metal products slim-locktm installation guide · slim-lock™ standing seam taylor metal products 2...

40
Slim-Lock TM Installation Guide TAYLOR METAL PRODUCTS 12 3 8 " & 16 1 4 " 1 1 2 " 1" CLIP-LOCK 100 1 1 2" CLIP-LOCK 150

Upload: others

Post on 18-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Slim-LockTM Installation Guide

TAYLORM E T A L P R O D U C T S

1238" & 161

4"

112"

1" CLIP-LOCK 10011

2" CLIP-LOCK 150

Page 2: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"
Page 3: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Slim-Lock™Flashing and Details Guide

2-345

6-89

1011121314151617181920212223

24-2627

28-2930

31-34

35-36

Table of ContentsPanel Specifications ................................................................................. Taylor Delivery Fleet ....................................................................................Delivery & Will Call/Loading ........................................................................Notes To Designer/Installer ......................................................................Standard Eave ............................................................................................Hook Eave ................................................................................................... Gutter / Hook Eave .....................................................................................Standard Ridge ...........................................................................................Vented Ridge ............................................................................................... End Dam ....................................................................................................Valley ........................................................................................................... Valley – Low Pitch ....................................................................................... Standard Gable ........................................................................................... Alternate Gable ..........................................................................................Sidewall ...................................................................................................... Peak Flashing (R.E.C.) ..............................................................................Pitch Change .............................................................................................. Endwall .......................................................................................................Vented Endwall .......................................................................................... Eave to Gable Transition ......................................................................Pipe Penetration – on Plate .......................................................................Pipe Penetration – on Rib ..................................................................... Pipe Penetration – on Pan .........................................................................

Flashing Selection ................................................................................

Order Forms .........................................................................................

TAYLORM E T A L P R O D U C T S

1

Slim-Lock™ Installation Guide - 2020

Page 4: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Slim-Lock™STANDING SEAMTAYLOR

M E T A L P R O D U C T S

2

Slim-Lock™ Installation Guide - 2020

• Standard coverages: 12-3/8" & 16-1/4"

• 26, 24 & 22 gauge Tru-Gauge™ and .032" Aluminum

• 16 & 20 oz. Copper (Please inquire)

• Floating clip system: allows for expansion / conrtaction of panels in longer lengths

• 1-1/2" vertical rib

• Notching available

• Concealed fasteners: fasteners cannot leak

• UL 790 Class A Fire Rated

• 3:12 minimum pitch recommended (For lower pitches, please inquire)

• Standard panel lenghts 4' to 60' (For longer panels, please inquire)

• 1' Shortcut capability (Fee applicable)

• Onsite roll forming available

• Panel options: Striations, Accent Ribs, and Flat Pan

The Slim-Lock™ Standing Seam delivers a panel with strong, clean, continuous grace, together with unequaled quality. This provides you a weather tight roof to last a lifetime. Clip systems allow for extremely long panels, without the need for laps. STRIATIONS

ACCENT RIBS

12-3/8" & 16-1/4" coverage options

2 Accent ribs for 12-3/8" panel3 Accent ribs for 16-1/4" panel

PANEL PROFILES

SEAM DETAIL

KEY FEATURES

1" CLIP-LOCK 10011

2" CLIP-LOCK 1501-1/2"

Page 5: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

3

Slim-Lock™ Installation Guide - 2020

These printed chips provide a close representation of the colors. Metal samples are available upon request. Coatings are low gloss 10-15% sheen.SRI = Solar Reflective Index. SRI values listed above are in accordance with ASTM E 1980 and are based on actual testing.***Oil canning is not a cause for material rejection***

4-20

Kynar 500

Commercial-grade metal primer

G-90 galvanizing

24 or 26 guage steel

G-90 galvanizing

Commercial-grade metal primer

Corrosion resistant primer

Kynar 500® paint layer

Commercial-grade metal primerGalvanized G-90 or AZ-50

Base SteelGalvanized G-90 or AZ-50Commercial-grade metal primerCorrosion resistant wash coat

STANDARD COOL KYNAR 500® COLORS

MATERIAL SPECIFICATIONS• 26 gauge Kynar 500® Painted Steel .019" (Thickness prior to painting) Galvanized G-90 or AZ-50

• 24 gauge Kynar 500® Painted Steel .0236" (Thickness prior to painting) Galvanized G-90 or AZ-50

• 26, 24 & 22 gauge bare Zincalume® Plus AZ-55 (No finish warranty – 25 yr. perforation warranty)

• 22 gauge Kynar 500® Painted Steel .029" (Thickness prior to painting) Galvanized G-90 or AZ-50

• .032" Kynar 500® Painted Aluminum

• 16 and 20 ounce Copper (Please inquire)

• Kynar 500® and substrate testing data available (See website)

• “Oil Canning” is an inherent characteristic of roof and wall products, and not a defect, which is not a cause for panel rejection

KEY FEATURES• 21 Standard Colors, 5 Metallic Colors and 4 Specialized Colors

• Kynar 500® Paint System - the ultimate in exterior durability and color retention

• “Cool” color pigments are specially designed to reflect infrared light, reducing heat gain to dwelling, and conform with ENERGY STAR® criteria

• Superior quality, two coat, 70% resin finish, applied at a 1 mil. thickness

• 40 year residential paint warranty

• 20 and 30 year commercial paint warranty: Contact TMP for warranty specifications

Gla

cier

Whi

te S

RI-8

5

40-Year Residential / 20 and 30 Year Commercial Manufacturer’s Limited Warranty

Sier

ra T

an S

RI-6

0

Parc

hmen

t SR

I-58

Ster

ling

Gre

y SR

I-44

Zinc

Gre

y SR

I-39

Cha

rcoa

l Gre

y SR

I-25

Sadd

le T

an S

RI-3

7

Med

ium

Bro

nze

SRI-3

6

Mus

ket S

RI-3

1

Dar

k Br

onze

SR

I-27

Taho

e Bl

ue S

RI-3

1

Paci

fic B

lue

SRI-2

6

Hem

lock

Gre

en S

RI-3

6

Fore

st G

reen

SR

I-24

Pine

Gre

en S

RI-2

5

Burg

undy

SR

I-25

Terra

Cot

ta S

RI-4

3

Tile

Red

SR

I-35

Col

onia

l Red

SR

I-37

Blac

k SR

I-26

Met

allic

Silv

er S

RI-6

0

Cha

mpa

gne

SRI-4

8

Antiq

ue P

atin

a SR

I-40

Cop

per P

enny

SR

I-50

Wea

ther

ed Z

inc

SRI-3

9

16 o

z. a

nd 2

0 oz

. Cop

per

*ple

ase

inqu

ire* P

ure

copp

erha

s no

war

rant

y

Rus

teel

Plu

s™ (A

606)

Rus

teel

Plu

s™ h

as n

o m

etal

lic

coat

ing,

is u

npai

nted

and

has

no w

arra

nty

PREMIUM METALLIC COOL KYNAR® COLORS SPECIALIZED MATERIAL

✦ ✦ ✦ ✦ ✦

1,2,3 1,3 2 1,3 1,2,3 1,2,3 1,3 1,2,3 1,2,3

1,2 2,3 1,3 1,2,3 1,2,3 3 1,3 1

1,2,3

3 3 3 2,3 1,2,3 3

Ret

ro R

ed S

RI-4

2

Vint

age®

SR

I-19

Vint

age®

has

a c

olor

rang

e th

at

can

vary

from

bat

ch-to

-bat

ch.

See

TMP

web

site

for m

ore

info

Zinc

alum

e® P

lus

No

finis

h w

arra

nty

– 25

yr.

perfo

ratio

n w

arra

nty

3

Width Gauge Color LBSSQFT LBSLF12-3/8" 26 1 1.13 1.1312-3/8" 24 2 1.33 1.3316-1/4" 24 3 1.24 1.6516-1/4" 0.032 0.58 0.7816-1/4" 22 2.07 2.75

StandardPanelWeight

Page 6: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

4

TAYLORM E T A L P R O D U C T S

Taylor Delivery FleetDelivery FleetTaylor Metal Products prides itself with quick lead times delivered with our fleet of semi trucks. Our fleet of trucks are owned and operated by TMP. All of our drivers are Taylor Metal Products employees, so when your truck rolls in to deliver, you are dealing with Taylor Metal Products. Expect consistant and exceptional service with short lead times. The inhouse fleet allows for efficient and cost-effective delivery.

Mounted on the rear of our semitrailer, the trailer-mounted "piggy-back" forklift will accompany you right to your place of use, opening up unprecedented possibilities in terms of transportation. It can travel sideways, carrying panels up to 40' long, allowing delivery in locations that would typically be considered impossible to reach.Save time and effort while avoiding potential loading and transport issues; have experienced TMP personnel deliver and unload your order.

Slim-Lock™ Installation Guide - 2020

Page 7: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

TAYLORM E T A L P R O D U C T S

Delivery & Will Call/Loading

5

Will Call/LoadingFlatbed trailers and trucks are best suited to transport metal roofing materials. These can be loaded from the side with a forklift and tied down in a safe and secure manner.

We are not able to load materials onto vehicles and/or trailers which are not suitable or may be hazardous to load. Please be aware that if we find a vehicle to be inappropriate, we reserve the right to refuse to load your order.

Unacceptable examples include: boat trailers, vans, buses, motor homes, campers and box trailers. Pickup racks which do not have sufficient supports for the weight or are not long enough to support bundles are also unacceptable.

Taylor Metal Products is not responsible to tie down loads nor do we provide any tie down materials. Please bring tie downs to secure your load (string or twine are not acceptable for this purpose).

Consider having your order delivered on one of our trucks with a piggy back forklift.

DeliveryWe will make every attempt to deliver material to the desired location. We may be unable to gain access on tight corners or steep terrain. If the site is deemed inaccessible by our driver, the customer may choose an alternate delivery site within a reasonable proximity. If we are unable to make the alternate delivery, additional charges may be assessed.

The customer is responsible for:• Determining adequate access for delivery

ahead of time.• Meeting the delivery at the agreed upon

time.• Providing adequate resources

(1-4 people as needed) for off loading materials.

• A charge of $100 per hour may be added for deliveries that go beyond their allotted time

• Check the shipment at the time of delivery.• Verify material quantities against the

shipping/packing list.• Note any damage or discrepancies upon

the paper work at the time of delivery and notify Taylor Metal Products within 48 hours of delivery.

Delivery times are usually scheduled one day in advance. Taylor Metal Products will make every effort to make the delivery at the scheduled time. Please be aware that there may be conditions beyond our control such as traffic, mechanical failures, road closures, etc. which may affect our schedule.

Slim-Lock™ Installation Guide - 2020

Page 8: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Notes to Designer/Installer

Taylor Metal Products is providing the following details as an aid in design. The details in this guide are not inclusive to all design situations. The designer/installer is responsible for modifications and should take into consideration all aspects of the project including climate conditions, such as, snow and wind, as well as, building code requirements, building design, building usage and maintenance requirements.

Installation should be performed only by qualified installers familiar with metal roofing systems and industry standards. For details not shown in this guide, refer to the Sheet Metal and Air Conditioning Contractors National Association (SMACNA) architectural sheet metal manual for proper design. For manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical representative.

The Standard gauge for all products in this guide is 24 gauge and the standard finish is Kynar 500®. We recommend specifying all flashings be the same gauge, color, and finish as the panels to insure long-term durability and color match.

SubstratesDetails in the manual are all shown over solid substrate. Slim-Lock™ can be used over spaced purlins. For solid substrate, Taylor Metal Products recommends 5/8" plywood or metal decking.

UnderlaymentMinimum underlayment requirements are 30 lb. ASTM rated felt, a synthetic underlayment with Class A and ASTM UV protection technology or a high temperature self-adhering rubberized membrane. When choosing the underlayment, consider the roof slope, roof design, roof panel, and the climate.

Drag Load RequirementsAll panels must be pinned at one end to resist the drag load caused by snow loads, live loads, and the weight of the panel. Drag load is a function of roof slope, actual load and length of panels. Contact Taylor Metal Products for specific drag load requirements.

6

Slim-Lock™Flashing and Details Guide

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

Page 9: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Ventilation/InsulationIt is the responsibility of the designer to determine the material types needed to control condensation and to insulate and ventilate the roof system. Applications over rigid insulation may require blocking for solid attachment and framing the perimeter for installation of perimeter flashings.

Oil CanningFlat metal surfaces will display waviness commonly referred to as “oil canning.” Oil canning is caused by a variety of conditions. Steel mill tolerances, variations in or uneven substrates and roofing underlayments. Oil canning is a characteristic of metal roofing, not a defect and is not a cause for rejection. Taylor Metal Products offers Slim-Lock™ with striations or accent ribs to help minimize oil canning.

Thermal MovementThe Panels and the flashings must be allowed to expand and contract, especially with longer length panels. The panel may need to have a slight gap where the panel hooks the offset cleat to allow for thermal movement of the panels.

Snow DesignThe following details do not address all conditions for snow environments. Consult with the designers, engineers, and others for acceptable details to accommodate your project and climate conditions. When possible gutters, valleys, pitch changes or other penetrations should be minimized in snow areas.

All roof penetrations should be located as close to the ridge or “pin point” top of roof. Snow country requires special designs for valleys to accommodate accumulation of snow and ice from uphill panels. Roof design should be considered in snow areas. Roof design should help resist the melting and freezing of snow and ice.

A fit for purpose roof design has the greatest impact on maintaining a damage free roof system in snow areas. Please contact a Taylor Metal Products representative for assistance in detail designs and appropriate panel selection for specific climate and building conditions.

7

Slim-Lock™Flashing and Details Guide

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

Page 10: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Handling / Storage & SafetyHandle materials with care when off-loading or moving materials to avoid damage to panels or flashings. Long panels may require two or more pick-up points, properly spaced to avoid damaging panels. Plan ahead; contact Taylor Metal Products for recommendations on handling/hoisting long panels.

Store the panels, flashings and accessories in a dry, well ventilated area, off the ground. If covering, allow ventilation around panels. Elevate one end of bundle to allow drainage of wet materials.

Wear clean, soft-soled shoes when walking on roofing panels to avoid damage to the painted finish.

Take care that sand, gravel, dirt, etc. sticking to your shoes is not carried onto the roof, scratching or otherwise damaging the finish on the roofing material. Walking on asphalt impregnated felt paper, especially on a hot day, can cause the asphalt to stick to your shoes and be tracked on to the roofing material.

Take care when painting to avoid getting over spray on the roofing material. Remember that wind can carry paint particles some distance. Over spray can cause the finish of the roofing material to look dull and may void your warranty.

Secure materials, especially when leaving the site, on the ground or roof to prevent winds from moving the materials. Wind-blown materials may cause damage to the material, property or persons.

Always use proper safety equipment and attire to minimize risk of cuts or other injuries.

Do not walk on panels that have not been completely installed.

Do not walk on major ribs of panels.

Metal roofs that are wet or dusty can be extremely slippery. Wear soft soled shoes and a safety harness to minimize risk of falling.

Avoid installing metal panels in windy conditions.

Safety considerations are the responsibility of the installer and his crew. Be sure to and use common sense generally accepted safety practices when installing roofing materials.

8

Slim-Lock™Flashing and Details Guide

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

Page 11: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Standard Eave

9

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

338"

112"

SPECIFYPITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPENSCREW 8" O.C.

UNDERLAYMENTOVER SCREW

DOUBLE ROW OFSEALANT

9" STRIP OFUNDERLAYMENT

STANDARD EAVE

OFFSET CLEAT

SEALANT

SLIM-LOCK PANEL

FASCIA

SHEATHINGBEND NOTCHED PANELOVER CLEAT. LEAVE SPACE

FOR PANEL EXPANSIONAND CONTRACTION

SEALANT 8"FROM EAVE

SHEATHING

EAVE

9" UNDERLAYMENT STRIP

FASCIA BOARD

SLIM-LOCKPANEL

UNDERLAYMENT

FIRST CLIP12" FROM EAVE

2" GAPIN SEALANT

SEALANT

SCREW EAVEUNDER PANEL

2- PAN/WAFERHEAD PER CLIP

SEALANT REQUIRED UNDERFLAT AS SHOWN IN WET

ENVIRONMENTS ONLY(COASTAL / MARINE AND

WEST CASCADE MTNS)

OFFSET CLEAT

SCREW 8" O.C.

Slim-Lock FlashingsFlashing and Details GuideEave / Hook Eave

STANDARD EAVE DETAIL

STANDARD EAVE(SMES)

Page 12: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

10

Hook Eave TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

2- PAN/WAFER HEADHEAD PER CLIP

SHEATHING

EAVE

9" UNDERLAYMENT STRIP

FASCIA BOARD

SLIM-LOCKPANEL

UNDERLAYMENT

FIRST CLIP12" FROM EAVE

SEALANT

SCREW EAVEUNDER PANEL

SEALANT REQUIRED UNDERFLAT AS SHOWN IN WET

ENVIRONMENTS ONLY(COASTAL / MARINE AND

WEST CASCADE MTNS)

SCREW 8" O.C.2" GAP

IN SEALANT

438"

1"

112"

SPECIFYPITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

HOOK EAVE

SCREW

UNDERLAYMENTOVER SCREW

DOUBLE ROW OFSEALANT

9" STRIP OFUNDERLAYMENT

SLIM-LOCK PANEL

FASCIA

SHEATHINGBEND NOTCHED PANELOVER HOOK. LEAVE SPACE

FOR PANEL EXPANSIONAND CONTRACTION

SEALANT 8"FROM EAVE

HOOK EAVE DETAILHOOK EAVE

(SMEH)

Slim-Lock FlashingsSlim-Lock are 10' FlashingsHook Eave

Page 13: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

11

Gutter / Hook Eave

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

SCREW 8" O.C.

LAP UNDERLAYMENTOVER SCREW

DOUBLE ROW OF SEALANT

9" STRIP UNDERLAYMENTUNDER EAVE

HOOK EAVE

GUTTER HANGER

BOXGUTTER

NEOPRENE WASHEREDSCREW.

GUTTER TAPEREDTO DOWNSPOUT

SLIM-LOCK PANEL

FASCIA

SHEATHING

SEALANT 8"FROM EAVE

34"

1"

1" 314"

4"

512"

12" HEM,

OPEN

6"

2- PAN/WAFER HEADSCREWS PER CLIP

SHEATHING

EAVE

9" UNDERLAYMENT STRIP

FASCIA BOARD

SLIM-LOCKPANEL

UNDERLAYMENT

FIRST CLIP12" FROM EAVE

2" GAPIN SEALANT

SEALANT

SCREW EAVEUNDER PANEL

GUTTER HANGER

BOX GUTTER

SEALANT REQUIRED UNDER FLATAS SHOWN IN WET

ENVIRONMENTS ONLY(COASTAL / MARINE AND

WEST CASCADE MTNS)

438"

1"

112"

SPECIFYPITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

HOOK EAVE WITHGUTTER DETAIL

Slim-Lock Flashings

BOX GUTTER(SMBG)

BOX GUTTER HANGER(AGH6)

Flashing and Details GuideGutter Eave

HOOK EAVE(SMEH)

Page 14: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

12

Standard Ridge

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

4" LAP

4"

1" BUTYL SPACING

SLIM-LOCKPANEL

STANDARD RIDGE

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

INTO EACH END DAM(AVOID STANDING SEAMS)

SHEATHING

UNDERLAYMENT

NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE

SEALANT

SCREW END DAMTO SEAM

SPECIFY PITCH

IF PAINTED,THIS SIDE

12 " HEM,

OPEN

STANDARD RIDGE DETAIL

Slim-Lock FlashingsFlashing and Details GuideStandard Ridge

STANDARD RIDGE(SMRS)

STANDARD RIDGE LAP

Page 15: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

13

Vented Ridge

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

3 ROWS OF SEALANT

NEOPRENE WASHEREDSCREW 4" O.C.

1"

4" LAP

SHEATHING

SLIM-LOCKPANEL

SEALANT

SCREW END DAMTO SEAM

UNDERLAYMENT

VENTED RIDGE

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

TEK SCREW INTOEACH PANEL RIB

4" PERFORATEDSTRIP

NEOPRENE WASHERED SCREWOR RIVET AT 12" O.C. INTO EACH

END DAM. (AVOID STANDING SEAMS)

SEALANTON TAB

SEALANT

8"

112"

58"

12" HEM,

OPEN

SPECIFYPITCH

IF PAINTED,THIS SIDE

4X 120°

Slim-Lock FlashingsFlashing and Details GuideStandard Ridge

VENTED RIDGE DETAIL

RIDGE FULL VENTED(SMRFV)

VENTED RIDGE LAP

Page 16: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

14

End Dam Attachment

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

SEALANT ON TOP OFRIB TO FILL GAPS

AFTER END DAM IS INSTALLED,FILL ALL VOIDS ON FRONT SIDEOF END DAM WITH GUNNABLE SEALANT.

SEALANT

SCREW ENDDAM TO PANEL

NEOPRENE WASHERSCREW 1" FROM RIB.4" O.C. MAY BE REQUIREDDEPENDING ON DRAG LOADREQUIREMENTS.

APPLY SEALANT ONBOTTOM AND SIDES

OF END DAM.

SCREW END DAMTO PANEL RIB

END DAMEND DAM

SCREW END DAMTO PANEL RIB

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIBAND 4" O.C. MINIMUM, DRAGLOAD CALCULATIONS MAYREQUIRE MORE.

SHEATHING UNDERLAYMENT

SLIM-LOCKPANEL

SEALANT

END DAM ATTACHMENT APPLICATION

Slim-Lock FlashingsFlashing and Details GuideEnd Dam Attachment

Page 17: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

15

Valley FlashingSlope3:12 or Greater

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

1"11"

SPECIFY PITCHIF PAINTED,THIS SIDE

1"

12"

112"

150° TYP.

THREE ROWS OFSEALANT AT LAP JOINT

6" LAP

1"

FIRST CLIP 12"FROM VALLEY

OFFSET CLEAT

SEALANT

DOUBLE ROW OFSEALANT

LAP UNDERLAYMENTOVER SCREW

UNDERLAYMENT

PAN/WAFER HEAD2 PER CLIP

SEALANT 8"FROM EAVE

FASTEN OFFSET CLEAT 8" O.C.

SHEATHING

4" MIN.

Slim-Lock FlashingsFlashing and Details GuideValley - 3:12 or Greater

VALLEY 24" FLASHING(SMVF)

OFFSET CLEAT(SMOC)

VALLEY 24" DETAIL(3:12 Or Greater Pitch)

VALLEY LAP(3:12 Or Greater Pitch)

Page 18: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

16

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

SEALANT

NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.

TRIPLE ROW OF CAULK

UNDERLAYMENT

SEALANT 8"FROM EAVE

SHEATHING

4" MIN.

IF PAINTED,THIS SIDE

1"

11"

SPECIFY PITCH

THREE ROWS OFCAULK

12"

Slim-Lock FlashingsFlashing and Details GuideValley Flashing - Recommended Application Less than 3:12 Slope

VALLEY FLASHING(SMVF)

LOW SLOPE VALLEY DETAIL(Less Than 3:12 Slope Pitch - Not Recommended)

LOW SLOPE VALLEY LAP(Less Than 3:12 Slope Pitch - Not Recommended)

Valley Flashing - Low PitchSlope Less than 3:12

Page 19: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

17

Standard Gable

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

134"

438"

114"

58" KICK,

12" HEM,

OPEN

IF PAINTED,THIS SIDE

12"

NEOPRENE WASHERED SCREWOR RIVET 12" O.C.

SCREW 8" O.C.WITH SEALANTOVER THE TOP

UNDERLAYMENTDOWN FACE 3" MINIMUM

SEALANT

SUPPORT FLASHINGBEND PANEL 90°

STANDARD GABLE

SHEATHING

FASCIA 158"

3"

1"

12"

12"

18"151°

UNDERLAYMENT

SHEATHING

FASCIA

SUPPORT FLASHINGSCREW WITHSEALANT OVERTHE TOP

SLIM-LOCKPANEL

BEND PANEL 90°

NEOPRENE WASHEREDSCREW OR RIVET

STANDARD GABLE

SEALANT

STANDARD GABLE DETAIL STANDARD GABLE(SMGS)

SUPPORT FLASHING(SMSF)

Slim-Lock FlashingsFlashing and Details GuideStandard Gable

Page 20: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

TAYLORM E T A L P R O D U C T S

Alternate Gable

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

18

Slim-Lock™ Installation Guide - 2020

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

SEALANT

SUPPORT FLASHING

SCREW 8" O.C. WITHSEALANT OVER TOP

CLEAT SCREW12" O.C.

UPEND PANEL2" AT 90°

ALT. GABLE

SHEATHING

FASCIA

UNDERLAYMENTWRAPPED DOWNFACE 2"

SEALANT

CONTINUOUS CLEAT

ALT. L CLOSURE

12"

212"

438"

58" KICK,

12" HEM,

OPEN

12"

414"

1"

158"

3"

1"

12"

12"

18" 151°

1"

12"

114"

ALTERNATE GABLE DETAIL

ALTERNATE L CLOSURE(SMALC)

SUPPORT FLASHING(SMSF)

ALTERNATE GABLE(SMGA)

GABLE SUPPORT CLEAT(SMGC)

Slim-Lock FlashingsFlashing and Details GuideAlternate Gable

Page 21: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

19Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

IF PAINTED,THIS SIDE41

2"

134"

114"

12" HEM,

LAP UNDERLAYMENTOVER SCREW

UNDERLAYMENTTURN UP WALL 8"

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

SCREW 8" O.C. WITHSEALANT OVER THE TOP

SUPPORTFLASHING

BEND PANELEDGE AT 90°

SEALANT

WALL PANEL/SIDING

SHEATHING

SIDEWALL

SLIM-LOCK PANEL

158"

3"

1"

12"

12"

18" 151°

SHEATHING

WALL PANELLAP UNDERLAYMENT

OVER SCREW

SEALANT

SUPPORTFLASHING

SLIM-LOCKPANEL

SIDEWALL

UNDERLAYMENTTURN UP WALL 8"

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

BEND PANEL 90°

SCREW 8" O.C. WITHSEALANT OVER THE TOP

Slim-Lock FlashingsFlashing and Details GuideSidewall

SIDEWALL DETAIL SIDEWALL(SMSW)

SUPPORT FLASHING(SMSF)

Sidewall

Page 22: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

20

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

4" LAP 1"

4"

LAP 4" WITH 3 ROWSSEALANT

SLIM-LOCKPANEL

PEAK FLASHING

NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.

INTO EACH END DAM(AVOID STANDING SEAMS)

SHEATHING

UNDERLAYMENT

NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE

SEALANT

538"

7"SPECIFY

PITCH

IF PAINTED,THIS SIDE

1" HEM,OPEN

5 " KICK,

1"

514"

12"

SPECIFYPITCH

Slim-Lock FlashingsFlashing and Details GuidePeak Flashing

PEAK FLASHING DETAIL(Ridge End Cap)

PEAK FLASHING (Ridge End Cap)(SMREC)

PEAK CLEAT(SMRECC)

PEAK FLASHING LAP

Peak Flashing (Ridge End Cap)

Page 23: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

21

Pitch Change

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

4" LAP1" GAP

THREE ROWS SEALANT AT LAP JOINT

4"

FASTEN EVERY12" INTO END DAM(AVOID STANDING SEAMS)

TWO ROWS SEALANT

SHEATHING

LAP UNDERLAYMENTOVER SCREW

SLIM-LOCK PANEL

PITCH CHANGE FLASHING

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND

4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

FOLD PANEL END 180°,HOOK OVER OFFSET CLEAT

OFFSET CLEAT

FASTEN 8" O.C.

SPECIFY PITCH

IF PAINTED,THIS SIDE

4"

6"

12"

1"

12"

112"

Slim-Lock FlashingsFlashing and Details GuideInside Pitch Change

PITCH CHANGE DETAIL

INSIDE PITCH CHANGE FLASHING

PITCH CHANGE LAP

OFFSET CLEAT(SMOC)

Page 24: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

22

Endwall

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

SLIM-LOCKPANEL

WALL PANEL

END DAM

ENDWALL

5"

6"

IF PAINTED,THIS SIDE

SPECIFY PITCH

LAP UNDERLAYMENTOVER SCREW

UNDERLAYMENT

NEOPRENE WASHERED SCREWOR RIVET AT 12" O.C. (AVOIDSTANDING SEAMS)

WALL PANEL

SLIM-LOCK PANEL

ENDWALL

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

SHEATHING

Slim-Lock FlashingsFlashing and Details GuideHemmed EndWall

ENDWALL DETAIL

ENDWALL FLASHING(SMEW)

Page 25: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

23

Vented Endwall

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

438"

5"

58"

112"

SPECIFYPITCH

2X 135°

IF PAINTED,THIS SIDE

12" HEM,

OPEN

WALLPANEL

TEK SCREWEACH PANEL RIB

NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.

SEALANT

NEOPRENE WASHEREDSCREW OR RIVET AT 12"

O.C. INTO EACH END DAM.

FASTEN 12" O.C.INTO EACH END DAM

(AVOID STANDING SEAMS)

4" PERFORATEDSTRIP

UNDERLAYMENT

UNDERLAYMENTOVER SCREW

SHEATHING

3 ROWS OF SEALANTAT LAP JOINT

4" LAP1"

NEOPRENEWASHERED

SCREW

VENTED ENDWALL DETAIL VENTED ENDWALL FLASHING(SMEWV)

Slim-Lock FlashingsFlashing and Details GuideVented EndWall

ENDWALL LAP

Page 26: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

24

Eave to Gable Transition

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

BEND UP 90°

CUT

REMOVE

BEND DOWN 90°CUT

SLIM-LOCK PANELSHOWN

Slim-Lock FlashingsFlashing and Details GuideEave to Gable Transition Application

EAVE TO GABLE TRANSITION APPLICATION

STEP 1

Page 27: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

25

Eave to Gable Transition

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

TABBED EAVE

UNDERLAYMENT

HOOK EAVE

SUPPORTFLASHING

REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.

FASCIA BOARD,EAVE

FASCIA BOARD,RAKE

1"

PANCAKESCREW

Slim-Lock FlashingsFlashing and Details GuideEave to Gable Transition Application

STEP 2

Page 28: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

26

Eave to Gable Transition

Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

NOTCH GABLEAROUND EAVE.

SUPPORTFLASHING

GABLE

FOLD PANELAROUNDHOOK EAVE.

CAP GABLEAND SEAL.

PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANEL

INSIDE CLOSURE.

PLACE FOLD AGAINSTHOOK EAVE FLASHING.

Slim-Lock FlashingsFlashing and Details GuideEave to Gable Transition Application

STEP 4

STEP 3

Page 29: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

27

Pipe Penetration - on PlateTAYLORM E T A L P R O D U C T S

SEAL

ROOFPANEL

UNDERLAYMENT

22 GA PLATEFASTENED TO DECK

BOTTOM OF RIVETNOTE: DO NOT PENETRATE PLATE.

SOLID SHANK WATERPROOF RIVET

FOR PIPES LOCATED OVER 20' FROM PIN POINT

(Allows panel and pipe flashing to move with temperature change.)

SINGLE 22 GAUGE PLATE TWO OVERLAPPING 22 GAUGE PLATES

SS HOSE CLAMP

SEALANT

Page 30: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

BUTYL TAPE

SCREW ZEE CLOSURE4" O.C. MINIMUM

90° ANGLE TABON EXTERIOR, FASTENED

1" TAB WITH FASTENER.FASTEN TO SEAM IF POSSIBLE.SEAL WITH CAULKING.

BUTYL TAPE

SEAL AROUND PIPE

SEALANT UP SIDESAND TOP OF SEAM

CUT HOLE IN PANELAT LEAST 1" LARGERTHAN PIPE

PRE-SEALBETWEEN SEAMS

28

Pipe Penetration - on Rib TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

STEP 2

STEP 1

Page 31: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

29

Pipe Penetration - on RibTAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

STEP 4

STEP 3

SET HOSE CLAMPAT TOP OF PIPE

BOOT AND SEAL WITHUV RESISTANT SEALANT

NEOPRENE WASHEREDSCREW 11

4" O.C. MINIMUM

PIPE BOOT

BEAD OF SEALANT

SEALANT

CUT HOLE 1"LARGER THAN PIPE

NEOPRENE WASHEREDSCREW 4" O.C. MINIMUM

12" DOWNTURN

ON CAP. ORHEM BACK OVER

ZEE CLOSUREOR FASTEN 4" O.C.

Page 32: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

30

Pipe Penetration - on Pan TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

Note: Allow a minimun of 2" between the base of the pipe flashing and the standing seam.

SET HOSE CLAMP AT TOPOR USE UV RESISTANT SEALANT

NEOPRENE WASHEREDSCREW 11

4" O.C.

PIPE BOOT

2" MIN

BEAD OF SEALANT

CUT HOLE 1"LARGER THAN PIPE

AND SEAL WITHUNDERLAYMENT

Page 33: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Slim-Lock™ Flashing and Details Selection

Flashing: 10' Standard

31

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

338"

112"

SPECIFYPITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

438"

1"

112"

SPECIFYPITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

1"

12"

112"

12"

212"

438"

58" KICK,

12" HEM,

OPEN

134"

438"

114"

58" KICK,

12" HEM,

OPEN

IF PAINTED,THIS SIDE

12"

34"

1"

1"

314"

4"

512"

12" HEM,

OPEN

6"

1"

12"

114"

12"

414"

1"

158"

3"

1"

12"

12"

18"151°

WEIGHT: 4.9 LBS.S.O. 6"SCALE 1:2

( SMES )EAVE STANDARD

WEIGHT: 6.5 LBS.S.O. 8"SCALE 1:2

( SMEH )EAVE HOOK

WEIGHT: 2.5 LBS.S.O. 3"SCALE 1:2

( SMOC )OFFSET CLEAT

WEIGHT: 13.3 LBS.S.O. 16"SCALE 1:3

( SMBG )BOX GUTTER

WEIGHT: 7.6 LBS.S.O. 8.5"/9"SCALE 1:3

( SMGS )STANDARD GABLE

WEIGHT: 7 LBS.S.O. 8.5"SCALE 1:3

( SMGA )ALTERNATE GABLE

WEIGHT: 2.5 LBS.S.O. 2.25"/2.75"SCALE 1:2

( SMALC )ALTERNATE L CLOSURE

WEIGHT: 4.7 LBS.S.O. 5.75"SCALE 1:3

( SMGC )GABLE SUPPORT CLEAT

WEIGHT: 6 LBS.S.O. 6.125"/6.625"SCALE 1:3

( SMSF )SUPPORT FLASHING

Slim-Lock FlashingsSlim-Lock are 10' Flashings

NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED

Page 34: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Slim-Lock™ Flashing and Details SelectionFlashing: 10' Standard

32

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

8"

112"

58"

12" HEM,

OPEN

SPECIFYPITCH

IF PAINTED,THIS SIDE

4X 120°

1"11"

SPECIFY PITCHIF PAINTED,THIS SIDE

1"

1"

112"

7"

SPECIFY PITCH

IF PAINTED,THIS SIDE

12 " HEM,

OPEN

538"

7"SPECIFY

PITCH

IF PAINTED,THIS SIDE

1" HEM,OPEN

58" KICK,

12" HEM,

OPEN

1"

514"

12"

SPECIFYPITCH

6"

6"

58"11

2"

12"

SPECIFY PITCH

IF PAINTED,THIS SIDE

58" KICK,

12" HEM,

OPEN

1614"

1"1"

1614"

SPECIFY PITCH

IF PAINTED,THIS SIDE

WEIGHT: 17.4 LBS.S.O. 21.25"SCALE 1:6

( SMRFV )RIDGE FULL VENTED

SCALE 1:6 S.O. 24" WEIGHT: 19.7 LBS.

VALLEY FLASHING( SMVF )

SCALE 1:3 S.O. 3"/3.5" WEIGHT: 3 LBS.

ZEE CLOSURE( SMZC )

WEIGHT: 13.1 LBS.S.O. 15"SCALE 1:4

( SMRS )STANDARD RIDGE

WEIGHT: 11.9 LBS.S.O. 14.5"SCALE 1:4

( SMREC )PEAK FLASHING (RIDGE END CAP)

WEIGHT: 6 LBS.S.O. 6.75"SCALE 1:3

( SMRECC )PEAK CLEAT

WEIGHT: 12.9 LBS.S.O. 15.75"SCALE 1:4

( SMRECV )VENTED PEAK FLASHING (REC)

Slim-Lock FlashingsSlim-Lock are 10' Flashings

VALLEY WIDE FLASHING( SMVFW )

SCALE 1:5

S.O. 34.5"

WEIGHT: 28.2 LBS.

Page 35: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Slim-Lock™ Flashing and Details Selection

Flashing: 10' Standard

33

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

5"

6"

12"

4"

4"

12"

114"

12"

134"

414"

114"

12"

358"

1"

12"

5"

6"

12"

SPECIFY PITCH

12"

112"

58"

5"

438"

SPECIFY PITCH

1812"

512"

SPECIFY PITCH

SCALE 1:4 S.O. 11.5" WEIGHT: 9.8 LBS.

CURB ENDWALL( SMCH )

SCALE 1:3 S.O. 5.625" WEIGHT: 4.6 LBS.

REGLET( SMRF )

CURB SIDEWALL( SMCSW )

SCALE 1:4 S.O. 9.25" / 9.75" WEIGHT: 8.2 LBS.

SIDEWALL( SMSW )

SCALE 1:4 S.O. 7.25" / 7.75" WEIGHT: 6.6 LBS.

WEIGHT: 9.8 LBS.S.O. 11.5"SCALE 1:4

( SMEW )ENDWALL

WEIGHT: 10.7 LBS.S.O. 12"SCALE 1:4

( SMEWV )VENTED ENDWALL

Slim-Lock FlashingsSlim-Lock are 10' Flashings

WEIGHT: 21.3 LBS.

S.O. 24"

SCALE 1:4

( SMPAN )BACK PAN

Page 36: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Slim-Lock™ Flashing and Details SelectionFlashing: 10' Standard

34

TAYLORM E T A L P R O D U C T S

Slim-Lock™ Installation Guide - 2020

4"

6"

1"

12"

12"

WEIGHT: VARIES

S.O. VARIES

END DAM

Slim-Lock FlashingsSlim-Lock are 10' Flashings

WEIGHT: 3.3 LBS.S.O. 4"SCALE 1:3

( SMPS )PERFORATED STRIP

NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED

GUTTER HANGER( AGH6 )

SCALE 1:2

S.O. 8"

WEIGHT: 6.5 LBS.

Page 37: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Panels with * need Pattern Choice:□Ribs □Striations □Flat Notched? Y / N Clip Relief? Y / N Sealant? Y / N

( )

Job Name: Ship To: □ Will Call Day:

Order Form □ New Order □ Add-on Order □ Quote

Inside Sale:

PO #: Date:

□ Delivery Delivery Date:

PBRMarion “R” Panel2-1/2" CorrugatedClassic 7/8" CorrugatedGR-7HR-34T-3Tuff-Rib

□□□□□□□□

12" Easy-Lock*16" Easy-Lock*16" StreamLine*12" CL-175*

□□ □□ □ □□□□

Color: Pitch: Gauge: Dmatch: Pallet: 10' 20' 30'

Panel & Flashing Items

Quantity Length Item Description Part # Quantity Length Item Description Part #

4566 Ridge Dr NE • Salem, OR 97301 • F: 503-581-6877 • P: 503-581-8338 • www.taylormetal.com

Forgetting Anything? Underlayment? Screws? Clips? Caulking? Closures?

TAYLORM E T A L P R O D U C T S

Sold To: Order Contact:Phone #:Fax #:

□ Agricultural □ Residential □ Commerical Route:

□□□

ShadowLine**(circle): 1", or 1-1/2" 1/2" to 3" Reveal:

1"x12-5/8" SmoothWall**1"x12-5/8" Lifetime Soffit**

Panels with ** need Pattern Choice: □Striations □Flat □1 V-Groove □2 V-GroovesPerforated? Y / N (Available on Flat only)

12-3/8" Slim-Lock*16-1/4" Slim-Lock*12" MS-200*14-5/8" MS-200*16" MS-200*18" MS-200*12-3/4" MS-150*16-5/8" MS-150*20" MS-150*13-3/4" MS-100*17-5/8" MS-100*

□□□□□□□□□ □ □

12" Versa-Span*14-5/8" Versa-Span*16" Versa-Span*18" Versa-Span*15-1/2" T-Panel*

*All Kynar Slim-Lock, Easy-Lock, Lifetime Soffit, SmoothWall, ShadowLine, T-Panel, Versa-Span, CL-175, MS-100, MS-150, & MS-200 flashings are 10'*All ArmorTech StreamLine, T-3, Tuff Rib, GR7, PBR, HR-32, Marion "R", & Corrugated flashings are 12'6"

Flat not available on StreamLine

Standard Panels are in Bold font.

Page 38: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

Please provide a drawing for each flashing with precise measurements and anglesFax to: 503-581-6877

4566 Ridge Dr NE Salem OR 97301 • Phone: 503-581-8338 or 1-800-574-1388 • www.taylormetal.com

Custom Trim OrderTAYLORM E T A L P R O D U C T S

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Drawing #:___ Pitch: _____ # of Pieces: ______________

Description: _____________________________________

Hems: □ Open □ Closed □ Slightly Open

Please provide a drawing for each flashing with precise measurements and angles

www.taylormetal.com

Customer Name: Job Name:

Gauge: Color:

Custom Trim OrderTAYLORM E T A L P R O D U C T S

Page 39: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"
Page 40: METAL PRODUCTS Slim-LockTM Installation Guide · Slim-Lock™ STANDING SEAM TAYLOR METAL PRODUCTS 2 Slim-Lock™ Installation Guide - 2020 • Standard coverages: 12-3/8" & 16-1/4"

TAYLORM E T A L P R O D U C T S

QUALITY PRODUCTSEXCEPTIONAL SERVICE

SALEM BRANCH4566 Ridge Dr. NESalem, OR 97301

Office: 503-581-8338Toll Free: 1-800-574-1388

Fax: 503-581-6877

WOODINVILLE BRANCH5927 234th St. SE

Woodinville, WA 98072

Office: 425-485-3003Toll Free: 855-334-8558

Fax: 425-485-2710

SACRAMENTO BRANCH5711 Perrin Ave

McClellan, CA 95652

Office: 916-318-8844Toll Free: 1-800-574-1388

Fax: 916-993-4123

AUBURN BRANCH710 A. St. NW Suite 101

Auburn, WA 98001

Office: 206-900-9923Toll Free: 1-800-574-1388

Fax: 253-804-3545

RIVERSIDE BRANCH4880 Felspar St.

Riverside, CA 92509

Office: 323-407-7457Toll Free: 1-877-504-1594

Slim-Lock™ Installation Guide • ©2020 Taylor Metal ProductsRevised 4/20