marshall moya design - washington, d.c. › sites › default › files › dc › sites ›...
TRANSCRIPT
Marshall Moya DesignNovember 7, 2012
Bradley Site Design, Inc Setty & Associates International, PLLC ReStl Designers, Inc. Polysonics Corp. Gorove/Slade Assoc. Delon Hampton & Assc. Sustainable Design & LEED TCT Cost Consultants
District of Columbia Department of General Services DGS
HORACE MANN ELEMENTARY SCHOOL
Existing Site Plan
Community Center
2 Story SChool
trailer - 1 Story
2 Storyprivate propertieS
trailer - 1 Story
ChurCh
trailer - 1 Story
exiSting Site plan
NEwARk ST Nw
MACOMb ST Nw
NEw
MExiC
O AvE N
w45
TH S
T N
w
Proposals for 2013 Renovation work + Addition
Original Option - Option 1building on 45th - Option 2
building on Community Room - Option 3
Option 1
DESIGN VISION 6District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 1 - Site analySiS
Proposed master plan supports all required program spaces by DCPS and its adjacencies.
interior circulation flow and connection of spaces are best achieved with this master plan option, including the internal connection between buildings A, b & C.
best visual connection achieved between campus areas.
Optimum exterior circulation flow and accessibility to all campus. Clear access of main entrance from street.
Maximum sun exposure with benefits to the students, teachers, and campus landscape. Specially during winter season.
Most cost efficient master plan proposal. USbG silver requirement is achieved.
This option has the LEAST amount of square feet to connect from 45th Street to the range.
12 FEET clear access from 45th Street to range. NO view to range.
Summary of Analysis Master Plan Pros:
Mann Master Plan - Option 1
Summary of Analysis Master Plan Cons:
DESIGN VISION 7District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 1 - Site plan
b
C
b
a
DESIGN VISION 8District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 1 - perSpeCtive vieW
neWark Street45th Street
range
field
a
b
C
+/- 12’ to property line
DESIGN VISION 9District of Columbia Department of General Services
Marshall Moya Design
DGS
W
W
s
GV
GV
E
xx
xx
xx
xx
xx
xx
xx
x
x x x x x x x x x x x x xx
xx
x
xx
x
x
x
x
xxxx
x
x
xx
x x x x x x
x
x
389.03
SW
TW=3
88.6
6
TW=3
89.8
4
TW=3
86.5
8
375
38
385
385
390
390
380
38
386
386
387
387
387
388
388
388
388
388
389
389
391
391
392
392
393
394
4
388
7.7'
33.0
'
40.8
'
128.
7'
8"W
16"W
16"W
16"W8"W
6"PI
NE
4"PI
NE
6"PI
NE
4"TR
EE
"TR
EE
10"T
REE
5"TR
EE
50"T
REE
12"T
REE
18"T
REE
12"T
REE
2"M
ULT
ITR
EE
15"T
REE
4"TW
INTR
EE
5"TR
EE5"
TREE
4"TR
EE
10"T
WIN
TREE
40"T
REE
20"T
REE
15"T
REE
TOP=387.30
TOP=384.97
//
//
12"S
12"S
12"S
UP
UP
DN
UP
DN
UP
UP
UP
UP
UP
UP
UP
391' - 6"
391' - 6"
GRADEN SPACE
LIVING(GREEN)WALL
GREENSPACE
OVERHEADCOIL ROLLINGDOOR
1881 SFLIBRARY
299 SFGIRLS RR
304 SFBOYS RR506 SF
EXTEND DAYCLASSROOM
72 SFELEC
69 SFTELECOM
566 SFPERF ARTS
390 SF
SUPPLY / STOR /RECIEVING
417 SFART GALLERY
793 SFART
762 SFMULTIP LAB
822 SFSCIENCE
302 SF
LIBRARY STAFF /WORKROOM
253 SF
MAILROOM /WORKROOM /STOR
266 SFSTAFF LOUNGE
215 SFPRINCIPAL
334 SF
WELCOMECENTER /SECURITY DESK
214 SFCOUNSELOR
185 SFEXTEND DAY
221 SF
PARENTRESOURCE /CONF ROOM
191 SF
LOUNGE /WARMING KIT
2509 SF
DINING /MULTIPURPOSE
113 SFSTAIR
51 SFRR
50 SFRR
Not EnclosedKITCHEN
127 SF
COOLER /FREEZER
140 SFDRY STOR
60 SFFOOD OFF
62 SFCUST / ENG OFF
346 SFSTAGE
70 SFSTOR
50 SFRR
103 SFVEST
35
2850 SFENTRY LOBBY
432 SF
DATA ENTRY /RECORDS / STAFF/ ASSIST.PRINCIPAL
171 SFHEALTH SUITE
829 SFK CLASSROOM - C
69 SFTELECOM
50 SFRR76 SF
K STOR
733 SF
PRE-KCLASSROOM - B
728 SFK CLASSROOM - B
79 SFPRE-K WORKRM
66 SFRR 5
75 SFRR 4
73 SFRoom
95 SFK WORKRM
63 SFRoom
764 SFK CLASSROOM - A
741 SF
PRE-KCLASSROOM - A
1575 SFCIRCULATION
53
49 SFPRE-K STOR
76 SFWORKRM
47 SFRR 3
45 SFJAN
405 SFCIRC
80 SFEXIST VEST
66 SFEXIST VEST
range
204’
- 7”
27’
102’
110’
31’
SportSfield
propoSal no. 1 - 1st level plan
12’
75’ -
3”
15’ -
10
1/2
”11
3’ -
5 1
/2”
129’ - 2”
DESIGN VISION 10District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 3 - elevationS
DN
UP
UP
OPEN TOBELOW
OPEN TO BELOW
OPEN TOBELOW
OPEN TOBELOW
GREEN ROOF
STUDIO SPACES STUDIO SPACES
STUDIOSPACE
STUDIOSPACE
MECHICAL ROOMABOVE STAGE
665 SF2ND GRADE - C
778 SF2ND GRADE - B
736 SF2ND GRADE - A
728 SF1ST GRADE - C
206 SF
TEACHERLOUNGE /WORKROOM
234 SFBOYS RR
230 SFGIRLS RR
256 SF
READINGSPECIALIST
732 SF1ST GRADE - A
737 SF1ST GRADE - B
492 SF
WORKROMMTEACHER OFFICE
307 SFBOYS RR
298 SFGIRLS RR
816 SF3RD GRADE - C
764 SF3RD GRADE - B
758 SF3RD GRADE - A
413 SF5TH GRADE - A
46 SFRoom
72 SFELEC ROOM
79
69 SFTELECOM
80
731 SF4TH GRADE - C
81 767 SF4TH GRADE - B
82 725 SF4TH GRADE - A
83
342 SF5TH GRADE - B
84
535 SF5TH GRADE - C
85
188 SF
SPEACH &LANGUAGE
86
182 SF
RESOURCE CONFRM
87
164 SFESL OFFICE
88
187 SF
OCCUPATIONALTHERAPHY
89
332 SF
RESOURCECLASSROOM
90
218 SF
INSTRUCTIONALCOACH
91
63 SFSTOR
92
432 SF
RESOURCEWORKROOM
93
106 SFLOUNGE SPACE 1
94
3161 SFCIRCULATION
95
461 SFCIR
96
350 SFLOUNGE SPACE 2
98
propoSal no. 1 - 2nd level plan
12’
DESIGN VISION 11District of Columbia Department of General Services
Marshall Moya Design
DGSpropoSal no. 1 - 45th Street vieW
Option 2
DESIGN VISION 13District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 2 - Site analySiS
Proposed master plan supports all required program spaces by DCPS and the majority its adjacencies.
interior circulation flow and connection of spaces are achieved with this master plan option, including the internal connection between buildings A, b & C.
best visual connection achieved between campus areas.
Optimum exterior circulation flow and accessibility to all campus. Clear access of main entrance from street.
Maximum sun exposure with benefits to the students, teachers, and campus landscape. Specially during winter season.
USbG silver requirement is achieved.
3rd floor addition lessens optimal flow and educational adjacencies are not fully achieved.
64 FEET Connection from 45th Street to the range. Partial view to range.
Summary of Analysis Master Plan Pros:
Mann Master Plan - Option 2
Summary of Analysis Master Plan Cons:
DESIGN VISION 14District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 2 - Site plan
b
a
b
C
DESIGN VISION 15District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 2 - perSpeCtive vieW
neWark Street45th Street
range
field
a
b
C
+/- 64’ to property line
DESIGN VISION 16District of Columbia Department of General Services
Marshall Moya Design
DGS
W
W
s
GV
GV
E
xx
xx
xx
xx
xx
xx
xx
x
x x x x x x x x x x x x x
xx
xx
xxxx
x
x
x
x
xxxx
x
x
xx
x x x x x x
x
x
x
x
389.03
SW
TW=3
88.6
6
TW=3
91.0
8
TW=3
89.8
4
386.
58
375
385
385
390
390
380
380
374
386
386
387
387
388
3
388
388
388
389
389
391
391
392
392
393
4
388
7.7'
12.3'
33.0
'
40.8
'
8"W
16"W
16"W
16"W8"W
6"PI
NE
4"PI
NE
6"PI
NE
10"T
REE
5"TR
EE
50"T
REE
12"T
REE
18"T
REE
12"T
REE
2"M
ULT
ITR
EE
15"T
REE
4"TW
INTR
EE
5"TR
EE5"
TREE
4"TR
EE
10"T
WIN
TREE
40"T
REE
20"T
REE
15"T
REE
56"T
REE
TOP=387.30
TOP=384.97
//
12"S
12"S
12"S
UP
UP
DN
UP
DN
UP
UP
UP
UP
UP
UP
UP
UP
391' - 6"
391' - 6"
GRADEN SPACE
LIVING(GREEN)WALL
GREENSPACE
OVERHEADCOIL ROLLINGDOOR
1881 SFLIBRARY
299 SFGIRLS RR
304 SFBOYS RR
536 SF
EXTEND DAYCLASSROOM
78 SFELEC
67 SFTELECOM
427 SFPERF ARTS
368 SF
SUPPLY / STOR /RECIEVING
716 SFART
628 SFMULTIP LAB
734 SFSCIENCE
302 SF
LIBRARY STAFF /WORKROOM
253 SF
MAILROOM /WORKROOM /STOR
266 SFSTAFF LOUNGE
215 SFPRINCIPAL
335 SF
WELCOMECENTER /SECURITY DESK
2644 SF
DINING /MULTIPURPOSE
614 SFKITCHEN
62 SF
COOLER /FREEZER
85 SFDRY STOR
96 SFFOOD OFF
70 SFCUST / ENG OFF
341 SFSTAGE
70 SFSTOR
50 SFRR
103 SFVEST
35
1228 SFENTRY LOBBY
434 SF
DATA ENTRY /RECORDS / STAFF/ ASSIST.PRINCIPAL
172 SFHEALTH SUITE
817 SFK CLASSROOM - C
68 SFTELECOM
50 SFRR76 SF
K STOR
731 SF
PRE-KCLASSROOM - B
728 SFK CLASSROOM - B
79 SFPRE-K WORKRM
66 SFRR 5
75 SFRR 4
77 SFRoom
100 SFK WORKRM
66 SFRoom
752 SFK CLASSROOM - A
741 SF
PRE-KCLASSROOM - A
1623 SFCIRCULATION
53
49 SFPRE-K STOR
76 SFWORKRM
47 SFRR 3
45 SFJAN
82 SFEXIST VEST
66 SFEXIST VEST
60 SFSHOWER
99
145 SFSTORAGE
105
126 SFSTORAGE
126
1615 SFCIRCULATION
127
propoSal no. 2 - 1st level plan
SportSfield
range
27’
30’
60’
31’
+/- 64’ to property line
162’
- 6
1/2
”
DESIGN VISION 17District of Columbia Department of General Services
Marshall Moya Design
DGS
DN
UP
UP
DN
OPEN TOBELOW
OPEN TO BELOW
OPEN TOBELOW
OPEN TOBELOW
STUDIO SPACES STUDIO SPACES
665 SF2ND GRADE - C
778 SF2ND GRADE - B
736 SF2ND GRADE - A
728 SF1ST GRADE - C
206 SF
TEACHERLOUNGE /WORKROOM
234 SFBOYS RR
230 SFGIRLS RR
256 SF
READINGSPECIALIST
732 SF1ST GRADE - A
737 SF1ST GRADE - B
350 SF
LLOUNCHESPACE 2
307 SFBOYS RR
298 SFGIRLS RR
816 SF3RD GRADE - C
764 SF3RD GRADE - B
758 SF3RD GRADE - A
46 SFRoom
720 SF4TH GRADE - B
82 719 SF4TH GRADE - A
83
221 SF
SPEACH &LANGUAGE
86
192 SFESL OFFICE
88333 SF
OCCUPATIONALTHERAPHY
89
473 SF
RESOURCECLASSROOM
90
240 SF
INSTRUCTIONALCOACH
91
102 SFSTOR
92
620 SF
RESOURCEWORKROOM
93
152 SFLOUNGE SPACE 1
94
778 SF4TH GRADE - C
106
78 SFELEC
62 SFTELECOM
289 SF
WORKROOMTEACHER OFFICE
109
3096 SFCIRCULATION
111
propoSal no. 2 - 2nd level plan
+/- 64’ to property line
DESIGN VISION 18District of Columbia Department of General Services
Marshall Moya Design
DGS
DN
GREEN ROOF
707 SF
5TH GRADEA115
707 SF
5TH GRADEB116
707 SF
5TH GRADEC117
334 SF
COUNSELOR118
239 SF
LOUNGE /WARMINGKIT119
281 SF
PARENTRESOURCE /CONF ROOM120 250 SF
EXTENDDAY121
78 SF
ELEC122
65 SF
TELECOM123
289 SF
TEACHERWORKROOM124
1375 SFCIRCULATION
125STUDIO SPACES STUDIO SPACES
propoSal no. 2 - 3rd level plan
DESIGN VISION 19District of Columbia Department of General Services
Marshall Moya Design
DGSpropoSal no. 2 - 45th Street vieW
Option 3
DESIGN VISION 21District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 3 - Site analySiS
Proposed master plan supports all required program spaces by DCPS
Clear access and orientation from main street.
72 FEET clear access from 45th St., to range. Unobstructed view to range.
Educational adjacencies required by DCPS are not achieved and the flow of programmatic spaces is disrupted.
interior and exterior circulation flow of spaces are NOT achieved with this master plan option, including the internal connection between buildings A, b & C.
it has the least visual connection between campus areas, requiring staff members to supervise multiple entry and exit points to/from multiple buildings.
Least amount of sun exposure to the students, teachers, and campus landscape. Specially during winter season the range will be in shadow during school hours.
Most expensive master plan proposal. USbG silver requirement might be compromised.
Summary of Analysis Master Plan Pros:
Mann Master Plan - Option 3
Summary of Analysis Master Plan Cons:
DESIGN VISION 22District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 3 - Site plan
b
a
C
b
DESIGN VISION 23District of Columbia Department of General Services
Marshall Moya Design
DGS
propoSal no. 3 - perSpeCtive vieW
neWark Street45th Street
range
field
a
b
C+/- 72’
DESIGN VISION 24District of Columbia Department of General Services
Marshall Moya Design
DGS
W
W
s
GV
GV
E
xx
xx
xx
xx
xx
xx
xx
x
x x x x x x x x x x x x x
xx
xx
xx
x
x
x
x
xxxx
x
x
xx
x x x x x x
x
x
x
x
389.03
SW
TW=3
88.6
6
TW=3
91.0
8
TW=3
89.8
4
TW=3
86.5
8
375
38
385
385
390
390
390
380
38
386
386
387
387
387
388
388
388
388
388
389
389
391
391
392
392
393
394
4
388
7.7'
12.3'
33.0
'
40.8
'
128.
7'
8"W
16"W
16"W
16"W8"W
6"PI
NE
4"PI
NE
6"PI
NE
4"TR
EE
"TR
EE
10"T
REE
5"TR
EE
50"T
REE
12"T
REE
18"T
REE
12"T
REE
2"M
ULT
ITR
EE
15"T
REE
4"TW
INTR
EE
5"TR
EE5"
TREE
4"TR
EE
10"T
WIN
TREE
40"T
REE
20"T
REE
15"T
REE
TOP=387.30
TOP=384.97
//
//
12"S
12"S
12"S
UP
DN
UP
DN
UP
UP
UP
UP
UP
UP
UP
UP
391' - 6"
391' - 6"
LIVING(GREEN)WALL
GREENSPACE
1881 SFLIBRARY
299 SFGIRLS RR
304 SFBOYS RR506 SF
EXTEND DAYCLASSROOM
74 SFELEC
70 SFTELECOM
738 SFPERF ARTS
333 SF
SUPPLY / STOR /RECEIVING
793 SFART
758 SFMULTIP LAB
822 SFSCIENCE
302 SF
LIBRARY STAFF /WORKROOM
253 SF
MAILROOM /WORKROOM /STOR
266 SFSTAFF LOUNGE
215 SFPRINCIPAL
334 SF
WELCOMECENTER /SECURITY DESK
342 SFCOUNSELOR
278 SFEXTEND DAY
260 SF
PARENTRESOURCE /CONF ROOM
215 SF
LOUNGE /WARMING KIT
2859 SF
DINING /MULTIPURPOSE
498 SFSTAGE
1245 SFKITCHEN
252 SF
COOLER /FREEZER 221 SF
DRY STOR
103 SFRR/SHOWER
149 SFFOOD OFF
70 SFSTOR
50 SFRR
103 SFVEST
35
2850 SFENTRY LOBBY
432 SF
DATA ENTRY /RECORDS / STAFF/ ASSIST.PRINCIPAL
171 SFHEALTH SUITE
829 SFK CLASSROOM - C
69 SFTELECOM
50 SFRR76 SF
K STOR
733 SF
PRE-KCLASSROOM - B
728 SFK CLASSROOM - B
79 SFPRE-K WORKRM
66 SFRR 5
75 SFRR 4
73 SFRoom
95 SFK WORKRM
63 SFRoom
764 SFK CLASSROOM - A
741 SF
PRE-KCLASSROOM - A
1250 SFCIRCULATION
53
49 SFPRE-K STOR
76 SFWORKRM
47 SFRR 3
45 SFJAN
80 SFEXIST VEST
66 SFEXIST VEST
701 SFCIRCULATION
63
59 SFRR
64
62 SFRR
65
97 SFSTOR
240 SFCIR
79
125 SF
CUST / ENGOFFICE
8061 SFJAN
81
272 SFRoom
8980 SFRoom
90
propoSal no. 3 - 1st level plan
SportSfield
range27
’
31’
72’
75’
60’ -
4”
160’ - 6”
46’
DESIGN VISION 25District of Columbia Department of General Services
Marshall Moya Design
DGS
DN
UP
OPEN TOBELOW
OPEN TOBELOW
OPEN TOBELOW
STUDIO SPACES STUDIO SPACES
STUDIOSPACE
OPEN TOBELOW
STUDIO SPACES
777 SF1ST GRADE - A
175 SF
INSTRUCTIONALCOACH159 SF
ESL OFF
261 SF
SPEACH &LANGUAGE
445 SF
RESOURCEWORKROOMCONFERENCE
214 SF
OCCUPATIONALTHERAPY
778 SF1ST GRADE - B 125 SF
CIR
776 SF1ST GRADE - C
2859 SF
DINING /MULTIPURPOSE
291 SF
RESOURCECLASSROOM
72 SFSUPPORT
72 SFRR
74 SFRR
67 SFSTOR
1178 SFCIRCULATION
496 SF
WORKROOMTEACHER OFFICE
307 SFBOYS RR
298 SFGIRLS RR
816 SF4TH GRADE - C
764 SF4TH GRADE - B
758 SF4TH GRADE - A
350 SFLOUNGE SPACE 2
446 SFCLASSROOM
70 SFTELECOM
74 SFELECTRICAL
758 SF5TH GRADE - C
763 SF5TH GRADE - B
725 SF5TH GRADE - A
150 SFLOUNGE SPACE 1
663 SF3RD GRADE - C
776 SF3RD GRADE - B
736 SF3RD GRADE - A
728 SF2ND GRADE - C
737 SF2ND GRADE - B
731 SF2ND GRADE - A
230 SFGIRL'S RR
111
206 SF
TEACHERLOUNGE /WORKROOM
112
256 SF
READINGSPECIALIST
113234 SFBOY'S RR
114
3702 SFCIRCULATION
45 SFJAN
57
propoSal no. 3 - 2nd level plan
DESIGN VISION 26District of Columbia Department of General Services
Marshall Moya Design
DGSpropoSal no. 3 - 45th Street vieW
DESIGN VISION 27District of Columbia Department of General Services
Marshall Moya Design
DGS
Renderings
DESIGN VISION 28District of Columbia Department of General Services
Marshall Moya Design
DGS
NEWARK STREET VIEW
entranCe vieW from neWark Street
DESIGN VISION 29District of Columbia Department of General Services
Marshall Moya Design
DGS
main entranCe vieW
Marshall Moya Design