless steel• impeller: galvanised steel

• airflow 90°• direct drive with motor• housing: aluminium, stainless steel• impeller: galvanised steel

• airflow 90°• shaft end on both sides• housing: aluminium, stainless steel• impeller: galvanised steel

• airflow 90°• shaft end on drive side• housing: galvanised steel or

stainless steel• impeller: galvanised steel or

stainless steel

With impeller diameters from 25 to 1000 mm (1.0 to 39.4 in) and nominal lengths from 95 to 4500 mm (3.7 to 177.2 in), we always have a suitable LTG High Performance Tangential Fan for your application.

Customer-specific solutions on request.

Successful applications in many industriesOptimum cooling, heating, drying and cleaning

agricultural technologyair-conditioning technologyapparatus engineeringautomotive industrybakery technologybiomedical industrybuilding material industrychemical industry cleaning technology

control panel technologydedusting technologydrying technologyelectronic industryenvironmental simulationsfood industryfurnace technologyheat treatment technologymechanical and plant engineering

medical technologypackaging industrypaper industrypharmaceutical industry power plant engineeringprocess engineeringrailway technologyrefrigeration technologystore design

surface technologyswimming pool technolgy textile machinery designtobacco industrytransportation cooling wood industry…

Applications of LTG High Performance Tangential Fans

heat treatment technology

furnace technology packaging industry

electronic industrydrop forge

cooling of hybrid components material testing

automotive industry

LTG Engineering ServicesMake use of our knowledge to solve your problems

Whether you are designing a production facility, a building or a machine, our highly qualified engineers will assist you with your ventilation, airflow and air conditioning problems from the very start.

As professionals, we can provide everything you need for opti-mum implementation of your project: individual advice, broad know-how and the necessary tools, for example, a fully equipped R&D lab.

Our services• We analyse your existing systems, machinery and processes.

• Together with you, we define your requirements, taking all the relevant parameters into account.

• To find solutions, we use our broad know-how plus numerical and experimental flow analysis.

• The result: solutions that are tailored according to your needs. For example, we optimise the airflow in your process and maximise your energy efficiency.

Experimental flow investigations and optimisationThe visualisation of airflow on site or in an LTG flow laboratory, at reduced or original scale, provides certainty. Process parameters like air speed, pressure and temperature can be optimised. We apply the results of CFD simulations to the given situation and verify them with the product or process.

Acoustic optimisationMeasurements of your product’s acoustic power level in LTG’s reverberant echo chamber are part of our engineering services. Here we analyse sound spectra and optimise your product’s acoustic properties in a systematic manner. Additionally, we measure sound pressure levels on site at your workstations and systems.

On-site measurementsOur specialists determine the parameters of the existing system on site. Based on these parameters, together with you, we define your requirements and suggest ways to solve your particular problem. This information is used for numerical flow simulations and experimental verification.

Computational Fluid Dynamics (CFD)Computational fluid dynamics permits the calculation and visu-alisation of airflow for existing or planned systems and processes. By varying different parameters we develop reliable, innovative flow concepts and significantly shorten the development time.

LTG AktiengesellschaftGrenzstrasse 7D-70435 StuttgartTel: +49 (711) 8201-0Fax: +49 (711) 8201-696E-mail: [email protected]: www.LTG-AG.de

450-29 (04/11) Subject to technical modifications. © LTG Aktiengesellschaft, Stuttgart

Room Air Technology

Air Diffusers• Linear Air Diffusers• Wall and Floor Mounted Air

Diffusers• Swirl Diffusers• Industrial and Special Air

Diffusers

Air Conditioning Systems• Decentralised Façade

Ventilation Unit• Fan Coil Units• Induction Units,

Active Chilled Beams

Air Distribution• Flow Rate and Pressure

Controllers• Shut-off and Balancing Dampers• Silencers

Process Air Technology

Fans• Tangential Fans• Axial Fans• Centrifugal Fans• Fahrtwind-Simulators

Filtration Technology • Suction Nozzles• Dampers• Filters, Dust Collectors• Separators, Compactors

Humidification Technolgy• Air Humidifiers • Product Humidifiers

Engineering Services

Fluid Engineering• Flow analysis on a scale of 1:1• Flow visualisation• Small scale tests• CFD simulations• Experimental flow optimisation• Comfort measuring on site• Optimisation of air conditioning

concepts

Thermodynamics• Calorimetric performance

measurement• Thermal, dynamic, unsteady system

simulations• CFD simulations

Acoustics• Sound level measuring• Vibration analysis• Echo chamber measurement• Acoustic optimisation

Customer-specific Solutions• Product development• Process optimisation• Installation analysis

LTG Incorporated105 Corporate Drive, Suite ESpartanburg, SC 29303, USATel: +1 (864) 599-6340Fax: +1 (864) 599-6344E-mail: [email protected]: www.LTG-INC.net

LTG S.r.l. con socio unicoVia G. Leopardi, 10I-20066 Melzo (Mi)Tel: +39 (02) 955-0535Fax: +39 (02) 955-0828E-mail: [email protected]: www.LTG-SRL.com

Toho Engineering Co., Ltd.14-11, Shimizu 3-Chome, Kita-KuNagoya 462-0844, JapanTel: +81 (52) 991-1040Fax: +81 (52) 914-9822E-mail: [email protected]: www.tohoeng.com