metal products ms-200™ installation guide · 2020. 11. 9. · manufacturer’s weather tightness...

48
MS-200™ Installation Guide TAYLOR METAL PRODUCTS BUTYL INJECTED SEAL (AVAILABLE) 2" BUTYL INJECTED SEAL (AVAILABLE) 2"

Upload: others

Post on 14-Nov-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

MS-200™ Installation Guide

TAYLORM E T A L P R O D U C T S

BUTYL INJECTED SEAL(AVAILABLE)

2"

BUTYL INJECTED SEAL(AVAILABLE)

2"

Page 2: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical
Page 3: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

Table of ContentsPanel Specifications ................................................................................ Floating Panel Clip ...................................................................................... Notes To Designer/Installer ......................................................................Taylor Delivery Fleet .................................................................................... Delivery, Will Call & Loading .......................................................................Standard Eave ........................................................................................... Hook Eave ................................................................................................. Gutter/Hook Eave ...................................................................................... Standard Ridge ......................................................................................... Vented Ridge ............................................................................................. End Dam Attachment ................................................................................. Valley Flashing ........................................................................................... Valley Flashing – Low Pitch ....................................................................... Standard Gable .......................................................................................... Alternate Gable ......................................................................................... Sidewall ..................................................................................................... Peak Flashing (R.E.C.) ..............................................................................Vented Peak Flashing (R.E.C.) .................................................................Pitch Change ............................................................................................ Endwall ...................................................................................................... Vented Endwall ......................................................................................... Saw Cut Endwall ....................................................................................... Back Pan ................................................................................................... Curb Side Wall .......................................................................................... Curb End Wall ........................................................................................... Curb/Pan Cricket ....................................................................................... Eave to Gable Transition .....................................................................Pipe Penetration – on Plate ...................................................................... Pipe Penetration – on Rib .................................................................... Pipe Penetration – on Pan ........................................................................

Flashing Selection ................................................................................

MS-200™Flashing and Details Guide

1

2-34

5-789

101112131415161718192021222324252627282930

31-3334

35-3637

38-41

TAYLORM E T A L P R O D U C T S

Page 4: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

TAYLORM E T A L P R O D U C T S

MS-200™MECHANICALLY SEAMED

2

• 12", 14-5/8" & 16" options available

• 24 & 22 gauge Tru-Gauge™ and .032" Aluminum

• Floating clip system: allows for expansion/ contraction of panels in longer lengths

• 2" Mechanical seam rib, 90° or 180°: Factory notching available

• Factory injected Butyl sealant

• Structural panel that will span up to 5'

• Concealed fasteners: fasteners cannot leak

• Manufactured in Sacramento, CA & Salem, OR

• - Code compliance UL Evaluation Report UL ER 25913-01

• UL 580 Class 90 Wind Uplift & UL Class A Fire rated

• UL Construction No. 90, 176, 180, 238, and 238A

• ASTM E-1592 - Structural uniform static air pressure ASTM 1646 - Water infiltration ASTM 2140 - Water infiltration ASTM 1680 - Air infiltration

• Weather tightness warrantly available (Contact TMP representative for details)

• 1/2:12 minimum pitch recommended (For lower pitches, please inquire)

• Standard panel lengths 3' to 60' (For longer panels, please inquire)

• 2' Shortcut capability - not notched (Fee applicable)

• Onsite roll forming available for long lengths

• Panel options: Striations, Accent Ribs, and Flat Pan

• Retro-fit systems available

STRIATIONS

ACCENT RIBS 2 Accent ribs for 12" & 14-5/8" panel3 Accent ribs for 16" panel

PANEL PROFILES

KEY FEATURES

BUTYL INJECTED SEAL(AVAILABLE)

2"

BUTYL INJECTED SEAL(AVAILABLE)

2"

90º SEAM DETAL 180º SEAM DETAIL

180 degree seams are not considered an architectural detail. The detail improves the weather tight-ness and wind uplift capabilities of the panel system, but will show stress and waviness in the seam. The detail is recommended for slopes less than 3/12, roof areas not easily viewed from the ground, and for high wind areas. For additional information, contact a TMP representative and DI Seamers for support and information about the proper use of seaming tools.

Page 5: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

3

These printed chips provide a close representation of the colors. Metal samples are available upon request. Coatings are low gloss 10-15% sheen.SRI = Solar Reflective Index. SRI values listed above are in accordance with ASTM E 1980 and are based on actual testing.***Oil canning is not a cause for material rejection***

11-20

Kynar 500

Commercial-grade metal primer

G-90 galvanizing

24 or 26 guage steel

G-90 galvanizing

Commercial-grade metal primer

Corrosion resistant primer

Kynar 500® paint layer

Commercial-grade metal primerGalvanized G-90 or AZ-50

Base SteelGalvanized G-90 or AZ-50Commercial-grade metal primerCorrosion resistant wash coat

STANDARD COOL KYNAR 500® COLORS

MATERIAL SPECIFICATIONS• 24 gauge Kynar 500® Painted Steel .0236" (Thickness prior to painting) Galvanized G-90 or AZ-50

• 24 gauge bare Zincalume® Plus AZ-55 (No finish warranty – 25 yr. perforation warranty)

• 22 gauge Kynar 500® Painted Steel .029" (Thickness prior to painting)

• .032" Kynar 500® Painted Aluminum

• 22 gauge Rusteel Plus™ (A606)

• 16 and 20 ounce Copper (Please inquire)

• Kynar 500® and substrate testing data available (See website)

• “Oil canning” is an inherent characteristic of roof and wall products, and not a defect, which is not a cause for panel rejection

KEY FEATURES• 21 Standard Colors, 5 Metallic Colors and 4 Specialized Colors

• Kynar 500® Paint System - the ultimate in exterior durability and color retention

• “Cool” color pigments are specially designed to reflect infrared light, reducing heat gain to dwelling, and conform with ENERGY STAR® criteria

• Superior Quality, two coat, 70% resin finish, applied at a 1 mil. thickness

• 40 year residential paint warranty

• 20 and 30 year commercial paint warranty: Contact TMP for warranty specifications

Gla

cier

Whi

te S

RI-8

5

40-Year Residential / 20 and 30 Year Commercial Manufacturer’s Limited Warranty

Sier

ra T

an S

RI-6

0

Parc

hmen

t SR

I-58

Ster

ling

Gre

y SR

I-44

Zinc

Gre

y SR

I-39

Cha

rcoa

l Gre

y SR

I-25

Sadd

le T

an S

RI-3

7

Med

ium

Bro

nze

SRI-3

6

Mus

ket S

RI-3

1

Dar

k Br

onze

SR

I-22

Taho

e Bl

ue S

RI-3

1

Paci

fic B

lue

SRI-2

6

Hem

lock

Gre

en S

RI-3

6

Fore

st G

reen

SR

I-24

Pine

Gre

en S

RI-2

5

Terra

Cot

ta S

RI-4

3

Tile

Red

SR

I-35

Col

onia

l Red

SR

I-37

Ret

ro R

ed S

RI-4

2

Met

allic

Silv

er S

RI-6

0

Cha

mpa

gne

SRI-4

8

Antiq

ue P

atin

a SR

I-40

Cop

per P

enny

SR

I-50

Wea

ther

ed Z

inc

SRI-3

9

16 o

z. a

nd 2

0 oz

. Cop

per

*ple

ase

inqu

ire* P

ure

copp

er

has

no w

arra

nty

Rus

teel

Plu

s™ (A

606)

Rus

teel

Plu

s™ h

as n

o m

etal

lic

coat

ing,

is u

npai

nted

and

has

no w

arra

nty

PREMIUM METALLIC COOL KYNAR® COLORS SPECIALIZED MATERIAL

✦ ✦ ✦ ✦ ✦

1,2 1,2 1,22 1,2 1,2 1,2 1,2 1,2

1,22 1,2 1,2 1,2 1,2 1,2 2 2

1,2 1 1 1,2 1,2 1,2

RIVERSIDE CA • SACRAMENTO CA • SALEM OR • SEATTLE WA • WOODINVILLE WA • WWW.TAYLORMETAL.COM

Vint

age®

SR

I-19

Vint

age®

has

a c

olor

rang

e th

at

can

vary

from

bat

ch-to

-bat

ch.

See

TM

P w

ebsi

te fo

r mor

e in

fo

Zinc

alum

e® P

lus

No

finis

h w

arra

nty

– 25

yr.

perfo

ratio

n w

arra

nty

Width Gauge Color LBS  SQFT LBS  LF14-­‐5/8" 24 1 1.36 1.6518" 24 2 1.28 1.9318" 22 1.61 2.42

15-­‐3/8" .032  Alum 0.6 0.9

Standard  Panels

Mat

te B

lack

SR

I-23

21,2

Gra

phite

Bla

ck S

RI-2

6(fo

rmer

ly: B

lack

)

Page 6: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical
Page 7: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

4

MS-200™Flashing and Details Guide

Taylor Metal Products MS-200TM - UL 90 Floating Clip

18 ga. Base/22 ga. Top

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

UL 580 Class 90 Wind Uplift Rated UL Class A Fire Rated

Page 8: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

5

MS-200™Flashing and Details Guide

TAYLORM E T A L P R O D U C T S

Notes to Designer/InstallerTaylor Metal Products is providing the following details as an aid in design. The details in this guide are not inclusive to all design situations. The designer/installer is responsible for modifications and should take into consideration all aspects of the project including climate conditions, such as, snow and wind, as well as, building code requirements, building design, building usage and maintenance requirements.

Installation should be performed only by qualified installers familiar with metal roofing systems and industry standards. For details not shown in this guide, refer to the Sheet Metal and Air Conditioning Contractors National Association (SMACNA) architectural sheet metal manual for proper design. For manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical representative.

The Standard gauge for all products in this guide is 24 gauge and the standard finish is Kynar 500®. We recommend specifying all flashings be the same gauge, color, and finish as the panels to insure long-term durability and color match.

SubstratesDetails in the manual are all shown over solid substrate. MS-200™ can be used over spaced purlins. For solid substrate, Taylor Metal Products recommends 5/8" plywood or metal decking.

UnderlaymentMinimum underlayment requirements are 30 lb. ASTM rated felt, a synthetic underlayment with Class A and ASTM UV protection technology or a high temperature self-adhering rubberized membrane. When choosing the underlayment, consider the roof slope, roof design, roof panel, and the climate.

Drag Load RequirementsAll panels must be pinned at one end to resist the drag load caused by snow loads, live loads, and the weight of the panel. Drag load is a function of roof slope, actual load and length of panels. Contact Taylor Metal Products for specific drag load requirements.

MS-200™ Installation Guide - 2020

Page 9: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

MS-200™Flashing and Details Guide

6

TAYLORM E T A L P R O D U C T S

Ventilation/InsulationIt is the responsibility of the designer to determine the material types needed to control condensation and to insulate and ventilate the roof system. Applications over rigid insulation may require blocking for solid attachment and framing the perimeter for installation of perimeter flashings.

Oil CanningFlat metal surfaces will display waviness commonly referred to as “oil canning.” Oil canning is caused by a variety of conditions. Steel mill tolerances, variations in or uneven substrates and roofing underlayments. Oil canning is a characteristic of metal roofing, not a defect and is not a cause for rejection. Taylor Metal Products offers MS-200™ with striations or accent ribs to help minimize oil canning.

Thermal MovementThe Panels and the flashings must be allowed to expand and contract, especially with longer length panels. The panel may need to have a slight gap where the panel hooks the offset cleat to allow for thermal movement of the panels.

Snow DesignThe following details do not address all conditions for snow environments. Consult with the designers, engineers, and others for acceptable details to accommodate your project and climate conditions. When possible gutters, valleys, pitch changes or other penetrations should be minimized in snow areas.

All roof penetrations should be located as close to the ridge or “pin point” top of roof. Snow country requires special designs for valleys to accommodate accumulation of snow and ice from uphill panels. Roof design should be considered in snow areas. Roof design should help resist the melting and freezing of snow and ice.

A fit for purpose roof design has the greatest impact on maintaining a damage free roof system in snow areas. Please contact a Taylor Metal Products representative for assistance in detail designs and appropriate panel selection for specific climate and building conditions.

MS-200™ Installation Guide - 2020

Page 10: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

7

TAYLORM E T A L P R O D U C T S

MS-200™Flashing and Details Guide

Handling / Storage & SafetyHandle materials with care when off-loading or moving materials to avoid damage to panels or flashings. Long panels may require two or more pick-up points, properly spaced to avoid damaging panels. Plan ahead; contact Taylor Metal Products for recommendations on handling/hoisting long panels.

Store the panels, flashings and accessories in a dry, well ventilated area, off the ground. If covering, allow ventilation around panels. Elevate one end of bundle to allow drainage of wet materials.

Wear clean, soft-soled shoes when walking on roofing panels to avoid damage to the painted finish.

Take care that sand, gravel, dirt, etc. sticking to your shoes is not carried onto the roof, scratching or otherwise damaging the finish on the roofing material. Walking on asphalt impregnated felt paper, especially on a hot day, can cause the asphalt to stick to your shoes and be tracked on to the roofing material.

Take care when painting to avoid getting over spray on the roofing material. Remember that wind can carry paint particles some distance. Over spray can cause the finish of the roofing material to look dull and may void your warranty.

Secure materials, especially when leaving the site, on the ground or roof to prevent winds from moving the materials. Wind-blown materials may cause damage to the material, property or persons.

Always use proper safety equipment and attire to minimize risk of cuts or other injuries.

Do not walk on panels that have not been completely installed.

Do not walk on major ribs of panels.

Metal roofs that are wet or dusty can be extremely slippery. Wear soft soled shoes and a safety harness to minimize risk of falling.

Avoid installing metal panels in windy conditions.

Safety considerations are the responsibility of the installer and his crew. Be sure to and use common sense generally accepted safety practices when installing roofing materials.

MS-200™ Installation Guide - 2020

Page 11: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

8

TAYLORM E T A L P R O D U C T S

Taylor Delivery FleetDelivery FleetTaylor Metal Products prides itself with quick lead times delivered with our fleet of semi trucks. Our fleet of trucks are owned and operated by TMP. All of our drivers are Taylor Metal Products employees, so when your truck rolls in to deliver, you are dealing with Taylor Metal Products. Expect consistant and exceptional service with short leadtimes. The inhouse fleet allows for efficient and cost-effective delivery.

MS-200™ Installation Guide - 2020

Mounted on the rear of our truck's trailer, the trailer-mounted "Piggy-Back" forklift will accompany you right to your place of use, opening up unprecedented possibilities in terms of transportation. It can travel sideways, carrying panels up to 40' long, allowing delivery in locations that would typically be considered impossible to reach.Save time and effort while avoiding potential loading and transport issues; have experienced TMP personnel deliver and unload your order.

Page 12: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

9

TAYLORM E T A L P R O D U C T S

Delivery & Will Call/Loading

Will Call & LoadingFlatbed trailers and trucks are best suited to transport metal roofing materials. These can be loaded from the side with a forklift and tied down in a safe and secure manner.

We are not able to load materials onto vehicles and/or trailers which are not suitable or may be hazardous to load. Please be aware that if we find a vehicle to be inappropriate, we reserve the right to refuse to load your order.

Unacceptable examples include: boat trailers, vans, buses, motor homes, campers and box trailers. Pickup racks which do not have sufficient supports for the weight or are not long enough to support bundles are also unacceptable.

Taylor Metal Products is not responsible to tie down loads nor do we provide any tie down materials. Please bring tie downs to secure your load (string or twine are not acceptable for this purpose).

Consider having your order delivered on one of our trucks with a piggy back forklift.

DeliveryWe will make every attempt to deliver material to the desired location. We may be unable to gain access on tight corners or steep terrain. If the site is deemed inaccessible by our driver, the customer may choose an alternate delivery site within a reasonable proximity. If we are unable to make the delivery, additional charges may be assessed.

The customer is responsible for:• Determining adequate access for delivery

ahead of time.• Meeting the delivery at the agreed upon

time.• Providing adequate resources (1-4 people

as needed) for off loading materials.• A charge of $100 per hour may be added

for deliveries that go beyond their allotted time.

• Checking the shipment at the time of delivery.

• Verifying material quantities against the shipping/packing list.

• Noting any damage or discrepancies upon the paper work at the time of delivery and notifying Taylor Metal Products within 48 hours of delivery.

Delivery times are usually scheduled one day in advance. Taylor Metal Products will make every effort to make the delivery at the scheduled time. Please be aware that there may be conditions beyond our control such as traffic, mechanical failures, road closures, etc. which may affect our schedule.

MS-200™ Installation Guide - 2020

Page 13: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

Standard Eave

10

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

338"

112"

SPECIFYPITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

#10 SCREW 8" O.C.

UNDERLAYMENTOVER SCREW

DOUBLE ROW OFSEALANT

9" STRIP OFUNDERLAYMENT

STANDARD EAVE

OFFSET CLEAT

SEALANT

MS200 PANEL

FASCIA

SHEATHINGBEND NOTCHED PANELOVER CLEAT. LEAVE SPACE

FOR PANEL EXPANSIONAND CONTRACTION

SEALANT 8"FROM EAVE

SHEATHING

EAVE

9" UNDERLAYMENT STRIP

FASCIA BOARD

MS200 PANEL

UNDERLAYMENT

FIRST CLIP12" FROM EAVE

2" GAPIN SEALANT

SEALANT

SCREW EAVEUNDER PANEL

2- PAN/WAFERHEAD PER CLIP

SEALANT REQUIRED UNDER FLATAS SHOWN IN WET

ENVIRONMENTS ONLY(COASTAL / MARINE AND

WEST CASCADE MTNS)

OFFSET CLEAT

SCREW 8" O.C.

MS200 FlashingsFlashing and Details GuideEave / Hook Eave

STANDARD EAVE DETAIL

STANDARD EAVE(MS200ES)

Page 14: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

11

Hook Eave

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

2- PAN/WAFER HEADHEAD PER CLIP

SHEATHING

EAVE

9" UNDERLAYMENT STRIP

FASCIA BOARD

MS200 PANEL

UNDERLAYMENT

FIRST CLIP12" FROM EAVE

2" GAPIN SEALANT

SEALANT

SCREW EAVEUNDER PANEL

SEALANT REQUIRED UNDER FLATAS SHOWN IN WET

ENVIRONMENTS ONLY(COASTAL / MARINE AND

WEST CASCADE MTNS)

SCREW 8" O.C.

438"

1"

112"

58" KICK,

12" HEM,

OPEN

SPECIFYPITCH

IF PAINTED,THIS SIDE

HOOK EAVE

SCREW

UNDERLAYMENTOVER SCREW

DOUBLE ROW OFSEALANT

9" STRIP OFUNDERLAYMENT

MS200 PANEL

FASCIA

SHEATHINGBEND NOTCHED PANELOVER HOOK. LEAVE SPACE

FOR PANEL EXPANSIONAND CONTRACTION

SEALANT 8"FROM EAVE

HOOK EAVE DETAILHOOK EAVE(MS200EH)

MS200 FlashingsMS200 are 10' FlashingsHook Eave

Page 15: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

12

Gutter / Hook Eave

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

SCREW 8" O.C.

LAP UNDERLAYMENTOVER SCREW

DOUBLE ROW OF SEALANT

9" STRIP UNDERLAYMENTUNDER EAVE

HOOK EAVE

GUTTER HANGER

BOXGUTTER

NEOPRENE WASHEREDSCREW.

GUTTER TAPEREDTO DOWNSPOUT

MS200 PANEL

FASCIA

SHEATHING

SEALANT 8"FROM EAVE

5.5"

4"

3.25"1"

1"

.75"

IF PAINTED,THIS SIDE

12" HEM,

OPEN

2X 108°

6"

2- PAN/WAFER HEADSCREWS PER CLIP

SHEATHING

EAVE

9" UNDERLAYMENT STRIP

FASCIA BOARD

MS200 PANEL

UNDERLAYMENT

FIRST CLIP12" FROM EAVE

2" GAPIN SEALANT

SEALANT

SCREW EAVEUNDER PANEL

GUTTER HANGER

BOX GUTTER

SEALANT REQUIRED UNDER FLATAS SHOWN IN WET

ENVIRONMENTS ONLY(COASTAL / MARINE AND

WEST CASCADE MTNS)

1"13

16"

58"

538"

438"

1"

112"

58" KICK,

12" HEM,

OPEN

SPECIFYPITCH

IF PAINTED,THIS SIDE

HOOK EAVE WITHGUTTER DETAIL

MS200 Flashings

BOX GUTTER(MS200BG)

BOX GUTTER HANGER(AGH6)

Flashing and Details GuideGutter Eave

HOOK EAVE(MS200EH)

Page 16: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

13

Standard Ridge

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

4" LAP

4"

1" SEALANT SPACING

MS200PANEL

STANDARD RIDGE

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

INTO EACH END DAMDO NOT FASTEN INTO

STANDING SEAMS

SHEATHING

UNDERLAYMENT

NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE

SEALANT

SCREW END DAMTO SEAM

SPECIFY PITCH

IF PAINTED,THIS SIDE

12 " HEM,

OPEN

7"

STANDARD RIDGE DETAIL

MS200 FlashingsFlashing and Details GuideStandard Ridge

STANDARD RIDGE(MS200RS)

STANDARD RIDGE LAP

Page 17: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

14

Vented Ridge

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

3 ROWS OF SEALANT

NEOPRENE WASHEREDSCREW 4" O.C.

1"

4" LAP

SHEATHING

MS200 PANEL

SEALANT

SCREW END DAMTO SEAM

UNDERLAYMENT

VENTED RIDGE

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

TEK SCREW INTOEACH PANEL RIB

4" PERFORATEDSTRIP

NEOPRENEWASHERED

SCREW OR RIVETAT 12" O.C. INTOEACH END DAM.

DO NOT FASTEN RIDGECAP TO STANDING SEAM

SEALANTON TAB

SEALANT

8"

112"

58"

12" HEM,

OPEN

SPECIFYPITCH

IF PAINTED,THIS SIDE

4X 120°

MS200 FlashingsFlashing and Details GuideStandard Ridge

VENTED RIDGE DETAIL

RIDGE FULL VENTED(MS200RFV)

VENTED RIDGE LAP

Page 18: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

15

End Dam Attachment

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

SCREW ENDDAM TO PANEL

SEALANT ON TOP OFRIB TO FILL GAPS

AFTER END DAM IS INSTALLED,FILL ALL VOIDS ON FRONT SIDEOF END DAM WITH GUNNABLE SEALANT.

SEALANT

NEOPRENE WASHERSCREW 1" FROM RIB.4" O.C. MAY BE REQUIREDDEPENDING ON DRAG LOADREQUIREMENTS.

SCREW END DAMTO PANEL RIB

APPLY SEALANT ONBOTTOM AND SIDES

OF END DAM.

SEALANTUP SIDES OF RIB

AND ON TOP.

END DAMEND DAM SEALANT

SHEATHING UNDERLAYMENT MS200 PANEL

SCREW END DAMTO PANEL RIB

SEALANT TO FILL GAPS

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIBAND 4" O.C. MINIMUM, DRAGLOAD CALCULATIONS MAYREQUIRE MORE.

Page 19: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

16

Valley FlashingSlope 3:12 or Greater

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

1"11"

SPECIFY PITCH

IF PAINTED,THIS SIDE

1"

.5"11

2"

150° TYP.

THREE ROWS OFSEALANT AT LAP JOINT

6"LAP

1"

FIRST CLIP 12"FROM VALLEY

OFFSET CLEAT

SEALANT

DOUBLE ROW OFSEALANT

LAP UNDERLAYMENTOVER SCREW

UNDERLAYMENT

PAN/WAFER HEAD2 PER CLIP

SEALANT 8"FROM EAVE

FASTEN OFFSET CLEAT 8" O.C.SHEATHING

4" MIN.

MS200 FlashingsFlashing and Details GuideValley - 3:12 or Greater

VALLEY 24" FLASHING(MS200VF)

OFFSET CLEAT(MS200OC)

VALLEY 24" DETAIL(3:12 Or Greater Pitch)

VALLEY LAP(3:12 Or Greater Pitch)

Page 20: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

17

Valley Flashing - Low Pitch Slope Less than 1/2:12

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

4" MIN

SEALANT

NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.

TRIPLE ROW OF CAULK

UNDERLAYMENT

SEALANT 8"FROM EAVE

SHEATHING

IF PAINTED,THIS SIDE

1"

11"

SPECIFY PITCH

THREE ROWS OFCAULK

12"

MS200 FlashingsFlashing and Details GuideValley Flashing - Recommended Application Less than 3:12 Slope

VALLEY FLASHING( MS200VF)

LOW SLOPE VALLEY DETAIL(Less Than 3 :12 Pitch)

LOW SLOPE VALLEY LAP(Less Than 3 :12 Pitch)

Page 21: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

18

Standard Gable

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

134"

438"

134"

58" KICK,

1 " HEM,

IF PAINTED,THIS SIDE1

2"

NEOPRENE WASHERED SCREWOR RIVET 12" O.C.

SCREW WITHSEALANT OVER THE TOP

UNDERLAYMENTDOWN FACE 3" MINIMUM

SEALANT

SUPPORT FLASHINGBEND PANEL 90°

GABLE

SHEATHING

FASCIA21

8"

3"

1"

12"1

2"

18" 151°

UNDERLAYMENT

SHEATHING

FASCIA

SUPPORT FLASHING

SCREWWITH SEALANTOVER THE TOP

MS200PANEL

BEND PANEL 90°

NEOPRENE WASHEREDSCREW OR RIVET

GABLE

SEALANT

GABLE DETAIL GABLE(MS200G)

SUPPORT FLASHING(MS200SF)

MS200 FlashingsFlashing and Details GuideGable

Page 22: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

Alternate Gable

19

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

SEALANT

SUPPORT FLASHING

SCREW 8" O.C. WITHSEALANT OVER TOP

CLEAT SCREW

UPEND PANEL AT 90°

ALT. GABLE

SHEATHING

FASCIA

UNDERLAYMENTWRAPPED DOWNFACE 2"

SEALANT

CONTINUOUS CLEAT

ALT. L CLOSURE

212"

438"

58" KICK,

12" HEM,

OPEN

IF PAINTED,THIS SIDE

12"

1"

414"

12" KICK

IF PAINTED,THIS SIDE

218"

3"

1"

12"1

2"

18"151°

1"

134"

12" HEM,

OPEN

IF PAINTED,THIS SIDE

ALTERNATE GABLE DETAIL

ALTERNATE L CLOSURE(MS200ALC)

SUPPORT FLASHING(MS200SF)

ALTERNATE GABLE(MS200AG)

GABLE SUPPORT CLEAT(MS200GC)

MS200 FlashingFlashing and Details GuideAlternate Gable

Page 23: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

20

Sidewall

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

IF PAINTED,THIS SIDE4.5"

1.75"

12" HEM, 13

4"

LAP UNDERLAYMENTOVER SCREW

UNDERLAYMENTTURN UP WALL 8"

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

SCREW WITHSEALANT OVER THE TOP

SUPPORTFLASHING

BEND PANELEDGE AT 90°

SEALANT

WALL PANEL/SIDING

SHEATHING

SIDEWALL

MS200 PANEL

218"

3"

1"

12"1

2"

18"

151°

SHEATHING

WALL PANELLAP UNDERLAYMENTOVER SCREW

SEALANT

SUPPORTFLASHING

MS200 PANEL

SIDEWALL

UNDERLAYMENTTURN UP WALL 8"

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

BEND PANEL 90°

MS200 FlashingsFlashing and Details GuideSidewall

SIDEWALL DETAIL SIDEWALL(MS200SW)

SUPPORT FLASHING(MS200SF)

Page 24: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

21

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

Peak Flashing (Ridge End Cap)

4" LAP 1"

4"

LAP 4" WITH 3 ROWSSEALANT

MS200 PANEL

PEAK FLASHINGNEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

INTO EACH END DAM

SHEATHING

UNDERLAYMENT

NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE

SEALANT

538"

7"SPECIFY

PITCH

IF PAINTED,THIS SIDE

1" HEM,OPEN

58" KICK,

12" HEM,

OPEN

1"

514"

12"

SPECIFYPITCH

MS200 FlashingsFlashing and Details GuidePeak Flashing

PEAK FLASHING DETAIL PEAK FLASHING(MS200REC)

PEAK CLEAT(MS200RECC)

PEAK FLASHING LAP

Page 25: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

22

Vented Peak Flashing (Ridge End Cap)

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

SHEATHING

MS200PANEL

SEALANT

SCREW END DAMTO SEAM TAB

UNDERLAYMENT

VENTED RIDGE END

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND

4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

TEK INTOEACH PANEL RIB

4" PERFORATEDSTRIP

NEOPRENE WASHEREDSCREW OR RIVET AT 12"

O.C. INTO EACH END DAM.10" - VARIES PER SLOPE

VENTED RIDGE ENDCAP CLEAT

FASCIA

NEO TEK SCREW OR RIVET12" OC INTO END DAM

CLEAT SCREW12" O.C.

SEALANT

514"

12" KICK

IF PAINTED,THIS SIDE

1"

SPECIFYPITCH

6"

10"

58"

112"

IF PAINTED,THIS SIDE

SPECIFYPITCH

12" HEM,

OPEN5

8" KICK,1

2" HEM,OPEN

4" LAP 1"

4"

NEOPRENEWASHERSCREWS

SCREW ENDDAM TO PANEL

AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITHGUNNABLE SEALANT

SEALANTSEALANT ON TOP OFRIB TO FILL GAPS

MS200Flashing and Details GuideVented Ridge EndCap

PEAK FLASHING(MS200SW)

VENTED PEAK FLASHING DETAIL(Vented Ridge End Cap)

PEAK CLEAT(MS200RECC)

VENTED PEAK FLASHING LAP

END DAM DETAIL

Page 26: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

23

Pitch Change

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

4" LAP1" GAP

THREE ROWS SEALANT AT LAP JOINT

4"

FASTEN EVERY12" INTO END DAM,AVOID FASTENING INTO STANDING SEAM

TWO ROWS SEALANT

SHEATHING

UNDERLAYMENT, LAPOVER SCREW

MS200 PANEL

PITCH CHANGE FLASHING

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND

4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

FOLD PANEL END 180°,HOOK OVER OFFSET CLEAT

OFFSET CLEAT

FASTEN 8" O.C.

SPECIFY PITCH

IF PAINTED,THIS SIDE

4"

6"

12"

1"

12"

112"

MS200 FlashingsFlashing and Details GuidePitch Transition

PITCH CHANGE DETAIL

INSIDE PITCH CHANGE FLASHING

PITCH CHANGE LAP

OFFSET CLEAT(MS200OC)

Page 27: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

24

Endwall

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

MS200 PANEL

WALL PANEL

5"

6"

IF PAINTED,THIS SIDE

SPECIFY PITCH

LAP UNDERLAYMENTOVER SCREW

UNDERLAYMENT

NEOPRENE WASHERED SCREWOR RIVET AT 12" O.C.

WALL PANEL

MS200 PANEL

ENDWALL

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

SHEATHING

MS200 FlashingsFlashing and Details GuideHemmed EndWall

ENDWALL DETAIL

ENDWALL FLASHING(MS200EW)

Page 28: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

25

Vented Endwall

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

438"

5"

58"

112"

SPECIFYPITCH

2X 135°

IF PAINTED,THIS SIDE

12" HEM,

OPEN

WALLPANEL

TEK SCREWEACH PANEL RIB

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

SEALANT

NEOPRENE WASHEREDSCREW OR RIVET AT 12"

O.C. INTO EACH ENDDAM.

FASTEN 12" O.C.INTO EACH END DAM

4" PERFORATEDSTRIP

UNDERLAYMENT

UNDERLAYMENTOVER SCREW

SHEATHING

3 ROWS OF SEALANTAT LAP JOINT

NEOPRENEWASHERED

SCREW

4" LAP 1"

VENTED ENDWALL DETAIL VENTED ENDWALL FLASHING(MS200EWV)

MS200 FlashingsFlashing and Details GuideVented EndWall

ENDWALL LAP

Page 29: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

26

Endwall w/ Saw Cut Reglet

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

SHEATHING

MS200PANEL

UNDERLAYMENT

NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.

SEALANT

TUCK REGLET INTOSAW CUT, SET IN SEALANT

FASTENER24" O.C.

3 ROWS OF SEALANTAT LAP JOINT

NEOPRENEWASHERED

SCREW

4" LAP 1"

4"

5"

6"

IF PAINTED,THIS SIDE

SPECIFYPITCH

1" HEM,OPEN

358"

1"1

2" HEMAT 30°

IF PAINTED,THIS SIDE

12" HEM,

OPEN

SCREW ENDDAM TO PANEL

AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITHGUNNABLE SEALANT

SEALANT

SEALANT ON TOP OFRIB TO FILL GAPS

MS200 - FMFlashing and Details GuideSaw Cut EndWall

ENDWALL LAP

SAW CUT ENDWALL DETAILREGLET

(MS200RF)

ENDWALL(MS200EW)

END DAM DETAIL

Page 30: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

27

Back Pan & Soldered Back Pan

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

TAB SIDE WALL TO RECEIVE PAN

TAB AND RIVET BACK PAN

ENSURE END DAM UNDER SIDE WALL IS SEALEDFILL ALL VOIDS WITH SEALANT

HOOK BACK PAN TO OFFSET CLEAT

Z-CLOSURE

TAB SIDE WALL TO RECEIVE PAN

TAB AND RIVET BACK PAN

ENSURE Z-CLOSURE UNDER SIDE WALLIS SEALED, FILL ALL VOIDS WITH SEALANT

HOOK BACK PAN TOOFFSET CLEAT

Z-CLOSURE

1812"

512"

MS200 - FMFlashing and Details GuideBack Pan & Soldered Back Pan

BACK PAN DETAIL

SOLDERED BACK PAN / CRICKET DETAIL

BACK PAN(MS200PAN)

Page 31: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

28

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

Curb Sidewall

4"

4"

134"

IF PAINTED,THIS SIDE

12" HEM,

OPEN1"

1"

IF PAINTED,THIS SIDE

178"

WALLPANEL

LAP UNDERLAYMENTOVER SCREW

UNDERLAYMENT

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

SEALANT

CURB SIDEWALL

ZEE CLOSURE

NEOPRENE WASHEREDSCREW 8" O.C.

MS200 PANEL

SHEATHING

MS200 - FMFlashing and Details GuideCurb SideWall

CURB SIDEWALL(MS200CSW)

ZEE CLOSURE(MS200ZC)

CURB SIDEWALL DETAIL

Page 32: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

29

Curb Endwall

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

5"

6"

IF PAINTED,THIS SIDE

1" HEM,OPEN

MS200 PANEL

WALL PANEL

SCREW ENDDAM TO PANEL

AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITHGUNNABLE SEALANT

SEALANTSEALANT ON TOP OFRIB TO FILL GAPS

SCREW END DAMTO SEAM

SHEATHING

MS200PANEL

UNDERLAYMENT

NEOPRENE WASHEREDDRAG LOAD 1" FROMSIDE OF RIB AND4" O.C. MIN. DRAG LOADCALCULATIONSMAY REQUIRE MORE.

NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.

SEALANT

UNDERLAYMENTOVER SCREW

MS200 - FMFlashing and Details GuideCurb End Wall

CURB ENDWALL(MS200CH)

ENDWALL DETAIL

END DAM DETAIL

CURB ENDWALLDETAIL

Page 33: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

30

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

Curb / Pan Cricket(Slope 3:12 or Greater)

4" MIN

FIRST CLIP 12"FROM VALLEY

22 GA. OFFSET CLEAT,

SEALANT

DOUBLE ROW OFSEALANT

LAP UNDERLAYMENTOVER SCREW

CURB BACKPAN

CRICKET WHEN CURBIS WIDER THAN 24"

CURB BACK PAN / CRICKET DETAIL(3:12 Pitch or Greater)

4"

FIRST CLIP 12"FROM VALLEY

SEALANT

THREE ROWS OFSEALANT

NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.

UNDERLAYMENT

LAP UNDERLAYMENTOVER SCREW

#14 DEKFAST SCREW2 PER CLIP

CURB BACK PAN / CRICKET DETAIL( Less Than 3:12 Pitch)

MS200 - FMFlashing and Details GuideCurb Pan / Cricket3

12 Slope or Greater

Page 34: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

31

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

BEND UP 90°

CUT

REMOVE

BEND DOWN 90°CUT

MS200 PANELSHOWN

Eave to Gable Transition

EAVE TO GABLE TRANSITION

STEP 1

BEND UP 90°

CUT

REMOVE

BEND DOWN 90°CUT

MS200 PANELSHOWN

Page 35: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

32

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

TABBED EAVE

UNDERLAYMENT

HOOK EAVE

SUPPORTFLASHING

REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.

FASCIA BOARD,EAVE

FASCIA BOARD,RAKE

1"

PANCAKESCREW

STEP 2

TABBED EAVE

UNDERLAYMENT

HOOK EAVE

SUPPORTFLASHING

REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.

FASCIA BOARD,EAVE

FASCIA BOARD,RAKE

1"

PANCAKESCREW

Eave to Gable Transition

Page 36: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

33

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

NOTCH GABLEAROUND EAVE.

SUPPORTFLASHING

GABLE

FOLD PANELAROUNDHOOK EAVE.

CAP GABLEAND SEAL.

PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANELINSIDE CLOSURE.

PLACE FOLD AGAINSTHOOK EAVE FLASHING.

STEP 4

STEP 3

Eave to Gable Transition

NOTCH GABLEAROUND EAVE.

SUPPORTFLASHING

GABLE

FOLD PANELAROUNDHOOK EAVE.

CAP GABLEAND SEAL.

PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANELINSIDE CLOSURE.

PLACE FOLD AGAINSTHOOK EAVE FLASHING.

Page 37: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

34

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

SEAL

ROOFPANEL

UNDERLAYMENT

22 GA PLATEFASTENED TO DECK

BOTTOM OF RIVETNOTE: DO NOT PENETRATE PLATE.

SOLID SHANK WATERPROOF RIVET

FOR PIPES LOCATED GREATER THAN 20' FROM PIN POINT

SINGLE 22 GAUGE PLATE TWO OVERLAPPING 22 GAUGE PLATES

SS HOSE CLAMP

SEALANT

Pipe Penetration - on Plate

Allows panel and pipe flashing to move with temperature change.

Page 38: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

35Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

BUTYL TAPE

SCREW ZEE CLOSURE4" O.C. MINIMUM

1" TAB WITH FASTENER.FASTEN TO SEAM IF POSSIBLE.SEAL WITH CAULKING.

90° ANGLE TABON EXTERIOR, FASTENED

BUTYL TAPE

CUT HOLE IN PANELAT LEAST 1" LARGERTHAN PIPE

SEAL AROUND PIPE

SEALANT UP SIDESAND TOP OF SEAM

PRE-SEALBETWEEN SEAMS

Pipe Penetration - on Rib

Page 39: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

36

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

Pipe Penetration - on Rib

SET HOSE CLAMPAT TOP OF PIPE

BOOT AND SEAL WITHUV RESISTANT SEALANT

NEOPRENE WASHEREDSCREW 11

4" O.C. MINIMUM

PIPE BOOT

BEAD OF SEALANT

SEALANT

CUT HOLE 1"LARGER THAN PIPE

NEOPRENE WASHEREDSCREW 4" O.C. MINIMUM

12" DOWNTURN

ON CAP. ORHEM BACK OVER

ZEE CLOSUREOR FASTEN 4" O.C.

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

Page 40: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

37

Pipe Penetration - on PanTAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

SET HOSE CLAMP AT TOPOR USE UV RESISTANT SEALANT

NEOPRENE WASHEREDSCREW 11

4" O.C.

PIPE BOOT

2" MIN

BEAD OF SEALANT

CUT HOLE 1"LARGER THAN PIPE

AND SEAL WITHUNDERLAYMENT

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.

Page 41: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

38

TAYLORM E T A L P R O D U C T S

MS-200™ Installation Guide - 2020

338"

112"

SPECIFYPITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

438"

1"

112"

58" KICK,

12" HEM,

OPEN

SPECIFYPITCH

IF PAINTED,THIS SIDE

1"

12"

112"

12"

212"

438"

58"

12"

134"

438"

134"

58" KICK,

12" HEM,

OPEN

IF PAINTED,THIS SIDE1

2"12"

34"

1"

1"

314"

4"

512"

12" HEM,

OPEN

1"

12"

134"

12"

414"

1"

218"

3"

1"

12"1

2"

18"

151°

WEIGHT: 4.9 LBS.S.O. 6"SCALE 1:2

( MS200ES )EAVE STANDARD

WEIGHT: 6.5 LBS.S.O. 8"SCALE 1:2

( MS200EH )EAVE HOOK

WEIGHT: 2.5 LBS.S.O. 3"SCALE 1:2

( MS200OC )OFFSET CLEAT

WEIGHT: 13.3 LBS.S.O. 16"SCALE 1:3

( MS200BG )BOX GUTTER

WEIGHT: 7.6 LBS.S.O. 8.5"/9"SCALE 1:3

( MS200G )GABLE

WEIGHT: 7 LBS.S.O. 8.5"SCALE 1:3

( MS200AG )ALTERNATE GABLE

WEIGHT: 2.5 LBS.S.O. 3.25"SCALE 1:2

( MS200ALC )ALTERNATE L CLOSURE

WEIGHT: 4.7 LBS.S.O. 5.75"SCALE 1:3

( MS200GC )GABLE SUPPORT CLEAT

WEIGHT: 6 LBS.S.O. 6.125"/6.625"SCALE 1:3

( MS200SF )SUPPORT FLASHING

MS200 FlashingsMS200 are 10' Flashings

NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED

MS-200™ - FMFlashing and Details SelectionFlashing: 10' Standard

Page 42: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

39

TAYLORM E T A L P R O D U C T S

8"

112"

58"

12" HEM,

OPEN

SPECIFYPITCH

IF PAINTED,THIS SIDE

4X 120°

1"11"

SPECIFY PITCH

IF PAINTED,THIS SIDE

1"

1"

178"

7"

SPECIFY PITCH

IF PAINTED,THIS SIDE

12 " HEM,

OPEN

538"

7"SPECIFY

PITCH

IF PAINTED,THIS SIDE

1" HEM,OPEN

58" KICK,

12" HEM,

OPEN

1"

514"

12"

SPECIFYPITCH

6"

6"

58"

112"

12"

SPECIFY PITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

1614"

1"

SPECIFY PITCH

IF PAINTED,THIS SIDE

WEIGHT: 17.4 LBS.S.O. 21.25"SCALE 1:6

( MS200RFV )RIDGE FULL VENTED

SCALE 1:6 S.O. 24" WEIGHT: 19.7 LBS.

VALLEY FLASHING( MS200VF )

SCALE 1:3 S.O. 3.875" WEIGHT: 4.7 LBS.

ZEE CLOSURE( MS200ZF )

WEIGHT: 13.1 LBS.S.O. 15"SCALE 1:4

( MS200RS )STANDARD RIDGE

WEIGHT: 11.9 LBS.S.O. 14.5"SCALE 1:4

( MS200REC )PEAK FLASHING

WEIGHT: 6 LBS.S.O. 6.75"SCALE 1:3

( MS200RECC )PEAK CLEAT

WEIGHT: 12.9 LBS.S.O. 15.75"SCALE 1:4

( MS200RECV )VENTED PEAK FLASHING

MS200 FlashingsMS200 are 10' Flashings

VALLEY WIDE FLASHING( MS200FW )

SCALE 1:5

S.O. 34.5"

WEIGHT: 28.2 LBS.

MS-200™ Installation Guide - 2020

MS-200™ - FMFlashing and Details Selection

Flashing: 10' Standard

Page 43: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

MS-200™ - FMFlashing and Details SelectionFlashing: 10' Standard

40

TAYLORM E T A L P R O D U C T S

5"

6"

12"

4"

4"

12"11

2"1

2"

134"

414"

134"

12"

358"

1"

12"

5"

6"

12"

SPECIFY PITCH

12"

112"

58"

5"

438"

SPECIFY PITCH

1812"

512"

SPECIFY PITCH

SCALE 1:4 S.O. 11.5" WEIGHT: 9.8 LBS.

CURB ENDWALL( MS200CH )

SCALE 1:3 S.O. 5.625" WEIGHT: 4.6 LBS.

REGLET( MS200RF )

CURB SIDEWALL( MS200CSW )

SCALE 1:4 S.O. 10" WEIGHT: 8.2 LBS.

SIDEWALL( MS200SW )

SCALE 1:4 S.O. 8.75" WEIGHT: 10.3 LBS.

WEIGHT: 9.8 LBS.S.O. 11.5"SCALE 1:4

( MS200EW )ENDWALL

WEIGHT: 10.7 LBS.S.O. 12"SCALE 1:4

( MS200EWV )VENTED ENDWALL

MS200 FlashingsMS200 are 10' Flashings

WEIGHT: 21.3 LBS.

S.O. 24"

SCALE 1:4

( MS200PAN )BACK PAN

MS-200™ Installation Guide - 2020

Page 44: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

MS-200™ - FMFlashing and Details Selection

Flashing: 10' Standard

41

TAYLORM E T A L P R O D U C T S

4"

6"

1"

12"

12"

WEIGHT: VARIES

S.O. VARIES

END DAM

MS200 FlashingsMS200 are 10' Flashings

WEIGHT: 3.3 LBS.S.O. 4"SCALE 1:3

( MS200PS )PERFORATED STRIP

NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED

GUTTER HANGER( AGH6 )

SCALE 1:2

S.O. 8"

WEIGHT: 6.5 LBS.

MS-200™ Installation Guide - 2020

Page 45: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

Panels with * need Pattern Choice:□Ribs □Striations □Flat Notched? Y / N Clip Relief? Y / N Sealant? Y / N

Job Name: Ship To: □ Will Call Day:

Order Form □ New Order □ Add-on Order □ Quote

Inside Sale:

PO #: Date:

□ Delivery Delivery Date:

PBRMarion “R” Panel2-1/2" CorrugatedClassic 7/8" CorrugatedGR-7HR-34T-3Tuff-Rib

□□□□□□□□

12" Easy-Lock*16" Easy-Lock*16" StreamLine*12" CL-175*

□□ □□ □ □□□□

Color: Pitch: Gauge: Dmatch: Pallet: 10' 20' 30'

Panel & Flashing Items

Quantity Length Item Description Part # Quantity Length Item Description Part #

4566 Ridge Dr NE • Salem, OR 97301 • F: 503-581-6877 • P: 503-581-8338 • www.taylormetal.com

Forgetting Anything? Underlayment? Screws? Clips? Caulking? Closures?

TAYLORM E T A L P R O D U C T S

Sold To: Order Contact:Phone #:Fax #:

□ Agricultural □ Residential □ Commerical Route:

□□□

ShadowLine**(circle): 1", or 1-1/2" 1/2" to 3" Reveal:

1"x12-5/8" SmoothWall**1"x12-5/8" Lifetime Soffit**

Panels with ** need Pattern Choice: □Striations □Flat □1 V-Groove □2 V-GroovesPerforated?

12-3/8" Slim-Lock*16-1/4" Slim-Lock*12" MS-200*14-5/8" MS-200*16" MS-200*18" MS-200*12-3/4" MS-150*16-5/8" MS-150*20" MS-150*13-3/4" MS-100*17-5/8" MS-100*

□□□□□□□□□ □ □

12" Versa-Span*14-5/8" Versa-Span*16" Versa-Span*18" Versa-Span*15-1/2" T-Panel*

*All Kynar Slim-Lock, Easy-Lock, Lifetime Soffit, SmoothWall, ShadowLine, T-Panel, Versa-Span, CL-175, MS-100, MS-150, & MS-200 flashings are 10'*All ArmorTech StreamLine, T-3, Tuff Rib, GR7, PBR, HR-32, Marion "R", & Corrugated flashings are 12'6"

Flat not available on StreamLine

(Available on Lifetime Soffit Only)

( )Standard Panels are in Bold font.

Page 46: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

Custom Trim OrderTAYLORM E T A L P R O D U C T S

Please provide a drawing for each flashing with precise measurements and anglesFax to: 503-581-6877

4566 Ridge Dr NE Salem OR 97301 • Phone: 503-581-8338 or 1-800-574-1388 • www.taylormetal.com

Custom Trim OrderTAYLORM E T A L P R O D U C T S

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Please provide a drawing for each flashing with precise measurements and angles

www.taylormetal.com

Customer Name: Job Name:

Gauge: Color:

Page 47: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical
Page 48: METAL PRODUCTS MS-200™ Installation Guide · 2020. 11. 9. · manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical

TAYLORM E T A L P R O D U C T S

QUALITY PRODUCTSEXCEPTIONAL SERVICE

SALEM BRANCH4566 Ridge Dr. NESalem, OR 97301

Office: 503-581-8338Toll Free: 1-800-574-1388

Fax: 503-581-6877

WOODINVILLE BRANCH5927 234th St. SE

Woodinville, WA 98072

Office: 425-485-3003Toll Free: 855-334-8558

Fax: 425-485-2710

SACRAMENTO BRANCH5711 Perrin Ave

McClellan, CA 95652

Office: 916-318-8844Toll Free: 1-800-574-1388

Fax: 916-993-4123

AUBURN BRANCH710 A. St. NW Suite 101

Auburn, WA 98001

Office: 206-900-9923Toll Free: 1-800-574-1388

Fax: 253-804-3545

RIVERSIDE BRANCH4880 Felspar St.

Riverside, CA 92509

Office: 323-407-7457Toll Free: 1-877-504-1594

MS-200™ Installation Guide • ©2020 Taylor Metal Products

Revised 11/20