microflush controller flyer 10.2014
DESCRIPTION
manual del microflushTRANSCRIPT
10/2014
VAF Filtration Systems5270 Marshall Street, Arvada, CO 80002 USA
Phone +1 303 425 4242 Fax +1 303 425 0112www.vafusa.com
General Information
VAF’s MicroFlushTM filtration systemcontroller demonstrates VAF’s commitmentto providing quality and simplicity with themost advanced self-cleaning screentechnologies available today. VAF’sMicroFlushTM filter controller allows thecontrol and monitoring of a self-cleaningsystem with unprecedented features andflexibility at an economical price. VAF’sMicroFlushTM filter controller used inconjunction with VAF’s V-Series filtrationproducts is designed to meet GreenBuilding Inititative (LEED Qualified)requirements by minimizing water andenergy waste with this new and innovativetechnology.
MicroFlushTM Specifications
Housing • NEMA 3S
• 15 cm x 15 cm x 9 cm (6” x 6” x 3.5”)
Electrical input • 120/220 VAC 50/60Hz
• Battery - 12 VDC orStandard AA Batteries
• Solar Power
Electrical output • Continuous 24 VAC
• Latching 12 VDC
VAF FilterController
MicroFlushTM
FILTRATION SYSTEMS
• Steady 12 VDC
10/2014
VAF Filtration Systems5270 Marshall Street, Arvada, CO 80002 USA
Phone +1 303 425 4242 Fax +1 303 425 0112www.vafusa.com
Features
MicroFlushTM Controller
How To OrderTypical Installation
MicroFlushTM control panel
Tandem V500-4 inchfilter skid
120 VAC, 220 VAC or12 VDC powersource
NOT TO SCALE
up to 4 automaticfilter flush valves
MF__- __
Number of stations
Electrical input
Electrical input• Battery• Solar• 120/220 VAC
OPTIONS: Straps Stainless steel straps enable mounting controller directly to V-Series Filter body (V-250 to V-2000).
Model• MF1-DC• MF1-DCS• MF1-AC• MF4-AC
Menu Driven Programming• Easy-to-use Scroll Key Programming
- Two line backlit LCD display
- Password protected access
• Adjustable Features
- Adjustable Units (PSI, kPa, bar)
- Adjustable DP threshold
- Adjustable flush duration
- Schedule hours of opreration
• Flush Initiation Options
- Manually
- Adjustable time interval
- Adjustable pressure differential (DP)
System Faults Detected • Excessive Flush Faults (an industry first)
- Monitors excessive flush waste
- “Continuous flushing” alarm
- Max flush per hour
- Max consecutive flush attempts
System Performance Recorded
• Displays Last Flush Interval
• Historical Operational Data Recorded
• Ideal for Monitoring Filtration System Performance
• 120/220 VAC