LARGE CAPACITY AIR CONDITIONERSfor offices and sh*pffi
ffiJ**'ffilji|1ft ii !ti,,f , : :t ; t,::;,
Advanced Inverter Technology - Mnre Comfort forEnergy Saving lnverter Large Capacity Air Conditioner for Offices and Shops
SauesThanks to the use of advanced inverter technology and innovative energy-savingtechnology, Panasonic air conditioners lead the industry in energy-savingperformance. Their lower power consumption benefits you two ways, lt saves you
money by reducing your electricity consumption, and it reduces the COz emissions.
Liuing in Harmony with the EnvironmentAt Panasonic, protecting the global environment is a
high priority, Accordingly, we are working to improve
energy efficiency, reduce hazardous substances in
our factories, and cut COz emissions throughout the
production process. These and other efforts are
helping us to minimise impact to the environment.
Energy
ffip;
$ffi
ffiffiili*iiiitil,ffi
--4#:i%*::t'fh"
d'J-Tk%6'-";*'
less Energy
Model Line-Up - TARGE CAPAGITY AIR C0I{DITIOI{ERS -
n0utdoor Unit
(lnuerter|
4#,ffip{{{{ffi€
=Jry-:
CU.YTI gKBH52
ffi+-it{iFffifi=-ffi-
=ffi-rsffi
ff:l't:Tnu"'*''"n' *"
CU.YT24KBH52
@{{-ffi.-..=-...ffi
*=ff"*ffi{ffiffi;
,
CU.YT43KBH52
3
DC Inverter can attain comfortable an
6H
Energy-$?vingoperntionAll the models of Panasonic FS lnverter Series are equipped
with DC inverters for the higher EER operation.
The new design attains the quiet and high-efficient operation
and reduces the running cost.
The Panasonic group's experiences and actual results in thedevelopment of inverters are released in the control. This controlof the inverter demonstrates the optimum compressor torque.The FS series quickly cools the room up to the set temperatureand maintains a comfortable condition, whilst ensuring energyefficiency and savings.
The current waveform deviates fromthe motor voltage waveform, so poweris wasted.
The current waveform closely matchesthe motor voltage waveform, so powerconsumption is reduced.
Power is wasted when the car swingsoff course.
When the car stays right on course,there's no power loss.
Using of a powerful neodymium(rare-metal) magnet for a motor allowedus to make the motor more compact.The winding rotor motor of less magneticfield distortion attains higher efliciency.
*Tlffltr. J
',":, :l'dl
f*f$*: :-4.
it-*r'l I
tt ..rl$
11;ifbl-;
;,i
x i .{iai fl$
'"e{ I
u*jriE* u;;"-* I i
,".." l f,i* tA'. i.
i:' :l?* $1
, utt.i. . !.*.
:i."y.,. ,i
; i: ;J?
l+l:]r",i" .
,F iir,
i*"ja
Hyper Wave lnverterDC lnverter CompressorNew Large Diagonal Air Flow Fan
,il energy-saving operation.
Newly Designed TUrbo Fan$ fn" newly developed three-dimensional blade
shape stabilizes the air flow.The cassette indoor unit is
equipped with a newly-developedturbo fan; the new design releasedlow operation noise and high airflow. ln addition, the DC fan motoris able to give complete control, thisis almost twice as efficient as aconventional motor and enablescomfortable and energy savingoperation.
{}$ Optimizing layout of the indoor heat exchanger,** and the fan enables the increase in the fan diameter.
$lace-savlng designffipwww*€swwEwxffi qse#es€R€str wffi i€Newly designed outdoor unit's fan design has made it possible to reduce the size of the outdoor unit withoutcompromising on quiet and energy efficient operation. Reduction in outdoor unit size enables ease of installation in
smaller spaces. Flexibility in piping gives more freedom in installation leading to reduction in installation cost.
*for 4HP model
These three improvements tominimise the air resistance.
New Large DiagonalAir Flow Fan
The newly designed fan blades reducethe frontal discharge distance.
$--ffi lmproved front grille openingshape
ffi lmproved front grille grid shapeYT34
(lnverter) (795mm
nverter)
tnnuor*c I
I
I
I
I
I
trl.4 ll"#l
, ,f.+l
D34Conventional/Non-i
1,170mm
Both air inlet and outlet are improved.
Top view
Only 30 cm needed
Pursuing the Perfect Design - In Air 0
Panasonic FS Series includes the knowledge for
carefully designing for comfort. Careful
consideration has been given to both air flow
and air quality. A Wired remote controller is also
available, which is equipped with a
high-performance timer to program the operation
mode to meet the requirements of each user.fr's
*#**LJR WASHtrtrK
illffiS#.#' j 'W $HL OdOUf WaSh
Odour Wash reduces any unpleasant odoursproduced from the air conditioner's heat exchanger.
Odour ReinovingONE PUSH
When the air from the outlet smells musty, Moisturein the heat exchanger washes away odours.
Can be operaieci with the wireless remote control.
ffiEconomy Mode
An approximate 2Oo/o* energy-saving operationis attained. The air conditioner judges the stablecondition and moderately shifts the settemperature in O,S-degree steps to control theenergy-saving operation. (Max. 2 degrees)
. During operating in the cooling mode at the remote control set temperatureof 25 under the cooling standard temperature conditions.
Can be operated with the wireless remote control.
6
uality, Airflow, and Convenience
ffiW
Weekly TimerWeekly timer setting (each day of a week) is available to control the air conditioner.Max. 6 settings/day and 42 settings/week can be executed.The setting temperature can be also programmed for optimal comfort.
Set like this for these uses
Closed Saturday afternoon
and all day Sunday.
Mon-Fri 0n 9:00, Off 18:00
Sat 0n 9:00, Off 12:00
Sun Not set
r,r,ririii;r Thg timgr can have
different settings forevery day of the week.
How to set
Select theday.
Example:
Set a lower temperature at
lunch time when a lot ofpersons may visit.
Everyday
0n 12:00 23'C
0n 14:00 28'G
r::,,1:ur lh this CaSe,
the temperature can be
set at the same time.
Example:
To prevent forgetting to
switch OFF weekdays
Mon-Fri
Ofl 20:00
iiiiiiiiiii The timer can be setfor simple shut-off
,
r,f ,l.q&'{.i>i"na]!'.|++{**i*.!*trn
operation. f
{I
,."'*."".,'.""t
Enter thetime.:
NTITEN iMoNTUEwrolDn-snrsq
ON
nffiffim
JT*
)ry].
(digital connection)
,,,,,,,,,,,,,,ii
ffi1gp:::. ftits-- ;l -''-
:l;i *
,,,. i,:;.;.,-i!!:,-,.
noNIt^-/1 \\)t_J
Ventilators are not included in the product line.Optional printed circuit board (lnterface Adapter for ExternalSignals: CZ-TA3OP.) is needed.
*Simple Timer ModeUsing the 24-hour On/Off timer, the operation of On/Off can be set at a same time everyday.
*Printed Gircuit Boardcz-TA3oP.By connecting to the indoor unit, a
separately sold ventilator can be controlled.
oRemote operation control of the indoor unit
is enabled (ON/OFF control).
.The condition of the indoor unit
(malfunctions, operating status) can be
externally output.
.Control in linkage with a total heat
exchanger and the like is possible.
-ii.,4I#zu i:rTilST fttjfqt ru1Tffiffi ffiffiSffiT
.""oo**u,,{,ulr***q-.d{*,e?irt{r,i
-$ifi $lfl,ffi
LJvf; {Tl lVentilation
When the external device such as a ventilator is connected to the indoor unit,switch ON/OFF of the ventilator can be controlled by the wired remote control,Either link-ventilation or independent-ventilation is selectable.
a*#ffiffi
f\d&ruIJAt
nl-f .l:lrl,Jt-l.Lf Lf
Option
SUPER alleru'buster filterSUPER alleru-buster filter uses three types offunctional materials that make it possible toinactivate various harmful airborne elementsincluding allergens, viruses, and bacteria,This filter is available as an option.
<lnactivati ng targets>ts\\$$H$iffiiiffi$Ni"li S i :; ;rt ir' it r ] r';; t i I * I i,.: i i :l ffiS$ffiSffil
ffiAnti-Virus.ww
@Virus
Anti-Bacteria Anti-Mould
wBacteria
*'. .. *?idffMould
CZ-SA11P (For cassette type)CZ-SA12P (For ceiling type)
n
Fast, Flexible lnstallation.750 mm Drain-Up Mechanism
Drain hose can be elevated 750 mm from thebase of the unit simply by connecting anelbow. This adds to ease of drain piping work,and flexibility in locating the indoor unit.
Easy Maintenance andCleaning. Anti-Mould Long-Life Air Filter
SelectableRemote Controller* Customer needs
to choose eitherwired or wireless.
Wired RemoteController
PffiqE
WirelessRemoteController
(Wired Remote Gontroller only)
o24-Hour On/Off Real SettingTimer
. Odour Washo Economy Modeo Auto Restart Functiono Auto Fan Mode. Dry Mode Functiono Self-Diag nostic Function. Optional: SUPER alleru-buster
f ilter (cz-sA11 P)
* The Sound Pressure Level of the outdoor unit shows the value measureci of aposition 1 meter in front of the main body and 1.5 meters from the grcJnd.** When installing the outdoor unit at a higher position than the indocr rnit.
## Add 70mm for oio 'o cori.
ffiwisalap) i\
I
I
I
I
"i
.950 mm
liT[",ffii,,,]1ilffi! 'I,-
.Weekly Timer
Three Airflow Patterns. Multi-Comfort Air Control
* For optimum comfort, werecommend cleaning the air filterevery 1.5 months.
for Extta Gomfort
-7 AUTO 170' 20" - To"
AUTO 2 AUTO 3
Specifications
754mm
+
Room Suspended ceiling
Items
lndoorPanel0utdoor
Cooling
Capacity
Power
Sou rceCurrent
Power
lnput
EER
oT6- cpan ,A(,a- i-=' CJ)
EP.' ='=(o
Air
Volume
Noise Level.
Dimensions NetWeightPiping
ConnectionPipe Length
O
CD
A)
-.-OO=
O- OJo=6ra-CD
Sound
L
,TESSUTC
vel
Sound Power
Level
lndoor(Hi/Lo)
lutdoor(Hi)
I ndoor
(Hi/Lo)0utdoor
(Hi)
=O
-uA)=CD
Oca_Oc)
=o-OO
-!O)=CD
Oca-OO
Gas
Side
Liqu id
Side
Min -Max.
Length
Elevation
Difference(CU up)..CU down
Max
Charge-
less
Length
^oo)
-.cno
=A)
l(W
Btu/h
Phase
Hz
A
(220-230-240)l(W WW m3/min dB(A) dB(A) dB dB
t'1, )\D/
rHr
(s l
('i, l\D/kg kg kg
0.D.
mm( i nch)
0D.mm
(i nch)m m m g/m
cs-T19K84H52cz-BT03PGU.YT1gKBH52
5.60(2 00-6 30)
19,100(6,820-21,500)
tg
220-230-240 t 7 .5-7 .3-7 .1
fnJUi
t.55(0 55-2.20) 3.61 1B 36132 49 51147 67
246840
840
950
95045
795
875+70#t
32026 4.5 65
15.88(5/B)
9.52(3/B) 7.5-30
(25)
2030 1 6-43
GS.T24KB4H52cz-BT03PCU.YT24KBH52
710(2.10-7.70)
24,200(7,160-26,300)
1s
220-230-240
50
'10.1-9 B-9 5
2.14(0 65-2 60) 3.32 20 38i33 50
', 24653/48r 68 I e+o
I 840
95095045
795
875+70##
320
26 4.5 6515.88(5/B)
9.52(3/B) 7,5-30
(25)
2030 1 6-43
GS.T34KB4H52cz-BT03PCU.YT34KBH52
10.00(3.80-11.00)
34,100(13,000-37,500)
1s
220-230-240
5U
6.0-15 3-14.63.45
(1 25-3 e5) 2.90 27 42t37 53
r 2BB
s7l;2 71 840
840
95095045
795
900320
29 4.5 6615 BB
(5/B)9.52(3iB) 7.5-50
(30)
20I30 I SO 16-43 i
l
rlcs-T43K84H52cz-BT03PCU-YT43KBH52
12.50(3.80-1 3 00)
42,600(13,000-44,300)
1s
220-230-240
50
9 7-19.0-18.44,15
(1 25-4 45) 3.01 31 46141 542BB 9s0
840 950
840 45
61/56 72
1 ,170900320
29 4.5 9415 BB
(5/B)9.52(3/B) 7.5-50
(30)
2030 I 50 16-43
Rating Conditions
Easier Maintenance and. Anti-Mould Long Life Air Filter
Antl-Mogld , r :
Long Life,Air Filter
Gleaning. 3-Direction Pipe Lead-OutThe refrigerant piping can be lead out in one ofthree directions (right, rear-right and top-right),and the drain pipe direction can be selectedfrom four directions.
Rear-right
-
SelectableRemote Controller* Customer needs
to choose eitherwired or wireless.
Pslmh
WirelessRemoteController
Wwwmm&#ffiw ffiresem&ffiwmm
o Auto Restart Functiono Auto Fan Mode.Weekly Timer
(Wired Remote Controller only)
o24-Hour On/Off Real SettingTimer
. Odour Wash
. Economy Modeo Dry Mode Function. Self-Diagnostic Functiono Optional: SUPER alleru-busterfilter (cz-sAl2P)
Wired RemoteController
+* For optimum comfort, werecommend cleaning the airfilter every 1.5 months.
Wide Air Discharge, Gomfortable Gontrol. Wide-Angle Airflow
- 100 DegreesHorizontal
Wdl-to-WallComfort Even in
Large Rooms
"ft
sideView r-,-=70' ,/
V Swinging louver (automatic)
Specifications
. Auto Swing Louver
Items
lndoor0utdoor
Cooling
Capacity
Power
SourceCurrent
Power
lnput
EER
oT6- CD
UQ='(J)=<o'='=(o
Air
Volume
NoiseLevel.
Dimensions Net WeightPiping
ConnectionPipe Length
O-ct(Dq)
=.^oO=
O- AJO=C) (O
-CD
SoundPressure
Level
SoundPower
Level
lndoor
(Hi/Lo)0utdoor
(Hi)
lndoor
(HiiLo)
0utdoor
(Hi)
5aOo
Oco-OO
=o-oO
OCO-oo
Gas
Side
Liquid
Side
Min -Max.
Length
Elevation
Difference
(CU up)..CU down
Max.
Charge-
less
Length
o-^o_a) :=ut c)
A)
l(W
Btu/h
Phase
V
Hz
A
(220-230-240) KW WVV m3/min dB(A) dB(A) dB dB (fr),lf,(l,l
kg kg
0,D
mm
(i nch)
ODmm
(i nch)
m m m g/m.C
CS.TIgKTH52CU-YTl9KBH52
560(2.00-6.30)
19,100(6,820-21,500)
1s220-230-240
50B B-8.6-8,4
1.86(0 60-2.35)
301 17 43/39 49 60/56 67
2t01,245
700
795
875+70##
32033 65
15.88(5/B)
952(3/B) i 5-30
(25)
2030 1 6-43
cs-T24KTH52CU.YT24KBH52
7.10(2 00-7.50)
24,200(6,820-25,600)
1fr220-230-240
50
11.7-11.4-11.1 2.53(0.70-2.70\ 2.81 18 45141 50 62158 6B
2101,245700
795875+70**
32033 65
15 88(5/B)
952(3/B) 7.5-30
(25)
2030 1 6-43
cs-T34KTH52CU.YT34KBH52
9.30(3,80-10,50)
31,700(1 3,000-35,800)
1s
220-230-24050
16 4-15 6-i4 B3.50
(1.30-4.10) 266 29 47 t43 53 64/60 71
250
1,600700
795900320
43 6615 BB
(5/8)9.52(3/B) 7.5-50
(30)
2030 50 1 6-43
cs-T43KTH52CU-YT43KBH52
12.50(3.80-13.00)
42,600(13,000-44,300)
1s
220-230-24050
21 0-20.3-19 8 4.45(1.30-4.70) 2.81 31 49145 54 66162 72
2501,600700
1 ,170900320
47 g4 15.88(5/B)
9.52(3/B) 7.5-50
(30)
2030 50 1 6-43
Rating Conditions
Cooling
lnside air temperature 27"C DB|19'C WB
Outside air temperature 35"C DB/24'C WB
* The Sound Pressure Level of the outdoor unit shows the value measured of aposition 1 meter in front of the main body and 1.5 meters from the ground,** When installing the outdoor unit at a higher position than the indoor unit.
## Add 70mm for piping port.
I
n
Thin (Only 29 cm*I,Lightweight DesignThe unit has a height of only 29 cm, so itallows installation in limited ceiling spaces,The lightweight, attractive design simplifiesinstallation, and matches virtually all room
Flexible lnstallationThe powerful airflow enables a longer duct tobe used, Since the air outlet can be installedaway from the main unit, a variety of airconditioner layouts become possible.
Easy MaintenanceMaintenance works can be done from theunderside of the indoor unit.
Remote Controller* A remote controller is inthe same package with theindoor unit.
Wired RemoteController
ffi ,r# ** *;1F ggl t; :il :$,r,lt
o Auto Fan Mode. Auto Restart Functiono Dry Mode Function.Weekly Timero24-Hour On/Off Real SettingTimer
. Odour Washr Economy Mode. Self-Diag nostic Function
* The Sound Pressure Level of the outdoor unit shows the value measured of aposition 1 meter in front of the main body and 1.5 meters from the ground.** When installing the outdoor unit at a higher position than the indoor unit.
## Add TOmm for piping port.
interiors.. 2.5 HP / 3.0 HP models.
Specifications
lndoor0utdoor
Cooling
Capacity
Power
SourceCurrent
Power
lnput
EER
^ t-T1(J=
!2.<
=<.'-'f(o
Air
Volume
External
Static
Pressure
Noise Level.
Dimensions NetWeightPiping
ConnectionPipe Length
O-o(D
=.-OUJ
O- A)o=oq
SoundPressure
Level
SoundPowerLevel
lndoor
(Hi/Lo)0utdoor
(Hi)
lndoor
(Hiilo)0utdoor
(Hi)
=o_OO
OCo-OO
=o-Oo
O
o-OO
Gas
Side
Liquid
Side
Min -Max.
Length
Elevation
Difference
(CU up)..CU down
Max.
Charge-
less
Length
O-^og /
-.a)=U)O
=q)
l(W
Btu/h
Phase
V
Hz
A
(220-230-240)krnl *^ u3/oin',*lXo, dB(A) dB(A) dB dB
rHr(l'l ('X,
)\D/kg kg
OD
mm
O,D
mmm m m g/m
.C
cs-T19KD2H5CU-YT19KBH52
5.60(2 00-6 30)
19,100(6,820-2r 500)
1s
220-230-24050
B B-8 5-8 31.86
(0 60-2 35)3.01
A0 l22 in "45t4149 62158 67
2901 ,000+100
500
70(
875+70**320
35 6515.88(5/B)
952(3/B)
7.5-30(25)
2030 1 6-43
cs-T24KD2H5CU.YT24KBH52
7.10(2 00-7 50)
24,200(6,820-25,600)
1s
220-230-24050
12.0-11.6-11.22.53
(0.70-2 70)2.81 22 I |,l 4st4i 50 62lsB 6B
290
1 ,000+100500
795
875+70##
32035 65
15.88(5/B)
9.52(3/B)
7.5-30(25)
2030 1 6-43
cs-T34KD2H5CU.YT34KBH52
10.00(3 80-10.50)
34,100(13,000-35,800)
1s
220-230-240 1 7.3-1 6.7-1 6,1
50
3.65(1 .30-4 1 0)
2.74 350a
tiof 4st45 s3 64160 71
3601 ,000+100
650
795
900320
48 6615.88(5/B)
9.52(3/B)
7.5-50(30)
2030 50 1 6-43
cs-T43KD2H5CU.YT43KBH52
12 50(3 80-1 3 00)
42,600(1 3 000-44,300)
1s
220-230-24050
20.9-20 3-l9.6 442(1 30-4 70)
283 35t?fif '4et45 54 64/60 72
3601,000+100
650
1,170900320
48 9415 BB
(5iB)952(3/B)
7.5-50(30)
2030 50 1 6-43
Rating Gonditions
Cooling
lnside air temperature 27'C DBl19'C WB
Outside air temperature 35"C DB/24"C WB
10
ronwor*ciffiJii?'*
FbHfifo
V,fUe*mn!l*FaE{e,
2.5 HP - 3.0 HP 4.0 HP
Flexible lnstallation in Smaller SpacesA variety of improvements has reduced installation time and space.
. Space-Saving Outdoor UnitBy improving the fan, we were able to make the outdoor unitsmall enough to fit in spaces too tight for conventional units.
5.0 HP
. Centralized Drain MethodThe drain outlets can be gathered into a single drain pipe evenwhen multiple outdoor units are installed to a wall.
.50m Long PipingPiping can be extended up to30 meters without additionalgas charging, and up to 50meters with additional gascharging.By giving you more flexibilityin positioning the outdoor unit,this gives you a wider rangeof installation options.
. Side-by-Side Gontinuous lnstallationEven outdoor units with different capacities can be installed sideby side in an efficient, orderly layout. To make this possible, wehave positioned the service port in the front and given all modelsthe same depth..Except 2.5 - 3HP
Quiet, Efficient Design FanA host of silencing technologies achieves super-quiet operation.We've also improved operating efficiency and reduced energyconsumption.
. Flexible 4-Way PipingPiping can be routed in anyof four directions.
*For 4.0HP, S OHP
#Gas is pre-charged lor 30m. (Additional gas is required when pipe length is extended.).1
When installing the outdoor unit at a higher position than the indoor unit..2
When installing the outdoor unit at a lower position than the indoor unit.
Noise-SuppressingWinglet Fan
,t
Mo,re than'50cm needed :
.rr--rra
Max.50m #
Pipelength
Max.30m *
Heightdifference
2,5-3.0 HP 4.tlHP 5.0 HP
Max. Length * 30m 50m 50m
Max. Ghargeless Length 30m 30m 30m
Max. Height Diflerence # 25 m*l20 m*2
30. m*1
20 m*2
30 m*l20 m*2
11
c s -T1 9 KB4 H 52lC S -T 24K84H52 GS-T34K84H52/CS-T43 KB4H52
(unit: mm)
Required space for installation
9-(o o'l'l.r)ElN-1.
o-,1-
When raising the drain headabove the unit
Wireless remote controllerPhoto receiver unit position
pipe(liquid side)
-
LJ
l-
(unit: mm)
fresh air inlet position
%
Required space for installation
c).-@otorclc\t -.1.
o*,f-
oa(D
o+OtolLcf)
Beam
When raising the drain headabove the unit
drain port
Wireless remote controllerPhoto receiver unit position
pipe(liquid side)
:t-I- 1\
(unit: mm)
Wireless remote controllerreceptor unit position
Required space for installation
orN
111
1
N.Ir-'^
\:r\nryr
.]IUN
5oO or more .l_il
I cs-t1 9KTHoz/GS -Tz4KTHb2 I cs-Ta4KTHbz/cs-T4g KTHsz
OroN
14701 600
m)
Wireless remote controllerreceptor unit position
Required space for installation
S'.ll@tJlULSOO or rot" l+'TTF
500or more
IItI
i
te
I cs-tl oKD2Hb/cs -Tz4KD2Hb
(unit: mm)
Required spa
Top view
ce for installation
lnspection780(P65 x 12)
840
1 000
I c s -t g4KDzH b/G s -T43 KDz H s
(unit: mm)
Required space
Top view I
for installation
nspection
7--T-7-T-7--T-77'7'7-T-T-7-7'7
13
* cu-YTl gKBHbz
CU.YTzfiKBH52
Space for.prprng, wilngand maintenance
-{OIcp
'I
'131) 613 -_'131
Front piping hole(Knock out hole)
Right piping hole(Knock out hole)
Air outlet sidem900
E
-il
illur
/:lic(lll ,Y Right piping hole
(Knock out hole)
14
fwired Remote Controllercz-RDsl3C(For Cassette Type and Ceiling Type)
* A wired remote controller isincluded with hide-away types.
lwireless Remote ControllerCZ-RLOI38 (For Cassette Type)
CZ-RLO13T (For Ceiling Type)
WirelessControllerReceiver(For CassetteTvpe)
w f:-'E Wireless ControllerReceiver(For Ceiling Type)
. Group Control by a SingleRemote Controller
. Separate Control byTwin Remote Gontrollers
Remote-side Local-sideremote controller remote controller
(either wired or wireless)
o Each indoor unit can be operated by either of the tworemote controllers,
o Apart from the timer setting time, the displays for the tworemote controllers are identical.
o The last button pressed has priority (The main or slaveattribute is set with the remote controller).
o Common Control by Both Wiredand Wireless Remote Controllers
Receptor unit
Wirgdremote I Ivvrr\=rttrr
controller t-i controller
eThe last button pressed has priority(using either wired or wireless remote controllers).
Wireless remotecontroller
lndoor unitsRemote-sideremote controller
oAll indoor units operate in the same mode.
15
Environmental Management Systems Gertificate
Gertified to ISO 14001:2004Panasonic HA Air-Conditioning (M) Sdn.Bhd.
Cert. No.: MY-ER 0112
MI UKAS IIrruvrrowrNnl I
I MANAGEMENT I
,/\/eruvrnoruuerutlt\\ svsreu )v
System Certificate
#wGertified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M) Sdn.Bhd.Cert. No.: MY-AR'1010
Quality Management
. Specifications and designs are subject to change without notice.SG-YI-10
Panasonid