oem titam flow transducer

2
   T    I    T    A    N     E    N    T    E    R    P    R    I    S    E    S     L    T    D  . F L O W TRANSDUCER   DATA  SHEET  Phone (44) 01935 812790. Fax (44) 01935 812890 Web www.flowmeters.co.uk [email protected] Coldharbour Business Park, Sherborne, Dorset, DT9 4JW TITAN ENTERPR ISES LTD. 15mm compression fittings Economical  Acetal body 1½% FSD Sapphire bearings Optical sensing 2 Flow ranges Pulse output 15 Bar rating Nitrile seal 15mm fittings 0.25% Repeatability Various power options 70°C Max Flow switch option IP 54 Ideal for Drink dispensing Showers Cooling equipment Dishwashers Low viscosity fluids OEM applications This multi-range radial flow turbine meter uses a low inertia turbine supported on robust sapphire bearings. It has 15mm compression brass fittings and is available in two flow ranges, 0.25 to 6.5 and 1.5 to 30 litres per minute. There are four stan- dard configurations The basic sensor is fitted with an LED and detector, alternatively it may be fitted with a flying lead for 5V or 7-24V use or even fitted with a integral adjustable flow switch printed circu it b oard. The pulse output may be readily interfaced with almost any electronic recording device as it is an open collector transistor with an internal pull up resistor on the basic two models and without the pull resistor on the 7- 24V model. Custom leads or connectors are also available for large quantity orders for original equipment manufacturers.  

Upload: carlos-francisco-cedillo-bruzual

Post on 04-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Oem Titam Flow Transducer

7/29/2019 Oem Titam Flow Transducer

http://slidepdf.com/reader/full/oem-titam-flow-transducer 1/2

   T   I   T   A

   N

    E

   N

   T   E

   R

   P

   R

   I   S

   E

   S

    L   T   D

 .

FLOW TRANSDUCER  DATA  SHEET  

Phone (44) 01935 812790.Fax (44) 01935 812890

Web www.flowmeters.co.uk

[email protected]

Coldharbour Business Park,

Sherborne,

Dorset,

DT9 4JW

T I T A N E N T E R P R I S E SL T D .

15mm compression fittings

Economical Acetal body

1½% FSDSapphire bearingsOptical sensing2 Flow rangesPulse output15 Bar ratingNitrile seal15mm fittings0.25% RepeatabilityVarious power options70°C Max

Flow switch option

IP 54

Ideal for 

Drink dispensingShowersCooling equipmentDishwashersLow viscosity fluidsOEM applications

This multi-range radial flow turbine meter uses a low inertiaturbine supported on robust sapphire bearings. It has 15mm

compression brass fittings and is available in two flow ranges,0.25 to 6.5 and 1.5 to 30 litres per minute. There are four stan-dard configurations The basic sensor is fitted with an LEDand detector, alternatively it may be fitted with a flying lead for 5V or 7-24V use or even fitted with a integral adjustable flowswitch printed circuit board. The pulse output may be readilyinterfaced with almost any electronic recording device as it isan open collector transistor with an internal pull up resistor onthe basic two models and without the pull resistor on the 7-24V model. Custom leads or connectors are also available

for large quantity orders for original equipment manufacturers. 

Page 2: Oem Titam Flow Transducer

7/29/2019 Oem Titam Flow Transducer

http://slidepdf.com/reader/full/oem-titam-flow-transducer 2/2

Titan Enterprises Ltd, Coldharbour Business Park, Sherborne, Dorset, DT9 4JW, England. Tel 01935 812790 Fax 01935 812890 . www.flowmeters.co.uk 

Order CodesModel Flow range Linearity Typical Approx

L/Min % FSD Freq. Hz. ‘K’ Factor  

Grey 0·15 - 6·5 1.5 500 4600

Beige 1.50 - 30 1.5 600 1200

   F   l  o  w

  r  a   t  e   L   /   M

   i  n .

This rotation is detected when a turbine blade crossesa powerful infra-red light beam. The resulting output isa NPN pulse that is readily interfaced with most elec-tronic display or recording devices. The combinationof materials and technology ensures a long life prod-uct with reliable operation throughout. The flowswitch version has a potentiometer to set the switchpoint and an LED indicator to indicate flows above

this point. The output is a change in logic level thatmay be readily interfaced with a wide range of moni-toring equipment. Built in hysterisis prevents output jitter at the set point. The pulse output is still availablefor recording purposes.

0 5 50 60 70% Flow range

 Adjustment

Hysterisis at themaximum and mini-mum adjustments

Flow switch with adjustable set point

Standard Materials of constructionBody and cap - Polyacetal &

Nylon‘O’ Ring seal - NitrileBearings - SapphireEnd fittings - 15mm brass

compression

Grey

Basic flowmeter 163-000

5 Volt with lead 163-009

7 - 24 Voltwith lead 163-010

Flow switch * 163-011 

Beige 

Basic flowmeter 161-000

5 Volt with lead 161-009

7 - 24 Voltwith lead 161-010

Flow switch * 163-011

* This is a separate order codeand must be ordered as an ad-ditional item to the basic flow-meter. The maximum operat-ing temperature of the flowswitch version is 55°C.