EPFL Inovation Park / www.estia.ch Impact of the new European standard on building design Bernard PAULE / Estia, Lausanne Daylight Symposium / Paris 2019

Upload: others

Post on 28-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

Impact of the new European standard

on building design

Bernard PAULE / Estia, Lausanne

Daylight Symposium / Paris 2019

Page 2: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

• Daylight provision

• View out

• Exposure to sunlight

• Protection from glare

Daylight Symposium / Paris 2019

Page 3: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

• Daylight provision

• View out

• Exposure to sunlight

• Protection from glare

Daylight Symposium / Paris 2019

Page 4: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

2.80

5.00

5.00

Walls reflection• Ceiling : 0.80• Walls : 0.60• Floor : 0.30

Openings• Tl : 0.80• g : 0.62• Frame : 25%

Reference case-study

10°

Localization• Paris

R+3

Orientation• South

Daylight Symposium / Paris 2019

Page 5: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

Ranking on Median value

(50% of opening hours100% of the room)

Ranking on Minimum value

(50% of opening hours95% of the room)

Global ranking - Upper floor (α = 10°)(Maximum performance)

10°

Medium

Medium

Daylight Symposium / Paris 2019

Simulations : DIAL+

Page 6: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

500x500

In an unobstructed environment (obstruction angle = 10°)‣The glazing ratio (WFR) should be over 55% to reach « HIGH » level‣A glazing ratio below 40%, leads to « MINIMUM » level

Influence of window to floor ratio

Glazing ratio (WFR)42% 30%38% 35% 32%47%70% 60% 52%

10°

550x550 600x600 650x650 700x700300x300 350x350 400x400 450x450

MinimumMediumHigh

(fully glazed façades / simplified method)

Paris

Daylight Symposium / Paris 2019

Simulations : DIAL+

Page 7: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

10°

40°

22°

33°

Medium

Minimum

Minimum

No Ranking

500x500

Influence of outdoor environment(fully glazed façades / simplified method)

Daylight Symposium / Paris 2019

Simulations : DIAL+

Page 8: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

22°

500x500

Influence of Indoor photometry(fully glazed façades / simplified method)

863 Minimum

752 Minimum

641 No Ranking

Daylight Symposium / Paris 2019

Simulations : DIAL+

Page 9: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

500x500

Influence of Additional Layer

22°

(fully glazed façades / simplified method)

Daylight Symposium / Paris 2019

Minimum

No Ranking

Double skin (Tv = 0.7)

Simulations : DIAL+

Page 10: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

No shading

Influence of calculation method(fully glazed façades / Simplified & Detailed methods)

South Orientation

No shading

Static (DF) Dynamic (sDA)

Daylight Symposium / Paris 2019

10°

Simulations : DIAL+

Page 11: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

No shading Venetian Blind Fabric blind Electrochromic

Influence & Shading device(fully glazed façades / Simplified & Detailed methods)

10°

South Orientation

No shading

Daylight Symposium / Paris 2019

Static (DF) Dynamic (sDA)

Simulations : DIAL+

Page 12: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

Influence of Room localization

Daylight Symposium / Paris 2019

Simulations : DIAL+

Page 13: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

+7.5 kWh/m2.y

Impact on Heating loads

Daylight Symposium / Paris 2019

1m window sill

Simulations : DIAL+

Page 14: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

+5.9 kWh/m2.y

Impact on Cooling loads

Daylight Symposium / Paris 2019

Simulations : DIAL+

Page 15: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

Electric lighting loads [kWh/m2]

-0.8 kWh/m2.y

Impact on Electric Lighting Loads

Daylight Symposium / Paris 2019

Simulations : DIAL+

Page 16: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

‣ It is not really suitable for urban environments

‣ It eliminates rooms with a Depth / Height ratio > 2

‣ It eliminates buildings with double skin

‣ It encourages the realization of facade entirely glazed

General feeling

‣ The requirements are extremely demanding 😬

😡

🧐

😏

😀

‣ EN-17037 addresses a very broad scope of issues 😀

Daylight Symposium / Paris 2019

‣ It could result in an overal increase of energy consumption 😬

Page 17: on building design/media/com/velux days in...EPFL Inovation Park / •Daylight provision •View out •Exposure to sunlight •Protection from glare Daylight Symposium / Paris 2019

EPFL Inovation Park / www.estia.ch

Thank you !