pa-9 power analyzer

33
Pa-9 Power Analyzer V 1.0 1/14/2000

Upload: brady-rogers

Post on 02-Jan-2016

80 views

Category:

Documents


0 download

DESCRIPTION

Pa-9 Power Analyzer. V 1.0 1/14/2000. OBJECTIVES. Use The Latest Technology To Deliver Highest Performance At Lowest Cost. One of the most powerful DSP’s. Co-microprocessor. Low Cost Digital Camera Hi-Density Memory. Low Cost/High Performance Graphical Display. Delay Obsolescence. - PowerPoint PPT Presentation

TRANSCRIPT

Pa-9 Power Analyzer

V 1.01/14/2000

2

OBJECTIVES

Use The Latest Technology To Deliver Highest Performance At Lowest Cost.One of the most powerful DSP’s.Co-microprocessor.Low Cost Digital Camera Hi-Density Memory.Low Cost/High Performance Graphical

Display. Delay Obsolescence.Worldwide Product.

3

Result: pa-9 Power Analyzer Evolved from:

15+ Years Experience With Utilities Monitoring And Power Quality Measurement Needs

Listening To Suggestions From Our 600+ Customers and Experience From Our Very Successful Products like the pa-7 Power Analyzer (1600 units installed).

Our Goal: Extend To The Industrial Market Our Reputation

Earned Through 15 Years of Service/Reliability To The Utility Market.

4

Light Rugged polypropylene

Case (12.5lbs or 5.7Kg)

LockableHasps

5 Current Channels

Optional Auxiliary AC PowerInput (90-600vac/dc)

4 Voltage Channels

OptionalExternal RS232 Port

Optional Modem

5

KEY FEATURES

Simplified Instruction

Sheet

Home Key

Backlit Graphic Display

Mouse Type Navigation

System

DB9 RS232 PortReal Time Display Key

6

KEY FEATURES

4 V (Differential)/5 Current Channels Range: Voltage 600V AC or DC Current Based on CT Most Configurations Supported for Power Measurements Immediate Local Info on Graphical Display Powered from Phase A Voltage (90-600v AC ,or 110-600v DC) FLASH PROM & Non-Volatile Data Memory 256/Cycle Sample Rate (TRMS through 63rd Harmonic) Memory Up to 12 MB And Data Transfer Up to 115KB Sub-Cycle Event Capture to 65 Microsecond Events 3 Packages – Portable, Wall Mount, Rack Mount

7

KEY FEATURES

4 Simultaneous Recordings

RMS (Long Term Trend)

Out of Limits Log (for RMS Value)

Waveform

Power Flow Parameters

8

RMS Recording Parameters to consider

Sample Rate (Fixed at 256/cycle) Response Time (or Integration Time) User Settable

To 1 cycle or longer. Cycle by Cycle Recording Possible.

Storage IntervalUser Settable 1 To cycle 4 Hours. Save Min RMS, Max RMS, Overall RMS per Storage Interval.

Technique Conserves Memory and Guarantees Capture of Lowest & Highest Signal Values per Storage Interval.

9

Stored True RMS Voltage / Current

Pa-9 can display: MIN, MAX, and TRMS values

for all channels for entire test. (Press HOME, select “Stored Data, RMS Interval”)

Trending graphs of any parameter right on pa-9. (ex. VA MIN trended over entire test)

Ms-pa9W software Tabular Report (right) MIN, MAX, & RMS Reported

at every storage interval. Data for trending graphs

with scan line click and drag zooming

(next)

10

Notice the 5V dip (blue) when the large load turned on (red).

Metrosonics pa-9

Scan Line, you can move to provide values

in window

11

Out-Of-Limits Log

User Sets Following Limits By ChannelHigh/Low RMS Limits (V & I)Sub-Cycle Impulse Magnitude. THD%

Recorder Captures All Events Outside of User Preset Limits And Logs Them With Duration In Out-Of- Limits Log.

12

Stored Data:Event / Out of Limits Data

Out of Limits- While recording, continuously monitors for excedances of user defined limits for upper & lower V/I, sub-cycle (65uS), and THD. Monitors all connected channels, for analysis between load /

source side. Large event memory up to 1,000 events! Exact reporting of MIN, MAX, and RMS during event timeframe. Reports events as short as 65uSeconds.

13

Waveform Capture

Waveforms Are Captured WithEvent TriggerTime TriggerManual Trigger from Front Panel

User Specifies Number of Pre-Trigger Cycles (Max 2) and Number of Post-Trigger Cycles (Max 99) To Capture.

14

Waveform Display

15

Ms-pa9W waveform chart triggered on loss of voltage.

Metrosonics pa-9

16

Applications for pa-9:Waveform Capture - Motor Inrush

Waveform capture triggered on Rising Current Three phase chiller

start-up inrush. Display all captured

cycles on one screen. (Inrush decay envelop)

Same click and drag zoom and scan line features.

17

Demand Recording

User Specifies Demand Interval, Fixed Or

Sliding Window, Configuration (Wye,

Delta etc).

All Power Parameters Are Recorded (KW,

KVAR, KVA, pf, dpf etc).

Power Data Can Be Recorded As Fast As

Every 6 Cycles (1 Cycle In Future).

18

Stored Data:Demand Data (with power flow option)

ms-pa9W Software allows: Printing and exporting of text data reported every storage

interval Trending graphs with click and zoom capabilities Scan line reporting and vector diagrams (next)

19

Demand Graph Demand Graph with scan line with scan line feature and feature and vector diagram.vector diagram.

Metrosonics pa-9

20

Real Time Harmonic Analysis

FFT Done Every 6 Cycles.

Harmonic Analysis And Direction Of

Harmonic Power Flow Presented On

Display.

Generally A Good Indicator Of

Source of Harmonics

21

Here we see we have nearly 75 Amps of Neutral Current, of which 45.9 Amps are comprised of the 3rd harmonic. (bar graph superimposed allows viewing to 63rd)

Harmonic Analysis In Software

22

Software

32-bit Software Package ms-pa9W Compatible with Win 95/98/NTGenerates Graphs/ReportsPQDIF Support Coming IEC Flicker (Coming)

23

Future Software Enhancements (4Q2000)

Harmonic Trending

Total Demand Distortion (TDD%) Trending

CBEMA Scatter Diagram

Single Software Package for Multiple Models

Report Generator

24

Hardware: User Interface

RS-232 serial communications (to 115 KBAUD)

Graphical display: View real time and stored data

(text and graphical)

4 MB base memory (expandable to 8 or 12MB)

Large tactile keypad for easy operation even with gloves on.

25

Hardware: Packaging

Packaging: Rugged enclosure:

High impact Smaller package (13x10x6) NEMA 4X Weatherproof Lockable hasps Protective handles on input

connector side.

Lightweight (15 lbs./ 6.8 Kg.) Wide temperature range (-20C

to +50C)

26

Hardware: Voltage Channels 4 Voltage Channels

150/600VAC + DC auto-

ranging. Safety banana jack

inputs Right angle prevents

accidental pull out Unfused probes

standard, fused probes optional.

Resolution .1% full scale.

Accuracy .25% rdg + .05% full scale.

27

Hardware: Current Channels

5 Current Channels Resolution .1% Full Scale Accuracy .25% rdg +.05%

range + probe accuracy. Current probes

Cp-6000CE - 600/6000A Powered from pa-9!! 1% reading accuracy!

1000A, 100A, 20A CT’s Avlbl Adapter cable mates most

Metrosonics ct’s to pa-9 On-site CT Selection

Directly From pa-9 Without Reprogramming.

28

Hardware: Power Supply

90-600VAC or 110-600VDC Operation. Power From V(A channel) standard

No separate regulated 120VAC power source required Optional (independent) AC power input. Optional DC power input. (+12VDC)

Internal Sealed Lead Acid Battery. Outage ride through time 15 minutes. Non-Volatile Memory Data Retention.

External Ground Lug.

29

Summary: Unique Features No Other Single Instrument Combines The Following

Features 9 Channels. Measure AC or DC Voltage. Simultaneously Record RMS/Power/Waveforms. Capture Events As Fast As 65 Microseconds. Capture 2 Pre-trigger Cycles & Many Post-trigger. 256 Sample/Cycle Rate + FFT Every Few Cycles. Trigger On Current As Well As Voltage. Measure Phase A Frequency. Display Direction of Harmonic Power Flow. Store 60 setups in the Recorder (Field Selectable). Power Off Phase A Voltage With ac OR dc Voltage. Wide Industrial Temperature Range. Portable, Wall Mount, Rack Mount Packaging.

30

Key Front Panel Displays

Store Up To 60 Field

Selectable Setups.

Select CT’s In The Field

View Event Log On Site

31

Planned Developments

Next Generation Software. Trend More Items (Harmonics, Freq.), State Compliance With Standards (CBEMA, IEEE 519, IEEE 1159).

Networking for Fixed Units. Internet Connectivity.

Expand Product Line.

Keep Listening To Our Customers!

32

Pa-9 Starter Kit Sk-pa9-01 - Starter kit includes includes:

pa-9, w/ 12 MB internal memory pa-9-PF Power Flow Option ms-pa9W - 32 bit Windows software ca-pa9-11- kit of 4 (unfused) voltage cables with alligator

clips and a set of neutral jumper cables ca-pa9 charging cable ca-rs232 - db9 communications cable (3) cp-6000CE 600/6000 Amp AEMC Flexible current

probes (powered from pa-9) SC-PA9 soft sided carry case 1 Year Warranty

33

Thank you for the opportunity of being

Able to Show You The Capabilities of

This Remarkable Instrument!!

Have A Great Day