manifolds - instrumart€¦ · transmitter connection is 1/2“-14 npt male and process connection...

4
MANIFOLDS EDS5-F03f DATASHEET Date September 2016 The FUJI FCX-AII differential, gauge and absolute pressure transmitters can be direct mounted with different kinds of manifold, adapted for the application and the type of transmitter. The manifolds can be delivered mounted on the transmitters or supplied separately. When supplied mounted, the complete assembly is fully pressure tested, and calibrated in the factory. Technical information Material : Standard : Stainless steel 316 for manifold body and valves. Carbon steel : for quantities of 30 or more (consultFuji). Upon request : body material in Monel, Duplex,Hastelloy, etc... Bolts material : stainless steel 316. Gasket : PTFE (standard), Grafoil, Kevlar etc... Bolting size : M10 for static pressure 160 bar max. and gauge pres-sure for 100 bar max. M12 and 7/16 - 20 UNF for 420 bar static and 500 bar gauge pressure. Mounting : Manifold can be mounted on the transmitter. All tests and manufacturing operations will be done with the- manifold : - Pressure test (leakage test) at 1,5 x static pressure for differ- ential pressure transmitter at overpressure rating for gauge and absolute pressure transmitters. - Calibration with factory facilities. Process connection : 1/2”-14 NPT, others upon request. Operating pressure : The maximum pressure is 414 bar (6000 PSI). Upon request, manifolds for maximum pressure 690 bar (10000 PSI) can be delivered. M Code symbols 1 2 3 4 5 Manifolds 2 3 5 6 7 8 9 E Type 1 Valve - type HGVS8F8MPBV-FU - SS316 2 Valves - type HDS2HLH-FU - SS 316 3 Valves - type HDS3DTPPD-FU - SS 316 3 Valves - type HDS3M-FU - SS 316 5 Valves - type HDS5M-FU - SS 316 3 Valves - type flange/flange HFS3-FU - SS 316 2 Valves - type HALS2V-RHV - SS 316 M E Bolting size / matirial 7/16 - 20 UNF - Carbon steel 7/16 - 20 UNF - SS 316 M10 - SS 316 M12 - SS 316 None 0 1 2 3 4 Construction Stainless steel 2 1 Mounted on transmitter Yes No - Separate kit *3 *1 *4 *5 *2 Notes : 1 : For 420 bar static pressure (differential pressure), and 500 bar (gauge pressure), M10 bolting is not suitable, please select 7/16 or M12. 2 : No bolting is necessary for this manifold type. 3 : When manifold is ordered mounted on the transmitter, hydros- tatic pressure test and calibration are made with manifold, so complete set is tested. 4 : Manifold type HDS3M-FU is low cost version of type HDS3DTP- PD-FU. The design of the process connection is smaller. 5 : Supplied with fitting if connection 1/2" NPT Female Fuji Electric France S.A.S.

Upload: others

Post on 18-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MANIFOLDS - Instrumart€¦ · Transmitter connection is 1/2“-14 NPT male and process connection (customer side) is 1/2“ NPT female. It can be direct mounted on FKP transmitter

MANIFOLDS

EDS5-F03f

DATASHEET

Date September 2016

The FUJI FCX-AII differential, gauge and absolute pressure transmitters can be direct mounted with different kinds of manifold, adapted for the application and the type of transmitter.The manifolds can be delivered mounted on the transmitters or supplied separately.When supplied mounted, the complete assembly is fully pressure tested, and calibrated in the factory.

Technical information

Material : Standard : Stainless steel 316 for manifold body and valves. Carbon steel : for quantities of 30 or more (consultFuji). Upon request : body material in Monel, Duplex,Hastelloy, etc... Bolts material : stainless steel 316. Gasket : PTFE (standard), Grafoil, Kevlar etc...

Bolting size : M10 for static pressure 160 bar max. and gauge pres-sure for 100 bar max.M12 and 7/16 - 20 UNF for 420 bar static and 500 bar gauge pressure.

Mounting : Manifold can be mounted on the transmitter. All tests and manufacturing operations will be done with the-manifold : - Pressure test (leakage test) at 1,5 x static pressure for differ-

ential pressure transmitter at overpressure rating for gauge and absolute pressure transmitters.

- Calibration with factory facilities.

Process connection :1/2”-14 NPT, others upon request.

Operating pressure : The maximum pressure is 414 bar (6000 PSI).Upon request, manifolds for maximum pressure 690 bar (10000 PSI) can be delivered.

M

Code symbols

1 2 3 4 5

Manifolds

23

5

6

7

89

E

Type1 Valve - type HGVS8F8MPBV-FU - SS3162 Valves - type HDS2HLH-FU - SS 3163 Valves - type HDS3DTPPD-FU - SS 3163 Valves - type HDS3M-FU - SS 3165 Valves - type HDS5M-FU - SS 3163 Valves - type flange/flange HFS3-FU - SS 3162 Valves - type HALS2V-RHV - SS 316

M E

Bolting size / matirial7/16 - 20 UNF - Carbon steel7/16 - 20 UNF - SS 316M10 - SS 316M12 - SS 316None

0

1

2

3

4ConstructionStainless steel

2

1

Mounted on transmitterYesNo - Separate kit

*3

*1

*4

*5

*2

Notes :1 : For 420 bar static pressure (differential pressure), and 500 bar

(gauge pressure), M10 bolting is not suitable, please select 7/16 or M12.

2 : No bolting is necessary for this manifold type. 3 : When manifold is ordered mounted on the transmitter, hydros-

tatic pressure test and calibration are made with manifold, so complete set is tested.

4 : Manifold type HDS3M-FU is low cost version of type HDS3DTP-PD-FU. The design of the process connection is smaller.

5 : Supplied with fitting if connection 1/2" NPT Female

Fuji Electric France S.A.S.

Page 2: MANIFOLDS - Instrumart€¦ · Transmitter connection is 1/2“-14 NPT male and process connection (customer side) is 1/2“ NPT female. It can be direct mounted on FKP transmitter

2

M

Type HGVS8F8MPBV-FU - 1 valve manifold

Multiport one valve manifold, with separate vent or calibration facilities. Transmitter connection is 1/2“-14 NPT male and process connection (customer side) is 1/2“ NPT female.It can be direct mounted on FKP transmitter or via oval flange (1/2“-14 NPT) on FCX-AII transmitters. Maximum presure : 414 bar (6000 PSI).

Type HDS2HLH-FU - 2 valves manifold

Direct mounted 2 valve manifold delivered with 2 bolts and one PTFE gasket. Both valves have the inlet and drain/vent connection on the mounting face and are suitable for all applications up to 414 bar (6000 PSI).This manifold can be mounted on FCX-AII gauge and absolute pressure transmitter. Process connection is 1/2“-14 NPT female

Type HALS2V-RHV - 2 valves manifold

Direct mounted 2 valve manifold delivered with 2 bolts and one PTFE gasket. Both valves have the inlet and drain/vent connection on the mounting face and are suitable for all applications up to 414 bar (6000 PSI).This manifold can be mounted on FCX-AII gauge and absolute pressure transmitter. Process connection is 1/2“-14 NPT female

OUTLINE DIMENSIONS (unit : mm)

92.0

28.6

28.6

79.4 (OPEN )76.4 (CLOSED)

55.0

1/2-14 NPT (FEM)

1/2-14 NPT(FEM)

ISOLATE VALVE

1/2-14 NPT (MALE)

70.1

63.5

113.0

63.5

114.3 (Open)111.3 (Closed)

28.6

M10 x 1.5p

2 - Ø12.0 MTG. HOLES

M6 x 1.01/4-18 NPT(VENT)

1/2-14 NPT(INLET)

41.3

24.0

8.3

11.2

79.4 [3.125] (OPEN REF.)76.4 [3.008] (CLOSED REF.)

100.2[3.945]

(MAX REF.)

50.8[2.000]

28.6[1.125]1/2-14 NPT

(FEM) INLET1/2-14 NPT (FEM) OUTLET

1/4-18 NPT (FEM) VENT

30.0[1.181]

10.4[0.409]

63.5[2.500]

2-OFF 5.5 [0.217]MTG. HOLES

Page 3: MANIFOLDS - Instrumart€¦ · Transmitter connection is 1/2“-14 NPT male and process connection (customer side) is 1/2“ NPT female. It can be direct mounted on FKP transmitter

3

Type HDS3DTPPD- FU - 3 valves manifold

Alternative solution for 3 valve manifold with some additional facilities like more space for the customer process connec-tion and 2 additional pluged vent ports (1/4“-18 NPT). The 3 valves are mounted in line on the top of the manifold body. Process connections are 1/2“-14 NPT female at 102 mm centers; Maximum pressure 414 bar (6000 PSI).Supplied with 4 bolts and 2 PTFE gaskets

Type HDS3M-FU - 3 valves manifold

This manifold type can be used on the differential pressure and flow transmitters on FCX-AII series.The 2 isolating valves (HP& LPside) are on the body ends of the manifold and the equalising valve on the top.Process connections are 1/2“-14 NPT female at 54 mm (2“ 1/8) centers. Maximum pressure 414 bar (6000 PSI). Supplied with 4 bolts and 2 PTFE gaskets.

147.0

107.8(Open)

63.5

28.6

10.0

35.0

30.0

54.0

102.0

41.3

138.0

4 - Ø12MTG. HOLES

2 - 1/2-14 NPT(INLETS)

2 - M10 x 1.5MTG. HOLES

2 - 1/4-18 NPTDOWNSTREAM TEST

11.214.3

28.6

110.0

211.6 (Open)205.6 (Closed)

2 - M10 x 1.5MTG. HOLES

4 - Ø12MTG. HOLES

54.0

41.3

113.0(Open)

63.5

2 - 1/2-14 NPT(INLET)

30.0

11.2

Page 4: MANIFOLDS - Instrumart€¦ · Transmitter connection is 1/2“-14 NPT male and process connection (customer side) is 1/2“ NPT female. It can be direct mounted on FKP transmitter

M

Fuji Electric can accept no responsibility for possible errors in catalogues, brochures and other printed material. Fuji Electric reserves the right to alter its products without no-tice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. All rights reseved.

Fuji Electric France S.A.S.46 rue Georges Besse - ZI du brézet - 63039 Clermont ferrandTél : 04 73 98 26 98 - Fax : 04 73 98 26 99Mail : [email protected] - web : www.fujielectric.fr

Type HDS5M-FU - 5 valves manifold

This manifold type is used on the diffe-rential and flow transmitters on FCX-AII series. It combines 2 isolating valves (HP& LPside) 2 drain / vent valves and one equalising valve. Suitable for applications up to 414 bar (6000 PSI). Process connections : 1/2“-14 NPT female at 54 mm or (2“ - 1/8) centers. Supplied with 4 bolts and 2 PTFE gaskets.

Type HFS3-FU - 5 valves manifold - Flange/Flange

3 valves and flange/flange manifold used on the differential and flow transmitters on FCX-AII series. The 2 isolating valves (HP& LPside) are on the body ends of the manifold and the equalising valve on the top for applications up to 414 bar (6000 PSI).

239.6 (Open)233.6 (Closed)

113.0(Open)

63.5

28.654.0

138.0

41.3

30.0

2 - 1/2-14 NPT(INLETS)

4 -Ø12MTG. HOLES

2 - 1/4-18 NPT(VENTS)

2 - M10 x 1.5MTG. HOLES

102.0

11.2

85.6

54.0

41.3

187.2 (Open)181.2 (Closed)

67.0

61.5

118.0Max

INLET suitablefor kindly flange

4 - Ø12MTG. HOLES