Special features 100% quality control of the checking process Powerful algorithms for acquiring and assessing switching points and locking operations Universal twin-channel amplifier for many of the usual market sensors with TEDS sensor detection Memory function for results, curves and device settings Convenient integration into the automation system by means of standardized fieldbus interfaces MP85AS MP85ADPS EASYswitch μP A D Intelligent signal conditioning and powerful algorithms for acquiring and assessing switching points and locking operations Keyboard and display Carrier-frequency excitation voltage 4.8 kHz Switching test inputs, control inputs and control outputs 24 V Voltage supply, electrically isolated Profibus DP interface (for MP85ADPS) A D MMC memory card Power supply for active transducers 5 V or 24 V SSI trans- ducer "10 V CANopen interface MP85AS / MP85ADPS FAST Ethernet interface EEPROM B2359-2.0 en Data Sheet

Upload: trinhnga

Post on 08-Apr-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Special features

− 100% quality control of thechecking process

− Powerful algorithms foracquiring and assessingswitching points and lockingoperations

− Universal twin-channel amplifierfor many of the usual marketsensors with TEDS sensordetection

− Memory function for results,curves and device settings

− Convenient integration into theautomation system by means ofstandardized fieldbus interfaces

MP85A−SMP85ADP−SEASYswitch

μPA

D

Intelligent signal conditioning andpowerful algorithms for acquiringand assessing switching points

and locking operations

Keyboard and display

Carrier-frequency excitationvoltage 4.8 kHz

Switching testinputs, controlinputs andcontrol outputs

24 VVoltage supply,electrically isolated

Profibus DPinterface(for MP85ADP−S)

AD

MMC memorycard

Power supply for active transducers5 V or 24 V

SSItrans-ducer

�10 V

CANopeninterface

MP85A−S / MP85ADP−S

FAST Ethernetinterface

EEPROM

B2359-2.0 en

Dat

a S

heet

Page 2: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

DescriptionSwitch checking device for production and laboratoryWith EASYswitch, the switching characteristics of the switching elements and locking systems are recorded bymeans of force/displacement or torque/angle of rotation sensors. Tactile feedback when operating push buttonsand rotary actuators, as well as the switching characteristics of single pole or multipole voltage switches can beobjectified and documented with EASYswitch.With the MP85A−S EASYswitch, quality assurance can be integrated into the checking process. Operationalreliability, economic efficiency and product liability are of paramount importance.EASYswitch includes all the functions necessary for 100% checking, together with user-friendly, flexible softwarethat allows the user to configure variable test sequences without in-depth programming knowledge.

Performance features and advantages:• Easy configuration and starting up with free parameterization and visualization software (PME Assistant)

Download from www.hbm.com − Support − Software• Precise process analysis to meet requirements in compliance with standards• Flexible system for monitoring different workpieces, 1000 different device settings and 1000 different

workpieces/processes• Storage of results, curves and statistics, as well as the device settings in the device itself, on a memory card

or on an external PC• Continuous traceability thanks to integrated process control and the statistics functions of the stored processes• Integration via digital inputs/outputs or integrated fieldbus interfaces to primary control systems, such as a PLC

control or process control systems• Flexible application, tailored to use at manual workstations• Expansion of existing machines, easy to install

A) Haptic test of a locking system by means of force/displacement monitoring

Evaluation criteria:

1. Force at mechanical switching peak Fa

2. Drop in force after mechanical switching peak Fa−Fr

3. Click ratio (Fa−Fr) / Fa x 100%

4. Displacement differential Sr−Sa

5. Force/displacement ratio (Fa−Fr) / (Sr−Sa)

F /

N

S / mmSa Sr

Fq

Fr

Fa

Fr

1.

2.

4.

5.

B2359-2.0 enHBM 2

Page 3: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

B) Switch test of electrical switching systems

Solutions for test functionsAs many as 5 switching events can be electrically verified simultaneously or consecutively, via the integrated digitalinputs:

− Is the switching point or the switching process in the switching test window ?− Is the direction of actuation (break/make) correct ?− Is the actuating force / actuating moment correct?− Have there been switching repetitions?

Measurement curves and results are recorded and evaluated online. If one or both conditions are not met, an NOKwindow is activated.

OK / NOK testing controls production and helps to minimize downtime. Warning limits monitor the productionprocess and make it possible to protect the machines. Control signals control start/stop and limit value cutoff eithervia digital inputs, the Ethernet interface or the Profibus-DPV1 interface (optional).All the individual and cumulative results, switching curve curves and switching events (break/make function) arestored.

MP85A(DP)−S function blocks

Setting Measuring

TEDStransducerand amplifier

Evaluationcriteria

Loading/Storing

Data storage Specialfunctions

Measuring/Visualization

Immediate utilization of evaluation criteria• Sensor data does not need to be set manually when using sensors with TEDS technology• The TEDS data is read via the sense leads from the sensor (instead of an additional cable). The cable and the

connector can be deployed as usual.• The MP85A−S is ready for use in a matter of seconds

B2359-2.0 en HBM3

Page 4: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Process analysis with tolerance windows / measurement and visualization

The following windows are used to evaluate the production process:

1 alarm window Limits at which an alarm is triggered. This window is used to protectthe machine.

1 range window Defines the range in which measured values are stored, within which all the other tolerance windows are positioned.

1...9 tolerance windows for analyzing the switching and locking actions. In switch check mode, the switching contacts are evaluated via the digital inputs. Haptic windows monitor the switching characteristic.With standard tolerance windows, there is a free choice of incoming and outgoing sides;the windows can be evaluated in real time. Mean value windows are also possible. All window types can be used as required and can overlap.

Thread-in window:Start window operates in real time (to protect the machines and the system)

Process window:Monitors the force/displacement (or torque/angle of rotation) curve of the switch or locking system

Thresholds:Thresholds monitor the process curve in defined ranges.

Switch check window:Monitors the function and position of the electrical contact of a switch. As many as 5 switchingcontacts can be checked in one procedure.

Block window:The end window monitors the block force.

Haptic window:Monitors the switching characteristic of the switch or the locking system.

B2359-2.0 enHBM 4

Page 5: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Systems of coordinates:Tolerance window coordinates can be defined absolutely or relatively (dynamically). Use the relative system ofcoordinates if the absolute position of the workpieces/test specimens is not always the same. It is possible to mixthese two windows.

Application:

Analysis with tolerance windowsWith relative x coordinates, all that is measured is the relative movement as from the start or end position, relativeto the x axis of the two test pieces.

Start and stop conditionsThe start and stop conditions are used to synchronize measurement control to the checking process. The signalingoptions are via: CANopen, PROFIBUS-DPV1, digital input or internal trigger.Start and stop conditions are available for a wide variety of applications, such as:

• external start and stop signal• target value y and overshoot time• target value x and overshoot time• target value x and target value y• standstill recognition• Stop on reverse motion for channel x

Standard operator panels (IPCs) can be used to visualize the process in situ. The device can also be integratedinto existing systems later on. Connection is made via the CAN Profibus-DPV1 or FASTEthernet interface of theMP85A-S devices.

B2359-2.0 en HBM5

Page 6: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Quality control / statistics

Quality and tool wear for the checking process areassessed using statistics functions.

Statistics graphics can be called to clearly displaythe OK and NOK processes.

Global statistics with a process counter aregrouped by parameter sets.

The tolerance window result can be read at aglance for each parameter set.

This allows

− tool wear

− component tolerances or

− damage to a machine

to be detected early.

The graphic windows in Counting can be used toanalyze the distribution of the OK and NOKprocesses individually for each window.

Counting automatically calculates the distributionof the minima and maxima with accompanyingstandard deviation.

Statistics data are stored in the device.

Data management / loading and storing

With the MP85DP−S, it is possible to store andclearly visualize results, curves, statistics and thedevice settings. This allows processes to beanalyzed later on and ensures 100% traceability.

You can choose whether to store the data on yourPC or on the multimedia card in the device.

Storage on an MMC card can be set up as a circularbuffer for the last 1000 curves.

In both cases, curves and/or results can be storedin ASCII or Qdas format:

− NOK processes only or

− OK processes only or

− all processes

The data on the MMC card can then be transcribedto the PC.

A protocol providing all information in detail can beprinted out for every process, if needed.

B2359-2.0 enHBM 6

Page 7: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Management of production data

Ethernet

MP85ADP−Sproductionmonitoring

The curve and result data can be storedwith a component part number. This al-lows easy and unambiguous archiving.

Directory/componentpart number

Internal MMC

Directory/componentpart number

Utilizing the existing infrastructure

Using the standard Ethernet interface enables networ-ked systems with remote maintenance to be built up.

SpecificationsBasic device MP85A / MP85A DPAccuracy class 0.1

Supply voltage VDC 24; electrical isolation from the measurement system (typically500 VDC)

Permissible supply voltage range V 18...30

Power consumptionMP85A, typicallyMP85ADP, typicallyMP85A / MP85ADP, max.

WWW

7910

Behavior in the event of a supply voltage failure Automatic data retention after power failure

Typical backup battery life (CR2032) for the realtime clock years 5

Evaluation unit specificationsMax. number of measured value triplets

(channel x), (channel y), (time)4000 (automatic data reduction)

Sampling rate Hz 2400

Start conditions Internal start signalExternal start signal

Target value xTarget value y

Target value x + target value y

Stop conditions Internal stop signalExternal stop signal

Target value y + overshoot timeTarget value x + overshoot time

Target value x + target value y + overshoot timeStandstill recognition

Return channel x

Process-end conditions External signalSimultaneous with end of start condition

Target value xTarget value y

Target value x and target value y

Number of parameter sets / measurement programs in the device 31 plus factory setting

Number of parameter sets on the optional MMC 31 in XML format

1000 in binary formatTypical switching between parameter sets ms 200

B2359-2.0 en HBM7

Page 8: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Evaluation

Tolerance band 64 interpolation points, adjusted as required

Envelope curve 4 tolerance ranges, 64 interpolation points, adjusted as required

Tolerance windows, maximum number 9

Type of window oblique or straight

Evaluation methods per window Switch check

Haptic test

Real time evaluation (online for machine protection)

Analyzing the course of the curve in the window (min/max)

Analyzing the mean x or y value in the window

Analyzing vertical or horizontal thresholds (online)

x coordinates for the tolerance window absolute or relative to the start position, orrelative to the end position

y coordinates for the tolerance window absolute or relative to Fmin of tolerance window 2,relative to Fmax of tolerance window 2 orrelative to Fmean of tolerance window 2

Typical duration of offline evaluation, end window ms 6

Typical duration of offline evaluation, straight window ms 5 + 0.1/measurement pair in window

Typical duration of offline evaluation, oblique window ms 10 + 0.3/measurement pair in window

Statistics (separately for each parameter set)

Maximum number of test cycles 4 x 109

Number of histogram classes for 2 values(xmax, xmin, ymax, ymin)

9 per tolerance window

Transducer and amplifierCarrier frequency kHz 4.8 �1 %

Bridge excitation voltage Veff 2.5 �5 %

Transducers that can be connectedStrain gages, half and full bridgesInductive half and full bridges, LVDTsPotentiometric transducers

ΩmHΩ

170 ... 20004 ... 160

170 ... 2000

Input sensitivities Measuring range (mV/V)

4 100 1000

mV/V 0.2 ... 4 3.5 ... 100 50 ... 1000

Length of transducer cable, max. m 500

Scaling range, max. digits 999999, at 10% of the input measuring range

Scaling range, min. digits 100, at 100% of the input measuring range

Permissible common-mode voltage, max. V �5.5

Common-mode rejection0...60 Hz0...1000 Hz0...4800 Hz

dBdBdB

�120�96�50

Linearity error % � 0.03

Noise voltage, typically Measuring range (mV/V)

4 100 1000

0...1 Hz0...10 Hz0...100 Hz0...1000 Hz

μV/VppμV/VppμV/VppμV/Vpp

0.10.25

12

2.562550

2560250500

Sampling rate, max. 1/s 2400

B2359-2.0 enHBM 8

Page 9: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Measurement frequency range, adjustable

4th order low-pass with Bessel characteristic

Nominal(rated)

value fc(Hz)

−1dB(Hz)

−3dB(Hz)

Phasedelay(ms)

Rise time(ms)

Overshoot(%)

1000 980 1400 0.550 0.260 4

500 440 690 0.860 0.510 1.5200 190 320 1.6 1.11 1.5100 100 160 2.9 2.13 1.350 51 83 4.6 4.24 1

20 25 41 8.2 8.36 110 13 21 15.5 16.8 05 6.1 10.3 30.2 33.4 0

2 3.1 5.2 60 67 01 1.6 2.6 119 137 0

0.5 0.79 1.30 240 272 0

0.2 0.19 0.32 950 1070 00.1 0.09 0.16 2500 2170 00.05 0.049 0.081 3750 4280 0

Shunt calibration mV/V 1�3%

Effect of operating voltageon zero pointon sensitivity

% f.s.% f.s.

� 0.01� 0.01

Effect of 10 K variation in ambient temperature Measuring range (mV/V)4 100 1000

on zero point full bridgeon zero point half bridgeon sensitivity

μV/VμV/V

%

110

0.05

2040

0.05

2002000.05

Long-term drift over 48 h(measuring range 4 mV/V; 0.5 h after activation)

μV/V 2

DC-voltage transducersTransducers that can be connected DC-voltage transducers, voltage sourcesNominal (rated) measuring range V �10Input signal range V �10.5Scaling range, max. digits 999999, at 10% of the input measuring rangeScaling range, min. digits 100, at 100% of the input measuring rangeInternal resistance of the signal source kΩ �1Permissible common-mode voltage, max. V 2Measurement frequency range, adjustable (−1 dB) Hz 0.05 ... 1000Filter characteristics Bessel, 4th orderLinearity error % �0.03Sampling rate, max. 1/s 2400

Incremental transducersTransducers that can be connected Incremental transducers (up/down counter with zero index

signal)

Voltage supply 5 V, max. 150 mA or 24 V, max. 300 mA

2-channel mode Time-division multiplex methodInputs (F1 (�), F2 (�), Ix (�)) Differential inputs (RS422)

Input levelsLow levelHigh levelEach line to measurement ground, max.

VVV

� 0.8�2�14

Hysteresis V 0.07

Permissible common-mode voltage, max. V −7 / +12

Input impedance, typically kΩ 12Detection of direction of rotation via �90o phase-shifted signal F2Pulse counting input range pulses 0 ... 999999Maximum pulse rate pulses/

s1 000 000

Interval between 2 successive edges F1(�), F2(�)

ns �400

Scaling range, max. digits 20 at 1 pulseScaling range, min. digits 1 at 10000 pulsesMeasurement frequency range, adjustable (−1 dB) Hz 0.05 ... 1000

Sampling rate, max. 1/s 2400

B2359-2.0 en HBM9

Page 10: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

SSI transducersTransducers that can be connected Displacement and angle transducers with SSI interfaceVoltage supply 5 V, max. 150 mA or 24 V, max. 300 mA2-channel mode Time-division multiplex methodData input D(�) Differential input (RS422)Input levels, data input D (�)

Low levelHigh levelEach line to measurement ground, max.

VVV

�0.8�2�14

Hysteresis V 0.07

Permissible common-mode voltage, max. V −7 ... +12

Clock output Cl (�)Differential output voltage Cl(�), without load, max.Differential output voltage Cl(�), RL = 50 ohms, min.

VV

Differential output (RS422)5.82

Common-mode voltage at Cl (�), max. V 3

Short-circuit current, clock output Cl (�), typically mA 100

Resolution, single turn bits 12, 13Resolution, multi-turn bits 24, 25Scaling range, max. digits 20 at 1 pulseScaling range, min. digits 1 at 10000 pulsesMeasurement frequency range, adjustable (−1 dB) Hz 0.05 ... 1000Sampling rate, max. 1/s 1200Baud rates kBaud 100, 200, 500, 1000

Coding Gray code

Potentiometric displacement transducer see transducer carrier frequency

General specificationsLimit value switches

Number 4 per channel

Reference level gross

Hysteresis % 1 ... 100

Adjustment accuracy digit 1

Response time, typically (fc=1000 Hz) ms �2

Control outputsNumber 4 (MP85ADP(−S)) / 8 (MP85A(−S)), electrically isolated

Function Process OK/NOK, process started/running, processfinished/valid, limit values 1−4, transducer test result, result

tolerance window, status MMC, status channel x/y

Nominal (rated) voltage, external power supply VDC 24

Permissible supply voltage range V 10 ... 30

Maximum output current per output A 0.5

Short-circuit current, typically (Uext. = 24 V, RL� 0.1 ohm) A 0.8

Short-circuit period unlimited

Isolation voltage, typ. VDC 500

Control inputsNumber 1 (MP85ADP) / 5 (MP85A), electrically isolated

Function Switch test (up to 5 with MP85A−S), zero balance, shuntcalibration, parameter set selection, start/stop process,

transducer test, store/clear statistics

Input voltage range LOW V 0 ... 5

Input voltage range HIGH V 10 ... 30

Input current, typically, (High level = 24 V) mA 12

Isolation voltage, typ. VDC 500

Ethernet interfaceTransmission protocol MBits/s TCP/IP, can be networked per IEEE802

Transfer rate, max. MBits/s 10 and 100 (automatic selection)

Topology (twisted pairs) 2LED display for reviversLED display for revivers

Transmitter (RxD/TxD) and link 2Line length, maximum m 100

Cable type UPT category 5 or shielded twisted pair (STP)

Connecting socket RJ−45

B2359-2.0 enHBM 10

Page 11: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

CAN interfaceProtocol CAN 2.0B; CANopen compatible

Hardware bus link to ISO 11898

Baud ratesMaximum line lengths

kBits/s

m

1000 500 250 125 100 50 20 10

25 250 500 1000 600 1000 1000 1000

Termination resistor connectable by switch

Connection terminals

Multi Media Card (memory card on Flash basis)

Function Storage of: parameter sets, curves and results, statistics,circular buffer of last 1000 curves, file transfer to PC

Usable types MBytes 8, 16, 32, 64, 128, 256, 512, 1024

Data transmission rate, typically kBytes/s

2−8

File system DOS, FAT format

Display

Type 2-line, 8-character alphanumeric, LCD

Keyboard Touch-sensitive keypad with three keys, pressure-sensitive

Temperature rangeNominal (rated) temperature range oC 0 ...50Operating temperature range oC −20 ... +50Storage temperature range oC −20 ... +70

Degree of protection IP20

Dimensions (W x H x D) mm 55 x 146 x 156

Weight, approx. g 800

Profibus DP interface (MP85ADP only)

Protocol Profibus DP Slave, per DIN19245−3

Baud rate, max. MBaud 12

Slave address 3−123, set via the keyboard

Profibus ID number Hex 699

Configuration data bytes 5

Parameter data , max. bytes 6 (+7DP standard)

Function Access to and parameterization of all MP85A functions (remotecontrol)

Parameterization (asynchronous) per DPV1 standard

Input data , max. bytes 142

Output data, max. bytes 40

Update rate, inputs ms 1 (for 4 measured values)

Update rate, outputs ms �10, for zero setting, limit values

Diagnostic data bytes 48

Profibus connection 9-pin sub-D (DIN19245−3), electrically isolated from powersupply and measurement ground

B2359-2.0 en HBM11

Page 12: MP85A S MP85ADP S Data Sheet - hottinger.skhottinger.sk/Prospekty/Elektronika/spol/PME/MP85/p_MP85a_s_e.pdf · −100% quality control of the ... Force at mechanical switching peak

Dimensions of the PME modules:

59 152

61

150

Scope of supply

4 plug-in screw terminals, coded Phoenix order number:1x voltage supply and CAN, 6-pin MV STBW 2.5/6−ST−5.08 GY

2 x transducers, 8-pin MCVW 1.5/8−ST−3.81 GY

1x In/Out digital, 8-pin MC 1.5/8−ST−3.5 GY

FASTpress Suite system CD with:

free PME Assistant setup software

Online Help with Tricks&Tips

Quick Reference Guide for beginners

PME Assistant PLUS (demo version) with EASYsetup: User administration and EASYteach: statistical process analysis and report generation

MP85A Toolkit:

Function module kit for creating separate interfaces on operator panels via Ethernet under Windows XP, Windows CE and WindowsMobile

MULTImonitor (demo version of the production software for simultaneous display of up to 4 checking processes)EASYmonitor CE (demo version of the production software for operation at a terminal with Windows CE operatingsystem)EASYmonitor Mobil (application for operation with a PDA or pocket PC)

Accessories (not included in the scope of supply):DT85: 1/4 VGA b/w display for visualization and parameterization of several MP85As via the CAN interface

Multimedia card (MMC); e.g. Sandisk (www.sandisk.com)

Standard flat ribbon cable, 10-pin, 1.27 mm pitch

Hottinger Baldwin Messtechnik GmbH

Im Tiefen See 45, D-64293 Darmstadt, GermanyTel.: +49 6151 803-0 Fax: +49 6151 803 9100Email: [email protected] Internet: www.hbm.com

Modifications reserved. All details describe our products in general form only. Theyare not to be understood as express warranty and do notconstitute any liability whatsoever.

B2359-2.0 en