NEX 24. 24 kV switchgear May 2010. Applications NEX offer Range description Remote control Continuity of service. Agenda. Applications. A solution for MV primary substations. NEX 24 is present on all electrical distribution markets: energy infrastructure: hospitals, airports - PowerPoint PPT PresentationTRANSCRIPT
NEX 24
24 kV switchgear
May 2010
Schneider Electric 2- MV LoB- G. Allison / M. Maitre – May 2010
ApplicationsNEX offer Range descriptionRemote control Continuity of service
Agenda
Schneider Electric 3- MV LoB- G. Allison / M. Maitre – May 2010
Applications
Schneider Electric 4- MV LoB- G. Allison / M. Maitre – May 2010
●NEX 24 is present on all electrical distribution markets:● energy
● infrastructure: hospitals, airports
● industry: cement plants, water
A solution for MV primary substations
Schneider Electric 5- MV LoB- G. Allison / M. Maitre – May 2010
●NEX 24 for standard applications
Simplicity
Schneider Electric 6- MV LoB- G. Allison / M. Maitre – May 2010
● NEX 24 closer to you● Proximity:
●well-proven technical support●quick response to request for quotes and tenders●optimal solution with advanced characteristics●dedicated engineering
● A complete range:●Circuit breaker●voltage transformers / current transformers●earthing switch● …
Flexibility
Schneider Electric 7- MV LoB- G. Allison / M. Maitre – May 2010
NEX 24 offer
Schneider Electric 8- MV LoB- G. Allison / M. Maitre – May 2010
Characteristics
●Definition:● draw-out metal-enclosed switchgear functional units
● indoor installation
● air insulated cubicle (AIS)
●Electrical data:● rated insulation voltage: 24 kV
● lightning surge withstand: 125 kV peak
● nominal current: 630 A to 2000 A
● main circuit short-time withstand current:
up to 25 kA 3s
● earthing switch short-time withstand current:up to 25 kA 3s
● internal arc withstand: up to 25 kA 1s ALFR
Schneider Electric 9- MV LoB- G. Allison / M. Maitre – May 2010
●Vacuum breaking technology●24 kV voltage level●Two cubicle widths for the range
Characteristics
800mm 1000mm
2300
mm
Schneider Electric 10- MV LoB- G. Allison / M. Maitre – May 2010
Performances
NEX 24
24 kV
A
kA
630 1250 2500
16
25
31,5
40
50
2000
Schneider Electric 11- MV LoB- G. Allison / M. Maitre – May 2010
Installation parameters
Protection index
IP3X - IP4X
A B C D
NEX 24 600 1 810 4000 600
Schneider Electric 12- MV LoB- G. Allison / M. Maitre – May 2010
Top bar connectionBottom cable connection Top cable connection
Installation and connection type
Schneider Electric 13- MV LoB- G. Allison / M. Maitre – May 2010
●Safety of use for all against electrical, mechanical and thermal effects of a fault:
●each compartment is insulated from the othersby metallic earthed walls
● 3 compartments :
●cable connection
●circuit-breaker
●busbar
● Low Voltage cabinet
NEX 24 complies with IEC 62271-200 standard
Schneider Electric 14- MV LoB- G. Allison / M. Maitre – May 2010
●NEX 24 range complies with international IEC 62271-200 standard governing metal-enclosed switchgear for AC current for rated voltages above 1kV and up to and including 52 kV
●Standards: ● IEC 60694 IEC62271-1 : Common clauses for HV switchgear● IEC 62271-200 (60298): AC metal-enclosed switchgear and controlgear for rated voltages above
1kV and up to and including 52 kV
● IEC 62271-100 (60056): HV AC circuit-breakers ● IEC 60470: HV AC contactors● IEC 60265-1: HV switches● IEC 60282-2: HV fuses● IEC 62271-102 (60129): AC disconnector and earthing switch● IEC 60255: Measurement relay and protection device● IEC 60044-1: Current transformers● IEC 60044-2: Voltage transformers● IEC 60044-8: Electronic current transformers● IEC 60529 : Degrees of protection provided by enclosures● IEC 61958: Voltage Presence Indication Systems
Standards conformity
Schneider Electric 15- MV LoB- G. Allison / M. Maitre – May 2010
●Normal operating conditions:● Indoor equipment
● temperature -5 to +40°C
● altitude 1000 m
● humidity 95 % over 24 h
90 % over 1 month
●Specific conditions:● Possibility to adapt equipment
according to environmental requirements
Standards conformity
Schneider Electric 16- MV LoB- G. Allison / M. Maitre – May 2010
●All operations are carried out with the door closed●Access to live parts is impossible due to protective flaps●Voltage presence indicator●Position indicator linked to device physical position●Instructions in symbol form:
● without text
● Standardized symbols
●Locking systems:● by padlock
● by key-lock
● electromagnetic
An efficient and safe interface
Schneider Electric 17- MV LoB- G. Allison / M. Maitre – May 2010
NEX 24 25kA 1s (AFLR)
Modèle Performance
NEX 24 internal arc withstand performances
Schneider Electric 18- MV LoB- G. Allison / M. Maitre – May 2010
●Architecture based on safe access to compartments:● protection of operators in the event of internal arcing
● complies with 5 criteria:●les correctly secure doors and covers do not open●no fragmentation of the enclosure occurs within the time specified for the test●arcing does not cause holes in the accessible sides up to a height of 2m●indicators do not ignite due to the effect of the hot gases●the enclosure remains connected to its earthing point
●Satisfies continuity of supply requirements:● maintenance with power on (LSC2B)
●secured access to compartments with power on thanks to separate busbarand cable compartments
● the MV parts are compartmentalised by earthed metallic partitions and shutters
Protection of operators and continuityof supply
Schneider Electric 19- MV LoB- G. Allison / M. Maitre – May 2010
●Preventive and reduced maintenance● Sepam protection unit:
●sum of currents broken
●event memorisation
●control circuit monitoring
●self-monitoring
●Simplicity of maintenance● Periodic simple operation checking
● Cleaning and lubrication every 5 to10 years
Ease of maintenance
Schneider Electric 20- MV LoB- G. Allison / M. Maitre – May 2010
Range description
Schneider Electric 21- MV LoB- G. Allison / M. Maitre – May 2010
A complete range
●A cubicle for each function
Feeder
IF cubicle
Incomer
IF cubicle
Coupling
BC and RF(RW)cubicles
Busbarearthing
BM cubicle
Load-break
LB cubicle
Feeder
IF cubicle
Schneider Electric 26- MV LoB- G. Allison / M. Maitre – May 2010
Remote control
Schneider Electric 27- MV LoB- G. Allison / M. Maitre – May 2010
●Sepam multi-function protection relay range:● series 20 Sepam for standard applications:
– Current or voltage measurement
● series 40 Sepam for advanced applications– All measurements: current and voltage, power, energy
● series 80 Sepam for specific and customized applications– All measurements: current and voltage, power, energy
●Sepam, a solution adapted to your operations:● Real time data comprising circuit-breaker status
● Quick isolation of a failed network component and network configuration from the remote control centre
A built-in protection and monitoring chain
Schneider Electric 28- MV LoB- G. Allison / M. Maitre – May 2010
●To supply protection, metering and monitoring devices
●A full preferential current transformer range, harmonized with digital protection devices, to simplify determination of accuracy characteristics:
Instrument transformers
ARJP, ARJH, ARJM ARJAtype current transformer
TLP 160 / 190current transformer
VRS3 voltage transformer
Schneider Electric 29- MV LoB- G. Allison / M. Maitre – May 2010
●The VPIS (Voltage Presence Indicator System) is located on the front panel of the functional unit and in the immediate proximity of the earthing switch operating mechanism
Voltage prescence indicator: an effective and safe interface
Schneider Electric 30- MV LoB- G. Allison / M. Maitre – May 2010
NEX 24 Transparent Ready option: ● Access to predefined Web pages containing information on:
●Current, power, energy, history, …
● Uses a simple Web server and the local TCP / IP network
Permanent monitoring
Schneider Electric 31- MV LoB- G. Allison / M. Maitre – May 2010
Continuity of supply
Schneider Electric 32- MV LoB- G. Allison / M. Maitre – May 2010
Draw-out devices – circuit breaker
Schneider Electric 33- MV LoB- G. Allison / M. Maitre – May 2010
●Evolis circuit breaker● Evolis circuit breaker for cubicles IF and BC 24 kV / 2000 A
● RI operating mechanism
Vacuum breaking draw-out devices
Schneider Electric 34- MV LoB- G. Allison / M. Maitre – May 2010
The earthing and disconnector trucks
Earthing truck● is a safety feature which allow
the cubicles busbar to be earthed
Disconnector truck● enables the upper and lower part
of the cubicle to be short-circuited.
Schneider Electric 35- MV LoB- G. Allison / M. Maitre – May 2010
A guaranteed high level of availability
●The result of experience of more than 2000 items of switchgear installed world-wide
●Incorporation of innovating solutions designed from tried and tested equipment:
● High performances breaking devices
● Digital control, monitoring and protection chains
● Enclosures able to withstand internal arcing
Schneider Electric 36- MV LoB- G. Allison / M. Maitre – May 2010
References the world over in all sectors of activity●Infrastructures
● Hotel Méridien Bangalore (India)
● New Airport of Bangkok (Thailande)
● Sous-Station du port de Lattakia (Syria)
●Energy● North Delhi Power Ltd (India)
● Otway, Port campbell offshore extraction de gaz (Australie)
● Raffinerie de pétrole Empresa (Colombie)
● Technip Qatargas (Qatar)
●Industry● Usine Hyflux de désalination d’eau (Singapour)
● Station de Pompage d’eau Bir Hal Hacham (Syrie)
● Mines d’or du nord de Mara (Tanzanie)
Schneider Electric 37- MV LoB- G. Allison / M. Maitre – May 2010
●Eliminate sensitive substances●Facilitate treatment of products at end of life●Continuously enhance the environmental performance of production
sites
97%
of Schneider Electric industrial sites are ISO 14001
93% of global products are eco-designed
Eco-design and eco-produce
Schneider Electric 38- MV LoB- G. Allison / M. Maitre – May 2010
●NEX 24● Provides optimum continuity of supply
● Proximity, flexibility
● Facilitates and simplifies maintenance
Conclusion