new tools for pv array commissioning and...
TRANSCRIPT
![Page 1: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/1.jpg)
New Tools for PV Array
Commissioning and Troubleshooting
Megger®
MIT430
Solmetric
PVA-600
Paul HerndayApplications [email protected] 707-217-3094
February 9, 2012
![Page 2: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/2.jpg)
Solmetric Solutions
www.solmetric.com
![Page 3: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/3.jpg)
Solar PV Installation Life Cycle
![Page 4: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/4.jpg)
Topics
• PV array performance verification
• Introduction to I-V curves
• The Solmetric PVA-600 PV Analyzer
• Demo of the PV Analyzer user interface
• Commissioning & troubleshooting PV array performance
• Meg testing with the Megger® MIT430
![Page 5: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/5.jpg)
Array Performance Test MethodsFor Startup/Commissioning/Checkups/Service Alarms
Inverter readout
String I-V curve measurements
String DC measurements
Basic Comprehensive
I
V
Verification methods are evolving in response to
increasing emphasis on energy production
![Page 6: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/6.jpg)
“I often tell students in my classes to learn to think like a PV array.
Thinking like a PV array requires understanding the I-V curve and how it
changes based on ambient conditions and array problems. An I-V curve
tracer is the best way to gain an understanding of these changes, since it provides a graphical representation of the array operating characteristics.”
“I-V curve tracing is the most informative measurement that can be performed
on a PV module or array.”
I-V Curve Tracing is a PV Best Practice
David KingDK Solar Works
Developer of the Sandia PV Array Model at Sandia National Labs
SolarPro, Aug/Sep 2011
Bill BrooksBrooks Engineering
SolarPro, Aug/Sep 2011
![Page 7: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/7.jpg)
� Fast – it’s a single electrical connection & a single measurement
� The most comprehensive PV measurement possible
� No need to bring the inverter on-line to fully test the array
� Close out projects earlier ($$$ flow earlier)
� Detailed baseline for comparison as arrays age & degrade
Benefits of I-V Curve Performance Testing
Commissioning New PV Systems
� Troubleshoot more efficiently
� Sort out module versus inverter issues
� Provide convincing data for module warranty claims
� Keep arrays producing maximum energy
Maintaining PV Systems (O&M, Asset Management)
![Page 8: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/8.jpg)
PV Analyzer Users
EPC organizations
System Integrators
Consulting Engineers
Training OrganizationsTechnical colleges
Module Manufacturers
Inverter Manufacturers
IBEW
Training Centers
O&M Companies
Electrical contractors
![Page 9: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/9.jpg)
Topics
• PV array performance verification
• Introduction to I-V curves
• The Solmetric PVA-600 PV Analyzer
• Demo of the PV Analyzer user interface
• Commissioning & troubleshooting PV array performance
• Meg testing with the Megger® MIT430
![Page 10: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/10.jpg)
Solar Cell
1
2
3
3
Cells are in series ���� a single cell can be a bottleneck.
A 12-module string may have
12 x 72 = 864 cells in series.
Charge generation
Charge separation
Charge collection
1
2
3
Photon
Top layer
Bottom layer
Fingers
Backside
![Page 11: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/11.jpg)
What is an I-V curve?And how is it measured?
AdjustableLoad
Load can be•Resistive•Capacitive•Electronic
MeasurecurrentMeasure
voltage
Current
Voltage
Built-in PV models mean
user can instantly check
performance against
expectations for the
existing irradiance and
temperature.
![Page 12: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/12.jpg)
I-V and P-V* CurvesExpect this shape for healthy cells, modules, strings, arrays
Current
Voltage
Isc
Voc
I-V curve
Vmp
Imp
Power
P-V curve
Pmax
*P-V curve is calculated from the measured I-V curve
![Page 13: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/13.jpg)
‘Stacking’ PV Modules into Arrays
This ‘building block’ analogy is useful in troubleshooting arrays
I
V
I-V
building
blocks
Series
Parallel
Total (net) I-V curve
I
V
I-V
building
blocks
Series
Parallel
Total (net) I-V curveCurrent
Voltage
![Page 14: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/14.jpg)
Max power point
I-V Curve Signatures of PV Problems
Any reduction of the knee of the curve
means reduced output power.
Current (A)
Voltage (V)
Isc
Voc
Shunt losses*
Series losses**
Mismatch losses (incl. shading)
Normal I-V curve
Reducedcurrent
Reducedvoltage
Conventional measurements do not reveal many of these effects.
![Page 15: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/15.jpg)
Topics
• PV array performance verification
• Introduction to I-V curves
• The Solmetric PVA-600 PV Analyzer
• Demo of the PV Analyzer user interface
• Commissioning & troubleshooting PV array performance
• Meg testing with the Megger® MIT430
![Page 16: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/16.jpg)
• Complete performance measurement up to 600V, 20A
• Comparison to built-in models
• Wireless interface to your PC
String measurement showing I-V and P-V curves,
and comparison of I-V curve with model (5 dots).
Solmetric PVA-600 PV Analyzer
![Page 17: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/17.jpg)
Courtesy of:Integrated Energy SystemsPittsburg Unified School DistrictSage RenewablesStellar Energy Solutions
Example Measurement Setup
![Page 18: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/18.jpg)
Example Measurement Setup
Courtesy of Chevron Energy Solutions © 2011
![Page 19: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/19.jpg)
PVA-600 Block Diagram(simplified)
Controller&
Wireless
I sense
V senseC
Control button withLED indicator
Battery charging connector
(1 of 3)
• Capacitive load method (3 capacitor values, auto-selected)
• Electrically isolated. Ground lead is not required
• Protection for over-voltage, -current, -temperature, & reverse polarity
PV TestLeads
NEMA 4X FG Enclosure
![Page 20: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/20.jpg)
Wireless Sensor KitIrradiance & temperature sensors
Irradiance
transmitter
Receiver (USB)
Temperature
transmitter
K-type
thermocouple
Omega Part #
5SRTC-GG-K-
30-72
.
![Page 21: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/21.jpg)
Comparing PVA measurement with
resistive load method
Resistive
load
Resistive
load
Switch
![Page 22: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/22.jpg)
Data points from the
resistive load method
Method:•Clear sky, solar noon.
•Quickly alternate the two methods.
•New resistance at each load point.
![Page 23: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/23.jpg)
PV Models in the PV AnalyzerPredict PV array performance for immediate comparison
• Sandia National Labs PV Array Model
– Most comprehensive (30+ parameters)
– ~500 PV modules
• 5-Parameter Model
– Developed at U. Wisconsin, used by CEC for NSHP program
– ~5000 PV modules
– Less reliable results for amorphous silicon technologies
• Simple Datasheet Model (predicts Pmax)
– User enters data sheet parameters (Isc, Voc, Pmax & temp co’s)
– Translates datasheet Pmax (STC) to actual irradiance & temperature
These 3 methods are available in the Solar Advisor Model (SAM) from NREL and are embedded in the Solmetric PV Analyzer.
![Page 24: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/24.jpg)
Topics
• PV array performance verification
• Introduction to I-V curves
• The Solmetric PVA-600 PV Analyzer
• Demo of the PV Analyzer user interface
• Commissioning & troubleshooting PV array performance
• Meg testing with the Megger® MIT430
![Page 25: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/25.jpg)
Topics
• PV array performance verification
• Introduction to I-V curves
• The Solmetric PVA-600 PV Analyzer
• Demo of the PV Analyzer user interface
• Commissioning & troubleshooting PV arrays
• Meg testing with the Megger® MIT430
![Page 26: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/26.jpg)
Example Measurement Setup
![Page 27: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/27.jpg)
I-V Measurement SetupExample: Measuring strings at a combiner box
![Page 28: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/28.jpg)
Mounting the Thermocouple
•Use metalized HVAC tape or Kapton tape for high temperature stability
•Press firmly to assure intimate contact between TC and backside
•Fold a tab so you can remove the tape
Suggested replacement TC:Beaded K-typeOmega Part No.5SRTC-GG-K-30-72
![Page 29: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/29.jpg)
Test ProcessExample: Measuring strings at a combiner box
Hardware setup (do once at each combiner box):
1. Move the sensors (if necessary)
2. Isolate the combiner box (open the DC disconnect)
3. De-energize the buss bars (lift the string fuses)
4. Clip test leads to the buss bars
1. Insert a string fuse
2. Press “Measure”
3. View and save results
4. Lift the fuse
Electrical measurement (repeat for each string):
10-15 seconds, typically
![Page 30: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/30.jpg)
Example Measurement Setup860kW 7-inverter system
Courtesy of Portland Habilitation Center and Dynalectric Oregon
• Open the DC disconnect
for the sub-array you
want to test.
![Page 31: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/31.jpg)
Example Measurement SetupCombiner boxes for one inverter
Courtesy of Portland Habilitation Center and Dynalectric Oregon
• Locate the
combiner box
![Page 32: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/32.jpg)
Example Measurement SetupCombiner box wiring
Courtesy of Portland Habilitation Center and Dynalectric Oregon
• With a clamp-meter,
verify that the load has
been disconnected.
• Then lift all of the
fuses.
![Page 33: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/33.jpg)
Example Measurement SetupInsert a single fuse to test the corresponding string
Courtesy of Portland Habilitation Center and Dynalectric Oregon
• Clip the PV Analyzer to
the buss bars.
• Push down one fuse at
a time and make I-V
curve measurements.
• View and save results.
![Page 34: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/34.jpg)
How Data Is Stored
Saving data in the Array Tree
allows the I-V Data Analysis Tool
to:
Created
when you
install the
PVA PC
software
• Automatically analyze your data
• Identify non-conforming strings
• Provide convincing charts for your
commissioning report
![Page 35: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/35.jpg)
Demo of I-V Data Analysis Tool
![Page 36: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/36.jpg)
Displays Generated by theI-V Data Analysis Tool*
1950
2000
2050
2100
7
6
5
4
3
2
1
0
Fre
qu
en
cy
Pmax (Watts)
7
6
5
4
3
2
1
0
Cu
rren
t (A
mp
s)
0 100 200 300 400 500
Voltage (Volts)
7
6
5
4
3
2
1
0
Cu
rren
t (A
mp
s)
0 100 200 300 400 500
Voltage (Volts)
*Optional, MS Excel-based tool, $95
![Page 37: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/37.jpg)
• Clear sky (for high, stable irradiance)
– Height of I-V curve varies directly with irradiance
– I-V curve changes shape at low irradiance
– At low light, comparison to models or STC is much less accurate
• 4 hour window centered on solar noon*
– Avoids the low-light issues mentioned above
– Avoids any major angle of incidence and spectral effects
• Low/No wind (for more consistent module temperature)
– Width of I-V curve varies inversely with temperature
– Temperature is not uniform across an array under any conditions
Recommended Sky ConditionsFor Array Performance Testing
http://www.esrl.noaa.gov/gmd/grad/solcalc/
*Solar Noon Calculator:
Inconsistent conditions (clouds, wind) cause more variation in PV measurement results,
making strings look less consistent and making it harder to spot performance issues.
800W/m2
![Page 38: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/38.jpg)
Problem Sky ConditionsCause variability in PV measurement results
![Page 39: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/39.jpg)
Max power point
I-V Curve Signatures of PV Problems
Any reduction of the knee of the curve
means reduced output power.
Current (A)
Voltage (V)
Isc
Voc
Shunt losses*
Series losses**
Mismatch losses (incl. shading)
Normal I-V curve
Reducedcurrent
Reducedvoltage
Conventional measurements do not reveal many of these effects.
![Page 40: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/40.jpg)
Isc
Voc
Useful diagnosticsFill Factor, Current Ratio, Voltage Ratio
Current
Voltage
Fill Factor =Imp x Vmp (watts)
Isc x Voc (watts)
aSi: 0.50 – 0.70
xSi: 0.75 – 0.85
GaAs: 0.85 – 0.9
=
Current ratioImp/Isc
Voltage ratioVmp/Voc
Imp
Vmp
Max Power Point
![Page 41: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/41.jpg)
String of Field-aged, Early TF ModulesDegraded fill factor, lower output power
Array-as-sensor mode for viewing relative changes in curve shape
![Page 42: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/42.jpg)
0
1
2
3
4
5
6
7
8
0 50 100 150 200 250 300 350 400
Voltage - V
Cu
rren
t -
A
String 4B14
String 4B15
Troubleshooting exampleAnomalous slope in string I-V caused by single high-resistance module
![Page 43: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/43.jpg)
Example of a series resistance failureinside a module J-box
Probably failure mode:
Heat cycling � bond degradation � resistive heating
![Page 44: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/44.jpg)
Dropped Cell String
• Shorted bypass diode, or
• Mismatch causing diode to turn on
when current starts flowing
![Page 45: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/45.jpg)
Partially shaded residential arrayMeasure the single string mounted along lower edge of roof
![Page 46: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/46.jpg)
I-V Curve of the partially shaded stringSingle string mounted along lower edge of roof
Approximately 40% reduction in string’s output power
![Page 47: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/47.jpg)
What bypass diodes doExample: Normal current flow in an un-shaded PV Module
+
Cell String
Cell String
Cell String
BypassDiodes
Bypass diode turns on when the shaded cell(s) can no longer pass as much current as the non-shaded cells.
![Page 48: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/48.jpg)
Shade one cell
+
Cell String
Cell String
Cell String
BypassDiodes
Bypass diode turns on when the shaded cell(s) can no longer pass as much current as the non-shaded cells.
![Page 49: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/49.jpg)
I-V Curve of a Partially Shaded String
• Multiple ‘knees’ � multiple power peaks
• Peaks evolve as conditions change
• Inverter tries to find and track the highest peak
Current
Voltage
Isc
Voc
Power
![Page 50: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/50.jpg)
Shade 2 cells in the same cell-stringSingle module with 72 cells and 3 bypass diodes
Shading one
cell string
drops 1/3 of
PV module
voltage and
power
![Page 51: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/51.jpg)
Shade 2 cells in adjacent cell-stringsSingle module with 72 cells and 3 bypass diodes
The same
amount of
shade,
oriented
differently,
drops 2/3 of
PV module
voltage and
power.
![Page 52: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/52.jpg)
What is the PV Analyzer all about?
•Single measurement for each string
•Most complete performance measurement possible
•Measures each string’s max power independently
•Built-in PV models give instant performance check
•Does not require bringing the inverter online
•Software tool automates data analysis
•Helps us learn to “think like a PV array”
I
V
Commission and troubleshoot PV arrays faster and better
![Page 53: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/53.jpg)
Topics
• PV array performance verification
• Introduction to I-V curves
• The Solmetric PVA-600 PV Analyzer
• Demo of the PV Analyzer user interface
• Commissioning & troubleshooting PV array performance
• Meg testing with the Megger® MIT430
![Page 54: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/54.jpg)
Insulation Resistance Testing of PV ArraysWhere are we?
• Best practice is to test all systems during commissioning and maintenance
• Today, meg testing is not done on all commercial systems, and is rare in residential systems.
• Source circuits are often tested in aggregate
– Individual strings are tested only if aggregate resistance is low
• Methods for subarray test are not standardized or widely understood
– Best reference is the “re-wrenches” blog (Home Power Magazine)
• Trend is toward specifying meg testing for commercial systems
• Insulation problems will be much more common as PV systems age
![Page 55: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/55.jpg)
Preparation: Open the DC Disconnect � Lift string fuses � Lift negative feeder cable(s)
Lift
Meg Testing at the Subarray Level
Lift
Example assumes a
negative-grounded array
Lift
Combiner box
![Page 56: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/56.jpg)
Preparation: Open the DC Disconnect � Lift string fuses � Lift negative source cable
Lift Lift
Meg Testing at the String Level
Example assumes a
negative-grounded array
Lift
![Page 57: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/57.jpg)
Saving Meg Test Data in the PV Analyzer
1
2
3
4
5
6
500
500
500
500
500
500
1.604
1.003
1.427
1.769
1.191
0.826
C1 S1
C1 S2
C1 S3
C1 S4
C1 S5
C1 S6
Me
g
Te
st
![Page 58: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/58.jpg)
5-Minute PV Analyzer Training Videoshttp://www.solmetric.com/videos1.html
![Page 59: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/59.jpg)
Free I-V Curve Posterhttp://www.solmetric.com/specialoffers.html
![Page 60: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/60.jpg)
SolarPro Magazine, Aug/Sep 2011
![Page 61: New Tools for PV Array Commissioning and Troubleshootingresources.solmetric.com/get/Solmetric-PVA-Webinar-Feb-9-2012.pdf · New Tools for PV Array Commissioning and Troubleshooting](https://reader031.vdocument.in/reader031/viewer/2022022003/5aa2b16e7f8b9aa0108d89a4/html5/thumbnails/61.jpg)
New Tools for PV Array
Commissioning and Troubleshooting
Paul Hernday
Applications Engineer
cell 707-217-3094
February 9, 2012