11/00 - 94858165 - 8666-4118A
Wall-hung gas boilers
CITY 1.24 and 2.24 GNCITY 1.24 and 2.24 B/P
Installation and commissioning manual
ENGLISH
CONTENTS
1. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. MAIN DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52.1 Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.2 Mounting backplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.3 Installed boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3. SCHEMATICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4. CONTROL PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5. HYDRAULIC SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95.1 Circulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95.2 8 litre expansion tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 5.3 12 litre expansion tank (option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
6. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 6.1 Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 6.2 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
6.2.1 Installing the backplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116.2.2 Water and gas connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116.2.3 Water drainage connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126.2.4 Installing the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126.2.5 230 V electrical power supply connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126.2.6 Connection of the Easymatic control or a room thermostat (option) . . . . . . . . . . . . . . . . . . .13
6.3 Pump logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146.4 Fitting the boiler casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
7. PRESSURE SETTING AND CALIBRATED INJECTOR AND DIAPHRAGM MARKINGS . . . . . . . . . . .15
8. COMMISSIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168.1 Pre-commissioning checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168.2 Switching on the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168.3 Filling the installation with water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168.4 Igniting the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168.5 Air bleed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178.6 Adjusting the domestic hot water flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178.7 Adjustment of the maximum holding temperature of the DHW exchanger . . . . . . . . . . . . . . . . . . .178.8 Checks and adjustments in service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
8.8.1 Burner pressure check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188.8.2 Burner safety check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198.8.3 Safety thermostat check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198.8.4 Switching off the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208.8.5 Anti-overflow safety check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
9. MODIFICATION TO USE DIFFERENT GAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
9.1 Removing the burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219.2 Replacing the injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229.3 Replacing the diaphragm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229.4 Replacing the gas assembly modulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229.5 Reassembling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229.6 Adjusting the minimum pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239.7 “Gas type” label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
10. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2410.1 Main heat exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2410.2 Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2410.3 Domestic hot water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2510.4 Cleaning the ”cold water” filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
11. DRAINING DOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
12. ELECTRICAL CIRCUIT DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
13. FAULT CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
14. LIST OF SPARES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
15 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
2
3
CITY 1.24 wall hung gas boilers are for central hea-ting only. They can be associated with 50, 80 or 150litre storage tanks to produce domestic hot water.
CITY 2.24 boilers provide central heating and instan-taneous domestic hot water.
They use natural gas or butane/propane.
CITY 1.24 GN and CITY 2.24 GN boilers are factoryset for use with natural gas.
CITY 1.24 B/P and CITY 2.24 B/P boilers are factoryset for use with butane/propane.
The boiler output can be varied between 10 and 24kW for central heating and 8 and 24 kW for domestichot water.
These boilers are supplied in 2 packs:- backplate pack: water, gas and drain connections(safety valve, disconnector and domestic hot waterpot bleeder on the 2.24 model).- boiler pack.
Note:An extended height backplate must be used for boi-lers associated with an 80 litre tank.
1.2 Approvals
1. GENERAL
1.1 Description
Boiler 2.24 GN 2.24 B/P 1.24 GN 1.24 B/PCE No. CE-0085 AT 0282
Category II 2E+ 3+
Type B 11 BS
Combustion product removal Flue liner
Ignition Automatic
Gas Natural gas Butane/Propane Natural gas Butane/Propane
CITY boilers conform to the following European direc-tives and standards:
90/396 EEC Gas appliance directivesApplicable standards: EN 297 and EN 625.
73/23 EEC Low voltage directivesApplicable standards: EN 60.335.1
89/336 EEC EMC directivesApplicable standards: EN 50.081.1/EN 50.082.1./EN 55.014
92/42 EEC Efficiency directives�� CE
4
1.3 Technical specifications
BOILER 1.24 2.24
Nominal usable output (central heating and hot water modes) kW 24 24Nominal rated output (central heating and hot water modes) kW 26.4 26.4Combustion efficiency % > 92 > 92Minimum usable output (central heating mode) kW 10 10Minimum rated output (central heating mode) kW 11.5 11.5Minimum usable output (domestic hot water mode) kW - 8Minimum rated output (domestic hot water mode) kW - 9.5Maximum temperature (safety thermostat trips out) °C 105 105Weight of boiler without water, backplate, casing kg 30 35Weight of boiler without water, with backplate and casing kg 42 47Shipping weight kg 47 52
Central heating circuitNominal water flowrate (∆T = 20 K) l/h 1034 1034Available head bar 0.1 0.1Outlet temperature °C 40 - 90 40 - 90Maximum pressure bar 3 3Expansion tank l 8 8Initial tank pressure bar 0.75 0.75Minimum working pressure bar 0.3 0.3
Gas flowrate at nominal outputNatural gas H (G20) m3/h 2.79 2.79Natural gas L (G25) m3/h 2.97 2.97Butane (G30) kg/h 2.08 2.08Propane (G31) kg/h 2.05 2.05
Domestic hot waterSpecific hot water flow rate (∆T = 30 K) l/mn - 11.2Setpoint temperature °C - 40 - 60Maximum cold water pressure bar - 10Minimum operating pressure bar - 0.1Minimum pressure for 11 l/min bar - 1.3
Combustion product circuitConnection ø mm 125 125Minimum draw mbar 0.035 0,035Combustion product flowrate (nominal output) kg/h 69.5 69.5Combustion product temperature (nominal output) °C 114 114
Electrical circuitSupply voltage (50 Hz) V 230 230Output consumption W ≅ 80 ≅ 80
1 mbar = 100 Pa1 daPa ~ 1mm H2O
Serial No.
The serial number is on the information plates on theboiler.
8666N175
miniinformationplate
informationplate
173
20
97,5
630
332
15355555555
1000
540
570
A
C
B
Pack A B C
HA 9HA 10
860 375 95
HA 11 890 389 139
5
2. MAIN DIMENSIONS
2.1 Packages
2.2 Mounting backplate
630
173
27,5 20
332
15355555555
Boiler Backplate pack Boiler pack
CITY 2.24 GN HA 10 HA 3CITY 2.24 B/P HA 10 HA 4CITY 1.24 GN (50)* HA 9 HA 1CITY 1.24 B/P (50)* HA 9 HA 2CITY 1.24 GN (80)* HA 11 HA 1CITY 1.24 B/P (80)* HA 11 HA 2
* CITY 1.24 GN and CITY 1.24 B/P central heating boilers can be used in conjunction with a 50 or 80litre storage tank.
If they are associated with an 80 litre storage tankthey can be mounted on an HA 11 increased height backplate so that the front panel of the boiler can be lined up with that of the storage tank.
8666N073
8666N074
8666N075 8666N076
Standard backplate for 1.24 and 2.24 Increased height backplate for 1.24 / 80L
Backplate pack Boiler pack
Pack Number
Pack dimensions
6
2.3 Installed boiler
450 450300
880
= =
CITY 1.24 with increased height backplate(for lining up with 80 litre domestic hot water stora-ge tank)
8666N078
450 380230
880
= =
CITY 1.24 and 2.24
8666N077
Couplingring
internaldiameter125 mm
Couplingring
internaldiameter125 mm
TAF
TS
S1
1
2
M
S2
S3
1
2
M
3132
42
33
22
23
24
25
26
27
28
30
29
34
44
35
36
37
38
6
1 2 3 4 5
6 66
20
19
181716
15
1413
121110
439
8
7
21
7
3. SCHEMATICS
2.24 and 1.24 boilers
8666N016F
CITY 2.24
CITY 1.24
1. Central heating outlet valve2. Domestic hot water outlet valve3. Gas inlet valve4. Cold water inlet valve:
- water flow open / close- flowrate adjustment- filter (removable from below)
5. Central heating return valve6. Drain screw7. Water flowrate sensor8. Domestic hot water outlet sensor9. Domestic hot water heat
exchanger drain screw10. Domestic hot water heat exchan-
ger maintain temperature sensor11. Domestic hot water heat
exchanger air bleed screw12. Central heating / domestic hot
water changeover valve drive motor13. Central heating / domestic hot
water changeover valve14. Electronic pressure gauge15. Degassing chamber16. Circulator motor17. Burner pressure offtake18. Ionisation sensor19. Expansion tank20. Expansion tank inflation valve21. Automatic bleeder22. Anti-backflow draw cup-out23. Combustion product connector24. Combustion product anti-overflow
sensor25. Main heat exchanger26. Central heating outlet temperature
sensor27. Safety thermostat28. Combustion chamber29. Burner30. Igniter electrodes31. Gas valve modulator32. Gas valve safety valves33. Gas supply pressure offtake34. Modulator gas valve35. Domestic hot water heat
exchanger (2.24 only)36. Central heating circuit safety valve37. Central heating circuit by-pass pipe38. Disconnector42. Igniter43. Domestic hot water flow rate
controller (10 l/min)44. Non return valve* If boiler is connected to domestic hotwater storage tank
Centralheatingoutlet
D.H.W. Gasinlet
D.C.W. Centralheatingreturn
Centralheatingoutlet
Domestic*hot water
storage tankprimary outlet
gasinlet
Domestic*hot water
storage tankprimary return
Centralheatingreturn
8
4. CONTROL PANEL
G IH LKJ M
A B2B1B DC E F
8666N020
A. Temperature display- displays the temperature at the central heatingoutlet or the domestic hot water outlet when wateris drawn off.
B. Domestic hot water heat exchanger tempera-ture button (CITY 2.24 only).This function is factory set to the activated position.This provides maximum user comfort.When the boiler is switched on, indicator B2 is onto show that this function is activated.The function can be deactivated, for example in the event of prolonged absence, by pressing but-ton B (indicator B2 turns off). Disconnection of the output supply does not modi-fy the selected operating mode.
Note:- if indicators B1 and B2 are both turned on, theburner has been ignited to heat the domestic hotwater supply.- B2 flashes when the holding position is activatedby bypassing the Easymatic control.
C. Safety indicator
D. Unlocking button- used to reset the boiler from failsafe mode
E. “clean” button- forces operation of the boiler
• press and hold for 5 seconds (display shows )to force the burner to the P min position
• press again (display shows ) to force the burner to the P max (24 kW) position
F. “Installer” button
G. 3-position switch- off/anti-freeze
- central heating and domestic hot water (winter)
- domestic hot water (summer)
H. “Central heating” on indicator- on when the boiler is ignited to heat the water inthe central heating circuit
I. Central heating temperature control- range from 40 to 90°C (click stop at 75°C)
J. Flame present indicator- on when the burner is ignited
K. Domestic hot water temperature control- range from 40 to 60°C (click stop at 55°C)
L. “Domestic hot water” on indicator- on when the burner is ignited to heat the domes-tic hot water supply
M. Pressure indicator- indicates the pressure in the central heating circuit (0.5 to 2.5 bars)
9
5. HYDRAULIC SPECIFICATIONS
5.1 Circulator
The circulator incorporated in the boiler is equippedwith a 3-speed motor with a output consumption of 80 W supply. It is factory-set on high.
RemarkFor boilers also producing domestic hot water (City2.24 or 1.24 plus storage cylinder), the circulator canif required be set on intermediate. It is neverthelessrecommended, for reasons of comfort, to leave it onhigh.
For installations requiring greater hydraulic perfor-mance it is possible to replace the motor with a moreoutputful one (pack HA 209) with a output consump-tion of 93 W.
PV
MV
GV
PV
MV
GV5
6
4
3
2
1
00 200 400 600 800 1000 1200
8666N079
5.2 8 litre expansion tank
CITY boilers are equipped as standard with an 8 litretank (initial pressure 0.75 bar). The total water volu-me is determined in accordance with the static headof the installation and for an average water tempera-ture of 80°C (flow: 90/return:70).
5.3 12 litre expansion tank
Static head 5 6 7 8 9 10in metres up to
Total water 138 129 120 111 102 92
volume
CITY boilers can optionally be fitted with a 12 litreexpansion tank (initial pressure 0.75 bar) (pack HA208).
1. PV : low speed2. MV : medium speed3. GV : high speed
80 W motor93 W motor (option)
6. INSTALLATION
6.1 Regulations
Installation and maintenance regulations
The appliance must be installed and maintained by aqualified professional in accordance with statutoryrequirements.
Establishments receiving the publicInstallation regulations:
The appliance must be installed and maintained inaccordance with statutory requirements.
Static head 5 6 7 8 9 10in metres up to
Total water213 204 195 186 177 167
volume
Flowrate (l/h)
Hea
d (
mcE
)
10
48 cmmini
55 cmmini
S1
30 c
mm
ini
5 cm
10 cmmini *
S2
8666N090
15 mm mini
15 mm mini
- The connection to the flue must be as short anddirect as possible.- Do not install the boiler over a cooker.
8666N089
- The boiler must be fixed to a solid wall capable ofsupporting the weight of the appliance when filledwith water and associated equipments.
- A 15 mm gap on either side of the boiler is sufficientfor removing and replacing the casing. However, a 50 mm gap is recommended to facilitate maintenance.
The installation must comply with applicable regula-tions.
Thermostatic radiator valves must not be used on allradiators.
The CITY boiler incorporates a by-pass assuring aminimum flow of 200 l/h.
- The boiler must not be installed above a heat sour-ce or a cooker.
- The IPX4D protection index authorises installationin bathrooms, but outside protection level 1 and 2volumes.
Radiators in rooms containing a room thermostatmust not be fitted with thermostatic valves.
Ventilation of the room in which the boiler is ins-talled
Fresh air supplyIn the case of direct fresh air entry, the minimum arearequired is 50 cm2.Vitiated air extractionIf the boiler is installed in a kitchen, for example, vitia-ted air from appliances not connected to an extractorpipe (gas cooker, etc.) can be extracted via the drawcup of the boiler. For this it is sufficient for the top ofthe boiler casing to be at least 1.8 m above the floor.
Note:We would draw your attention to the risk of corrosionof boilers installed or near rooms in which the atmos-phere may be polluted by substances containing chlo-rine or fluorine. Examples are: hairdressing salons,industrial premises (solvents), refrigeration plants, etc.The warranty does not cover such installations.
either side ofthe boiler
S1 and S2 : Minimum 600 cm2 unimpeded area10 cm min * : Distance between front of boilerand inside of closure panel
11
6.2.1 Installing the backplate
See the installation instruction sheet supplied in thebackplate pack.
6.2.2 Water and gas connections
With 8 or 12 litre expansion tanks, the connectionscan be made from below, from above or from the rear.
8666N130
Important notes:
• Before connecting the boiler to an existing installa-tion, the installation must be thoroughly rinsed outusing an appropriate product to prevent sludge rea-ching the heater body of the new boiler.
• If different metals are used, such as copper and alu-minium, a corrosion inhibitor must be used.
6.2 Connections
• Central heating connection
Copper bush for connection to 16/18 mm dia. indoortube or 20/22 mm dia. outdoor tube.
• Domestic hot water connection
Copper bush for connection to 14/16 mm dia. indoortube or 18/20 mm dia. outdoor tube.In hard water areas (hardness >25) we recommend awater softener upstream of the boiler.
• Gas connection
Conform to the applicable provisions and in particulargas installation specification. A shut-off valve mustalways be installed as close as possible to the boiler.
The copper bush is for 16/18 mm dia. indoor coppertube.
Operating pressure20 mbar for H natural gas H (G20)25 mbar for H natural gas L (G25)29 mbar for butane (G30)37 mbar for propane (G31)
8666N081
All nested connections to the gas tube must bemade using sleeves purchased off the shelf.
Tube-cutter Connections
From the rear
From above
From below
Centralheating outlet
ø18
D.H.Wø16
Gasinletø18
D.C.Wø16
Centralheating return
ø18
ø18 od ø16 od ø18 od ø16 od ø18 od
ø20 id ø18 id ø18 id ø20 id
1
3
2
4
12
6.2.3 Water drain connection
8666N087
6.2.4 Installing the boiler
2 Offer up the boiler above the valve bracket so thatit backs onto the backplate.
3 Lower the boiler gently. Fit the 5 seals supplied inthe sachet with the manual.
4 Remove the retaining pins and tighten the nuts.
Remove the plastic plugs from the boilerpipes.
1
6.2.5 230 V electrical main supply connection
CITY boilers are fitted with a 3-core main supplycable approximately 1.5 m long.
For correct electrical installation, the appliance mustbe connected to a socket outlet or a circuit includinga 2-pole switch with an open contact spacing greaterthan 3 mm.
mar
ron
sur p
hase
8666N091 A
Electrical connections must be made by aqualified professional.
Note:When connecting to the mains electrical mainsupply, connect the brown wire to live and theblue wire to neutral.If these connections are reversed the ionisa-tion type flame detector will not operate. Theboiler will then go to the fail-safe mode.
P19
The 32 mm diameter “waste water” draina-ge connection supplied with the backplatemust be fitted only after brazing the coppertubes.It is fixed to the left-hand upright of thebackplate using a 12 mm long 4 mm dia-meter screw.Evacuation to a drain is by means of asyphon.
8666N088 B
brown to live
blue to neutral
grenn/yellow to earth
13
6.2.6 Connection of the Easymatic control or a room thermostat (option)
The options are to be connected at the back of thecontrol panel under the small flap.
- Pivot the panel forwards after unscrewing the 2 fas-tening side screws.
- Pull the small flap towards you and ensure that theconnections are in accordance with the selectedoptions.
• Easymatic communicative remote control (box AD 136)
- see the instructions delivered with the Easymaticremote control.
• Programmable room thermostat (box AD 137)
- remove the resistance from the Room Thermo-stat connector- connect, in any order, terminals 1 and 3 of the thermostat to the terminals of the Room Thermo-stat connector.- see also the instructions delivered with the ther-mostat.
• Non-programmable room thermostat (box AD 140)
- remove the resistance from the Room Thermo-stat connector- connect, in any order, terminals 1 and 4 of the thermostat to the terminals of the Room Thermo-stat connector.- see also the instructions delivered with the ther-mostat.
Note : If a room thermostat with 2 dry-contact wireshas been installed, it may be used.
For this:
- remove the resistance from the Room Thermostatconnector
- connect, in any order, the 2 thermostat wires to theterminals of the Room Thermostat connector.
TAMSB
1 2 3
BUS
TAM SB
BUS
8666N094
Remark:
Connections can be with either a 2 wire telephone cableor an electrical section cable of up to 2 x 1,5 mm2.
14
TAMSB
1 2 3
BUS
1 2 3
6.3 Pump Logic
1. In mode (domestic hot water) or in Easymatic
mode (summer), the pump works when domestic hot water is produced (d.h.w), and cutsoff 30 seconds after the d.h.w has been produced;the inversion valve will remain in the d.h.w. posi-tion.
2. In mode (heating + d.h.w.)
A. Without a Room Thermostat or EasymaticThe pump will work continuously.
B. With a Room Thermostat• Switch in position 1:
Continuous operation of the pump.
• Switch in position 2:- The pump cuts off 15 minutes after startingthe Room Thermostat.- After production of d.h.w., if the Room Ther-mostat is started up, the pump cuts off after
30 seconds and the inversion valve remains inthe d.h.w. position.
• Switch in position 3:- The pump cuts off 30 seconds after startingthe Room Thermostat- After production of d.h.w., if the room ther-mostat is started up, the pump cuts off after
30 seconds and the inversion valve remains inthe d.h.w. position.
C. With an Easymatic:• Switch in position 1 or 2:
Continuous operation of the pump.• Switch in position 3:
- When the room temperature is correct, the pump remains in continuous operation.- When the room temperature is too high, thepump cuts off after 15 minutes.- After the production of d.h.w., if the room temperature is too high the pump cuts off after 30 seconds and the inversion valve remains in the d.h.w. position
3. In mode
The pump is stopped.If need be, when the room temperature falls below10° C, the pump will start up to prevent the boilerfrom freezing.
8666N124A
6.4 Fitting the boiler casing
8666N0938666N092
7. PRESSURE SETTING AND CALIBRATED INJECTOR AND DIAPHRAGM MARKINGS
Equipment
Burner pressure and gas flow rate
* 1013 mbar at 15°C
15
Note : fit the front panel after commissioning the boiler.
CITY 1.24 and 2.24
Output nominal minimum
Burner Nat. gas H mbar 6.5 1.0pressure Nat. gas L mbar 7.9 1.4
Butane mbar 19.1 2.5Propane mbar 24.1 3.4
Flow Nat. gas H m3/h 2.79 1.01
rate* Nat. gas L m3/h 2.97 1.07
Butane kg/h 2.08 0.75
Propane kg/h 2.05 0.74
øCITY 1.24 and 2.24 mm
Burner Natural gas H and L 1.35
injectors Butane / Propane 0.8
Diaphragm Natural gas H and L 5.2
Butane / Propane 4.2
16
8. COMMISSIONING
8.2 Switching on the boiler
Check the 3-position switch G is set to “off/anti-free-ze” and then switch on the boiler by plugging in theplug or operating the isolating switch.
8.3 Filling the installation with water
- Open valves 1-2*-4* and 5.
- Check that the automatic bleeder 21 at the top of theexpansion tank is open.
- Fill the installation to a pressure of 1.5 to 2 bars viavalves 38.1 and 38.2.
- Close valves 38.1 and 38.2 when the installationhas been filled with water.
* CITY with domestic hot water production.
8.4 Igniting the boiler
- Set the switch to the position marked .
- If there is a room thermostat or a communicatingremote controller, set it to call for heat.
- Check on the boiler label that it is set up for the gasin use.
- If not, see chapter 9 “Modification to use a differentgas”.
- Open the gas valve 3.
- Take out the 2 fixing screws at the sides and swingthe control panel forward.
- Check the pressure of the gas supply to the boilerat the pressure offtake on the gas valve (33) againstthe information plate.
- Close the gas pressure offtake screw.
- Check for gas and water leaks.
Return the control panel to its original position andreplace the 2 fixing screws at the sides.
8.1 Pre-commissioning checks
3
33
8666N180
G
8666N096
38.1
38.21
2*
4*5 8666N098 B
Commissioning must be carried out by a qua-lified professional
8666N097
17
4.1
8.5 Air bleed
8.6 Adjusting the domestic hot water flow rate(CITY 2.24 only)
Open the stopper of the automatic bleeder inthe top rear corner of the boiler.
Domestic hot water heat exchanger(CITY 2.24 only)
- Bleed the domestic hot water heat exchangerby unscrewing the bleeder slightly.
- To accelerate bleeding, alternate betweencalling for heat and hot water.
- Tighten the bleeder after bleeding the air.
Central heating installation
- Check that all of the installation has been bledcorrectly.
1
2
8666N106 B
8666N105 A
The maximum domestic hot water flow rate is limitedto 10 l/min by the flow rate controller which is moun-ted on the flow rate detector (item 43 § 3).This maximum flow rate can be reduced in 2 ways:
- 1. by adjusting the screw 4.1 (8 mm Allen key),- 2. by replacing the 10 l/min controller with an
8 l/min controller.
The 8 l/min controller (package HA 218) is suppliedwith fitting instructions.
1
2
8.7 Adjustment of the maximum temperature position of the DHW exchanger : TMM(CITY 2.24 only)
The DHW exchanger, when activated, is maintainedat the projected holding temperature DHW - 5° C orat the maximum TMM.
Adjustment Display
- Press the button for 5 seconds (55°C)
- Press repeatedly to select the desiredmaximum temperature position TMM
To exit the display, wait 5 minutes without pressing anything
AE
18
8.8. Checks and adjustments in service
8.8.1 Burner pressure check
- Unscrew the screw inside the burner pressure offta-ke 17 a few turns.
- Connect a pressure gauge to the pressure offtakeand verify that the pressure corresponds to that indi-cated in chapter 7.
17
8666N104 A
8666N107A
- Remember to close the pressure off-take screw 17 after measuring the pres-sure.
- Check the pressure offtake 17 for gasleaks.
Checking the burner pressure at nominal (max)output:
Force the burner to operate at maximum output by
pressing the button marked E :
- Press and hold down the “clean” button E for
5 seconds. The display A indicates .
- Press button E briefly. The display A indicates .
Check that the measured pressure corresponds tothat indicated in chapter 7.
If there is any significant difference, check that theboiler is equipped for the gas supplied as indicated inthe table in chapter 7.
To revert to normal operation press button E briefly.
A C D
19
8.8.2 Burner safety check
- With the burner lit, cut off the gas supply by closingthe shut-off valve.
- Check the reaction of the safety system: the alarm indicator C should turn on and the display
A should alternately indicate and .
- Open the gas valve and press the reset button D.
8.8.3 Safety thermostat check
8666N108 B
The safety thermostat should shut down the boiler ifthe temperature at the central heating outlet exceeds105°C.
AE
AC D
1 5
- Press the “clean” button E for 5 seconds. The dis-
play A shows .
- Press button E briefly. The display A shows .
- Press button E a third time for 5 seconds. Thisforces the burner to minimum output and the display
A indicates alternately and the original tempe-rature.
- Close the central heating flow and return valves 1 and5 using an 8 mm wrench.
The outlet temperature is no longer limited by thecontrol system and the safety thermostat should shutdown the burner.
When the temperature exceeds 100°C and the safe-ty thermostat has not yet tripped, the display indi-
cates alternately and .
- when the burner is shut off by the safety thermostat:• indicator C turns on
• the display alternately indicates and .
- To restart the burner:• open central heating flow and return valves 1and 5• press button D.
8666N219
8666N111 A
8666N218
If the boiler has not shut down 2 minutesafter shutting the valves, disconnect the boi-ler from the mains electrical output supply.
If the burner is turned off, the boiler cools and short-ly afterwards the burner is ignited again and the risein temperature continues:
20
8.8.5 Anti-overflow safety check
If fumes overflow through the anti-backflow device,the anti-overflow safety device 24 disconnects theelectrical output supply to the valve and the boilergoes to its fail-safe mode. The anti-overflow device must be checked on com-missioning the boiler and during annual maintenance.
Check procedure:- Turn off the boiler by setting the 3-position switch Gto “off/anti-freeze”.- Remove the pipe connecting the boiler to the flue.- Using a sheet of metal (or any other heat-resistantmaterial), block the combustion product outlet of theboiler.- Start the boiler; combustion products are evacuatedin the upper part of the boiler via the openings in theanti-backflow device.- The anti-overflow sensor disconnects the electricaloutput supply from the gas valve within 2 minutes.The burner is turned off.- After completing the check, replace the pipeconnecting the boiler to the flue. The boiler restartsautomatically after about 10 minutes.
24
8666N118
Note: To avoid this time delay it is sufficient to switch offthe mains electrical output supply and switch it onagain.
8.8.4 Switching off the boiler
G
8666N096
Set switch G to “off/anti-freeze”:The boiler goes to the standby mode and the display
indicates
Note: In this operating mode only the boiler is protected against freezing.
Disconnect the electrical output sup-ply and the gas supply from the boiler.
8
5
7
6
1
2
3
4
21
9. MODIFICATION TO USE DIFFERENT GAS
The operations described belowmust be carried out by a qualifiedprofessional.
CITY 2.24 GN and 1.24 GN boilers are equipped touse natural gas. CITY 2.24 B/P and 1.24 B/P boilersare equipped to use butane/propane.The procedure from changing from one gas to theother is as follows:9.1 Removing the burner9.2 Replacing the injectors9.3 Replacing the diaphragm9.4 Replacing the gas assembly modulator9.5 Reassembling9.6 Adjusting the minimum pressure9.7 “Gas type” label
9.1 Removing the burner
8666N177
Remove the front panel from the boiler casing (2screws at the top).
Remove the front plate from the combustionchamber (2 screws at the top + 2 wing-nuts).
Disconnect the 2 igniter electrodes.
Disconnect the wire from the ionisation sensor.
2
3
4
1
Remove the anti-radiation plate by pulling itforwards.
Unscrew the 3/4” nut at the top of the gasvalve.
Unscrew the 4 screws fixing the burner to themanifold. Use a magnetic screwdriver if pos-sible.
Remove the burner, the diaphragm and the 2seals.
8666N178
5
6
7
8
3
2
1
9.5 Reassembling
Reassembly is the reverse procedure to disassembly.
- Connect the igniter electrode.
- Connect the ionisation sensor.
- Replace the anti-radiation plate.
- Replace the combustion chamber side and frontplates.
- Switch on and open the gas supply.
Check for gas leaks.
22
9.3 Replacing the diaphragm
9.4 Replacing the gas assembly modulator
8666N179
9.2 Replacing the injectors
7
8666N201
Replace the injectors and the seals (see chapter 7). When replacing the burner, fit the new diaphragm to thegas assembly between 2 new seals. See chapter 7.
8666N184
Disconnect the two wires from the modulator.
Unscrew the 2 screws retaining the modulator using a Torx No. 20 wrench.
Replace the modulator and the seal, checking that the seal and the spacer seat correctly.
� Modulator with grey cap = natural gas, modulator mark:1.5 - 20 mbar.
� Modulator with yellow cap = butane/propane, modulator mark: 3 - 37 mbar.
Reconnect the 2 wires to the modulator.
2
3
1
23
17
8666N104 A
9.6 Adjusting the minimum pressure
Natural gas H and L, butane and propane.
Adjust the pressure at the burner downstream of thegas assembly. The values to set are indicated inchapter 7. Measure the pressure at the boiler by connecting apressure gauge to pressure offtake 17, as follows:
9.7 “Gas type” label
Affix the label indicating the type of gas for which theboiler is equipped and set up.
1
3
2
5
8666N122
Remove the screw retaining the plastic cover.
Remove the cover.
Verify that the “maximum flowrate” plastic nut isscrewed fully home.
Force operation of the boiler at the minimum out-put setting by pressing the “clean” button E andholding it down for 5 seconds (see section 4).
Adjust the minimum pressure with the brass nut.- Turning the nut clockwise increases the
pressure.- Turning the nut anti-clockwise
reduces the pressure.
After completing the adjustment, replace thecap.
To revert to normal operation, press button E briefly.
1
2
3
4
5
Disconnect the pressure gauge.Screw in the screw of the pressure off-take. Check for gas leaks.
8666N183
6
24
10. MAINTENANCE
4
4
6
30
5
5
3
8666N119 A
10.1 Main heat exchanger
Periodically check the main heat exchanger for soi-ling.If necessary remove the heat exchanger and wash itwith very hot water containing a detergent.
Maintenance operations must be carried out by aqualified professional.
10.2 Burner
Check the condition of the burner annually.Use a dry soft brush to clean the burner, or wash itwith hot water containing a detergent. Rinse tho-roughly.
For instructions on removing the burner, see section9.1.
1
2
8666N176
Remove the boiler casing front panel (2 screwsat the top).
Remove the front plate from the combustionchamber (2 screws at the top + 2 wing nuts).
Remove the anti-radiation plate.
Remove the side plates of the combustionchamber.
Unscrew the 3/4" nuts of the heat exchanger(30 mm wrench).
Remove the main heat exchanger by pulling ittowards you.
2
3
4
1
5
6
Disconnect the electrical output supplyand the gas supply from the boiler. Closethe boiler isolating valves and open thedrain screws.
Note:When refitting the main exchanger:- grease the threads of the connectors- replace the seals- tighten the nuts moderately
25
1
37
4 6
5
If the domestic hot water heat exchanger is affectedby limescale, clean it by connecting a descaling
pump to the two domestic water connectors ➂.Use only products suitable for this purpose.
To obtain access to the domestic water connectors:
Tilt the control panel forward after removing the2 fixing screws at the sides.
Unscrew the two 1/2”nuts on the domestic waterheat exchanger (24 mm wrench).
Unscrew slightly the 3/4” nut on the domestichot water outlet (30 mm wrench).
Pivot the domestic hot water outlet tube towardsthe front.
Unscrew the 3/4" nut on the domestic cold waterinlet pipe (30 mm wrench).
Remove the domestic cold water inlet pipe.
Connect the descaling device to the two 1/2"exchanger connectors.
After descaling, reassembly is the reverse of theabove procedure.Replace the seals with new seals.
10.3 Domestic hot water
Protect the control panel from beingsplashed with descaling product.
8666N182
1
2
3
4
5
6
7
8
Disconnect the electrical output supplyand the gas supply from the boiler.Close the domestic water inlet and outletvalves and open the drain screws.
Turn the tap off (6mm spanner) to avoid any dra-wing off from the domestic circuit (kitchen,bathroom, etc.) and major discharge when thefilter is dismantled.
Unscrew the drain cock after connecting a hose(dimension: 8 mm).
Unscrew the adjustment door-filter-tap with a17mm spanner.
If required, remove the filter and clean it with asoft brush- replace the filter on the filter-door and screw itinto the tap (17mm spanner)- turn off the drain cock- turn on the tap (6mm spanner).
1
3
2
4
8666N293
1
2
3
4
10.4 Cleaning the ”cold water” filter(CITY 2.24 only)
26
11. DRAINING DOWN
To drain down the boiler:
- Close gas valve 3, water valves 1, 2, 5(8 mm wrench) and 4 (6 mm wrench).
- Connect an 8 mm internal diameter hose to drain screw 6.
- Unscrew the drain screw.
6
4*6*
6*
3
5
2*1
6
8666N117 B
* Boiler prepared for domestic hot water supply.
27
AL
IO
utpu
t su
pply
CD
CC
omm
unic
atin
g re
mot
e co
ntro
ller
DB
MF
low
rate
det
ecto
rE
XT
Ext
erna
lJ.
.P
rinte
d ci
rcui
t co
nnec
tor
MN
MP
ress
ure
gaug
eP
Pum
p
SB
Tank
sen
sor
SC
HB
oile
r se
nsor
SE
CS
Dom
estic
hot
wat
er s
enso
rS
EC
SM
Dom
estic
hot
wat
er m
aint
ain
tem
p. s
enso
rS
IIo
nisa
tion
sens
orTA
Igni
ter
tran
sfor
mer
TAF
Ant
i-bac
kflo
w t
herm
osta
t
TAM
Roo
m t
herm
osta
tT
EM
PO
Tim
e-de
lay
adju
stm
ent
TS
Saf
ety
ther
mos
tat
VG
MM
odul
atin
g ga
s va
lve
VIN
VIn
vert
er v
alve
CIT
Y2.
24 w
ith
flu
e lin
er88
06-5
112
M
8806
-511
1
1014
1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
J12
J17
2
J4
VIN
VP
VG
M
TE
MP
O
11
11
23
22 L
NA
LI.
230V
/ 50
Hz
J3J2
J18
J1 J2
J6 J8 J10
J7 J8
J1
J11
12
34
56
2
θ °C
θ °C
θ °C
θ °C
2
SC
H
SE
CS
SE
CS
M
PM
NM
TAF
1 1
2 1
2 1
2 1
θ
DB
M
TS
1 2 3
1 2 3 1 2
12
56
34
3 4 5 6
J3J4
J5
SI
TA
12
34
56
CD
CTA
MS
B
J5
J15
J13
8666
N11
0 E
base
d on
8666
.407
4 C
12. ELECTRICAL CIRCUIT DIAGRAMS
28
AL
IO
utpu
t su
pply
CD
CC
omm
unic
atin
g re
mot
e co
ntro
ller
DB
MF
low
rate
det
ecto
rE
XT
Ext
erna
lJ.
.P
rinte
d ci
rcui
t co
nnec
tor
MN
MP
ress
ure
gaug
eP
Pum
p
SB
Tank
sen
sor
SC
HB
oile
r se
nsor
SE
CS
Dom
estic
hot
wat
er s
enso
rS
EC
SM
Dom
estic
hot
wat
er m
aint
ain
tem
p. s
enso
rS
IIo
nisa
tion
sens
orTA
Igni
ter
tran
sfor
mer
TAF
Ant
i-bac
kflo
w t
herm
osta
t
TAM
Roo
m t
herm
osta
tT
EM
PO
Tim
e-de
lay
adju
stm
ent
TS
Saf
ety
ther
mos
tat
VG
MM
odul
atin
g ga
s va
lve
VIN
VIn
vert
er v
alve
CIT
Y1.
24 w
ith
flu
e lin
er
8806
-511
2
M
8806
-511
1
1014
1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
J12
J17
12
34
56
CD
CS
BJ5
2
J4
VIN
VP
TE
MP
O
11
11
23
22 L
NA
LI.
230V
/ 50
Hz
J3J2
J18
J1 J2
J6 J8 J10
J7 J8
J1
J11
12
34
56
2
θ °C
θ °C
SC
H
PM
NM
TAF
1
2 1
2 1
θT
S
1 2 3
1 2 3 1 2 3 4 5 6
J3J4
J5
SI
TAM
VG
M
12
56
34
TAV
GM
12
56
34
TA
J15
J13
8666
N10
9 E
base
d on
8666
.407
8 C
29
Alarm code MeaningCentral heating outlet temperature sensor fault
Anti-overflow sensor fault
Domestic hot water outlet (CITY 2.24) storage tank (CITY 1.24) sensor fault
Domestic hot water maintain temperature function sensor fault
Storage tank sensor connection on CITY 2.24 (incoherent)
Electronic pressure gauge fault
2. SENSOR alarms
ouou
ou
13. FAULT CODES
In the event of a fault, the display indicates an alarm
message by alternately showing and a codefrom which the type of fault can be determined.
There are two alarm categories:
1. Safety alarms
Alarm code MeaningIgniter fault
Ionisation fault
Spurious flame
Overheating alarm
No water
Combustion product overflow. Display shows combustion product temperature at time of overflow
Card fault
Safety fault display interrupted
à
14. LIST OF SPARESSee following pages
8666N121
8666N121
Spares CITY 1.24 and 2.24
8666-4140 A
DE DIETRICH THERMIQUE • BP 30 • 57, rue de la Gare • F-67580 MERTZWILLER • Tél. : +33 3 88 80 27 00 • Fax : +33 3 88 80 27 99N° IRC : 347 555 559 RCS STRASBOURG
Spare Part Centre • 4, rue d'Oberbronn • F-67110 REICHSHOFFEN • Tel. :+33 3 88 80 26 50 • Fax : +33 3 88 80 26 98
1235
4
6
7
Note: to order a spare part it is essential to give the code number in the list opposite the item number of the part required.
8
11
13
9
66
1214
10
11
8666N133
8666N134
FRAME
ANTI-BACKFLOW DEVICE + COMBUSTION CHAMBER
15
16
18
1719A
25A
26
25
26
19
20
21
16
17
26
19
23
24
22
25A
26
2519A
PIPES – 1 SERVICE
PIPES – 2 SERVICES
8666N135B
8666N136 B
CITY 1.24 and 2.24
2/7
36
38a
39 / 40
38
92
93
91
30 / 31
42
64 65
41
34 / 35
14x
33
32
37
4x
2x
52 63 67
54
47
46
49
45
48
51
50
46
65
57
55 60
61
59
56
6268
- Fermer les vannes départ et entrée eau froi-
de sanitaire .
- raccordé un tuyau flexible ø intérieur 8 mm sur les visde vidange , puis les desserrer.
Couper l'alimentation électrique et l'ali-
mentation en gaz de la chaudière .
03/99 - 948.58.118 - 8666-4106
Kit régulateur de débit d'eau sanitaire
Colis HA 218
CITY 2.24 ET 2.24 FF
Pour monter un régulateur de débit 8 l/mn ou 10 l/mn surune chaudière CITY 2.24 ou 2.24 FF, procéder commesuit :
46
6
32
8666N192
4
6
3
8666N191
2
Blanc : 8 l/mn Bleu : 10 l/mn
69
Montage
Assembly
DOMESTIC HOTWATER HEAT EXCHAN-GER AND 3-WAYVALVE ASSEMBLY
8666N137A
8666N138 C
BURNER
CITY 1.24 and 2.24
From14/01/99
Until13/01/99
3/7
70
71
73
101
102
72
81
83
76
85
77
75
78
87
88
86
79 80
82
BOILER CASING
CONTROL PANEL
8666N140
8666N139
CITY 1.24 and 2.24
4/7
112
113
106
122
129
124
126
110
105
109
108
111
107
108
128
114
116
122
118
117
123
125 121119 121a 120
115
127
124
128
126
BRACKET - 1 SERVICE
BRACKET – 2 SERVICES
8666N141C
8666N142 A
CITY 1.24 and 2.24
5/7
CITY 1.24 and 2.24
FRAME
1 8666-8500 COMPLETE (CPL) FRAME
2 8666-5500 COMPLETE LEFT UPRIGHT
3 8666-5501 COMPLETE RIGHT UPRIGHT
4 8666-5502 COMPLETE CHASSIS SUPPORT
5 8666-5503 COMPLETE TANK SUPPORT
6 8666-5504 COMPLETE PIPE SUPPORT
7 8666-5505 COMPLETE CABLE-CLAMP
ANTI-BACKFLOW DEVICE
8 8666-5569 COMPLETE ANTI-BACKFLOW DEVICE
9 8666-5506 COMPLETE NOZZLE
COMBUSTION CHAMBER
10 8666-5507 COMPLETE COMBUSTION CHAMBER BACK
11 8666-8544 INSULATED COMBUSTION CHAMBER SIDE PLATE
12 8666-8545 INSULATED COMBUSTION CHAMBER FRONT PLATE
13 8666-5508 COMBUSTION CHAMBER INSULATION KIT
14 8666-5509 FRONT PLATE FIXING ROD KIT
PIPES
1 SERVICE
15 8666-5510 COMPLETE CENTRAL HEATING OUTLET PIPE
16 8666-5511 COMPLETE PRIMARY RETURN PIPE
17 8666-5512 CPL CENTRAL HEATING EXCHANGER RETURN PIPE
18 8666-5513 CPL DOMESTIC HOT WATER PRIMARY RETURN PIPE
19 8666-5514 COMPLETE EXPANSION TANK PIPE
19a 8666-5578 COMPLETE EXPANSION TANK PIPE
25 9758-1257 8 LITRE EXPANSION TANK
25a 8666-5579 COMPLETE EXPANSION TANK
2 SERVICES
16 8666-5511 COMPLETE PRIMARY RETURN PIPE
17 8666-5512 CPL CENTRAL HEATING EXCHANGER RETURN PIPE
19 8666-5514 COMPLETE EXPANSION TANK PIPE
19a 8666-5578 COMPLETE EXPANSION TANK PIPE
20 8666-5515 COMPLETE PRIMARY OUTLET PIPE
21 8666-5516 CPL CENTRAL HEATING EXCHANGER OUTLET PIPE
22 8666-5517 COMPLETE LOOP TUBE
23 8666-5518 COMPLETE DOMESTIC COLD WATER PIPE
24 8666-5519 COMPLETE DOMESTIC HOT WATER PIPE
25 9758-1257 8 LITRE EXPANSION TANK
25a 8666-5579 COMPLETE EXPANSION TANK
26 9491-8141 AUTOMATIC AIR BLEEDER + SEAL
BURNER
30 9758-0051 WORGAS NG BURNER
31 9758-0052 WORGAS BP BURNER
32 8666-5520 COMPLETE IGNITER SPARK PLUG SET
33 8666-5521 COMPLETE IONISATION SENSOR
CONVERSION KIT
34 8666-7212 NG CONVERSION KIT
35 8666-7213 BP CONVERSION KIT
GAS VALVE
36 8666-5522 COMPLETE NG VALVE
36 8666-5580 COMPLETE B/P VALVE
37 8666-5523 COMPLETE GAS PIPE
38 8666-5524 COMPLETE VALVE GAS/MANIFOLD PIPE
38a 8666-5581 COMPLETE FLANGE
39 8666-5525 COMPLETE NG DIAPHRAGM
40 8666-5526 COMPLETE BP DIAPHRAGM
41 8666-8019 ANTI-RADIATION PLATE
42 8666-5577 COMPLETE CENTRAL HEATING EXCHANGER
2 SERVICES ONLY
45 8666-5527 COMPLETE DOMESTIC HOT WATER EXCHANGER
46 9490-2000 DRAIN VALVE
47 9491-8134 BLEED SCREW
48 9491-4277 NON-RETURN VALVE
49 8666-5528 DOMESTIC HOT WATER EXCHANGER FIXING KIT
50 8666-5529 CPL DOMESTIC HOT WATER EXCHANGER BASE
51 8666-5530 DOMESTIC HOT WATER EXCHANGER INSULATING KIT
52 8666-5531 DRAIN PIPE
COMPLETE 3-WAY VALVE
54 9513-2296 COMPLETE CIRCULATOR
55 9510-0502 COMPLETE STEPPER MOTOR
56 8666-5541 COMPLETE CIRCULATOR BASE
57 8666-5576 CIRCULATOR SEAL SUB-ASSEMBLY
59 8666-5571 COMPLETE VALVE BODY
60 9750-9052 COMPLETE VALVE
61 8666-5532 COMPLETE 3-WAY VALVE FLANGE
CONTROL AND SAFETY SYSTEM
62 9536-5107 ELECTRONIC PRESSURE GAUGE
63 8666-5533 COMPLETE SAFETY VALVE
64 8666-5534 COMPLETE SAFETY THERMOSTAT
65 9536-2442 SCREW-IN TEMPERATURE SENSOR
Ref. Code No. DESCRIPTION Ref. Code No. DESCRIPTION
6/7
CITY 1.24 and 2.24
66 9536-2443 FUMES SENSOR
2 SERVICES ONLY
67 8666-5535 COMPLETE FLOWRATE DETECTOR
68 9536-2440 CLIP-ON DOMESTIC HOT WATER OUTLET SENSOR
69 8666-7218KIT DOMESTIC HOT WATER FLOW RATE
CONTROLLER (10 L/MN)
BOILER CASING
70 8666-8540 CASING ASSEMBLY FLUE-LINER
71 8666-8549 COMPLETE LEFT SIDE PANEL
72 8666-8550 COMPLETE RIGHT SIDE PANEL
73 8666-8551 FRONT PANEL ASSEMBLY FLUE LINER
8666-5536 BOILER SCREW FASTENERS PACK
CONTROL PANEL
75 8666-8564 COMPLETE 1.24 NG CONTROL PANEL HO
75 8666-8565 COMPLETE 1.24 B/P CONTROL PANEL HO
75 8666-8566 COMPLETE 2.24 NG CONTROL PANEL HO
75 8666-8567 COMPLETE 2.24 B/P CONTROL PANEL HO
76 9752-5362 PRE-ASSEMBLED PANEL
77 9655-9151 FRONT PANEL PLATE
78 8666-5544 COMPLETE CARD SUPPORT
79 8666-5545 COMPLETE REAR COVER
80 9752-5312 CONNECTOR COVER
81 8666-5546 COMPLETE PRE-ASSEMBLED FLAP
82 9655-9150 FLAP PLATE
83 8666-5547 CONTROL BUTTON KIT
8666-5548 PANEL ACCESSORY KIT
85 8806-5512 COMPLETE DISPLAY CARD
86 8806-5511 CPL WALL-MOUNT CENTRAL UNIT CARD
87 8666-5549 COMPLETE CHEM SAFETY CARD
88 9654-7000 4 A FUSE
91 8666-5582 COMPLETE ANSTOSS IGNITER
92 8666-5583 COMPLETE IGNITER SUPPORT
93 8666-5584 COMPLETE IGNITER COVER
8666-4926 ASSEMBLED 2-PIN CONNECTOR
WIRING HARNESSES
8666-4922 MAIN SUPPLY CABLE
8666-4923 PUMP CABLE
8666-4925 IONISATION SENSOR CABLE
8666-4924 UC-CS BUS CONNECTION CABLE
8666-4929 EARTH WIRE
8666-4930 2.24 BASIC HARNESS CH.HO
8666-4932 1.24 BASIC HARNESS CH.HO
8666-4934 HONEYWELL CABLE CONNECTOR
BACKPLATE
101 8666-1517 ASSEMBLE BACKPLATE
102 8666-0543 BACKPLATE HEIGHT EXTENSION
1 SERVICE
105 8666-8506 COMPLETE 1.24 CONNECTOR PANEL
106 8666-5551 UNEQUIPPED CONNECTOR PANEL PLUS FIXINGS
107 8666-5552 COMPLETE CENTRAL HEATING OUTLET VALVE
108 8666-5553 COMPLETE DOMESTIC HOT WATER OUTLET VALVE
109 8666-5554 COMPLETE GAS VALVE
110 8666-5555 CPL CENTRAL HEATING RETURN VALVE
111 8666-5558 COMPLETE BYPASS CONNECTING PIPE
112 8666-5562 161 MM CONNECTING PIPE KIT
113 8666-5575 231 MM CONNECTING PIPE KIT
114 8666-5574 COMPLETE FILLER TUBE
128 8666-5564 COMPLETE EVACUATION CONNECTOR
129 8666-5587 PIECES FOR CONNECTION
2 SERVICES
115 8666-8507 COMPLETE 2.24 CONNECTOR PANEL
116 8666-5551 UNEQUIPPED CONNECTOR PANEL PLUS FIXINGS
117 8666-5552 CPL CENTRAL HEATING OUTLET VALVE
118 8666-5553 CPL DOMESTIC HOT WATER OUTLET VALVE
119 8666-5554 COMPLETE GAS VALVE
120 8666-5555 COMPLETE CENTRAL HEATING RETURN VALVE
121 8666-5556 COMPLETE COLD WATER INLET VALVE
121a 8666-5570 D. C. W. ADJUSTER SCREW + VALVE FILTER
122 8666-5557 COMPLETE DISCONNECTOR
123 8666-5558 COMPLETE BYPASS CONNECTING PIPE
124 8666-5559 CPL DISCONNECTOR DOWNSTREAM CON. PIPE
125 8666-5560 CPL DISCONNECTOR UPSTREAM CONNECTOR PIPE
126 8666-5561 COMPLETE DISCONNECTOR FLOW PIPE
127 8666-5563 COMPLETE 2.24 CONNECTOR PIPE KIT
128 8666-5564 COMPLETE EVACUATION CONNECTOR
SUNDRY
8666-5565 PANEL SEAL PACK
8666-5566 BACKPLATE FIXINGS PACK
8666-5567 BOILER SEALS PACK
9731-0700 O-RING GREASE
Ref. Code No. DESCRIPTION Ref. Code No. DESCRIPTION
11/007/7
37
Thank you for purchasing a DE DIETRICH appliance,and for the confidence in us that your purchasedemonstrates.
We would like to point out to you that the device willretain its original qualities only if it checked and main-tained regularly.
Your installer and the entire DE DIETRICH networkare naturally ready, willing and able to assist you.
Warranty conditions
Your device is warranted against all manufacturingdefects from the date of purchase for a period of 2years.
We shall not be liable as manufacturer in the event ofincorrect use of the device, lack of or insufficient main-tenance of the device or incorrect installation of thedevice (you are responsible for assuring that the boi-ler is installed by a professional installer). In particularwe shall not be liable for damage, losses or injuryconsequent upon installation that does not conform to:
- applicable laws and regulations,- specific requirements relating to the installation,- our manuals and instructions.
Our warranty is limited to exchange or repair of partsagreed to be defective by our technical departmentand excludes labour, travel and transportation costs.
Our warranty does not cover replacement or repair ofparts required because of normal wear and tear, incor-rect use, work carried out by unqualified third parties,lack of or insufficient supervision or maintenance,non-standard electrical output supply and use of inap-propriate or poor quality fuel.The warranty covers sub-assemblies such as motors,pumps, solenoid valves, etc. only if they have neverbeen removed from the boiler.
15. WARRANTY
38
Notes
39
Notes