optimus green sound level meters for environmental
TRANSCRIPT
BASIC OCCUPATIONAL ENVIRONMENTAL ADVANCED SPECIAL
optimus greenSound Level Meters for Environmental& Occupational Noise Measurements
Applications
Environmental Noise Measurements
• Environmentalnoiseimpactassessmentsovershortorlongperiods
• Environmentalnoisemonitoringoutdoorswithremotedatadownloadover3G/GPRS&GPSlocation
• Boundarynoisemeasurements&impactassessments
• MeasurementstoBS4142,ISO1996,Section61Notices
• TonalanalysisusingtoISO1996-2:2007&CirrusImprovedMethod
• Detailedanalysisusingaudiorecording
Occupational Noise Measurements
• Occupational&IndustrialHygieneNoiseEvaluations
• HearingProtectorSelectionusingHMLor1:1OctaveBandMethods
• WorkplacenoisemeasurementstoISO9612
Simple Noise Measurements
• NoiseOrdinance&CommunityNoiseAssessments
• GeneralNoiseMeasurements
Key Features
• Simpleoperationensuresthatyougetthefunctionsyouneedquickly&easily
• Simultaneousmeasurement&dataloggingofallavailableparameters
• SimultaneousA,C&ZFrequencyWeightings
• SimultaneousF,S&ITimeWeightings
• Real-time1:1&1:3OctaveBandFilters
• NR&NCvalues&curvesonscreen*
• Tonalnoiseanalysis*
• Upto28statisticalLn%values*
• Single120dBmeasurementrange
• AcousticFingerprint™audiotriggering,recording&alertsduringmeasurementsforreplayandanalysis
• VoiceTag™audionoterecording
• AuditStore™measurementverification
• Repeatingmeasurementswithmanualorautomaticcontrol
• Pause&BackErasefunctions
• HighresolutioncolourOLEDdisplayandback-litkeypadfornight-timemeasurements
• 4GBmemorycapableofstoringover10,000measurements(expandableupto32GB)
• CompatiblewithCK:670&CK:680outdoornoisemeasurementkits
• Measureupto170dBwiththeoptionalMV:200EHmicrophonesystem
Theoptimus redsoundlevelmetersusetheverylatestdigitaltechnologyandindustrialdesigntogiveyou
theidealinstrumentforOccupationalandIndustrialHygienenoisemeasurements.
cr17x/07/13/r6EN
Measure everything. Forget nothing.
The ideal solution for environmental & occupational noise
Theoptimus green soundlevelmetershavebeendesignedwitheaseofuseasthemost
importantfeaturewhichletsyougetonwithmeasuringandcontrollingthenoise.
Theinstrumentsusetheverylatestindigitaltechnologyandindustrialdesigntechniques
tomakeeverythingasclearandsimpleaspossible.Allofthefunctionsoftheinstrument
aremeasuredat the same timeso there’sno riskof choosing thewrongsetting, and
withawide120dBmeasurementspanyoudon’tneedtoworryaboutchoosingtheright
range.
Featuring a high resolution colour OLED screen and a keypad which will illuminate
automaticallyinlowlight,theoptimusinstrumentsareidealforanynoiseapplication.The
measurementdataisdisplayedinaclearandsimpleformatalongwithareal-timenoise
chartsothatyoucanseehowthenoisevarieswithtime.
Astandardoptimuscanmeasureupto140dB(A)and143dB(C)Peakwith thestandard
microphoneandpreamplifier,andupto170dBusingtheoptionalMV:200EHHighLevel
Noisemicrophonesystem.
The optimus green sound level meters are
ideal instruments for both environmental &
occupationalnoiseandwillgiveyouallofthe
informationyouneed,rightatyourfingertips.
Everymeasurementcontainsalloftheavailable
functions so there’s no risk of selecting the
wrongparameterorfunction.
Environmental Noise Measurements
For environmental noise applications, an
optimus greenistheidealinstrument.
Comprehensive measurement capability
Theoverall Leq, Lmaxandstatistical Ln%values
are measured along with a range of noise
profiles providing a complete picture of the
noiseunderinvestigation.
Real-time 1:3 Octave Bands
TheB&CvariantswillmeasureandstoreReal-
Time 1:3 octave bands from 6.3Hz to 20kHz
throughout each and every measurement,
withtheoverallvaluealongwithatimehistory
storedautomatically.
Acoustic Fingerprint triggers and audio
recording
AswellastheVoiceTagrecording,theoptimus
green instruments provide audio recording
during measurements using the Acoustic
Fingerprinttechnology.
Recordingscanbestartedeithermanuallyor
automaticallywhenuserdefined triggersare
activated.
Audiorecordingscanbestoredeither
asStudio96/32qualitywhichcanbe
usedforlateranalysis,orasStandard
16/16qualitywhichcanbeusedfor
replayandsourceidentification.
Tonal noise detection
The D variants use either the ISO
1996-2:2007SimplifiedMethodorthe
Cirrus improvedmethodtohighlight
tonalnoisein1:3octavebands.
Repeating measurements
Measurements canbe either started
manually or automatically by the
measurementcontrolfunctions.
Thisallowstheinstrumentstomakerepeated
measurementsoverlongperiodsoftime,ideal
whentheinstrumentisusedwithanoutdoor
noisemeasurementkit.
Occupational Noise & Industrial Hygiene Measurements
Aswellastheenvironmentalnoisefunctions,
theoptimus green instruments alsoprovide
a complete range of occupational noise
functions.
UK & EU Noise at Work Regulations
IfyouareworkingtotheUKControlofNoise
atWorkRegulationsortheEUPhysicalAgents
(Noise) Directive, LAeq and LCPeak values are
measured at the same timewhich allow the
LEP,d (LEX,8h) and the Peak Action Levels to be
determined. The exposure calculator also
displaysaprojectedLEP,d(LEX,8h)forthecurrent
measurement.
The LCeq-LAeq (C-A) value is also measured
whichcanbeusedtoselectPPEusingtheHML
method.
OSHA, MSHA & other regulations
If you need to meet regulations such as
OSHAHC&NC,MSHAHCor ACGIH, the two
“virtual”noisemetersintheDoseViewcanbe
quickly configured to provide youwith this
information.
Octave Band Filters for Noise Control &
Selecting Hearing Protection
The optimus green A, B & C variants also
featurereal-time1:1octavebandfilterswhich
canbeusedtoaidintheselectionofPPEand
fornoisecontrolapplications.
NR&NCcurves&valuesareshownonscreen
afterameasurement.
Outdoor Measurement Kits
NoiseTools Software
Where there is a need to measure noise levels outdoor or over long
periods, theoptimus green sound levelmeters canbeusedwith the
CK:670andCK:680outdoormeasurementkits.
Thesekitscompriseaweatherproofcasewhichcontainstheinstrument
andbatterypack(s)alongwithaninterfacetoexternalpowerandUSB.
The kits also include theMK:170 outdoormicrophonewhich provides
weatherprotectionforthemicrophonecapsuleandconnectsviaa10m
cabletothemainenclosure.
TheCK:680alsocontainsa3G/GPRSmodemandGPS locationreceiver
whichallowsthenoisemeasurementdatatobedownloadedremotelyto
theNoiseToolssoftwareviatheOptimusCloudsystem.
When used with a single battery pack, the CK:670 can power the
instrumentfor7dayswhereastheCK:680canprovidepowerfor6days.
Adding a further battery pack doubles the operating life and external
powercanbeaddedifrequired.
Datasheets for theCK:670andCK:680 contain additional details about
thesetwosystemsandcanbedownloadedfromtheCirruswebsiteat
www.cirrusresearch.co.uk/library
Standard measurement kitsCompletemeasurement kits are available for the optimus instruments
whichcontainthesoundlevelmeter,anacousticcalibrator,windshield,
cables,batteriesandaccessories.Themeasurementkitscontainallofthe
accessoriesneededtocarryoutanoisesurvey.
Detailsofthemeasurementkitsareshownonthebackofthisdatasheet.
TheNoiseToolssoftwarepackagegivesyouaquickandsimplewayto
download,analyseandreportyournoisemeasurementinformation.
The initial summary screen shows you the most commonly used
informationand,throughsimpleicons,givesyouaccesstothedetailed
measurement data. For advanced users, each and every function
measuredbytheinstrumentisavailableforreviewandanalysisandthe
datacanbeexportedforfurtheruse.
VoiceTag audio recordings can be played back for reference and are
automaticallystoredwiththemeasurementdata,andaudiorecordings
canbereplayedandanalysedin1:12OctaveBands.
Tohelpyoukeepyournoisemeasurementdataorganisedandeasyto
find, NoiseTools allows each measurement to be allocated to people,
placesandprojects.
NoiseTools is supplied free from any licensing restrictions or limits
allowingyou to install theprogramonasmanyPC’s asneededatno
additionalcost.
AuditStore™ is a new technology
thathelpsyoutoensurethatyour
noise measurement data is valid
andtrustworthy.AuditStoreallows
the user to verify measurements that have been downloaded to the
NoiseToolssoftwareagainstasecuredatastorewithintheinstrument.
Eachtimeyoumakeameasurementwithyouroptimus,aselectionofthe
overalldataisstoredintoaseparate,securememorythatisindependent
ofthemainmemorycard.
Thisdatacontainsessentialinformationaboutthemeasurementsuchas
thetime,dateandduration,theLAeq,Peak(C)andLAFmax,LA10&LA90(where
available)andtheoverloadindication.
Inaddition to thenoisemeasurementdata, informationabout the last
calibrationisalsostored.
The AuditStore data can be downloaded from the instrument when
required and then the measurements can be checked against the
AuditStore.
TheNoiseTools softwarewill check that themeasurement information
held in the main database and displayed on the screen matches the
valueswithintheAuditStoresecurememory.
NoiseToolswilldisplayverificationsymbolsiftheinformationmatches,a
uniquefeaturewhichwillbeusefulinanylegalproceedings.
AuditStore data verification
CK:670OutdoorKitshownwithoptionalCT:7Tripod
SpecificationsApplicable StandardsIEC61672-1:2002Class1orClass2GroupXIEC60651:2001Type1IorType2IIEC60804:2000Type1orType2IEC61252:1993PersonalSoundExposureMetersANSIS1.4-1983(R2006),ANSIS1.43-1997(R2007)ANSIS1.25:19911:1&1:3OctaveBandFilterstoIEC61260&ANSIS1.11-2004
MicrophoneClass1InstrumentsMK:224pre-polarizedClass2InstrumentsMK:216pre-polarized
Microphone PreamplifierMV:200RemovablePreamplifier
Total Measurement Range: 20dBto140dBRMSSingleRangeNoiseFloor:<18dB(A)Class1,<21dB(A)Class2
Frequency Weightings RMS&Peak:A,C,&ZMeasuredSimultaneously1:1OctaveBands: 31.5Hzto16kHz1:3OctaveBands: 6.3Hzto20kHz(Bandsfrom12.5Hzdisplayed, 6.3Hz,8Hz&10Hzstored&downloaded)-B&C variants AdditionalMetrics: LAeqLF(20Hzto200Hz)&LeqLF(20Hzto200Hz)
Time WeightingsFast,Slow&ImpulseMeasuredSimultaneously
DisplayHighresolutionOLEDdisplay.Ambientlightsensor&illuminatedkeypad
Memory4GB(32GBfactoryfitoption)
AuditStoreMeasurementverificationdatastoredinsecurememory
Time History Data Rates (Global settings)10ms,62.5ms,125ms,250ms,1/2sec,1sec,2sec(Userselectable)
VoiceTag Audio RecordingUpto30secondsofaudionoteswitheachmeasurement
Acoustic Fingerprint Audio RecordingOff,Manual,ThresholdTriggered,AdvancedTriggerUseroptions: StudioQuality-96kHz/32bitWAVformat Standardquality-16kHz/16bitWAVformat Pre-Triggerfunction
IntegratorsThreesimultaneous“virtual”noisemeters.Integrator1ispresettoQ3forLeqfunctions.Integrators2&3canbeconfiguredwiththefollowing:ExchangeRate:3,4or5dBThreshold: 70dBto120dB(1dBsteps)TimeWeighting:NoneorSlowCriterionLevel:70dBto120dB(1dBsteps)CriterionTime:1to12hoursin1hoursteps
Integrator Quick settingsEU,OSHAHC&OSHANC,OSHAHC&ACGIH,MSHAHC&MSHAEC,Custom1&Custom2
Ln Statistical Values14independentstatisticalLnvaluescalculatedfrom1/16thLAF7presettoL1.0,L5.0,L10.0,L50.0,L90.0,L95.0&L99.07userdefinedLnvaluesCR:172C&CR:171Callowforanadditional14Lnvalueswithindependenttimeandfrequencyweighting.
Measurement ControlMeasurementcontrolwithuserselectabledurationofmanual,1min,5min,10min,15min,30mins,1hour,LdenAutomaticSynchronisation&RepeatPauseBackErasewithuserselectableduration
DimensionsSize: 283mmx65mmx30mmWeight: 300gms/10oz
Batteries4xAAAlkaline
Battery lifeTypically12hourswithAlkalineAATypically20hourswithLithiumAANon-Rechargeable Batterylifeisdependentuponthebatterytypeandquality& screenbrightness
ConnectionsUSBTypeBtoPCAC&DCOutputviaZL:174(2xPhono,1m)Multi-pinIOforexternalpowerviaZL:171cable(2.1mmsocket)ExternalPower:5v-15vviaMultiIOsocketviaZL:171cable(2.1mmsocket)
Tripod Mount1/4”Whitworthsocket
CaseMaterial:HighImpactABS-PCwithsofttouchback&keypad
EnvironmentalTemperature: Operating-10°Cto+50°C, Storage-20°Cto+60°CHumidity: Upto95%RHNonCondensing
Electromagnetic performanceIEC61672-1:2002&IEC61672-2:2003ExceptwheremodifiedbyEN61000-6-1:2007&EN61000-6-1:2007
Language optionsEnglish,French,German,SpanishasstandardOtherlanguageoptionsmaybeavailable
Software SupportNoiseToolsDownload,Configuration&Analysissoftwaresuppliedasstandard.CompatiblewithMicrosoftWindowsXP,Vista,7&8(32bit&64bit)
Measurement Functions1
CR:1720 & CR:1710LXY,LXYMax,LXYMinLXeq,LCPeak,LZPeak,LAPeakLCeq-LAeq,LXE,LAIeqGraphofShortLAeq,LCPeakMeasurementRunTimeIntegrators2&3:TWA,Dose%,EstDose%14StatisticalLn%ValuesStored FunctionsLXYMax&TimeHistoryofLXYMaxLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqTimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqIntegrators2&3:LAVG,TWA.%DoseTimeHistoryofLAVGLnValues:14independentstatisticalvaluesAudiorecordingduringmeasurementTime,date&durationofmeasurement
CR:172A & CR:171ALXY,LXYMax,LXYMinLXeq,LCPeak,LZPeak,LAPeakLCeq-LAeq,LXE,LAIeqGraphofShortLAeq,LCPeakMeasurementRunTimeIntegrators2&3:TWA,Dose%,EstDose%Real-Time1:1OctaveBands(Graphical&Numeric)NR&NCvalues&curves14StatisticalLn%ValuesStored FunctionsLXYMax&TimeHistoryofLXYMaxLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqTimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqIntegrators2&3:LAVG,TWA.%DoseTimeHistoryofLAVG1:1OctaveBands:OverallLeq&LeqTimeHistoryforeachband,NR&NCvalues&curvesLnValues:14independentstatisticalvaluesAudiorecordingduringmeasurementTime,date&durationofmeasurement
CR:172B & CR:171BLXY,LXYMax,LXYMinLXeq,LCPeak,LZPeak,LAPeakLCeq-LAeq,LXE,LAIeqGraphofShortLAeq,LCPeakMeasurementRunTimeIntegrators2&3:TWA,Dose%,EstDose%Real-Time1:1OctaveBands(Graphical&Numeric)Real-Time1:3OctaveBands(Graphical&Numeric)NR&NCvalues&curvesLeqLF(20Hzto200Hz)14StatisticalLn%ValuesStored FunctionsLXYMax&TimeHistoryofLXYMaxLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqTimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqIntegrators2&3:LAVG,TWA.%DoseTimeHistoryofLAVG1:1&1:3OctaveBands:OverallLeq&LeqTimeHistoryforeachbandNR&NCvalues&curvesLnValues:14independentstatisticalvaluesAudiorecordingduringmeasurementTime,date&durationofmeasurement
CR:172C & CR:171CLXY,LXYMax,LXYMinLXeq,LCPeak,LZPeak,LAPeakLCeq-LAeq,LXE,LAIeqGraphofShortLAeq,LCPeakMeasurementRunTimeIntegrators2&3:TWA,Dose%,EstDose%Real-Time1:1OctaveBands(Graphical&Numeric)Real-Time1:3OctaveBands(Graphical&Numeric)TonalNoiseDetectionin1:3OctaveBandsNR&NCvalues&curvesLeqLF(20Hzto200Hz)Upto28StatisticalLn%ValuesStored FunctionsLXYMax&TimeHistoryofLXYMaxLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqTimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak,LAPeak,LAIeqIntegrators2&3:LAVG,TWA.%DoseTimeHistoryofLAVG1:1&1:3OctaveBands:OverallLeq&LeqTimeHistoryforeachbandTonalNoiseDetectionin1:3OctaveBandsNR&NCvalues&curvesLnValues:28independentstatisticalvaluesAudiorecordingduringmeasurementTime,date&durationofmeasurement
wherex=A,C,Z;y=F,S,I
OtherfunctionsmaybecalculatedbytheNoiseToolssoftwareanddisplayedondownload.
Notes1.Fordetailsofthedisplayedandstoredparameters,pleaserefertotheoptimususermanual.
Allspecifications,featuresandvaluesaretypicalandaresubjecttochangewithoutnotice.
Instrument Selection
AcousticHouseBridlingtonRoadHunmanbyNorthYorkshireYO140PHUnitedKingdom
T:08452302434(UK)+441723891655F:+441723891742E:[email protected]:www.cirrusresearch.co.uk
Function/Instrument
Class1 Class2TypeApproval
SoundLevelFunctions
Leq/PeakFunctions
TWA/DoseFunctions
DataLogging
Pause&BackErase
AuditStore
AcousticFingerprintAudioRecording
VoiceTagNote
Recording
1:1OctaveBandFilters
1:3OctaveBandFilters
NR&NCCurvesonscreen
TonalNoiseDetection
Lnvalues
SoftwareSupport
3G/GPRSModem&GPSSupport
MeasurementKit
CR:1720 CK:1720
CR:1710 PTB,LNEApplus+ CK:1710
CR:172A CK:172A
CR:171A PTB,LNEApplus+ CK:171A
CR:172B CK:172B
CR:171B PTB,LNEApplus+ CK:171B
CR:172C CK:172C
CR:171C PTB CK:171C
Standard AccessoriesTheoptimussoundlevelmetersaresupplied,asstandard,withthefollowingaccessories:UserManualCertificateofCalibrationUSBData/PowerCable
WindshieldNoiseToolsSoftwareCD
Measurement KitsTheoptimussoundlevelmetersareavailableasacompletemeasurementkitwiththefollowingaccessories:optimusSoundLevelMeterCR:514Class2orCR:515Class1Acoustic
CalibratorUA:23790mmWindshieldCK:300CarryingCaseUserManual&CertificatesofCalibrationUSBData/PowerCable&NoiseToolsSoftwareCD
ISO 9001:2008FM 531001
ISO 14001:2004EMS 552104
BRITISH SAFETY
COUNCIL
Member
cr17x/07/13/r6EN