network appliance.braindumps.ns0-506.v2015-10 … created a 5 tb vmware volume...
TRANSCRIPT
![Page 1: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/1.jpg)
NS0-506
Number: NS0-506Passing Score: 800Time Limit: 120 minFile Version: 4.0
http://www.gratisexam.com/
NS0-506
NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP
Version 4.0
![Page 2: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/2.jpg)
Exam A
QUESTION 1On a FAS8040, which port is used for FCoE connections?
A. e0MB. e0PC. 0aD. e0h
Correct Answer: DSection: (none)Explanation
Explanation/Reference:
QUESTION 2Click the Exhibit button.
Referring to the diagram shown in the exhibit, what will happen if PDU-B fails?
Exhibit:
![Page 3: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/3.jpg)
![Page 4: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/4.jpg)
A. Both Node A and Node B will remain online and all disk shelves will remain online.B. Both Node A and Node B will remain online, but all disk shelves will immediately lose power and
become inaccessible.C. Both Node A and Node B will immediately lose power and become inaccessible.D. Node A will immediately lose power and become inaccessible. Node B will remain online.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 3A customer has a clustered Data ONTAP solution and needs to connect several Windows 2012 serversusing iSCSI for LUN access.
Before the LUN can be seen, what must be configured on the host?
A. the LUN partitioningB. the Host Utilities KitC. the iSCSI software initiatorD. the HBA queue depth
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 4Which three environmental or physical requirements need to be met when designing a SAN solution?(Choose three.)
http://www.gratisexam.com/
A. rack spaceB. coolingC. clustered Data ONTAP versionD. IOPSE. power
Correct Answer: ACDSection: (none)Explanation
Explanation/Reference:
QUESTION 5You have a large, heterogeneous SAN environment. You are asked to gather information for all hosts,HBAs, switches, and storage. You are also told that you must collect this information over network protocolswithout agents.
![Page 5: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/5.jpg)
Which two NetApp tools allow you to perform this task? (Choose two.)
A. OnCommand InsightB. OnCommand ReportC. OnCommand Unified ManagerD. nSANity
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 6Which information-gathering command should you use to gather logs for troubleshooting switch informationfor your Brocade switches?
A. cfgshow
B. fabricshow
C. configshow
D. supportsave
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 7You are asked to migrate a SAN LIF to a node that was recently added to your cluster. The following CLIcommand was provided to you to complete the migration:
network interface modify -vserver svm1 -lif lif1 home -node cl01-04 -homeport6a
Which step is missing?
A. All hosts connecting to the controller through lif1 must be shut down.B. The LIF must first be added to a portset.C. Your zoning must be updated on the upstream switch.D. The LIF must be put in a status-admin down state.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 8You are verifying multipathing from the host to the storage controller.
Which three components should you verify? (Choose three.)
A. Verify that all switch ports connected to the hosts and storage devices are online using the vendor'sGUI.
B. Verify that both FC HBA ports in the host are online using the HBA vendor's GUI.
![Page 6: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/6.jpg)
C. Verify that the FC HBAs WWNN's are in the igroup in the SVM.D. Verify that the SVM's LIFs being used for multipathing are attached to the correct same physical FC
port.E. Verify that the storage controller FC target ports status are online with the switch port showing the FC
switch to which they are connected.
Correct Answer: ADESection: (none)Explanation
Explanation/Reference:
QUESTION 9Click the Exhibit button.
Referring to the exhibit, which entry is appropriate to add to a zone on the FC switch?
Exhibit:
A. 20:05:00:a0:98:29:18:76B. 20:10:00:a0:98:29:18:76C. 20:14:00:a0:98:29:18:76D. 50:10:00:a0:98:29:18:76
![Page 7: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/7.jpg)
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 10Exhibit
cl01::>igroup show -vserver
svm1
VserverIgroup Protocol OS
Type Initiators
--------- ------------- ------
-- --------- -----------------
--------------------
svm1 esx_cluster mixed vmware
20:00:00:25:b5:11:a0:01,
20:00:00:25:b5:11:b0:01,
iqn.1998-01.com.vmware:esx02
cl01::>
A customer is provisioning storage for two ESXi hosts using FCoE with CNA adapters. The customermapped the LUN to the igroup shown in the exhibit. After scanning for new devices, the LUN is only seenby one of the ESXi hosts.
What caused the problem?
A. One of the hosts is added in the igroip via iSCSI IQN.B. The igroup protocol needs to be configured as FCP.C. The switch zoning configuration does not include the correct initiators.D. The LIFs are not on their home ports.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 11An administrator wants to provide isolation among physical devices connected to the same FCP fabric.Which Cisco switch feature accomplishes this task?
A. VSANB. FSIPC. LUN maskingD. logical domains
Correct Answer: ASection: (none)
![Page 8: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/8.jpg)
Explanation
Explanation/Reference:Explanation: VSANs provide the following capabilities:
· Isolate devices physically connected to the same fabric.
Reference:http://www.cisco.com/en/US/products/ps5989/prod_troubleshooting_guide_chapter09186a008067a306.html
QUESTION 12You are creating a logical diagram for an FCP SAN solution.
You need to show connectivity between which three sets of components? (Choose three.)
A. management port and ACP cablingB. inter-cluster network ports and hostsC. hosts and FCP switchesD. hosts and FCoE switchesE. FCP switches and storage controller
Correct Answer: BDESection: (none)Explanation
Explanation/Reference:
QUESTION 13When designing a new SAN solution, which three components should be verified with the IMT? (Choosethree.)
A. the connection protocolB. the patch panel make and modelC. host OS type and versionD. the type of Ethernet switchE. the clustered Data ONTAP version
Correct Answer: CDESection: (none)Explanation
Explanation/Reference:
QUESTION 14Which two port personality combinations are valid for the onboard UTA2 ports on a FAS8040 controller?
A. e0e/0e - fce0f/0f - fce0g/0g - cnae0h/0h -cna
B. e0e/0e - fce0f/0f - cnae0g/0g - fce0h/0h -cna
C. e0e/0e - fce0f/0f - fce0g/0g - fce0h/0h -cna
![Page 9: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/9.jpg)
D. e0e/0e - cnae0f/0f -cnae0g/0g - fce0h/0h - fc
Correct Answer: CSection: (none)Explanation
Explanation/Reference:
QUESTION 15Click the Exhibit button.
An administrator is attempting to map an iSCSI LUN to a Windows 2012 host, but the windows host fails todiscover the iSCSI targets.
Referring to the exhibit, what is the connectivity problem?
Exhibit:
![Page 10: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/10.jpg)
A. The iSCSI service is running on svm1, but iSCSI is not licensed on the nodes.B. The iSCSI LIFs are not currently on their home port.C. The iSCSI LIFs are currently disabled.D. The LIFs do not have a failover group defined.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 16Exhibit
![Page 11: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/11.jpg)
cl01::>ucadmin show
Current Current Pending
Pending Admin
Node Adapter Mode Type Mode
------------- ------- -------
--------- -------- --------- -----------
cl01-01 0c fc target - -
online
cl01-01 0d fc target - -
online
cl01-01 3a cna target - -
online
cl01-01 3b cna target - -
online
cl01-01 4a cna target - -
online
cl01-01 4b cna target - -
online
cl02-01 0c fc target - -
online
cl02-01 0d fc target - -
online
cl01-02 3a cna target - -
online
cl01-02 3b cna target - -
online
cl01-02 4a cna target - -
online
cl01-02 4b cna target - -
online
12 entries were displayed.
cl01::>
Referring to the exhibit, which cables are valid for connecting port 0d on node cl01-02 when the switch is 10meters away?
![Page 12: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/12.jpg)
A. Twinax copper SFP+ active cablesB. Twinax copper SFP+ passive cablesC. LC/LC optical OM3 cablesD. RJ45 Cat6 Ethernet cables
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 17A company has a 4-node Data ONTAP cluster called cl01. The administrator attempts to create a volumeon svm1 and can only select aggregates that are owned by node cl01-01 or cl01-02.
What is causing the problem?
A. The SVM peering relationship has not been configured with the cl01-03 and cl01-04 HA pair.B. The storage virtual machine is not configured to use nodes cl01-03 or cl01-04.C. No LIFs have been created on nodes cl01-03 or cl01-04.D. Volume creation delegation is not configured to allow use of cl01-03 or cl01-04 owned aggregates.
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 18You created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. The storage efficiencysavings of the vmdks are one over 50%, but the application team wants to minimize the possibility of anout-of-space condition. You enable autogrow, autoshrink, and snapshot autodelete with the followingcommands:
volume modify -vserver vm1 -volume vol_esx_nfs1 -space-mgt-try-firstvolume_grow
snapshotautodelete modify -vserver vm1 -volume vol_esx_nfs1 -enabled true -delete-
orderoldest_first -target-free-space 10% -trigger volume
volautosize -vserver vm1 -volume vol_esx_nfs1 -mode grow_shrink -maximum-size10 TB
minimum-size 5 TB -grow-threshold-percent 80 -shrink-threshold-percent 60
What will these commands do?
A. Delete the oldest Snapshot copies before growing the volume.B. Increase the Snapshot copy reserve before growing the volume.C. Shrink the volume before deleting the Snapshot copies.D. Grow the volume before deleting the Snapshot copies.
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
![Page 13: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/13.jpg)
QUESTION 19Which resource would you use to search for information about the configurations for NetApp products thatwork with third-party solutions?
A. Config AdvisorB. Host Utility KitC. Interoperability Matrix ToolD. Clustered Data ONTAP 8.3 SAN Administration Guide
Correct Answer: CSection: (none)Explanation
Explanation/Reference:Reference: http://hwu-stage.netapp.com/Resources/FundedTools.htm
QUESTION 20What is a NetApp-recommended zoning best practice?
A. Switch port zoning should always be employed.B. WWNN zoning is required.C. Single-initiator zoning is recommended.D. Zones can overlap.
Correct Answer: CSection: (none)Explanation
Explanation/Reference:
QUESTION 21A customer has recently deployed a clustered Data ONTAP 8.3 system and is trying to mount LUNs to aWindows 2012 Server using the iSCSI protocol. They have enabled jumbo frames on their nodes as well astheir Windows 2012 Server. Whenever they attempt to scan for a new LUNs, Disk Management times outand does not present any new storage.
What is causing the problem?
A. Windows 2012 does not support jumbo frames with the iSCSI protocol.B. Clustered Data ONTAP 8.3 does not support the iSCSI protocol.C. They have jumbo frames enabled on the host and storage, but not the Ethernet switches.D. Clustered Data ONTAP 8.3 does not support jumbo frames with the iSCSI protocol.
Correct Answer: CSection: (none)Explanation
Explanation/Reference:
QUESTION 22Exhibit
cl01-01::>vol show -vserver
svm1 volume v_iscsi_exch01
Vserver Name: svm1
![Page 14: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/14.jpg)
Volume Name: v_iscsi_exch01
Aggregate Name: a1_cl01_sas
Volume Size: 5 GB
Volume State: online
Volume Type: RW
Volume Style: flex
Available Size: 4.75GB
Filesystem Size: 5GB
Total User-Visible Size:
4.75 GB
Used Size: 144 KB
Used Percentage: 5%
Volume Nearly Full Treshold
Percent: 95%
Volume Full Treshold
Percent: 98%
Maximum Autosize (for
flexvolvs only): 6GB
(DEPRECATED) -Autosize
Increment (for flexvolvs
only): 256MB
Minimum Autosize: 5GBAutosize Grow Threshold
Percentage: 85%
Autosize Shrink Threshold
Percentage: 50%
Autosize Mode: off
Autosize Enabled (for
flexvolvs only): false
Space Guarantee Style: volume
Space Guarantee in Effect:
true
Snapshot Directory Access
Enabled: true
![Page 15: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/15.jpg)
Space Reserved for Snapshot
Copies: 5%
Snapshot Reserve Used: 0%
Snapshot Policy: none
Node name: cl01-01
Reserved Space for
Overwrites: 0B
Fractional Reserve: 100%
Primary Space Management
Strategy: volume_grow
Total Physical Used Size:
144KB
Physical Used Percentage: 0%
A customer has a volume with the configuration shown in the exhibit.
What will happen if the volume vs_iscsi_exch01 reaches 85% used?
A. The volume will delete snapshots until 20% is free in the volume.B. The volume will automatically grow up to 6 GB.C. The volume will no longer be accessible from the host.D. The volume will continue working as expected.
Correct Answer: DSection: (none)Explanation
Explanation/Reference:
QUESTION 23You have a new FAS8080EX 2-node cluster. The FC switch ports connected to the onboard UTA2 ports willnot come online.
Which two node-based issues would case the problem? (Choose two.)
A. The UTA2 ports are set to target.B. The UTA2 ports have 10 GB SFP+ optics installed.C. The UTA2 ports have 16 GB SFP+ optics installed.D. The UTA2 ports are in cna mode.
Correct Answer: DSection: (none)Explanation
Explanation/Reference:
QUESTION 24A company has 50 ESXi hosts connected using FC to a single target port on a NetApp cluster. Ten hostsare configured with an HBA queue depth on 128. Forty hosts are configured with a HBA queue depth of 32.
![Page 16: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/16.jpg)
They are experiencing performance problems with their FC LUNs.
Which two actions will resolve the problem? (Choose two.)
A. Use VSC to set recommended values for the hosts.B. Reduce the HBA queue depth on the on the applicable HBAs.C. Add additional target ports to allow for greater initiator distribution.D. Increase the total queue depth on the NetApp cluster.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 25You are planning to move to a newer clustered Data ONTAP version.
Which two resources should you review prior to the move? (Choose two.)
A. Software Setup GuideB. IMTC. Upgrade AdvisorD. System Administration Guide for Cluster Administrators
Correct Answer: BCSection: (none)Explanation
Explanation/Reference:Reference: https://library.netapp.com/ecmdocs/ECMP1368868/html/GUID-9194A9CF- F7F8-48B5-82B0-D494D3D64105.html
QUESTION 26Which two flags would you use to enable NetApp thin provisioning on a LUN? (Choose two.)
A. -space-reserve enabled -space-allocation enabledB. -space-reserve enabled -space-allocation enabledC. -space-reserve disabled -space-allocation disabledD. -space-reserve disabled -space-allocation enabled
Correct Answer: ACSection: (none)Explanation
Explanation/Reference:
QUESTION 27A customer has a host experiencing performance problems with its FC LUNs. The customer has examinedthe nodes hosting the LUNs, and both the disk and CPU performance are below 50% utilization. Thecustomer examined the switch ports connected to the storage array, and they are also below 50%utilization.
Which three should the customer verify? (Choose three.)
A. that the HBA queue depth is set properlyB. that the host HBA has the correct port settingsC. that the host Ethernet interfaces are using jumbo frames
![Page 17: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/17.jpg)
D. that the host is running SnapDriveE. that the FC switch ports connected to the host have not exceeded the maximum capacity
Correct Answer: CDSection: (none)Explanation
Explanation/Reference:
QUESTION 28A customer is configuring their host for FC connectivity to a clustered Data ONTAP storage solution. Theyhave installed a 4 GB FC HBA into the host and connected it with optical cables to an 8 GB FC switch. Theyhave also connected the UTA2 ports from the FAS2552 with 16 GB SFP+ optics installed using opticalcables to the switch.
Which two actions will improve host FCP throughput? (Choose two.)
A. replacing the existing 8 GB FC switch with a new 16 GB FC switch.B. replacing the switch with a 10 GB Ethernet switchC. adding 16 GB FC HBA and appropriate opticsD. replacing the optical cables with copper TwinAx cables.
Correct Answer: BCSection: (none)Explanation
Explanation/Reference:
QUESTION 29What is installed on your Linux host when you install the Linux Unified Host Utilities 7.0?
A. drivers and firmwareB. software iSCSI initiatorC. SAN Toolkit data collection utilityD. nSANity
Correct Answer: CSection: (none)Explanation
Explanation/Reference:Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1654941
QUESTION 30You configure space-reserved LUNs on thick-provisioned volumes, and you want to guarantee overwrites.
How would you accomplish this task?
A. Set the fractional reserve to 0%.B. Enable space allocation.C. Set the fractional reserve to 100%.D. Disable the fractional reserve.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
![Page 18: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/18.jpg)
Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1636035 (page 18)
QUESTION 31Which objects reside inside an igroup?
A. host initiatorsB. LUNsC. qtreesD. volumes
Correct Answer: ASection: (none)Explanation
Explanation/Reference:Reference: https://library.netapp.com/ecmdocs/ECMP1368845/html/GUID-BBD6165F- 0D72-46A4-B669-3B6D14F2C7C0.html
QUESTION 32You are troubleshooting a node that had a core dump. The HA partner took over and you successfullyperformed a giveback. You need to get access to the core files.
Which two locations will give you access? (Choose two.)
A. /mroot/etc/crashB. https://<cluster-mgmt-LIF>/spi/C. https://<cluster-mgmt-LIF>D. /mroot/etc/log
Correct Answer: ASection: (none)Explanation
Explanation/Reference:Reference: https://library.netapp.com/ecmdocs/ECMP1155684/html/GUID-BDFE73DB- A1E1-4B1B-96D1-CF2A04DA0AF8.html
QUESTION 33On a Windows 2012 Server, the FC load balance policy is configured using which two utilities? (Choosetwo.)
A. NetApp OnCommand System ManagerB. Data ONTAP DSM for Windows MPIOC. Windows MPIOD. Unified Host Utilities
Correct Answer: BDSection: (none)Explanation
Explanation/Reference:Reference: https://library.netapp.com/ecmdocs/ECMP1656700/html/GUID-243B543E- 070F-46E9-9636-6CF8B91EEB82.html
QUESTION 34Exhibit
You currently have the following configuration on your cluster:
cl01::>igroup show -instance
![Page 19: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/19.jpg)
Vserver Name: svm1
Igroup Name: ig2
Protocol: mixed
OS Type: linux
Portset Binding Igroup: -
Igroup UUID: 3fb136c7-cfd6-11df-a9ab-123478563412 Initiators: -
What must you do to limit the LIFs that are used by an initiator to access a LUN?
A. Create a portset.B. Create an additional igroup.C. Change the protocol to iSCSI.D. Change the OS type to windows_gpt.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:Reference: https://library.netapp.com/ecmdocs/ECMP1368525/html/GUID-5CC27202- A43F-429F-AB13-C70E7CD58E09.html
QUESTION 35A new server has been installed in your environment, but it is unable to see its NetApp boot LUN. You havenarrowed the problem down to the zoning on your Cisco switch which has the following configuration:
zone name z_NetAppvsan 400
memberpwwn 20:00:00:25:b5:c0:ff:ee
memberpwwn 50:0a:09:84:8d:7c:51:d5
zoneset name zs_NetAppvsan 400
memberz_NetApp
zoneset activate name zs_NetAppvsan 400
What is the problem with your zoning configuration?
A. The member does not reference the VSAN.B. The zone and zoneset names do not match.C. The zoneset was improperly activated.D. The PWWN for your NetApp LIF is incorrect.
Correct Answer: DSection: (none)Explanation
Explanation/Reference:
QUESTION 36A Windows 2012 Server has a 1 GB thin-provisioned LUN in a 10 GB thin-provisioned volume. Aftercopying a 500 MB file to the LUN, you observe the LUN using 500 MB of space in the volume. After deletingthe 500 MB file, you observe the LUN is still using 500 MB of space in the volume.
![Page 20: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/20.jpg)
Which two steps are required to reclaim the space? (Choose two.)
A. Press Optimize in the Windows Defragment and Optimize Drives utility.B. Enable space-allocation on the LUN.
C. Run TRIM on the host.D. Empty the Recycle Bin on the host.
Correct Answer: CSection: (none)Explanation
Explanation/Reference:
QUESTION 37After mapping the LUN on the cluster, you are not able to see in on the Windows 2012 host.
cl01::>igroup show -instance
Vserver Name: svm1
Igroup Name: ig1-win
Protocol: iscsi
OS Type: Windows
Portset Binding Igroup: -
Igroup UUID: 358338ba-cfd6-
11df-a9ab-123478563412
Initiators: iqn.1991-
05.com.microsoft: host1 (not
logged in)
Referring to the exhibit, what is the problem?
A. An administrator is not logged into the host.B. The iSCSI target has not been added to the host.C. The OS type should be windows_2008.D. The OS type should be windows_gpt.
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 38You want to prevent an FCoE frame from being split into two Ethernet frames.
What is the minimum required frame size that will satisfy this requirement?
A. 9216B. 2240C. 1512D. 9000
![Page 21: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/21.jpg)
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 39A storage administrator has the configuration shown in the exhibit.
In which scenario would a volume move be successful?
cl01::>vserver show -vserver
svm1
Vserver: svm1
Vserver Type: data
Vserver UUID: 1630b8eb-c2a6-
11e4-a7dd-123478563865
Root Volume: svm1_root
Aggregate: Node1_aggr1,
Node2_aggr1
Name Service Switch: file,
nis
Allowed Protocols: fcp
Disallowed Protocols: nfs,
cifs, iscsi, ndmp
Is Vserver with Infinite
Volume: false
QoS Policy Group: -
cl01::>vserver show -vserver
svm2
Vserver Type: data
Vserver UUID: 1630b8eb-c2a6-
11e4-a7dd-123478563412
Root Volume: svm2_root
Aggregate: Node1_aggr1,
Node2_aggr1, Node1_aggr2
Name Service Switch: file,
nis
![Page 22: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/22.jpg)
Allowed Protocols: fcp
Disallowed Protocols: nfs,cifs, iscsi, ndmp
Is Vserver with Infinite
Volume: false
QoS Policy Group: -
cl01::>
A. from svm1 aggregate Node1_aggr1 to svm1 aggregate Node2_aggr1B. from svm1 aggregate Node1_aggr1 to svm2 aggregate Node1_aggr2C. from svm2 aggregate Node1_aggr1 to svm2 aggregate Node1_aggr2D. from svm1 aggregate Node1_aggr1 to svm1 aggregate Node1_aggr2
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 40Exhibit
cl01::>lun mapping show -
vserver svm1 -
path /vol/svm1_vol1/lun1 -
igroup svm1-ig1
Vserver Name: svm1
LUN path: /vol/svm1_vol1/lun1
Volume Name: svm1_vol1
Qtree Name: ""
LUN Name: lun1
Igroup Name: svm1-ig1
Igroup OS Type: windowsIgroup Protocol Type: iscsi
LUN ID: 3
Portset Binding Igroup: -
ALUA: true
Initiators: iqn.1991-
05.com.microsoft: host1
LUN Node: cl01-04
Reporting Nodes: cl01-01,
![Page 23: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/23.jpg)
cl01-02, cl01-03, cl01-04
You have a 2-node cluster. You have added an HA pair with all flash drives for a high- performancedatabase that is currently experiencing performance problems on SAS drives. The LUN shown in the exhibitis moved from cl01-01 to cl01-04 to address the problems.
What is the next step in this scenario?
A. Rescan the host to discover the new LUN location.B. Remove the old path entries from the host.C. Remove the previous owner and partner from the reporting nodes list.D. Unmap the LUN, then remap the LUN.
Correct Answer: DSection: (none)Explanation
Explanation/Reference:
QUESTION 41Exhibit
cl01::>iscsi portal show
Logical Status CurrCurr
Vserver Interface TPGT
Admin/Oper IP Address Node
Port Enabled---------- ---------- ---- --
-------- ---------------- ----
------- ---- -------
svm1 1-a 1035 up/up
192.168.1.66 cl01-01 e0a true
svm1 1-b 1051 up/up
192.168.1.67 cl01-01 e0b true
svm1 2-a 1046 up/down
192.168.1.68 cl01-02 e0a true
svm1 2-b 1052 up/up
192.168.1.69 cl01-02 e0b true
Referring to the exhibit, which action would you take to troubleshoot the iscsi-2-a interface?
A. Verify that the iSCSI protocol is licensed for svm1.B. Cycle the upstream switch port down and back up again.C. Verify network connectivity between the host and LIF.D. Verify that the iSCSI protocol is started on svm1.
Correct Answer: BSection: (none)Explanation
![Page 24: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/24.jpg)
Explanation/Reference:
QUESTION 42You want to verify that a host will be able to see the storage. A LUN is mapped to an igroup for the host,and both the host and storage are connected to FC switches.
Which command will provide the path status information from the switch?
A. configure
B. cfgshow
C. fcping
D. zoneshow
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 43You are asked to configure the Service Processor on a newly installed node, and must verify the followingcommand:
system-service processor network modify -node local -address-family IPv4 --enable true-ip-address 192.168.123.98 -netmask 255.255.255.0
Which statement about this command is true?
A. -node should reference the actual node name.
B. The gateway IP address is missing.C. The Link Local IP Address is missing.D. IPv6 is required for the SP.
Correct Answer: ASection: (none)Explanation
Explanation/Reference:
QUESTION 44Inside of an SVM, an iSCSI IP address is defined on which object?
A. qtreeB. LUNC. LIFD. node part
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 45Which protocol allows to access a controller's CLI interface?
![Page 25: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/25.jpg)
A. SSHB. NTPC. TFTPD. IMAP
Correct Answer: ASection: (none)Explanation
Explanation/Reference:Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1196798 (page 11)
QUESTION 46Microsoft ODX supports which scenario on clustered Data ONTAP 8.3?
A. moving a VHDX with both SMB 3.0 and SAN protocols as either source or destinationB. moving a VHDX from an SMB 3.0 source to an SMB 3.0 destination with no SAN supportC. moving a VHDX from a SAN LUN source to a SAN LUN destination with no SMB supportD. moving a VHDX with both SMB 2.1 and SAN protocols as either source or destination
Correct Answer: DSection: (none)Explanation
Explanation/Reference:
QUESTION 47You are zoning a fabric for a clustered Data ONTAP storage system. After cabling, you see the followingaddresses logged into the fabric:
20:04:00:a0:98:16:db:9c
50:0a:09:83:8d:b1:ce:c3
What should be included in the zone configuration?
A. 50:0a:09:83:8d:b1:ce:c3 and the initiator WWNNB. 50:0a:09:83:8d:b1:ce:c3 and the initiator WWPNC. 20:04:00:a0:98:16:db:9c and the initiator WWPND. 20:04:00:a0:98:16:db:9c and the initiator WWNN
Correct Answer: BSection: (none)Explanation
Explanation/Reference:
QUESTION 48A customer is experiencing slower than expected performance on a database connected to an iSCSI LUN.They are surprised that performance has decreased even though they have upgraded from a 1 GB to a 10GB switch.
What are three causes for this problem? (Choose three.)
A. Spanning Tree is incorrectly configured on the cluster nodes.B. There is a faulty cable or SFP in the data path.C. There is an MTU mismatch between the hosts, controllers, and switch.
![Page 26: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/26.jpg)
D. Flow control is incorrectly set on either the host or controllers.E. Routing is not set up between the iSCSI and cluster networks.
Correct Answer: ABCSection: (none)Explanation
Explanation/Reference:
QUESTION 49Click the Exhibit button.
A customer has deployed a new FAS8080EX running clustered Data ONTAP 8.3. Host A is runningmultipath software that has been properly configured. Also, Host A is currently accessing a LUN using theFC protocol stored on Node A. Switch A, shown in the exhibit, fails.
What will happen next?
Exhibit:
![Page 27: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/27.jpg)
A. Node A will panic causing a storage failover to Node B.B. Host A will lose all access to its LUN.C. Host A will continue to access its LUN using Switch B through Node B.D. Host A will continue to access its LUN using Switch B through Node A.
Correct Answer: BSection: (none)Explanation
![Page 28: Network Appliance.BrainDumps.NS0-506.v2015-10 … created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. ... A. Config Advisor ... flex Available Size: 4.75GB](https://reader031.vdocument.in/reader031/viewer/2022032613/5aa857fc7f8b9a95188b7068/html5/thumbnails/28.jpg)
Explanation/Reference:
http://www.gratisexam.com/