GRUNDFOS DATA BOOKLET Oxiperm OCD-164 30 to 2000 g/h Preparation of chlorine dioxide from diluted solutions

Upload: others

Post on 23-Mar-2020

33 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

GRUNDFOS DATA BOOKLET

Oxiperm OCD-16430 to 2000 g/h

Preparation of chlorine dioxide from diluted solutions

Page 2: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Table of contents

2

Oxiperm OCD-164

1. General 3Oxiperm OCD-164 3Applications 3No chance for pathogens 3

2. Construction 4Oxiperm OCD-164 with solenoid valve 4Oxiperm OCD-164 for batch operation 4Oxiperm OCD-164 with internal bypass pump 4

3. Technical data 5Mechanical, electrical and electronic data 5Capacity and consumption data 6

4. Dimensions 7Standard system 7Front installation system OCD-164-xxxDFI 7

5. Accessories and maintenance kits 8Accessories 8Maintenance kits 8

6. Grundfos Product Center 9

Page 3: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Gen

eral

Oxiperm OCD-164 1

1. General

Oxiperm OCD-164Oxiperm OCD-164 uses diluted 9 % HCl solution and 7.5 % NaClO2 solution to generate 30 to 2000 g/h of chlorine dioxide.

Precision and process stability• High efficiency and user-friendly ergonomics• State-of-the-art sensors and electronics as well as

unique calibration technology provide high precision and process reliability.

• The interaction of precise dosing technology, perfect mixture of components and complete chemical reaction within a short time keep your costs at a low level permanently.

Dual controlLEDs in a clearly arranged flow scheme allow possible errors to be identified quickly and precisely. In addition, all operating states and messages are shown in the plain-text display.

Compact design and functionAll components that require regular maintenance are very easy to access.

Remote communicationOptionally, Oxiperm OCD-164 can be connected to higher-level integration systems and process control systems via bus interface.

ApplicationsUsually, disinfection is the first step of pathogen reduction, in order to continue operating a drinking water installation. An ideal means of ensuring the sterility of drinking water is to use chlorine dioxide as adisinfectant. Chlorine dioxide is highly effective againstall types of germs and has a long dwell time in the tubing system, which means it disinfects even without re-dosing. The big advantage of chlorine dioxide over other disinfectants is its effectiveness against biofilms. It destroys the existing biofilm, thus removing the breeding ground for microorganisms, and prevents it from building up again.Ideal application areas for Oxiperm include combating germs and pathogens, such as legionella in building installations, disinfecting cooling water systems, and disinfecting drinking water in water plants or industrial processes.Chlorine dioxide is often used in the food and beverage industry for disinfection of process water or for CIP and bottle washing because it doesn’t change the taste or smell of the treated water.

RemarkLegislation on the use of disinfection products in water treatment applications is country-specific. Please contact your local Grundfos sales office for further details on the on the use of our products in your application and area.

No chance for pathogensLegionella are rod-shaped bacteria that enter drinking water systems and start to reproduce. Especially in temperatures between +30 °C and +40 °C legionella reproduce quickly. The bacteria can enter the lungs when a person inhales aerosols containing legionella when showering. They can cause a life-threatening form of pneumonia known as legionellosis. The ideal breeding ground for legionella in drinking water systems can be found in biofilm, a slimy layer on the inside of water pipes, where other pathogens also build up and reproduce. Legionella also establish themselves in amoebae, which offer them protection against conventional disinfection methods. Using Oxiperm ensures reliable removal of the biofilm with all pathogens and legionella present in piping and prevents reinfestation. For decontamination, disinfection represents only a part of the accompanying measures, such as constructional modifications.

Effectiveness diagram

Fig. 1 Effectiveness diagram: hypochlorous acid (HClO) compared with chlorine dioxide (ClO2)

TM06

351

4 06

15

100

80

60

40

20

0

Res

idua

l ger

ms

[%] pH > 7.5

Residual germs with HClO

Residual germs with ClO2

0.02 0.04 0.06

Concentration of disinfectant [mg/l]

3

Page 4: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Construction

4

Oxiperm OCD-1642

2. Construction

Oxiperm OCD-164 with solenoid valve

Fig. 2 Oxiperm OCD-164 with internal solenoid valve

Oxiperm OCD-164 for batch operation

Fig. 3 Oxiperm OCD-164 for batch operation and solenoid valve

Oxiperm OCD-164 with internal bypass pump

Fig. 4 Oxiperm OCD-164 with internal bypass pump

Legend

Note: For protection of the drinking water supply, the customer has to provide a pipe disconnector (to DVGW, W624).

TM06

278

0 46

14TM

06 2

781

4614

67

3

1

10

54

2

9

13

12

HClNaClO2

HClNaClO2ClO2

11

36

1

10

54

9

2

TM06

278

2 46

14

1 Oxiperm OCD-164 electronics 2 Connection for bypass water input 3 Connection for the ClO2 solution line output to the injection unit 4 Suction line for the HCl dosing pump 5 Suction line for NaClO2 dosing pump 6 Shut-off valve (by customer) 7 Sample extraction (by customer)

8 Check valve (by customer), for operation with an internal bypass pump

9 Shut-off valve for bypass water extraction (by customer)10 Exhaust system for supporting rack (option)11 Batch tank with level monitoring (option), for batch operation

12 Pressure loading valves (by customer) for system counterpressure < 1 bar

13 Inductive flowmeter 4-20 mA or contact water meter for proportional control of the system

8 139

1

67

10

54

2

3

HClNaClO2

Page 5: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Tech

nica

l dat

a

Oxiperm OCD-164 3

3. Technical data

Mechanical, electrical and electronic data

Note: The water meter has to be designed in a way that the number of input pulses for the control is between 1-45 pulses/second.

Mechanical data

Adjustment of the preparation capacity Manual by menu-controlled operator prompting, automatic by input signals

Protection levels• IP65 Electronics, dosing pumps, solenoid valve (option), flowmeter• IP44 Bypass pump (option)• IP67 Dosing controller

Admissible concentration of chemicals• HCl 9 percent by weight• NaClO2 7.5 percent by weight

Admissible temperatures

• Ambient temperature: +5 to +40 °C• Operation water temperature: +2 to +30 °C• Chemicals temperature: +2 to +30 °C • Storage and transport temperature: 0 to +50 °C

Admissible relative air humidity Max. 80 %, not condensing

Connections• Dilution water inlet: PVC pipe DN 20 / 3/4" NPT male thread (option)• ClO2 solution: PVC pipe DN 20 / 3/4" NPT male thread (option)

Safety equipment Parallel monitoring of the capacity via dosing controller, and internal Hall sensor signal for all dosing pumps

Materials

Supporting rack PPFastening Stainless steelReactor PVC, iron steel and stainless steel, paintedPost mixer PVC greyPipes PVC greyGaskets FPM/PTFE

Electrical and electronic data

Mains voltage 230 V / 50 Hz or 115 V / 60 Hz

Power consumption• Up to 220 g/h: Approx. 300 VA• From 350 g/h: Approx. 650 VA

Control

• PLC• 4-line plain-text display• Menu-controlled operator prompting• Flow scheme with LED display showing mode and error signal• Operating languages: German, English, French, Spanish, Italian

Analog inputs 0(4) - 20 mA input or free configuration, load 50 Ohm

Digital inputs

• Contact water meter, 1-45 pulses/second for control• MIN contact for main water• Remote On/Off• Error gas warning unit• Batch tank ClO2: overflow, MAX, MIN, dry run

Analog outputs 0(4) - 20 mA input or free configuration, max. load 500 Ohm

Potential-free outputsmax. charge 250 V, 6 A, max. 550 VA

• Error messages• Pre-alert: chemicals empty • Dry run ClO2 batch tank• Automatic/manual operation, max. load 250 V, 6 A, max. 550 VA

Optional bus systems • Modbus (RS 232 / RS 485)

5

Page 6: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Technical data

6

Oxiperm OCD-1643

Capacity and consumption dataOxiperm OCD 164 systems are also available as front installation variants. The designation of the front installation variants is Oxiperm 164-xxxDFI.

1 With max. preparation capacity, shortened reaction time.2 With admission pressure 2 bar higher than the pressure at the injection unit.3 In batch operation the concentration is freely adjustable between 0.5 and 3.3 g/l.

Between 2 and 3.3 g/l the system operates at full capacity. From 2 down to 0.5 g/l the system reduces the capacity continuously, because the dosing quantity of the chemical components is regulated if the bypass water quantity is set to constant.

VersionsCheck valve (reactor)• System counterpressure less than 3 bar• System counterpressure more than 3 barSystem completely for wall mounting

Options• With solenoid valve, with / without exhaust system• For batch operation, with / without exhaust system• With internal bypass pump, with / without exhaust

system• With external centrifugal pump (provided by the

customer), with / without exhaust system• System for wall mounting, reactor on back side• System for wall mounting, all components on front

side (DFI), only up to 220 g/h

ClO2 preparation capacity

Max. operation pressure pmax

Consumption of components

Consumption of bypass water(input pressure < pmax)

WeightOxiperm OCD50 Hz 60 Hz1 HCl NaClO2

Continuous operation2 Batch operation3

[g/h] [l/h] [bar] [bar] [l/h] [l/h] [l/h] 0.5 g/l[l/h]

2.0 g/l[l/h]

3.3 g/l[l/h] [kg]

30 421 10 10 0.7 0.7 420 66 14 7.7 33 164-030D (DFI)120 426 9 6 2.9 2.9 420 220 55 31 34 164-120D (DFI)220 430 7 7 5.2 5.2 420 400 100 56 34 164-220D (DFI)350 437 9 9 8.3 8.3 420 640 160 89 57 164-350D700 933 9 9 16.5 16.5 900 1280 320 179 62 164-700D

1000 948 9 9 24 24 900 1800 450 258 66 164-1000D1500 970 9 9 35 35 900 2720 680 383 76 164-1500D2000 996 9 6 48 48 900 3600 900 517 82 164-2000D

Page 7: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Dim

ensi

ons

Oxiperm OCD-164 4

4. Dimensions

Standard system

Fig. 5 Standard system, Oxiperm OCD-164

Front installation system OCD-164-xxxDFI

Fig. 6 Front installation system, Oxiperm OCD-164-xxxDFI

Option: NPT 3/4"

TM06

278

9 46

14

KL

GH

AB

FE

CC1

CC2

M

NaClO2 HCl

TM06

279

0 46

14

KL

AB

FE

C2

D

C1

C

M

NaClO2 HCl

A B C D E F G H K L M ConnectionsC1 and C2 Oxiperm OCD

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]700 650 40 - 800 760 230 148 148 410 9 DN 20 164-030D700 650 40 - 800 760 230 148 148 410 9 DN 20 164-120D700 650 40 - 800 760 230 148 148 410 9 DN 20 164-220D950 790 45 36 900 710 - - 102 213 10 DN 20 164-030DFI950 790 45 36 900 710 - - 102 213 10 DN 20 164-120DFI950 790 45 36 900 710 - - 102 213 10 DN 20 164-220DFI760 700 70 - 1010 970 268 135 181 470 11 DN 20 164-350D760 700 70 - 1010 970 268 135 181 470 11 DN 20 164-700D760 700 70 - 1010 970 268 135 181 470 11 DN 20 164-1000D760 700 70 - 1300 1260 268 135 181 470 11 DN 20 164-1500D760 700 70 - 1300 1260 268 135 181 470 11 DN 20 164-2000D

7

Page 8: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Accessories and m

aintenance kits

8

Oxiperm OCD-1645

5. Accessories and maintenance kits

Accessories

Suction line systems• 2 suction lines with 2 tank covers• with empty signal and pre-alert

Water extraction

Injection unit

Maintenance kits

Tank size[l]

Tank opening diameter[mm]

Suction line[m]

30 45-46 1.3, 2.5, 5 60 45-46 / 57 - 58.5 1.3, 2.5, 5200 56 2.5, 5

Material Connection Oxiperm system

Connection water supply

Product number

PVC DN 20 G1 96727276

Material Connection Oxiperm system

Connection injection unit

Product number

PVC DN 20 R1" 96696417

Oxiperm OCDSystem pressure

Less than 3 bar More than 3 bar164-030D/120D 96689088 96689089

164-220D 96689109 96689110 164-350D 96689090 96689091 164-700D 96689092 96689093164-1000D 96689094 96689095164-1500D 96689096 96689097164-2000D 96689098 96689099

Page 9: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

Gru

ndfo

s Pr

oduc

t Cen

ter

9

Oxiperm OCD-164 6

6. Grundfos Product Center

Subject to alterations.

All the information you need in one place DownloadsPerformance curves, technical specifications, pictures, dimensional drawings, motor curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts. The Product Center displays any recent and saved items - including complete projects - right on the main page.

On the product pages, you can download installation and operating instructions, data booklets, service instructions, etc. in PDF format.

SIZING enables you to size a pump based on entered data and selection choices.

Online search and sizing tool to help you make the right choice.

http://product-selection.grundfos.com

REPLACEMENT enables you to find a replacement product.Search results will include information on

• the lowest purchase price• the lowest energy consumption• the lowest total life cycle cost.

CATALOGUE gives you access to the Grundfos product catalogue.

LIQUIDS enables you to find pumps designed for aggressive, flammable or other special liquids.

Page 10: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

10

Page 11: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

11

Page 12: Oxiperm OCD-164 - Grundfosnet.grundfos.com/Appl/ccmsservices/public/... · Oxiperm OCD-164 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for pathogens 3 2. Construction

GRUNDFOS A/S DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00www.grundfos.com

91834789 0815

ECM: 1157661 The

nam

e G

rund

fos,

the

Gru

ndfo

s lo

go, a

nd b

e th

ink

inno

vate

are

regi

ster

ed tr

adem

arks

ow

ned

by G

rund

fos

Hol

ding

A/S

or G

rund

fos

A/S

, Den

mar

k. A

ll rig

hts

rese

rved

wor

ldw

ide.

© C

opyr

ight

Gru

ndfo

s H

oldi

ng A

/S