Otomatik Emifl Sistemi KULLANIM BAKIM VSP Serisi

Upload: ngothuy

Post on 12-Jul-2019

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be

Otomatik Emifl Sistemi

KULLANIM BAKIM

VSP Serisi

Page 2: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be

EC DECLARATION OF CONFORMITYAT UYGUNLUK BEYANI

Manufacturer / ‹malatç› : MAS DAF MAK‹NA SANAY‹ A.fi.

Address / Adres : Ataflehir Bulvar› Ata Çarfl› Kat:4 No:59 34758 Ataflehir / ‹STANBUL-TÜRK‹YE

Name and address of the personauthorised to compile the technical fileTeknik Dosyay› derleyen yetkili kifli ve adresi

Ataflehir Bulvar› Ata Çarfl› Kat:4 No:59 34758Ataflehir/ ‹STANBUL - TÜRK‹YE

The undersigned Company certifies under its sole responsibility that the item of equipmentspecified below satisfies the requirements of the Machinery Directive 2006/42/EC whichis apply to it. The item of equipment identified below has been subject to internal manufacturingchecks with monitoring of the final assessment by MAS DAF MAK‹NA SANAY‹ A.fi.

Afla¤›da tan›mlanm›fl olan ürünler için Makine Emniyeti Yönetmeli¤i 2006 / 42 / AT'ninuygulanabilen gerekliliklerinin yerine getirildi¤ini ve sorumlulu¤un al›nm›fl olundu¤unubeyan ederiz.Afla¤›da tan›mlanan ürünler iç üretim kontrollerine ba¤l› olarak MAS DAF MAK‹NASANAY‹ A.fi. taraf›ndan kontrol edilmifltir.

Equipment / Ürün : SELF PRIMING UNIT / OTOMAT‹K EM‹fi S‹STEM‹

Seri / Model-Tip : VSP SERIES / VSP SER‹S‹

For Automatic Aspirator / Otomatik Emifl SistemiDirectives / Yönetmelikler2006/95/EC Low Voltage Directive / Alçak gerilim yönetmeli¤i2004/108/EC Electromagnetic Compatibility Directive / Elektromanyetik Uyumluluk Yönetmeli¤i2006/42/EC Machinery Directive / Makine Emniyeti Yönetmeli¤i

Regulations applied acc. to harmonize standards / Uygulanan Uyumlaflt›r›lm›fl StandartlarISO 12100-1/A1, ISO 12100-2/A1, EN 809/A1, EN 60204-1:2006,

Place and date of issue / Yer ve Tarih : ‹stanbul, 17.05.2011

Name and position of authorized personYetkili kiflinin ad› ve görevi

: General Manager / Genel Müdür

Signature of authorized person :Yetkili kiflinin imzas›

Page 3: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be

‹Ç‹NDEK‹LERSayfa No

Girifl 1Uygulama / Application 1Çal›flma fiekli / Function 2Otomatik Emifl Sistemi / Self Priming Unit 2Tasar›m / Design 2Sistemin Elemanlar› / Components 2Ba¤lant›lar / Connections 2Malzeme Özellikleri / Material Specification 2Elektrik Devre fiemas› / Electric Circuit Diagram 3Uyar›lar Önlemler / Warning Andaction 3Teslim fiekli / Insallation 4Teknik Özellikleri / Technical Data 4

G‹R‹fi

MAS-VSP Su halkal› vakum pompas› ile çal›flan otomatikemifl sistemidir. ‹lk hareket için emme gerektirentesisatlar için tasarlanm›flt›r. Garantili ve emniyetli emiflyapar. Her hangi bir sebeple emifl kesilirse vakumpompas› devreye girerek tekrar emifli sa¤lar.

01

MAS-VSP Automatic self-priming unit with vacuum pump,designed for the priming of centrifugal pumps wheredry running is not admissible. It guaranties a reliablepriming. If the discharge pressure fall during operation,the aspirator starts up once more for re-evacuation.

UYGULAMA: MAS-VSP emifl sistemi kat› parçaiçermeyen s›v›lar için uygundur.Kuru çal›flmas›na müsaade edilmeyen sistemler içinkullan›labilir.Gaz içeren s›v›lar için de uygundur.

APPLICATION : MAS –VSP Priming Unit is suitable forthin, clean, non- aggresive liquids free from large solidparticles and fibres.It can be used for the systems where dry running is notpermissible also for gas containing liquids.

ÇALIfiMA fiEKL‹ :Pompa motorunun çal›flt›rma butonuna (Start Butonu)bas›ld›¤›nda, e¤er pompa su ile dolu ise pompa çal›fl›r.Pompa su ile dolu de¤il ise selenoid valf aç›l›r, vakumpompas› devreye girer, oluflan vakum ile su emmeborusu içinde yükselir.Emme borusu ve pompa gövdesi tamamen su iledolunca flamand›ral› s›v› seviye rölesinin verdi¤i sinyalile motor flalteri kapan›r ve motor çal›fl›r.Pompa yeterli bas›nc› oluflturana kadar selenoid vevakum pompas› devrede kal›r.Yeterli bas›nç sa¤lan›p pompa su basmaya bafllad›ktansonra ( Pompa bas›nc› yükselince ) selenoid valf

FUNCTION: When the centrifugal pump is turned on, onlythe vacuum pump will be activated.If the pump is full of water it starts immediately.Else solenoid valve opens and vacuum pump runs. Afterevacuating has been completed, the centrifugal pump isswiched on by means of the water level switch. As soonas the centrifugal pump has build up the necessarydischarge pressure, the vacuum pump is switched off overthe pressure switch.Should the discharge pressure fall again by during pumpoperation through gas accumulation, the automatic vacuumunit starts up once more for re-evacuation . Where anautomatic shut-down system is activated (By customers

Page 4: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be

02

kapan›r, vakum pompas› durur ve pompa devreyegirmifl olur.S›v› seviye rölesinin sinyali ile motora yol verildi¤i andakoruma amaçl› zaman rölesi de devreye girer.Öngörülen süre içinde gerekli bas›nç sa¤lanamaz isesistemi durdurur. Bu zaman rölesi istendi¤inde devred›fl› b›rak›labilir.Çal›flma s›ras›nda pompa bas›nc› düflerse (Pompahava yaparsa) sistem otomatik olarak devreye girer,pompay› durdurur, vakum pompas›n› harekete geçirirve pompay› yeniden çal›flt›r›r.

control) the centrifugal pump and vacuum system shutdown automatically, if a pre-set suction time hasbeenexceeded. Should the centrifugal pump be under intakepressure when turned on, it will activated without delay.

TASARIM : Vakum pompal› otomatik emifl sistemi iyibir vakum üreticisidir. Pompa parçalar› bronzmalzemeden yap›lm›flt›r. Deniz suyu dahil bir çokak›flkana karfl› fiziksel ve kimyasal olarak dayan›kl›d›r.

Sistemin elemanlar›:• Su halkal› vakum pompas›• fiamand›ral› s›v› seviye rölesi• Servis suyu Deposu (4 lt)• Bas›nç flalteri• Su ba¤lant›s› için selenoid valf.• Pompa ç›k›fl›ndaki bas›nc› gösteren

Mano-Vakummetre

DESIGN : Water ring vacuum pump is a perfect vacuumgenerator. Body and impeller of vacuum pump are madeof bronze .The unit resistant, to a large degree, against aggresivefluids (e.g. sea water ) Components :

• Water ring vacuum pump• Float chamber with water level switch• Tank for service water (4 lt)• Pressure switch• Water line solenoid valve• Pressure gauge for discharge pressure

Terminal box

BA⁄LANTILAR : Üstteki flekilde görüldü¤ü gibi:• Vakum Hatt› ( G 1/2”) : Pompan›n emme a¤z›ndanseviye tüpünün alt ucuna• Denge Hatt› ( G 1/2”) : Pompan›n en yükseknoktas›ndan seviye tüpünün alt ucuna• Bas›nç Hatt› ( G 1/4” ) : Pompan›n basmaa¤z›ndan bas›nç rölesi ba¤lant›s›na• Egzost Hatt› ( G 1/2 “ ) : Aç›k b›rak›labilir veyaat›k su giderine ba¤lanabilir.

MALZEME ÖZELL‹KLER‹ :• V. Pompa Gövdesi Bronz ( G-CuSn10 )• V. Pompa Çark› Bronz ( G-CuSn10)• V. Pompa Mili Paslanmaz çelik• Selenoid valf Bronz• Contalar NBR

CONNECTIONS : As seen above Picture:• Vacuum Line ( G 1/2”) : From pump’s suction port tothe water level switch• Balance Line ( G 1/2”) : From pump’s highest point tothe water level switch.• Pressure Line ( G 1/4”) : From pumps discharge portto the pressure switch.• Exhaust Line ( G 1/2”) : Open to the air or waste waterdischarge

MATERIAL SPECIFICATION :• Vacuum P. Body Bronze ( G-CuSn10)• Vacuum P. Impeller Polyethylene• Vacuum P. Shaft Stainless steel• Solenoid valve Bronze• Sealing NBR

Page 5: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be

ELEKTR‹K DEVRE fiEMASI:

UYARILAR ÖNLEMLER:Gerekli pano elemanlar› ve devre ba¤lant›lar› yukar›dagösterilmifltir. Emmeyi garanti alt›na almak ve susuzçal›flmay› önlemek için motor kontrol panosuna motorçal›flt›rma kontaktörü (K01) veya büyük güçler için bir y›ld›züçgen kontaktör devresi, termik röle (F02) Start(S02) ve Stop (S01) butonlar›na ek olarak Vakum pompas›için çal›flt›rma kontaktörü (K04) ve termik rölesi (F04) biryard›mc› kontaktör (K02), bir zaman rölesi (K03) ve birseçme anahtar› (S03) ilavesi gereklidir.VSP emifl sisteminin ba¤lant› flemas› ise fleklin alt›ndagörülmektedir. Motor kontrol panosu ile VSP aras›nda5 iletkenli bir ara kablo bulunmal›d›r.* Bas›nç Rölesinin ayar› (P1): Bas›nç rölesinin start

bas›nc› VSP uygulanan pompan›n çal›flma bas›nc›na uygun olmal›d›r. Rölenin normalde kapal› devresi kullan›lacakt›r. Açma bas›nc› pompa çal›flma bas›nc›ndanen az 1 Bar küçük olmal›d›r.

* Zaman Rölesinin ayar› (K03): Bu rölenin süresi motorkontaktörünün çekmesi ile pompan›n bas›nç üretmesiaras›nda geçen emniyetli zamand›r ( 5~10 sn olabilir) Y›ld›z - üçgen yolvermeli motorlar için y›ld›zda geçen zamandan uzun olmal›d›r. (y›ld›z - üçgen zaman rölesisüresinden 2 sn daha uzun olabilir.)

* Ayar de¤erleri ön çal›flt›rmada kontrol edilmeli ve gereklidüzeltmeler yap›lmal›d›r.

* Ayarlanan de¤erlerde emme sa¤lanamaz ise:1- Emme borusunu, varsa emme vanas›n› ve kollektörü

kontrol ediniz.2- Servis suyu deposunda yeterli su oldu¤unu

kontrol ediniz.3- Vakum pompas›n›n dönüfl yönünü ve selenoidi

kontrol ediniz.4- Egzost borusundan yeterli ç›k›fl olup olmad›¤›n›

kontrol ediniz.5- Emme ifllemi s›ras›nda Mano- Vakummetre negatif

de¤er (Vakum) göstermeli, pompa çal›flt›ktan sonra bas›nca geçmelidir. Kontrol ediniz.

ELECTRICAL CIRCUIT DIAGRAM:

WARNINGS AND ACTION :Necessary panel elements and circuits are shown onabove diagram .To guarantee priming condi-tions and toprevent dry operation, one Auxiliary contactor (K02), onetime relay (K03), one selector switch (S03) and a contactor(K04) and thermal relay (F04) for vacuum pump's motorshould be also placed to the control panel in additon tomotor starting contactor (K01) or star-delta connectioncircuit for bigger motor powers, thermal relay (F02), Start(S02) and Stop (S01) buttons.The circuit diagram of VSPpriming unit can be seen under the drawing.There is a cable having 5 conductors between motorcontrol panel and VSP.* Adjustment of Pressure Relay ( P1 ) : Start Pressure

of the relay should be suitable for the pump's workingpressure. The closed contact of the relay will be used.Opening pressure should be at least 1 bar smaller thanthe pump's working pressure.

* Adjustment of Time Relay ( K03 ): Time of this relayis the safety time between motor's contactor start andpump's start pressurising. (app. 5-10 sc.) For star-deltaconnection motors, time should be longer than star connection (app. 2 seconds more)

* Set values should be re-checked during pre-operationand necessary changes should be done if required.

* In case there is a problem with priming at the settledvalues:

1- Check the suction pipe, and check the suction valveand collector if any

2- Check the service water tank, if there is enough waterin it.

3- Check direction of rotation of vacuum pump.4- Check if there is enough discharge from the exhaust

pipe.5- During priming, manometer should indicate negative

value (vacuum), and should be pressurised after the pump starts operation.

03

Page 6: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be

04

TESL‹M fiEKL‹ :

MAS - VSP Otomatik emifl sistemi :1- Yere veya duvara monte edilebilecek ayr› bir ünite olarak

veya,2- Pompa üzerine monte edilmifl olarak çal›flmaya haz›r

flekilde teslim edilebilir.

MAS-VSP unitesi, Havas› boflalt›lacak hacmin en yükseknoktas›ndan daha yukar›ya monte edilmelidir.Motor kontrol panosu içindeki devre ve elemanlar›, buradakidevre flemas›na uygun olarak kullan›c› taraf›ndan teminedilecektir.

BOYUTLAR:

INSTALLATION :

MAS - VSP automatic priming system is delivered:1- As a separate unit suitable to mounting at a wall or

ground or,2- As a ready to install unit mounted on the main pump

MAS - VSP unit is to be fitted at the highest point to beevacuated .Above mentioned parts and circuits on the motor controlpanel will be supplied by the end user according to theenclosed circuit diagram.

DIMENSIONS:

TEKN‹K ÖZELL‹KLER‹:* ‹flletme gerilimi 24 V - 50/60 Hz.* Koruma s›n›f› IP 54* Motor Gücü 1.5 KW* Seviye rölesi gücü Max 100 VA* Nominal Bas›nç PN 10* Emme kapasitesi 300 Nl/dak* Max. Emme Derinli¤i 6 m.* Servis Suyu Deposu 4 lt

TECHNICAL DATA:* Operating Voltage 24 V - 50/60 Hz* Protection class IP 54* Motor Power 1.5 KW* Switching capacity Max 100 VA* Nominal pressure PN 10* Suction capacity 300 Nl / min* Max. Suction head 6 m.* Service Water Tank 4 lt

Page 7: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be
Page 8: Otomatik Emifl Sistemi VSP Serisi - Mas Grup - Pompa ... · Kontrol ediniz. ELECTRICAL CIRCUIT DIAGRAM: WARNINGS AND ACTION : ... For star-delta connection motors, time should be

Fabrika / Merkez Servis

www.masgrup.com [email protected]