marine switchboard and control console
TRANSCRIPT
Head Office 1497-1, Songjeong-Dong, Gangseo-Gu, Busan 618-817, Korea
Phone + 82 51 265 0255
Fax + 82 51 265 0250
Web Site http://www.kte.co.kr 10 -
2011
- K
TE C
o., L
TD. -
All
Rig
ht R
eser
ved
MARINE SWITCHBOARDAND CONTROL CONSOLE
Low Voltage SwitchboardHigh Voltage Switchboard
OkkenControl Console
KTE, as a company specializing in manufacturing and developing highquality marine electrical equipments since 1979, has contributed toproviding our valuable customers with world-class marine switchboard.Using the highest standards for our design, manufacture and ourinspection, while employing a state-of-the-art technology and know-how,we could not just to meet customer’s expectation but to exceed them aswell.
Now, we are utilizing all our competencies to develop ourselves as aglobally competitive company through new-value creation and innovation.We are making incessant effort to improve the quality of our product and tocreate customer-oriented future.
We help your safe journey and convenientoperation, saving your precious time.
High Voltage Swichboard
Low Voltage Swichboard
Engine Control ConsoleOne-man Bridge Control Console
Wing Control Console
:MARINE SWITCHBOARD AND CONTROL CONSOLE | 05take the sea with KTE 04
Main switchboards are not only recognized as useful means of power source protection butalso highlighted as central means for controlling power.
Specializing in the manufacture of marine electrical apparatus, KTE has so far developedvarious products adapted for the users’ needs on the basis of our long year expertise and thelatest technology.
We would like to introduce our trusted marine use switchboards, which meet the rules andregulations of the classification societies of various countries such as ABS, BV, CCS, DNV, GL,LR, NK and KR.
FEATURESLong life span and reliability
KTE marine switchboards are adaptable to all possible ship conditions
as the most reliable components have been chosen on the basis of
over 28 year accumulated experiences.
Excellent anti-corrosive coating, baked melamine finish and orderly
device arrangement make the switchboards more reliable.
Rigid construction and safety
The switchboards are sufficiently drip-proof and durable against vibration, moisture, heat and shock.
KTE has also acquired Type Approval Certificates from Germanischer Lloyd for switchboards.
From design stage of the products, KTE throughly reflects all the safety rules and regulations of
international standards and classification societies to the switchboards.
Best suited arrangement
Almost all type of marine switchboards have already been delivered in large quantities. Which means
that system satisfies various user requirements and are ready for immediate applications
Rules and regulations
KTE has acquired Type Approval Certificate for Low Voltage Switchgear System from Germanischer
Lloyd. KTE maritime switchboards also meet the rules and regulations of the classification societies of
various countries including ABS, BV, CCS, DNV, LR, GL, RINA, NK, KR.
MARINE SWITCHBOARDLOW VOLTAGEDraw-out type GroupStarterThe switchboards incorporatingdraw-out type group starters aremade particularly small to reduceinstallation space and facilitateonboard switchboard arrangement.
Draw-out UnitDraw-out Unit is divided into main
circuit instrument room and control
circuit instrument room, both of which
are safe and enable easy
maintenance inspection.
:MARINE SWITCHBOARD AND CONTROL CONSOLE | 07take the sea with KTE 06
SPECIFICATION- Type : Total-enclosed, dead-front
- Rated insulation : Voltage AC1000V
- Rated voltage : Up to AC690V
- Rated current : Up to 9300A
- Rated frequency : 50/60 Hz
- Maintenance : Front and rear
- Protection degree : IP 22
- Short circuit strength (Icw / Ipk) :
Up to 130 KA / 330 KA
Type test of KTE’s LV Switchboard for Germanischer Lloyd Certification- Rated short-time withstand current (Icw) : up to 130 KA
- Rated peak withstand current (Ipk) : up to 330 KA
POWER MANAGEMENT SYSTEM- Full protection functions for generators, large consumers and tie-breakers
- Easy installation and maintenance
- Flexible addition or modification of function
- Flexible replacement of I /O or CPU
- Easy confirmation and control by using TFT touch operation panel
- Flexible communication connection with external system(IAS, INS, AMS, VDR, etc.)
- Class approved components (ABS, BV, DNV, GL, LR, etc.)
APPLICATION- Crude oil tanker
- LNG / LPG carrier
- Container carrier
- Product / Chemical tanker
- Bulk carrier
SYSTEM DESIGNFor the best suited arrangement in each switchboard room, KTE Switchboard system may be arranged in many different ways. (Some samples are listed below.)
- Single row, Self-standing,
Against a wall.
- Corner arrangement,
Self-standing, Against a wall.
Emergency Switchboard
Front Maintenance Type
- Double rows facing each other
with an encapsulated bus duct.
:MARINE SWITCHBOARD AND CONTROL CONSOLE | 09take the sea with KTE 08
MARINE SWITCHBOARDHIGH VOLTAGE
MCset series, adapts to all electrical power distribution requirements from 1 to 24KVfor marine and off-shore applications, is a complete range of High Voltagestandardized units.
MCset offers you :- Pre-engineered and adaptable solutions tailored
to your specific requirements
- Significantly reduced maintenance
- Local support centres throughout the world
MCset gives you the advantages of :- Continuity of service for your network
- Enhanced safety for your staff and operation
- Optimized investment throughout the life of your installation
- The possibility of integrating your HV SWBD in a monitoring and control system
MCset solidly based on extensive experience acquired throughout the world andprovides your networks with a high level of dependability and safety.
MCset integrates a host of innovative solutions designed around proventechniques: high performance switchgear, digital protection, monitoring andcontrol system, enclosures capable of withstanding internal arcing.
MCset has taken account of three key user requirements :
Reliability- Type testing was carried out for each performance level
- Three-dimensional computer modeling techniques
were used to study the electrical filed
Simplicity - A user interface which is easily understood by everybody
- Interlocks and padlocks preventing operator errors
- Sepam-type protection units enabling on-site information retrieval
without any additional devices
- Easy installation due to identical civil engineering dimensions for
all cubicles and installation being possible against a wall
Safety - Operations are all performed from the front, including access to connections and
busbars
- The earthing switch has making capacity
- Internal arc withstand developed for all functional units
:MARINE SWITCHBOARD AND CONTROL CONSOLE | 11take the sea with KTE 10
The standard units are- Incoming and outgoing units with or
without voltage transformer (VT)
- Bus-tie with or without voltage transformer (VT)
- Bus riser with or without voltage transformer (VT)
- Motor units
Breaking techniques- SF6, Rollarc contactors
- SF6, LF circuit breakers
Standard compliance- IEC 60298-60694
- IEC 60056 (circuit breakers)
- Classification (LRS, DNV, BV, RINA, ABS, GL)
HV MOTOR STARTER, MOTORPACTAn innovative range of motor starters up to 3800KW
Low installation cost- 2 unit pre-assembled shipment
- Integrated low voltage wireway
- Front and rear access to cable compartment
High reliability- Disconnector housing and contactor cradle moulds
- Fewer busbar connections
- Temperature rise = 55°C- Pre-engineered solutions with LPCT and Sepam digital relay
- KEMA Certified (STL)
Easy to use- All controls located at the same convenient operator height
- Visible isolation and “earthed” indication at eye-level
- Optional back-light to view contact position
- Ensures reliability and operator ease
- Prevent access to HV compartment when energised
- Maintainable from the front
Operating conditonsMotorpact HV motor starters provide the most efficient means to controland protect a wide range of applications.
- Rated voltage : 7.2 KV
- Motor range : Up to 3800 KW
- Motor type : Asynchronous
- Enclosure types : Squirrel cage
- Up to IP 4X
- Internal arc classified
Connected position Rail extended Withdrawn position
Load compartment with vacuum contactor
DESCRIPTION OF A FUNCTIONAL UNITA functional unit comprises all equipment in the main and auxiliary circuits which together provide a protection function.
The cubicleIncomer or Feeder[AD] / Line up bus section[CL-GL]
/ Busbar metering and Earthing[TT] / Switch-fuse feeder[DI]
The protection, monitoring and control systemSepam / Current sensor / Voltage transformers / Zero
sequence core balance CT’s (CSH type)
The withdrawable partCircuit breaker or contactor / Lever type propulsion
mechanism / Interlocks to fix the withdrawable part
:MARINE SWITCHBOARD AND CONTROL CONSOLE | 13take the sea with KTE 12
FOR SPECIAL PURPOSEOKKEN
Okken’s safety and high operational dependability are essential for your applications incritical processes, in power distribution as well as for motor control.
Okken is a totally type-tested switchboard, in accordance with IEC 60439-1, and certifiedby independant labs: LOVAG, ASEFA, CESI and VIRLAB
High dependability and low voltage switchboardOkken is a low voltage switchboard designed for use in critical large-site applications:
- Off-shore platforms
- Large industrial plants
Okken high safety and availabilityswitchboard up to 6300A
Wide range of solutions- Withdrawable device for high power incomers or feeders up
to 6300 A,
- Fixed for economical low-power feeder applications.
- Disconnectable up to 630 for a high upgradeability
- Plug-in up to 630 for fast interchangeability without handling
the power cables
- Drawers for highest availability and safety of electrical
distribution and motor control
Protection levels: IP31, IP41, IP54
230 and 115 Masterpact cubicle
Masterpact are installed in- 115 columns up to 4000A,
- 230 columns above 4000A.
Connection from the top, the bottom or the rear
Short-circuit current up to 150kA/1s
Highly compact configurations- Incomers changeover in 1 column
- Incomers+Coupling in 2 columns
:MARINE SWITCHBOARD AND CONTROL CONSOLE | 15take the sea with KTE 14
Drawers
Designed for the best continuity of service - Padlocking and locking plugged in or withdrawn
- «Test» Position for checkings
- Evolutions in the feeder or the configuration,
Without having to switch off the main power supply
Variable speed drives
Fixed or Drawer mounting of variable speed drives
Ventilation unit per unit
Up to 4
Fuses cubicle
630 to 1500A Vertical busbar
Direct mounting of horizontal fuses switch
Fixed type cubicle
Fixed PCC - Form 2 to form 4a
- Units up to 1600 A.
- Current transformers in the connection compartments.
Simple technology- Predrilled distribution busbar
- Bolted connections
- Flexible links makes it easier to connect each feeder.
Disconnectable or Plug-in Polyfast
Without having to switch off the mainpower source, it allow
- Evolutions in the switchboard
- Devices’ settings,
- Addition, change or removal of feeders
- Curative maintenance
Prevent any on-load handling,
Okken Polyfast prevents the risks of short-circuit upstream the protection device
Power factor correction
Power factor correction and harmonicfiltering
- Eliminate reactive power related costs,
- Limit contractual demand,
- Increase energy availability,
- Improve energy quality,
- Extends the life of the connected devices
| 17:MARINE SWITCHBOARD AND CONTROL CONSOLE take the sea with KTE 16
KTE, a specialized manufacturer of marine equipment, produces control consoles whichassure safe ship navigation along with switchboards and starters.
FEATURESLong life span and high performance
KTE marine control consoles are adaptable to all possible ship conditions. They are highly resistant to
vibration, moisture and temperature, employing parts chosen on the basis of our high technology and
accumulated experience. Thus, long life span and high performance are ensured.
Optimum arrangement
For easy monitoring and operation, the layout of the panel surface
is sectioned for separate group apparatuses, such as the main
engine, the boiler and the auxiliary machinery. This arrangement
can fully meet user’s requirements.
Rigid construction and good appearance
Designed for marine applications, the consoles are sufficiently drip-
proof and durable against vibration and shock, and are
constructed for easy installation. Excellent anti-corrosive coating,
baked melamine finish, and orderly device arrangement produce a
superb appearance.
Easy inspection and maintenance
The arrangement of the parts in the console and the wiring
facilitates inspection and maintenance.
MARINE CONTROL CONSOLECONTROL CONSOLE
ROTTERDAMMILAN
ATHENS
DUBAI
SHANGHAI
HONG KONGKAOHSIUNG
KTEKTE DALIAN TAIYO
NPC
SINGAPORE
JAKARTA
SYDNEYFREMANTLE
HAMBURG
LOS ANGELES
NEW YORK
BRAZIL
MARSEILLE
SPAY
LONDON
SHEFFIELD
BUSANKTE CO., LTD.TEL : 82-51-265-0255 / FAX : 82-51-265-0250http://www.kte.co.kr
DALIANKTE DALIAN CO., LTD. No. 33 Shimen Road, Changxing Island.Harbor Industrial Zone, Dalian, China.
LOS ANGELESDUTHIE POWER SERVICESTEL : 1-310-790-1772 / FAX : 1-310-491-0987http://www.duthiepower.com
NEW YORKB&A MARINE CO.,INC.TEL : 1-718-875-6700 / FAX : 1-718-858-0029http://www.bamarine.com
THE ARNESSEN CORPORATIONTEL : 1-908-241-3535 / FAX : 1-908-353-8030(Have associated companies at Vancouver, San Francisco, New Orleans, Miami)
BRAZILMETALOCK BRASIL LTDATEL : 55-13-3226-4686 / FAX : 55-13-3226-4680http://www.metalock.com.br
SHEFFIELDROTARY ELECTRICAL SERVICES LTD.TEL : 44-114-276-9901 / FAX : 44-114-272-5073http://www.rotaryelectrical.co.uk
HAMBURGARKNOAH SHIP MANAGEMENT GMBHTEL : +49-40-80-900-6970FAX : +49-40-80-900-6971http://arknoah.com/
ROTTERDAMCOFELY WEST INDUSTRIE BVTEL : 31-10-2831200 / FAX : 31-10-2831300http://www.cofely-gdfsuez.nl
MARSEILLESNEF ELECTRIC-FLUXTEL : 33-91-989094 / FAX : 33-91-030609(Have branches at Brest, Le Harve)
ATHENSFRANMAN LIMITEDTEL : 30-210-9532 350 / FAX : 30-210-9532 355http://www.franman.gr
DUBAIMARITRONICSTEL : 971-4-3247500 / FAX : 971-4-3242500http://www.maritronics.com
TOKYOTAIYO ELECTRIC CO., LTD.TEL : 03-3293-3061 / FAX : 03-3292-7002http://www.taiyo-electric.co.jp
OKAYAMANAKASHIMA PROPELLER CO.,LTD.TEL : 81-86-279-5111 / FAX : 81-86-279-3595http://www.nakashima.co.jp
SHANGHAITAIYO ELECTRIC CO.,LTD. SHANGHAI LIAISON OFFICETEL : 86-21-62415961 / FAX : 86-21-62346939http://www.taiyo-electric.co.jp
SHANGHAI CYCLECT ELECTRICALENGINEERING CO.,LTDTEL : 86-21-64341256 / FAX : 86-21-64345113http://www.cyclect.com.sg
KAOHSIUNGRESON ELECTRONICS INT’L INC.TEL : 886-7-815-0036 / FAX : 886-7-815-1438(Have branches at Keelung, Taichung)
HONGKONGTHE SUN MARINE RADIO ENGINEERING CO.TEL : 852-2855-9613 / FAX : 852-2855-0519http://www.sun-marine-eng.jp/
SINGAPORECYCLECT ELECTRICAL ENGINEERING PTE LTD.TEL : 65-6863-6877 / FAX : 65-6863-6260http://www.cyclect.com.sg
JAKARTATAIYO ELECTRIC CO.,LTD. JAKARTA LIAISON OFFICETEL : 62-21-629-7074 / FAX : 62-21-629-7045http://www.taiyo-electric.co.jp
FREMANTLEREADS ELECTRIC CO., PTY. LTD.TEL : 61-8-9335-9344 / FAX : 61-8-9335-9465http://www.readselectric.com.
SYDNEYDOWDING & MILLS (AUSTRALIA) PTY.LTD.TEL : 61-2-9638-6333 / FAX : 61-2-9638-4723(Have associated companies at Brisbane,Melbourne)
http://www.dowdingandmills.com.au
We offer credible after sales services and are proudof the quality of our after sales service.
Any after sales services can promptly be arranged atmore than 20 world major ports.
Furthermore, KTE can also provide quality services forour products anywhere in the world throughoutI.S.E.S. (International Ship Electrical & EngineeringServices Association).
We are responsible to keep the service records fromthe birth to end of each vessel.
Therefore, KTE ensures continued reliable operationof your vessels.
SERVICE NETWORKCustomers are recommended to contact KTE first.
I.S.E.S(International Electrical & Engineering Services Association) SCHNEIDER’s CIS(Customer International Support) network also available everywhere in the world for HV Switchboard, Okken & all the Schneider’s products.
Electrical & Mechanical services available
Electrical services available
Mechanical services available
Please visit our Website http://www.kte.co.kr