Page 1: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

Marine application manual

www.aquametro.comVD 7-100

e 0

5.20

13

Page 2: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

CONTOIL® flow meter

Rotary piston flow meter� Reliable, well proven measuring principle� Highly accurate measurement� Independent of temperature and viscosity� Minimum pressure loss� No seals (maintenance-free)� Insensitive to strong mechanical vibrations

Large Display with operating buttons � Easy to read numbers� Clear indication of displayed values� Menu-driven operation� Simple access to values and parameters� Fail-safe operation� Parameters change with protected access

Two programmable electronic outputs� Choice of 2 output types

- 1 analoque (4...20 mA)- 2 digital out (solid state relay)

� Choice of 4 functions for each digital output- Volume pulse (totalizer)- Frequency signal (flow rate)- Limit switch (min / max)- Limit switch (State alarm / error)

Maximum Standard High Maximum Approx.Minimal continuous accuracy accuracy filter size chamber

Type flow rate flow rate VZF VZFA* before FM volumeL/h L/h % % mm cm3

VZF(A) 15 10 400 1.0% 0.5% 0.08 12VZF(A) 20 30 1000 1.0% 0.5% 0.08 36VZF(A) 25 75 2000 1.0% 0.5% 0.1 100VZF(A) 40 225 6000 1.0% 0.5% 0.1 330VZF(A) 50 750 20000 1.0% 0.5% 0.1 1200

* VZFA type flow meters can be calibrated in pair for SL (0.1%) and RL (0.3%) Flow meters are available in DIN, JIS & ANSI flange types and threads

12

43

56

Out.1

Out.2

6...30V DC

Page 3: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

Design Guidelines Flow sensors are accurate measurement devices, which need some considerations in design and care during installation. Any measuring sensorcan only perform in the optimum range, when it is used within it’s specific requirements. Please consider application specific limit values.

Pump

CONTOIL®

Pulsationdampers

Pulsationdampers

CONTOIL®

Engine

Filter

Pulsationdampers

Tank

Auto Filter

Negative influencing factorsList of factors which can influence the performance of the flow meter negatively

Further we want to give some consideration for the whole fuel pipe installation:

Direct measurement of consumption for totalizing fuel consumption

Differential measurement of consumption for real-time and totalizing of fuel consumption

Medium� Seawater� Acid� Cleaning products

Mechanical� Pulsating pressure� Cat fines� Pre-Filter mesh size

Specification� Dimension to small� Over temperature

Page 4: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

Temperature and density compensationIf fuel oil consumption is compared in mass instead of volume, it is important to know the exact density which is affected by the temperature, hence it's essential toinstall temperature sensors close to the flow meter. Depending on the process it can be around 1% difference in consumption per 10°C temperature difference.Aquametro recommends to have a density sensor installed to measure it online. If no sensor is available, density values of the bunker report can be used.

Sample calculation for differential measurement

ASSUMPTION:Standard calibration 1 % accuracy (CONTOIL® VZF):� Supply (FM#0) 10’000 l/h ±1 % = ±100 l/h� Return (FM#1) 10’000 l/h ±1 % = ±100 l/h� Max. difference 2 % = 200 l/h

ASSUMPTION:pair calibration 0.1 % & 0.3 % accuracy (CONTOIL® VZFA):� Supply (FM#0) 10’000 l/h ± 0.1 % = ±10 l/h� Return (FM#1) 10’000 l/h ± 0.3 % = ±30 l/h� Max. difference 0.4 % = 40 l/h

Offset and differential measurementWith Aquametro Fuel Performance Management Systems like: Fuel Performance Recorder (FPR), CONTOIL® Fuel Monitor-S (CFM-S), CONTOIL® Fuel Monitor-T(CFM-T), these compensation calculations are done automatically, according to DIN 51757.

Sample calculation with direct and differential measurement

ASSUMPTIONS:� All Flow meter 1 % accuracy� M/E consumption 4’000 l/hr� A/E SL: 3000l/hr; RL: 2600l/hr� Circulation pump 10’000 l/hr

� Accuracy M/E with A/E running� FM2: 1 % of 3’000 l/hr � 30 l/hr� FM3: 1 % of 2’600 l/hr � 26 l/hr

� 30 + 26 l/hr = 56 l/hr of 400 l/hr � A/E consumption 14 % error� FM0: 1 % of 4’000 + 400 l/hr ➩ 44 l/hr� Total accuracy of M/E = 44 + 56 = 100 l/hr of 4000 l/hr � M/E consumption 2,5 % error

Sample calculation with 2x differential measurement

ASSUMPTIONS:� All Flow meter calibrated in pair: (0.1 % / 0.3 accuracy)� M/E SL: 10’000 l/hr; RL: 6’000 l/hr� A/E SL: 3'000 l/hr; RL: 2'600 l/hr

� Accuracy M/E with A/E running� FM2: 0.1% of 3’000 l/hr � 3.0 l/hr� FM3: 0.3% of 2’600 l/hr � 7.8 l/hr� 3.0 + 7.8 l/hr = 10.8 l/hr of 400 l/hr � A/E consumption 2.7 % error

� FM0: 0.1% of 10’000 l/hr à � 10.0 l/hr� FM1: 0.3% of 6’000 l/hr à � 18.0 l/hr� Total accuracy of M/E=10+18=28l/hr of 4’000 l/hr � M/E consumption 0.7 % error

ServiceTank

FM0

M/E

MT

FM1

ServiceTank

FM0

M/E

MT

A/E

FM2

FM3

Boosterpump

ServiceTank

M/E

MT

A/E

FM2

FM3

FM0

FM1

Boosterpump

Page 5: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

System Application for Offshore Vessels

RMS / FMCC� The perfect companion for all work boats� Automated data transfer to shore� Real time monitoring� Easy comparison between vessels

Fuel Tank 1 Fuel Tank 2

A/E 2

*Satellite connection with RMS system only

GPS

A/E 1

CFM-T / RMS*

LAN

M/E 2 M/E 1

SatelliteFMCC

These applications are suitable for Tug-, Riverboats and Offshore vesselswhere information of more than one engine is required

DFM-BC� Simple differential flow measurement� 1-2 flow meters in 1 pulse signal output� Perfect solution for bridge installation� Large display

F-Series� 1-2 flow meters with Analog or pulse output� Multiple outputs available� With or without real temperature compensation� Rough housing

Pump

CONTOIL®

Pulsationdampers

Pulsationdampers

CONTOIL®

Engine

Filter

Pulsationdampers

Tank

Auto Filter

DFM-BC

Our solution to monitor the consumption of one engine at the time.

Fuel Monitoring System

CFM-T � A multitalented monitoring system for all tugboats

and vessels consuming DO� Monitor multiple engines� Optional: count of Running hours and shaft rpm

Simplyfied Fuel Monitoring

Page 6: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

System Application for Ocean Vessels

FPM client SW� Data logger and trending software� Displays trends up to 6h� Receives data from CFM-S, FPR or CFM-T

Fuel Performance Recorder� The heart piece of monitoring equipment� Multiple analog inputs� Easy handling

Shaftmeter� State of the art shaft measurement equipment� Highly precise sensors. � Engine performance and ship efficiency

DO HFO

Diesel Switch

Viscosity Controller

Mixing Tube

CONTOIL®

Fuel meter

Viscomaster™

Shaft meter

GPS

FPR

FPM Client SW

Control Valve

LAN

Fuel Performance Mangement

Page 7: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

Viscomaster� Measure live viscosity and/or density� Easy installation or retrofit� Virtually maintenance free

Viscosity Controller� Display live values (viscosity and temperature)� Controls the heating cycle� Available alarm contacts

Control valve� The perfect companion to the Viscosity Controller� Exact steam or thermal oil flow control

Viscosity Controller

Viscomaster™

AMS

Mixing Tube

Control Valve

Diesel Switch� Your best friend for ECA zones� Automated change-over or blending� Protects engine from temperature shocks

Homogenizer� All the power with possible less consumption.� The shearing process is pure mechanical � Helps to reduce wear and tear

MixingTube

M/E

DO HFO

Diesel Switch

Homogenizer

Viscosity System

Diesel Switching System

Page 8: Marine application manual - Timer Elcon Application manual.pdf · Automated change-over or blending Protects engine from temperature shocks Homogenizer All the power with possible

Warranty Disclaimer

Aquametro guarantees the quality of the product in the context of its General Terms of Business.The ship yard, owner or operator will be liable for the correct installation as well as the appropriatehandling of the equipment upon its receipt.

� Please observe the application-, mounting- and operation- instructions!� Use the unit exclusively for its designed purpose.� Maintain the unit and service it according to prescriptions.� Use accessories only if their applicability is technically safe.� Warranty shall not cover in particular the following cases:� Inadequate installation works (please follow installation instructions)� Unsuitable or improper use� Faulty or negligent treatment� Excess load� Unsuitable operating equipment� Natural wear and tear� Product has been opened� Faulty assembly or start-up by the customer or third parties� Improper maintenance� Chemical, electronic or electrical influences� Corrosive media� Excessively high media and/or ambient temperatures� Broken separating plates due to missing pulsation dampers� Blocked flow meters due to missing strainers before the fuel meters.� Force majeure

HEAD OFFICE:

AQUAMETRO AG Ringstrasse 75CH-4106 TherwilPhone +41 61 725 11 22Fax +41 61 725 15 [email protected] www.aquametro.com

AQUAMETRO (CHINA) PTE LTD AQUAMETRO Japan AQUAMETRO KOREA LTD AQUAMETRO (S.E.A.) PTE LTD AQUAMETRO ME JLT 190 Woodlands Industrial Park E5 1-18-4, Nakane #501, Centum IS Tower, 190 Woodlands Industrial Park E5, Jumeirah Lake Towers#07-15 Woodlands BizHub Meguro-ku 1209 Jaesong-Dong, #07-15 Woodlands BizHub Jumeirah Bay X3, Office 1807 Haeundae-Gu P.O. Box 334132 Singapore 757516 / Singapore Tokyo 152-0031 / Japan Busan 612-050 / Korea Singapore 757516 / Singapore Dubai / UAE Phone +65 6899 1980 Phone +81 3 3723 8611 Phone +82 51 905 55 66 Phone +65 6899 1980 Phone +971 56 7587 801 Fax +65 6899 2972 Fax +81 3 5729 4607 Fax +82 51 905 55 69 Fax +65 6899 2972 [email protected] [email protected] [email protected] [email protected] [email protected]