2 Non-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 7 97,1 10 57,5 Ø 5,2 (2x) R4 M5 3,3 8,3 5 R3 18,1 Read head CES-A-LSP-... Dimension drawing Read head CES-A-LSP-... M5 plug connector, 3-pin or hard-wire encapsulated cable Active face Optimized for aluminum profile mounting LED for the indication of the door position Y 15 20 25 30 5 Z X 5 15 20 25 30 -20 -25 -30 -45 -50 -55 -60 -65 -40 -35 -15 -10 -5 25 30 15 10 45 50 55 60 65 35 5 20 10 40 10 Typical operating distance Installed in aluminum profile 45 x 45 mm Pin assignment H11 H12 SH1 BN WH 1 3 4 Screen Read head CES-A-LSP CES-AZ... For connection cable see page 64 For possible combinations see page 24 Attention: The operating distance may vary de- pending on the background material and installation situation. Important: Actuators must be ordered sepa- rately! See page 42. Ordering table Series Cable/connection type/version Cable length [m]/description Order no. / item CES-A-LSP-... V Cable PVC 5 104 966 CES-A-LSP-05V-104966 10 104 967 CES-A-LSP-10V-104967 15 106 271 CES-A-LSP-15V-106271 20 106 272 CES-A-LSP-20V-106272 25 104 968 CES-A-LSP-25V-104968 SB M5 plug connector - 104 969 CES-A-LSP-SB-104969 Installation material for CES-A-LSP-... For Bosch profiles with 8 mm groove 2 screws and 2 clamping pieces 106 6 Installation material 8-groove Bosch For Bosch profiles with 10 mm groove 2 screws and 2 clamping pieces 106 64 Installation material 10-groove Bosch For ITEM profiles with 8 mm groove 2 screws and 2 clamping pieces 106 65 Installation material 8-groove ITEM With M5 plug con- nector With connection cable Mounting distance CES-A-LSP-... 10 5 20 LED

Upload: others

Post on 03-Feb-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

�2

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

7

97,1

1057

,5Ø 5,2 (2x)

R4

M5

3,3

8,3

5

R3

18,1

ReadheadCES-A-LSP-...

Dimensiondrawing

ReadheadCES-A-LSP-...M5 plug connector, 3-pin or hard-wire encapsulated cable

Active face

OptimizedforaluminumprofilemountingLEDfortheindicationofthedoorposition

Y

1520

2530

5

ZX

5

1520

2530

-20

-25

-30

-45

-50

-55-60

-65

-40

-35

-15

-10

-5

25

30

15

10

45

50

55

60

65

35

5

20

10

40

10

TypicaloperatingdistanceInstalled in aluminum profile 45 x 45 mm

Pinassignment

H11 H12 SH1

BNWH

13

4

ScreenRead headCES-A-LSP

CES-AZ...

For connection cable see page 64

For possible combinations see page 24

Attention:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 42.

Orderingtable

Series Cable/connectiontype/version Cablelength[m]/description Orderno./item

CES-A-LSP-...

VCable PVC

5 104966CES-A-LSP-05V-104966

10 104967CES-A-LSP-10V-104967

15 106271CES-A-LSP-15V-106271

20 106272CES-A-LSP-20V-106272

25 104968CES-A-LSP-25V-104968

SBM5 plug connector - 104969

CES-A-LSP-SB-104969

InstallationmaterialforCES-A-LSP-...

For Bosch profiles with 8 mm groove 2 screws and 2 clamping pieces 1066��Installation material 8-groove Bosch

For Bosch profiles with 10 mm groove 2 screws and 2 clamping pieces 1066�4Installation material 10-groove Bosch

For ITEM profiles with 8 mm groove 2 screws and 2 clamping pieces 1066�5Installation material 8-groove ITEM

With M5 plug con-nector

With connection cable

Mounting distanceCES-A-LSP-...

≤105

≤20

LED

Page 2: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

��

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

TechnicaldatareadheadCES-A-LSP-...

Parameter Value Unit

min. typ. max.

Housing material Reinforced thermoplastic, fully encapsulated

Weight (without connection cable) 0.02 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

Connection type M5 plug connector, 3-pin

LED display White, valid actuator detected

IncombinationwithactuatorCES-A-BSP-104970

Operating distance for center offset m = 0 1)

mm

with vertical approach direction (x direction)

- Assured switch-off distance Sar - - 45

Cable length l = 0 to 25 m

- Switch-on distance - 20 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 1 4 -

Cable length - - 25 m

1) These values apply for the installation of the read head and the actuator in an aluminum profile 45 x 45 mm.

Page 3: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

�4

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

25

42 ±0,

1

52,7

5,4

8

9

4,1

5,3

12

4,5

4,1 19

,4

4,6

32

ReadheadCES-A-LNN-...

Dimensiondrawing

ReadheadCES-A-LNN-...M8 plug connector, 3-pin or hard-wire encapsulated cable

Active face

Cube-shapeddesign42x25mmAttachmentcompatiblewithseriesCES-A-LNA/LCALEDfortheindicationofthedoorposition

Z

-25-30

X

105

1520

-20

-25

-30

-40

-35

-15

-10

-5

-10

20

25

30

15

10

40

35

5

Y

1015

2025

5-5

-15

-20

30

TypicaloperatingdistancePinassignment

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

For connection cable see page 65

For possible combinations see page 24

Attention:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 43.

Orderingtable

Series Cable/connectiontype Cablelength[m] Orderno./item

CES-A-LNN-...

VCable PVC 5 106602

CES-A-LNN-05V-106602

SCM8 plug connector - 106601

CES-A-LNN-SC-106601

With M8 plug connector

With connection cable

Approachdirections

LEDActive face

Active face

For a side approach direction for the actuator and read head, a minimum distance of s = 6 mm must be maintained so that the

operating distance of the side lobes is not entered.

2 safety screws M4x14 are supplied

Page 4: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

�5

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

TechnicaldatareadheadCES-A-LNN-...

Parameter Value Unit

min. typ. max.

Housing material Reinforced thermoplastic (PBT), fully encapsulated

Dimensions 42 x 25 x 12 mm

Weight (without connection cable) 0.025 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

Connection type M8 plug connector, 3-pin or connection cable

LED display White, valid actuator detected

IncombinationwithactuatorCES-A-BBN-106600

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar in x/z direction - - 50

in y direction - - 80

Cable length l = 0 to 25 m

- Switch-on distance - 20 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 1 4 -

IncombinationwithactuatorCES-A-BDN-06-1047�0

Operating distance for center offset m = 0

mm

- Assured switch-off distance Sar in x/z direction - - 80

in y direction - - 50

Cable length l = 0 to 25 m

- Switch-on distance - 19 -

- Assured switch-on distance Sao 14 - -

- Switching hysteresis - 4 -

Cable length - - 25 m

1) These values apply for the surface installation of the read head and the actuator.

Page 5: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

�6

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

ReadheadCES-A-LC.../CES-A-LN...Cube-shapeddesign42x25mm

CES-

A-L

XXXX

XX

25

∅8

∅4,5

42

32±

0,1

12

4,6

"l"

ReadheadCES-A-LNA... (Fortron)Hard-wired encapsulated cable

Active face

Active face

5,5

∅10

6,8

∅8

∅4,5

4,6

12

25

min

.38

32±

0,1

4232

,6

A0

CES-

A-L

0777

15

3 41

ReadheadCES-A-LNA-SC (Fortron)M8 plug, 3-pin

Active face

Active face

Orderingtable

Series Cable/connectiontype Cablelength[m] Type Orderno./item

CES-A-LCA-... VCable PVC 10 Housing material PE-HD 2) 088785

CES-A-LCA-10V

CES-A-LNA-...

VCable PVC

5 071845CES-A-LNA-05V

10 071846CES-A-LNA-10V

15 071847CES-A-LNA-15V

25 071975CES-A-LNA-25V

PCable PUR

5 077806CES-A-LNA-05P

10 077807CES-A-LNA-10P

15 084682CES-A-LNA-15P

SCM8 plug connector - 077715 3)

CES-A-LNA-SC

CES-A-LNA-SC-EX SCM8 plug connector - ATEX 1) 098156 1) 3)

CES-A-LNA-SC-EX

1) EX II 3G Ex nL IIC T70°C (zone 2 gases)2) Suitable for use in aggressive media (e. g. acids, alkalis)3) Plug connector suitable for snap-action and screw terminals

TypicaloperatingdistancePinassignment

32

4248

25

31

l

1214

4,6 ∅8

∅4,5

± 0

,1

Dimensiondrawing

ReadheadCES-A-LCA... (PE-HD)Hard-wired encapsulated cable

Active face

Active face

Seal

X20

1510

5

2015

105

5

10

15

20

Y

Z

For a side approach direction for the actuator and read head, a minimum distance of s = 3 mm must be maintained so that the

operating distance of the side lobes is not entered.

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

For connection cable see page 65

2 safety screws M4x14 are supplied

2 safety screws M4x14 are supplied

2 safety screws M4x14 are supplied

For possible combinations see page 24

Warning:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 45 and 47.

1)

Page 6: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

�7

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Parameter Value Unit

min. typ. max.

Housing material- CES-A-LNA... Fortron, reinforced thermoplastic, fully encapsulated

- CES-A-LCA... Plastic PE-HD without reinforcement, fully encapsulated

Flat seal material (CES-A-LCA... only) Fluororubber 75 FPM 4100

Dimensions 42 x 25 x 12 mm

Weight (incl. 10 m cable) 0.3 kg

Ambient temperature

°C- CES-A-LCA... -25 - +50

- CES-A-LNA.../CES-A-LNA-SC-EX -25 - +70

Degree of protection IP67/IP69K

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

IncombinationwithCES-A-BBA

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar - - 26

Cable length l = 0 to 25 m

- Switch-on distance - 15 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 0.5 2 -

Connection cable- CES-A-LCA.../CES-A-LNA...- CES-A-LNA...

Hard-wired encapsulated connection cable, with crimped ferrulesPVC, ∅ 4.6 mm

PUR, ∅ 4.8 mm, suitable for drag chain

- CES-A-LNA-SC M8 plug connector (snap-action and screw terminals), 3-pin

Cable length See ordering table 25 m1) These values apply for surface installation of the read head and the actuator.

TechnicaldatareadheadCES-A-LC.../CES-A-LN...

Page 7: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

�8

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

40 ±0,15

50 0,250

M8

40±

0,15

500,

250

20

7

6

20,2

Ø4,

5

-

x1

-

ReadheadCES-A-LQA-SC

Dimensiondrawing

ReadheadCES-A-LQA-SCM8 plug, 3-pin

Active face

Cube-shapeddesign50x50mmM8plugconnector(snap-actionandscrewterminals)

Orderingtable

Series Connectiontype Comment Orderno./item

CES-A-LQA-SC SCM8 plug connector 2 safety screws M4 x 14 are supplied 095650

CES-A-LQA-SC

TypicaloperatingdistancePinassignment

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

For connection cable see page 65

For possible combinations see page 24

Warning:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 46.

1020

30

Y

10

20

30

20

10

X 30Z

10

-30

2030

Z

Y

10

20

30

-30

30

20

10

X

With actuator CES-A-BBA or CES-A-BCA With actuator CES-A-BQA and evaluation unit CES-AZ-...-01B

Page 8: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

�9

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

TechnicaldatareadheadCES-A-LQA-SC

Parameter Value Unit

min. typ. max.

Housing material Fortron, reinforced thermoplastic, fully encapsulated

Dimensions 50 x 50 x 20.2 mm

Weight 0.08 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

IncombinationwithactuatorCES-A-BBAorCES-A-BCA

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar - - 47

Cable length l = 0 to 25 m

- Switch-on distance - 15 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 2 3 -

IncombinationwithactuatorCES-A-BQAandevaluationunitCES-AZ-...-01B

Operating distance for center offset m = 0 1)

mm

Cable length l = 0 to 25 m

- Assured switch-off distance Sar - - 60

For vertical approach direction

- Switch-on distance - 23 -

- Assured switch-on distance Sao 16 - -

- Switching hysteresis 2 3 -

For side approach direction

- Switch-on distance - 28 -

- Assured switch-on distance Sao 24 - -

- Switching hysteresis 1 1.3 -

Cable length - - 25 m

1) These values apply for surface installation of the read head and the actuator.

Page 9: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

40

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

17

5

32 19,7

Read distance s

Cent

er o

ffset

m

connected 35

4

830

M12

x1

M8x

1

37

1)

1)

ReadheadCES-A-LMN-SC

Dimensiondrawing

ReadheadCES-A-LMN-SCM8 plug, 3-pin

Active face

CylindricaldesignM12M8plugconnector(snap-actionandscrewterminals)

Orderingtable

Series Connectiontype Type Orderno./item

CES-A-LMN-SC SCM8 plug connector Housing M12 077790

CES-A-LMN-SC

CES-A-LMN-SC-EX SCM8 plug connector ATEX 1) 098157 1)

CES-A-LMN-SC-EX

1) EX II 3G Ex nL IIC T70°C (zone 2 gases)

TypicaloperatingdistancePinassignment

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

1) Clear zone (area of the active face without metal housing)

For connection cable see page 65

For possible combinations see page 24

Warning:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 48.

A minimum distance of s = 1.2 mm must be maintained.

2

4

6

6

8

8

X8

64

22

46

8

86

Y

Z

1)

Page 10: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

41

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Parameter Value Unit

min. typ. max.

Housing material Nickel-plated CuZn housing sleevePlastic PBT GF20 cap

Dimensions M12 x 1, length 38 mm

Weight 0.2 kg

Ambient temperature

°C- CES-A-LMN-SC -20 - +70

- CES-A-LMN-SC-EX -20 - +60

Ambient pressure(only of active face in installed condition) - - 10 bar

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

IncombinationwithactuatorCES-A-BMB

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar - - 10

Cable length l = 0 to 15 m

- Switch-on distance - 5 -

- Assured switch-on distance Sao 3.5 - -

- Switching hysteresis 0.1 0.3 -

Connection M8 plug connector (snap-action and screw terminals), 3-pin

Cable length - - 15 m1) These values apply for surface installation of the read head in steel.

TechnicaldatareadheadCES-A-LMN-SC

Page 11: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

42

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

97,1

1057

,5

Ø 5,218,1

65

R2

ActuatorCES-A-BSP

Dimensiondrawing

ActuatorCES-A-BSP

Active face

Optimizedforaluminumprofilemounting

Orderingtable

Series Comment Version Orderno./item

CES-A-BSP Please order installation material separately

104970CES-A-BSP-104970

InstallationmaterialforCES-A-BSP

For Bosch profiles with 8 mm groove 2 screws and 2 clamping pieces 1066��Installation material 8-groove Bosch

For Bosch profiles with 10 mm groove 2 screws and 2 clamping pieces 1066�4Installation material 10-groove Bosch

For ITEM profiles with 8mm groove 2 screws and 2 clamping pieces 1066�5Installation material 8-groove ITEM

Technicaldata

ParameterValue

Unitmin. typ. max.

Housing material Reinforced thermoplastic, fully encapsulated

Weight 0.02 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Active face opposite read head

Power supply Inductive via read head

For possible combinations see page 24

Page 12: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

4�

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

25

42 ±0,

1

8

12

4,5

32

ActuatorCES-A-BBN

Dimensiondrawing

ActuatorCES-A-BBN

Active face

Cube-shapeddesign42x25mmAttachmentcompatiblewithactuatorCES-A-BBA/BCA

Orderingtable

Series Comment Version Orderno./item

CES-A-BBN 2 safety screws M4 x 14 are supplied 106600CES-A-BBN-106600

Technicaldata

ParameterValue

Unitmin. typ. max.

Housing material Reinforced thermoplastic (PBT), fully encapsulated

Dimensions 42 x 45 x 12 mm

Weight 0.025 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Active face opposite read head

Power supply Inductive via read head

2 safety screws M4x14 are supplied

For possible combinations see page 24 Active face

Page 13: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

44

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

26 0+0,5

Ø30

* m

in.

30 *30 *

6,1 0+0,1

z

y

x

6

ActuatorCES-A-BDN-06

Dimensiondrawing

ActuatorCES-A-BDN-06

Installation options

Cylindricaldesign∅6mm

Orderingtable

Series Comment Version Orderno./item

CES-A-BDN-06 1047�0CES-A-BDN-06-104730

Technicaldata

ParameterValue

Unitmin. typ. max.

Housing material Macromelt PA-based plastic

Dimensions 26 x ∅ 6 mm

Weight 0.005 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Active face opposite read head

Power supply Inductive via read head

For possible combinations see page 24

* metal-free zone

Page 14: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

45

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES-A-B 071840

25

ø8ø4,5

42

32 ±0,1

12

4,6

ActuatorCES-A-BBA/CES-A-BCA

Dimensiondrawing

ActuatorCES-A-BBA (Fortron)

Active face

Cube-shapeddesign42x25mm

Active face

42

32± 0,10

25 31

48

∅4,

5

∅8

2 12

4,6

ActuatorCES-A-BCA (PE-HD)Housing material PE-HD

Active faceSeal

Orderingtable

Series Comment Type Orderno./item

CES-A-BBA 2 safety screws M4 x 14 are supplied - 071840CES-A-BBA

CES-A-BBA-EX 2 safety screws M4 x 14 are supplied ATEX 1) 098158 1)

CES-A-BBA-EX

CES-A-BCA 2 safety screws M4 x 14 are suppliedFlat seal included Housing material PE-HD 2) 088786

CES-A-BCA1) EX II 3G Ex nL IIC T70°C (zone 2 gases) and EX II 3D Ex tD A22 T70°C2) Suitable for use in aggressive media (e. g. acids, alkalis)

2 safety screws M4x14 are supplied

2 safety screws M4x14 are supplied

Technicaldata

ParameterValue

Unitmin. typ. max.

Housing material- CES-A-BBA Fortron, reinforced thermoplastic, fully encapsulated

- CES-A-BCA Plastic PE-HD without reinforcement, fully encapsulated

Flat seal material (CES-A-BCA only) Fluororubber 75 FPM 4100

Dimensions 42 x 25 x 12 mm

Weight 0.02 kg

Ambient temperature- CES-A-BBA -25 - +70

°C- CES-A-BBA-EX -25 - +60

- CES-A-BCA -25 - +50

Degree of protection IP67/IP69K

Installation position Active face opposite read head

Power supply Inductive via read head

For possible combinations see page 24

1)

Page 15: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

46

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

40 ±0,15

50 0,250

40±

0,15

500,

250

6

20,2

Ø4,

5

-

-

ActuatorCES-A-BQA

Dimensiondrawing

ActuatorCES-A-BQA

Active face

Cube-shapeddesign50x50mm

Orderingtable

Series Comment Type Orderno./item

CES-A-BQA 2 safety screws M4 x 14 are supplied 098108CES-A-BQA

Technicaldata

ParameterValue

Unitmin. typ. max.

Housing material Fortron, reinforced thermoplastic, fully encapsulated

Dimensions 50 x 50 x 20.2 mm

Weight 0.07 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Active face opposite read head

Power supply Inductive via read head

2 safety screws M4x14 are supplied

For possible combinations see page 24

Page 16: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

47

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

∅ 20 2,2

ActuatorCES-A-BDA

Dimensiondrawing

ActuatorCES-A-BDA

Active face

Rounddesign∅20mm

Active face

Orderingtable

Series Comment Type Orderno./item

CES-A-BDA 084720CES-A-BDA-20

Technicaldata

ParameterValue

Unitmin. typ. max.

Housing material Plastic PC

Dimensions ∅ 20 x 2.2 mm

Weight 0.0008 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Active face opposite read head

Power supply Inductive via read head

For possible combinations see page 24

Page 17: Non-Contact Safety System CES-AZNon-Contact Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 25 42 ±0,1

48

Non-Contact Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

11

0,80

6

M12

x0,7

5

ActuatorCES-A-BMB/CES-A-BMB-EX

Dimensiondrawing

ActuatorCES-A-BMB

Active face

CylindricaldesignM12x0.75

Orderingtable

Series Comment Type Orderno./item

CES-A-BMB 077791CES-A-BMB

CES-A-BMB-EX ATEX 1) 098159 1)

CES-A-BMB-EXInsertiontool For actuator CES-A-BMB 0�7662

1) EX II 3G Ex nL IIC T70°C (zone 2 gases)

Technicaldata

ParameterValue

Unitmin. typ. max.

Housing material Stainless steel, Niro

Dimensions M12 x 0.75, depth 6 mm

Weight 0.002 kg

Ambient temperature -25 - +70 °C

Ambient pressure (only applies if the pressure acts on all sides of the actuator) - - 10 bar

Degree of protection IP67

Installation position Active face opposite read head

Power supply Inductive via read head

InsertiontoolWith the aid of the insertion tool, the actuator CES-A-BMB (cylindrical design) can be screwed into a prepared M12 x 0.75 thread in safety doors.

12,3 +0,12-0,06

11,1 +0,12-0,06

15

1,5

t = 0,6

Insertion toolFor possible combinations see page 24

1)