manual detector de metales

56

Click here to load reader

Upload: jau-joao-calvera

Post on 23-Dec-2015

125 views

Category:

Documents


14 download

DESCRIPTION

manual de detector de metales

TRANSCRIPT

Page 1: Manual Detector de Metales

UK

Operator Manual

Industrial Metal DetectorsTHS/21E - THS/21

w w w . c e i a . n e t

Page 2: Manual Detector de Metales

Document Date Hardware SoftwareFI002K0024v1000UK 11 / 05 / 2011 HV5.xx THSV53xx - ALMV52xx

REVISION HISTORYRev. Date Author Reference Description

1 11/05/2011 TP2 – Pasquini - First issue

WaRRaNTY TERmSThe warranty period on all CEIA products is 12 months from the date of delivery. The warranty applies to all products supplied by us. The warranty covers defects of all components excluding batteries. The warranty does not cover damage caused by improper or inappropriate use or use for purposes other than those described in this manual. Do not tamper with the device. Do not open the housing. Tampering with or opening the device will void the warranty.

Page 3: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

3FI002K0024v1000UK

UK

Operator Manual

Industrial Metal DetectorsTHS/21E - THS/21

Page 4: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

4 FI002K0024v1000UK

CONTENTSREVISION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Warranty terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 - SAFETY INSTRUCTIONS – WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1 .1 - Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1.1 - General warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1.2 - Use warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1.3 – Maintenance warnings. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1 .2 – Permitted and improper uses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2.1 – Permitted uses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2.2 – Improper uses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

1 .3 – Residual risks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 - DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2 .1 – General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.1.1 - Detection probes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.1.2 - Applicable power supply boxes . . . . . . . . . . . . . . . . . . . . . . 13

2.1.2.1 - Control Power Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.1.2.2 - Conveyor Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.1.2.3 - Field Generator (MAG). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2.1.3 - Integrated system with conveyor belt . . . . . . . . . . . . . . . . . . . 142 .2 – Sicurezze del dispositivo ed etichette di avvertenza . . . . . . . . . . . 16

3 - USE OF THE DEVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 .1 – Switching on the Metal Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3.1.1 - Signals at power-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173.1.2 – Signals given during normal operation. . . . . . . . . . . . . . . . . . 19

3.1.2.1 - Indication of the received signal . . . . . . . . . . . . . . . . . . . . . . . . . 193.1.2.2 - Display messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

3.1.3 – Signals given during self-diagnosis. . . . . . . . . . . . . . . . . . . . 213 .2 - Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

3.2.1 – Optical indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223.2.1.1 - External beacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

3.2.2 – Acoustic indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 .3 – Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

3.3.1 – Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243.3.2 - Using the Quick Access key . . . . . . . . . . . . . . . . . . . . . . . . . 253.3.3 - Conveyor Control System control panel . . . . . . . . . . . . . . . . . . 26

Page 5: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

5FI002K0024v1000UK

3 .4 – Use of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273.4.1 – Sensitivity check with reference sample . . . . . . . . . . . . . . . . . 273.4.2 – Normal use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

3.4.2.1 - Starting/stopping the conveyor belt . . . . . . . . . . . . . . . . . . . . . . . 273.4.2.2 - Adjustment of the belt speed . . . . . . . . . . . . . . . . . . . . . . . . . . . 283.4.2.3 - Alarm reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.4.2.4 - Fault reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

3.4.3 - Removing and emptying the reject bin . . . . . . . . . . . . . . . . . . 303.4.3.1 - THS/FBB and THS/MBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.4.3.2 - THS/FB and THS/M65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.4.3.3 - THS/MBR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

3.4.4 – Automatic stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.4.4.1 - Emergency button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

3 .5 - Base functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.5.1 - Access to Programming mode . . . . . . . . . . . . . . . . . . . . . . . 33

3.5.1.1 - THS/xx21E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.5.1.2 - THS/xx21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

3.5.2 - Selection of a product . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383.5.2.1 - THS/xx21E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383.5.2.2 - THS/xx21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

3.5.3 – Sensitivity check with reference sample . . . . . . . . . . . . . . . . . 403.5.4 - Performing periodic tests . . . . . . . . . . . . . . . . . . . . . . . . . 40

3.5.4.1 - Test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413.5.5 - Quick test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

4 - MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454 .1 – Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454 .2 – Periodic Maintenance procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 46

4.2.1 – External cleaning instructions . . . . . . . . . . . . . . . . . . . . . . . 464.2.2 - Cleaning the parts in contact with the product. . . . . . . . . . . . . . 474.2.3 - Cleaning of the Conveyor belt . . . . . . . . . . . . . . . . . . . . . . . 48

4.2.3.1 - Ejection system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.2.3.2 - Belt disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

4 .3 - Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.3.1 - Self-resetting protections. . . . . . . . . . . . . . . . . . . . . . . . . . 524.3.2 – Troubleshooting table . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.3.3 - Self-diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Page 6: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

6 FI002K0024v1000UK

SYmBOLS

The equipment is marked with this symbol wherever the user should refer to this manual in order to avoid possible damage. The same symbol appears in the manual at points where warnings or particularly important instructions, essential for safe, correct operation of the device, are given.

The equipment is marked with this symbol in the areas where there is dangerous voltage. Only trained maintenance personnel should carry out work in these areas. The same symbol appears in the manual at points where warnings essential for safe, are given.

The equipment is marked with this symbol in the areas where the user must be careful to avoid crushing of hands. Only trained maintenance personnel should carry out work in these areas. The same symbol appears in the manual at points where essential safety warnings are given.

The equipment is marked with this symbol in the areas where the user must be careful to avoid coming into contact with moving components. Only trained maintenance personnel should carry out work in these areas. The same symbol appears in the manual at points where essential safety warnings are given.

The equipment is marked with this symbol wherever the user must not have access to potentially dangerous areas.

The equipment is marked with this symbol in the areas where the user must be careful to avoid crushing of feet. Only trained maintenance personnel should carry out work in these areas. The same symbol appears in the manual at points where essential safety warnings are given.

CEIA Metal Detectors employ low intensity electromagnetic fields in compliance with current legislation.MAGNETIC FIELDS can affect pacemakers. Wearers of pacemakers, cardiac defibrillators and other life supports must not operate in proximity of the inductor or the heating inductors of this device.Wearers of pacemakers must not use the Metal Detectors of the THS/MN21 series which use static electromagnetic fields. Wearers should consult their doctor for advice on avoiding this hazard.

LASER LIGHT: This symbol appears in this manual at those points where warnings or information relating to laser pointing devices are given. Such devices may be dangerous. It is therefore essential that the guidelines reported in this manual be followed.

This symbol appears in the manual at points where suggestions, additional information or other relevant notes are given.

Page 7: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

7FI002K0024v1000UK

1 - SaFETY INSTRUCTIONS – WaRNINGS

1.1 - Warnings

Read this manual carefully before installing, operating or carrying out maintenance on the device. Keep the manual in a safe place for future reference, and in perfect condition. This manual must accompany the device described therein in the case of change of ownership, and until the device is broken up.

The functions accessible to users and behaviour of the system, may differ from what described in this manual, according to the settings made. Contact the system administrator for any questions.

1.1.1 - General warnings

• This equipment complies with the directive 2004/108/EC for industrial applications.• All personnel operating with or performing operations on the device must have an

adequate preparation and shall know the procedures described in this manual.• Follow the instructions contained in this manual for all operations relating to installation,

use and maintenance of the device. CEIA cannot be held responsible for any damage resulting from procedures which are not expressly indicated in this manual, or from any lack of attention, either partial or total, of the procedures described therein.

• This manual must accompany the device described therein in the case of change of ownership, and until the device is broken up.

Page 8: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

8 FI002K0024v1000UK

1.1.2 - Use warnings

CEIA Metal Detectors employ low intensity electromagnetic fields in compliance with current legislation.MAGNETIC FIELDS can affect pacemakers. Wearers of pacemakers, cardiac defibrillators and other life supports must not operate in proximity of the inductor or the heating inductors of this device.Wearers of pacemakers must not use the Metal Detectors of the THS/MN21 series which use static electromagnetic fields. Wearers should consult their doctor for advice on avoiding this hazard.

• If the device is stored for a long period in temperatures outside the operating range, wait for the temperature of the detector to come back within that range before switching on.

• Do not supply the device when the Power Supply Box is open. Do not open during use.• Trapping and drawing in hazard. Do not place body parts, clothing or dangling objects

close to the device. Do not wear loose fitting clothing which might become trapped in the machine. If you have long hair, wear a hair net.

• During use do not insert body parts or objects inside the material transit tunnel.• Do not obstruct product transit.• When the machine is operating, only use the control panels and the emergency stop

buttons to control the machine.• Before you start the conveyor belt, check that the reject bin and its cover are present and

correctly positioned.• Before you make any changes to the machine configuration, switch off the machine.

Changes to machine configuration may only be made by authorized personnel who have control of the work area.

• Whenever there is any suggestion that the level of protection has been reduced, the device should be taken out of service and secured against any possibility of unintentional use, and authorised service technicians should be called. The level of protection is considered to have been reduced when:-- the-device-shows-visible-signs-of-wear-and-tear,-especially-on-parts-that-ensure-the-device-protections--(boxes,-gaskets,-glands,-fixing-screws,-etc.);

-- the-power-supply-box-is-not-correctly-closed;-- the-earth/ground-connections-are-not-compliant;-- the- device- has- suffered- mechanical- or- electrical- damage- (knocks,- shocks,- bumps,-etc..);

-- the-device-does-not-operate-correctly-or-as-specified-in-this-manual;-- the-device-has-been-stored-for-long-periods-in-sub-optimal-conditions;--- the-device-has-suffered-severe-stress-during-transport;--- the-device-has-come-into-contact-with-corrosive-substances.

• Do not supply the device when the Power Supply Box is open. Do not open during use.

Page 9: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

9FI002K0024v1000UK

1.1.3 – Maintenance warnings

• During all maintenance operations ensure the complete absence of any potentially explosive atmosphere.

• Perform all maintenance operations following the procedures described in the Maintenance section of this manual.

• Before you move the machine or start maintenance or cleaning, switch off and lock out the power supply and the compressed air supply.

• Clean the various parts of the system following the procedures defined by the customer. Cleaning procedures should also comply with the hygiene requirements for the process and the working environment and must also take into account the degree of protection of the equipment.

• Read the chapter on Maintenance carefully before calling the service centre.• Whatever the problem, only specialised service personnel authorised to work with CEIA

equipment should be called.• Before you restart the machine, check that all the guards are present and efficient.

Check that the drive components and the electrical and pneumatic systems are efficient.

Page 10: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

10 FI002K0024v1000UK

1.2 – Permitted and improper uses

1.2.1 – Permitted uses

• The THS/21E and THS/21 electronic Metal Detectors are designed for the detection of magnetic and non-magnetic metal masses transiting inside the detection probe.

• Handle the device with care and without excessive force during installation, use and maintenance

• The final user is responsible for selecting the appropriate sensitivity for their application. After this selection has been made, and programming has been adjusted accordingly, it is also the final user's responsibility to check calibration using the test object(s) appropriate to the level of security selected. Calibration testing must also be performed at regular intervals to ensure the continued efficiency of the equipment.

1.2.2 – Improper uses

• The THS/21E and THS/21 Metal Detectors are not suitable for installation or use in explosive or potentially explosive atmospheres.

• Any maintenance or repair of the device while open and powered up should be avoided, and in any case should only be carried out by trained personnel who are fully aware of the risks which the operation entails.

• Electric arc welding must not be carried out on the detector probe, on the control power box or on any part of the attached structure.

• The device is fitted with mechanical and electronic protections, described in this manual. Removing or reducing these protections is forbidden.

• The machine is not designed for use in hazardous environments where there is a risk to the health and safety of the operator.

• We recommend that you do not use the equipment in very dry environments. Very dry environments can generate electrostatic charges.

Page 11: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

11FI002K0024v1000UK

1.3 – Residual risks• Empty the reject material bin at regular intervals. Exercise caution when emptying the bin because it

could be heavy or contain very hot material. Define and implement a procedure for this operation. We decline all liability for injury to persons or damage to property caused by incorrect emptying of the reject material bin.

• Trapping and drawing in hazard. Body parts or loose dangling clothing can become trapped in the moving parts of the machine. Only authorised operators wearing suitably close-fitting overalls are permitted to work in this area.

• Tripping and slipping hazard. The absence of a reject material bin or a system for collecting ejected product can cause material to be deposited on the floor thereby creating a tripping and slipping hazard.

• Injury hazard to eyes, ears and sensitive body parts. When operating the machine do not approach the depressurising pipe of the blower ejector.

• Hard knocks to parts of the compressed air system can cause damage leading to leaks, bursting or the escape of compressed air.

• The machine is not fitted with a safety valve which depressurises the compressed air system in the event of a power failure which causes the lighting to fail. Automatic ejection systems (pusher cylinder or air jet types) will be powered down in the event of a power failure.

• The drive motor of the conveyor belt is covered by a metal guard except on the lower side and on the side facing the inside of the machine. Burns hazard: guard surfaces are very hot.

• Burns hazard. Caution hot surfaces. If the weight carried on the belt exceeds the limits specified in the technical data this will cause the motor to overheat. If dirt residues are not cleaned from the machine at regular intervals this also will cause the motor to overheat.

• Although the power of the laser beam used in barcode readers is very low, it can be dangerous to the human eye if stared into for long periods of time.

• Failure to follow the operating instructions in this manual may cause a loss of food characteristics. • On equipment where the material to be inspected is loaded and unloaded manually, it is the customer’s

responsibility to assess the risks to operator health and safety.• On integrated systems with the downstream conveyor connected up, the belt may start and stop

unexpectedly because it is controlled from this infeed line.

Page 12: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

12 FI002K0024v1000UK

2 - dESCRIpTION

2.1 – General description

2.1.1 - Detection probes

THS/21E, THS/21E-3F, THS/SL21E, THS/SL21E-3F

THS/21, THS/MS21, THS/SL21, THS/SLMS21

THS/G21E THS/G21, THS/GMS21

THS/MN21

A Metal Detector probe, complete with electronic control unit.B Power supply box, for connecting the device to mains power and to the external units (photocell,

ejector, etc.).C Connecting cable.D Tunnel.E Stainless steel control panel fitted with display and a programming keyboard.F Field generator.

Page 13: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

13FI002K0024v1000UK

2.1.2 - Applicable power supply boxes

Control Power Box Control Power Box with Remote Control Unit RCU

(21E series)

Control Power Box with Remote Control Unit RCU

(21 Series)

Small SizePower Supply Unit for

OEM applications(AL_card)

Conveyor Control System Field Generator (MAG)

2.1.2.1 - Control Power BoxThe Control Power Box contains the Metal Detector power supply unit. It has connections for external sensors and slave devices and can also house the remote control unit RCU.

2.1.2.2 - Conveyor Control SystemThis unit has the same functions as the full version of the Control Power Box and in addition has a conveyor belt motor driver/control section.

2.1.2.3 - Field Generator (MAG)This unit is part of the THS/MN21 model and is an additional power supply unit. It is not available for other models.

Page 14: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

14 FI002K0024v1000UK

2.1.3 - Integrated system with conveyor belt

A

B

H

L

C

G

F

M

D

E

THS/FBB, THS/MBB

A

B

H

L

C

G

F

M

D

THS/FB, THS/M65, THS/M69K

Page 15: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

15FI002K0024v1000UK

C

D

B

A

M H

L

F

G

THS/MBR

A Metal Detector antenna.B Programming and control panel.C Main switch.D Conveyor belt control panel.E Synchronization photocell.F External beacon.G Auxiliary emergency button.H Reject material bin.L Ejection system.M Support feet (to be fixed to the floor) or lockable castors.

Page 16: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

16 FI002K0024v1000UK

2.2 – Sicurezze del dispositivo ed etichette di avvertenzaThe THS/21 Metal Detector is fitted with a list of safety features described below, in order to warrant the proper protection level, during the correct use.

IP Protection degreeAll the system containers (probe and supply box) have a degree of protection (see the technical specifications) which ensure water tightness during operations and cleaning.All additional conveyor components have a protection degree of at least IP65. This also means that they are watertight.

Cable glandsThe cable glands installed on the system are IP68 and they are dimensioned for M16, M20 and M25 cables.In order to maintain the protection degree, you must use cables with characteristics and diameter compliant with the device glands and following the guidelines specified in this manual. Insert only one cable for each gland and take care that all of them are mounted and tightened in the correct way. Do not remove the caps from unused glands.

Self-diagnosis systemAn internal self-diagnosis system continuously monitors Metal Detector functional efficiency. In the event of a fault, a message is shown on the control display and all alarm indicators are activated together with corresponding relays.

PasswordThe access to Metal Detector parameters is protected by a six level password system.

Page 17: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

17FI002K0024v1000UK

3 - USE OF THE dEVICE

Before starting to use the device, carefully read the Safety instructions – Warnings section of this manual.

3.1 – Switching on the Metal Detector

Do not start a system whose safety systems are not fully efficient.Do not tamper with safety devices. The manufacturer declines all liability for damage resulting from tampering with safety features.

On the Conveyor Control System model, the ON/OFF switch is located on the power supply unit cover. On the Control Power Box, the external switch must be operated.

Conveyor-Control-System

3.1.1 - Signals at power-up

Control Panel Conveyor Control System

The presence of mains power supply is signalled by the lighting up of the indicator located on the control panel. On the Conveyor Control System this is also indicated by a warning light on the door of the box.

Page 18: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

18 FI002K0024v1000UK

When the device is turned on, the display lights up, as do the indicators located on the front of the electronics unit.The display shows, in sequence, the serial number and the version of the software program that drives the power supply unit.On integrated systems, the display shows the message RESET EMERGENCY and waits for you to press the Emergency Reset key. After this the following display appears:

THS/xx21E

The first line identifies the model and the software version of the Metal Detector. The second line indicates the type of programming, specific to one product which may be chosen from among 250 stored sets.

THS/xx21E V5.xxx

Prod. PROD01

^

THS/xx21

The first line identifies the model. The second line identifies the software version of the Metal Detector. The last line indicates the type of programming, specific to one product which may be chosen from among 500 stored sets.

CEIA THS/21ALM V5.xxx THS V5.xxx

Product:PROD01

On models where there is a control panel on both the probe and the power supply unit (because the probe is installed in a position which is inaccessible to the operator), the electronics unit display is disabled (the message “Remote control ON” appears).

Page 19: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

19FI002K0024v1000UK

3.1.2 – Signals given during normal operation

3.1.2.1 - Indication of the received signal On the fourth line of the display the signal being received is displayed by a horizontal illuminating bar, divided into sections. When the signal increases, the bar extends towards the right. The alarm threshold corresponds to the centre of the bar: the sections on the left are vertical bars, those on the right fill a white area.

THS/xx21E THS/xx21

Signal well below the threshold level

THS/xx21E V5.xxx

Prod. PROD01

^

CEIA THS/21ALM V5.xxx THS V5.xxx

Product:PROD01

Signal just below the threshold level

THS/xx21E V5.xxx

Prod. PROD01

^^^^^^^^^^

CEIA THS/21ALM V5.xxx THS V5.xxx

Product:PROD01

Signal above the threshold level (alarm)

THS/xx21E V5.xxx

Prod. PROD01

^^^^^^^^^^***

CEIA THS/21ALM V5.xxx THS V5.xxx

Product:PROD01

After the alarm, the maximum signal is displayed for a few seconds together with its amplitude

THS/xx21E V5.xxx

Prod. PROD01

A: 0.3dB

^^^^

CEIA THS/21ALM V5.xxx THS V5.xxx

A=8.5dB

Product:PROD01

Page 20: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

20 FI002K0024v1000UK

3.1.2.2 - Display messagesThe Metal Detector display shows messages relating to its current mode of operation:

THS/xx21E THS/xx21

The Metal Detector is in normal operating mode

THS/xx21E V5.xxx

Prod. PROD01

^

CEIA THS/21ALM V5.xxx THS V5.xxx

Product:PROD01

It will detect metals and activate connected slave devices.

The Metal Detector is in normal operating mode

THS/xx21E V5.xxx

Prod. PROD01

^^^^^^^^^^***

CEIA THS/21ALM V5.xxx THS V5.xxx

Product:PROD01

It has just detected a metal object and has activated connected slave devices

Programming access step

Password

#_____

Password

#_____

The Metal Detector requests a password

The Metal Detector has been set to programming mode

Sensitivity 265@

Product selection

Sensitivity~~~~~~265@Product selection

Accessible parameters can be modified

The Metal Detector requests a functional test

TEST

Prod. PROD01

^

** TEST **

Product:PROD01

See “Periodic test management” section in this manual

The Metal Detector requires an intervention

RESET EMERGENCY

(press R button)

^^

RESET EMERGENCY (press R button)

Product:PROD01

Page 21: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

21FI002K0024v1000UK

THS/xx21E THS/xx21

Status display

====== STATUS =======

Sensitivity 265

TX program 0

Band HIGH

[\\\\\ STATUS \\\\\\]Sensitivity 265Detection mode 4FE diameter 0.80NFE diameter 1.00SS diameter 1.20Prd.alarms 10{|| & Scroll down ||}

Press the STATUS key from the normal screen, to obtain a list of information about device status. Use the arrow keys to scroll through the list. Press P to return to the standard screen.

3.1.3 – Signals given during self-diagnosis

The THS/21 Metal Detector has an embedded self-diagnosis system. The messages shown on the display are given in section 4.3.3.

Page 22: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

22 FI002K0024v1000UK

3.2 - Indicators

3.2.1 – Optical indicators

THS/xx21 THS/xx21E

A POWER: a green indicator indicates the presence of powerB ALARM: a red indicator indicates the detection of a metal fragment or a fault in the unitC Display for the visualization of the messages relating to use, programming and self-diagnosis of

the deviceE a green indicator indicates that the conveyor is running. Flashes to indicate that the belt has been

stopped by the FOLLOWING CONVEYOR input and is waiting to be restarted automatically (see parameter RE).

Page 23: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

23FI002K0024v1000UK

3.2.1.1 - External beaconThe external beacon has coloured light modules which light up to indicate the following states (the coloured light modules actually present depend on the beacon supplied):

Model-THS/ FBB FB MBB M65 MBR

a RED Fault present

b AMBER Detection alarm present

c BLUE Test request

d Buzzer External horn

Standard Optional / Accessory

If you dismantle the beacon modules, make sure that you refit them in the original order.

THS/FBB systems have a single red module which lights up to indicate an alarm or a fault.

Light Meaning Light indication

a RED No alarm or fault present Off

An emergency to be reset Slow flashing

Fault or alarm present Fast flashing

b AMBER No alarm present Off

Detection alarm present On fixed

Waiting for alarm reset Slow flashing

c BLUE No test request present Off

Test request present Slow flashing

3.2.2 – Acoustic indicators

Systems fitted with the Control Power Box and the Conveyor Control System have an acoustic warning device (buzzer or horn) which sounds when the detector detects metal fragments or sounds to indicate a fault or a request for operator intervention.

Page 24: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

24 FI002K0024v1000UK

3.3 – Controls

3.3.1 – Control Panel

The control panel keyboard is used to control the Metal Detector and set the device parameters. The control panel keys and their functions are shown below:

THS/xx21E and THS/xx21

Key Function

Access and exit from the programming step

Return from the submenus to the previous menu

Exit from the Metal Detector Status display

Metal Detector Status display

Scroll through a list of instructions

Select the parameters to be changed

Modification of the parameter values

Select a submenu from the main menu

Confirm data entries

Reset fault (not all types)

Only on THS/xx21

Key Function

Cancel the last character entered

Quick access to preset functions

Modification of the parameter values

Page 25: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

25FI002K0024v1000UK

3.3.2 - Using the Quick Access key

The System Administrator can program up to 10 functions, so that they are quickly accessible through the Quick Access key and the corresponding number.

Press the Quick Access key.The display will show the list of the first five functions, programmed by the System Administrator.

[\\ QUICK ACCESS \\\]0) Products1) Autolearn2) Sensitivity3)4) Reset & Scroll down{|||||||||||||||||||}

Press the 2 key to access, for example, to the function of Sensitivity modification. If needed by the called function, user name and / or password will be asked.

User

#_____

To see the other five programmed functions, for the keys from 5 to 9, scroll the screen pressing the arrow keys.The + character beside a function, indicates that it is a link to the corresponding menu.

[\\ QUICK ACCESS \\\] $ Scroll up5)+MD Test6) 7)+Print8)+I/O status9)+Counters{|||||||||||||||||||}

The list of Quick Access functions represented above is just an example. The list is programmable and provided, as standard, ready to be customized.

For the programming of the list of functions accessible via the Quick Access button, see the Programming manual.

Page 26: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

26 FI002K0024v1000UK

3.3.3 - Conveyor Control System control panel

On the power supply unit of the Conveyor Control System, the enclosure cover incorporates a motor control panel.

Key Function

Start the conveyor belt

Stop the conveyor belt

Manual forward

See the table belowIncrease speed

Manual reverseDecrease speed

Metal Detector reset

Emergency reset

The motor speed control keys, depending on UD and MM parameters, have different functions:

MM

OFF ON

UD

OFF No function Manual forward

No function Manual reverse

ON Increase speed Manual forward

Decrease speed Manual reverse

Set MM=OFF on systems with THS/MBB, THS/M65, THS/MBR or on systems where the conveyor direction of travel cannot be reversed.

The manual forward/reverse controls are only enabled when the belt is stopped.

The increase/decrease speed controls are enabled both when the belt is stopped and the belt is running.

Page 27: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

27FI002K0024v1000UK

3.4 – Use of the device

3.4.1 – Sensitivity check with reference sample

It is important to check the efficiency (sensitivity and ejection of material) of the Metal Detector at regular intervals. To do this, perform a sensitivity test with a reference sample. See section 3.5.3 for the procedure.

3.4.2 – Normal use

3.4.2.1 - Starting/stopping the conveyor beltWith the power supply on and with the motor stopped, check that the LED are ON or OFF as shown in the following table:

Indicator Status

Mains voltage ON

Motor running OFF

• Press the Start button to start the motor: check that it starts up, and that the “Motor on” indicator comes on.

• To stop the motor, press the Stop button , check that it stops, and that the “motor on” indicator goes off.

During programming of the Metal Detector, the Conveyor Control System keyboard is disabled. While the Conveyor Control System keys are being used, Metal Detector programming is disabled.

Page 28: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

28 FI002K0024v1000UK

3.4.2.2 - Adjustment of the belt speedThe motor speed control keys have different functions according to the value of parameter MM (see the Programming Manual).The speed of the conveyor belt can be adjusted by: -- programming-the-BS-parameter-on-the-Metal-Detector-- simply-pushing- the-keys- located-on- the-Conveyor-Control-System,- if- the-parameter-MM=OFF.

During programming of the Metal Detector, speed adjustment using the and keys is disabled. When the Conveyor Control System keys are being used, the Metal Detector programming is disabled.

The “Speed” reading indicates the speed set, and varies in real time when the and keys are pressed. Any variation in speed is stored to memory as a parameter specific to the current product type.

Minimum~speed~~~~~20@

Speed 40

Maximum speed 60

Page 29: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

29FI002K0024v1000UK

3.4.2.3 - Alarm resetIn case of an alarm due to metallic contamination, the contaminated product is ejected from the product conveyor according to the type of operation which has been selected:

• in operation with automatic ejection of the contaminated material, the belt is not stopped and the contaminated product is sent into a reject bin which should be emptied at regular intervals by the operator. In this case, the detector resets automatically.

• in operation where the conveyor belt is blocked, the belt is stopped and the contaminated product is positioned in the exit area of the Metal Detector for manual removal by the operator.

All material between the probe and the stop line must be removed.

A manual reset and restart of the belt is required. To reset an alarm manually:• Press key E on the front panel (if KAR=ON).• Activate the RESET input.• Enter the programming mode and select the Reset command.• Press the Detector Reset pushbutton (on the Conveyor Control System only)

3.4.2.4 - Fault resetFor faults which require a manual reset, trace and remove the cause of the fault and then:

• Press key E on the front panel (if KFR=ON).• Activate the RESET input.• Enter the programming mode and select the Reset command.• Press the yellow Reset pushbutton (only on Conveyor Control System and with KFR=ON

or RBO)

Page 30: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

30 FI002K0024v1000UK

3.4.3 - Removing and emptying the reject bin

The reject bin must be emptied at regular.

During this operation exercise extreme caution. The reject material bin could be heavy or could contain very hot material. You should define a procedure for this operation. The manufacturer declines all liability for injury to persons or damage to property caused by emptying the bin in an incorrect manner.

3.4.3.1 - THS/FBB and THS/MBB

Press the Stop Belt button.

Using the key provided, open the door of the reject bin.Empty the bin.After emptying, close the door of the reject bin and lock it in position with the key.

Check that all the safety devices are present and efficient. Check for other hazards. Start the belt by pressing the Start button.

Page 31: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

31FI002K0024v1000UK

3.4.3.2 - THS/FB and THS/M65

Press the Stop Belt button.

Using the key provided, release the reject bin. Turn the handle to release it. Remove the bin from its seat. Empty the bin.After emptying, slide the bin onto its guides. Lock it in position with the handle and the key.

Check that all the safety devices are present and efficient. Check for other hazards. Start the belt by pressing the Start button.

Page 32: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

32 FI002K0024v1000UK

3.4.3.3 - THS/MBR

Press the Stop Belt button.

Using the key provided, release the reject bin. Turn the handle to release it. Remove the bin from its seat. Empty the bin.After emptying, slide the bin onto its guides. Lock it in position with the handle and the key.

Check that all the safety devices are present and efficient. Check for other hazards. Start the belt by pressing the Start button.

Page 33: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

33FI002K0024v1000UK

3.4.4 – Automatic stop

This function is only available on the Conveyor Control System.

On systems fitted with a synchronising photocell, if nothing passes through the Metal Detector for the length of time set in the parameter ST (see Programming section), the conveyor belt will stop automatically.

3.4.4.1 - Emergency buttonAn extra emergency button is mounted on the conveyor belt. Use this to stop the unit in the event of an emergency or a malfunction.

If necessary, the main system switch can also be used for this purpose.

The alarm indicators are activated.

RESET EMERGENCY

(press R button)

^^

RESET EMERGENCY (press R button)

Product:PROD01

Trace and remove the cause of the emergency stop and then reset the system by pressing the Emergency Reset key.

3.5 - Base functionsFor all programming operations, modifications of installation parameters, local and remote control, see the Programming manual, shipped with the present manual.

3.5.1 - Access to Programming mode

To enter the Programming mode press the key .The Metal Detector can request, depending on Administrator's settings, to enter an user name and/or a password. Each kind of operator can access only to specific set of parameters, or menus.

Page 34: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

34 FI002K0024v1000UK

3.5.1.1 - THS/xx21E

Entering the usernameIn the following example, the way to digit the username “STEVEN” is shown.

Description Display

Press to enter Programming. The cursor blinks in

the position of the first character.

User

#_____

Press 8 times to cycle back the alphabet and select

the letter S as the first character. Press to confirm.

User

S#____

The cursor moves on and starts suggesting again the

last character entered. Press once to select the

letter T and press to confirm.

User

ST#___

Using the arrow key, cycle back the alphabet until

the letter E is shown. Press to confirm.

User

STE#__

Using the arrow key, cycle up the alphabet until

the letter V is shown. Press to confirm.

User

STEV#_

Using the arrow key, cycle up the alphabet until

the letter C is shown. Press to confirm.

User

STEVE#

Using the arrow key, cycle up the alphabet until

the letter N is shown.

Press to confirm the username.

User

STEVEN

Page 35: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

35FI002K0024v1000UK

Entering the password

Description Display

After the user name, the password is required.

As an example we will digit 000004.

Password

#_____

Push the arrow key to select the 0 as the first

character. Press to confirm.

Password

*#____

The cursor moves on and starts suggesting again the

last character entered. Continue to push until the

cursor reach the last character position.

Password

*****#

Press four times the arrow key to set the number

4 as the last character.

Press to confirm the password.

Password

******

IThe display will show an asterisk in the place of each character entered.

Page 36: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

36 FI002K0024v1000UK

3.5.1.2 - THS/xx21

Entering the username

Description Display

Press to enter Programming. The cursor blinks in

the position of the first character.

User

#_____

Press four times the key to cycle through the

letters and to set the S as the first character.

The cursor moves automatically on.

User

S#____

Press twice the key to set the T as the second

character.

User

ST#___

Press three times the key to set the E as the third

character.

User

STE#__

Press four times the key to set the V as the fourth

character.

User

STEV#_

Again three times the key to set the E as the fifth

character

User

STEVE#

Press three times the key to set the N as the last

character.

Press to confirm the username.

User

STEVEN

Page 37: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

37FI002K0024v1000UK

Entering the password

Description Display

After the user name, the password is required. As an

example we will digit 000004.

Password

#_____

Press to get for the number 0 as the first character.

The cursor moves on.

Password

*#____

Continue to push until the cursor reach the last

character position.

Password

*****#

Press once the key to set the number 4 as the last

character.

Press to confirm the password.

Password

******

The display will show an asterisk in the place of each character entered.

Page 38: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

38 FI002K0024v1000UK

3.5.2 - Selection of a product

To select a different product, from the list of products programmed by the Administrator or the Supervisor, perform the following steps:

3.5.2.1 - THS/xx21E

Description Display

Access the programming phase as Operator, pressing

. Digiti your username and password, if requested.

Select the menu Product selection.

Product selection *

Select the command Product to start the selection of

a new product.

Product DEFAULT*

Press . The display will show an alphabetical list of

all stored products.

====== Product ======

*DEFAULT

PROD01

PROD02

Use the arrow keys to scroll the list up and down.

====== Product ======

DEFAULT

PROD01

*PROD02

Press to confirm the new product.

Product PROD02*

Page 39: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

39FI002K0024v1000UK

3.5.2.2 - THS/xx21

Description Display

Access the programming phase as Operator, pressing

. Digiti your username and password, if requested.

Select the menu Product selection.

Product~selection~~~§

Select the command Product to start the selection of

a new product.

Product~~~~~~DEFAULT@

Press . The display will show an alphabetical list of

all stored products.

[\\\\\ Product \\\\\] @DEFAULT PROD01 PROD02 POW003 SUGAR{|||||||||||||||||||}Search: #_________

Use the arrow keys to scroll the list up and down.

[\\\\\ Product \\\\\] DEFAULT PROD01 @PROD02 POW003 SUGAR{|||||||||||||||||||}Search: #_________

Press to confirm the new product.

Product~~~~~~~PROD02@

Typing letters in the search field results in a product list

restricted to the names that match that string.

[\\\\\ Product \\\\\] @PROD01 PROD02

{|||||||||||||||||||}Search: PR#_______

Page 40: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

40 FI002K0024v1000UK

3.5.3 – Sensitivity check with reference sample

It is important to check at regular intervals that the Metal Detector is operating efficiently. This is done running a detection and ejection test using test reference samples. -- Depending- on- product- characteristics- and/or- internal- quality- procedures,- the-customers-can-use-samples-they-have-defined-themselves-or-request-specific-samples-from-CEIA.

-- The- tests- can- be- carried- out- at- any- time- deemed- necessary- (e.g.- at- the- shift-changeover)- and/or- pre-programmed.- In- the- latter- case,- the- Metal- Detector- will-automatically-request-the-test.

It is possible to test the detection capability of the Metal Detector by selecting the DEFAULT product mode and using one or more of the reference samples indicated in the Factory Acceptance test (FAT).

3.5.4 - Performing periodic tests

At the end of the Test period, a message requesting a test is displayed. At the same time the external blue lamp is activated (BLUE LAMP output) together with the Test relay (depending on the settings of TRM parameter).

** TEST **

Product:PROD01

The test can be started by the quality control operator or the quality control supervisor (depending on the access level).

The periodical test request, can be disabled only byt the Administrator or by the Head of Quality Control.

Page 41: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

41FI002K0024v1000UK

3.5.4.1 - Test procedureThe procedure below describes a test with a ferrous sample; the other two samples, made from non-ferrous metal and in stainless steel, follow the same procedure.For the double and the triple test (see TMD on Programming Manual), the tests will be requested one after the other.The execution of the tests and the final response will be recorded in the event log.

THS/xx21E THS/xx21

FE test -0.80 @

NFE test-1.00

SS test -1.20

FE~test~-0.80~~~~~~~@NFE test-1.00SS test -1.20

To perform the Metal Detector test (independently or in response to the automatic request), select MD Test > FE test and press E key.

=====================

WAIT

---------------------

[\\\\\\\\\\\\\\\\\\\] WAIT

{|||||||||||||||||||}

Wait a few seconds, before performing the sample transit

=====================

PASSE FE SAMPLE

---------------------

[\\\\\\\\\\\\\\\\\\\] PASSE FE SAMPLE

{|||||||||||||||||||}

Pass the requested sample, together with the pure product, through the probe within one minute.

=====================

TEST PASSED

---------------------

[\\\\\\\\\\\\\\\\\\\] TEST PASSED

{|||||||||||||||||||}

If the sample is correctly detected and ejected (through the Ejection Confirmation check), the test is successful.

FE test -0.80 OK

NFE test-1.00

SS test -1.20

FE~test~-0.80~~~~~OKNFE test-1.00SS test -1.20

Pressing any key, the display returns to the MD test menu, where the positive outcome is also shown.

Repeat the test with the non-ferrous and stainless steel samples.

Page 42: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

42 FI002K0024v1000UK

If the test is unsuccessful, one of the following messages will be seen:

Failed test for Sample not detected

THS/xx21E THS/xx21

=====================

TEST FE FAILED

NO SAMPLE DETECTED

---------------------

[\\\\\\\\\\\\\\\\\\\] TEST FE FAILED NO SAMPLE DETECTED

{|||||||||||||||||||}

If the sample is not detected it could be that the transit was performed in the 20 seconds immediately after the request, or the sample signal is lower than the alarm threshold.

FE test -0.80 NO(1)@

NFE test-1.00

SS test -1.20

1- NO SAMPLE DETECTED

FE~Test~-0.80~~NO(1)@NFE Test-1.00SS test -1.201- NO SAMPLE DETECTED

Pressing any key, the display returns to the MD test menu, where the negative outcome is also shown.

Failed test for Sample too big

THS/xx21E THS/xx21

=====================

TEST FE FAILED

SAMPLE TOO BIG

---------------------

[\\\\\\\\\\\\\\\\\\\] TEST FE FAILED SAMPLE TOO BIG

{|||||||||||||||||||}

The signal given by the sample is considered too high to perform a valid test, according to SAC settings (see Programming Manual).

FE test -0.80 NO(2)@

NFE test-1.00

SS test -1.20

2- SAMPLE TOO BIG

FE~Test~-0.80~~NO(2)@NFE Test-1.00SS test -1.202- SAMPLE TOO BIG

Pressing any key, the display returns to the MD test menu, where the negative outcome is also shown.

Page 43: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

43FI002K0024v1000UK

Failed test for Ejection not confirmed

THS/xx21E THS/xx21

=====================

TEST FE FAILED

EJECT.NOT CONFIRM

---------------------

[\\\\\\\\\\\\\\\\\\\] TEST FE FAILED EJECT.NOT CONFIRM

{|||||||||||||||||||}

If the sample is correctly detected, but there is not any confirmation of its ejection, the test is considered to be unsuccessful.

FE test -0.80 NO(3)@

NFE test-1.00

SS test -1.20

3- EJECT.NOT CONFIRM

FE~Test~-0.80~~NO(3)@NFE Test-1.00SS test -1.203- EJECT.NOT CONFIRM

Pressing any key, the display returns to the MD test menu, where the negative outcome is also shown.

Test aborted

THS/xx21E THS/xx21

=====================

TEST ABORTED

---------------------

FE~Test~-0.80~~NO(1)@NFE Test-1.00 [\\\\\\\\\\\\\\\\\\\]

TEST ABORTED

{|||||||||||||||||||}

If the self-diagnosis system detects a fault of any kind, the test procedure will be interrupted and the message shown here will be displayed.The test can also be interrupted by pressing P during the test.

In the event of an unsuccessful test, the fault condition “TEST FAILED” is activated as set in the FF parameter (see Programming Manual).In this case, one of the following actions is possible:- Reset the system and if necessary perform the test again (STM=OFF)- Perform the test again to proceed (STM=ON)See the STM parameter in the Programming Manual.

Page 44: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

44 FI002K0024v1000UK

3.5.5 - Quick test

You can run a single test without having to enter the programming mode. This is done by enabling the input IN_AUX1 (with for example a pushbutton). Select the test by selecting the QCKT parameter in the QA Configuration menu.When you activate the input, the display will show a message requesting the corresponding test. Run the test by passing the sample through the unit in the manual mode or use an automatic system driven by the AUX relay (activated for 3 seconds when IN_AUX1 is activated).The result of the test will be recorded as usual in the event log as a Quick Test.

Page 45: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

45FI002K0024v1000UK

4 - maINTENaNCE

Before starting any maintenance operation, carefully read the Safety instructions - Warnings section of this manual.

Any maintenance or repair of the device while open and powered up should be avoided and in any case should only be carried out by trained personnel who are fully aware of the risks which the operation entails, following the instructions given in the Maintenance section.

When the mains is disconnected using the main switch S1 of the Conveyor Control System, the power supply section is deactivated, but the contacts which are connected permanently to the mains, e.g. the relay outputs, remain energised.When the I2 service switch is turned off, most components remain energised.

4.1 – Periodic MaintenanceThe following is a list of maintenance operations and their suggested frequency.

Operation Frequency Operator Procedure

Preventive maintenance

At the beginning of each shift

Operator

Visual check of the integrity of the components and check of safety components

On changing product type

Periodically

Detection check

At the beginning of each shift

Quality-control operator;Head of quality control

Par. 3.6.1On changing product typePeriodically

Check the bearings Periodically Operator

Verifica visiva del corretto funzionamento dei cuscinetti.

Cleaning

At the beginning of each shift

Operator Par. 4.2.1On changing product typePeriodically

Cleaning of the conveyor belt When needed Operator Par. 4.2.2

The operator must monitor the condition of the system and its suitability for use and consult the maintenance personnel if necessary.

Page 46: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

46 FI002K0024v1000UK

4.2 – Periodic Maintenance procedures

4.2.1 – External cleaning instructions

Use only products compatible with stainless steel (AISI 316), PETG and silicon.

Do NOT use HYDROCHLORIC ACID or its solutions.

Use a slightly moist, non-abrasive cloth.

Do NOT use any other cleaning procedure.

Page 47: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

47FI002K0024v1000UK

4.2.2 - Cleaning the parts in contact with the product

In order to clean the parts in contact with the product, follow the procedure described in section 4.2.3. Only use the materials indicated in the following table:

BA

E B

E

C

C

D

A E

B

A

D

C

C

THS/xx21E and THS/xx21 THS/FBB THS/FB

EBA

AC

C

CE

B

C

C

C

BC

C

C

THS/MBB THS/M65 and THS/M69K THS/MBR

A B C D EWater up-to-50°C

* WARNING.Risk of material damage

to acrylic glass parts.Do not use alcohol

for cleaning.Alcohol causes cracks on some components

not in contact with the product, but still

exposed and reachable during cleaning

operations.

up-to-80°CDistilled water up-to-30°CAlkaline and acid-based pharmaceutical cleaning agents

Take careful note of the detergent used specifications

Mild soap solutionsHydrogen peroxide

up-to-28%

Caustic soda Solution-25%Sulphuric acid 10%Phosphoric acid 50%Oxalic acidAlcohol * up-to-30%Ammonia solution

Allowed - Not allowed

Page 48: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

48 FI002K0024v1000UK

4.2.3 - Cleaning of the Conveyor belt

Shut down the system at the main switch.

4.2.3.1 - Ejection systemIf the conveyor belt is fitted with an ejection system, perform with the following steps, before continuing:

THS/FBB and THS/MBB ejection system

Unlock the transparent cover of the ejection area, using its key

Remove the transparent coverfrom the ejection area

Empty product from the bin, then lift it up and remove it

from its supports

THS/FB, THS/M65 and THS/M69K ejection system

Unlock the transparent cover of the ejection area, using its key

Remove the transparent coverfrom the ejection area

Page 49: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

49FI002K0024v1000UK

4.2.3.2 - Belt disassembly

THS/FBB

Unlock the belt by raising the idle roller support

Extract the idle roller fromthe side supports

Pull the idle roller out of the belt

Raise the support surface from its position and pull it out of

the belt

Remove the guard from the cover using a no. 10 box

spanner

Remove the drive roller from the guides on the other side of the motor thus freeing the

support surface

Raise the support surfacefrom its position and from

the belt

Open the drive roller and remove the belt which is now free and ready to be cleaned

To refit the belt, follow this procedure in reverse order

Crushing and cutting hazard. When you are positioning the support surface on the entrance side, take precautions to prevent the risk of crushing and cutting between the surface and the belt frame.

Page 50: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

50 FI002K0024v1000UK

THS/FB

Unlock the belt by raisingthe idle roller support

Extract the idle roller fromthe side supports

Pull the idle roller out of the belt

Raise the support surface from its position and pull it out of

the belt

Pull the other roller outof the side supports

Remove the roller from the belt

Raise the support surfacefrom its position

Pull the surface out of the belt, that now is free and ready to

be cleaned

To refit the belt, follow this procedure in reverse order

Crushing and cutting hazard. When you are positioning the support surface on the entrance side, take precautions to prevent the risk of crushing and cutting between the surface and the belt frame.

Page 51: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

51FI002K0024v1000UK

THS/MBB and THS/MBR

Using a screwdriver, push one of the pins of the modular belt

out of its seat

Remove the pin completely from the modular belt, to open the belt. Remove the belt from

the structure and clean it

When you have cleaned the belt, return it to its position and

refit the pin

Page 52: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

52 FI002K0024v1000UK

4.3 - Troubleshooting

4.3.1 - Self-resetting protections

• The ALM card power supply inputs are protected by self-resetting components PTC.• The inverter outputs are electronically protected against short circuit between two phases

and between each phase and the ground.• The ALM card inputs are protected against wrong connection up to the voltages present on

the board itself, with the exception of the mains voltage.

4.3.2 – Troubleshooting table

Symptom Probable cause Action

Power supply unit or Metal Detector system OFF

No line voltageVerify-the-presence-of-the-main-voltage:-If-the-problem-persists,-contact-the-Maintenance-Service.

Unstable or partial connectionsMalfunction of the power supply section

Power supply unit or Metal Detector system alternates between ON and OFF Malfunction of the power

supply section

Switch-off,-wait-a-few-minutes-to-let-any-self-resetting-components-inside-cool-down,-then-switch-on-the-system-again.-If-the-problem-persists,-contact-the-Maintenance-Service.

Metal Detector does not give an alarm in the presence of metal masses of the same type as the reference sample and of equal or greater mass

Wrong detection parameters for the current product

Contact-the-Maintenance-Service-that-will-proceed-as-described-in-the-Installation-and-Maintenance-Manual.

SCD card malfunction

Metal Detector gives false alarms with no product in transit

Environmental interference

SCD card malfunction

Line voltage insufficient or unstable

Page 53: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

53FI002K0024v1000UK

4.3.3 - Self-diagnosis

The internal diagnostic system monitors the operational status of the Metal Detector. If a fault is detected, the following are activated in addition to a message on the display: the alarm warning lights, the buzzer, the fault relay (if the Fault Relays parameter is ON) and the flashing light (if FR=ON). Fault status can only be reset by eliminating the cause of the fault.

Message Probable cause and Action NO COMMUNICATION Fault in communication between SCD and ALM cards

Contact service technician EMERGENCY The emergency button has been pressed

Release the emergency button and press E to reset the alarm status

NO EJECT.CONFIRM Ejection of material not carried out Check that the ejector is not blocked. When the cause of the fault has been eliminated, press the E key to reset the alarm status. If the problem persists, contact service technician

BIN FULL Storage container fullEmpty it and press E

LOW AIR PRESSURE Compressed air pressure too lowCheck the compressed air connection. When the cause of the fault has been eliminated, press the E key to reset

POW. SUPPLY FAULT Power-supply section faultyContact service technician

MOTOR FAULT Overloading of the belt motorRemove the cause of overloading and press E keyWrong setting of motor parameters Contact service technician

PROBE FAULT(x) Probe connection broken or probe damagedContact service technician indicating the message and the value of x

TEST TIME OUT Time-out for pre-programmed test

Carry out the test SPM NOT DETECTED Memory faulty or absent (THS-system-not-operative)

Contact service technician COMPATIBIL.ERROR SCD card incompatible with the SPM memory card

Use compatible SCD card (ask service personnel)V SUPPLY TOO HIGH Power supply voltage too high

Check that the voltage is within the range on the rating plate

Page 54: Manual Detector de Metales

Operator Manual THS/21E and THS/21 Industrial Metal Detectors

54 FI002K0024v1000UK

Message Probable cause and Action LOGIN RESTRICTED Three attempts to access with the wrong password or

User ID have been made. Contact the Programming SupervisorEVENT BUFFER FULL Event memory buffer full

Contact the Programming and Data management supervisor EJECT.SYSTEM JAM Ejection system faulty or blocked

Check that the ejector is not blocked. Check the ejector connections. When the cause of the fault has been eliminated, press the E key

TEST FAILED The test was not successfulCheck for the actions to be taken in section 3.5.3

BIN ABSENT Storage container not in placeReturn the bin to its position and then press E

SELF-BALANCING The Metal Detector is in Automatic Balancing Status Wait until the end of the procedure

EXTERN.EMERGENCY The external emergency button has been pressedRelease the external emergency button and press E to reset the alarm status

EMERG.CIRC.FAULT Emergency stop circuit faultyCheck it and repair it if necessary

RESET EMERGENCY The emergency stop button needs to be reset Release the external emergency stop button and press E to reset

EJECT CHECK FAULT Ejection of material not carried out correctly Check that the ejector is not blocked. Check photocell operation. When the cause of the fault has been eliminated, press the E key to reset the alarm status

SYNC PHOTOC.FAULT

Photocell malfunction or pack stuck in front of photocell Check there is no pack stuck in front of the photocellCheck the photocell connectionsCheck the positions of the photocell and the retroreflector.Contact service technician

CHECK PHOTC.FAULT

ENCOD.FRQ.TOO LOW Speed measured by Encoder is out of rangeCheck encoder wheel movement.Contact service technician

ENCD.FRQ.TOO HIGH

Page 55: Manual Detector de Metales

Operator ManualTHS/21E and THS/21 Industrial Metal Detectors

55FI002K0024v1000UK

Message Probable cause and ActionINVERTER NOT RESP The inverter module is not connected or operating

Contact service technicianEJEC.OUT OF ORDER The ejector position is wrong

Check the operation of the ejector.Check the efficiency of the ejector position sensor

ALR RATE TOO HIGH Alarm rate too high The system need to be manually reset

WAIT UPDATING CONFIG Updating the configuration

(at-start-up-or-changing-the-transmission-channel)Wait until the end of the procedure. The system will reset automatically.

Vin FAULT Fault Vin voltage Contact service technician.

Vout FAULT Fault Vout voltage Contact service technician.

SCD CARD FAULT(X) SCD card faulty Contact service technician.