m03 6720 hw overview

50
VDX 6720 Hardware Overview PR206 3 - 1 Revision 0111

Upload: brenohenrique

Post on 24-Dec-2015

22 views

Category:

Documents


5 download

DESCRIPTION

M03 6720 HW Overview

TRANSCRIPT

Page 1: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 1Revision 0111

Page 2: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 2Revision 0111

Page 3: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Check release notes for scalability numbers.

3 - 3Revision 0111

Page 4: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 4Revision 0111

Page 5: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

One LED (green) to indicate valid system power.

One LED (green/amber) to indicate system status.

Console Port: RJ-45 port using RS-232 for console access such as configuring the switch and maintenance.

Out of Band Management: RJ-45 Ethernet port for out-of-band management.g p g

Two Ethernet LEDs (integrated with RJ45 connector) to indicate speed and link status.

* RLOM port: Remote Lights Out Management (RLOM) port for switch management (for future use - disabled). Review the release notes for when this feature will be available.

USB port: Brocade branded USB only, used for firmware management and downloading system support (log) information.system support (log) information.

Switch ID and MAC Address tab: Switch ID pull-out tab containing serial number and MAC address.

SFP+ ports: 24 1/10 Gbps SFP+ ports.

Port LEDs (green/amber) to indicate status for each port

3 - 5Revision 0111

Page 6: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Note: The illustration shows only port numbers, not port groups. Port groups are described later in this module.

3 - 6Revision 0111

Page 7: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

LED: Indicates power is on or off.

3 - 7Revision 0111

Page 8: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

One LED (green) to indicate valid system power.

One LED (green/amber) to indicate system status.

Console Port: RJ-45 port using RS-232 for console access such as configuring the switch and maintenance.

Out of Band Management: RJ-45 Ethernet port for out-of-band management.g p g

Two Ethernet LEDs (integrated with RJ45 connector) to indicate speed and link status.

* RLOM port: Remote Lights Out Management (RLOM) port for switch management (for future use - disabled). Review the release notes for when this feature will be available.

USB port: Brocade branded USB only, used for firmware management and downloading system support (log) information.system support (log) information.

Switch ID and MAC Address tab: Switch ID pull-out tab containing serial number and MAC address.

SFP+ ports: 60 1/10 Gbps SFP+ ports.

Port LEDs (green/amber) to indicate status for each port.

3 - 8Revision 0111

Page 9: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Note: The illustration shows only port numbers, not port groups. Port groups are described later in this module.

3 - 9Revision 0111

Page 10: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

LED: Indicates power is on or off.

3 - 10Revision 0111

Page 11: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: When ordering FRUs, verify that the part number supports the correct airflow.You must replace a failed unit with the same type of unit. This applies to both power supplies and fan assemblies.

A new FRU must have the same part number (P/N) as the FRU being replaced. The manufacturing P/N is located on the top of the FRU.

The P/N ends in either F (front to back airflow) or R (back/rear to front airflow) You must The P/N ends in either -F (front-to-back airflow) or -R (back/rear-to-front airflow). You must use a replacement FRU that the same airflow designator with the part number.

Additionally, you can use external labels as a guide. Some FRUs are labeled with an airflow symbol on the faceplate to indicate whether the assembly takes in or exhausts air. The symbol also appears on the top of the assembly.

3 - 11Revision 0111

Page 12: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: Fully-loaded Brocade 6720-24 with two integrated fans and powers supply assemblies, and zero SFPs installed. For more information on specifications, review the Brocade 6720 data sheet available from www.brocade.com or review the Brocade 6720 Hardware Reference Manual, 53-1002084.

Footnote 2: Fully loaded VDX 6720 60 with two power supplies three fan assemblies and Footnote 2: Fully-loaded VDX 6720-60 with two power supplies, three fan assemblies, and zero SFPs installed. For more information on specifications, review the Brocade 6720 data sheet available from www.brocade.com or review the Brocade 6720 Hardware Reference Manual, 53-1002084.

3 - 12Revision 0111

Page 13: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 13Revision 0111

Page 14: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 14Revision 0111

Page 15: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: Replacement of the integrated power supply/fan FRU must match the airflow direction of the failed FRU. If the airflow does not match, a warning message is generated.

Footnote 2: Replacement power supply or fan must match airflow direction of the failed FRU.

When ordering FRUs, verify that the part number supports the correct airflow. You must replace a failed unit with the same type of unit This applies to both power supplies and fan replace a failed unit with the same type of unit. This applies to both power supplies and fan assemblies.

A new FRU must have the same part number (P/N) as the FRU being replaced. The manufacturing P/N is located on the top of the FRU.

The P/N ends in either -F (front-to-rear airflow) or -R (rear-to-front airflow). You must use a replacement FRU that the same airflow designator with the part number.p g p

Additionally, you can use external labels as a guide. Some FRUs are labeled with an airflow symbol on the faceplate to indicate whether the assembly takes in or exhausts air. The symbol also appears on the top of the assembly.

3 - 15Revision 0111

Page 16: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: An FCoE license enables FCoE on the Brocade VDX 6720 platforms. Since FCoErequires a VCS fabric, a VCS Fabric license is a prerequisite for enabling FCoE in a fabric with more than two switches. In addition, a separate FCoE license is required to enable FCoE on a VCS edge port. Without an FCoE license, FCoE logins are not permitted, and all FCoE commands with the exception of a few commands return an error of “No FCoE license present” when executed.

Footnote 2: A Dynamic POD license allows you to instantly scale the fabric by provisioning additional ports on the Brocade VDX 6720 platforms. Licenses are assigned dynamically from a pool of resources based on auto-detection of active links.

3 - 16Revision 0111

Page 17: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Note: For the VDX 6720-24, ports 1 through 16 are enabled by default. For the POD license, ports 17 through 24 are enabled.

For the VDX 6720-60, the bottom row of ports, 1 through 40, are enabled by default. For the first POD license, ports 41 through 50 are enabled. For the second POD license, ports 51 to 60 are enabled.

3 - 17Revision 0111

Page 18: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 18Revision 0111

Page 19: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: The management port 10/100/1000 Ethernet (RJ-45) includes two LEDs: link and activity. For link, on indicates link is active, off indicates no link. For Activity, blinking indicates activity and off indicates no activity.

RLOM: Not supported in this release

The serial port parameters are fixed at the following: • 9600 baud• 8 data bits• No parity• No hardware flow controlNo hardware flow control

The USB port is used for Brocade branded-USB drives which are used for firmware download and storing support information such as logs.

3 - 19Revision 0111

Page 20: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 20Revision 0111

Page 21: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1:• Switching bandwidth from switch backplane (data rate at full duplex):

– 6720-24: 480 Gbps– 6720-60: 1200 Gbps

• Forwarding bandwidth from ports (data rate at full duplex):– 6720-24: 358 Mpps (Million packets per second: used in measuring forwarding rate pp ( p p g g

and forwarding bandwidth)– 6720-60: 896 Mpps

• Port-to-port latency: – 600 ns

3 - 21Revision 0111

Page 22: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 22Revision 0111

Page 23: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

As shown above, VDX 6720-24 platform contains one eAnvil2 ASIC. Each eAnvil2 ASIC supports a Routing Engine (RTE) and each RTE supports 24-1 or 10 Gbps Ethernet ports. Every packet coming in through the external SFP+ interfaces destined to external ports are switched in a single stage within the eAnvil2 ASIC.

The data path is also applicable to packets originated by the CPU which need to go out of the network ports.

The latency for port-to-port communication is 600ns .

3 - 23Revision 0111

Page 24: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

The six front facing eAnvil2 ASICs support local switching. For example, if port 1 needs to send the data to port 2, the packet can be switched locally within a single eAnvil2 ASIC and does not require inter-ASIC switching

Unlike the VDX 6720-24 design, the incoming packets on SFP+ ports destined to an external port now go through three different eAnvil2 ASICs if the source and destination port are on diff A il2 ASICdifferent eAnvil2 ASICs

3 - 24Revision 0111

Page 25: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 25Revision 0111

Page 26: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 26Revision 0111

Page 27: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 27Revision 0111

Page 28: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: For information on updated optic (transceiver) part numbers, go to www.brocade.com. Search on the phrase, transceivers, to locate information on available optics and part numbers.

3 - 28Revision 0111

Page 29: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 29Revision 0111

Page 30: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 30Revision 0111

Page 31: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 31Revision 0111

Page 32: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 32Revision 0111

Page 33: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 33Revision 0111

Page 34: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: The following items are required for configuring and connecting the VDX for use in a network and fabric:• VDX installed and connected to a power source• Workstation with an installed terminal emulator, such as HyperTerminal• Two unused IP addresses and corresponding subnet masks and gateway addresses.

(One for the virtual IP address on the cluster interconnect and another for the management port.)

• Serial cable (provided)• Three Ethernet cables• SFPs and compatible cables, as required• Access to an FTP server for backing up the switch configuration (optional)• A USB stick for collecting the support data (optional). Only those commands supported

by Network OS, such as copy support-interactive. Refer to the troubleshooting module later in this course for specific commands and their usage.

Footnote 2: Follow the installation instructions shipped with the applicable rack mount kit.

Footnote 3: When mounting into a slide-rail rack, you can mount the chassis to slide from either the port side or the non-port side.

3 - 34Revision 0111

Page 35: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 35Revision 0111

Page 36: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 36Revision 0111

Page 37: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: On the non-port side of the switch enclosure, each power supply/Fan FRU has a green/amber LED to indicate the status of the FRU. A steady green light indicates that the FRU is on and operating normally. If there is an amber light, the power is faulty.

3 - 37Revision 0111

Page 38: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: Power is supplied to the switch as soon as the first power supply is connected and powered on.

Footnote 2: All devices are returned to their initial state the next time the switch is powered on.

3 - 38Revision 0111

Page 39: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 39Revision 0111

Page 40: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

For more information, refer to the Brocade VDX 6720 Switch Power Supply/Fan Assembly Replacement Procedure.

Footnote 1 : If the airflow does not match, a warning message is generated. Below are example warning messages:

WARNING, Brocade6720, MISMATCH in PSU-FAN FRUS Air Flow direction Replace PSU with fan air flows in same directiondirection. Replace PSU with fan air flows in same direction.

WARNING, Brocade6720, MISMATCH in FAN Air Flow direction. Replace FRU with fan air flows in same direction.

3 - 40Revision 0111

Page 41: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 41Revision 0111

Page 42: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: On the non-port side of the switch enclosure, each power supply FRU has a green/amber LED to indicate the status of the FRU. A steady green light indicates that the FRU is on and operating normally. If off, then no AC power. If there is an amber light, the power is faulty. If off, then normal operation.

3 - 42Revision 0111

Page 43: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: If the airflow does not match, a warning message is generated. Below are example warning messages:

WARNING, Brocade6720, MISMATCH in PSU-FAN FRUS Air Flow direction. Replace PSU with fan air flows in same direction.

WARNING, Brocade6720, MISMATCH in FAN Air Flow direction. Replace FRU with fan air flows in same directionReplace FRU with fan air flows in same direction.

3 - 43Revision 0111

Page 44: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 44Revision 0111

Page 45: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: The three fan FRUs are designed as hot-swappable in a redundant N+1 configuration to ensure that the VDX 6720-60 continues to operate indefinitely and non-disruptively in the event of a single fan FRU failure.

Footnote 2: On the non-port side of the switch enclosure, each fan FRU has a green/amber LED to indicate the status of the FRU. A steady green light indicates that the FRU is on and operating normally. If off, then there is no AC power. If there is an amber light, the fan is faulty. If off, then that indicates normal operations.

3 - 45Revision 0111

Page 46: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

Footnote 1: If the airflow does not match, a warning message is generated. Below are examples of warning messages:

WARNING, Brocade6720, MISMATCH in PSU-FAN FRUS Air Flow direction. Replace PSU with fan air flows in same direction.

WARNING, Brocade6720, MISMATCH in FAN Air Flow direction. Replace FRU with fan air flows in same directionReplace FRU with fan air flows in same direction.

3 - 46Revision 0111

Page 47: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 47Revision 0111

Page 48: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 48Revision 0111

Page 49: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 49Revision 0111

Page 50: M03 6720 HW Overview

VDX 6720 Hardware OverviewPR206

3 - 50Revision 0111