H Gopalan
Editor, www.orthopaedicprinciples.com
Expert Advisor, www.myorthoevidence.com
SICOT India ICL Course Director
![Page 2: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/2.jpg)
Patient Specific Instrumentation
• Customisedinstruments for every patient
•Need for CT/MRI earlier
• Reduces inventory
![Page 3: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/3.jpg)
Level 2 Meta analysis•7 RCT
• Higher incidence of tibial component malaligment in PSI
Thienpont E et al..BJJ Aug 2014
![Page 4: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/4.jpg)
Computer Navigation in TKA
![Page 5: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/5.jpg)
Navigation: 21 RCTsMechanical Axis Deviation, Femoral and
Tibial Component Alignment: < 3 degree
CAS : <3 degrees
CAS took longer time
![Page 6: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/6.jpg)
Lutzner J et al.. 2013
• Superior Alignment < 3 degree: Can it affect revision rates?
•Cost effectiveness
![Page 7: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/7.jpg)
High Flexion in TKA
![Page 8: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/8.jpg)
•Choi WC JBJS Am 2010•Kim JBJS Am 2009
•Nieuwenhuijse JBJS Am 2013 RSA- Implant migration.
![Page 9: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/9.jpg)
NO DIFFERENCE
• Knee Society scores• HSS Knee Score• WOMAC • SF- 36 scores
![Page 10: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/10.jpg)
Oxinium
• Surface coating of Oxinium
•Coating is oxidised Zirconium, superior wear properties
•? Wear rates
![Page 11: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/11.jpg)
Kim WH 2012
KSS, WOMAC, ROM, UCLA score for post op mobility
Osteolysis, Patellar tilt, Subluxation,
Wear particle analysis: Aspiration
NO DIFFERENCE
![Page 12: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/12.jpg)
Cementless TKA
• Younger patients
• Circumvent Asceptic Loosening
•Prosthesis survival
![Page 13: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/13.jpg)
Cementless TKA
• 93 patients
• 9 year survival
• 93.7 % in cementless Vs 90 % cemented group
Lizuar Utrill A et al.. 2014
![Page 14: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/14.jpg)
CoC Vs CoP
•Reduced wear rates compared to metal on polyethylene
• CoC- squeaking incidence 2- 7%
![Page 15: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/15.jpg)
CoC Vs CoP: Kim YH 2011
• 200 patients
•Harris hip score, UCLA, WOMAC
• Similar Function and Radiological Outcome
![Page 16: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/16.jpg)
Trabecular Metal
•Cementless TKA
• 145 patients
•Trabecular Metal Vs Standard cemented TKA
•KSS, WOMAC better in trabecularmetal cemetless group
Fernandez- Fairer M et al.. 2013
![Page 17: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/17.jpg)
Uncemented Stem THA
• Uncemented Vs Cemented Hemiarthroplasty
• Expensive
•? Better function, Easier Revision
![Page 18: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/18.jpg)
Cemented Vs Uncemented HA•115 patients in each
• Uncemented group: better Harris hip scores at 5 years
• Periprosthetic fracture: 7.4% in uncementedgroup Vs 0.9% in the cemented group
![Page 19: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/19.jpg)
Accelerometer- Portable Device•100 patients
• No difference tibialcomponent alignment
• Higher time for tibial resection
•Better restoration of mechanical axis
![Page 20: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/20.jpg)
![Page 21: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/21.jpg)
Five Innovations Gender Specific Knee Replacement
Modular necks in THA
High flexion Knee Replacement
Ceramic on Ceramic
Uncemented Monoblock cups
![Page 22: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/22.jpg)
Expose large number of patients to Unknown Implants
Introduction into commercial market
Adverse effect profile
![Page 23: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/23.jpg)
MoMs
![Page 24: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/24.jpg)
![Page 25: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/25.jpg)
Evidence Based Reviews
![Page 26: Newer technology in arthroplasty-hat’s the evidence](https://reader033.vdocument.in/reader033/viewer/2022060205/55a2057c1a28abe9648b4662/html5/thumbnails/26.jpg)
Evidence Based Practice
Don’t be the first to use new Technology and don’t be the last to ditch it.