Mechanical and Electrical requirement
Pumps
Water pumps
Due to the reports of unstable hydrostatic pressure in Kuala Krai water supply networks, it is advisable to install a pump to supply water to the elevated water tank. Moreover this pump is only allowed to operate when the hydrostatic pressure drops. Therefore an average multistage pump with the more than 25 feet is sufficient for the school. The Regaline Pumps Sdn Bhd has a suitable choose for the requirement.
Below are the details of the pump
Correlli Horizontal Pump
This is a horizontal stainless steel multistage pumps are widely used in domestic and commercial premises for pressure boosting where the existing water supply is insufficient to meet the demand requirement. Its compacted design ensures easy installation even in constrained spaces.
Operating condition
Capacity 2-30 M3/h
Head: 10-55 m
Fire Safety
Fire safety is the set of practices envisioned to decrease the destruction caused by fire. These measures include the methods of preventing ignition of uncontrolled fire and to limit development of fire after it starts. Fire safety is an important factor in any type of project, and especially in civil engineering project fire safety is given exceptional consideration starting from planning stage up to construction stage in order to reduce fatality. There are also law and regulation that must be followed to that a good fire safety rating is obtained.
For school a fire alarm is very important and should be fixed in a strategic place so that the alarm sound can alert people during fire outbreak. Along with smoke detector and heat sensor is a must to prevent the fire from development. Heat sensor and smoke detector should be fixed in very classroom, staffroom, storage rooms. Symbol and such fire assembly fire points and exits must be place in the school so that student and staffs can be directed to a safe assembly point.
Fire pump
According to Malaysia Fire safety act , the water supply for fire emergencies shall be obtained from atleast two centrifugal pumps of which one is electric motor-driven and one driven by a fully independent power source e.g. a diesel engine. In case if there is power outage during the fire, the independent power source engine can be used. The most suitable choose for fire pumps is offer by bomba ideal S.A company. They offer Foc Une Standard pump under their fire fighting package which is designed according to NFPA-20 standards of Malaysia.
Below are the description of this pump:-
01 Control panel for the diesel driven main pump
02 Valve
03 Rubber expansion joints
04 Discharge manifold
05 Pressure swith & manometer
06 Vessel
07 Flowmeter
08 Testline
09 Testing valve
10 Electrically driven main pump & jockey control panel
11 Check valve
12 Relief valve
13 Pressure swith
14 Main electric driven pump
15 Jockey pump
16 Main diesel driven pump
17 Double set batteries
18 Fuel tank
19 Emergency push button
Reference
http://www.bombas-ideal.com/Eng/Fire-Fighting-Packages/Bombas-Ideal-Foc-Cepreveb-RT2-ABA-Requirements-Set.html
https://www.scribd.com/doc/106198285/Building-Plan-Submission-What-Bomba-Wants
https://www.scribd.com/doc/135136903/General-Requirements-for-DBKL-bomba-English