MEMCOR® CS IIULTRAFILTRATION SYSTEMFURTHERING SUBMERGEDMEMBRANE SYSTEMS & LOWERINGTHE COST OF TREATED WATER

Page 2: MEMCOR® CS II ULTRAFILTRATION SYSTEM - Lenntech · Lenntech info@lenntech.com Tel. +31-152-610-900 Fax. +31-152-616-289 info@lenntech.com Tel. +31-152-610-900 Fax. +31-152-616-289

MAKING SUBMERGED MEMBRANE SYSTEMS EVEN BETTER !

MEMCOR® CS II system takes the features ofsubmerged membrane systems, such as: high solidshandling capability; low energy use; & low footprintand makes them better!

Building on over 30 years of experience in bothsupplying membranes and membrane systems, theMEMCOR CS II system is the latest addition to theMEMCOR product family. The system uses: thelatest enhanced PVDF UF membrane & potting thatis proven in the field; a proven backwash process;and enhanced the configuration to reduce bothcapital & operating costs.

The MEMCOR CS II system is ideal for newinstallations or for upgrades to existing Filtersystems or Clarifiers. By using “double ended”filtration & a longer module energy usage isreduced; cutting membrane operating costs;decreasing the plant footprint while deliveringexceptional value over the entire system life-cycle.

ABILITY TO TREAT THE MOST CHALLENGINGFEEDS

With MEMCOR CS II the modules sitsubmerged/immersed in an open tank. Each moduleis comprised of thousands of membrane fibers withmicroscopic pores on the membrane surface. As thewater passes through the fibers, particles greaterthan 0.04 µm are rejected by the membrane.

During each backwash the waste solids arecompletely drained from the tank which eliminatesmaldistribution and combined with a small diameterfiber bundle increases the solids handling capability.

PROVEN RACK, MODULE & PROCESS

The MEMCOR CS II MemRACK™assembly features:

· Proven L20N Modules: both highflux and high permeability;

· Uses Nylon Filtrate & Air rackcomponents from the Memcor CSMemRACK already proven in thefield;

· Seawater compatible option;

· Flexible configuration to fit totanks/cells of different sizes anddepths;

· Uses the proven Memcor CSbackwash process, whileachieving lower air usage; andlower membrane operating costs

· Suited to “Open Rack” technologyplatforms

HIGH TURBIDITY FEEDWATER

2

MEMCOR® CS II MemRACK

Page 3: MEMCOR® CS II ULTRAFILTRATION SYSTEM - Lenntech · Lenntech info@lenntech.com Tel. +31-152-610-900 Fax. +31-152-616-289 info@lenntech.com Tel. +31-152-610-900 Fax. +31-152-616-289

LARGE MEMCOR® CS SYSTEMADELAIDE DESALINATION PROJECT

LARGE SYSTEMS NEED RELIABILITY & LOW OPERATING COSTSThe enhanced modularity of the MEMCOR® CS IIsystem enables widespread implementation - eveninto competitor systems - and delivers greaterdesign flexibility. The number of modules in eachMemRACK™ array is variable up to 44 modules tosuit almost any size tank or configuration. TheMemRACK arrays ultra-compact footprint enablesdesigners to increase the capacity of their existingsubmerged system without having to add newcells/tanks.

All MEMCOR CS II systems are backed by thesuperior technical ability, experience, applicationknowledge and expert resources of Evoqua WaterTechnologies, an industry leader with more than1,800 installations and 400,000 modules inoperation worldwide.

MEMCOR® CS II SYSTEM FEATURES

• Proven L20N PVDF UF membrane module(tens of thousands of modules already in the field)

• Very low energy use• High solids handling capability• Proven process with more than 2,000 ML/d

(> 500 MGD) worth of installations• Retrofit able to existing Filter cells or competitor

submerged systems

3

The MEMCOR CS II system lowers the costof water produced• MEMCOR CS II operates under vacuum or

siphon and at the membrane Trans-Membrane Pressure (TMP) whichsubstantially reduces energy usecompared to pressure center systems

• Maximum filtration performance with40% lower footprint of previousMEMCOR membrane submergedsystems, which reduces the cost of newconstruction

• Simplifies operations and maintenancewith access to membrane modules fromthe top of the MEMCOR CSII MemRACK

• Scalable to meet wide range ofplant capacities

MEMCOR CS II are supplied as MemRACKand L20 modules to be installed into new orexisting concrete or steel structures.

Discover more about MEMCOR CS IIsystem today and visit:www.evoqua.com.au to learn more.

Page 4: MEMCOR® CS II ULTRAFILTRATION SYSTEM - Lenntech · Lenntech info@lenntech.com Tel. +31-152-610-900 Fax. +31-152-616-289 info@lenntech.com Tel. +31-152-610-900 Fax. +31-152-616-289

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

rob.visser
Getypte tekst
The information provided in this literature contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms and of the contract.