NYC Department of Education Building Condition Assessment Survey 2018-2019 M061 Architectural Inspection Inspection Type Last Edited Time In InspectionId P.S. 61 - MANHATTAN, 610 EAST 12 STREET, MANHATTAN, NY, 10009 School: 1111 2019-01-03 09:16AM 2019-01-22 12:27PM ARCHITECTURAL - ASSOCIATE 1194 2019-01-03 09:25AM 2019-06-27 05:19PM ARCHITECTURAL - SENIOR Asset Data Question Answer Was the Building Fully Accessible for Inspection? Yes Principal(s) Information Principal Name Bradley Goodman Principal Organization PS 315- Manhattan Meeting with Principal? No Principal Feedback No Feedback from Principal Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback The principal provided the following comments: 1) The heating system controls need to be corrected, or replaced. 2) The corridor radiator needs to be the covered as it is open and can cause a hazardous condition. 3) Radiator covers in corridors are loose and need to be properly attached to the walls, 4) Stair wall ceramic tile is loose and broken and needs to be repaired, 5) Very old wiring which are no longer in use must be removed, 6) Cafeteria Student Toilets are deteriorated and need to be renovated. Principal Name Jeanne Bradley Principal Organization M094 SPED - Manhattan Meeting with Principal? No Principal Feedback No Feedback from Principal Custodian Alejandro Deno Fireman Paul Delusme Building Square Footage 75,000 Comments on the Area (Square Feet) None Comments on the Stories (Floors) plus Basements 5 + B + PH Comments on the Year Built 1913 Comments on the Student Population 680 Comments on the Staff Population 175 Comments on the Number of Classrooms 46 Weather Fair Facade Photo East 12th Street - South view Page 1 of 32 Print Date: 7/3/2019 Mobile Validity Version 2.0 (P)

Upload: others

Post on 19-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Inspection Type Last EditedTime InInspectionId

P.S. 61 - MANHATTAN, 610 EAST 12 STREET, MANHATTAN, NY, 10009School:

1111 2019-01-03 09:16AM 2019-01-22 12:27PMARCHITECTURAL - ASSOCIATE

1194 2019-01-03 09:25AM 2019-06-27 05:19PMARCHITECTURAL - SENIOR

Asset DataQuestion Answer

Was the Building Fully Accessible for Inspection? Yes

Principal(s) Information

Principal Name Bradley Goodman

Principal Organization PS 315- Manhattan

Meeting with Principal? No

Principal Feedback No Feedback from Principal

Principal Name Maria Velez Clare

Principal Organization P.S. 361-Manhattan

Meeting with Principal? Yes

Principal Feedback The principal provided the following comments: 1) The heating

system controls need to be corrected, or replaced. 2) The corridor

radiator needs to be the covered as it is open and can cause a

hazardous condition. 3) Radiator covers in corridors are loose and

need to be properly attached to the walls, 4) Stair wall ceramic

tile is loose and broken and needs to be repaired, 5) Very old

wiring which are no longer in use must be removed, 6) Cafeteria

Student Toilets are deteriorated and need to be renovated.

Principal Name Jeanne Bradley

Principal Organization M094 SPED - Manhattan

Meeting with Principal? No

Principal Feedback No Feedback from Principal

Custodian Alejandro Deno

Fireman Paul Delusme

Building Square Footage 75,000

Comments on the Area (Square Feet) None

Comments on the Stories (Floors) plus Basements 5 + B + PH

Comments on the Year Built 1913

Comments on the Student Population 680

Comments on the Staff Population 175

Comments on the Number of Classrooms 46

Weather Fair

Facade Photo

East 12th Street - South view

Page 1 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 2: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural InspectionMain Entrance Photo

Facade A - East 12th Street

Roof Photo

Roof 1 - Northeast view

Have any Systems/Major Building Components been upgraded? Systems: Split mechanical system was added

Years: 2018

Systems: New DOT Concrete Sidewalk along East 12th Street

eliminated Ash Hoist Doors and frames. Sealed Vault.

Years: 2018

Systems: New Boys and Girls Toilets on 3rd Floor

Years: 2017

Systems: Complete Flashing, Coping, Plaza Decking, Windows

and Guards Replacement, Limited Exterior Doors

replacement, Masonry replacement at all Facades

except East 12th Street facade, Parapet replacement,

Chimney reconstruction .

Years: 2014

Systems: Limited Exterior Door replacement

Years: 2011

Systems: Partial Exterior Masonry repairs

Years: 2007

Systems: Complete Roofing and Plaza Decking replacement,

Limited Exterior Masonry and Bulkhead repairs.

Years: 2002

Have there been any New Building Additions? No New Construction

Tandem No Tandem

Leased Space? No

Priority Condition

Page 2 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 3: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural InspectionExist

Last Year?

Priority

Category

Condition

Description

Component

Affected

Location

Description

Person(s)

Notified

Person(s)

Title

Photo

Image

Potential Falling

DebrisA severely corroded

section of loose metal

form may fall to the

Basement Floor causing a

hazardous condition.

Floor

Structure

Basement -

Boiler Room

(Shown); also

Storage

Room, and

other

Basement

locations

similar.

Paul

Delusme

No Fireman

Structural Engineer Required

Structural

Condition Type

Condition

Description

Component

Affected

Location

Description

Person(s)

Notified

Person(s)

Title

Photo

Image

Deteriorated Steel Columns / Beams /

Bearing Walls

Columns / Beams /

Bearing Walls

Basement -

Entrance to Vault at

North Wall

Fireman Fireman

Accessibility

Accessibility Status Question Response

Physical Breakdown Structure Exists Complies Required Deficiency

FUNCTIONAL ACCESSIBILITY

Exterior Routes

YesExterior Entrances & Exits

NoNoExterior H/C Lifts

NoNoExterior Ramps and Railings

Interior Routes

NoNoCorridor and Lobby H/C Lifts

NoYesInterior Corridor Doors And Hardware

YesInterior Corridors & Lobbies

YesYesInterior Elevators

YesInterior Lobby Doors And Hardware

NoInterior Ramps

Rooms & Spaces

Art Rooms

Yes YesRooms 305 and 413

Auditorium

Yes No1st Floor

NOT ON ACCESSIBLE ROUTE

Cafeteria

Yes Yes1st Floor

Classrooms

Yes NoNone on Accessible Route

NOT ON ACCESSIBLE ROUTE

NoComputer Rooms

NoGymnasium

Library

Yes YesRoom 408

Main Office

Page 3 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 4: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Physical Breakdown Structure Exists Complies Required Deficiency

Yes NoRooms 209, 409 and 509

NOT ON ACCESSIBLE ROUTE

Multi-purpose Room

Yes No1st Floor

NOT ON ACCESSIBLE ROUTE

Nurse's Office

Yes NoRoom 213 and 552

NOT ON ACCESSIBLE ROUTE

NoPool

NoScience Lab

Toilet Rooms (boys)

Yes NoNone on Accessible Route

NOT ON ACCESSIBLE ROUTE

Toilet Rooms (girls)

Yes NoNone on Accessible Route

NOT ON ACCESSIBLE ROUTE

Toilet Rooms (staff)

Yes NoNone on Accessible Route

NOT ON ACCESSIBLE ROUTE

Building Template

Inspection

Question Response

Architectural

ATHLETIC FIELDS Does not exist

EXTERIOR Inspected

InspectedAREAWAY

Instance on AW1-AW3 Inspected

3- FairInstance Condition

Instance Quantity 3

Instance Quantity Uom EACH

AREAWAY DRAINS:CLOGGEDDeficiency

Page 4 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 5: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

AREAWAY

Deficiency Location/Instance

1Deficiency Quantity

Quantity Uom EACH

Potential Action MAINTENANCE

PRIORITY 5Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Plaza Deck East

Violations No violations recorded

Does not existAWNINGS AND CANOPIES

InspectedCHIMNEY

MasonryMaterial Type(s)

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedCOPING

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedCORNICE

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedDOORS

InspectedDOOR HARDWARE

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedDOORS AND FRAMES

Condition 4- Between Fair and Poor

METAL:DETERIORATED DOOR AND FRAME - MINOR

DETERIORATION

Deficiency

Deficiency Location/Instance

3Deficiency Quantity

Quantity Uom EACH

Potential Action MAINTENANCE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 5 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 6: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

DOORS

DOORS AND FRAMES

Deficiency Photo 1

Front Entrance

Violations No violations recorded

InspectedLINTELS

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedTRANSOM/SIDE LIGHT

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

Does not existEXTERIOR SOFFITS

InspectedEXTERIOR WALLS

MasonryMaterial Type(s)

40,000Replacement Quantity

Replacement Uom S.F.

Instance on All Facades Inspected

3- FairInstance Condition

Instance Quantity 40,000

Instance Quantity Uom S.F.

BRICK:EFFLORESCENCEDeficiency

Roof Plan Reference

Elevation

Elevation Reference Elevation B

600Deficiency Quantity

Quantity Uom S.F.

Potential Action MAINTENANCE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 6 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 7: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

EXTERIOR WALLS

Deficiency Photo 1

Elevation B

Violations No violations recorded

BRICK:CRACKS/DISPLACED/SPALLED BRICK AT

BUILDING CORNERS

Deficiency

Roof Plan Reference

Elevation

Elevation Reference Elevation C

40Deficiency Quantity

Quantity Uom S.F.

Potential Action REMOVE AND REBUILD

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Long Elevation C

Violations No violations recorded

Does not existLOADING DOCK

InspectedLOUVER

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedPARAPETS

MasonryMaterial Type(s)

3,000Replacement Quantity

Replacement Uom C.F.

Instance on All Facades Inspected

2- Between Good and FairInstance Condition

Instance Quantity 3,000

Instance Quantity Uom CF

Page 7 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 8: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

PARAPETS

No deficiencies recordedDeficiency

InspectedPLAZA DECK

Instance on Pavers:Roof 2 and 3 Inspected

3- FairInstance Condition

Instance Quantity 4,000

Instance Quantity Uom S.F.

Installation Year 2014

Source of Installation Year Documented

PAVERS:MINOR LEAKAGEDeficiency

Deficiency Location/Instance

40Deficiency Quantity

Quantity Uom S.F.

Potential Action REPAIR

PRIORITY 5Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Work underway to make corrections on Roof 3

Violations No violations recorded

PAVERS:PAVERS IN POOR CONDITIONDeficiency

Deficiency Location/Instance

500Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Plaza Deck East (Roof 3)

Violations No violations recorded

Page 8 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 9: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

InspectedROOF

InspectedROOFING

Replacement Quantity 10,000

Replacement Uom S.F.

InspectedLEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS

2- Between Good and FairCondition

No deficiencies recordedDeficiency

InspectedROOF BARRIER

2- Between Good and FairCondition

No deficiencies recordedDeficiency

Does not existROOF CAGE

InspectedROOF FENCE

2- Between Good and FairCondition

No deficiencies recordedDeficiency

InspectedROOF HATCH/SMOKE HATCH

2- Between Good and FairCondition

No deficiencies recordedDeficiency

InspectedROOFING

Instance on Built-Up:Roof 1 Inspected

2- Between Good and FairInstance Condition

Instance Quantity 10,000

Instance Quantity Uom S.F.

“Does the roof have major mechanical equipment sitting on Dunnage

Steel less than 18" above the Roofing?"

No

Installation Year 2014

Source of Installation Year Documented

BUILT-UP:ROOFING:MINOR LEAKAGEDeficiency

Deficiency Location/Instance

30Deficiency Quantity

Quantity Uom S.F.

Potential Action REPAIR

PRIORITY 5Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Room 207

Violations No violations recorded

InspectedROOFING DRAINS

2- Between Good and FairCondition

No deficiencies recordedDeficiency

InspectedSPECIALTIES

InspectedBULKHEAD/PENTHOUSE

Page 9 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 10: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

ROOF

SPECIALTIES

BULKHEAD/PENTHOUSE

4- Between Fair and PoorCondition

BULKHEAD/PENTHOUSE WALLS/INTERIOR:GYPSUM

BOARD DAMAGED/DETERIORATED

Deficiency

Deficiency Location/Instance

35Deficiency Quantity

Quantity Uom S.F.

Potential Action MAINTENANCE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Inside Bulkhead

Violations No violations recorded

BULKHEAD/PENTHOUSE WALLS/EXTERIOR:DAMAGED

METAL SIDING

Deficiency

Deficiency Location/Instance

50Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Bulkhead 1

Violations No violations recorded

Does not existCUPOLA/ SPIRES/ TOWERS

Does not existDORMER

Does not existDUNNAGE STEEL

Page 10 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 11: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

ROOF

SPECIALTIES

InspectedROOF/GRAVITY TANK

3- FairCondition

STEEL STRUCTURE:NOT IN USE - MAJOR

DETERIORATION

Deficiency

Deficiency Location/Instance

1Deficiency Quantity

Quantity Uom EACH

Potential Action REMOVE

PRIORITY 1Urgency of Action

LEVEL 1Purpose of Action

Violations No violations recorded

InspectedSKYLIGHT/ROOF VENT

Material Type(s) Glass

3- FairCondition

BROKEN GLASSDeficiency

Deficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action MAINTENANCE

PRIORITY 5Urgency of Action

LEVEL 2Purpose of Action

Violations No violations recorded

InspectedSTAIRS/RAMPS: EXTERIOR

InspectedBUILDING CHEEK/FLANK WALLS

Condition 3- Fair

CAST IN PLACE CONCRETE:CRACKS/SPALLING - MINORDeficiency

Deficiency Location/Instance

18Deficiency Quantity

Quantity Uom S.F.

Potential Action REPAIR

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 11 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 12: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

STAIRS/RAMPS: EXTERIOR

BUILDING CHEEK/FLANK WALLS

Deficiency Photo 1

Main Front Entrance

Violations No violations recorded

InspectedRAILINGS

Condition 4- Between Fair and Poor

DAMAGEDDeficiency

Deficiency Location/Instance

12Deficiency Quantity

Quantity Uom L.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Railing at Ramp

Violations No violations recorded

MISSING RAILINGDeficiency

Deficiency Location/Instance

10Deficiency Quantity

Quantity Uom L.F.

Potential Action REPLACE

PRIORITY 5Urgency of Action

LEVEL 6Purpose of Action

Page 12 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 13: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

STAIRS/RAMPS: EXTERIOR

RAILINGS

Deficiency Photo 1

Facade A - Main Entrance Steps

Violations 35321669R

InspectedSTAIRS/RAMPS

Condition 4- Between Fair and Poor

CONCRETE:WORN-OUT TREAD/RISER/NOSINGDeficiency

Deficiency Location/Instance

30Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Building Front

Violations No violations recorded

InspectedWINDOWS

12,000Replacement Quantity

Replacement Uom S.F.

InspectedEXTERIOR GUARDS

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedLINTELS

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedWINDOWS

Material Type(s) Aluminum

Instance on Aluminum - Double Hung:All Facades Inspected

2- Between Good and FairInstance Condition

Instance Quantity 12,000

Instance Quantity Uom S.F.

Installation Year 2014

Source of Installation Year Documented

Page 13 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 14: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

EXTERIOR

WINDOWS

WINDOWS

No deficiencies recordedDeficiency

INTERIOR Inspected

AUDITORIUM

Instance on 1st Floor Inspected

Ceiling

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Door(s)

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Fixed H/C Lift

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Fixed Seating

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Floor Finish

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Sliding-folding Partition

Instance on 1st Floor Does not exist

Stage

Instance on 1st Floor Inspected

Stage

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Stage Curtain Rigging

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Stage Curtains

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Walls

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

PLASTER:CRACKS/SPALLINGDeficiency

Near Vestibule, Near Stage, at South of RoomDeficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 14 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 15: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

AUDITORIUM

Walls

Deficiency Photo 1

Near Vestibule

Violations No violations recorded

MASONRY:CRACKS/SPALLING - ACTIVE LEAKDeficiency

Exit Vestibule near Stage AreaDeficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 5Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Exit Vestibule near Stage Area

Violations No violations recorded

Window Curtains/Shades/Blinds

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

CAFETERIA

Instance on 1st Floor Inspected

Ceiling

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Door(s)

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Fixed Equipment

Instance on 1st Floor Does not exist

Floor Finish

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

VINYL TILES:BROKEN/DETERIORATED/MISSING TILESDeficiency

CenterDeficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

Page 15 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 16: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

CAFETERIA

Floor Finish

LEVEL 2Purpose of Action

Deficiency Photo 1

Center

Violations No violations recorded

Sliding-folding Partition

Instance on 1st Floor Does not exist

Stage

Instance on 1st Floor Does not exist

Walls

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

PLASTER:CRACKS/SPALLINGDeficiency

Exit to SchoolyardDeficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Exit to Schoolyard

Violations No violations recorded

Window Curtains/Shades/Blinds

Instance on 1st Floor Does not exist

InspectedCLASSROOMS/CORRIDORS/ADMIN SPACES

InspectedCeiling

Condition 2- Between Good and Fair

PLASTER:CRACKS/SPALLINGDeficiency

Vestibule Near AuditoriumDeficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 16 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 17: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

CLASSROOMS/CORRIDORS/ADMIN SPACES

Ceiling

Deficiency Photo 1

Vestibule Near Auditorium

Violations No violations recorded

InspectedDoor(s)

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedFloor Finish

Condition 2- Between Good and Fair

VINYL TILES:BROKEN/DETERIORATED/MISSING TILESDeficiency

Rooms 205, 207, 209, At Corridor near Stair A/2, CB/5, G/2, 5,

Near Rooms 412, 501, 506B, and 557

Deficiency Location/Instance

400Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

At Corridor near Stair CB/5

Violations No violations recorded

Does not existSpecialties

InspectedWalls

Condition 2- Between Good and Fair

PLASTER:CRACKS/SPALLINGDeficiency

Room 212Deficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Room 212

Violations No violations recorded

Page 17 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 18: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

CLASSROOMS/CORRIDORS/ADMIN SPACES

Walls

PLASTER:CRACKS/SPALLING - ACTIVE LEAKDeficiency

Room 207, At Corridor near Room 207Deficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 5Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Room 207

Deficiency Photo 2

At Corridor near Room 207

Violations No violations recorded

Does not existGYMNASIUM

InspectedINTERIOR DOOR HARDWARE

Condition 3- Fair

No deficiencies recordedDeficiency

InspectedINTERIOR GUARDS

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

KITCHEN

Instance on 1st Floor Inspected

Ceiling

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Door(s)

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Floor Finish

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Walls

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

LIBRARY

Page 18 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 19: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

LIBRARY

Instance on Room 408 Inspected

Built-in Furnishing

Instance on Room 408 Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Ceiling

Instance on Room 408 Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Door(s)

Instance on Room 408 Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Floor Finish

Instance on Room 408 Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Walls

Instance on Room 408 Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Does not existLOCKER ROOM

MULTI-PURPOSE ROOM

Instance on 1st Floor Inspected

Ceiling

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

No deficiencies recordedDeficiency

Door(s)

Instance on 1st Floor Not required

Fixed Equipment

Instance on 1st Floor Does not exist

Floor Finish

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

VINYL TILES:BROKEN/DETERIORATED/MISSING TILESDeficiency

Near custodian’s officeDeficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Near custodian’s office

Violations No violations recorded

Page 19 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 20: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

MULTI-PURPOSE ROOM

Sliding-folding Partition

Instance on 1st Floor Does not exist

Stage

Instance on 1st Floor Does not exist

Walls

Instance on 1st Floor Inspected

2- Between Good and FairInstance Condition

PLASTER:CRACKS/SPALLINGDeficiency

Near Custodian’s OfficeDeficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Near Custodian’s Office

Violations No violations recorded

Window Curtains/Shades/Blinds

Instance on 1st Floor Does not exist

Does not existPOOLS

Does not existSCIENCE DEMO ROOM

Does not existSCIENCE LAB

Does not existSCIENCE PREP ROOM

Does not existSHOWER ROOM

InspectedSTAIRS/RAMPS: INTERIOR

Do Letter Stair Signs Exist? 1

InspectedCeiling

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedDoor(s)

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedPartition

Condition 2- Between Good and Fair

GLASS PANEL:DAMAGED/DETERIORATEDDeficiency

Stairs BC/2, 4, F/1, and 3Deficiency Location/Instance

40Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 20 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 21: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

STAIRS/RAMPS: INTERIOR

Partition

Deficiency Photo 1

Stair F/1

Violations No violations recorded

InspectedRailings

Condition 5- Poor

METAL:MISSINGDeficiency

Stair D/2, and 3Deficiency Location/Instance

30Deficiency Quantity

Quantity Uom L.F.

Potential Action REPLACE

PRIORITY 5Urgency of Action

LEVEL 6Purpose of Action

Deficiency Photo 1

Stair D/3

Violations No violations recorded

METAL:BROKEN BRACKETDeficiency

Stair G/4Deficiency Location/Instance

1Deficiency Quantity

Quantity Uom EACH

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Stair G/4

Violations No violations recorded

InspectedStairs and Landings

Condition 3- Fair

STONE:BROKEN/MISSINGDeficiency

Main Entrance Vestibule, Vestibule to CafeteriaDeficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Page 21 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 22: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

STAIRS/RAMPS: INTERIOR

Stairs and Landings

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Main Entrance Vestibule

Violations No violations recorded

ROLLED ASPHALT:CRACKSDeficiency

Stairs B/Bulkhead, D/Bulkhead, E/Bulkhead, F/1Deficiency Location/Instance

200Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Stair F/1

Deficiency Photo 2

Stair E/Bulkhead

Violations No violations recorded

InspectedWalls

Condition 2- Between Good and Fair

CERAMIC TILE:BROKEN/ MISSINGDeficiency

Stair C/1, G/2, 5, F/1, 2 and other locationsDeficiency Location/Instance

50Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 22 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 23: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

STAIRS/RAMPS: INTERIOR

Walls

Deficiency Photo 1

Stair F/1

Violations No violations recorded

InspectedSTRUCTURAL

InspectedCOLUMNS/BEAMS/BEARING WALLS

Condition 4- Between Fair and Poor

MASONRY BEARING WALL:OPEN JOINTSDeficiency

Boiler RoomDeficiency Location/Instance

200Deficiency Quantity

Quantity Uom S.F.

Potential Action REPOINT

PRIORITY 3Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Storage Room

Deficiency Photo 2

Wall near Storage Area

Violations No violations recorded

STEEL COLUMNS/BEAMS:DETERIORATED CONCRETE

FIREPROOFING

Deficiency

Throughout BasementDeficiency Location/Instance

30Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 4Urgency of Action

LEVEL 5Purpose of Action

Page 23 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 24: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

STRUCTURAL

COLUMNS/BEAMS/BEARING WALLS

Deficiency Photo 1

Boiler Room Area

Violations No violations recorded

STEEL COLUMNS/BEAMS:MAJOR RUSTINGDeficiency

BasementDeficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 5Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Entrance to Vault - North Wall

Violations No violations recorded

InspectedFLOOR STRUCTURE

Condition 4- Between Fair and Poor

CONCRETE SLAB ON GRADE:MINOR CRACKSDeficiency

Throughout Boiler Room and Adjacent SpacesDeficiency Location/Instance

150Deficiency Quantity

Quantity Uom S.F.

Potential Action REPAIR

PRIORITY 3Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Boiler Room

Violations No violations recorded

CINDER CONCRETE ARCH:METAL PAN DETERIORATED,

SPALLED

Deficiency

BasementDeficiency Location/Instance

300Deficiency Quantity

Quantity Uom S.F.

Potential Action REPAIR

PRIORITY 5Urgency of Action

Page 24 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 25: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

STRUCTURAL

FLOOR STRUCTURE

LEVEL 6Purpose of Action

Deficiency Photo 1

Boiler Room

Violations No violations recorded

InspectedFOUNDATION WALLS

Material Type(s) Masonry

Condition 4- Between Fair and Poor

BRICK:CRACKED/SPALLEDDeficiency

BasementDeficiency Location/Instance

250Deficiency Quantity

Quantity Uom S.F.

Potential Action RESTITCH

PRIORITY 3Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Boiler Room

Violations No violations recorded

BRICK:WATER INFILTRATION IN ELECTRICAL PANEL

ROOM

Deficiency

BasementDeficiency Location/Instance

100Deficiency Quantity

Quantity Uom S.F.

Potential Action INSTALL WATERPROOFING

PRIORITY 5Urgency of Action

LEVEL 6Purpose of Action

Deficiency Photo 1

Electric Meter Room

Violations No violations recorded

InspectedROOF STRUCTURE

Condition 4- Between Fair and Poor

METAL DECK AND CONCRETE:DETERIORATEDDeficiency

Page 25 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 26: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

STRUCTURAL

ROOF STRUCTURE

Boiler Room and Adjacent AreaDeficiency Location/Instance

200Deficiency Quantity

Quantity Uom S.F.

Potential Action REPAIR

PRIORITY 4Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Boiler a Room Area

Violations No violations recorded

InspectedVAULTS-BUNKERS

InspectedFoundation Walls

4- Between Fair and PoorCondition

OPEN JOINTSDeficiency

Space Off the Boiler RoomDeficiency Location/Instance

60Deficiency Quantity

Quantity Uom S.F.

Potential Action REPOINT

PRIORITY 3Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Alcove off the the Boiler Room

Violations No violations recorded

InspectedSlab Structure

4- Between Fair and PoorCondition

CONCRETE SLAB ON GRADE:THRU CRACKSDeficiency

Vault RoomDeficiency Location/Instance

20Deficiency Quantity

Quantity Uom S.F.

Potential Action REPAIR

PRIORITY 4Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Page 26 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 27: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

STRUCTURAL

VAULTS-BUNKERS

Slab Structure

Vault Slab

Violations No violations recorded

CONCRETE SLAB ON GRADE:WATER INFILTRATION IN

NON- INSTRUCTIONAL SPACE

Deficiency

BasementDeficiency Location/Instance

30Deficiency Quantity

Quantity Uom S.F.

Potential Action INSTALL WATERPROOFING

PRIORITY 5Urgency of Action

LEVEL 5Purpose of Action

Deficiency Photo 1

Vault Slab - North Wall

Violations No violations recorded

InspectedVault/Ash Hoist Doors and Framing

3- FairCondition

MINOR RUSTINGDeficiency

East 12th StreetDeficiency Location/Instance

2Deficiency Quantity

Quantity Uom EACH

Potential Action REPAIR

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Violations No violations recorded

InspectedTOILET ROOMS - STAFF

InspectedCeiling

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedDoor(s)

Condition 3- Fair

WOOD:DAMAGED LOUVERDeficiency

Near Room 412Deficiency Location/Instance

1Deficiency Quantity

Quantity Uom EACH

Potential Action MAINTENANCE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Page 27 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 28: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

TOILET ROOMS - STAFF

Door(s)

Near Room 412

Violations No violations recorded

InspectedFloor Finish

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

Does not existStalls

InspectedWalls

Condition 2- Between Good and Fair

CERAMIC TILE:BROKEN/ MISSINGDeficiency

Near Room 212Deficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Near Room 212

Violations No violations recorded

PLASTER:CRACKS/SPALLINGDeficiency

Near Room 212Deficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Near Room 212

Violations No violations recorded

InspectedTOILET ROOMS - STUDENTS

InspectedCeiling

Condition 2- Between Good and Fair

PLASTER:CRACKS/SPALLINGDeficiency

Near Stair G/3Deficiency Location/Instance

15Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Page 28 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 29: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

TOILET ROOMS - STUDENTS

Ceiling

Deficiency Photo 1

Near Stair G/3

Violations No violations recorded

InspectedDoor(s)

Condition 3- Fair

WOOD:DAMAGED LOUVERDeficiency

Near Room 207Deficiency Location/Instance

1Deficiency Quantity

Quantity Uom EACH

Potential Action MAINTENANCE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Near Room 207

Violations No violations recorded

InspectedFloor Finish

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedStalls

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

InspectedWalls

Condition 2- Between Good and Fair

PLASTER:CRACKS/SPALLINGDeficiency

3rd Floor - Boys Toilet RoomsDeficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

Page 29 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 30: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

INTERIOR

TOILET ROOMS - STUDENTS

Walls

3rd Floor - Boys Toilet Rooms

Violations No violations recorded

CERAMIC TILE:BROKEN/ MISSINGDeficiency

5th Floor - Girls Toilet Rooms, 5th Floor -Boys Toilet RoomsDeficiency Location/Instance

10Deficiency Quantity

Quantity Uom S.F.

Potential Action REPLACE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

5th Floor - Girls Toilet Rooms

Violations No violations recorded

LIFE SAFETY Inspected

Does not existF.D. HOLDING AREA

Does not existSTEEL STAIRS

SITE Inspected

Does not existCONTAINERIZATION

InspectedDRAINAGE SYSTEM FOR ASPHALT

InspectedCatch Basins/Manhole - Surrounded by Asphalt

Condition 1- Good

No deficiencies recordedDeficiency

Does not existCulverts - Asphalt Covering

Does not existDRAINAGE SYSTEM FOR CONCRETE

Does not existDRAINAGE SYSTEM FOR SOIL

InspectedDRINKING FOUNTAINS

Condition 1- Good

No deficiencies recordedDeficiency

InspectedFENCES

Condition 2- Between Good and Fair

No deficiencies recordedDeficiency

Does not existIRRIGATION SYSTEM

InspectedPAVING

InspectedDOT Sidewalk

Does not existAsphalt

InspectedConcrete

1- GoodCondition

No deficiencies recordedDeficiency

Does not existPavers

InspectedSite Sidewalks & Walkways

InspectedAsphalt

2- Between Good and FairCondition

No deficiencies recordedDeficiency

Does not existConcrete

Does not existPavers

Page 30 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 31: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

SITE

PAVING

InspectedStudent Non-Use

Gravel Exists? No

InspectedAsphalt

3- FairCondition

CRACKS - MINORDeficiency

West of schoolDeficiency Location/Instance

200Deficiency Quantity

Quantity Uom S.F.

Potential Action MAINTENANCE

PRIORITY 3Urgency of Action

LEVEL 2Purpose of Action

Deficiency Photo 1

West of school

Violations No violations recorded

InspectedConcrete

2- Between Good and FairCondition

No deficiencies recordedDeficiency

Does not existPavers

InspectedStudent Use

Gravel Exists? No

InspectedAsphalt

1- GoodCondition

No deficiencies recordedDeficiency

InspectedConcrete

1- GoodCondition

No deficiencies recordedDeficiency

InspectedPavers

1- GoodCondition

No deficiencies recordedDeficiency

InspectedPLAYGROUNDS

SchoolyardInstance

Benches

Instance on Schoolyard Does not exist

Fence

Instance on Schoolyard Does not exist

Pavement

Instance on Schoolyard Does not exist

Play Equipment

Instance on Schoolyard Inspected

1- GoodInstance Condition

No deficiencies recordedDeficiency

Safety Surfacing

Instance on Schoolyard Inspected

1- GoodInstance Condition

No deficiencies recordedDeficiency

Page 31 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)

Page 32: NYC Department of Education Building Condition Assessment ...Principal Name Maria Velez Clare Principal Organization P.S. 361-Manhattan Meeting with Principal? Yes Principal Feedback

NYC Department of Education

Building Condition Assessment Survey 2018-2019

M061Architectural Inspection

Question Response

SITE

PLAYGROUNDS

Unpaved Area

Instance on Schoolyard Does not exist

InspectedPLAYING SURFACE

InspectedPlaying Field

Condition 1- Good

No deficiencies recordedDeficiency

SchoolyardInstance

Does not existRunning Track

Does not existRETAINING WALLS

InspectedSEATING

InspectedBenches

Does not existConcrete

InspectedMetal/Wood/Plastic

1- GoodCondition

No deficiencies recordedDeficiency

Does not existBleachers

Does not existSITE WALLS (NOT RETAINING WALLS)

Does not existSTAIRS/RAMPS: EXTERIOR

Page 32 of 32 Print Date: 7/3/2019Mobile Validity Version 2.0 (P)