net sparrow adsl z60 tester

Upload: frederick-tsede

Post on 08-Apr-2018

243 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    1/31

    Ne

    tSparrowADSLZ60Tester

    1

    NetSparrowADSL

    Z60Tester

    UserManual

    NetSparrowADSLZ60Tester

    2

    Introduction

    Thankyouverymu

    chforpurchasingourproduc

    t.

    ThisUsersManua

    lcontainsusefulinformationa

    boutthefunctions,

    installationandwiringprocedures,operationpr

    ocedures,andthe

    troubleshootingofth

    eNetSparrowADSLZ60Teste

    r.Toensurecorrect

    use,pleasereadth

    ismanualthoroughlybeforeo

    peration.Keepthis

    manualinasafepla

    ceforquickreferenceintheeve

    ntaquestionarises.

    StructureoftheMa

    nual

    ThisUsersManualconsistsofthefollowing8chapters.

    Chapter

    Title

    Description

    1.Summarization

    Generalintroduction

    aboutNetSparrow

    ADSLZ60Tester

    2.CheckingtheCon

    tentsof

    Introducethecontentsofthepackage.

    thePackage

    3.Safety

    Describesthepreca

    utionstobetaken

    inordertousetheNetSparrowADSL

    Z60Testersafely.

    4.Noticeinoperationandusing

    Introducesomenoticeinoperation

    andusing.

    5.Systemconfiguration

    Givesadiagrama

    ndstructure

    andquickreference

    introductionoftheNetSparrowADSL

    Tester.

    6.FunctionandSp

    ecification

    Givethespecificationsand

    functionsoftheinstrument.

    7.Operation

    Givetheinstruction

    stoADSLZ60.

    8.

    Analyzingand

    Describeshowto

    solvesmall

    Solutionforfaults

    faultofNetSparrow

    ADSLZ60Tester

    byyourself.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    2/31

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    3/31

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    4/31

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    5/31

    Ne

    tSparrowADSLZ60Tester

    9

    Please

    dontputtheinstrumentunder

    thestrongdirectsunlightand

    neartheoriginofheat.Orelse,therew

    illbebadaffecttocircuit.

    Conde

    nsationmayoccuriftheinstrumentismovedtoanotherplace

    wheretheambienttemperatureishigher,orifthetemperatureifthe

    roomchangesrapidly.Inthiscase,lettheinstrumentadjusttothe

    newen

    vironmentforatleastonehourb

    eforeusingtheinstrument.

    Using

    theinstrumentnearstrongmagneticfieldsourceswillhave

    adverseaffectsontheinternalcircuitoftheinstrument.

    Ifyoua

    reusingaportablephonetotransmitmeasureddata,move

    theportablephoneatleast1m

    awayfrom

    theinstrumentand

    MeasuringCables.Themeasureddatacanreceiveundesirable

    effects

    from

    theelectromagneticwavegeneratedbytheportable

    phone.

    5.Syste

    m

    configurationandquickreference

    5.1Syst

    em

    configuration

    NetSparrowADSLZ60Tester

    10

    xDSLPortForuserxDSLlinelinkandDMMtestlink.

    LANPort

    Ethernetport.

    xDSLMod

    emDifferentModemcanperformdifferentfunction.

    MainlyincludeA

    DSL,

    ADSL2,AD

    SL2+,READSL,VDSL,etc.

    USB

    HOS

    TLinkUSB

    equipment,key

    board,mouseand

    memorykey.

    5.2Quickreference

    5.2.1NetSparrowADSLZ60TesterFrontP

    anel

    IndicatorLigh

    ts

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    6/31

    Ne

    tSparrowADSLZ60Tester

    11

    PowerIndicatorLigh

    t

    Redcolor,powersupplied

    EthernetIndicatorLight:

    Greencolor,normalEthe

    rnetconnection

    Shininggreencolor,Ethe

    rnetdatatransmission

    xDSLLINKIndicator

    Light

    Shininggreencolor,xDSLModembeingconnected

    Greencolor,xDSLconne

    cted.

    xDSLACTIndicatorLight

    Shininggreencolor,xDSLdatatransmission.

    Button

    s

    ON

    Switchontester.

    OFF

    Switchofftesterwhenthereareabnormalphenomena,

    suchastesterdeadorslowrunspeed.

    RESET

    Resetsystemwhenthere

    isanabnormal

    phenomenonoccurs.

    L

    CDDisplay

    TFTtruec

    olorscreen,240320lattice,touchingscreen.Pleasenot

    touchitwithotherhardthings.

    5.2.2Net

    SparrowADSLZ60Tester

    Upside

    Touchingstick

    Useittopointiconsfromdisp

    layscreentohaveoperation.

    NetSparrowADSLZ60Tester

    12

    Insertitintoleftupcorneroftesterwhe

    nitisnotused.

    Ethernetport1

    ItisR

    J45port.ItisforlinkingEthernetnetworkcordor

    BroadbandIPwithRJ45networkline

    plugs.Itisforcross

    networkcordlink.Whenconnected,the

    correspondinglight

    willbe

    bright.

    Ethernetport2

    ItisRJ

    45port.ItisforlinkingEthernet

    networkcordor

    BroadbandIPwithRJ45networklinep

    lugs.Itisfordirect

    networkcordlink.Whenconnected,the

    correspondinglight

    willbe

    bright.

    xDS

    Lport

    ItistheportforbothxDSLlineandD

    MMtest.Thereare

    twoco

    nnectionways.

    Oneis

    standardRJ11port.ItisforlinkingRJ11port.

    Theotheroneisred&blackport.Itisforlinkingtestcords.

    These

    twoportsareconnectedinside

    ofthetester.User

    canus

    eanyone.

    5.2.3NetSparrow

    ADSLZ60TesterDowns

    ide

    USB

    Port

    Tolink

    memorykey,keyboardormouse.Whentolink

    memorykey,itisusedtoupgrade

    testersoftwareor

    exchangerecordfilewithtester;whentolinkkeyboard,itis

    usedasnormalkeyboardtotypew

    ords;whentolink

    mouse

    ,itisusedasnormalmousetocarryoutoperation.

    Cha

    rgerPort

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    7/31

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    8/31

    Ne

    tSparrowADSLZ60Tester

    15

    Webpagebrowsingfunction.

    6.3DMM

    test

    Testuser

    lineAC/DC

    Voltage,LoopResistance,Capacitanceand

    Insulation.

    Unit

    TestRa

    nge

    Error

    0--100DC

    2%

    100--20

    0DC

    5%

    V

    200--40

    0DC

    5%

    0100

    AC

    2%

    Voltage

    V

    100--40

    0AC

    5%

    0100

    3%

    1005

    00

    3%

    5002

    000

    2%

    Loop

    Resistan

    ce

    2000

    20K

    2%

    010

    2nF

    Capacitance

    nF

    1010

    00

    2%

    01.0

    0.1M

    Insulation

    M

    1.050

    10%

    6.4Modem

    emulation

    PerformMODEMEmulationfunctiontodialandlogoninternettocheck

    faults.

    6.5File

    management

    Browsetes

    trecord,transferrecordintoPC

    ormemorykey.

    6.6Help

    Thispartin

    cludesthesystemupgrade,fun

    ctionset,recalibrateanduse

    notes.The

    systemsoftwarecanbeupgradebyEthernetormemorykey.

    NetSparrowADSLZ60Tester

    16

    6.7Otherspec

    ifications

    7.Operation

    7.1Switchon/off,restart

    (1)Switchon:Press

    ONbuttonintherightofinstrum

    enttoswitchonthe

    tester.After7seconds,operationwindowwillbedisplayed.

    (2)Switchoff:PointCloseSystem

    iconfromoperationinterface,point

    OKtoswitchoffthe

    testerfromthewindowdisplayed.

    (3)OFFbutton:Pre

    ssitintherightoftheinstrumenttoswitchoffthe

    testerwhen

    there

    is

    abnormaloperation

    phenomenon

    occurred.

    Suggestion:Switchofftesterthroughsystem.

    (4)RESETbutton:Pressittorestartthetesterwhenthereisslowrun

    speedortesterdeadphenomenon.

    7.2Operationinterfacedescription

    Memorycapacity:

    20M

    Display:

    240320LCD,touchscreen,

    Windowsinterface

    PowerSupply

    External:Fromadapter,9.6VDC

    Internal:Rechargeable7.4V21

    00mAHLi-ionbattery

    BatteryDuration:

    8hs(exceptModemstatus)

    Dimensions/Weight:

    176mm130mm60mm/0.7kg(W

    ithbattery)

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    9/31

    Ne

    tSparrowADSLZ60Tester

    17

    Themaino

    perationinterfaceisdividedinto

    3parts.

    7.2.1Statebar

    Battery:

    Showbatteryenergy.Itisdivide

    dinto3parts.Pleasecharge

    itsoonwhe

    nall3partsareempty.

    Time:Showthecurrenttime.Pointitto

    setdateandtime.

    Point

    to

    enterintoHELPwindow.

    Youcanch

    angethecurrentdateandtime

    bytouchingstickandpress

    Applykeytosaveit.

    7.2.2Fun

    ctionbar

    Pointdifferenticontohaverelevanttestoperation.

    7.2.3Too

    lsbar

    PPPoEDisconnectionicon.

    NetSparrowADSLZ60Tester

    18

    Whendialisok,

    changeto

    .Point

    ,todisconnect

    PPPoEconnectionfromwindowdisplayed.

    InputPanel

    PointtodisplayorhideInputPanel.

    Toinputlowercase,numberandinterpunction.

    PointShifttoinpu

    tcapitalcharacterandspecia

    lsymbols,partsof

    interpunction.

    Homepage

    Pointittoreturnmainoperationinterface.

    Back

    Pointittoreturnupp

    erinterface.

    7.3xDSLtest

    TovalidateDUN(DIAL-UpNetworking)andtestxDSLlineperformance

    throughinsideMode

    m.

    xDSLtestIncludes

    physicallayertest,modemparameterset,PPPoE

    properties,PPPoE

    dial,network

    layertest,webpage

    browsing,

    LOOPBACK,FTPclientandwebpagespeedtestfunctions.

    Thefunctioncanem

    ulatetheusersideequipmenttohavePPPoEdial,

    networktestandwebpagebrowsing.Anditalsocanjudgethetesting

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    10/31

    Ne

    tSparrowADSLZ60Tester

    19

    linequality

    byphysicallayerparameter

    s.Itcanexcludethefault

    becauseof

    usersideequipment.

    Twokindsoflinelinkdiagram:

    Thefunctio

    ncanvalidatewhethertheuserlineisgoodandalsocan

    solvethefaultfromuserModemanduser

    PCbydataparametersfrom

    userline.

    LinkxDSL

    pairintoRJ11portdirectlyorth

    roughxDSLseparator.Point

    xDSLT

    esttoenterintooperationwindow.

    Pointdifferenticonstohaverelevanttestoperation.

    ThestepsforlogonwebpagebyxDSLline,

    likefollowing:

    SetModem

    parameter(VPI/VCI)SetPP

    PoEPropertiesSecurity

    PPPoED

    ialHavePPPoEdialWhentheLinkindicatorisbright,Type

    username

    andpasswordbrowsewebpageorhavenetworklayer

    test.

    Ifitneeds

    totestpossibilityofconnectio

    nbetweenModem

    andOE

    (OfficeEnd

    ),nosetstepsneedtobedone.

    IfthexDSLActindicatorlight

    NetSparrowADSLZ60Tester

    20

    isbright,thephysicallayertestparametersneedto

    bechecked,please

    pointit.

    7.3.1Physicalla

    yertest

    Performthetestofthephysicallayer.

    Point

    toente

    rthephysicallayertestwindow.

    7.3.1.1Physical

    layerparameters

    TestxDSLlinephysicallayerparameter.ItincludesxDSLconnectingState,

    connectingMode,U

    p/DownStreamSpeed,NoiseMargin,Attenuation,

    OutputPower,CRC

    Error,CRCError,HECError,FE

    CError,OCDError,

    NCDErrorandChannelBitpic.

    1

    Point

    PhysicalLayerTest,thePrepa

    ringtest

    environmen

    tWindowwillbedisplayed,plea

    sewaitforseconds

    tilltoenterin

    tooperationwindow.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    11/31

    Ne

    tSparrowADSLZ60Tester

    21

    ADS

    L2+physicallayer

    AD

    SL2+physicallayer

    parameters1

    parameters2

    ADSLPhysicallayer

    parameters

    Everypara

    metervaluewillbedisplayed.T

    heywillberefreshedinreal

    timetosho

    wthecurrentstate.TheconnectionprocessofxDSLlineand

    OE(Office

    End)equipmentwillbedisp

    layedfrom

    Statebar(Idle,

    Handshake

    ,Training,andShowtime);the

    currentconnectionmodewill

    bedisplaye

    dfromModebar.

    A.Curren

    tmodeinterpretation

    Idle:noconnectionortryingtodo

    connection.

    H

    andShake:performhandshaking.

    D

    iscovery:theOEDSLAMisfoun

    d.

    Training:inthetrainingofthecon

    nection.

    S

    howtime:RemoteDSLAMconnected.

    NetSparrowADSLZ60Tester

    22

    B.Connectionm

    odeinterpretation

    ADIADSLADImode

    G.DMTADSLG.DMTprotocolmode,inac

    cordancewithITU-T

    G992.1sta

    ndard

    G.LITEAD

    SLG.LITEprotocolmodeinac

    cordancewithITU-T

    G992.2sta

    ndard

    T1.413AD

    SLT1.413protocolmodeinaccordancewithANSI

    T1.413issue1&Issue2standard.

    G.DMT.BIS

    ADSL2G.DMT.BISprotocolm

    odeinaccordance

    withITU-T

    G992.3standard

    G.DMT.BIS

    PLUSADSL2+G.DMT.BISPLU

    Sprotocolmode

    inaccordancewithITU-TG992.5

    C.Physicallayerparametersinterpretation

    Activatetimes:Itcountsthemodemactivatedtimesfromthebeginning

    ofthetest.Oncethe

    modemisactivatedthenumberwilltallyup.

    Testtime:Itwillsho

    wthetesttimeafterthemodem

    isinitialized.

    (2)PointChannelBitpic,theChannelBitpicwill

    bedisplayedinred

    color.

    Nowtheusercanse

    ethebitvalueofcurrentconnectionwhichcanalso

    bedisplayedinmap.Ifuserneedstoseetheresults

    intextyoucanpoint

    the

    thenthefollowingwindoww

    illbedisplayed.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    12/31

    Ne

    tSparrowADSLZ60Tester

    23

    (3)PointCanceltoclosebitmapwindow.

    (4)PointC

    ancelfrom

    PhysicallayerTestwindow,onetestrecord

    windowwillbedisplayed.

    (5)PointCancelifyoudonotsaverecord.

    (6)PointOKifyousavetherecord.

    Thedefaultfilenameislinexxxx-xxx.phy,inwhichxmeansthe

    number.Us

    ercanmodifythelinenumbera

    stelephonenumber.

    7.3.1.2Noisecurve

    Itusedtob

    rowsetherealtimenoisemargincurve.

    Point

    noisemarginiconitwilldispla

    ythefollowingnoisecurve

    picture.

    NetSparrowADSLZ60Tester

    24

    Thispartcontainsupstreamnoisemargincurveanddownstreamnoise

    margincurve.Theyarereflectsthenoisemarginvariesasthetimepass.

    Ifuserpressupstreamordownstreamattheto

    pofthewindowthe

    belowrealtimepictu

    rewillchange.

    7.3.2Modem

    parameterset

    ThefunctionistomodifyxDSLModemparameters,

    VPI/VCIvalues.

    (1)Point

    MODEMParametertoenterintooperationwindow.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    13/31

    Ne

    tSparrowADSLZ60Tester

    25

    ADSL2+M

    oduleSettingWindow

    AD

    SLModuleSettingWindow

    (2)TheVPI/VCIparameterswhichwerese

    tbeforewillbedisplayed.Ifit

    needstob

    emodified,typenewVPI/VCIvaluefromVPIandVCIbar.

    PointOK,a

    ndtheModemVPI/VCIwillbes

    et.

    WhentheMODEMisADSL2+,italsocan

    besetasADSLcompatible

    mode.

    ADSL2+M

    ode:ItisstandardADSL2+mode.Thecurrentconnection

    modecanbeautomaticallychosenaccordingtoOEmode.

    ADSLCom

    patibleMode:TheADSL2+connectionmodeisunavailable

    undersuch

    mode.

    IftheMOD

    EMModeismodifiedasanoth

    erkindofit,pleaseexitthe

    xDSLTestandre-enteritagain.

    Notice

    (1)IntheA

    DSL2+Module,iftheMODEM

    Modeismodifiedasanother

    kindofit,pleaseexitthexDSLTestandre-enteritagain.Otherwise,the

    NetSparrowADSLZ60Tester

    26

    MODEModifyingwillnotbeeffective.

    (2)TheVPI/VCIparameterswhichweresetbeforewillbedisplayed.Ifit

    needstobemodifie

    d,typenewVPI/VCIvaluefromVPIandVCIbar.

    PointOK,andtheM

    odemVPI/VCIwillbeset.

    7.3.3PPPoEproperties

    CheckandmodifyP

    PPoEDialPropertiesset.

    (1)Point

    PP

    PoEPropertiesicontoentertheoperationwindow.

    PointSecuritySettingstoenterintooperationwindow.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    14/31

    Ne

    tSparrowADSLZ60Tester

    27

    ChooseUn

    encryptedpassword(PAP)andPreviewusernameand

    password,cancelotheroptions.PointO

    K

    tosetit.Point

    from

    Connectio

    nwindowtoclosethesewindow

    s.

    . Notice

    Ifthere

    iswrongPPPoEset,PPPoEdialwillbefailed.Pleasebe

    carefultom

    odifyPPPoEproperties.

    Allotherparametershavealreadybeenwellset.Pleasedonot

    modifyord

    eleteanythingexceptPPPoEto

    avoidfailuseofnetworkcard

    andPPPoE

    Dial.

    7.3.4PPP

    oEdial

    TobuildPP

    PoEDialconnectionthroughinsidexDSLModem.

    (1)Point

    PPPoEDialtoenterintooperationwindow.

    (2)Typeus

    ernameandpasswordfromtheUserNameandPassword

    NetSparrowADSLZ60Tester

    28

    bar.Thesavepas

    sworddefaultoptionisselectedandcannotbe

    revised.Pleasekee

    pDomaincolumnbeblank,otherwise,thePPPoE

    Dialingwillbefailed.

    (3)KeepDomainbeblack.PointOK,displayslikefollowing:

    (4)AfterPPPoEDialconnected,

    willbecome

    as

    ,ifitneeds

    tobedisconnected,

    point

    ,theconnectionwindowwillbedisplayed,

    pointCanceltodisc

    onnectit.

    Note:1.Youcando

    PPPdialaftertheLINKindicatorislightallthetime,

    otherwisePPPdialin

    gwillfail.

    2.PPPsafetyp

    ropertyparametersshouldbesetbyrunners

    cryptographicway,otherwisePPPdialingwillfail.

    3.Theusernam

    eandpasswordmustbematch

    edwiththecable,

    otherwisePPPdialingwillfail.

    7.3.5Networkla

    yertest

    AfterthePPPoE

    DialconnectionthroughinsideModem,tohave

    NetworkLayerTest(Ping,Ipconfig,TracertandRoutetest).

    (1)Point

    Netw

    orkLayerTesttoenterintoope

    rationwindow.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    15/31

    Ne

    tSparrowADSLZ60Tester

    29

    (2)Pointdif

    ferenticontohaverelevanttestope

    ration.

    7.3.5.1PINGtest

    (1)PointPINGTesttoenterintooperation

    window.

    (2)TypeIP

    addressordomainnameintoD

    estinationbar.

    (3)Choose

    thedatapackagesizeinthedatapackagesizebar.

    (4)Choose

    PingtimesfromTesttimes.

    ThedefaultPingtimesis5

    times.

    (5)PointOK,thePingtestprocesswillbed

    isplayedindynamic.

    (6)WhenthePingtestresultwindowdispla

    yed,point

    whichisinthe

    righttopcornerofscreentoclosethew

    indow.

    7.3.5.2IP

    CONFIGtest

    ThecurrentTCP/IP,networkconfigurationv

    alue,DHCPandDNSsetwill

    bedisplaye

    d.

    (1)PointIP

    CONFIGTesttoenterintooperationwindow.

    NetSparrowADSLZ60Tester

    30

    (2)ChooseIpconfig

    ParameterfromIpconfigParameterbar,pointOK

    tohaveIpconfigtest.

    (3)Onetestresultw

    indowwillbedisplayed.Point

    fromtherighttop

    cornerofscreento

    closethewindowaftertheIpc

    onfigresultwindow

    displayed.

    7.3.5.3ROUTEtest

    (1)Point

    ROUTETesttoenterintooperation

    window.

    (2)ChooseRouteP

    arameterfromParametersetandpointOKtohave

    Routetest.Thedefa

    ultoneisPrint.

    (3)OneRouteresultwindowwillbedisplayed.Point

    fromtheright

    topcornerofscreen

    toclosethewindowaftertheRouteresultwindow

    displayed.

    7.3.5.4TRACERT

    test

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    16/31

    Ne

    tSparrowADSLZ60Tester

    31

    (1)Point

    TRACERTTesttoenterintooperationwindow.

    (2)Typead

    dressorwebaddressinDestin

    ationbar,chooseparameter

    fromTrace

    rtbar,pointOKtohaveTracertTest.

    (3)OneTracertresultwindowwillbedisplayed.Point

    from

    theright

    top

    corner

    ofscreen

    to

    closethewindowa

    ftertheTracertresultwindow

    displayed.

    7.3.6Web

    pagebrowse

    Logonand

    browsewebpage.

    (1)Point

    WebpageBrowsetoopenw

    ebpagebrowser

    NetSparrowADSLZ60Tester

    32

    (2)PointAddressb

    ar,theInputPanelwillbedisplayed.

    (3)TypewebsiteaddressandpointEnterusin

    ginputpanelto

    logonthewebsite

    .

    7.3.7LOOPBACK

    test

    PingTestforF5OAMofATMlayertoverifyATMlayerconnection.

    Point

    Loopb

    ackTesticontoenterintooperationwindow.

    ChoosePVCacces

    s,pointTesttohaveitsLOOPBACKtest.Thetest

    resultwillbedisplay

    ed.TestResult:Successorfail

    Notice:

    ThePVCchosenby

    usershouldbethesameasline

    VPI/VCI,otherwise,

    theLoopbackTestw

    illbefailed.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    17/31

    Ne

    tSparrowADSLZ60Tester

    33

    7.3.8FTP

    client

    ThetestercanprovidetheFTPclientfunctiontest.

    (1)Point

    FTP

    ClienticontoopenthefollowingFTPclient

    window.

    (2)FilltheIPaddressofthewebsitewillbe

    testedintotheaddressbar

    andalsotheusernameandpasswordthenpointtheconnectkeytoenter.

    (3)PointtheparameterkeytoselecttheFT

    Pmodeandport.

    (4)Theleft

    blanketisthelistingoftheLocalcatalogwhiletherightoneis

    thelistingo

    ftheremotecatalog.Andtheco

    nnectionstatewillbe

    displayeda

    tthedownleftcorner.

    (5)Point

    toentertheFTPconne

    ctionparametersetting.

    NetSparrowADSLZ60Tester

    34

    Theusercansetthe

    portandconnectionmode

    7.3.9Webpages

    peedtest

    Thewebpagespeed

    testisusedtovalidatethenetw

    orkflux.

    (1)Point

    WebSpeedtesticontoopenthesp

    eedtestwindow.

    (2)Inputthewebsite

    IPaddressintotheaddressbar.Thenpressthetest

    keytostartthewebsitespeedtest.Theresultswillbedisplayedinform

    ofpictureortextacc

    ordingtheoption.

    Resultinpicture

    Resultintext

    Attentions:

    1.InLANtesttheu

    sershouldsetthegatewayand

    DNSwhileinxDSL

    testcancelingthega

    tewayandDNSsettingisnecessaryandconnected

    throughPPPoE.

    2.Pleasedonotice

    thatfilltherightaddressintotheaddressbar.Itcan

    notgetgoodeffectwhiletestingthewebsitewhichisusedtomake

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    18/31

    Ne

    tSparrowADSLZ60Tester

    35

    addressjum

    pattheserver.

    7.4LAN

    test

    ForEthernetandBroadbandIPnetworktes

    t.

    EmulatetesterasuserPCtohavePPPoE

    DUN(Dial-UpNetworking).It

    includesN

    etworkCardProperties,PPPoEProperties,PPPoEDial,

    NetworkLa

    yerTestPing,Ipconfig,RouteandTracert,FixativeIPScan,

    WebpageB

    rowse,FTPclientandwebpage

    speedtestfunctions.

    (1)Point

    LANTesttoenterintoopera

    tionwindow.

    (2)Pointdifferenticontohaverelevanttest

    operation.

    7.4.1Net

    workcardproperties

    Checkandmodifynetworkcardproperties,includingIP

    address,

    gatewayan

    dDNS.

    NetSparrowADSLZ60Tester

    36

    (1)Point

    Netw

    orkCardtoenterintooperation

    window.

    (2)UsercanmodifyIPaddress,gatewayandDNSvaluefrom

    IP

    address,DefaultandDNSbarseparately.PointOK

    tosaveitandpoint

    Canceltocloseit.

    7.4.2PPPoEproperties

    CheckandmodifyP

    PPoESecuritysettingsofPPPo

    EProperties.

    (1)Point

    PP

    PoEPropertiestoenterintoop

    erationwindow.

    (2)PointSecurityS

    ettingstoenterintooperation

    window.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    19/31

    Ne

    tSparrowADSLZ60Tester

    37

    (3)Choose

    UnencryptedPassword(PAP)andPreview

    username

    andpassw

    ord,cancelotheroptions.Point

    OKtosetit.

    (4)Point

    fromConnectionwindowtocloseit.

    Notice

    IfthereiswrongPPPoEset,PPPoEdialwillbefailed.

    PleasebecarefultomodifyPPPoEproperties.

    Allotherparametershavealreadybeenwellset.

    PleasedonotmodifyordeleteanythingexceptPPPoEto

    avoidfailuseofnetworkcard

    andPPPoEDial.

    7.4.3PPP

    oEdial

    BuildPPPo

    EDialthroughoutsideModem.

    (1)PointPPPoEDialtoenterintooperationwindow.

    (2)Typeus

    ernameandpasswordfromUs

    erNameandPasswordbar

    separately.

    ChooseSavepasswordtosaveit.Thesavepassword

    optionisde

    faultandcannotberevised.

    NetSparrowADSLZ60Tester

    38

    (3)KeepDomain

    barbeblack.PointOK

    toh

    aveDUN

    (Dial-Up

    Networking).

    (4)AfterPPPoEDialconnected,

    willbecomeas

    ,ifitneedsto

    bedisconnected,point

    ,theconnectionwindowwillbedisplayed,

    pointCanceltodisc

    onnectit.

    Note

    IfyouwanttodoPPPoEdialthroughtheLANport,andusethetester

    tologinthewebpage,youshouldensureallitemsofDNSandthe

    defaultgatewayofnetcardare0.0.0.0,Otherwise,youcandoPPP

    dialsuccessfully,

    butcannotbrowsethewebpage.

    7.4.4Networkla

    yertest

    AfterthePPPoE

    DialconnectionthroughinsideModem,tohave

    NetworkLayerTest(Ping,Ipconfig,TracertandRoutetest).

    (1)Point

    Netw

    orkLayerTesttoenterintoope

    rationwindow.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    20/31

    Ne

    tSparrowADSLZ60Tester

    39

    2P

    ointdifferenticontohavereleva

    nttestoperation.

    7.4.4.1PINGtest

    1

    Poin

    t

    PINGTesttoenterinto

    operationwindow.

    (2)TypeIP

    addressordomainnameintoD

    estinationbar.ChoosePing

    timesfrom

    Testtimes.ThedefaultPingtim

    esis5times.

    (3)Selectd

    atapackagesizeinthedatapackagesizebar.

    (4)PointOK,thePingtestprocesswillbed

    isplayedindynamic.

    (5)WhenPingtestresultwindowdisplayed,point

    whichisinthe

    righttopco

    rnerofscreentoclosethewindow.

    7.4.4.2IP

    CONFIGtest

    ThecurrentTCP/IP,networkconfigurationv

    alue,DHCPandDNSsetwill

    bedisplaye

    d.

    NetSparrowADSLZ60Tester

    40

    (1)Point

    IPC

    ONFIGTesttoenterintoIpconfigtestwindow.

    (2)ChooseIpco

    nfigParameterfromIpconfigP

    arameterbar,point

    OKtohaveIpco

    nfigtest.

    (3)Onetestresultwindowwillbedisplayed.Po

    int

    from

    theright

    topcornerofscre

    entoclosethewindow

    aftertheIpconfigresultwindow

    displayed.

    7.4.4.3ROUTEtest

    (1)Point

    ROUTETesttoenterintoopera

    tionwindow.

    (2)ChooseRou

    teParameterfromParametersetandpointOKto

    haveRoutetest.ThedefaultoneisPrint.

    (3)OneRoute

    resultwindowwillbedisplayed

    .Point

    from

    the

    righttop

    corner

    ofscreen

    to

    closethewindow

    aftertheRouteresult

    windowdisplayed

    .

    7.4.4.4TRACERTtest

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    21/31

    Ne

    tSparrowADSLZ60Tester

    41

    (1)Poin

    t

    TRACERTTesttoente

    rintooperationwindow.

    (2)Typead

    dressorwebaddressinDestin

    ationbar,chooseparameter

    fromTrace

    rtbar,pointOKtohaveTracertTest.

    (3)OneTracertresultwindowwillbedispla

    yed.Point

    fromtheright

    topcornerofscreentoclosethewindowaftertheTracertresultwindow

    displayed.

    7.4.5FixativeIPtest

    ToscanPC

    whichisinthesamenetworkpartwithtesterinsameLAN.

    TheIPaddressandnameofPConlinewillbedisplayed.

    (1)Point

    FixativeIPtoenterintooperationinterface.

    NetSparrowADSLZ60Tester

    42

    (2)LinkEthernetnetworklinewell,theEthernetindicatorlightwillbe

    bright.

    (3)PointOKtosearchPCwhichisinthesamenetworkpartandLAN.

    TheIPaddressandPC

    namewillbedisplayedonceonePC

    is

    searched.

    7.4.6Webpageb

    rowse

    Logonandbrowsew

    ebpage.

    (1)Point

    WebpageBrowsetoopenwebpage

    browser.

    (2)PointAddressb

    ar,theInputPanelwillbedisplayed.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    22/31

    Ne

    tSparrowADSLZ60Tester

    43

    (3)TypewebsiteaddressandpointEnteru

    singinputpaneltologonthe

    website.

    7.4.7FTP

    client

    ThetestercanprovidetheFTPclienttestfunction.

    (1)Point

    FTP

    ClienticontoopenthefollowingFTPclient

    window.

    (2)FilltheIPaddressofthewebsitewillbetestedintotheaddress

    barand

    alsotheusernameandpasswo

    rdthenpointtheconnectkey

    toenter.

    (3)PointtheParameterkeytoselectth

    eFTPmodeandport.

    (4)The

    leftblanketisthelistingoftheL

    ocalcatalogwhiletheright

    oneisthelistingoftheremotecatalog.

    Andtheconnectionstatewill

    bedisp

    layedatthedownleftcorner.

    (5)Point

    toentertheFTPco

    nnectionparametersetting.

    NetSparrowADSLZ60Tester

    44

    Theusercansetthe

    portandconnectionmode.

    7.4.8Webpages

    peedtest

    Thewebpagespeed

    testisforvalidatingthenetworkflux.

    (1)Point

    WebSpeedtesticontoopenthesp

    eedtestwindow.

    (2)Inputthewebsite

    IPaddressintotheaddressbar.Thenpressthetest

    keytostartthewebsitespeedtest.Theresultswillbedisplayedinform

    ofpictureortextacc

    ordingtheoption.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    23/31

    Ne

    tSparrowADSLZ60Tester

    45

    Re

    sultinpicture

    Resultintext

    Attentions

    :

    (1

    )InLANtesttheusershouldse

    tthegatewayandDNSwhile

    in

    xDSLtestcancelingthega

    tewayandDNS

    settingis

    necessaryandconnectedthrough

    PPPoE.

    (2

    )Pleasedonoticethatfilltherightaddressintotheaddress

    bar.Itcannotgetgoodeffectwhiletestingthewebsitewhichis

    usedtomakeaddressjumpattheserver.

    7.5DMM

    test

    AC/DCVoltage,

    Loop

    Resistance,C

    apacitance

    and

    Insulation

    Resistance

    canbetestedbybuilt-inM.Thelinemanwillbeinformed

    whetherthereisdangerousvoltageinthelineor48Vvoltageoftellineor

    not.

    (1)Point

    DMMTesttoenterintooperationwindow.

    NetSparrowADSLZ60Tester

    46

    (2)Connectthetest

    cordandthelinewhichwillbetested,pointdifferent

    icontohaverelevan

    ttestoperation.

    DCVoltageTest:

    Totestwhetherthe

    reissignalinthetestlineor

    not.Itonlycanbe

    operatedforDCvo

    ltagetest.Thetestrangeis262~262V.Whenit

    exceedstestrange.

    ThetesterwarnsasOvermax

    .

    ACVoltageTest:

    Totestwhetherthe

    reishighACvoltageinthelin

    eornotinorderto

    avoiddangersforlineman.WhenthereishighACvoltage,pleasetake

    offtestclampcarefu

    lly.

    ItisonlyforACvo

    ltagetest.Thetestrangeis-262262V.Whenit

    exceedstherange,thetesterwarnsasOvermax.

    LoopResistanceTest:

    Tocalculatelinelength.Ifthelinelengthisknown,toadjustwhetherthe

    lineconnectionisrig

    htornot.

    Calculatelinelength

    usingloopresistancevaluetested:

    L

    =RL/ROKm---------------------------

    Inexpressions:

    R

    L

    isloopresistancevalue(Unit:),RO

    isloop

    resistancevalueper

    kiloUnit:.

    For0.32mmdiameterofcopperline,RO=435.2;for0.4mmdiameterof

    copperline,RO=278

    .5;for0.5mmdiameterofcopp

    erline,RO=178.3.

    IfitdisplaysOverm

    ax,itmeansthetestclampisn

    otwelllinked,orline

    isnotlooplinked,o

    rtheloopresistanceexceedsr

    ange.Pleasecheck

    thetestclamporlinkthelinewellandhavetestagain.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    24/31

    Ne

    tSparrowADSLZ60Tester

    47

    Ifthereisvoltage(2V)intheline,itdisplaysACinline.Itmeans

    thereisvoltageintheline,theloopresistancecannotbetested.Please

    checkthelineandhavetestwhenthereisnovoltage.

    Capacitanc

    eTest:

    Thelinelengthcanbecalculatedwithcap

    acitancetestedifthereisno

    bridgeconnectioninthelineanditisnotso

    ggy.

    L=Cab/CO(Km)----------------------------------

    Intheexpression

    ,C

    ab

    iscapacitancevalue(Unit:nF),CO

    is

    capacitancevalueperkil(Unit:nF).

    IfitdisplaysOvermaxduringthetest

    process,itmeanstheline

    capacitanceexceedsrangeorthereisfaultintheline.Pleasecheckthe

    lineandhavetestagain.

    Ifthereisvoltage(2V)intheline,itdispla

    ysACinline.Itmeansthere

    isvoltage

    intheline,andthecapacitanc

    ecannotbetested.Please

    checkthelineandhavetestwhenthereisnovoltage.

    InsulationT

    est:

    Ifthereis

    smallinsulationresistanceva

    lue,itmeansthereisbad

    insulationintheline.TheADSLtransm

    issionperformancewillbe

    influenced.

    Themaintenanceisrequired.ADSLlineinsulationresistance

    valueshouldbemorethan10M.

    Ifthereisvoltage(2V)intheline,itdisplaysACinline.Itmeans

    thereisvoltageintheline,theinsulationca

    nnotbetested.Pleasecheck

    thelinean

    dhavetestwhenthereisnovoltage.Ifthelineinsulation

    resistanceexceedstherange,itdisplays50.0M,itmeanstheline

    insulationisgood.

    (3)PointCanceltocloseDMMtestwindo

    w.Thereisnotemessageof

    testresultstorage.PressOKtosaverecordandpressCanceltoclose

    it.

    NetSparrowADSLZ60Tester

    48

    Thedefaultfilenameislinexxxx-xxx.dmminwhichx

    isnumber.User

    canmodifyitastelephonenumber.

    Notice

    1.Itisgoodfor

    managementthattheline

    numberofDMM

    recordfilenameisthesameasphysicallayertestrecordline

    number.

    2.Youalsocannameitasyourownrules,whichwillmakeyour

    managementeasier.

    7.6Modem

    em

    ulation

    EmulateuserModemtotestwhetherthereisfaultin

    userModemornot.

    1Point

    M

    ODEMEmulationtoenterintooperationwindow.

    2Thetesterwille

    mulateuserModemtorealizeP

    PPoEDUN(Dial-Up

    Network).IftheVPI/VCIvalueneedstobemodified,pleasemodifyit

    fromModemParameterwindow.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    25/31

    Ne

    tSparrowADSLZ60Tester

    49

    3IfitneedstoexitModemEmulationsta

    te,pleasepointExitMODEM

    Emulation

    Status!toexitit.

    NOTES

    BecauseofgreatpowerlosswhenthetesterisinMODEMstate.We

    limittheMO

    DEMEmulationstatein15minutes.Ifitexceeds15minutes,

    theMODEMwillbeswitchedoffbytestera

    utomatically.

    7.7File

    management

    Tomanage

    andcheckfilessaveintester,includingrecordbrowse,save

    datainmemorykeyandfiletransferfunctio

    ns

    (1)Point

    FileManagementtoenter

    intooperationwindow.

    (2)Pointdifferenticontohaverelativetestoperation.

    7.7.1Rec

    ordbrowse

    Browsetes

    trecord,includinginformation

    ofDMMtest,physicallayer

    parameter,

    andchannelbitpic.

    (1)

    Point

    RecordBrowsetoenterintooperationwindow.

    NetSparrowADSLZ60Tester

    50

    ThefilewhichpostfixisdmmistheDMMtestre

    cord;thefilewhich

    postfixisphyisthe

    physicallayertestrecord.

    Choosethefileswh

    ichwillbecheckedfromselectfiledialogboxand

    choosetheneeded

    recordingfilefromthelist.The

    nconfirmandopen

    therelevantfileand

    therecordwillbedisplayed,

    DMMTestRecordw

    indow:

    PhysicalLayerPara

    meterTestRecordwindow:

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    26/31

    Ne

    tSparrowADSLZ60Tester

    51

    ADSL2+m

    oduletestrecord1

    AD

    SL2+moduletestrecord2

    ADSLmoduletestrecord

    PointCha

    nnelBitPic,thechannelbit

    picwillbedisplayed.Point

    Cancelbuttonandclosethewindow.

    7.7.2Mem

    orykeysave

    Transferfilessavedintesterormemorykeytoeachother.Makesureto

    insertmem

    orykeyintotester,andthemem

    orykeyisnotinwrite-protect

    state.

    1Point

    MemorykeySavetoente

    rintooperationwindow.

    NetSparrowADSLZ60Tester

    52

    (2)Thefilesavedin

    testerwillbedisplayedintheLocalfilebar;thefile

    savedinmemoryke

    ywillbedisplayedinRemotefilebar.

    (3)Choosefilefrom

    Localfilebar,thenpoint

    totransferfile

    intomemorykey;

    (4)choosefilefrom

    Remotefilebar,thenpoint

    tocopyfile

    intotester.

    (5)PointCanceltoclosethewindow.

    7.7.3Filetransfe

    r

    CopytestrecordfromtestertoSharedirectoryinoth

    erPCinLAN.Make

    suretheIPaddress

    oftesterandPCareinthesam

    enetworkpart,and

    thereisonesharedirectory.

    (1)Linknetworkline

    intoEthernetportwell,theEthernetindicatorlight

    willbebright.

    (2)Point

    File

    Transfertoenterintooperation

    window.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    27/31

    Ne

    tSparrowADSLZ60Tester

    53

    (3)Typead

    dressintoInputdestinationad

    dressbar,choosefilewillbe

    transferred

    fromSelectfilebar,pointFileTransfer,thefilechosenwill

    betransferredtothedirectory.

    Notice

    1.Pleasetypeinrightformatwhe

    nthedestinationaddressis

    in

    putted.

    2.Ifitisthefirsttimetovisitdestinationaddress,theuser

    nameandpasswordwindowwillbedisplayed.Ifyouhaveno

    usernameandpassword,justpointOK.

    7.7.4File

    management

    Managefilessavedinthetester,includingfiledeletionandfile

    transferring

    tomemorykey.

    (1)Pointthe

    FileManagementtoe

    nterthewindow:

    NetSparrowADSLZ60Tester

    54

    (2)Press

    toreturntotherootcatalog.

    (3)Press

    toreturnthenexthigherlevel.

    (4)Press

    tocopythefiletothememorykey.

    (5)Press

    todeletefile.

    7.8Help

    Providinginformatio

    nonsystemupgrading,operation,functionsetting,

    recalibrateandabou

    t.

    (1)Point

    HE

    LPtoenterintooperationwindo

    w.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    28/31

    Ne

    tSparrowADSLZ60Tester

    55

    (2)Pointdifferenticontohaverelevanttest

    operation.

    7.8.1Sys

    tem

    upgrade

    Therearetwowaystoupgradethesoftware.

    1.Upgrade

    softwarethroughLAN.

    2.Upgrade

    softwarethroughmemorykey.

    (1)Point

    System

    Upgrade

    toenterintoSystem

    Upgrade

    window,to

    choosetheupgrademode.

    (2)Userchoosessoftwareupgradem

    ethodfromLANandMemory

    keyme

    thods.

    LANmode

    (1)MakesuretheIPaddressoftesterandPCisinthe

    samenetworkpart.

    NetSparrowADSLZ60Tester

    56

    (2)Copytheupgradefiletoonesharefile.

    (3)InputrouteofupgradefilefromL

    ANroutebar,point

    OK.

    Memorykeymode

    (1)Copytheupgradefiletothememorykey.

    (2)InsertmemorykeyintotesterthroughUSBport.

    Copytheupgradefileintotheroot

    directoryofmemory

    key

    ,thenclickOKtocompletetheupgradeofthe

    sys

    tem.

    7.8.2Usenotes

    Introducedifferentkindsoffunctionandoperationway.

    1Point

    U

    seNotestoenterintooperationwindow.

    2Pointdifferent

    titletocheckintroduction.

    7.8.3Functionset

    ToperformtheManualclose/Automaticcloseswitc

    hset.Theusercan

    open/closetimingsw

    itchingoffbythisfunctionset.

    (1)Point

    functionseticontoenterthefunctionsetwindow.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    29/31

    Ne

    tSparrowADSLZ60Tester

    57

    (2)Ifyouch

    oosetheManualcloseoption

    theinstrumentwillbeclosed

    byyourself.Ifyoudonotclosetheinstrume

    ntitwillkeeponopen.

    (3)Oncese

    lectAutomaticcloseoptionthetesterwillautoswitchoff

    after10minutesidletosavepoweror15m

    inutesmodememulation.We

    regardAutomaticcloseasourdefaultoptioninordertosavepower.

    (4)Therevisingoftheswitchingoffiseffectiveincurrentoperation.If

    youclosethetestersettingwillbethedefaultautomaticclose.

    (5)Pleasedoremembertopressthesetke

    ytosaveyouroption.

    7.8.4Rec

    alibrate

    Thispartprovidestheaccuracyrecalibratingofscreenresponsetothe

    touchingstick.

    (1)Point

    recalibrateicontoenterthe

    recalibratewindow.

    NetSparrowADSLZ60Tester

    58

    (2)Point

    toco

    nfirmthecenterofthescreen.Thenthe

    will

    movetothefourco

    rnersofthescreenautomatica

    lly.Pleasepointthe

    whenitreachd

    ifferentcornerstohelptheinstrumenttoperformthe

    recalibratingofthe

    screensdifferentpart.After

    thefourcornersis

    confirmedpleasepo

    intenterkeytoconfirmthereca

    libratesetting.

    7.8.5About

    Softwarevisionand

    manufacturerinformation.

    PointAbouttochec

    krelevantinformation.

    7.9Charge

    Thetesterbatteryisinner7.4V2800mAhLi-batt

    ery,thebatterysign

    isempty,andthetesterwillpromptlowbattery

    topoweroff.About

    oneminutelater,

    thetesterwillbeautooff.Tomakesureyourusing,

    pleasechargeitimmediately.

    DuetotheLi-batterynothavingthememoryfunction,youcancharge

    itatanytime.We

    suggestyouchargeitwhenthebatterysignisone

    panetoavoidlow

    batteryaffectingyourjob.

    Chargingmethod:

    (1)Switchofftester,

    insertchargerinputplugintoAC

    220Vpowersupply,

    theindicatorlightwillbegreencolor.

    (2)Insertchargerou

    tputplugintotesterCHARGER

    port,theindicator

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    30/31

    Ne

    tSparrowADSLZ60Tester

    59

    lightwillbe

    redcolor,itmeansthetesteris

    beingcharged.

    (3)Aftertheindicatorlightbecomesgreenc

    olor,thetesterhasbeenfully

    charged.Pleasetakeoffthecharger.

    7.10BatteryReplacement

    Thebattery

    is7.4V2700mAhLibatteryand

    itsmeasureisWLH

    46mm9

    9mm14mm.Andthereisa2mmbumpertohelpprevent

    collisionbe

    tweenshellandbattery.We(

    manufacturer)couldprovide

    newpaying

    batterytoreplacetheoldtoth

    ecustomers.ItisalsoOKto

    taketheotherfactorysbatterywhichcouldmeetrequirements.Butwe

    suggesttakethemanufacturersbattery.

    Pleaseasktheprofessional

    stafftoreplacethebatterybyfollowingstep

    s.

    Step1:Ple

    asereleasethe4screwsby+

    typescrewdriverontheback

    shellandpullthebackshellbackwardvertically.

    Step2:Pleasereleasethe2screwsonba

    ckshellandpulltheback

    shellbackwardvertically.

    NetSparrowADSLZ60Tester

    60

    Step3:Unboltthepinbetweenbatteryandprintedboard.Then

    replacetheoldbatteryw

    iththenewone.An

    dinsertthebattery

    p

    inintotheX6

    seatoftheprintedboard.Pleasedonoticethatkeep

    theanode&catho

    deintherightpositions.

    Step4:Coverthebodywithbackshellandscrewonthetwoscrews.

  • 8/7/2019 Net Sparrow ADSL Z60 Tester

    31/31

    Ne

    tSparrowADSLZ60Tester

    61

    5:pu

    tthebackshellonthebody

    andscrewonthe4screws.

    seno

    ticethataligntheconnectorson

    backshellandbody.And

    astthingistoscrewonthe4screws.

    NetSparrowADSLZ60Tester

    62

    8.AnynaSuofofats

    Phenomenon

    Reason

    Solution

    Unableswitchontester

    Lowbattery

    Chargetester

    UnderthexDSLteststate,lin

    k

    NetSparrowADSLZ60Tester

    totheADSLline,theinner

    Modemcannotbein

    activationforlongtime

    1.Badlinkfortestline.

    2.Ifnosignalintheline,

    pleasetestwhetherthereis

    48VvoltagebyDMMtest

    function.

    1.Pleasehavetestafter

    confirmthewellconnection.

    2.Ifthereisnovoltage,it

    meansthereisnoservicein

    theline.

    Failedmodeminitialization

    1.Usersetthenetworkcard

    propertiesasDHCPmode.

    2.Userforbidstheusingof

    networkcard.

    1.Modifythenetworkcard

    propertiesandsetafixedIP

    address.

    2.Makenetworkpropertiesin

    normalstatus.

    AfterenterintoxDSLtest,th

    e

    undervoltagewarningwillb

    e

    displayinaveryshorttime.

    ThepoweroftheModem

    is

    bigandtheelectricitywillbe

    consumedfastbythexDSL

    testinthelowpower.

    Confirmthefullchargewhen

    youhavethexDSLtest.

    Memory

    key

    cannotb

    e

    identified

    Notallthememorykeyscan

    beidentifiedbytester.

    Pleasetryagain,ortochange

    anotherbrandofmemorykey.

    PPPoEDialconnectionfialed

    .

    To

    confirm

    the

    rightuser

    nameandpassword,andthe

    PPPoEPropertiessetting.

    ModifythePPPoEproperty

    accordingastheconnection

    requestofthelineandinput

    therightcodewhendialing.

    Webpagebrowsefailed

    Confirm

    successfulPPPoE

    dial

    Firstdialthe

    PPPoE

    No.

    Thenchangeawebaddress

    toconfirmthemistakeisnot

    becausetheserver.

    Ethernetindicatorlightisdark

    when

    the

    Ethernetcord

    is

    linkedintotester

    Networkcordisdividedinto

    crossanddirectnetworkcord.

    PleasetryanotherEthernet

    port.