MethanolInjection.xlsThis spreadsheet calculates the minimum amount of required inhibotor usage.
Input Data:
Gas flow rate: 10 MMscfd
0.7 air = 1
900 psia
90
64
40
48 lb/MMscf
9.6 lb/MMscfInhibitor solution density: 6.64 ppg
100 Wt %
Intermediate Calculations:
38.4 lb/MMscf
32
2335
24Inhibitor requirement based on Hammerschmidt's method:
= 24.75 Wt %
Liquid phase:
= 12.63 lb/MMscf
Gas phase:
= 1.05
Inhibitor requirement: 25.99 lb/MMscf
System total:
Gas specific gravity (gg):
Minimum pressure (pm):
Inlet gas temperature (ti): oF
Hydrate temperature pm: oF
Operating temperature (to): oF
Water content at ti and pm:
Water content at to and pm:
Inhibitor concentration (Win):
Water to be removed from gas (wG):
Molecular weight of inhibitor (MW)inh:
Hammerschmidt constant for inhibitor (KH):
Depression of hydrate formation temperature (Dth): oF
Instructions:1) Update input data in blue;2) View result.
W h=(MW )inh Δth
(MW )inh Δth+K H×100
I 100=W G
(100W out
−100W in
)
lbm MeOH/MMscf
WT % NeOH in Water= f (P , t )
Inhibitor requirement: 38.62 lb/MMscfDaily injection rate: 386.18 lb/day
58.16 gal/dayHourly injection rate: 2.42 gal/hour
Check:
= 12.63I 100=WG
1+KH
(MW )inh Δth−100W in