monitoring physical activity in medical applications....2016/04/27  · trl 7 - design for...

16
Monitoring physical activity in medical applications.

Upload: others

Post on 27-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

Monitoring physical activity in medical applications.

Page 3: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

Wearable Healthcare Digital health support tools

for patient and doctor

Lifestyle Advice

Questionnaires

Self Management

Self Monitoring

Wearable Monitoring

Page 4: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

“Healthy” Activity • Sufficient activity level

• Frequent activity

• Good quality of movement

• Safe movement

“Unhealthy” Activity • Falling

– Long-lie after fall

• Increased fall risk:

– stumbling

– Bad balance and coordination

– Fall history

• Less daily activity

• No variation in activity

Negative influence

Positive influence

Page 5: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

Anemnesis (analysis)

Treatment

(advice)

Investigation (measurement)

Monitoring in healthcare

Page 6: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

From concept to medically certified product

Medical development process

Certified, validated, production-ready design

Product validation and certification

Design for production

Prototype demonstration in pilot study

Prototype validation in lab environment

Prototype development

Experimental validation

Technological proof-of-concept

Conceptual ideas

MUMC+ Engineers

Page 7: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 1 – Conceptual ideas

Intended use

Page 8: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 2 – Technological proof-of-concept

Wearables dev kit

Page 9: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 3 – Experimental validation

Pre-clinical testing

Page 10: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 4 – Prototype development

Prototype development

Page 11: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 5 – Prototype validation in lab environment

Lab testing & validation References:

- Concurrent Validity of the MOX Activity Monitor Compared to the ActiGraph

GT3X. Van der Weegen et al. (2015)

- Usability testing of a monitoring and feedback tool to stimulate physical activity.

Van der Weegen et al. (2014)

Accuracy Usability

Page 12: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 6 - Prototype demonstration in pilot study

Pilot study

Page 13: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 7 - Design for production

Production development

3D ACC

BT 4.0

BT 2.0

SD card

Mass storage device

Power management / battery charging

User Interface

Firmware features: Real-time streaming / Embedded algorithms / Data logging

EMG 2 / 4 / 8 ch.

3D magneto

Temperature

Pressure / Moisture

3D gyroscope

Example final form factor

DFx -> Design for size, reliability, manufacturing, assembly, safety, testing, cost …

Page 14: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 8 – Validation & certification

Medical activity monitoring

Effects

Effective treatment

Health improved for

COPD

Efficient compared to

additional therapy

Patient satisfaction

Page 15: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

TRL 9 - Certified, validated, production-ready design

Medical activity monitoring

Consumer product Healthcare product

Cost of goods Safe

Speed to market Predictable - accurate

Features / values Traceable

Marketing Effective

Design Usable

Logistics Secure & private

… ...

Page 16: Monitoring physical activity in medical applications....2016/04/27  · TRL 7 - Design for production Production development 3D ACC BT 4.0 BT 2.0 SD card Mass storage device Power

Freek Boesten Product manager Wearable Healthcare

Tel: +31 43 388 1371 Mob: +31 6 5432 8206 [email protected]

www.maastrichtinstruments.com