Alarm Number: S01 003A Document Number: USA-E99981-111-* Revision Date: 07/16/01 CNC Systems Affected Servo System Spindle System Power Converter System Other Systems M600 Series MDS-A/B/C-Vx MDS-A/B/C-SP MDS-A/B/C-CV M60 Series MDS-A/B/C-SVJ/SVJ2 MDS-A/B/C-SPJ/SPJ2 MDS-A/B/C-CVE M50 Series MDS-A-CR M500 Series Alarm Summary Related Alarms In-Depth Analysis Corrective Action Mitsubishi Electric Automation, Inc. Technical Support & Service Group CNC Alarm Information Document 1) Check to see if machine is mechanically sound. Make sure the axis is not hitting the end of the ballscrew. Check to see if when the motor removed the axis will turn freely by hand. 2) If the alarm occurs at power on of the NC unit, disconnect the UVW wires leading to the motor, and cycle power. 3) If the alarm is not present then megger the motor and check the wiring going back to the motor for shorts. 4) If the alarm still exists then replace the drive unit. 5) If alarm occurs when speed command is given, remove the UVW wires from the drive unit. Give the drive unit a speed command. Does the 3B alarm appear or another alarm? If alarm 3B alarm appears, then replace the drive unit. If another alarm appears, check the wiring to the motor and megger the motor. 6) Exchange the drive unit. Overcurrent- The electrical current flowing to the drive unit exceeded the specifications of the drive. S01 0032, 0061 Electrical current flowing through the drive out to the motor is exceeding the specification of the drive. The alarm is more commonly seen on mechanical problems. The first thing to check is that you are not at the end of travel on the ballscrew for the axis. For further support, Contact: CNC Technical Support Group (847)478-2500, ext. 5 or email us at: [email protected] Document Status: For Reference Only

Upload: inlabo

Post on 16-Apr-2015

70 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Mds Alarm s01 003a

Alarm Number: S01 003ADocument Number: USA-E99981-111-*

Revision Date: 07/16/01

CNC Systems Affected Servo System Spindle System

Power Converter System Other Systems

M600 Series MDS-A/B/C-Vx MDS-A/B/C-SP MDS-A/B/C-CVM60 Series MDS-A/B/C-SVJ/SVJ2 MDS-A/B/C-SPJ/SPJ2 MDS-A/B/C-CVEM50 Series MDS-A-CRM500 Series

Alarm Summary

Related Alarms

In-Depth Analysis

Corrective Action

Mitsubishi Electric Automation, Inc. Technical Support & Service GroupCNC Alarm Information Document

1) Check to see if machine is mechanically sound. Make sure the axis is not hitting the end of the ballscrew. Check to see if when the motor removed the axis will turn freely by hand.2) If the alarm occurs at power on of the NC unit, disconnect the UVW wires leading to the motor, and cycle power.3) If the alarm is not present then megger the motor and check the wiring going back to the motor for shorts.4) If the alarm still exists then replace the drive unit.5) If alarm occurs when speed command is given, remove the UVW wires from the drive unit. Give the drive unit a speed command. Does the 3B alarm appear or another alarm? If alarm 3B alarm appears, then replace the drive unit. If another alarm appears, check the wiring to the motor and megger the motor.6) Exchange the drive unit.

Overcurrent- The electrical current flowing to the drive unit exceeded the specifications of the drive.

S01 0032, 0061

Electrical current flowing through the drive out to the motor is exceeding the specification of the drive. The alarm is more commonly seen on mechanical problems. The first thing to check is that you are not at the end of travel on the ballscrew for the axis.

For further support, Contact:CNC Technical Support Group(847)478-2500, ext. 5or email us at:[email protected]

Document Status:For Reference Only