monitoring systems for water flow, level and weather | telemetry...
TRANSCRIPT
for Dirty or Aerated Liquids
Non-ContactingDoppler Flow Meter
Greyline PDFM 5.1
Displays, Datalogs
Transmits and Totalizes
Flow in Closed Pipes
Simple -key Calibration5
300,000 point Data Logger
4-20mA Output
10-Digit Totalizer
AC/DC Operation
Built-in Rechargeable Battery
Versatile, Easy to Use
Ideal for Problem Liquids
Use a Greyline PDFM 5.1 Portable Doppler Flow Meter to monitor andbalance flow, or to troubleshoot flow problems in pipes. It is ideal tofullevaluate performance of in-line flow meters and can be installed,calibrated and started-up in minutes. Use it for projects where apermanent flowmeter is not required or to temporarily replace installedflow transmitters.
The PDFM 5.1 ultrasonic sensor is on the outside of a pipe. Anclampedacoustic pulse is reflected back to the sensor from particles or gases inthe flowing liquid. The flow rate of any fluid can be measured as long as itcontains air bubbles or solids. It is ideal for wastewater, slurries, sludge,and most chemicals, acids, caustics, and lubrication fluids.
With its internal battery the PDFM 5.1 can be operated all day and thenrecharged overnight. For continuous use it can be powered by a supplied110-240VAC wall plug adapter. A 300,000 point data logger is built-in.
Fast, Easy Flow MeasurementUltrasonicwith Non-Contacting Sensor
Portable Flow Meter
Troubleshoot Flow from Outside a Pipe
Quick, Easy Flow Measurements from Outside a Pipe
Each Greyline PDFM 5.1 comes complete with rugged watertight carrying case,strap-on sensor and stainless steel mounting kit. Use the simple 5-key menusystem to select units of measurement and to calibrate to any pipe diameter ½”(12.5 mm) or larger.
Simple start-up and Calibration
Sensor mounting and a full calibration can be done in just a few minutes. It isfast and easy! Put coupling compound ( ) on the sensor facegel included andmount on the outside of a pipe with the stainless steel mountingthe sensorbracket (supplied). fiveUse the -key calibration system to enter pipe diameterand to select your choice of engineering units (gallons, litres etc.) The PDFM5.1 will immediately begin to display, transmit and totalize.
No Calculations - No Programming Codes
Select your choice of display units: the PDFM 5.1 will display and totalize flow volume in gallons, lite s, cubic feet or cubicrmeters. If you change from one measurement system to another, the PDFM 5.1 will automatically and instantly calculateand convert the flow display and totalizer. alibrate to pipe size using the keypad to enter inside diameter.C the
Built-in 0,000 point Data ogger30 l and PC Software
Set up the PDFM 5.1's data logger to store time and date-stamped flow values from 1 second to minute intervals. Or use0 5the convenient 'Flow Report' format where total, minimum,maximum and average flow rates are stored in your choice ofhourly or daily summaries. Transfer flow logs to your PC or laptopthrough the PDFM 5.1's outpu . Greyline Logger softwareUSB t(included) displays data in both graph and table formats andexports to graphic or text file formats for use in other programs.
“Sleep Mode” for Extended Data Logging onBattery Power
Sleep mode extends battery life for long-term data logging atlocations where AC power input is not available. Between logging intervals the flowmeter drops into a stand-by mode untila flow reading is requested by the data logger. Flow rates are sampled continuously for 10 seconds and then the PDFM5.1 returns to sleep until the next logger point is required. With 5 minute sample intervals the PDFM can data log for about18 days on battery power.
New Signal Processing for reliable Accuracy
The PDFM 5.1 Doppler flow algorithm filters out background noise andinterference. The high speed digital signal processor discriminates againstweak and distorted signals. When the processor cannot measure accuratelythe meter will display zero flow and indicate low signal confidence.
Battery Powered a Full Day’s Workfor
With its built-in rechargeable battery, you can operate the PDFM 5.1 .NiMH up to 18 hours continuously Displaybrightness is adjustable to conserve power. (100-240VAC to activate the 4-20mA outputPlug into an AC outlet 50/60Hz)and recharge fully in to hours. You can continue to use the PDFM 5.1 while charging.to 6 8
Solve Flow Problems� Troubleshoot and Balance Flow� Check Performance of Pumps or other
Flow Meters
DOPPLER SIGNALBACKGROUND
NOISE
General Specifications
Flow Rate Range:
Pipe Size:
Display:
Power Input:
Outputs:
Data Logger:
PC Software:
Electronics Operating Temperature:
Electronics Enclosure:
Carry Case:
Accuracy:
Calibration:
Language Selection:
Sensitivity:
Approvals:
Sensor Specifications
Standard Model PSE :4
Sensor Mounting Kit:
Operating Temperature:
Options
Sensor Cable:
Sensor Mounting:
PDFM 5.1 Specifications
Greyline PDFM 5.1 Portable Doppler Flow Meter
± 1 ± 3 in most applications0. to 40 ft/sec ( 0.0 to 12.2 m/sec)
Ultrasonic Sensor mounts on any pipe from ½" to 180" ID (12.5 mm to 4.5 m)
White, backlit matrix - displays flow rate, totalizer, operating mode and calibration menu
Built-in NiMH battery for up to 18 hours continuous operation
External with 24 inputcharger 100- 0VAC 50/60Hz
4-20mA (500 ohm) when AC powered
USB for Data Log transfer by direct PC connection
P 30rogrammable 0,000 data point capacity, time and date stamped or formatted flow
reports including total, average, minimum, maximum and times of occurrence
‘ ’ s Vista or higher. RGreyline Logger for Window etrieves, displays and saves data log files
-10° to 140°F (-23° to 60°C)
Portable, ABS enclosure
Rated IP67 with protective molded foam insert
±2% of reading or 0.1 ft/sec (0.03 m/sec). Requires solids or bubbles minimum size of 100
microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%
Built-in -key programming with user-friendly calibration menu. Password protected.5
English, French, Spanish
Adjustable , Damping: adjustablecut-off
Charger is CE and UL approved. The PDFM 5.1 is not certified for use in hazardous rated
locations
Clamp-on, single-head ultrasonic for pipes from ½" to 180" ID (12.5 mm to 4.5 m) with12 ft (3.4 m) shielded dual-coaxial cable
Stainless steel pipe clamp and 5.3 oz. (150 g) silicone coupling compound
-40° to °F (-40° to °C)300 150
50 ft (15 m) sensor cable extension, shielded, with connectors
Extra silicone coupling compound. Additional stainless steel pipe clamps
Dimensions
ENCLOSURE
PSE4 ULTRASONICDOPPLER SENSOR
4.33”
110 mm
8”
204 mm
1.6”
41 mm
12 ft / 3.6 m
SIDE VIEW
3.375” / 85 mm1.375”
35 mm
1.5”
38 mm
END
VIEW
Ideal for Tough Flow ApplicationsThe PDFM 5.1 works best with difficult liquids in“ ”applications that would damage regular flow meters.Because the sensor is mounted on the outside of thepipe, there is no contact with the moving fluid.
The sensor straps onto the outside of pipe "ultrasonic s ½(12.5 mm) ID or larger and measures flow in common pipematerials: PVC, carbon steel, stainless steel, cast iron,fiberglass, and lined pipes...any pipe that conductsultrasound. Doppler signals cannot be transmitted throughpipe walls which contain air pockets (materials like concrete andwood), or loose insertion liners (with an air gap between the liner and pipewall). Because the sensor is so easy to install you can test any application andpipe material in a few minutes.
How it WorksThe PDFM 5.1 ultrasonic sensor injects highfrequency sound through the pipe wall and intothe flowing liquid. Gas bubbles or solidssuspended in the liquid reflect the ultrasonicsignal back to the sensor. When this soundis reflected from moving bubbles or particlesit is returned to the sensor at an alteredfrequency. This frequency shift is called theDoppler effect. The PDFM 5.1 continuouslymeasures the change from it's transmittedfrequency to the received frequency toaccurately calculate flow.
PDFM 5.1 PortableDoppler Flow Meter
� No Obstruction No Pressure Drop–� Just Minutes to Install and Calibrate
Contact a Greyline sales representative in your area or phone one of our salesengineers. Describe your requirements and receive our prompt quotation.
Take advantage of Greyline's applications experience. Phone 1-888-473-9546 foradvice and information on applications, installation or service for Greyline instruments.
The Greyline PDFM 5.1 Portable Doppler Flow Meter must meet your requirements.Discuss your application with a Greyline representative to arrange a performance test.
Quality of Materials and Workmanship - Each instrument manufactured by Greyline iswarranted against defects in materials and workmanship for a period of one year fromdate of purchase. Refer to our limited warranty included with each product.
How to Order
Applications Support
No Risk Appraisal
The Greyline Guarantee
Recommended or:f
� sewage
� treated wastewater
� aerated water
� sludge and slurries
� chemicals and solvents
� viscous liquids
� abrasives
� food products
� pulp stock
� acids and caustics
The PDFM 5.1 is ideal to
measure full pipe flow of
any liquid containing gas
bubbles or solids larger
than 100 microns and in
concentrations greater
than 75 ppm.
SOUND WAVETRANSMITTEDFROM SENSOR
BUBBLES OR SOLIDSREFLECT SOUND
SOUND WAVESREFLECTEDBACK TO SENSOR
SENSOR
USA: 11451 Belcher Road South, Largo, FL 33773Tel: 315-788-9500 / 888-473-9546 Fax: 315-764-0419
Canada: 16456 Sixsmith Dr., Long Sault, Ont. K0C 1P0Tel: 613-938-8956 / 888-473-9546 Fax: 613-938-4857
Internet: www.greyline.com E-mail: [email protected]