noise stop tape extend your outdoor lifestyle · e [email protected] queensland t 07 3717 4700...

2
only Laserlite ® has the technology Laserlite ® is the only polycarbonate corrugated sheet product in Australia featuring Advanced Weatherguard™ technology, a special protective material that is warranted to Extend the life of the sheet by up to 50% # Maintain sheet colour and clarity up to 50% longer # Provide 99.9% protection from UV rays up to 50% longer # Resist 25% larger hailstones # With unrivalled technology and superior performance, it’s clear why Laserlite ® is part of the Australian outdoor lifestyle. Comfort Cool™ keeps you cool and comfortable. feature Comfort Cool Technology, special properties in the Up to 50% better heat reduction than standard corrugated sheet # reduced glare for ultimate comfort # As compared to some other polycarbonate corrugated sheet products. How it works How it works UV rays, wind, hail and rain have the potential to make polycarbonate resins brittle and lose colour over time. Advanced Weatherguard TM protects the sheet and protects from harmful UV radiation. Infra red light emitted by the sun passes through polycarbonate sheet making it warm underneath. Comfort Cool letting visible light through with less glare. Up to 50% better heat reduction than standard corrugated sheet # * colour selection. Slight colour variation may occur between production runs. Transmitted light and colour may vary in intensity depending on weather conditions. The information contained in this brochure is to the best of our knowledge accurate, but all recommendations are made without any warranty whatsoever, since the conditions of use are beyond our control. This brochure cancels and supersedes all previous publicised information. The company reserves the right to alter and revise, without notice, the information contained herein. www.laserlite.com.au extend your outdoor lifestyle Save 50% installation time 1 3 4 2 Easy to install, Laserlite ® has a quality range of accessories to ensure a When installed against a wall Laserlite ® One Shot ® Time Saving Fixing System saves 50% installation time as no pre-drilling is required. They also feature a Class 4 coating for superior corrosion resistance and suitability for coastal areas. New South Wales T 02 9677 9900 F 02 9677 9500 E [email protected] Victoria T 03 8791 8000 F 03 8791 8088 E [email protected] Queensland T 07 3717 4700 F 07 3717 4777 E [email protected] South Australia T 08 8444 9666 F 08 8444 9600 E [email protected] Western Australia T 08 9240 6655 F 08 9240 8877 E [email protected] Tasmania T 03 6288 6000 F 03 6288 6010 E [email protected] Prevents rain,dust and wind entering the eaves Barge capping Prevents wind & rain entering the gable ends Metal ridge capping Prevents roof leaking at apex Prevents leaking at walls and facias Prevents leaking at walls and facias 1 2 3 4 Noise stop tape Reduces creaking the solution for a

Upload: others

Post on 17-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

only Laserlite® has the technologyLaserlite® is the only polycarbonate corrugated sheet product in Australia featuring

Advanced Weatherguard™ technology, a special protective material that is warranted to• Extend the life of the sheet by up to 50%#• Maintain sheet colour and clarity up to 50% longer#• Provide 99.9% protection from UV rays up to 50% longer#• Resist 25% larger hailstones#With unrivalled technology and superior performance, it’s clear why Laserlite® is part of the Australian outdoor lifestyle.

Comfort Cool™ keeps you cool and comfortable.

feature Comfort Cool™ Technology, special properties in the

• Up to 50% better heat reduction than standard corrugated sheet#• reduced glare for ultimate comfort

# As compared to some other polycarbonate corrugated sheet products.

How it works How it worksUV rays, wind, hail and rain have the potential to make polycarbonate resins brittle and lose colour over time. Advanced WeatherguardTM protects the sheet and protects from harmful UV radiation.

Infra red light emitted by the sun passes through polycarbonate sheet making it warm underneath. Comfort Cool™letting visible light through with less glare.

Up to 50% better heat reduction

than standard corrugated

sheet#

* colour selection. Slight colour variation may occur between production runs. Transmitted light and colour may vary in intensity depending on weather conditions. The information contained in this brochure is to the best of our knowledge accurate, but all recommendations are made without any warranty whatsoever, since the conditions of use are beyond our control. This brochure cancels and supersedes all previous publicised information. The company reserves the right to alter and revise, without notice, the information contained herein.

www.laserlite.com.au

extend your outdoor lifestyle

Save 50% installation

time

1

3

4

2Easy to install, Laserlite® has a quality range of accessories to ensure a

When installed against a wall

Laserlite® One Shot® Time Saving Fixing System saves 50% installation time as no pre-drilling is required. They also feature a Class 4 coating for superior corrosion resistance and suitability for coastal areas.

New South Wales T 02 9677 9900 F 02 9677 9500 E [email protected]

Victoria T 03 8791 8000 F 03 8791 8088 E [email protected]

Queensland T 07 3717 4700 F 07 3717 4777 E [email protected]

South Australia T 08 8444 9666 F 08 8444 9600 E [email protected]

Western Australia T 08 9240 6655 F 08 9240 8877 E [email protected]

Tasmania T 03 6288 6000 F 03 6288 6010 E [email protected]

Prevents rain,dust and wind entering the eaves

Barge cappingPrevents wind & rain entering the gable ends

Metal ridge cappingPrevents roof leaking at apex

Prevents leaking at walls and facias

Prevents leaking at walls and facias

1 2

3 4

Noise stop tape Reduces creaking

the solution for a

• Lifetime Platinum Warranty* • Lifetime Platinum Warranty*

greca corrugated greca corrugated

platinum ice gun metal

clear opal cream bronze tint

grey tint

Laserlite® 2000 Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m 4.8m, 5.4m, 6.0m, 7.2m, 9.0m

Sheet width Corrugated 840mm Greca 810mm 5 - rib 830mm

Cover width Corrugated 755mm Greca 760mm 5 - rib 762mm

‡ # As compared to some other polycarbonate corrugated sheet products.

The classic, high performing Laserlite® range.

Performance & reliability Ultimate comfort

Laserlite® 3000Lengths available - 1.8m, 2.4m, 3.0m, 3.6m, 4.2m, 4.8m, 5.4m, 6.0m, 7.2m, 9.0m

Sheet width Corrugated 840mm Greca 810mm

Cover width Corrugated 755mm Greca 760mm

PRODUCT TECHNOLOGIES PRODUCT TECHNOLOGIES

1. SELECT PRODUCT 1. SELECT PRODUCT

2. SELECT COLOUR 2. SELECT COLOUR

3. SELECT PROFILE 3. SELECT PROFILE

4. SELECT LENGTH 4. SELECT LENGTH

Up to 50% better heat reduction

performancethan standard

corrugated sheet!#

for the ultimate outdoor lifestyle experience.

With Comfort CoolTM Technology

Light 93% 49% 43% 38% 19%Transmission % Heat 0% 52% 62% 33% 47%Reduction % ‡

Light 18% 47% 16%Transmission % Heat 69% 63% 66%Reduction %‡

5 - rib

clear opal cream bronze tint grey tint platinum ice gun metal

clear opal creambronze tint

grey tint

platinum ice gun metal

MORE LIGHT LESS LIGHT

COOLERWARMER

Light level

Comfort level

Light level

Comfort level

MORE LIGHT LESS LIGHT

COOLERWARMER

Eave In�ll StripsPrevent rain, dust and wind entering eaves

Noise Stop TapeReduce creaking

Safety Recommendations- Always exercise extreme care when walking on a roof.- Never walk on or apply your load directly to sheeting. - In particular consider all safety requirements when working at heights above 2m.- For safety reasons we recommend the use of safety mesh for installations above 3m.- Use appropriate personal protective equipment (PPE) such as safety footwear, glasses and gloves.- All safety practices must comply with the applicable local building and/or work cover code(s).- We do not recommend the collection of drinking water from any roof without Check with your local water authority for further advice.

CAUTION: To maximise the life cycle of your Laserlite® ® recommends avoiding exposure of polycarbonate sheeting to excess heat from patio heaters. Maintain a distance of 1 metre minimum between the sheets and the heater with adequate ventilation at all times and temperature to below 90°C beneath the sheeting. If the temperature rises above 90°C, remove the heater immediately.

Carefully read all installation instructions before you start.• For installation in cyclonic regions, contact your nearest Laserlite o�ce for special instructions.

Safety Recommendations

Installation InstructionsPurlin end span spacing

(refer Table X)

Purlin mid span spacing (refer Table X)

Barge Capping

Laserlite screwsand weatherseals(refer Table Y for spacing)

Apron FlashingPurlins

Rafters

Fascia

Foam In�ll

Laserlite Polycarbonate RoofPurlin

Back Channel Flashing

Gutter

Purlin end span spacing (refer Table X)

Purlin mid span spacing (refer Table X)

Barge Capping

Laserlite screwsand weatherseals(refer Table Y for spacing)

Apron FlashingPurlins

Rafters

Fascia

Foam In�ll

Laserlite Polycarbonate RoofPurlin

Back Channel Flashing

Gutter

Table X – Maximum Purlin Spacings

Pro�le End Span Mid Span

Roma 800mm 1000mm

Greca 900mm 1200mm

Trimdek 900mm 1200mm

Table Y – Fixing Spacings

Pro�le End Purlins Mid Purlins

Roma Every 2nd crest Every 3rd crest

Greca Every 2nd crest Every 3rd crest

Trimdek Every crest Every crest

18mm

thickness = 0.8m m

thickness = 0.8m m

thickness = 0.8m m

760mm

76mm

18mm

840mm

760mm

76mm

815mm

25mm

25mm

25mm

60mm

20mm

13mm

29mm

762mm

191mm830mm

170˚

25mm

cover width

sheet width

cover width

sheet width

cover width

sheet width

Greca

Trimdek

Product PerformanceShading Co-e�cient Ratio (SC)

Light T ransmission (L T)

Clea

r 1.

01

Bron

ze T

int

0.68

Grey

Tin

t 0.

55

Opa

l 0.

53

Oce

an B

lue

0.

50

Gum

leaf

0.

43

Arct

ic Ic

e

0.39

Ston

e 0.

36

Gun

Met

al

0.35

Ivor

y 0.

35

Satin

Sag

e 0.

34

Met

allic

Bro

nze

0.34

Satin

Cre

am

0.33

Stee

l 0.

32

Oliv

e M

ica

0.

31

Plat

inum

0.

31

Clas

sic C

ream

0.

30

Clea

r 93

%

Opa

l 56

%

Satin

Cre

am

51%

Arct

ic Ic

e

44%

Bron

ze T

int

35%

Ivor

y 35

%

Clas

sic C

ream

33

%

Ston

e 29

%

Satin

Sag

e 28

%

Grey

Tin

t 19

%

Gum

leaf

19

%

Oce

an B

lue

18

%

Plat

inum

17

%

Oliv

e M

ica

15

%

Met

allic

Bro

nze

15%

Stee

l 15

%

Gun

Met

al

13%

XPT 2000 Apollo

More Light Less Light

Warmest Coolest

Weight Roma Greca Trimdek

Kg per Lineal Metre 0.92 0.93 0.92

Kg per m2 1.10 1.13 1.11

Available Sizes Standard lengths in metres: 1.8, 2.4, 3.0, 3.6, 4.2, 4.8, 5.4, 6.0, 7.2 Lengths up to 10 metres can be ordered (conditions apply)

Roma

Shading Co-e�cient (SC): A ratio of the warming e�ect of the sun’s rays through a sheet divided by the sun’s warming e�ect through 3mm �oat glass (300-2500nm). The lower the �gure the cooler it is under the sheet.

Table Z – Side Laps

Roma – 1 1/2 corrugations

Greca – 1 corrugation

Trimdek – 1 corrugation

Prevailing Wind Direction

Product RangePro�les

Light Transmission (LT): % of visible light transmission (400-700nm) that passes through the sheet. The lower the �gure the less light passes through the sheet.

Ensure that your roof pitch is at least 5 º, i.e. 88mm rise per lineal metre. This will ensure adequate water run o�.

Allow for ventilation, particularly at the highest point, to minimise heat build-up and provide air circulation. Good ventilation will also minimise condensation in cold weather. For roo�ng, purlin/batten spacings should be no more than those shown in Table X – Maximum Purlin Spacings. For curved structures, the maximum purlin spacing should be 750mm and a minimum radius of 6000mm for Roma and Greca pro�le and 14000mm for Trimdek pro�le. For walls, nogging spacings should be no more than 1200mm. Use Laserlite Noise Stop Tape on all battens, purlins or noggings to minimise the noises associated with expansion and contraction. Ensure the UV surface protected side faces the sun. This is the side of the label and the inkjet marking. When installed as a wall or fence it is recommended that the UV protected side is facing the most sun. The life of the sheet may be shortened and discolouration may occur due to the unprotected side being exposed to UV radiation. The sheet can be easily cut with a pair of shears, a �ne-toothed handsaw or a circular saw with a cut-o� blade suitable for plastic. In normal conditions, use the �xing spacings shown in Table Y – Fixing Spacings. As a guide, you will need approximately 7 �xings per lineal metre. This depends on your purlin spacings and wind conditions. In high wind areas �x Roma and Greca on every second corrugation on each purlin/batten. It is suggested that barge capping be used. Fix the sheet through the crests for roo�ng with Laserlite One-Shot Fixings and through the valleys for walls with Laserlite Fixings for Cladding or Laserlite Standard Fixings. For roof laying, start with the lower sheets �rst, keeping side laps away from prevailing wind. Allow an overhang of 50mm. Temperature changes will cause expansion and contraction, so make allowances for thermal movement. Resistance to movement can cause buckling. To ensure maximum performance of the sheet, and to avoid buckling, it is necessary to oversize the holes and centre the �xings. It is recommended that Laserlite One-Shot Fixings are used. They come complete with their own hole saw that cuts an expansion hole as you drill. The screw is centred every time and the cutter holds the plug of material removed. If using Laserlite Fixings for Cladding or Laserlite Standard Fixings, pre-drill your �xing holes. Use a 10mm drill for sheets up to 4.2m long and a 12mm drill for sheets longer than 4.2m. Fix the sheet through the centre of the pre-drilled holes, perpendicular to the purlins/battens. A (5/16”) Drill hex driver bit should be used. Only tighten the �xings enough to prevent rattling. Over-tightening may cause distortion and undue stress with possible failure resulting. Use only Laserlite branded �xings as these are designed to be compatible with Laserlite Polycarbonate Roo�ng. Any failure of the sheet due to �xings other than Laserlite branded will void the Laserlite warranty. Side laps will di�er by pro�le. Install as shown in Table Z. End overlaps should be 150mm for steep pitch or 200mm for shallow pitch.

1

2

3

4

5

6

7

8

9

10

1 metre

88m

m

264m

m

3 metres

1 metre

88m

m

264m

m

3 metres

CAUTION – To maximise the life of your Laserlite roo�ng, Laserlite recommends to avoid exposing your polycarbonate sheeting to excess heat from patio heaters. Laserlite recommends a distance of 1m is kept between the sheets and the heater, adequate ventilation at all times and temperature to be below 90 ºC beneath the sheeting. If temperature underneath your sheet rises above 90 ºC, immediately remove the patio heater from underneath the polycarbonate sheeting.

• Always exercise extreme care when walking on any roof. • Never walk on or apply a load or your weight directly to sheeting. • In particular consider all safety requirements when working at heights

above 2m. • For Safety precautions we recommend the use of safety mesh for

installations above 3m. • Use appropriate personal protective equipment (PPE) such as safety

footwear, safety glasses and gloves. • All safety practices must comply with the applicable local building

and/or work cover code(s).

• Refer to Safety Recommendations. • Installations must comply with the applicable building code. • We do not recommend the collection of drinking water from any roof

without appropriate precautions and �ltration. Check with your local water authority for further advice.

StepPurlins & accessories

Step

1. Ensure that your roof pitch is at least 5°, ie. 88mm rise per lineal metre.This will ensure adequate water run off.

2. Allow for ventilation, particularly at the highest point, to minimise heat build-up and provide air circulation. Good ventilation will also minimise condensation in cold weather.

be no more than those shown in Table X - Maximum Purlin Spacings. For curved structures, the maximum purlin spacing should be 750mm and a minimum radius of

spacings shoud be no more that 1200mm. Use Laserlite® Noise Stop Tape on all battens, purlins or noggings to minimise the noises associated with expansion and contraction.

4. Lay Laserlite® Noise Stop Tape to avoid creaking.

5. Lay Laserlite® at eaves to avoid rain,dust & wind entering the eaves.

metal back channel with prior to laying sheet.

1. Ensure that the UV surface protected side faces the sun. This is the side of the label and the inkjet marking. When installed as a wall or fence it is recommended that the UV protected side is facing the most sun. The life of the sheet may be shortened and discolouration may occur due to the unprotected side being exposed to UV radiation.

Prevailing Wind Direction

5. To ensure maximum performance of the sheet, and to avoid buckling, it is necessary to

recommended that Laserlite® One Shot®are used. They come complete with their own hole saw that cuts an expansion hole as you drill. The screw is centred every time and the cutter holds the plug of material removed. If using Laserlite®

holes. Use a 10mm drill for sheets up to 4.2m long and a 12mm drill for sheets longer than 4.2m. Fix the sheet through the cerntre of the pre-drilled holes, perpendicular to the purlins/battens. A (5/16”) Drill hex driver bit should be

rattling. Over tightening may cause distortion and undue stress with possible failure resulting. Use only Laserlite® are designed to be compatible with Laserlite®

® branded will void the Laserlite® warranty.

shown in Table Z - Fixing spacings. As a guide, you will need approximately 7

purlin spacings and wind conditions. In high

second corrugation on each purlin/batten. It is suggested that barge capping be used. Fix the sheet through the valleys for walls with Laserlite® Standard Fixings.

Using One Shot® eliminates requirement for pre-drilling.

6. End overlaps should be 150mm for steep pitch or 200mm for shallow pitch.

APEX ROOF - Fit metal barge capping to the edge of sheet and metal ridge capping to the apex.

UNDER A GUTTER - Fit back channel

prior to laying sheets and metal barge capping to edge of sheet.

AGAINST A WALL/FASCIA - Fit metal barge capping to edge of sheet and metal apron

Step

Table X - Maximum Purlin Spacings Span Mid Span

Corrugated 800mm 1000mmGreca 900mm 1200mm5 Rib 900mm 1200mm

Table Z - Fixing Spacing Purlin Mid Purlins

Corrugated every 2nd crest every 3rd crestGreca every 2nd crest every 3rd crest5 Rib every crest every crest

Corrugated - 1 1/2 corrugations

Greca - 1 1/2 corrugations

5 Rib - 1 corrugations

2. The sheet can be easily cut with a pair of

saw with a cut-off blade suitable for plastic.

3. For roof laying, start with the lower

prevailing wind. Allow an overhang of 50mm. Temperature changes will cause expansion and contraction, so make allowances for thermal movement. Resistance to movement can cause buckling.

shown below:

Table Y - Side laps

for various installations

Installation Guide1

2

3