marseille - bmi monier
TRANSCRIPT
The interlocking tile from the 19th century Large-format - Low-profile tile � 13/m2
marseille
43,3 cm
26 cm
For any projects developed within the context of an HQE® approach, an Environmental and Health Declaration Sheet for this tile is available on request.
* Usual fitting tolerance stated apply from actual average gauges and widths checked on delivery as per DTU.
3 Variable gauge : a great flexibility of laying
3 The “Bee” mark exclusive to Monier
MARSEILLEOverall dimensions in cm
The firing process of the clay may produce slight differences in colour. To obtain a roof with a homogeneous appearance, we recommend mixing tiles from different pallets. The printing processes do not necessarily guarantee a faithful reproduction of colours. Ask to see them in situ.These values are given for information purpose only and are likely to change.
Type Clay roof tileTreble lock and double lapping, variable gauge
Number of tiles per m2 ≈ 12,5 to 14Unit weight ≈ 3,4 kgWeight per m2 ≈ 42,5 to 47,6 kgOverall length ≈ 43,3 cmOverall width ≈ 26 cmLinear cover ≈ 22,3 cmVariable gauge 36 to 32 cmLongitudinal fitting tolerance ≈ 0,2 cm*Transversal fitting tolerance ± 0,2 cm* Linear metre of battens/m2 2,8 to 3,2 mlLaying Broken bond from right to leftProduct standard NF EN 1304 Application standard NF P 31-202 [DTU 40.21]Silicone product An additive is required for beddingNumber of tiles per pallet 240Weight per pallet 820 kg
PresCriPTiON reCOmmeNDaTiON
gUaraNTee
TeCHNiCal CHaraCTerisTiCsThe tile shall be in terracotta from the large-format low-profile tile, treble lock double lapping and variable gauge, 12,5 to 14 per square meter, type Marseille from Monier or similar. Its fitting tolerance should be 4 cm long and 0,4 cm transverse. It shall be laid broken bond from right to left, on battens according to the standard of NF application NF P 31-202 [DTU 40.21]. Its installation shall be carried out using all parts specially designed for dry mortarless laying of ridges and edges as specified in the DTU.
COlOr KeY
Red Rustique Brown Valmagne Copper
This tile has been developedand tested in the windtunnel at the MonierTechnical Center.
30YEARS
FROSTRESISTANCE
30 YEARS
FROSTRESISTANCE
CLAY TILESClass 1 watertightness
freezing resistance trials carried outaccording to NF EN 539-2
www.marque-nf.com
CONCRETE ROOF TILESwww.marque-nf.com
CONCRETE ROOF TILESwww.marque-nf.com
MCLAY TILES
Class 1 watertightnessfreezing resistance trials carried out
according to NF EN 539-2www.marque-nf.com
CLAY TILESClass 1 watertightness
freezing resistance trials carried outaccording to NF EN 539-2
www.marque-nf.com
MFP
The wide range of Marseille fittings offers two choice of verge finishes :• universal verge tile 33,• standard verge right or left.In some regions, the Marseille ridge tiles (90° angle) are used as plastered verge.Verges direction is determined by placing them facing the pitch.A neoprene washeris used for fastening.
Monier recommends laying dry with ventilated weather stripping in a roll.
This system enables the ridge and hip to adapt to the nature movements of the roof.
The ridge courses are made by cutting the tiles closest to the ridge board.
All ridges and hips must be fastened with a clip.
The dry ridge/hip is quick to lay, provides good ventilation, and makes future work easier.
THe maiN feaTUres
Interlocking end hip "40"
Interlocking hip tile "40"
Marseille ridge tile 3 way apex
(1) Related to the surface area projected horizontally (2) Except for Spirtech® type breathing roof underlays.
Typeof attic
TotalVentilation (1)
S = 1/5 000
S = 1/3 000
S1 = 1/5 000 S2 = 1/3 000 (2)
S1 = 1/5 000S2 = 1/3 000 (2)
The underside of the tile and their support must be ventilated. This ensures overall correct behaviour of roofing components over time. The use of ventilation tiles is recommended at the upper and lower parts of the roof. The total of ventilation openings must be distributed equally between lower part of the roof slope and near the ridge. Humid or foul air outlets from the ventilation or extraction of living areas by forced mechanical ventilation or other systems, must be routed out of attic spaces. For further information on these two points, please refer to the DTU in force.Preferably, exhaust tiles are to be located at the top of the slope.
Note :
for better performance, the through tiles must be laid as much as possible near ridges.These values are given for information purpose only and are likely to change.
VERGES
Marseille ridge tile40 or 50Universal
ridge board support
Ridge board
Ventilated ridge/hip
4,5 ± 0,5 cm
HIP / RIDGE
AERATION, VENTILATION AND ILLUMINATION
Screw 70Screw 50
MortelMortelHalf-tile
multiple of lc 1/2 tile = 15,3
(tile = 25,4)
Half-tile
25,5 multiple of lc 1/2 tile = 15,3
(tile = 25,4)
wAkAFlEx® 28(28 cm)
Dimensions in cm
Half tile Standard verge left
Standard vergeright
Universal verge tile 33left
Universal verge tile 33 right
End verge 33left
End verge 33right
Laying with universal verges 33 Laying with standard verges
Dimensions in cm - lc : linear cover
15,8
43,318,2
7
43,7
14,5
8,5
Working height 11,5 5
43,7
14,510,8
23,522,5
38 37,5
24
37,518,2
METAlROll®
(26/32 cm)
2145
22,5
Working heightsmall part : 5,2
Marseille ridge tile 40 (120° angle)
1945
Working heightsmall part : 6
22,5
Marseille ridge tile 40 (90° angle)
3 way apex
1321
22,2
53,5
26
Marseille ridge tile 50 (90° angle)
46
35
End ridge n°1
24,246,5
20,8Overall heightsmall part : 8
Interlockinghip tile “40”
24,2
48,5
20,8Overall heightsmall part : 7,2
Interlockingend hip “40”
13
4 way apex
2134,2
31,2
7,2
End ridgefor cloaked verge
lantern (Ø 120 mm)
Ventilation tile with grid(opening 12 cm2)
26,3
43,3
Through tile (Ø 120 mm)
26,3
43,3
26
43,3
Glass Tile
FIGAROll® plUS(28/32 cm)
VALLEy AND EAVES
UNDER-ROOF
LAyING TILES IN A SqUARE LAyOUTFor violent winds, MONIER recommends going beyond the DTU recommendation and therefore fastening all tiles.(1) The wind zones considered are those designated by the snow and wind loads code (NV 65).(2) One tile fastening every five tiles laid. Map reference NV65On verges and eaves, all tiles must be fastened. Use of Europanneton® MAR Inox recommended by Monier.
MINIMUM PITCH TABLE IN %
DEFINITION OF SITES ACCORDING TO THE DTUSITES
Sheltered
Normal
Exposed
DEFINITION low ground, entirely surrounded by hills which protect it against all wind directions. Site partially bounded by hills in the direction of the most violent winds that provide protection against winds in this direction only.
plain or plateau with slight vertical intervals, whether extensive or not (valleys, undulations).
Near the sea: inland to a distance of 5 km; the tops of cliffs, islands or narrow peninsulas, estuaries or sheltered bays and ria.Inland: narrow valleys into which the wind is channelled, isolated and high mountains (for example: Mont-Aigoual and Mont-Ventoux) and certain mountain passes.
This breakdown into three zones should not be confused with the breakdown into Snow and Wind regions given in the NV (Snow and Wind) rules.
All tiles on the eaves must be fastened. Please refer to the DTU in force :• Europanneton® MAR Inox for eaves.Monier proposes a range of preformed valleys.Laying of a ventilated eaves batten (ventilation 200 cm2/ml) on the tilt batten guarantees linear ventilation in the lower section in accordance with the DTU’s recommendations.The dimension DE mentionned by Monier is given as an example. This dimension will vary according to several parameters : cant height, gauge, roof pitch and overhang d, and may be adjusted to achieve the required overlap. The interlocking part (water flow) must to be taken into account when defining dimensions DE and d.
Monier reserves the right to change the technical characteristics of its range.
THe maiN feaTUres THe regUlaTiONs
This d
ocum
entat
ion, w
hich w
as pu
blishe
d in 0
8/201
6, sup
ersed
es all
previo
us issu
es; it
is a no
n-con
tractu
al do
cumen
t that
may b
e revi
sed at
any t
ime.
Prod
uction
: DTP
: Cen
taure
- Pho
tos: P
. Zan
dvliet
- 3D
draw
ings: B
uster
Studio
- X
- Cen
taure
LR = Rake lengthDF = Ridge batten distance = 4,5 ± 0,5 cmDL = Battening distanceDE = Eaves batten distance = 33 cm To adjust for the desired overhang. d = Eaves overhang = 8 cm
49
Ornamental clay cockerel
24,5pinecone finial
(available in 44,5 cm)
37
18
ORNAMENTS57,5
Fleur de lysfinial
18
To prevent ingress of powder snow, the DTU recommends the use of an underlay. This use is also advocated by SNEST in order to catch and lead down to the gutter any small amounts of water as well as to protect against the ingress of dust or soot.
These data are applicable to slopes whose horizontal projection does not exceed 12 m. Building code recommendations.
Zones Zone I Zone II Zone III SitesSheltered 35 35 50 Normal 40 50 60 Exposed 60 70 80
MINIMUM ACCEPTABLE PITCHES IN % (NO UNDERLAy)
Zones Zone I Zone II Zone III SitesSheltered 30 30 45 Normal 35 45 50 Exposed 50 60 70
MINIMUM ACCEPTABLE PITCHES IN % (WITH UNDERLAy)
Pitches Zones 1 and 2(1) Zones 1 and 2(1) : Exposed site(1)
in % Protected and normal sites(1) Zones 3 and 4 : All sites Verges Running Verges Running and eaves portion and eaves portion p ≤ 100 all free all 1/5(2)
100 < p ≤ 175 all 1/5(2) all 1/5(2)
p > 175 all all all all
DF
DE
DLLR
d
profilo valleyVentilated eaves battenwithout comb
ZONES FOR THE APPLICATION OF MINIMUM PITCHESFrance is divided up into 3 zones for the application of minimum pitches (with regard to wind/rain concomitance)Note : if in doubt as to the zone of application, it is essentiall to refer to the definition of the zones given below.
ZONE IAll inland areas and the Mediterranean coastline for altitudes of less than 200 m.
ZONE II- Atlantic coastline up to 20 km inland, from Lorient to the Spanish border. - Strip between 20 to 40 km from the coast, from Lorient to the Belgian border. - Altitudes between 200 m and 500 m
ZONE III- Atlantic, Channel and North Sea coastline and inland to 20 km, from Lorient to the Belgian border. - Altitudes above 500 m and below 900 m.
SpAN-FlEx® 200
SpAN-FlEx®
300SpAN-AlU
300VApOTECH BBC
300ClIMA COMFORT
RENOClIMA COMFORT
SUN
ECOTECH®
200SpIRTECH®
110SpIRTECH®
200SpIRTECH®
300SpIRTECH®
200 BBCSpIRTECH® 300 BBC
SpIRTECH SUN200 BBC
Head Office: 23-25, avenue du Docteur lannelongue - 75014 ParisT : 01 40 84 67 00 - f : 01 40 84 67 01 www.monier.fr
fabienne alexandre - Export Manager - 23-25, avenue du Docteur Lannelongue - 75014 ParisT : 00 33 1 40 84 66 98 - e : [email protected] Perrot - Trade Export Assistant - B.P. 4 - 16270 Roumazières - France T : 00 33 5 45 71 88 92 - f : 00 33 5 45 71 88 93 - e : [email protected]