municipality of sogod - southern leyte state … sought in all the provisions of the national...
TRANSCRIPT
A
PROJECT TITLE: SHEET CONTENT: SHEET #:
1
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
5
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
PERSPECTIVE 1
S E A L :
ADDRESS: SOGOD, SOUTHERN LEYTE
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:PREPARED BY:
ENGINEER - 1
GERALD B. HANDAYAN
PERSPECTIVE 2
LOCATION MAP
USSC
OVAL
I.E. BLDG.
MGT. BLDG.
2-STOREY
ACADEMIC BLDG.
THIS SITE
LOCATION MAP
NOT TO SCALE
UNIVERSITY LIBRARY
A
PROJECT TITLE: SHEET CONTENT: SHEET #:
2
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
5
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
GROUND FLOOR PLAN
S E A L :
ADDRESS: SOGOD, SOUTHERN LEYTE
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
6.025
21.213
3.450
6.325
7.7256.2506.250
6.025 6.250 6.250 6.025
7.2756.025
GROUND FLOOR PLAN
SCALE 1:200M
STAIRS
RAMP
UTILITY ROOM
LOBBY AREA
RECEIPTION
TO
SECOND
FLOOR
hall way 3 m wide
opac area
FEMALE CR
AREA
DISCUSSION AREA
shelves
shelves
108 SQ.M.
table
self-service
RESERVED SECTION
check out
table
photocopy area
CVM
MALE CR
E - LIB ROOM
6.025
7.725
7.275
6.100
3.450
magz & news
rack
SERIALS SECTION
table
table
table
table
table
shelves
shelves
shelvesshelves
shelves
shelves
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
shelvesshelvesshelvesshelvesshelvesshelves shelvesshelvesshelves
table
table
table
table
table
table
table
table
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelves
shelvesshelves shelvesshelves shelvesshelves shelvesshelves shelvesshelves shelvesshelves shelvesshelves
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
table
book drop
2.391
11.057
45°
MAIN LIBRARY
LOUNGING
AREA
waiting area
6.0256.025
45.575
SD
D1
D1
D3
D2
D2
W1 W1W1 W1 W1
W2
W2
W2
W4
W3
LwTw
Gf
Gf
Gf
Gf
Gf
Gf
Gf
Gf
Gf
Gf
TwTw
Ld
Ld
PREPARED BY:
ENGINEER - 1
GERALD B. HANDAYAN
GfGf
3.9802
30.5750
21.1000
3.4500
24.5500
9.5500
39.5500
UNIVERSITY LIBRARY
down
down
A
PROJECT TITLE: SHEET CONTENT: SHEET #:
3
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
5
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
RIGHT SIDE ELEVATION
LEFT SIDE ELEVATION
REAR ELEVATION
FRONT ELEVATIOM
S E A L :
ADDRESS: SOGOD, SOUTHERN LEYTE
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
REAR ELEVATION
FRONT ELEVATION
SCALE 1:200M
RIGHT SIDE ELEVATION
SCALE 1:200M
LEFT SIDE ELEVATION
SCALE 1:200M
SCALE 1:200M
3.400
0.600
0.800
1.500
2.400
0.500
1.100
3.400
0.600
0.800
1.500
1.100
1.500
0.800
PREPARED BY:
ENGINEER - 1
GERALD B. HANDAYAN
UNIVERSITY LIBRARY
A
PROJECT TITLE: SHEET CONTENT: SHEET #:
4
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
5
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
TYPICAL DOOR DETAIL
GLASS DOOR AND Gf DETAIL
SCHEDULE OF DOORS
TYPICAL WINDOW DETAIL
PREPARED BY: S E A L :
ADDRESS: SOGOD, SOUTHERN LEYTE
S E A L :
ENGINEER - 1
GERALD B. HANDAYAN
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
SCHEDULE OF DOORS
SD
D1
DESIGNATION WIDTH (m) HEIGHT (m) NO. OF UNITS
D3
Ld
D2
2.10 GLASS 2-1.20 1
2.101.00
KIND LOCATION
2
TYPE
DOUBLE SLIDING MAIN LIBRARY ENTRANCE
GLASS SWING E-LIB & DISCUSSION AREA
0.80 2.10 3 PANEL SWING M&F C.R., & UTILITY ROOM
DOUBLE SWINGGLASS 2-1.00 2.10 1 EXIT
4 LOUVER SWING M&F C.R.0.65 1.60
SCHEDULE OF GLASS & WINDOWS
W1
W2
DESIGNATION WIDTH (m) HEIGHT (m) NO. OF UNITS
W4
Lw
W3
1.501.00 5
1.00 3
1
1
10.60
NO. OF PANEL
5
6
2
3
4
SILL HEIGHT(m) TYPE
0.70
0.70
SLIDING
Tw
Gf
1.50 0.70 SLIDING
1.00 1.50 SLIDING
1.00 1.50 0.70 SLIDING
FIXED1.20 2.45
0.901
VARRY FIXED
2.5 VARRY VARRY1.40 0.10 FIXED
CLEAR WITH
CL
EA
R H
EIG
HT
USE 2X6 DOOR JAMB
FOR SWING FLUSH DOOR
WITH 1/4" MARINE PLYWOOD
DOUBLE WALLING ON 2X3 GOOD LUMBER FRAMING
FINISHED FLOOR LINE
TYP. DOOR DETAIL
SCALE NTS
0.65 m
1.6
0 m
FINISHED FLOOR LINE
LOUVERED DOOR
FINISHED FLOOR LINE
CL
EA
R W
IN
DO
W H
EIG
HT
SIL
L H
EIG
HT
CLEAR WITH CLEAR WITH CLEAR WITH
TYP. WINDOW DETAIL
SCALE NTS
0.90 20
SLIDING/FIXED GLASS WINDOW WITH 7/32" THK.
TEMPERED PLATE CLEAR GLASS ON ANODIZED
ALUMINUM FRAMING.(SUBMIT MANUFACTURER'S DRAWING DETAILS AND
CONSULT WITH PROJECT ENGINEER OR THE ARCHITECT.)
GLASS DOOR & Gf DETAIL
SCALE NTS
CLEAR WITHVERIFY VERIFY
CL
EA
R W
IN
DO
W H
EIG
HT
VE
RIF
Y
FINISHED FLOOR LINE
FIXED
7
32
" THK. TEMPERED PLATE CLEAR
GLAS ON ANODIZED ALUMINUM FRAMING
(SUBMIT MANUFACTURER'S DRAWING DETAILS AND
CONSULT WITH PROJECT ENGINEER OR THE ARCHITECT.)
DOUBLE SWING GLASS DOOR WITH GRAB BAR
(MATERIALS SAME AS ABOVE)
SCHEDULE OF GLASS & WINDOWS
UNIVERSITY LIBRARY
6.0256.2506.2506.025
A
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
5 5
A PROPOSED
S E A L : PROJECT TITLE: APPROVED BY: SHEET CONTENT: SHEET #:
TEMPORARY STAIRS & RAMP'S ROOF PROVISION
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
UNIVERSITY PRESIDENT
PROSE IVY G. YEPES
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
UNIVERSITY LIBRARY
3.4500
TEMPORARY ROOF PROVISION PLAN
TYPICAL TRUSS DETAIL
SCALE 1:200M
WALL FRAMING DETAIL
RAMP STAIRS2ND FLOOR LANDING
ROOF FRAMING PLAN
SCALE 1:200M
NTS
NTS
1.0000
1.7000 1.7000
1.0000
FRONT ELEVATIONRIGHT SIDE ELEVATION
CORRUGATED G. I. ROOF
1/4" THK MARINE PLYWOOD
SECOND FLOOR LINE
0.70 m X 1.70 m
SWING TYPE PANEL DOOR
2"X2" coco lumber framing
(marine plywood)
ADDRESS: SOGOD, SOUTHERN LEYTE
PREPARED BY:
ENGINEER - 1
GERALD B. HANDAYAN
26.6262
5.6024
10 - 2"x3" x 26.6262 m coco lumber
9 - 3"x6"x5.6024m
co
co
lu
mb
er
2"x2" coco lumber
spaced @ 0.40 m
bothways
3"x6" coco lumber (column)
3"x6" coco lumber (beam)
1.70 m
1/4" thick marine plywood
coated with flat white enamel paint
SECOND FLOOR LINE
3"X6" COCO LUMBER
2"X3" COCO LUMBER
3"X6" COCO LUMBER
E
S E A L : PROJECT TITLE: SHEET CONTENT: SHEET #:
2
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
4
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
GROUND FLOOR LIGHTING LAY-OUT
6.025
3.450
6.325
7.7256.2506.250
6.025 6.250 6.250 6.025
7.2756.025
GROUND FLOOR LIGHTING LAY-OUT
SCALE 1:200M
RAMP
6.025
7.725
7.275
6.100
3.450
2.391
45°
6.0256.025
45.575
HALL WAY -UNDER GROUND LIGHTING LAY-OUT
1 2 3 4 5
6
7
8
9
11
10
12
13
14
15
to underground
pass
to underground
pass
UNIVERSITY LIBRARY
APROVED AS PER PLAN:
ELECTRICAL ENGINEER
ADDRESS:
E
S E A L : PROJECT TITLE: SHEET CONTENT: SHEET #:
3
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
4
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
GROUND FLOOR POWER LAY-OUT
6.025
3.450
6.325
7.7256.2506.250
6.025 6.250 6.250 6.025
7.2756.025
GROUND FLOOR POWER LAY-OUT
SCALE 1:200M
6.025
7.725
7.275
6.100
3.450
2.391
45°
6.0256.025
45.575
HALL WAY -UNDER GROUND POWER LAY-OUT
16
17
18
19
20
21
22
2324
25
272628
29
30
31
32
33
to underground
pass
33
UNIVERSITY LIBRARY
APROVED AS PER PLAN:
ELECTRICAL ENGINEER
ADDRESS:
E
APROVED AS PER PLAN: S E A L : PROJECT TITLE: SHEET #:
4
ELECTRICAL ENGINEER
ADDRESS:
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
4
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
ELECTRICAL DIAGRAM
SCALE
NTS
SHEET CONTENT:
ELECTRICAL DIAGRAM
UNIVERSITY LIBRARY
3 - 125.00 mm2 THHN OR EQUIVALENT
50 KVA Banking
60.00 mm2 THHN OR THWN - (3 phase)22.00 mm2 THHN OR THWN - (3 phase)
Distribution Panel
P
S E A L : PROJECT TITLE: SHEET CONTENT: SHEET #:
1
ADDRESS: SOGOD, SOUTHERN LEYTE
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
3
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
SEPTIC TANK DETAILS
PLUMBING JOINTS
CATCH BASIN DETAIL
PLUMBING SPECIFICATIONS
@ 0.10 m.o.c bothways
digestive chamber
leaching chamber
1.6
0m
0.2
5m
section
6" thk CHB
outlet
0.1
5m
0.1
5m
2.7
m0
.1
5m
0.15m
0.30 m airspace
0.50 x 0.50 manhole
3.00m
plan
manholeco
co
co
co
0.50 x 0.50 manhole
0.15m1.15m
comanhole
inlet
note:
adopt 12 mm Ø bars
0.15m
PLUMBING SPECIFICATIONS1. ALL PIPES PASSING THROUGH OR UNDER DRIVEWAYS SHALL BE PROPERLYPROTECTED AGAINST BREAKAGE WITH REINFORCED CONCRETE.2. ALL HORIZONTAL PIPINGS SHALL RUN IN A PRACTICAL ALIGNMENT AND ATUNIFORM GRADE NOT LESS THAN ONE PERCENT (1%) AND SHALL BE ANCHOREDOR SUPPORTED AT AN INTERVAL NOT TO EXCEED 1.50 METERS.3. ALL WALLS WITH PLUMBING ROUGH-IN SHALL BE 150 mm THICK CHB.4. WORKMANSHIP SHALL BE OF CHARACTERISTICS AS TO FULLY SECURE THERESULT SOUGHT IN ALL THE PROVISIONS OF THE NATIONAL PLUMBING CODE OFTHE PHILIPPINES.5. INSTALL ALL PIPING IN ACCORDANCE WITH THE MANUFACTURER'SINSTRUCTIONS AND SPECIFICATIONS.6. UPON COMPLETION OF THE WATER SYSTEM, FLUSH OUT LINES TO CLEARSYSTEM OF PARTICLES, DIRT AND CLEAN ALL VALVES.7. ALL PLUMBING INSTALLATIONS SHALL BE DONE UNDER THE DIRECTSUPERVISION OF A DULY LICENSED MASTER PLUMBER.
CERTIFICATION:THIS IS TO CERTIFY THAT THERE IS NO EXISTING ARTESIAN WELL WITHIN A RADIUSOF 25.00 M FROM THE PROPOSED SEPTIC TANK.
MASTER PLUMBER
PLUMBING JOINTS
FLOOR DRAIN DETAIL
HORIZONTAL TO VERTICAL
4"0 x 4"0
WYE
VERTICAL TO HORIZONTAL
4"0 x 4"0
MAIN VENT STACK
WYE
4" Ø P-TRAP
4" THK. FLOOR DRAIN
R.C. FLOOR SLAB
CONCRETE GROUT
FIN. FLOOR LINE
4"0 x 4"0
WYE
ELBOW
4"0 x 45
ELBOW
4"0 x 45
4"0 x 45
ELBOW
ELEVATION/SECTION
CATCH BASIN DETAIL
NTS
4" THK. CHB
4"Ø PVC PIPE
CONCRETE COVER
0.70
0.10
0.70
0.70m
0.50m
PLAN
0.10m
0.70m
0.10m
0.50m
0.10m
0.10m
4"Ø PVC PIPE
LINE
4"Ø PVC PIPE
LINE
SEPTINC TANK DETAIL
NTS
NTS
ADDRESS: SOGOD, SOUTHERN LEYTE
PREPARED BY:
ENGINEER - 1
GERALD B. HANDAYAN
UNIVERSITY LIBRARY
STAIRS
RAMP
UTILITY ROOM
LOBBY AREA
RECEIPTION
TO
SECOND
FLOOR
hall way 3 m wide
AREA
DISCUSSION AREA
108 SQ.M.
photocopy area
CVM
E - LIB ROOM
MAIN LIBRARY
CO
CO
FD
FD
WC
WC WC
WC
LAV
LAV
CO
UR.
CO
WASTE LINE OUTLET
SEPTIC TANK 1
To Water Source
cb
cb
cb
ds ds
ds dsds ds ds ds ds
cb cb cb cb
cb
cb
Storm Drainage Outlet
FD
FD
UR.
UR.
GROUND FLOOR PLUMBING LAY-OUT
SCALE 1:200M
P
S E A L : PROJECT TITLE: SHEET CONTENT: SHEET #:
2
ADDRESS: SOGOD, SOUTHERN LEYTE
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
3
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
GROUND FLOOR PLUMBING LAY-OUT
ADDRESS: SOGOD, SOUTHERN LEYTE
PREPARED BY:
ENGINEER - 1
GERALD B. HANDAYAN
UNIVERSITY LIBRARY
P
S E A L : PROJECT TITLE: SHEET CONTENT: SHEET #:
3
ADDRESS: SOGOD, SOUTHERN LEYTE
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
3
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
SECOND FLOOR PLUMBING LAY-OUT
STAIRS
RAMP
CONFERENCE ROOM
CHIEF LIBRARIAN'S
OFFICE
PANTRY
STAGE
CONTROL
ROOM
TO
GROUND
FLOOR
STAFF
LOUNGE
TECHNICAL
SECTION
WAITING
AREA
HALL WAY 3M WIDE
HALL WAY 3M WIDE
HA
LL W
AY
3M
W
ID
E
9.475
DRESSING
ROOM
AV MATERIALS &
EQUIPMENTS
STORAGE
ROOM
BINDEREY
SECTION
45°
GS LIBRARY
CO
CO
CO
WASTE LINE OUTLET
SEPTIC TANK 2
To Water Source
KS
UR.UR.
UR.
UR.
WC
WC WC
WC
WC
LAV
LAV
LAV
LAV
SECOND FLOOR PLUMBING LAY-OUT
SCALE 1:200M
ADDRESS: SOGOD, SOUTHERN LEYTE
PREPARED BY:
ENGINEER - 1
GERALD B. HANDAYAN
UNIVERSITY LIBRARY
S
APROVED AS PER PLAN: S E A L : PROJECT TITLE: SHEET CONTENT: SHEET #:
1
SCHEDULE OF FOOTINGS
STRUCTURAL/CIVIL ENGINEER
ANGELO LUMEN M. EWAY
ADDRESS: SOGOD, SOUTHERN LEYTE
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
UNIVERSITY LIBRARY PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
3
PLAN
*NOTE: ACTUAL SIZE OF FOOTING DEPENDS ON
REINF.BOTHWAYS
SECTION
VERTICAL BARS
TIES OR HOOPS
COVER
NATURAL GRADE LINE
ACTUAL SOIL CONDITION AT SITE
W
TYP. FOOTING DETAIL
SCALE 1:30MTS.
WID
TH
LENGTH
TH
IC
H
MIN
. D
EP
TH
=
3
.0
0 M
.
12mmØ VERT. BARS SP. @ .60m &12mmØ HOR.
BARS EVERY 3 LAYERS OR 6"X350 PSI CHB
12mmØ DEFORMED BARS @
REINFORCEMENT
0.15
0.20
0.40
0.35
0.25
0.60
10mmØ TEMP. BARS SP.
@ .60M O.C. BW.
FIN. FLR. LINE
NAT. GRD. LINE
0.13
3" THK GRAVEL BEDDING
WALL FOOTING DETAIL
SCALE 1:30MTS.
FOOTING DESIGN
FOOTINGSIZE (m)
REBARS
SCHEDULE OF FOOTING
F1
F2
3.00 X 3.00 X 0.50
2.50 X 2.50 X 0.50
USE 15 - 28 mm Ø BARS BOTHWAYS
USE 20 - 28 mm Ø BARS BOTHWAYS
FOOTING TO SECOND FLOOR TO ROOF
COLUMN NO.SIZE (cm)
REBARS
SCHEDULE OF COLUMNS
C1 450 x 450
STIRRUPS ( 12mm )
10 - 28 mm Ø
12mm Ø TIES 12 @ 50 mm : NEXT 10 @ 100 mm : REST @ 150 mm
TYPICAL BEAM DETAIL
SCALE: DNTS
@ SUPPORT@ MIDSPAN
ADDT'L TOP BARS CUT 2 BARS STRAIGHT
2 BARS STRAIGHT
ADDT'L BOTTOM BARS CUT
STIRRUPS SPACING
NOTE: NO SPLICE SHALL BE PERMITTED @ MIDSPAN FOR
BOTTOM BARS OR NEAR THE SUPPORTS FOR TOP BARS
MIN. SPLICE LENGTH = 40 X BAR DIAMETER
SCHEDULE OF BEAMS
BEAMS NO.
WIDTH
(mm)
DEPTH
(mm)
STIRRUPS
MIDSPAN REINFORCEMENT
TOP BARS BOTTOM BARS TOP BARS BOTTOM BARS
SUPPORT REINFORCEMENT
600
3 - 25 mm Ø 5 - 25 mm Ø 5 - 25 mm Ø 3 - 25 mm Ø
12 mm Ø STIRRUPS: 15 @ 50mm FROM FACE OF SUPPORT
NEXT 14 @ 100 mm REST @ 150 mm.
B1 300
500
2 - 25 mm Ø 5 - 25 mm Ø 5 - 25 mm Ø 2 - 25 mm Ø
B2 300
600
3 - 28 mm Ø 6 - 28 mm Ø 6 - 28mm Ø 3 - 28 mm Ø
B3 400
SHORT DIR. BAR SPACING
MIDSPAN REINF. ( BOTTOM LAYER )
LONG DIR. BAR SPACING
CONT./DISCONT. EDGE REINF.
( TOP LAYER )
REINF. @ LONG DIR.
RE
IN
F. @
S
HO
RT
D
IR
.
CONT./DISCONT. EDGE REINF.
( TOP LAYER )
MIDSPAN REINF.
( BOTTOM LAYER )
25 mm COVER
SECTION
TYPICAL SLAB DETAIL
SCALE 1:100MTS.
STRUCTURAL DESIGN OF SLAB
SLAB NO.
S1
S2
SHORT DIRECTION BAR SPACING LONG DIRECTION BAR SPACING
THICKNESS
MIDSPAN
( BOTTOM LAYER )
CONTINOUS EDGE
( TOP LAYER )
DISCONTINOUS EDGE
( TOP LAYER )
MIDSPAN
( BOTTOM LAYER )
CONTINOUS EDGE
( TOP LAYER )
DISCONTINOUS EDGE
( TOP LAYER )
12 mm Ø @ 100 mm
12 mm Ø @ 100 mm
150 mm12 mm Ø @ 100 mm 12 mm Ø @ 100 mm 12 mm Ø @ 100 mm
150 mm12 mm Ø @ 100 mm 12 mm Ø @ 100 mm 12 mm Ø @ 100 mm 12 mm Ø @ 100 mm 12 mm Ø @ 100 mm
12 mm Ø @ 100 mm 12 mm Ø @ 100 mm
SCHEDULE OF TIE BEAMS
BEAMS NO.
WIDTH
(mm)
DEPTH
(mm)
STIRRUPS
MIDSPAN REINFORCEMENT
TOP BARS BOTTOM BARS TOP BARS BOTTOM BARS
SUPPORT REINFORCEMENT
600
3 - 25 mm Ø 3 - 25 mm Ø
TB1
300
TB2
TB3
12 mm Ø STIRRUPS: 5 @ 50mm FROM FACE OF SUPPORT
NEXT 6 @ 100 mm REST @ 150 mm.
B4 300
2 - 20 mm Ø 4 - 20 mm Ø 4 - 20 mm Ø 2 - 20 mm Ø
400
FOOTING TO GROUND FLOOR
C0 450 x 45010 - 28 mm Ø
12 mm Ø STIRRUPS: 15 @ 50mm FROM FACE OF SUPPORT
NEXT 14 @ 100 mm REST @ 150 mm.
12 mm Ø STIRRUPS: 15 @ 50mm FROM FACE OF SUPPORT
NEXT 14 @ 100 mm REST @ 150 mm.
12 mm Ø STIRRUPS: 15 @ 50mm FROM FACE OF SUPPORT
NEXT 14 @ 100 mm REST @ 150 mm.
12 mm Ø STIRRUPS: 5 @ 50mm FROM FACE OF SUPPORT
NEXT 6 @ 100 mm REST @ 150 mm.
12 mm Ø STIRRUPS: 5 @ 50mm FROM FACE OF SUPPORT
NEXT 6 @ 100 mm REST @ 150 mm.
12mm Ø TIES 12 @ 50 mm : NEXT 10 @ 100 mm : REST @ 150 mm
5- 25 mm Ø 5- 25 mm Ø
3 - 25 mm Ø 3 - 25 mm Ø
300
5- 25 mm Ø 5- 25 mm Ø
3 - 25 mm Ø 3 - 25 mm Ø
300
5- 25 mm Ø 5- 25 mm Ø
600
600
B5 200
2 - 20 mm Ø 4 - 20 mm Ø 4 - 20 mm Ø 2 - 20 mm Ø
12 mm Ø STIRRUPS: 15 @ 50mm FROM FACE OF SUPPORT
NEXT 14 @ 100 mm REST @ 150 mm.
400
SCHEDULE COLUMNS
SCHEDULE OF BEAMS & TIE BEAMS
STRUCTURAL DESIGN OF SLABS
FOOTING DETAIL & WALL FOOTING DETAIL
TYPICAL BEAM DETAIL
TYPICAL SLAB DETAIL
0.2
5
0.8
0
0.70
+ - 3
.5
0
T-0.18
STAIR DETAIL
SCALE 1:40MTS.
12 mm Ø NOSING
16 mm Ø BARS
T
=
0
.
1
8
16 mm Ø @ 140 mm O.C.
10 mm Ø @ 300 mm O.C.
TEMP. BARS
16 mm Ø @ 130 mm O.C.
NOTE: VERIFY ACTUAL NUMBER OF STEPS
10 mm Ø @ 250 mm O.C.
SEE SPOT DETAIL
T
=
0
.
1
8
16 mm Ø @ 140 mm O.C.
10 mm Ø @ 300 mm O.C. TEMP. BARS
16 mm Ø @ 130 mm O.C.
12 mm Ø NOSING
10 mm Ø @ 250 mm O.C.
16 mm Ø @ 130 mm O.C.
0.30
0.1
8
0.05
SPOT DETAIL
SCALE 1:10MTS.
STAIR & SPOT DETAIL
UNIVERSITY PRESIDENT
A PROPOSED
APPROVED BY:
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
06 - 30- 2015
51177019
12 - 04 - 2015
0141741
at mid-span at support
For TB1,TB2, TB3, & B1
at mid-span at support
For B2
at mid-span at support
For B3
For B4
at mid-span at support
For B5
at mid-span at support
S
A PROPOSED
APROVED AS PER PLAN: S E A L : PROJECT TITLE: APPROVED BY: SHEET CONTENT: SHEET #:
2
FOUNDATION PLAN
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
UNIVERSITY PRESIDENT
PROSE IVY G. YEPES
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
10.000
21.213
10.607
5.303
5.303
3.450
6.325
7.7256.0256.2506.250
6.025 6.250 6.250 6.025
7.275
3.000
6.025
10mm Ø MATTING BARS
SPACED @ 0.60m O.C. B.W.
FOUNDATION PLAN
SCALE 1:200M
F1C1 F1C1 F1C1 F1C1 F1C1 F1C1 F1C1
F2C1 F2C1 F2C1 F2C1 F2C1
F2C1 F2C1 F2C1 F2C1 F2C1
F2C1 F2C1 F2C1 F2C1 F1C1
F2C1 F2C1 F2C1 F2C1 F1C1
F1C1
F1C1
F2C1
F2C1
F2C1
F2C1
F2C1 F2C1
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
ELEV. ON FILL @ +- 0.50m
( CONCRETE SLAB @ 0.10m)
F2C1
F2C1
F2C1
F2C1
7.725
7.275
6.100
3.450
6.025
46.025
6.025
25.000
TB1 TB1 TB1 TB1 TB1 TB1
TB1 TB1 TB1 TB1 TB1 TB1
TB1 TB1 TB1 TB1 TB1 TB1 TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1 TB1 TB1 TB1 TB1 TB1
TB2
TB2
TB2TB2
TB2TB2
TB2
TB2
TB2
TB3
TB3
TB3
10mm Ø MATTING BARS
SPACED @ 0.60m O.C. B.W.
ELEV. ON FILL @ +- 0.50m
( CONCRETE SLAB @ 0.10m)
45°
TB3
TB3
TB1
TB2
F2C0
F2C0
F2C0
F2C0
TB1
S1
S1
S1
B2
B2
B2
B2
TB3
TB2
TB3
B2
B2
3
STRUCTURAL/CIVIL ENGINEER
ANGELO LUMEN M. EWAY
ADDRESS: SOGOD, SOUTHERN LEYTE
06 - 30- 2015
51177019
12 - 04 - 2015
0141741
UNIVERSITY LIBRARY
10.000
21.213
3.450
6.325
7.7256.0256.2506.250
6.025 6.250 6.250
7.275
3.000
6.025
40.000
C1 C1 C1 C1 C1 C1 C1
C1 C1 C1 C1 C1
C1 C1 C1 C1 C1
C1 C1 C1 C1 C1
C1 C1 C1 C1 C1
C1
C1
C1
C1
C1
C1
C1 C1
2ND FLOOR FRAMING PLAN
SCALE 1:200M
6.025
s
RECOMMENDING ISSUANCE :
HEAD STRUCTURAL SECTION
ISSUED BY :
BUILDING OFFICIAL: DATE
DATE
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
7.725
7.275
6.100
3.450
6.025
S2 S2 S2 S2 S2
S2 S2 S2 S2 S2
S2S2
S2
S2
S1 S1 S1 S1 S1
S1
S1
S1
S1
S1
S1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1 B1
B1
B1
B1
B1
B2
B1
B1
B1B1
B1
B1
B1
B1 B1B1
B1
B1
B2
B2
B2
B3
B3
B3
B3
B2
B1
B2
B3
B3
B1
B1
B1
B1
B2
B2
B4 B4 B4 B4 B4
1.275
B1B1B1B1B1
B1B1B1B1B1
B1B1B1B1B1
10.6070
B1B1
B1 B1
B1
B1 B1 B1 B1 B1
S2 S2 S2 S2 S2
S2 S2 S2 S2 S2
B1 B1 B1 B1 B1
B1 B1 B1 B1 B1
S2 S2 S2 S2 S2
S2 S2 S2 S2 S2S2
S2B1 B1 B1 B1 B1 B1 B1 B1
B5
B5
B5B5B5B5B5
B5B5B5B5B5
B5B5B5B5B5
S2S2
3 3
A PROPOSED
APROVED AS PER PLAN: S E A L : PROJECT TITLE: APPROVED BY: SHEET CONTENT: SHEET #:
SECOND FLOOR FRAMING PLAN
DATE :
PTR NO.:
DATE :
TIN NO.:
PRC NO.:
LOCATION: SOUTHERN LEYTE STATE UNIVERSITY - SOGOD MAIN CAMPUS, SOGOD SOUTHERN LEYTE
UNIVERSITY PRESIDENT
PROSE IVY G. YEPES
OWNER: SOUTHERN LEYTE STATE UNIVERSITY
STRUCTURAL/CIVIL ENGINEER
ANGELO LUMEN M. EWAY
ADDRESS: SOGOD, SOUTHERN LEYTE
12 - 04 - 2015
0141741
06 - 30- 2015
51177019
B2
UNIVERSITY LIBRARY
S2
B2