page 2 introduction physiological aspects monitoring requirements
TRANSCRIPT
![Page 1: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/1.jpg)
![Page 2: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/2.jpg)
Page 2
IntroductionIntroduction
Physiological Aspects Physiological Aspects
Monitoring RequirementsMonitoring Requirements
![Page 3: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/3.jpg)
![Page 4: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/4.jpg)
Page 4
Thoracic anesthesia is challengingThoracic anesthesia is challenging
Patient Patient Procedure Procedure
![Page 5: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/5.jpg)
![Page 6: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/6.jpg)
Page 6
““V" - ventilation V" - ventilation - the air which reaches the lungs
"Q" - perfusion "Q" - perfusion - the blood which reaches the lungs
Normal V is 4 L of air per minute.
Normal Q is 5L of blood per minute.
So Normal V/Q ratio is 4/5 or 0.8. Normal V/Q ratio is 4/5 or 0.8.
When the V/Q is higher than 0.8, it means ventilation exceeds perfusion.
When the V/Q is < 0.8, there is a VQ mismatch caused by poor ventilation
![Page 7: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/7.jpg)
Page 7
An area with no ventilation (and thus a V/Q of zero) is termed "shunt." "shunt."
An area with no perfusion (and thus a V/Q of infinity) is termed “dead space”“dead space”
![Page 8: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/8.jpg)
Page 8
A change in volume divided by a change in transpulmonary pressure.
(CL = ΔV / ΔPL)(CL = ΔV / ΔPL)
A typical value of compliance is 200 ml/cm H20
![Page 9: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/9.jpg)
![Page 10: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/10.jpg)
Page 10
![Page 11: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/11.jpg)
Page 11 Pulmonary blood flow distribution relative to the Pulmonary blood flow distribution relative to the alveolar pressurealveolar pressure
Ven
tilation
Ven
tilation
![Page 12: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/12.jpg)
Page 12
Patient awake spontaneously breathing
The dependent lung is betterVentilated than the
Nondependent lung,˙V/˙ Q still is well matched.
![Page 13: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/13.jpg)
Page 13
![Page 14: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/14.jpg)
Page 14
![Page 15: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/15.jpg)
Page 15
![Page 16: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/16.jpg)
Page 16
The principle physiologic change of Oprinciple physiologic change of OLV is the redistribution of lung perfusion between the ventilated (dependent) and blocked (nondependent) lung
Many factors contribute to the lung perfusion, the major determinants of them are hypoxic pulmonary hypoxic pulmonary vasoconstriction, HPV and gravity. vasoconstriction, HPV and gravity.
![Page 17: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/17.jpg)
Page 17
HPV is a widely conserved, homeostatic, vasomotor response of precapillary smooth muscle in the PAs to alveolar hypoxia. HPV mediates ˙V/˙Q matching and, by reducing shunt fraction, optimizes systemic pO2.
![Page 18: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/18.jpg)
Page 18
Reduces the surface area available for gas exchangeReduces the surface area available for gas exchange
Reduced arterial oxygen tensionReduced arterial oxygen tension
Maintaining oxygenationMaintaining oxygenation and and
elimination of carbon dioxide elimination of carbon dioxide is the greatest challengeis the greatest challenge
![Page 19: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/19.jpg)
Page 19
![Page 20: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/20.jpg)
Page 20
Use of Monitoring to Detect and Diagnose Use of Monitoring to Detect and Diagnose Intraoperative EventsIntraoperative Events
RespirationRespiration
OxygenationOxygenation
VentilationVentilation
Cardiovascular functionCardiovascular function
![Page 21: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/21.jpg)
Page 21
![Page 22: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/22.jpg)
Page 22
![Page 23: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/23.jpg)
Page 23
![Page 24: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/24.jpg)
Page 24
ElectrocardiographyElectrocardiography
Arrhythmia, ischemia
Intraarterial catheterIntraarterial catheter
Hypotension or hypertension
Arterial compression
![Page 25: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/25.jpg)
Page 25
Pulmonary artery catheterPulmonary artery catheter
Pulmonary hypertension, filling pressures, assess
cardiac performance
SvO2SvO2
Adequacy of cardiac output
![Page 26: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/26.jpg)
Page 26
Transesophageal EchocardiographyTransesophageal Echocardiography
Ischemia, volume status, right ventricular dysfunction
![Page 27: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/27.jpg)
Page 27
Failure to check the equipment properlyFailure to check the equipment properly before induction of anesthesia isbefore induction of anesthesia is
responsible for 22% of theresponsible for 22% of the critical incidents that occur during anesthesiacritical incidents that occur during anesthesia
![Page 28: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/28.jpg)
Page 28
Healthy patients no special intraopertive conditionsHealthy patients no special intraopertive conditions
Sick patients special intraopertive conditionsSick patients special intraopertive conditions
Tier ITier I
ProcedureProcedure PatientPatient
![Page 29: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/29.jpg)
Page 29
Gas exchange
Airway mechanics
Endotracheal tube position
PA pressures
Cardiovascul-ar status
Color of tissues and shed blood Spo2, PETCO2
Feel of the breathing bag, stethoscope,PIP, PETCO2
EBBS Ballotable balloon in SSN, FOB afterplaced in LDP
Not measured NIBP, pulse oximeter waveform, ECG, PETco2esophageal stethoscope,± CVP, ± invasive arterialpressure monitoring
![Page 30: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/30.jpg)
Page 30
![Page 31: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/31.jpg)
Page 31
Healthy patients no special intraopertive conditionsHealthy patients no special intraopertive conditions
Sick patients special intraopertive conditionsSick patients special intraopertive conditions
Tier IITier II
ProcedureProcedure PatientPatient
![Page 32: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/32.jpg)
Page 32
Healthy patients no special intraopertive conditionsHealthy patients no special intraopertive conditions
Sick patients special intraopertive conditionsSick patients special intraopertive conditions
Tier IITier II
ProcedureProcedure PatientPatient
![Page 33: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/33.jpg)
Page 33
Gas exchange
Airway mechanics
Endotracheal tube position
PA pressures
Cardiovascul-ar status
As above plus frequent ABG studies
As above plus spirometry. Individual and whole-lungcompliance
FOB to verify tube position while in supine position, as well as in the LDP
Measure Ppa if lobectomy or lung resection
As above, plus invasive arterial pressure monitoring, + CVP, + PA catheter (if poor EF, PA,HTN), ± TEE
![Page 34: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/34.jpg)
Page 34
SpirometrySpirometry is a non-invasive monitor device which measures volume, pressure and flow volume, pressure and flow in the airway.
These measurements may be used to construct :
a pressure-volume curve (PV) and
a flow-volume curve (FV).
The constructed curves will give important information about the peri-operative respiratory function.peri-operative respiratory function.
![Page 35: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/35.jpg)
Page 35
Healthy patients no special intraopertive conditionsHealthy patients no special intraopertive conditions
Sick patients special intraopertive conditionsSick patients special intraopertive conditions
Tier IIITier III
ProcedureProcedure PatientPatient
![Page 36: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/36.jpg)
Page 36
Gas exchange
Airway mechanics
Endotracheal tube position
PA pressures
Cardiovascul-ar status
As above plus Qs/Qt, VD/Vtfrequent VBGs
As above plus airway resistance
As above plus frequent rechecksto verify position
Measure PA ,Q , PVR , SVR, Dao2 –Dvo2
As above plus PA , TEE
![Page 37: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/37.jpg)
Page 37
![Page 38: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/38.jpg)
Page 38
Measured values:Measured values:
CVPCVP: 1-6 mm Hg (reflects right atrial pressure).
PAPPAP: Systolic 15-30mm Hg, Diastolic 6-12mm Hg.
PCWPPCWP: 6 - 12mm Hg. Estimates left atrial heart pressure and left ventricular end diastolic pressure.
COCO: 3.5 - 7.5 L/min
Sv02:Sv02: (70 - 75%). Drawn from the end of the pulmonary artery catheter. Used to calculate how well oxygen is extracted by the tissues.
![Page 39: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/39.jpg)
Page 39
![Page 40: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/40.jpg)
Page 40
the LDP is important with regard to pulmonary artery catheter the LDP is important with regard to pulmonary artery catheter monitoring in three situationsmonitoring in three situations.
The catheter is in the nondependent collapsed lung, the measured cardiac output and mixed venous blood (pvo2) may be decreased.decreased.
When the nondependent lung is ventilated with PEEP and the catheter is in the nondependent lung, Ppaw may not equal , Ppaw may not equal Pla.Pla.
When the catheter is in the dependent lung, Ppaw will be a Ppaw will be a faithful index of Plafaithful index of Pla, even if PEEP is used
![Page 41: Page 2 Introduction Physiological Aspects Monitoring Requirements](https://reader036.vdocument.in/reader036/viewer/2022062308/56649ee45503460f94bf29eb/html5/thumbnails/41.jpg)
Page 41
Monitors are useful adjuncts, But they alone Monitors are useful adjuncts, But they alone cannot replacecannot replace
Careful observation by AnaesthesiologistCareful observation by Anaesthesiologist.