national renewable energy lab 10 june 2015 *presenter · 2015-06-16 · 10 june 2015 *presenter....
TRANSCRIPT
![Page 1: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/1.jpg)
NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC.
Hydrogen Component Validation
Danny Terlip*, Kevin Harrison, Michael PetersNational Renewable Energy Lab10 June 2015
*presenter
TV-019
This presentation does not contain any proprietary, confidential, or otherwise restricted information.
![Page 2: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/2.jpg)
2
Overview
Project start date: 10/2012Project end date: 10/20151
D - Lack of Performance Data (detailed compressor reliability data and analysis)
Timeline Barriers
• PDC Machines (CRADA)• XCEL Energy (CRADA)
PartnersTotal DOE funds received to date: $758kFY14 DOE funding: $265kFY15 planned DOE funding: $300k
Budget
1 project continuation and direction determined annually by DOE
![Page 3: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/3.jpg)
3
Objective and Relevance
• Goal – Generate data and study compressor operation to determine common failure modes and performance in variable conditions
• Impacto Improve compressor operation and
reliabilityo Generating performance data on
compressor operationo Highlighting compressor failures and
consequenceso Work with manufacturer to improve
design and increase reliability
Compressors are #1 in downtime and maintenance event count accounting for 1/3 of maintenance hours at stations
Compressors
NREL CDP INFR 21 – Created Oct 14
![Page 4: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/4.jpg)
4
Approach
• Collect data on 4 compressors and ambient conditions while operating within manufacturer’s recommendationso Integrate compressors with hydrogen production and fueling station
• Current Scopeo Extensive data collection on temperature, pressure, etc. for DUT1 onlyo Failure data collected for DUT2 and 3
Parameter DUT1 DUT2 DUT3 DUT4
Duty Cycle 20 hrs/day As Needed As Needed As Needed
Max DischargePressure (psig) 6,000 6,000 20,000 14,000
Flow Rate (SCFM1) 25 18.8 5 140
Start of Operation April 2014 December 2014 January 2015 Exp Sept 20151) 60oF, 1 atm
![Page 5: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/5.jpg)
5
Approach
• Deep dive analysis into failureso Leverage NREL’s chemical analysis capabilities for contaminantso Corroborate failures with similar compressors operating at NRELo Compare reliability and performance data with data collected through
NFCTEC on compressors in the fieldo Present analysis to manufacturer on failure causes for DUT1 only
www.hutton.ac.uk
![Page 6: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/6.jpg)
6
Accomplishments and Progress
• Key Findingso Compressor Performance and Reliability Datao Seal Weakness is the Main Failure Mechanismo Preemptive Detection of Catastrophic Seal Failureo Repairs of Most Common Failures are Expensive and Time
Consuming
Seal FailureOn frame hoist
![Page 7: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/7.jpg)
7
Accomplishments and Progress: Data Collection
• One year of operational data collected for DUT1
0100200300400500600700800
19-Mar-14 8-May-14 27-Jun-14 16-Aug-14 5-Oct-14 24-Nov-14 13-Jan-15 4-Mar-15
Compressor Hours of Operation
Shakedown
CV Seal Failure
RV Work
1st Stage Seal Failure
PT Failure
2nd Stage Seal Failure
Parameter DUT1
Operating Time 753 hours
Start/Stops 81
Amount of H2 Compressed 1808 kg
Number of Major Failures 4
Mean Time Between Failures 49 days
Calculated Flow Rate 3.7 kg/hr
Average Efficiency1 3.54 kWh/kg[1] Constant suction pressure, pf=0.8, includes coolant pump and radiator power consumption (1.86 kW)
RV – Readiness VerificationPT – pressure transducerCV – check valve
![Page 8: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/8.jpg)
8
Accomplishments and Progress: Data Collection
• Power consumption found to be consistent for DUT1
Full YearPavg = 13.1 kW; SD = 0.6 kW; m = 200 W/ksi
Single DayPavg = 12.9 kW; SD = 0.5 kW
Discharge pressure: [2750, 2980] psig
Varying ambient temperature Varying discharge pressure
![Page 9: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/9.jpg)
9
Accomplishments and Progress: Failure Mode Analysis
• Five seal failures have occurredo Four in compressor headso One on a check valve seal
• Consistent with NFCTEC CDP24
Seal Failure 1 Seal Failure 2
Compressor assembly (6) are seals
![Page 10: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/10.jpg)
10
Accomplishments and Progress: Repair Cost
Failure Repair Time
People Required Parts Cost Parts Lead time Uncommon Tools
Required
CV Seal <1 hour 1 $20 3 weeks Torque wrench, long pick
1st Stage Seal 3 hours 2 $1000 6 weeks
Torque wrench,breaker bar, hoist,
lint free wipes
2nd Stage Seal 4 hours 2 $1,200 6 weeks
Large torquewrench, large
breaker bar, hoist, lint free wipes
Minor Leaks <1 hour 1 N/A N/A Torque wrench,
leak detector
Downtime can be minimized if spare kits offered by compressor manufacturers are on hand
![Page 11: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/11.jpg)
11
Accomplishments and Progress: Preemptive Detection
• Monitor leak detection circuito Alarms are set at levels above what may indicate the
beginning of a failureo Early action may prevent contamination and downtime
Leak detection circuit indicating the beginning of a seal failure
![Page 12: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/12.jpg)
12
Accomplishments and Progress
• Suggested Improvementso Generate More Performance and Reliability Datao Overpump Valve Setting Monitor
Overpump valve schematic
Overpump valve
Temporary pressure monitor
![Page 13: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/13.jpg)
13
Accomplishments and Progress
• Suggested improvementso Alternate Testing Schemeso Contaminant Analysis
Contaminant in hydrogen line FTIR contaminant analysis
![Page 14: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/14.jpg)
14
Accomplishments and Progress:Responses to Previous Year Reviewers’ Comments
• Technoeconomic analysis of failures lackingo Documented for each failure
– Time for repairs, assuming parts are on hand– Parts– Uncommon tools– Man-power
o Impacts on station availability are variable– Commercial station utilization is low– Station configuration can allow for operation without compressor
• “Very few operating hours for how much time project has been ongoing”o Installation problems were solvedo Operating time significantly increased, but still more limited than commercial
• “It is not clear if it will be possible to reduce the maintenance time and associated costs.”o Leak detection circuit can pre-emptively indicate a failure and drastically
reduce maintenance timeo A monitor on the overpump valves can warn of drift and corrections can be
made before failures occur
![Page 15: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/15.jpg)
15
Collaborations
• Externalo PDC Machines Inc. (CRADA) – Equipment, technical support, project direction
o XCEL Energy (CRADA) - Equipment to build hydrogen production and fueling station
o Proton OnSite (informal) – Electrolyzer for hydrogen production
o PNNL (info sharing) – advanced diaphragm compressor modeling
o Vehicle OEM (informal) – testing FCEV technology
• Internalo Renewable Electrolysis (PD031) – Integrated system development and testing
![Page 16: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/16.jpg)
16
Proposed Future Work
• DUT1o CRADA ends 15 October 2015o NREL discussing next steps with CRADA partner
• DUT2, DUT3 and DUT4o More operating hourso Collect more data and publish results for multiple hydrogen
compressor technologieso Power meters for DUT2 and 4 neededo Comparison of MTBF and failure modes
• Correlate contaminant analysis results o Effects on fuel cellso Source of contaminant
![Page 17: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/17.jpg)
17
Summary
• Four compressors are currently in operation at NRELo DUT1: Extensive data collection and purposeful testingo DUT2-4: Failure data and operating hours o All are integrated into hydrogen stations that fill FCEVs
• Performance and reliability data is compared to NFCTEC CDP• Key findings and recommendations determined from deep
dive failure analyses are given
![Page 18: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/18.jpg)
Technical Back-Up Slides
![Page 19: National Renewable Energy Lab 10 June 2015 *presenter · 2015-06-16 · 10 June 2015 *presenter. TV-019. ... CV Seal Failure RV Work 1 st Stage Seal Failure PT Failure 2 nd Stage](https://reader034.vdocument.in/reader034/viewer/2022050309/5f71138bce578d4ee02aeb10/html5/thumbnails/19.jpg)
19
Power Measurement• Variable power consumption
• Constant discharge pressure 4500 psig• Current (yellow) fluctuation [17, 33] A• Voltage (cyan) fluctuation highly stable• Power fluctuation [14, 27] kVA• Average power factor [0.28, 0.99]
• Averaging required for long term data collection
VIDEO
150 ms