SUBMITTAL NUMBER: 223300-01.03 OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL SUBMITTAL DETAILS: REVIEWERS: SUBJECT: ELECTRIC DOMESTIC WATER HEATERS -RESUBMITTED 3 TIME(S) DATE RECIEVED: Mar 03, 2015 DISCIPLINE: Electrical PRIMARY: TAD RIVENBARK [email protected] SCOTT BURCHFILED [email protected] MATERN ENGINEERING PHN: (407) 740-5020 FAX: (407) 740-0365 MATERN ENGINEERING PHN: FAX: SECONDARY: PRIORITY STATUS: 2-STANDARD REVIEWER DUE DATE: 3/13/2015 SPECIFICATION REF: DWG REF. NONE DWG TITLE: NO OF ITEMS: ITEM DESCRIPTI REVIEW STATUS: COMMENTS: CONTRACTOR/CM: : WILLIAMS COMPANY : BRAD KUBIN 2301 SILVER STAR RD. ORLANDO, FL, 32809 (407) 295-2530 FAX:(407) 297-0459 PLEASE SEE A/E COMMENTS FURNISH AS MARKED RETURNED ITEMS: DATE RETURNED TO CM: 3/6/2015 BUILDING REFERENCE: 1 Product Literature(s) PAGE 1 OF 1 RHODES + BRITO ARCHITECTS INC. : 605 E. ROBINSON STREET, SUITE 750 : ORLANDO, FL. : 32801 : 407.648.7288 : FAX.648.7289 cc: OWNER : CALVIN WOOLFOLK 6501 MAGIC WAY, BLDG. 200 ORLANDO, FL, 32809 (407) 317-3700 FAX:(407) 317-3768 R+B FILE: : 13017-0001.X6

Upload: others

Post on 29-Oct-2019

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

SUBMITTAL NUMBER: 223300-01.03

OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL

SUBMITTAL DETAILS:

REVIEWERS:

SUBJECT: ELECTRIC DOMESTIC WATER

HEATERS -RESUBMITTED 3 TIME(S)

DATE RECIEVED: Mar 03, 2015

DISCIPLINE: Electrical

PRIMARY: TAD RIVENBARK

[email protected]

SCOTT BURCHFILED

[email protected]

MATERN ENGINEERING

PHN: (407) 740-5020

FAX: (407) 740-0365

MATERN ENGINEERING

PHN:

FAX:

SECONDARY:

PRIORITY STATUS: 2-STANDARD

REVIEWER DUE DATE: 3/13/2015

SPECIFICATION REF:

DWG REF. NONE

DWG TITLE:

NO OF ITEMS: ITEM DESCRIPTI

REVIEW STATUS:

COMMENTS:

CONTRACTOR/CM:

: WILLIAMS COMPANY: BRAD KUBIN 2301 SILVER STAR RD. ORLANDO, FL, 32809 (407) 295-2530 FAX:(407) 297-0459

PLEASE SEE A/E COMMENTS

FURNISH AS MARKED

RETURNED ITEMS:

DATE RETURNED TO CM: 3/6/2015

BUILDING REFERENCE:

1 Product Literature(s)

PAGE 1 OF 1RHODES + BRITO ARCHITECTS INC. : 605 E. ROBINSON STREET, SUITE 750 : ORLANDO, FL. : 32801 : 407.648.7288 : FAX.648.7289

cc:

OWNER : CALVIN WOOLFOLK 6501 MAGIC WAY, BLDG. 200 ORLANDO, FL, 32809 (407) 317-3700

FAX:(407) 317-3768

R+B FILE: : 13017-0001.X6

michele
Byron
101374
Received
Page 2: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando | Fort Myers | Jacksonville | Tampa | www.matern.net

Registered: FLORIDA * GEORGIA* LOUISIANA * NORTH CAROLINA * SOUTH CAROLINA * TEXAS * TENNESSEE * VIRGINIA

SUBMITTAL DATA REVIEW COMMENTS Date: March 6, 2015 Project: OCPS-Clay Springs ES By: Kevin King Submittal: Electric Domestic Water

Heaters And Accessories

MPE Project No: 2013-224 Data No.: 22 33 00-01.01 Submittal No.: 003 Contractor’s I.D.: Heichel

Class: Basis of Design (1) Equal (2) Substitution (3)

ACTION CODE X A No exceptions taken. X B Make corrections noted. C Revise and Resubmit. D Submit Specified Item. E Rejected. N Review not required.

THE FOLLOWING COMMENTS SHALL BE CONSIDERED AN INTEGRAL PART OF THE SUBMITTAL DATA REVIEW. REVIEW OF THIS DATA IS ONLY FOR CONFORMANCE WITH THE DESIGN CONCEPT AS GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR: QUANTITIES, FUNCTIONS, DIMENSIONS AND COORDINATION OF THE WORK WITH OTHER TRADES. Action Code “B”: Coordinate all electrical requirements with the electrical contractor. Action Code “A”: All other data submitted.

END OF SUBMITTAL DATA REVIEW COMMENTS

Page 3: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

SUBMITTAL NUMBER: 22330001.03

OCPS CLAY SPRINGS ES SUBMITTAL ASSIGNMENT MEMO

SUBMITTAL DETAILS: REVIEWERS:

SUBJECT: ELECTRIC DOMESTIC WATER

HEATERS -RESUBMITTED 3 TIME(S)

DATE RFI RECIEVED: Mar 03, 2015

DISCIPLINE: Electrical

PRIMARY: TAD RIVENBARK

[email protected]

SCOTT BURCHFILED

[email protected]

MATERN ENGINEERING

PHN: (407) 740-5020FAX: (407) 740-0365

MATERN ENGINEERING

PHN:

FAX:

SECONDARY:

PRIORITY STATUS: 2-STANDARD

REVIEWER DUE DATE: 3/13/2015

SPECIFICATION REF:

DWG REF. NONE

DWG TITLE:

REVIEW STATUS:

THIS SUBMITTAL IS ISSUED TO YOU FOR YOUR REVIEW. PLEASE RESPOND AND RETURN...WITH THIS COMPLETED SAM TRANSMITTAL...TO MICHELE BUDAY-URDANETA NO LATER THAN: 3/13/2015. PLEASE COMPLETE REVIEW STATUS AT RIGHT

SUBMITTAL CONTENTS:

NO OF ITEMS: ITEM DESCRIPTION

(please print)THIS SUBMITTAL WAS REVIEWED BY :

RE-SUBMIT WITH ITEMS

NOT REVIEWED

REJECTED

REVISE AND RESUBMIT

FURNISHED AS MARKED

REVIEWED

COMMENTS:

1 PRODUCT LITERATURE(S)

cc:

OWNER : CALVIN WOOLFOLK

6501 MAGIC WAY, BLDG. 200

ORLANDO, FL, 32809

R+B FILE: : 13017-0001.X6CONTR/CM: : WILLIAMS COMPANY

: BRAD KUBIN

2301 SILVER STAR RD.

Page 4: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

SUBMITTAL NUMBER: 22330001.03

OCPS CLAY SPRINGS ES SUBMITTAL ASSIGNMENT MEMO

SUBMITTAL DETAILS: REVIEWERS:

SUBJECT: ELECTRIC DOMESTIC WATER

HEATERS -RESUBMITTED 3 TIME(S)

DATE RFI RECIEVED: Mar 03, 2015

DISCIPLINE: Electrical

PRIMARY: TAD RIVENBARK

[email protected]

SCOTT BURCHFILED

[email protected]

MATERN ENGINEERING

PHN: (407) 740-5020FAX: (407) 740-0365

MATERN ENGINEERING

PHN:

FAX:

SECONDARY:

PRIORITY STATUS: 2-STANDARD

REVIEWER DUE DATE: 3/13/2015

SPECIFICATION REF:

DWG REF. NONE

DWG TITLE:

REVIEW STATUS:

THIS SUBMITTAL IS ISSUED TO YOU FOR YOUR REVIEW. PLEASE RESPOND AND RETURN...WITH THIS COMPLETED SAM TRANSMITTAL...TO MICHELE BUDAY-URDANETA NO LATER THAN: 3/13/2015. PLEASE COMPLETE REVIEW STATUS AT RIGHT

SUBMITTAL CONTENTS:

NO OF ITEMS: ITEM DESCRIPTION

(please print)THIS SUBMITTAL WAS REVIEWED BY :

RE-SUBMIT WITH ITEMS

NOT REVIEWED

REJECTED

REVISE AND RESUBMIT

FURNISHED AS MARKED

REVIEWED

COMMENTS:

1 PRODUCT LITERATURE(S)

cc:

OWNER : CALVIN WOOLFOLK

6501 MAGIC WAY, BLDG. 200

ORLANDO, FL, 32809

R+B FILE: : 13017-0001.X6CONTR/CM: : WILLIAMS COMPANY

: BRAD KUBIN

2301 SILVER STAR RD.

Page 5: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Submittal Approval Form

PROJECT: CLAY SPRINGS ELEMENTARY SCHOOL

DATE: ___ __________________ ______

SUBCONTRACTOR NAME: __

SUBCONTRATOR ADDRESS: ______________________________ ____

NUMBER AND TITLE OF SPECIFICATION SECTION:

Contractor’s Submittal Stamp Architect/ Engineer’s Submittal Stamp

Heichel Plumbing

22 33 00 - Electric Domestic Water Heaters and Accessories - PD

3/3/15

3/3/15

katrinae
Accepted
jordan
Submittal Stamp-Jordan
kking
New Stamp
Page 6: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Spec#Spec#Spec#Spec# Table of ContentsTable of ContentsTable of ContentsTable of Contents

1 ............ EWH-1-1EWH-1-1EWH-1-1EWH-1-1

2 LOCHINVAR HCX15119 480/3 15KW 119 GALLON HI-POWER WATER HEATER

3 ............ EWH-1-2 & EWH-2-1EWH-1-2 & EWH-2-1EWH-1-2 & EWH-2-1EWH-1-2 & EWH-2-1

4 LOCHINVAR ESW030CD 277/1 3KW 30 GALLON LIGHT DUTY WATER HEATER

5 ............ EWH-1-3/EWH-2-2EWH-1-3/EWH-2-2EWH-1-3/EWH-2-2EWH-1-3/EWH-2-2

6 LOCHNVR EJW020GS 20GAL 277V 3.0KW ELECTRICWATER HEATER

7 ............ EWH-1-4 & EWH-1-5EWH-1-4 & EWH-1-5EWH-1-4 & EWH-1-5EWH-1-4 & EWH-1-5

8 EEMAX MB008277T ACCUMIX 277V HEATER

9 ............ TET-1TET-1TET-1TET-1

10 WATTS DETA-30 0212029 1 M 15GAL POTABLE WTR EXPTANK ASME

11 ............ TET-2TET-2TET-2TET-2

12 WATTS DETA-5 0212026 3/4 M 3.5GAL POTABLE WTREXP TANK ASME

Page 7: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

1

Beery, Jason

Subject: FW: Copper elements

FromSentTo: BCc: RSubj FinalreplaOrlan Than DavSenio Loch9695 P: 40

Noteuse oappliunaustrictname

m: David Baket: Thursday, JBass, Kevin Rex Prince ject: Copper

ly got the ansaceable. Writendo not Nash

nks,

e Baker or District Sale

hinvar, LLC –Delegates Dr.

07.362.8051 |

e: This e-maof the specificable privil

uthorized usetly prohibiteed above by

er [mailto:dbaJanuary 22, 2

elements

swer from Nae that in the dville for orde

es Manager

– Orlando ReSuite 502 | OF: 407.855.848

| Lochinvar

il may contafic individuaege. If you ae, disseminaed. If you havy telephone. T

aker@lochinv2015 6:03 PM

ashville. Yes wdescription ofr entry….

egional FacilOrlando, FL 32885

r, LLC | Lebanon, TN

ain PRIVILEl(s) to whomare not an inttion or copyve received Thank you.

var.com]

we can providf the P.O. wh

ity 837

| www.Lochinvar.c

EGED and Cm it is addrestended recip

ying of this ethis e-mail i

de Copper claden ordering t

com

CONFIDENTssed. Your repient of this ee-mail or the n error, plea

d Low densityto remind us

TIAL informeceipt of thise-mail, you ainformation

ase delete it a

y immersion of this comm

mation and iss e-mail is nare hereby n

n contained iand immedia

elements thamitment and h

s intended onot intended t

notified that in it or attachately notify t

at are have it sent to

nly for the to waive anyanyhed to it, is the person

o

y

Page 8: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

A. O. Smith To Acquire Lochinvar Corporation

MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it has signed a definitive agreement to acquire Lochinvar Corporation of Lebanon, Tenn., for $418 million and will not assume Lochinvar’s existing debt.

Privately held Lochinvar is a leading manufacturer of high-efficiency boilers used in commercial and residential hydronic heating and hot water applications. A. O. Smith expects the acquisition to be accretive to earnings per share in the amount of approximately $.10 in the fourth quarter of 2011, excluding one-time purchase accounting charges and professional fees related to the acquisition, and in the range of $.40 to $.50 per share in 2012. The transaction is expected to close in the third quarter of 2011, subject to customary closing conditions and regulatory review.

“This acquisition fits squarely within our stated strategy to expand our core product offering with new technologies, which emphasize high-efficiency products that can be applied globally,” Paul W. Jones, chairman and chief executive officer, observed. “This is a significant first step in growing our diversified global water heating platform and the beginning of the redeployment of the proceeds from the sale of our Electrical Products Company.”

For the 12 months ended June 30, 2011, Lochinvar recorded sales of approximately $200 million and adjusted EBITDA of approximately $45 million. The purchase price represents an adjusted multiple of 7.5 times EBITDA when taking into account the estimated $80 million of tax benefits that A. O. Smith will receive as a result of treating the transaction as a purchase of assets for tax purposes. In addition to the fixed purchase price, privately held Lochinvar’s shareholders could earn up to an additional $35 million if certain revenue objectives are achieved by November 2012. A.O. Smith expects to achieve approximately $10 to $15 million of annual synergies over the next few years from purchasing economies and�potential global expansion opportunities.��

“The addition of Lochinvar expands our product offering and gives us access to proven high-efficiency boiler technology,” Ajita G. Rajendra, president of A. O. Smith Water Products Company, said. “The $1.1 billion North American boiler industry is in the midst of a transition to the new high-efficiency condensing technology, which we believe is growing several times faster than GDP,” he continued. “We expect high-efficiency boiler products to continue to grow at an accelerated rate for the foreseeable future.”

“We also believe there are significant growth opportunities in regions outside of North America, especially in China, for Lochinvar’s higher-efficiency boilers, as more commercial customers seek ways to save energy and reduce operating costs,” Rajendra pointed out. “This opportunity

Page 9: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

becomes even more compelling when we couple Lochinvar’s leading technology with A. O. Smith’s many years of experience, strong water heater manufacturing platform and prominent brand in China.”

“Lochinvar represents an excellent fit because of their complementary products and commitment to product engineering and technology leadership,” Rajendra observed. “And, they share our commitment to the highest levels of product quality and customer satisfaction. The Lochinvar plant and technical facility in Lebanon, Tenn., are best-in-class operations, and we are excited about the future for this campus. Lochinvar has built a strong team internally and a strong group of sales representatives. We are enthused about their becoming part of the A. O. Smith team.”

William L. Vallett, Jr., chief executive officer and president of Lochinvar, commented, “We are extremely excited about the potential benefits of combining with such a logical partner like A. O. Smith and the future prospects for our employees, customers and suppliers.”

Highlights of the transaction:

� Access to higher growth, energy efficient technology and product line expansion: Pro forma A. O. Smith sales in 2010 increase 12 percent to approximately $1.7 billion, based on Lochinvar’s sales of approximately $180 million. Lochinvar’s sales have grown at a rate of eight percent for the last five years, and A. O. Smith’s management believes that this growth rate will continue for the foreseeable future. In the last year, approximately two-thirds of Lochinvar’s residential and commercial boiler revenues have come from its well known lines of high-efficiency, condensing products. In addition, the North American commercial boiler industry is currently split between hydronic heating applications and hot water applications, and A. O. Smith currently sells very few hydronic heating systems. Given its leading technology position and presence in this segment, Lochinvar will serve as the foundation for A. O. Smith’s global residential and commercial boiler platform.

� Value creation and synergy opportunities: A. O. Smith expects annual synergies from purchasing economies and potential global expansion opportunities to be $10 to $15 million in the next few years.

� Financing and financial targets: Management expects to fund the $418 million purchase price with a combination of cash and debt, which it expects to borrow under its $425 million revolving credit facility. A. O. Smith believes the transaction will achieve management’s financial targets by delivering full-year earnings accretion of $.40 to $.50 per share in 2012 and a return in excess of the company’s cost of capital in the first year after completing the acquisition.

Lochinvar’s product offerings are highly complementary to A. O. Smith’s and include: residential and commercial high-efficiency condensing and non-condensing boilers, residential and commercial water heaters, indirect water heaters, storage tanks, solar thermal commercial water heaters, and commercial and residential pool and spa heaters.

Lochinvar’s manufacturing and product engineering operations are located in Tennessee. The purchase also includes Lochinvar Ltd., the company’s United Kingdom-based subsidiary.

Page 10: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

About A. O. Smith Corporation: A. O. Smith Corporation, with 2010 sales of nearly $1.5 billion, is one of the world’s leading manufacturers of residential and commercial water heating equipment, offering a comprehensive line featuring the best-known brands in North America and China, as well as water purification products for residential and light commercial applications. A. O. Smith, headquartered in Milwaukee, Wis., employs approximately 10,000 people at operations in the U. S., Canada, Mexico, India, China, and the Netherlands.

A. O. Smith will broadcast a live conference call at 10:00 a.m. (Eastern Daylight Time) Tuesday, July 19. The call can be heard on the company’s web site, www.aosmith.com. An audio replay of the call will be available on the company’s web site after the live event.

Forward-looking statements This release contains statements that the company believes are “forward-looking statements” within the meaning of the Private Securities Litigation Reform Act of 1995. Forward-looking statements generally can be identified by the use of words such as “may,” “will,” “expect,” “intend,” “estimate,” “anticipate,” “believe,” “forecast,” “guidance” or words of similar meaning. These forward-looking statements are subject to risks and uncertainties that could cause actual results to differ materially from those anticipated as of the date of this release. Important factors that could cause actual results to differ materially from these expectations include, among other things, the following: the failure to receive, on a timely basis or otherwise, the required approvals from the government or regulatory agencies (including the terms of such approvals) for the sale of Electrical Products Company or the Lochinvar acquisition; the risk that a condition to closing of the sale of Electrical Products Company or the purchase of Lochinvar may not be satisfied;; difficulties in integrating the Lochinvar acquisition or achieving the stated accretion, cost synergies and/or global expansion opportunities; weakening in the high efficiency boiler market or slowdown in the transition from non-condensing to condensing boilers; the ability to execute our acquisition strategy; significant volatility in raw material prices; competitive pressures on the company’s businesses; inability to implement pricing actions; instability in the company’s water products markets; further weakening in housing construction; further weakening in commercial construction; timing of any recoveries in housing or commercial construction; a slowdown in the Chinese economy; adverse general economic conditions and capital market deterioration; and the impact of accounting for acquisitions on the company’s financial statements. Forward-looking statements included in this press release are made only as of the date of this release, and the company is under no obligation to update these statements to reflect subsequent events or circumstances. All subsequent written and oral forward-looking statements attributed to the company, or persons acting on its behalf, are qualified entirely by these cautionary statements.

Page 11: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Spec Seq#: 1

EWH-1-1

Page 12: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

IMMERSION THERMOSTAT - STANDARD HI-POWER® COMMERCIAL ELECTRIC WATER HEATERS

STANDARD HI-POWER®

WATER HEATERSubmittal Sheet

HPI-Sub-01a

JOB NAME ______________________________________________________________________LOCATION ______________________________________________________________________ENGINEER______________________________________________________________________WHOLESALER __________________________________________________________________MECH. CONTRACTOR ___________________________________________________________MODEL NO. _____________________________________________________________________RECOVERY RATE IN GPH_______________________________________@________°F RISEGALLON CAPACITY_____________________________________________________________VOLTAGE/PHASE________________________________________________________________KW_____________________________________________________________________________NOTES

Standard Features

• Meets ASHRAE Energy Efficiency Standards• 300 psi test pressure, 150 psi working pressure• Tank Saver Anode• Plated Incoloy, Low Watt Density Element• Energy Cut-Off• Internal Fusing when Current Exceeds 48 Amps• 180°F Operation Approved• ASME Temperature and Pressure Relief Valve• Non-CFC Foam Insulation• Hinged Door Access• 3 Year Limited Tank Warranty, 1 Year Limited Parts Warranty

(see warranty for details)

Spec Seq#: 2

kevin.bass
Typewritten Text
EWH-1-1
jason.beery
Typewritten Text
**REPLACEABLE COPPER CLAD LOW DENSITY IMMERSION ELEMENTS WILL BE PROVIDED INSTALLED FROM THE FACTORY**
jason.beery
Typewritten Text
jason.beery
Rectangle
jason.beery
Line
Page 13: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Dimensions & Specifications

For Ease In OrderingBy Model Number

H C X 45 080

HI-POW

ER

IMM

ERSION

THERMO

STATVO

LTAGE

KILOW

ATT

GALLO

N

CAPACITY

This heater is a 480 volt, 3 phase, 45 KW, 80 gallonStandard Hi-Power model

with immersion thermostats.

Model Gallon GPH @ Number of ShippingNumber KW Capacity 100°F Rise Elements A B C Weight

HC(X)06 050 6 50 25 3 55-3/4” 21-3/4” 27” 265HC(X)09 050 9 50 37 3 55-3/4” 21-3/4” 27” 265HC(X)12 050 12 50 49 3 55-3/4” 21-3/4” 27” 265HC(X)13 050 13.5 50 55 3 55-3/4” 21-3/4” 27” 265HC(X)15 050 15 50 61 3 55-3/4” 21-3/4” 27” 265HC(X)18 050 18 50 74 3** 55-3/4” 21-3/4” 27” 265HC(X)24 050 24 50 98 6 55-3/4” 21-3/4” 27” 265HC(X)27 050 27 50 111 6 55-3/4” 21-3/4” 27” 265HC(X)30 050 30 50 123 6 55-3/4” 21-3/4” 27” 265HC(X)36 050 36 50 148 6*** 55-3/4” 21-3/4” 27” 265HC(X)40 050 40.5 50 166 9 55-3/4” 21-3/4” 27” 265HC(X)45 050 45 50 194 9 55-3/4” 21-3/4” 27” 265HC(X)54 050 54 50 221 9 55-3/4” 21-3/4” 27” 265HC(X)06 080 6 80 25 3 60-1/4” 25-1/2” 31” 280HC(X)09 080 9 80 37 3 60-1/4” 25-1/2” 31” 280HC(X)12 080 12 80 49 3 60-1/4” 25-1/2” 31” 280HC(X)13 080 13.5 80 55 3 60-1/4” 25-1/2” 31” 280HC(X)15 080 15 80 61 3 60-1/4” 25-1/2” 31” 280HC(X)18 080 18 80 74 3** 60-1/4” 25-1/2” 31” 280HC(X)24 080 24 80 98 6 60-1/4” 25-1/2” 31” 280HC(X)27 080 27 80 111 6 60-1/4” 25-1/2” 31” 280HC(X)30 080 30 80 123 6 60-1/4” 25-1/2” 31” 280HC(X)36 080 36 80 148 6*** 60-1/4” 25-1/2” 31” 280HC(X)40 080 40.5 80 166 9 60-1/4” 25-1/2” 31” 280HC(X)45 080 45 80 194 9 60-1/4” 25-1/2” 31” 280HC(X)54 080 54 80 221 9 60-1/4” 25-1/2” 31” 280HC(X)06 119 6 119 25 3 62-1/4” 29-1/2” 35” 390HC(X)09 119 9 119 37 3 62-1/4” 29-1/2” 35” 390HC(X)12 119 12 119 49 3 62-1/4” 29-1/2” 35” 390HC(X)13 119 13.5 119 55 3 62-1/4” 29-1/2” 35” 390HC(X)15 119 15 119 61 3 62-1/4” 29-1/2” 35” 390HC(X)18 119 18 119 74 3** 62-1/4” 29-1/2” 35” 390HC(X)24 119 24 119 98 6 62-1/4” 29-1/2” 35” 390HC(X)27 119 27 119 111 6 62-1/4” 29-1/2” 35” 390HC(X)30 119 30 119 123 6 62-1/4” 29-1/2” 35” 390HC(X)36 119 36 119 148 6*** 62-1/4” 29-1/2” 35” 390HC(X)40 119 40.5 119 166 9 62-1/4” 29-1/2” 35” 390HC(X)45 119 45 119 194 9 62-1/4” 29-1/2” 35” 390HC(X)54 119 54 119 221 9 62-1/4” 29-1/2” 35” 390

IMMERSION THERMOSTAT w/ CONTACTORSVOLTAGE SCHEDULE

T - 208V / 1 or 3 PH W - 277V / 1 PHP - 240V / 1 or 3 PH X - 480V / 1 or 3 PH

C

CONDUITOPENING

1-1/4”WATEROUTLET

B

A

5-1/4”

1-1/4” INLETOPENING

DRAINVALVE

T&P

AMPERAGE TABLESingle Phase Three Phase

KW 208V 240V 277V 480V 208V 240V 480V 6 28.8 25.0 21.7 12.5 16.7 14.4 7.2 9 43.3 37.5 32.5 18.8 25.0 21.7 10.8 12 57.7 50.0 43.3 25.0 33.3 28.9 14.4 13.5 64.9 56.3 48.7 28.1 37.5 32.5 16.2 15 72.1 62.5 54.2 31.3 41.6 36.1 18.0 18 86.5 75.0 65.0 37.5 50.0 43.3 21.7 24 115.4 100.0 86.6 50.0 66.6 57.7 28.9 27 129.8 112.5 97.5 56.3 74.9 65.0 32.5 30 144.2 125.0 108.3 62.5 83.3 72.2 36.1 36 173.1 150.0 130.0 75.0 99.9 86.6 43.3 40.5 194.7 168.8 146.2 84.4 112.4 97.4 48.7 45 216.9 187.5 162.5 93.8 124.9 108.3 54.1 54 N/A 225.0 194.9 112.5 149.9 129.9 65.0

**208V models are confi gured with 6 elements, ***208V models are confi gured with 9 elements, Note: 208V - 54KW models are factory assembled only. They are not fi eld convertible.

HLW

© Lochinvar, LLC - 5/14 - Printed in U.S.A.

Lochinvar, LLC 300 Maddox Simpson ParkwayLebanon, Tennessee 37090P: 615.889.8900 / F: 615.547.1000

www.Lochinvar.com

Spec Seq#: 2

kevin.bass
Line
jason.beery
Rectangle
jason.beery
Line
jordan
Highlight
jordan
Highlight
Page 14: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Spec Seq#: 3

EWH-1-2 & EWH-2-1

Page 15: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS

LIGHT DUTYCOMMERCIAL ELECTRIC

WATER HEATERSubmittal SheetCLD-Sub-04

JOB NAME ______________________________________________________________________ LOCATION ______________________________________________________________________ ENGINEER____________________________________________________________________

WHOLESALER __________________________________________________________________MECH. CONTRACTOR ___________________________________________________________MODEL NO. _____________________________________________________________________RECOVERY RATE IN GPH_______________________________________@________°F RISEGALLON CAPACITY_____________________________________________________________VOLTAGE/PHASE________________________________________________________________KW_____________________________________________________________________________NOTES

Standard Features

• Meets ASHRAE Energy Efficiency Standards.• 300 psi Test Pressure, 150 psi Working Pressure.• Glass-Lined Steel Tank• Non-CFC Foam Insulation• Adjustable Thermostats• Automatic Overheat Protection• Tank Saver Anode• ASME Temperature and Pressure Relief Valve• 3 Year Limited Tank Warranty, 1 Year Limited Parts Warranty

(See warranty for details)

Spec Seq#: 4

30 Gal.277/1 Phase

Clay Springs Elementary School

Lochnivar ESW030CD 277/1

3 KW

kevin.bass
Typewritten Text
EWH-1-2/EWH-2-1
jason.beery
Typewritten Text
jason.beery
Typewritten Text
**REPLACEABLE COPPER CLAD LOW DENSITY IMMERSION ELEMENTS WILL BE PROVIDED INSTALLED FROM THE FACTORY**
jason.beery
Rectangle
Page 16: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Dimensions & Specifications

Model Gallon Shipping Number Capacity A B C D WeightPoint-of-Use Models EJW006CS 6 15-1/2” 14-1/4” 11” - 35EJW010CS 10 18-1/4” 18” 12-1/2” - 54EJW015CS 15 26” 18” 20-1/2” - 58EJW020CS 20 22-1/4” 21-3/4” 15-1/2” - 73Short Models ESX030KD 30 31” 21-3/4” 24-1/4” 8” 100ESX040KD 40 32-1/4” 24” 25-1/2” 8” 125ESX050KD 50 32-1/4” 26-1/2” 25-1/4” 8” 166Tall ModelsETX030KD 30 34-1/2” 20-1/2” - 8” 98ETX040KD 40 45-1/4” 20-1/2” - 8” 113ETX050KD 50 55” 20-1/2” - 8” 131ETX065KD 66 60-3/4” 21-3/4” - 8” 176ETX080KD 80 59-1/2” 24” - 8” 211ETX120KD 119 62-1/2” 29-1/2” - 8” 326

ALTERNATE OUTLET3/4” (FEMALE) NPTOUTLET

3/4” (FEMALE)NPT

3/4” NPTRELIEF VALVE

OPENING

ELECTRICALCONNECTION

INLET3/4” (FEMALE)

NPT

A

B

C

FRONT VIEWEJ 6/10/15/20

TOP VIEWP.O.U. 6/10/15/20

Point-of-Use models Short models

3/4” NPT RELIEF VALVE

OPENING

BRASSDRAIN VALVE

AC

B

OUTLET3/4” (FEMALE)

NPT

2-1/2”

D

TOP VIEWES 30/40/50

FRONT VIEWES 30/40/50

3-3/4”

JUNCTIONBOX

OUTLET3/4” (FEMALE)

NPT

INLET3/4” (FEMALE)

NPT

INLET3/4” (FEMALE)

NPTD

TOP VIEWET 30 - 120

JUNCTIONBOX

3/4” NPT RELIEF VALVE

OPENING

A

B

FRONT VIEWET 30 - 120

3-3/4”

DRAINVALVE

2-1/2”

Tall models

Light Duty Commercial Models

Notes: Point of Use models are non-simultaneous circuit only. P.O.U. models available in single phase only. 6 gallon P.O.U. not available above 2500 watts or in 480 V.Short & Tall models are factory wired for three phase service and are field converted to single phase.

Voltage Schedule(EJ Models)

C 120V 1 PHJ 208V 1 PHA 240V 1 PHW 277V 1 PHV 480V 1 PH

(ES & ET Models)T 208V 3 PHP 240V 3 PHW 277V 1 PHX 480V 3 PH

MO

DEL

For Ease in Orderingby Model Number

This is a Tall Commercial Electric480 volt model with a tank capacityof 50 gallons. The upper and lower

elements are 4500 watts.

E T X 050 K D

TALL

ELEMENT Q

UANTITY

TANK CA PAC I TYW

ATTAGE

VOLTAG

E

Wattage Limits w/Simultaneous Operation

208V - 10,000W (5,000W/5,000W)240V - 11,000W (5,500W/5,500W)277V - 12,000W (6,000W/6,000W)480V - 12,000W (6,000W/6,000W)

Element Availability Schedule Recovery Rate (GPH @ °F)Wattage 120V 208V 240V 277V 480V 40°F 70°F 100°F 130°FC-1500 Yes Yes Yes Yes N/A 16 9 6 5D-1650 N/A N/A N/A N/A N/A 17 10 7 5E-2000 Yes Yes Yes Yes N/A 21 12 8 6F-2500 Yes Yes Yes Yes Yes 26 15 10 8G-3000 Yes Yes Yes Yes Yes 31 18 12 10H-3500 N/A Yes Yes N/A N/A 36 21 14 11J-4000 N/A Yes Yes Yes Yes 41 24 17 13K-4500 N/A Yes Yes Yes Yes 47 27 19 14M-5000 N/A Yes* Yes* N/A Yes* 52 30 21 16N-5500 N/A N/A Yes* N/A N/A 57 32 23 17P-6000 N/A Yes Yes Yes Yes 62 35 25 19

Notes: Max Wattage for EJ-006 is 3000W* Indicates Not Available for EJ-010 and EJ-015

5/14–Printed in U.S.A.

Lochinvar, LLC 300 Maddox Simpson ParkwayLebanon, Tennessee 37090P: 615.889.8900 / F: 615.547.1000

www.Lochinvar.com

Spec Seq#: 4

kevin.bass
Line
jason.beery
Line
jason.beery
Line
jason.beery
Line
jordan
Highlight
jordan
Highlight
jordan
Highlight
jordan
Highlight
Page 17: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Spec Seq#: 5

EWH-1-3/EWH-2-2

Page 18: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS

LIGHT DUTYCOMMERCIAL ELECTRIC

WATER HEATERSubmittal SheetCLD-Sub-04

JOB NAME ______________________________________________________________________LOCATION ______________________________________________________________________ENGINEER____________________________________________________________________WHOLESALER __________________________________________________________________MECH. CONTRACTOR ___________________________________________________________MODEL NO. _____________________________________________________________________RECOVERY RATE IN GPH_______________________________________@________°F RISEGALLON CAPACITY_____________________________________________________________VOLTAGE/PHASE________________________________________________________________KW_____________________________________________________________________________NOTES

Standard Features

• Meets ASHRAE Energy Efficiency Standards.• 300 psi Test Pressure, 150 psi Working Pressure.• Glass-Lined Steel Tank• Non-CFC Foam Insulation• Adjustable Thermostats• Automatic Overheat Protection• Tank Saver Anode• ASME Temperature and Pressure Relief Valve• 3 Year Limited Tank Warranty, 1 Year Limited Parts Warranty

(See warranty for details)

Spec Seq#: 6

277/120 Gal.

3 KW

kevin.bass
Typewritten Text
EWH-1-3/EWH-2-2
jason.beery
Text Box
CLAY SPRINGS ELEM LOCHINVAR ESW030CD 277/3 3KW
jason.beery
Text Box
CLAY SPRINGS ELEM EJW020GS 20GAL 277V 3.0KW
jason.beery
Text Box
100
jason.beery
Text Box
12
jason.beery
Typewritten Text
**REPLACEABLE COPPER CLAD LOW DENSITY IMMERSION ELEMENTS WILL BE PROVIDED INSTALLED FROM THE FACTORY**
jason.beery
Rectangle
Page 19: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Dimensions & Specifications

Model Gallon Shipping Number Capacity A B C D WeightPoint-of-Use Models EJW006CS 6 15-1/2” 14-1/4” 11” - 35EJW010CS 10 18-1/4” 18” 12-1/2” - 54EJW015CS 15 26” 18” 20-1/2” - 58EJW020CS 20 22-1/4” 21-3/4” 15-1/2” - 73Short Models ESX030KD 30 31” 21-3/4” 24-1/4” 8” 100ESX040KD 40 32-1/4” 24” 25-1/2” 8” 125ESX050KD 50 32-1/4” 26-1/2” 25-1/4” 8” 166Tall ModelsETX030KD 30 34-1/2” 20-1/2” - 8” 98ETX040KD 40 45-1/4” 20-1/2” - 8” 113ETX050KD 50 55” 20-1/2” - 8” 131ETX065KD 66 60-3/4” 21-3/4” - 8” 176ETX080KD 80 59-1/2” 24” - 8” 211ETX120KD 119 62-1/2” 29-1/2” - 8” 326

ALTERNATE OUTLET3/4” (FEMALE) NPTOUTLET

3/4” (FEMALE)NPT

3/4” NPTRELIEF VALVE

OPENING

ELECTRICALCONNECTION

INLET3/4” (FEMALE)

NPT

A

B

C

FRONT VIEWEJ 6/10/15/20

TOP VIEWP.O.U. 6/10/15/20

Point-of-Use models Short models

3/4” NPT RELIEF VALVE

OPENING

BRASSDRAIN VALVE

AC

B

OUTLET3/4” (FEMALE)

NPT

2-1/2”

D

TOP VIEWES 30/40/50

FRONT VIEWES 30/40/50

3-3/4”

JUNCTIONBOX

OUTLET3/4” (FEMALE)

NPT

INLET3/4” (FEMALE)

NPT

INLET3/4” (FEMALE)

NPTD

TOP VIEWET 30 - 120

JUNCTIONBOX

3/4” NPT RELIEF VALVE

OPENING

A

B

FRONT VIEWET 30 - 120

3-3/4”

DRAINVALVE

2-1/2”

Tall models

Light Duty Commercial Models

Notes: Point of Use models are non-simultaneous circuit only. P.O.U. models available in single phase only. 6 gallon P.O.U. not available above 2500 watts or in 480 V.Short & Tall models are factory wired for three phase service and are field converted to single phase.

Voltage Schedule(EJ Models)

C 120V 1 PHJ 208V 1 PHA 240V 1 PHW 277V 1 PHV 480V 1 PH

(ES & ET Models)T 208V 3 PHP 240V 3 PHW 277V 1 PHX 480V 3 PH

MO

DEL

For Ease in Orderingby Model Number

This is a Tall Commercial Electric480 volt model with a tank capacityof 50 gallons. The upper and lower

elements are 4500 watts.

E T X 050 K D

TALL

ELEMENT Q

UANTITY

TANK CA PAC I TYW

ATTAGE

VOLTAG

E

Wattage Limits w/Simultaneous Operation

208V - 10,000W (5,000W/5,000W)240V - 11,000W (5,500W/5,500W)277V - 12,000W (6,000W/6,000W)480V - 12,000W (6,000W/6,000W)

Element Availability Schedule Recovery Rate (GPH @ °F)Wattage 120V 208V 240V 277V 480V 40°F 70°F 100°F 130°FC-1500 Yes Yes Yes Yes N/A 16 9 6 5D-1650 N/A N/A N/A N/A N/A 17 10 7 5E-2000 Yes Yes Yes Yes N/A 21 12 8 6F-2500 Yes Yes Yes Yes Yes 26 15 10 8G-3000 Yes Yes Yes Yes Yes 31 18 12 10H-3500 N/A Yes Yes N/A N/A 36 21 14 11J-4000 N/A Yes Yes Yes Yes 41 24 17 13K-4500 N/A Yes Yes Yes Yes 47 27 19 14M-5000 N/A Yes* Yes* N/A Yes* 52 30 21 16N-5500 N/A N/A Yes* N/A N/A 57 32 23 17P-6000 N/A Yes Yes Yes Yes 62 35 25 19

Notes: Max Wattage for EJ-006 is 3000W* Indicates Not Available for EJ-010 and EJ-015

5/14–Printed in U.S.A.

Lochinvar, LLC 300 Maddox Simpson ParkwayLebanon, Tennessee 37090P: 615.889.8900 / F: 615.547.1000

www.Lochinvar.com

Spec Seq#: 6

kevin.bass
Line
jason.beery
Line
jason.beery
Line
jason.beery
Line
jordan
Highlight
jordan
Highlight
jordan
Highlight
jordan
Highlight
jordan
Highlight
Page 20: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Spec Seq#: 7

EWH-1-4 & EWH-1-5

Page 21: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

The First Ever Thermostatic Temperature Controlled Heater With Code Compliant Integrated Mixing Valve

353 Christian Street, Oxford, CT 06478(800) 543-6163 [email protected]

SPECIF ICAT IONS

electric tankless hot water heater

EEMAX ACCUMIX MT UNITS• PLUMBING ORIENTATION: 3/8” Compression

Fittings at TOP of the Unit• Eemax Exclusive Turnkey Solution• Integrated Mixing Valve Meets ASSE 1070-2004• Meets UPC 413.1 Requirements When

Properly Installed• No Scalding or Temperature Spikes• Factory Calibrated Mixing Valve and Thermostatic

Temperature Control Board for Accuracy• Product Performance Test Indicator Light• 99% Energy Efficient Reducing Your Utility Costs• Quick and Easy Installation –– Integrated Valve

Solution • On-Demand Hot Water –– Never Run Out• Factory Temperature Set to 105˚F• 0.3 GPM Turn On• Quick Temperature Ramp Up Time• Compatible with All Sensor and Non-Sensor Faucets

MODEL VOLTS kW AMPS

MT004120T 120 3.5 29A

MT005240T 240 4.8 20A

MT007240T 240 6.5 27A

MT010240T 240 9.5 40A

MT008277T 277 8.0 29A

MT010277T 277 10.0 40A

EEMAX ACCUMIX MB UNITS• PLUMBING ORIENTATION: 1/2” Compression

Fittings at BOTTOM of the Unit• Eemax Exclusive Turnkey Solution• Integrated Mixing Valve Meets ASSE 1070-2004• Meets UPC 413.1 Requirements When

Properly Installed• No Scalding or Temperature Spikes• Factory Calibrated Mixing Valve and Thermostatic

Temperature Control Board for Accuracy• Product Performance Test Indicator Light• 99% Energy Efficient Reducing Your Utility Costs• Quick and Easy Installation –– Integrated Valve

Solution • On-Demand Hot Water –– Never Run Out• Factory Temperature Set to 105˚F• 0.3 GPM Turn On• Quick Temperature Ramp Up Time• Compatible with All Sensor and Non-Sensor Faucets

MODEL VOLTS kW AMPS

MB004120T 120 3.5 29A

MB005240T 240 4.8 20A

MB007240T 240 6.5 27A

MB010240T 240 9.5 40A

MB012240T 240 11.5 50A

MB008277T 277 8.0 29A

MB010277T 277 10.0 40A

QUALITY FEATURES• Cut Energy Waste - Flow switch activates heater only

on demand (no standby heat loss) – 99% efficient.• Save Water - “Point of Use”.• Integrated Mixing Valve Solution.• Continuous Hot Water – no storage capacity to run out.• Easy Installation – only one cold or hot water line is

needed for installation – integral compression fittings for 1/2” pipe on BOTTOM or 3/8” on TOP.

• Reduces Calcification, Liming and Sedimentation.

• Reduces Installation Cost and Material – No T & P relief valve needed (check local codes).

• Compact Size – Dimensions 13.5” H x 5” W x 4” D, weight 8 lbs.• Field Serviceable Element – Replaceable cartridge element

(1 year warranty).• Warranty – Heaters are guaranteed against failure due to leaks of

“Heater Body/Element Assembly” for a period of FIVE YEARS.• High Temperature Limit Switch (ECO) – protects against element burn

out, with reset button.• ADA Compliant

* The wetted surface of this product contacted by water contains less than 0.25% lead and meets California and Vermont Lead Free laws.

PATENT PENDING TECHNOLOGY

N LEAD

MT VERSION

MB VERSION

Spec Seq#: 8

jason.beery
Line
jason.beery
Rectangle
jordan
Highlight
Page 22: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

The First Ever Thermostatic Temperature Controlled Heater With Code Compliant Integrated Mixing Valve

353 Christian Street, Oxford, CT 06478(800) 543-6163 [email protected]

* The wetted surface of this product contacted by water contains less than 0.25% lead and meets California and Vermont Lead Free laws.

© 2010 Eemax, Inc. All Rights Reserved. PATENT PENDING TECHNOLOGY

EX09001-16

SPECIF ICAT IONS

N LEAD

PRODUCT SPECIFICATIONS:Dimensions: 13.5” H x 5” W x 4” D

Weight: 8 lbs.

Cover: Steel Powder Coated

Color: Sandstone

Temperature: Factory set to 105°F

Element: Replaceable Ni Chrome cartridge insert

MT Fittings: 3/8” compression fittings at TOP of unit

MB Fittings: 1/2” compression fittings at BOTTOM of unit

UL Listed: E86887

U.S. PATENT PENDING TECHNOLOGY

WARNING: THE TEMPERATURE OF THIS HEATER HAS BEEN EEMAX FACTORY SET AT 105°F FOR HAND WASHING APPLICATIONS AND MUST NOT BE ADJUSTED. TAMPERING WITH ANY ADJUSTMENTS WILL VOID WARRANTY AND MAY CAUSE A LOSS OF COMPLIANCE TO UNIFORM PLUMBING CODE 413.1. FOR FURTHER INFORMATION PLEASE CONTACT OUR TECHNICAL SUPPORT DEPARTMENT AT 1-800-543-6163.

VOLTAGE

POWER (k

W)

# AERATORS SUPPLIED/U

NIT

SUPPLY C

IRCUITS R

EQUIRED

RECOMMENDED WIR

E SIZE

TURN-ON (G

PM)

MAX EFFECTIVE FLOW (GPM)

WATER CONNECTIO

NS

COMPRESSION FITTIN

GS

TEMP RISE AT 0.

5 GPM (F

)

TEMP RISE AT 1.

0 GPM (F

)

TEMP RISE AT 1.

5 GPM (F

)

120

240*

240*

240*

277

277

120

240*

240*

240*

240*

277

277

3.5

4.8

6.5

9.5

8.0

10.0

3.5

4.8

6.5

9.5

11.5

8.0

10.0

1

1

2

3

2

3

1

1

2

3

4

2

3

29A

20A

27A

40A

29A

40A

29A

20A

27A

40A

50A

29A

40A

10AWG

12AWG

10AWG

8AWG

10AWG

8AWG

10AWG

12AWG

10AWG

8AWG

6AWG

10AWG

8AWG

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

1/2”

1/2”

1/2”

1/2”

1/2”

1/2”

1/2”

Top

Top

Top

Top

Top

Top

Bottom

Bottom

Bottom

Bottom

Bottom

Bottom

Bottom

48°

64°

89°

––

––

––

48°

64°

89°

––

––

––

––

––

31°

44°

65°

55°

68°

24°

31°

44°

65°

79°

55°

68°

––

21°

30°

43°

36°

46°

16°

21°

30°

43°

52°

36°

46°

3/8” COMPRESSION FITTINGS AT TOP OF UNITMT PRODUCT LINE –

MT004120T

MT005240T

MT007240T

MT010240T

MT008277T

MT010277T

MB PRODUCT LINE –MB004120T

MB005240T

MB007240T

MB010240T

MB012240T

MB008277T

MB010277T

5.1 2.7

2.24.1

6.8

13.4

2.4

13.4

5.1

2.7

2.2

4.1

6.8

13.4

2.4

13.4

1/2” COMPRESSION FITTINGS AT BOTTOM OF UNITMB PRODUCT LINE –

SPECIAL DESIGN SERVICEINQUIRIES FOR UNITS FOR UNIQUE APPLICATIONS ARE WELCOME. CALL OUR TECHNICAL SERVICE DEPT. 1-800-543-6163.

PRODUCT DIAGRAM (in inches)

*240V units can be used on 208V with 25% reduced temperature output.

EEMAX SUBMITTALEngineer/Architect: _______________________________________________________________________________Job Name/Customer: _____________________________________________________________________________Location: ________________________________________________________________________________________Contractor: ______________________________________________________________________________________Representative: ___________________________________________________________________________________

HEATER SPECIFICATIONS: Quantity kW Voltage AMPS GPM

AccuMix Model # MB___________________ __________ __________ __________ __________ _________

AccuMix Model # MT ___________________ __________ __________ __________ __________ _________

MODEL # VOLTAGE

SUGGESTED SPECIFICATIONTankless Water Heater shall be an Eemax Thermostatic Model, with digital microprocessing temperature control capable of maintaining outlet temperature of +/– 1°F accuracy, and uses an ASSE 1070 approved integrated mixing valve,

__________________, with _______________ kW, _________ vac, and _________ to heat _________ GPM @ a

temperature rise of ____ degrees F. Unit shall have ABS-UL 94Vo rated cover. Element shall be replaceable cartridge insert. Unit shall have replaceable filter in the inlet connector. Element shall be iron free, Nickel Chrome material. Heater shall be fitted with 1/2” pipe compression nuts (5/8” OD) or 3/8” sleeves, to eliminate need for soldering. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal.

kW RATING AMPERAGE

Spec Seq#: 8

jason.beery
Line
jason.beery
Rectangle
Page 23: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Spec Seq#: 9

TET-1

Page 24: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Series DETAASME — Pressurized Expansion Tanks for Potable Hot Water

Models DETA 5 to DETA 210Watts Model DETA Tanks are ASME fixed bladder type pre-charged expansion tanks for commercial and industrial fresh potable hot water applications. They are designed to accept the expanded volume of hot water keeping the system pressure below the relief valve setting. The water is contained in a butyl bladder.

Features•ASMESectionVIIIConstruction

•FixedButylBladder(FDAapproved)

•StainlessSteelSystemConnection

•Prechargedto40psi(FieldAdjustable)

ConstructionShell:Carbonsteel

SystemConnection:Stainlesssteel

Bladder:Butyl(FDAapproved)

Primepaintedexterior

Pressure — TemperatureMaximum Design Pressure:

DETA5throughDETA210:150psi(10bar)

Prechargedto40psi(275kPa)

Maximum Design Temperature:240°F(115°C)

SpecificationsFurnishandinstallasshownonplansaWattsModelDETA____gallon____"diameterx____"(high)pre-chargedsteelthermalexpansion tank with a fixed butyl bladder. The tank shall have atopNPTstainlesssteelsystemconnectionanda.301"-32chargingvalveconnection(standardtirevalve)tofacilitatetheon-site charging of the tank to meet system requirements. The tankmustbeconstructedinaccordancewithSectionVIIIoftheASMEBoilerandPressureVesselCode.

Model NuMber

TaNk VoluMe GalloNs

accepTaNce VoluMe GalloNs

TaGGiNG iNforMaTioN QuaNTiTy

DETA 5 3.5 2.1

DETA 12 5 3.1

DETA 20 8 3.1

DETA 30 15 10.5

DETA 42 22 15.5

DETA 60 26 15.5

DETA 80 35 15.5

DETA 100 45 21

DETA 125 60 21

DETA 160 70 52.5

DETA 180 80 52.5

DETA 210 90 52.5

Schedule

For Potable Hot Water ApplicationsES-DETA

Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location ––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’sP.O.No. ––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

*The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight.

LEAD FREE*

Spec Seq#: 10

jason.beery
Line
jordan
Highlight
Page 25: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Thermal Expansion Tanks — Pressurized

Model NuMber sysTeM coNNecTioN dNMax. operaTiNG

pressurediMeNsioNs

WeiGhT*dia. heiGhT cin. mm (PSIG) in. mm in. mm in. mm lbs. kgs.

DETA 5 3⁄4 20 150 10 254 14 356 – – 22 10DETA 12 3⁄4 20 150 12 305 14 356 – – 28 13DETA 20 3⁄4 20 150 12 305 20 508 10 254 34 15DETA 30 1 25 150 16 406 23 584 12 305 64 29DETA 42 1 25 150 16 406 32 813 14 356 88 40DETA 60 1 25 150 16 406 34 864 14 356 93 42DETA 80 1 25 150 16 406 45 1143 14 356 109 49DETA 100 1 25 150 20 508 38 965 18 457 148 67DETA 125 1 25 150 20 508 49 1245 18 457 175 79DETA 160 11⁄2 40 150 24 610 46 1676 22 559 259 117DETA 180 11⁄2 40 150 24 610 49 1168 22 559 268 122DETA 210 11⁄2 40 150 24 610 52 1321 22 559 283 128

sysTeM coNNecTioN

charGiNG ValVe

lifT riNG

deTa 20 through deTa 210

dia.

o.a.h.

c

Dimensions — Weight

sysTeM coNNecTioN

charGiNG ValVe

dia.o.a.h.

deTa 5 and deTa 12

ES-DETA0933 ©2009Watts

USA:815ChestnutSt.,No.Andover,MA01845-6098;www.watts.comCanada:5435NorthServiceRd.,Burlington,ONT.L7L5H7;www.wattscanada.ca

A Watts Water Technologies Company

Note: Tanks are factory pre-charged at 40 psi and field adjustable. (*approximate) Lift ring on models DETA 42 through DETA 210.

Spec Seq#: 10

jason.beery
Line
jordan
Highlight
Page 26: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Spec Seq#: 11

TET-2

Page 27: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Series DETAASME — Pressurized Expansion Tanks for Potable Hot Water

Models DETA 5 to DETA 210Watts Model DETA Tanks are ASME fixed bladder type pre-charged expansion tanks for commercial and industrial fresh potable hot water applications. They are designed to accept the expanded volume of hot water keeping the system pressure below the relief valve setting. The water is contained in a butyl bladder.

Features•ASMESectionVIIIConstruction

•FixedButylBladder(FDAapproved)

•StainlessSteelSystemConnection

•Prechargedto40psi(FieldAdjustable)

ConstructionShell:Carbonsteel

SystemConnection:Stainlesssteel

Bladder:Butyl(FDAapproved)

Primepaintedexterior

Pressure — TemperatureMaximum Design Pressure:

DETA5throughDETA210:150psi(10bar)

Prechargedto40psi(275kPa)

Maximum Design Temperature:240°F(115°C)

SpecificationsFurnishandinstallasshownonplansaWattsModelDETA____gallon____"diameterx____"(high)pre-chargedsteelthermalexpansion tank with a fixed butyl bladder. The tank shall have atopNPTstainlesssteelsystemconnectionanda.301"-32chargingvalveconnection(standardtirevalve)tofacilitatetheon-site charging of the tank to meet system requirements. The tankmustbeconstructedinaccordancewithSectionVIIIoftheASMEBoilerandPressureVesselCode.

Model NuMber

TaNk VoluMe GalloNs

accepTaNce VoluMe GalloNs

TaGGiNG iNforMaTioN QuaNTiTy

DETA 5 3.5 2.1

DETA 12 5 3.1

DETA 20 8 3.1

DETA 30 15 10.5

DETA 42 22 15.5

DETA 60 26 15.5

DETA 80 35 15.5

DETA 100 45 21

DETA 125 60 21

DETA 160 70 52.5

DETA 180 80 52.5

DETA 210 90 52.5

Schedule

For Potable Hot Water ApplicationsES-DETA

Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location ––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’sP.O.No. ––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

*The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight.

LEAD FREE*

Spec Seq#: 12

jason.beery
Line
jordan
Highlight
Page 28: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

Thermal Expansion Tanks — Pressurized

Model NuMber sysTeM coNNecTioN dNMax. operaTiNG

pressurediMeNsioNs

WeiGhT*dia. heiGhT cin. mm (PSIG) in. mm in. mm in. mm lbs. kgs.

DETA 5 3⁄4 20 150 10 254 14 356 – – 22 10DETA 12 3⁄4 20 150 12 305 14 356 – – 28 13DETA 20 3⁄4 20 150 12 305 20 508 10 254 34 15DETA 30 1 25 150 16 406 23 584 12 305 64 29DETA 42 1 25 150 16 406 32 813 14 356 88 40DETA 60 1 25 150 16 406 34 864 14 356 93 42DETA 80 1 25 150 16 406 45 1143 14 356 109 49DETA 100 1 25 150 20 508 38 965 18 457 148 67DETA 125 1 25 150 20 508 49 1245 18 457 175 79DETA 160 11⁄2 40 150 24 610 46 1676 22 559 259 117DETA 180 11⁄2 40 150 24 610 49 1168 22 559 268 122DETA 210 11⁄2 40 150 24 610 52 1321 22 559 283 128

sysTeM coNNecTioN

charGiNG ValVe

lifT riNG

deTa 20 through deTa 210

dia.

o.a.h.

c

Dimensions — Weight

sysTeM coNNecTioN

charGiNG ValVe

dia.o.a.h.

deTa 5 and deTa 12

ES-DETA0933 ©2009Watts

USA:815ChestnutSt.,No.Andover,MA01845-6098;www.watts.comCanada:5435NorthServiceRd.,Burlington,ONT.L7L5H7;www.wattscanada.ca

A Watts Water Technologies Company

Note: Tanks are factory pre-charged at 40 psi and field adjustable. (*approximate) Lift ring on models DETA 42 through DETA 210.

Spec Seq#: 12

jason.beery
Line
jordan
Highlight
Page 29: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

INSTALLATION INSTRUCTIONS

Page 30: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

1

RE-I&S

ELECTRIC WATER HEATER

THE WARRANTY ON THIS WATER HEATER IS IN EFFECT ONLY WHENTHE WATER HEATER IS INSTALLED AND OPERATED IN ACCORDANCEWITH LOCAL CODES AND THESE INSTRUCTIONS. THE MANUFACTUREROF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGE RESULTINGFROM FAILURE TO COMPLY WITH THESE INSTRUCTIONS. READTHESE INSTRUCTIONS THOROUGHLY BEFORE STARTING.

For your family’s comfort, safety and convenience, it is recommendthis water heater be installed and serviced by a plumbingprofessional.

TABLE OF CONTENTSGENERAL INFORMATION.............................................................. 1

INSTALLATION........................................................................... 1Locating The Water Heater ................................................... 1Water Connections ............................................................... 2Electrical Connections ........................................................... 3

GENERAL OPERATION .................................................................. 4Thermostat Adjustment ......................................................... 4

MAINTENANCE ............................................................................. 4

GENERAL INFORMATION

This electric water heater’s design is certified by Underwriters Laboratories (UL)and listed in accordance with UL 174. C-UL listed in accordance with CanadianNational Standard C22.2, No. 110-M90.

This water heater must be installed in accordance with local codes. In theabsence of local codes, install this water heater in accordance with the N.E.C.Reference Book (latest edition).

The warranty for this water heater is in effect only when the water heater isinstalled, adjusted, and operated in accordance with these Installation andOperating Instructions. The manufacturer will not be held liable for damageresulting from alteration and/or failure to comply with these instructions.

This water heater is design certified for installation in a mobile home.

This water heater has been designed and certified for the purpose of heatingpotable water. The installation and use of this water heater for any purposeother than the heating of potable water, may cause damage to the waterheater and create a hazardous condition and nullify the warranty.

Do not use this appliance if any part has been submerged in water. Theplumbing professional responsible for the installation of this water heatershould be contacted to inspect the appliance and to replace any part of thecontrol system, including thermostat, which has been submerged in water.

Make sure that the rating plate on the water heater is referenced for certaintythat the correct voltage is being supplied to the water heater.

A sacrificial anode is used to extend tank life. Removal of this anode, for anyreason, will nullify the warranty. In areas where water is unusually active, anodor may occur at the hot water faucet due to a reaction between the sacrificialanode and impurities in the water. If this should happen, an alternative anodemay be purchased from the supplier that installed this water heater. This willminimize the odor while protecting the tank. Additionally, the water heatershould be flushed with appropriate dissolvers to eliminate any bacteria.

INSTALLATION

Locating The Water Heater

This water heater shall NOT be installed in any location wheregasoline or flammable vapors are likely to be present, unless theinstallation is such to eliminate the probable ignition of gasoline orflammable vapors.

The location this water heater is to be installed is of utmost importance. Beforeinstalling this water heater, consult the installation section of these instructions.After reading these installation and operating instructions, select a location forthe water heater where the floor is level and is easily accessible to a powersupply and water connections. It is recommended that the water heater belocated near the center of greatest hot water usage to prevent heat lossthrough the pipes. DO NOT locate the water heater where water linescould be subjected to freezing temperatures. Locate the water heaterso that access panels and drain valves are accessible.

INSTALLATION & SERVICE MANUAL

CAUTIONIncorrect operation of this appliance may create a hazard tolife and property and will nullify the warranty.

DANGERDo not store or use gasoline or other flammable, combustible,or corrosive vapors and liquids in the vicinity of this or anyother appliance.

WARNINGWater heaters are heat producing appliances. To avoid damage or injurythere shall be no materials stored against the water heater or vent-air intakesystem and proper care shall be taken to avoid unnecessary contact(especially by children) with the water heater. UNDER NOCIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH ASGASOLINE OR PAINT THINNER BE USED OR STORED IN THEVICINITY OF THIS WATER HEATER OR IN ANY LOCATION FROMWHICH FUMES COULD REACH THE WATER HEATER.

IMPORTANTBefore proceeding, please inspect the water heater and components forpossible damage. DO NOT install any damaged components. If damage isevident then please contact the supplier where the water heater waspurchased or the manufacturer listed on the rating plate for replacementparts.

Page 31: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

2

RE-I&S

Water heater corrosion and component failure can be caused by the heatingand breakdown of airborne chemical vapors. Examples of some typicalcompounds that are potentially corrosive are: spray can propellants, cleaningsolvents, refrigerator and air conditioning refrigerants, swimming pool chemicals,calcium or sodium chloride, waxes and process chemicals. These materials arecorrosive at very low concentration levels with little or no odor to reveal theirpresence. NOTE: DAMAGE TO THE WATER HEATER CAUSED BYEXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THEWARRANTY. DO NOT OPERATE THE WATER HEATER IF EXPOSUREHAS OR WILL OCCUR. DO NOT STORE ANY POTENTIALLY CORROSIVECOMPOUNDS IN THE VICINITY OF THE WATER HEATER.

This water heater must be located in an area where leakage of the tank or waterline connections and the combination temperature and pressure relief valve willnot result in damage to the area adjacent to the water heater or to lower floorsof the structure. When such locations cannot be avoided, a suitable drain panmust be installed under the water heater. The drain pan must be no greaterthan 1-1/2 in. (3.8 cm) deep and have a minimum length and width of at least4 in. (10.2 cm) greater than the diameter of the water heater. The drain pan,as described above, can be purchased from your plumbing professional. Thedrain pan must be piped to an adequate drain. The piping must be pitched forproper drainage.

WATER CONNECTIONS

NOTE:BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE.After shutting the main water supply valve, open a faucet to relieve the waterline pressure to prevent any water from leaking out of the pipes while makingthe water connections to the water heater. After the pressure has beenrelieved, close the faucet. The COLD water inlet and HOT water outlet areidentified on top of the water heater. The fittings at the cold water inlet and hotwater outlet are dielectric waterway fittings with 3/4" NPT tapered male threads.Make the proper plumbing connections between the water heater and theplumbing system in the house. Install a shut-off valve in the cold water supplyline.

If this water heater is installed in a closed water supply system, such as the onehaving a back-flow preventer in the cold water supply, provisions shall be madeto control thermal expansion. DO NOT operate this water heater in a closedsystem without provisions for controlling thermal expansion. Your water supplieror local plumbing inspector should be contacted on how to control this situation.After installation of the water lines, open the main water supply valve and fillthe water heater. While the water heater is filling, open several hot water

faucets to allow air to escape from the water system. When a steady streamof water flows through the faucets, close them and check all water connectionsfor possible leaks. NEVER OPERATE THE WATER HEATER WITHOUT FIRSTBEING CERTAIN IT IS FILLED WITH WATER.

CAUTIONIf sweat fittings are to be use, DO NOT apply heat to the nipples on top ofthe water heater. Sweat the tubing to the adapter before fitting the adapterto the water connections. It is imperative that heat is not applied to thenipples containing a plastic liner.

WARNINGFor protection against excessive temperatures and pressure, installtemperature and pressure protective equipment required by local codes,but not less than a combination temperature and pressure relief valvecertified by a nationally recognized testing laboratory that maintainsperiodic inspection of production of listed equipment or materials asmeeting the requirements for Relief Valves and Automatic Gas ShutoffDevices for Hot Water Supply Systems, ANSI Z21.22 and the StandardCAN1-4.4, Temperature, Pressure, Temperature and Pressure Relief Valvesand Vacuum Relief Valves. The combination temperature and pressurerelief valve shall be marked with a maximum set pressure not to exceedthe maximum working pressure of the water heater. The combinationtemperature and pressure relief valve shall also have an hourly ratedtemperature steam BTU discharge capacity not less than the hourlyinput rating of the water heater.

Install the combination temperature and pressure relief valve into theopening provided and marked for this purpose on the water heater.

NOTE: Some models may already be equipped or supplied with acombination temperature and pressure relief valve. Verify that thecombination temperature and pressure relief valve complies with localcodes. If the combination temperature and pressure relief valve doesnot comply with local codes, replace it with one that does. Follow theinstallation instructions above on this page.

Install a discharge line so that water discharged from the combinationtemperature and pressure relief valve will exit within six (6) inches(15.3 cm) above, or any distance below the structural floor and cannotcontact any live electrical part. The discharge line is to be installed toallow for complete drainage of both the temperature and pressure reliefvalve and the discharge line. The discharge opening must not besubjected to blockage or freezing. DO NOT thread, plug or cap thedischarge line. It is recommended that a minimum of four (4) inches(10.2 cm) be provided on the side of the water heater for servicing andmaintenance of the combination temperature and pressure relief valve.

Do not place a valve between the combination temperature and pressurerelief valve and the tank.

IMPORTANTFAILURE TO INSTALL AND MAINTAIN A NEW, LISTED ¾” X ¾”TEMPERATURE PRESSURE RELIEF VALVE WILL RELEASE THEMANUFACTURER FROM ANY CLAIM WHICH MIGHT RESULTFROM EXCESSIVE TEMPERATURE AND PRESSURES.

Page 32: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

3

RE-I&S

CAUTIONINCREASING THE THERMOSTAT SETTING ABOVE THE PRESET TEMPERATUREMAY CAUSE SEVERE BURNS AND CONSUME EXCESSIVE ENERGY. HOTTERWATER INCREASES THE RISK OF SCALD INJURY.

WARNINGHydrogen gas can be produced in an operating water heaterthat has not had water drawn from the tank for a long periodof time (generally two weeks or more). Hydrogen gas isextremely flammable. To reduce the risk of injury under theseconditions, it is recommended that the hot water faucet to beopened for several minutes at the kitchen sink before using anyelectrical appliance which is connected to the hot water system.If hydrogen is present, there will probably be an unsual soundsuch as air escaping through the pipe as hot water begins toflow. There should be no smoking or open flame near the faucetat the time it is open.

This water heater can deliver scalding temperature water at any faucet in thesystem. Be careful whenever using hot water to avoid scalding injury. Certainappliances, such as dishwashers and automatic clothes washers, may requireincreased temperature water. By setting the thermostat on this water heaterto obtain increased temperature water required by these appliances, you maycreate the potential for scald injury. To protect against injury, you should installan anti-scald tempering valve in the water system. This valve will reduce pointof discharge temperature by mixing cold and hot water in branch supply lines.Such lines are available from your local plumbing supplier. Please consult witha plumbing professional.

Tall Models (See Figure 1)

The hot and cold water connections areidentified on the top of the water heater.Connect the hot and cold water lines to theinstalled nipples using unions. Install alisted temperature-pressure relief valve inthe opening on the side of the water heater.

Figure 1

Page 33: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

4

RE-I&S

Short/Junior Models (See Figure 2)

The hot and cold water connections are identified on the side of the water heater. Connect the hot and cold water lines to the installed nipples using unions. Installa listed temperature-pressure relief valve in the opening on the side of the water heater. Install a vacuum relief anti-siphon device in the cold water inlet linewhen using the side cold water connection.

The 6 and 12 gallon models are equipped for installation with either top or side water connections. They are shipped from the factory with side nipples installedand the alternate top connections plugged. For ease of conversion, the alternate top inlet is supplied with a dip tube. If the top water connections are needed,remove the installed side nipples and the pipe plugs from the alternate top connections. Install the nipples in the top water connections and install the pipe plugsin the side connections. Install a vacuum relief anti-siphon device in the cold water inlet when using the side cold water connection.

Figure 2

Page 34: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

5

RE-I&S

Table Top Models (See Figure 3)

The hot water outlet and cold water inlet are identified on the back panel of the water heater. Remove the porcelain top by sliding it forward and lifting it off thecabinet. Care should be taken in handling the porcelain top to prevent chipping of the porcelain. Remove the four front panel screws; two at the top flange. Checkdrain valve to make sure that it is closed. Part the top fiberglass insulation to allow access to the plumbing and electrical connections. Connect the cold watersupply line and hot water outlet lines using elbows, nipples and unions as shown in the diagrams. Install a shutoff valve in the cold water inlet. Install a listedtemperature-pressure relief valve in the remaining fitting.

Figure 3

Recommended Fuse SizeVoltage

Max. Watts 120v 208v 240v 277v 480v1000 15A 10A 10A 10A 10A1250 15A 10A 10A 10A 10A1500 20A 10A 10A 10A 10A2000 25A 15A 15A 10A 10A2500 30A 15A 15A 15A 10A3000 35A 20A 20A 15A 10A3500 --- 25A 20A 20A 10A4000 --- 25A 25A 20A 15A4500 --- 30A 25A 25A 15A5000 --- 30A 30A 25A 15A5500 --- 35A 35A 25A 15A6000 --- 40A 35A 30A 20A

ELECTRICAL CONNECTIONS

Before any electrical connections are made, be sure that the water heater is fullof water and that the manual shut-off valve in the cold water supply line isopen. Check the rating plate and wiring diagram before proceeding. Thiselectric water heater was built and wired in accordance with the UnderwritersLaboratories testing approvals requirements. The temperature limiting deviceis of the manual reset, trip-free type and has been factory installed to interruptall ungrounded power supply conductors in the event of thermostat failure.Thermostats are factory set and wired in accordance with the wiring diagramfastened to the inside of the top access panel. The plumbing supplier in yourarea ordered this heater wired at the factory to comply with existing areacodes, but local utility codes may require or allow other circuitry. Consult yourlocal power company to determine the correct electrical hook-up in order tomeet local utility and building codes and in order to obtain the most economicalrates. Also check to find out if you are required to obtain a permit beforestarting the installation. The following chart shows the recommended fuse sizefor the maximum water heater wattage. The maximum wattage and ratedvoltage are shown on the water heater data plate. The water heater must bewell grounded. A green ground screw is provided at the electrical connectionpoint for connecting a ground wire.

GENERAL OPERATION

Before closing the switch to allow electric current to flow to the water heater,make certain that the water heater is full of water and that the cold water inlet

Page 35: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

6

RE-I&S

dial clockwise to increase water temperature. Replace the insulation makingsure that the controls are well covered and that the plastic terminal shield hasnot been displaced; replace the access panel. The water heater is now readyfor operation and the main switch can be closed.

MAINTENANCE

Shut off the electric power whenever the water supply to the water heater is off.Shut off the electric power and water supply, drain the heater completely toprevent freezing whenever the building is left unoccupied during the coldweather months. In order to ensure efficient operation and long tank life, drainthe water heater at least once a month through the drain valve until the waterruns clear. Failure to do this may result in noisy operation and lime andsediment buildup in the bottom of the tank. Check the temperature-pressurerelief valve to ensure that the valve has not become encrusted with lime. Liftthe lever at the top of the valve several times until the valve seats properlywithout leaking and operates freely.

The following maintenance should be performed by a qualified service technicianat the minimum periodic intervals suggested. In some installations, themaintenance interval may be more frequent depending on the amount of useand the operating conditions of the water heater. Regular inspection andmaintenance of the water heater will help to ensure safe and reliable operation.

valve is open. Complete failure of the heating elements will result if they arenot totally immersed in water at all times. When the switch is closed, theoperation of this electric water heater is automatic. The thermostats are presetto the “HOT” setting to provide a water temperature of approximately 120°F(49°C) to reduce the risk of scald injury.

Care must be taken whenever using hot water to avoid scalding injury. Certainappliances require high temperature hot water (such as dishwashers andautomatic clothes washers).

TO FILL THE WATER HEATER1. Close the water heater drain valve by turning the knob clockwise.

2. Open the cold water supply shut-off valve.

3. Open several hot water faucets to allow air to escape from the system.

4. When a steady stream of water flows from the faucets, the water heater isfilled. Close the faucets and check for water leaks at the water heater drainvalve, combination temperature and pressure relief valve and the hot andcold water connections.

TO DRAIN THE HEATERShould it become necessary to completely drain the water heater, makesure you follow the steps below:

1. Disconnect the power supply to the heater. Consult the plumbingprofessional or electric company in your area for service.

2. Close the cold water supply shut-off valve.

3. Open the drain valve on the water heater by turning the knobcounter-clockwise. The drain valve has threads on the end that will allowconnection of a standard hose coupling.

4. Open a hot water faucet to allow air to enter the system.

To refill the water heater, refer to “TO FILL THE WATER HEATER.”

THERMOSTAT ADJUSTMENT

The temperature of the water can be changed by adjusting the thermostat(s).Before any work is done on the water heater, disconnect all power to the waterheater by opening the switch at the main electrical circuit breaker or fuse box.Remove the access panels or front panel on table tops; fold the insulationoutward away from the controls. Set the thermostat(s) to the desired watertemperature using a screw driver to move the thermostat dial. The thermostathas been factory preset to approximately 120°F (49°C). Rotate the temperature

CAUTIONBefore adjusting thermostat(s), turn off power supply to the water heater.

IMPORTANTThe water heater should be inspected at a minimum of annually be a qualifiedservice technician for damaged components. DO NOT operate this water heaterif any part is found damaged .

DANGERHotter water increases the risk of scald injury. Scalding may occur withinfive (5) seconds at a temperature setting of 135°F (57°C). To protectagainst hot water injury, install an anti-scald tempering valve in the watersystem. This valve will reduce point of discharge temperature by mixingcold and hot water in branch water lines. A licensed plumbing professionalor local plumbing authority should be consulted.

WARNINGWhen lifting lever of temperature-pressure relief valve, hotwater will be released under pressure. Be certain that anyreleased water does not result in bodily injury or propertydamage.

CAUTIONScalding may occur within five (5) seconds at a temperature setting of135°F (57°C).

Figure 4

Page 36: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

7

RE-I&S

1. Annually, check the operation of the thermostat(s).

2. Bi-annually, check the seal around the heating elements for leaks. If thereis any sign of leaking, disconnect the power supply to the water heater andcontact the plumbing professional that installed this water heater or aqualified service technician.

3. At least once a year, check the combination temperature and pressure reliefvalve to ensure that the valve has not become encrusted with lime. Lift thelever at the top of the temperature-pressure relief valve several times untilthe valve seats properly without leaking and operates freely.

4. If the combination temperature and pressure relief valve on the appliancedischarges periodically, this may be due to thermal expansion in a closedwater supply system. Contact the water supplier or local plumbing inspectoron how to correct this situation. Do not plug the combination temperatureand pressure relief valve outlet for any reason.

5. Monthly, drain off a gallon of water from the water heater to remove silt andsediment.

6. A combination sacrificial anode rod/hot water outlet nipple has been installedto extend tank life. The anode rod should be inspected periodically (every2 years) and replaced when necessary to prolong tank life. Water conditionsin your area will influence the time interval for inspection and replacementof the anode rod. Contact the plumbing professional who installed the waterheater or the manufacturer listed on the rating plate for anode replacementinformation. The use of a water softener may increase the speed of anodeconsumption. More frequent inspection of the anode is needed when usingsoftened (or phosphate treated) water.

Contact your local plumbing supplier or plumbing professional for replacementparts or contact the company at the address displayed on the rating plate ofthe water heater.

For faster and better service, please provide the part name, model, and serialnumber(s) of the water heater(s) when ordering parts.

WARNINGWhen lifting lever of the combination temperature andpressure relief valve, hot water will be released under pressure.Be careful that any released water does not result in bodilyinjury or property damage.

WARNING! THIS WATER MAY BE HOT..

CAUTIONFOR YOUR SAFETY, DO NOT ATTEMPT REPAIR OF COMBINATION GASCONTROL, BURNERS OR GAS PIPING. REFER REPAIRS TO A QUALIFIEDSERVICE TECHNICIAN.

Page 37: OCPS CLAY SPRINGS ES SUBMITTAL TRANSMITTAL · A. O. Smith To Acquire Lochinvar Corporation MILWAUKEE, WIS. (July 19, 2011) —A. O. Smith Corporation (NYSE:AOS) today announced it

8

RE-I&S

Printed in USA

Notes