PG738EX-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect a jumper between "reset jumper" pins. (3) Connect AC then the battery. (4) Wait 10 seconds. (5) Remove jumper. Factory default installer and master codes will be reinstated. Values entered at addresses 008-043, 062-126 and 300-527 as well as all user codes, will be erased ([2ND] [2ND]). Programmed values of all other addresses do not change. HEXA PROGRAMMING: All digits from 0 to F are valid. Values are programmed into memory locations from address 000 to 043 and from address 300 to 527. 1) Press [ENTER] + installer code. 2) [ENTER] will flash (programming mode). 3) Enter 3 digit memory address. 4) Current value will be displayed on keypad. 5) Enter 2 digit data. 6) Go to step 3 for next address. To exit programming mode, press [CLEAR]. STREAMLINED SECTION PROGRAMMING Can be used to program sections 00 to 67. (addresses 000 to 043 and 300 to 527) Press [ENTER], installer code, and [7]. ([2ND] and [ENTER] keys alternately flash.) Enter a 2-digit section number, followed by 8 digits to program that section (confirmation beep). Data will be saved automatically and the software advances to the next programming section. To exit programming mode press [CLEAR]. INSTALLER CODE: (reset code 737373) (addresses 000, 001, 002) SECTION 00 Full access to programming, except access codes. (addresses 127-299) No access to arming/disarming. Can be used to modify installer code. Use only numeric keys from [1] to [10]. (key [10] = 0) PANEL ANSWER OPTIONS: (address 003) SECTION 00 First digit disables “Answering Machine Override” (key [2ND] or key [1]), or determines period of time between first and second call (see table below). Second digit determines number of rings required before panel will answer. If [2ND][2ND] is entered, panel will not answer. (Default value is [2ND] [8].) - 1 - Value of 2 ND digit = 10 ( 8 + 2 = 10) Value of 1 ST digit = 3 ( 2 + 1 = 3) VALUE = "3A" HEXA DISPLAY No display = SKIP (empty) No light = 0 10 = [0] = [A] If key is lit = 8 = 4 = 2 = 1 If key is lit = 8 = 4 = 2 = 1

Upload: dan-raducanu

Post on 28-Oct-2015

618 views

Category:

Documents


4 download

DESCRIPTION

engleza / englishV3.1

TRANSCRIPT

PG738EX-961212-0004

SOFTWARE VERSION 3.10CONTROL PANEL RESET:Installer lock must be unlocked. (Address 058: enter any value other than 147)

Power down reset(1) Remove battery and AC to power down the unit.(2) Connect a jumper between "reset jumper" pins.(3) Connect AC then the battery.(4) Wait 10 seconds.(5) Remove jumper.

Factory default installer and master codes will be reinstated. Values entered at addresses 008-043, 062-126 and 300-527as well as all user codes, will be erased ([2ND] [2ND]). Programmed values of all other addresses do not change.

HEXA PROGRAMMING:All digits from 0 to F are valid. Values are programmed intomemory locations from address 000 to 043 and from address300 to 527.

1) Press [ENTER] + installer code.2) [ENTER] will flash (programming mode).3) Enter 3 digit memory address.4) Current value will be displayed on keypad.5) Enter 2 digit data.6) Go to step 3 for next address.To exit programming mode, press [CLEAR].

STREAMLINED SECTION PROGRAMMINGCan be used to program sections 00 to 67. (addresses 000 to 043 and 300 to 527)Press [ENTER], installer code, and [7] . ([2ND] and [ENTER] keys alternately flash.)Enter a 2-digit section number, followed by 8 digits to program that section (confirmation beep). Data will be savedautomatically and the software advances to the next programming section. To exit programming mode press [CLEAR].

INSTALLER CODE: (reset code 737373) (addresses 000, 001, 002) SECTION 00Full access to programming, except access codes. (addresses 127-299) No access to arming/disarming. Can be used tomodify installer code. Use only numeric keys from [1] to [10] . (key [10] = 0)

PANEL ANSWER OPTIONS: (address 003) SECTION 00First digit disables “Answering Machine Override” (key [2ND] or key [1] ), or determines period of time between first andsecond call (see table below). Second digit determines number of rings required before panel will answer. If [2ND][2ND]is entered, panel will not answer. (Default value is [2ND] [8] .)

- 1 -

Value of2ND digit = 10( 8 + 2 = 10)

Value of 1ST digit = 3( 2 + 1 = 3)VALUE = "3A"

HEXA DISPLAY

No display = SKIP (empty) No light = 0

10 = [0] = [A]

If key is lit = 8 = 4 = 2 = 1

If key is lit = 8 = 4 = 2 = 1

TELEPHONE AND ACCOUNT NUMBERS: (reset empty )If only one central station phone number is used, program the same number for telephone number 1 and 2.

[10] = the number "0" [BYP] = switch from pulse to tone while dialing[11] = * [MEM] = pause 4 seconds[12] = # [TRBL] = end of number

COMPUTER TELEPHONE NUMBER: (View at addresses 008 to 015.)

02 __ / __ / __ / __ / __ / __ / __ / __ 03 __ / __ / __ / __ / __ / __ / __ / __1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

CENTRAL STATION TELEPHONE NUMBER 1: (View at addresses 016 to 023.)

04 __ / __ / __ / __ / __ / __ / __ / __ 05 __ / __ / __ / __ / __ / __ / __ / __1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

CENTRAL STATION TELEPHONE NUMBER 2: (View at addresses 024 to 031.)

06 __ / __ / __ / __ / __ / __ / __ / __ 07 __ / __ / __ / __ / __ / __ / __ / __1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ACCOUNT "A" AND "B": (View at addresses 032 to 035.)

08 ___ / ___ / ___ / ___ ___ / ___ / ___ / ___1 2 3 4 5 6 7 8

A B

If only one account number is required, the same number must be entered for both account "A" and "B".

- 2 -

PG738EX

Press [ TRBL] to endphone number if lessthan 16 dig its areprogrammed.

Press [ TRBL] to endphone number if lessthan 16 dig its areprogrammed.

For 3 digit accountnumbers, enter "skip"([2ND]) as first digit.

Press [ TRBL] to endphone number if lessthan 16 dig its areprogrammed.

Streamlinesection

Streamlinesection

Streamlinesection

Streamlinesection

Streamlinesection

Streamlinesection

Streamlinesection

[2 ]ND

[2 ]ND [2 ]ND

Streamlinesection

Data Description Address

___/______/___

/

___/___

___ ___

Future use1st digit: value must be entered i.e.2nd digit: time correction (See table)1st digit: telephone 1 format2nd digit: telephone 2 format1st digit: PGM 1 type2nd digit: PGM 2 type

[2 ]ND

036037

038

039

09

PGM 1PGM 2PGM mask 1PGM mask 2

040041042043

___/______/___

/___/______ ___10

TIME CORRECTION:(address second digit)037

[2 ][1][2][3][4][5][6][7]

ND - No adjustment- Plus 4 sec.- Plus 8 sec.- Plus 12 sec.- Plus 16 sec.- Plus 20 sec.- Plus 24 sec.- Plus 28 sec.

[8][9][10][11][12][ ][ ][ ]

- Minus 4 sec.- Minus 8 sec.- Minus 12 sec.- Minus 16 sec.- Minus 20 sec.- Minus 24 sec.- Minus 28 sec.- Minus 32 sec.

BYP

MEM

TRBL

COMMUNICATOR FORMATSKey

[2 ][1][2][3][4][5]

ND [6][7][8][9]

[10][ ]TRBL

= slow (1400Hz, 1900Hz, 10bps)= (1400Hz, 1800Hz, 10bps)= fast (1400Hz, 1900Hz, 20bps)= (2300Hz, 1800Hz, 20bps)= (40bps with 1400Hz handshake)= (40bps with 2300Hz handshake)

ADEMCO

SILENT KNIGHTSESCOARADIONICSRADIONICS

= with PARITY (1400Hz, 40bps)= with PARITY (2300Hz, 40bps)= express= contact ID (programmable codes)= contact ID (all codes)= - no handshake (personal dialing)

RADIONICSRADIONICSADEMCOADEMCOADEMCODTMF

- 3 -

PG738EX

For addresses to , see pages 7 to 10.044 126

CID100:110:111:112:113114:115:116:117:118:120:121:122:123:130:131:132:133:136:137:138:140:150:151:152:153:154:155:156:157:158:159:161:

CID300:301:302305:306:309:320:321:323:350:351:354:370:371:372:373:382:383:400:401:402:403:404:407:410:441:570:572:573:574:601:602:625:

PROG. VALUE[2 ] / [1][2 ] / [2][2 ] / [3][2 ] / [4][2 ] / [5][2 ] / [6][2 ] / [7][2 ] / [8][2 ] / [9][2 ] / [10][2 ] / [11][2 ] / [12][2 ] / [ ][2 ] / [ ][2 ] / [ ][1] / [2 ][1] / [1][1] / [2][1] / [3][1] / [4][1] / [5][1] / [6][1] / [7][1] / [8][1] / [9][1] / [10][1] / [11][1] / [12][1] / [ ][1] / [ ][1] / [ ][2] / [2 ][2] / [1]

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND BYP

ND MEM

ND TRBL

ND

BYP

MEM

TRBL

ND

PROG. VALUE[2] / [2][2] / [3][2] / [4][2] / [5][2] / [6][2] / [7][2] / [8][2] / [9][2] / [10][2] / [11][2] / [12][2] [ ][2] [ ][2] [ ][3] / [2 ][3] / [1][3] / [2][3] / [3][3] / [4][3] / [5][3] / [6][3] / [7][3] / [8][3] / [9][3] / [10][3] / [11][3] / [12][3] [ ][3] [ ][3] [ ][4] / [2 ][4] / [1][4] / [2]

///

///

BYP

MEM

TRBL

ND

BYP

MEM

TRBL

ND

REPORTING CODEAUXILIARY ALARMFIRE ALARMFIRE SMOKECOMBUSTIONWATER FLOWHEATPULLSTATIONDUCTFLAMENEAR ALARMPANIC ALARMDURESSSILENT PANICAUDIBLE PANICBURGLARYPERIMETER BURG.INTERIOR BURG.24HR BURGLARYBURGLARY OUTDOORBURGLARY TAMPERBURGLARY NEAR ALARMGENERAL ALARM24 HOUR AUXGAS DETECTEDREFRIGERATIONLOSS OF HEATWATER LEAKAGEFOIL BREAK ALARMDAY TROUBLE ALARMLOW GAS LEVELHIGH TEMPERATURELOW TEMPERATURELOSS AIR FLOW

REPORTING CODESYSTEM TROUBLEAC LOSSLOW SYSTEM BATTERYSYSTEM RESETPROGRAM CHANGEDBATTERY TEST FAILSOUNDER/RELAY TROUBLEBELL 1 TROUBLEALARM RELAY TROUBLECOMMUNICATION TROUBLETELCO 1 FAULTFAIL TO COMMUNICATEPROTECTION LOOP TROUBLEPROTECTION LOOP OPENPROTECTION LOOP SHORTFIRE LOOP TROUBLESENSOR TROUBLESENSOR TAMPEROPEN/CLOSEOPEN/CLOSE BY USER #GROUP OPEN/CLOSEAUTOMATIC OPENING/CLOSINGLATE TO OPEN/CLOSEREMOTE ARM DOWNLOADREMOTE ACCESSOPEN/CLOSE - STAY MODEBYPASS24 HOUR ZONE BYPASSBURGLARY BYPASS #GROUP BYPASSMANUAL TESTPERIODIC TESTTIME/DATE RESET

PROGRAMMABLE CONTACT ID EVENT CODESAll addresses from to (sections to ) programmed with values other than will report the contactID codes corresponding to the values programmed. Values to be programmed should be selected from this table.

300 527 11 67 [2 ] [2 ]ND ND

- 4 -

REPORTING CODES: (reset code = “empty" )All digits from to are valid. Enter (skip) = digit will not be reported except for contact I.D. programmable codes.For single digit reporting enter "skip" ( ) as first digit.

(Select Contact I.D (all codes) - key for both central station numbers at section - address .)

[2 ] [2 ][1] [F] [2 ]

[2 ]

[10] 09 038

ND ND

NDND

If CONTACT I.D. format (all codes) is selected, addresses 300 to 527 (sections 11 to 67) do not have to be programmed.

PG738EX

___/______/___

/___/______ ___

Auto / EsploadMasterUser code 1User code 2

300301302303

Streamlinesection

Streamlinesection

Data DataDescription DescriptionAddress AddressARMING CODES:(closing)

___/______/___

/____/______ __

User code 23User code 24User code 25User code 26

324325326327

17

11

___/______/___

/___/______ ___

User code 3User code 4User code 5User code 6

304305306307

___/______/___

/____/______ __

User code 27User code 28User code 29User code 30

328329330331

12

18

User code 7User code 8User code 9User code 10

User code 15User code 16User code 17User code 18

308309310311

316317318319

User code 31User code 32User code 33User code 34

User code 39User code 40User code 41User code 42

332333334335

340341342343

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/___

/___/______ ___

13

15

19

21User code 11User code 12User code 13User code 14

User code 19User code 20User code 21User code 22

312313314315

320321322323

14

16

User code 35User code 36User code 37User code 38

User code 43User code 44User code 45User code 46

User code 47User code 48 /(Duress)

See next page

336337338339

344345346347

348349

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/___

___/______/___

/____/______ __

___/______/___

/____/______ __

20

22

23

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

___/______/___

/____/______ __

PG738EX

- 5 -

REPORTING CODES: (reset code )"empty"

Streamlinesection

Streamlinesection

Data DataDescription DescriptionAddress AddressDISARMING CODES:(opening)

___/______/___

/____/______ __

User code 21User code 22User code 23User code 24

372373374375

29

___/______/___

/___/______ ___

User code 1User code 2User code 3User code 4

352353354355

___/______/___

/____/______ __

User code 25User code 26User code 27User code 28

376377378379

24

30

User code 5User code 6User code 7User code 8

User code 13User code 14User code 15User code 16

356357358359

364365366367

User code 29User code 30User code 31User code 32

User code 37User code 38User code 39User code 40

380381382383

388389390391

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/___

/___/______ ___

25

27

31

33User code 9User code 10User code 11User code 12

User code 17User code 18User code 19User code 20

360361362363

368369370371

26

28

User code 33User code 34User code 35User code 36

User code 41User code 42User code 43User code 44

User code 45User code 46User code 47User code 48 /(Duress)

384385386387

392393394395

396397398399

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/______/______/___

___/______/___

/____/______ __

___/______/___

/____/______ __

32

34

35

EsploadMaster

See previous page

350351

___/______/___

Streamlinesection

Streamlinesection

Data DataDescription DescriptionAddress AddressALARM CODES ZONE 1 TO 12:

___/______/___

/___/______ ___

Zone 5Zone 6Zone 7Zone 8 Keypad 1

404405406407

N/AN/AN/AN/A

412413414415

37

39

Zone 9N/AN/AN/A

Keypad 2 408409410411

N/AN/AN/AN/A

416417418419

___/______/___

/___/______ ___

___/______/___

/___/______ ___38

40

N/AN/AN/AN/A

420421422423

___/______/___

/___/______ ___41

Zone 1Zone 2Zone 3Zone 4

(fire)

400401402403

(see add. 100)

___/______/______/______/___

36

23

ALARM CODES ZONE 13 TO 24:

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND

[ ]2ND [ ]2ND

PG738EX

- 6 -

REPORTING CODES: (reset code )"empty"

Streamlinesection

Streamlinesection

Streamlinesection

Streamlinesection

Data

Data

Data

Data

Description

Description

Description

Description

Address

Address

Address

Address

ZONE 1 TO 12 RESTORE CODES: ZONE 13 TO 24 RESTORE CODES:

ZONE 1 TO 12 SHUTDOWN CODES: ZONE 13 TO 24 SHUTDOWN CODES:

___/______/___

/___/______ ___

___/______/___

/___/______ ___

Zone 5Zone 6Zone 7Zone 8 Keypad 1

Zone 5Zone 6Zone 7Zone 8 Keypad 1

428429430431

452453454455

___/______/___

/____/______ __

___/______/___

/____/______ __

N/AN/AN/AN/A

N/AN/AN/AN/A

436437438439

460461462463

43

49

45

51

Zone 9N/AN/AN/A

Keypad 2

Zone 9N/AN/AN/A

Keypad 2

432433434435

456457458459

N/AN/AN/AN/A

N/AN/AN/AN/A

440441442443

464465466467

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/___

/___/______ ___

___/______/___

/___/______ ___

44

50

46

52

N/AN/AN/AN/A

N/AN/AN/AN/A

444445446447

468469470471

___/______/___

/___/______ ___

___/______/___

/___/______ ___

47

53

Zone 1Zone 2Zone 3Zone 4

(fire)

Zone 1Zone 2Zone 3Zone 4

424425426427

(see add. 100)

448449450451

___/______/______/______/___

___/______/______/______/___

42

48

Streamlinesection

Streamlinesection

Data DataDescription DescriptionAddress AddressTAMPER 1 TO 12 TROUBLE CODES: TAMPER 13 TO 24 TROUBLE CODES:

___/______/___

/___/______ ___

Tamper 5Tamper 6Tamper 7N/A

476477478479

___/______/___

/____/______ __

N/AN/AN/AN/A

484485486487

55

57

N/AN/AN/AN/A

480481482483

N/AN/AN/AN/A

488489490491

___/______/___

/___/______ ___

___/______/___

/___/______ ___56

58

N/AN/AN/AN/A

492493494495

___/______/___

/___/______ ___59

Tamper 1Tamper 2Tamper 3Tamper 4

472473474475

___/______/______/______/___

54

DECIMAL PROGRAMMING3 Digit Decimal Value ProgrammingUsed to program addresses 044 to 061. Values entered must contain 3 digits between "000" and "255". ([10] = 0)

Decimal value programming:1) Press [ENTER] + installer code. ([ENTER] key will flash.)2) Enter 3 digit address (044 to 061).3) Current value will be displayed on keypad.4) Enter 3 digit DECIMAL value.5) Repeat from step 2 onward for next address. To exit programming mode press [CLEAR].

044: ___/___/___ (hours) Auto arm time (between "000" and "023")

045: ___/___/___ (minutes) Auto arm time (between "000" and "059")

046: ___/___/___ (days) Auto test report every ? days (between "001" and "255") (000 = disabled)

047: ___/___/___ (hours) Auto test report (between "000" and "023")

048: ___/___/___ (minutes) Auto test report (between "000" and "059")

- 7 -

PG738EX

DECIMAL PROGRAMMING049: ___/___/___ (seconds) Exit delay (factory default 60 seconds)

050: ___/___/___ (seconds) Entry delay 1 (factory default 45 seconds)

051: ___/___/___ (seconds) Entry delay 2 (factory default 45 seconds)

052: ___/___/___ (minutes) Bell cut-off time (factory default 5 minutes)

053: ___/___/___ ( x 15 mSec.) Zone speed (factory default 600 mSec.)

054: ___/___/___ (minutes) Power failure report delay (factory default 30 minutes) (000 = disabled)

055: ___/___/___ ( x 15 minutes) "No movement" report time (factory default 8 hours) (000 = disabled)

056: ___/___/___ PGM timer setting (001 to 127 for seconds and 129 to 255 for minutes) (factory default 5 seconds)Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 + 128 = 133)

057: ___/___/___ Intellizone delay (in seconds, minimum = 10 seconds) (factory default 48 seconds)

058: ___/___/___ Installer code lock (147 = locked, 000 = unlocked)

059: ___/___/___ (seconds) Programmable delay before alarm transmission (5 to 63 seconds) (000 = disabled)

060: ___/___/___ (seconds) Recent closing delay (000 = disabled)

061: ___/___/___ Future Use

FEATURE SELECT PROGRAMMINGAddresses 062-126. "ON"/"OFF" status of the key lights determines feature selection. In programming mode, enter 3 digit memory address (062 to 126). To save entries, press [ENTER]. To exit programming mode press [CLEAR]. Reset = “OFF” for addresses 062 to 126.

Addresses 080 to 085 for future use.

- 8 -

PG738EX

[5]

[2]

[4]

[2 ]ND

[1]

[3]

[6]

[11]

[8]

[10]

[7]

[9]

[12]

[ ]BYP

[ ]BYP

[ ]MEM

[ ]MEM

[ ]TRBL

[ ]TRBL

- 9 -

stay arm / System A

enabledenabled

Bell squawk on arm/disarmAuto zone shutdown

See "Reporting" table

(1:1.5) Pulse USA(1:2) Pulse Europe

enabledenabledenabled

Auto arm on timeAuto arm on no movement

[5]

[2]PS1/Keyswitch = regular arm

[4] enabledCall back

[2 ]ND

[1]See "TLM" table

[3] enabledPS1/keyswitch arming

[6]

generates only a reportSilent zone/panic generates a silent alarm

[11]

[8]

[10]

[7]Pulse dialingPartitioning

Tone dialing (DTMF)enabled

[9]

[12]

086:KEY

[ ]BYP

[ ]MEM

[ ]TRBL

OFF / ON

only after alarm

audible

enabled

audibleenabled

fire

on zone closure

4 digit

enabled

enabled

enabled

088: OFF / ON

enabledenabled

KEY

no EOL

Report zone restore on bell cut-off

Panic 2Panic 3

Tamper Recognition

Panic 1Automatic event buffer transmission

Always report disarm

Panic 2 silentPanic 1 silent (PS1)

Panic 3 silent

6 digit access codes

Key regular arm[10]Key stay or system A arm[11]

Beep on exit delay

Zones with EOL (1K )Ω

(keys & , )[1] [3] PS1(keys &[4] [6])

(keys & )[7] [9]

TELEPHONE LINE MONITOR

TLM generates trouble onlyTLM disabled

generates an alarm if armedsilent alarm becomes audible

(address , key has to be )086 [9] OFF

KEY

[2 ]ND [1]

OFF OFFONOFF

ONON

OFFON

Address 086, Key [2 ] [1]ND

OFF OFFONOFF

ON

ON

OFF

ON

REPORTING OPTIONS

Regular reportingReporting disabled

Split reporting: AlarmsSystem report

Double reporting

KEY DIALING SEQUENCE (tel. No.)TYPE[11] [12]

1,2,1,2,1,2,1,2, fail to comm.1,1,1,1,1,1,1,1, fail to comm.2,2,2,2,2,2,2,2, fail to comm.1,1,1,1,1,1,1,1, fail to comm.,2,2,2,2,2,2,2,2, fail to comm.

*

On alarm, all reports are made to Tel. #1 until system is disarmed.(Once disarmed, system reports are made to Tel. #2)

*

Address 086, Key [11] [12]

N/A N/A

090:Exclude power failure from trouble display [2 ]ND

OFF / ON

[3]

[1]

enabled

[2] stay / System AAuto arm = regular arm

KEY

[6] tamper follows zone bypass definitionNo tamper bypass

[5]

[4]

enabled

enabled

enabledenabled

[7]

[8]

[9]

[10]

[11]

[12]

FEATURE SELECT PROGRAMMING (continued)(On/off status of key lights determines which feature is selected.)

Audible trouble warning

Duress

Keypad 1 zone supervision

Keypad 2 zone supervision

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

PS1 software versionKeypad software versions prior to

1.14.0 Keypad supervision must be OFF

PS1 software versions onwardKeypad software versions onward

2.04.0 Keypad supervision must be ON

(See Wiring Diagram)

PG738EX

TAMPER / WIRE FAULT DEFINITIONS

Exception: for 24 hour zones the tamper definition will follow theaudible/silent alarm definition of the 24 hour zone.Silent zones will generate a silent alarm.

Tamper supervisiondisabled

Alarm as per individualzone definitions

No alarm, trouble codereported

Audible alarm. Trouble andalarm codes reported

Silent alarm. Trouble andalarm codes reported

Always generate troubleand alarm, audible orsilent as per individualzone definitions

SYSTEM ARMED

**

**

Address 088, Key [10] [11]

*

SYSTEM DISARMED*KEY

[11][10]

OFF OFF

OFF ON

ON OFF

ON ON

Note: Do not use the Intellizone feature and an entry delay for the same zone, otherwise an alarm may occur as a usertries to disarm the system.

KEY ACCESS PROGRAMMINGPrograms features quickly, without entering addresses or section numbers.To activate “key access programming”, press [ENTER], followed by installer, master or user code 1. (Code required depends on the feature you wish to access - see below.) Press the key corresponding to the desired feature. Press [ENTER] or [CLEAR] to exit.

key

[8] Installer test mode (installer code only)In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long) indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones.

[9] "Auto arming" time program (all 3 codes)Key [9] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes.

[MEM] "Panel time" and clear "trouble 8" (all 3 codes)Key [MEM] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes.

[BYP] Test report (all 3 codes)Reporting is enabled at address 086, keys [11] , [12] . A value must be entered at address 512, and both telephone and account numbers must be programmed.

[TRBL] Call Espload via telephone (all 3 codes)Panel identifier and PC password (addresses 004-007) and computer telephone number (addresses 008-015) must be programmed.

[AWAY] Answer Espload (all 3 codes)This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in "modem setup" section, and panel phone number programmed (works also without ADP-1).

[STAY] Cancel communication attempts (master code and user 1 can only stop calls to Espload)Until next reportable event (installer code - all communications)

When communicating with Espload, it is impossible to enter programming mode.

PG738EX

- 10 -

The system hardware will recognize the following zone conditions:Note: Keypad zones always use (1K OHM) EOL resistor.

SINGLE ZONE CONNECTIONS

ZONE connection, without EOL resistor (N.C. contacts)address 088, key [MEM] = "on"

key [10] = "off " (reset)key [11] = "off " (reset)

N.C. contacts see Figure 1

ZONE connection, with EOL resistor (N.C. and N.O. contacts)address 088, key [MEM] = "off" (reset)

key [10] = "off " (reset)key [11] = "off " (reset)

N.C. and/or N.O. contacts, see Figure 2

ZONE connection, without EOL resistor, with tamper recognition (N.C. contacts)address 088, key [MEM] = "on"

key [10] = key [11] =

Tamper transmits separate code, see Figure 3

ZONE connection, with EOL resistor, with tamper recognition, and with wire fault (short circuit) recognition (N.C. contacts)address 088, key [MEM] = "off "

key [10] = key [11] =

Tamper/wire fault transmits separate code, see Figure 4

- 11 -

PG738EX

See "Tamper/wire Fault Definitionsand Options"

See "Tamper/wire Fault Definitionsand Options"

ESPRIT 738 EXPRESS CONNECTION DIAGRAMS

ESPRIT 738 EXPRESS WIRING DIAGRAM

BLK

GRN

YEL

RED

To cabinet andgrounding rod

-+

BLACK

Charging and battery test LED(every 60 seconds)

RED

RECHARGEABLEBATTERY

SIREN

BELL

-+

TRANSFO

A.C.POWER

16.5VAC 40VA

Address 100Zone 3 = Fire zone if zonedefinition is "24 hour".

- +

BR

N

GR

Y

RE

D

GR

N

RJ31XCA 38A

BELL OUTPUTwill shut downif currentexceeds 3A.

UL/ULC12VDC / 7AH

UL: K12 model T16 V4OULC: Frost model FTC 1637

AUX POWER 400mA max.250mA max. for 24 hr. standby.

Aux power will shut down if current exceeds 1A.

To connect additional wiring to auxiliary power, usethe red (+) and black (-) keypad connectors.

Caution: Disconnect batterybefore replacing fuse.

"TLM" LED: Short flash = OK OFF = DisabledLong flash = Fault Constant = On Line

UL/ULCWheelock

46T-12

Warning:Disconnecttelephone linebefore servicing.

N.C.N.O. 1KEOL

Ω

PS1

ZONE8 or 9

KEYSWITCH CONNECTION

KEYSWITCHKYPD GRN

KYPD BLK

220Ω

S E C U R I T Y S Y S T E M S

780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (514) 491-2313 http://www.paradox.caParadox Security Systems Graphic Dept

PRINTED IN CANADA

*

N.C.

ZONE8 or 9

N.O.

1KEOL

Ω

*

1KEOL

ΩN.C. N.C.

ZONE 8 ZONE 9

PS1 software versionKeypad software versions prior to

1.14.0 Keypad supervision must be OFF

PS1 software versions onwardKeypad software versions onward

2.04.0 Keypad supervision must be ON

*

(See Address , key )090 [11] [12]

FIRE RESETTo program PGM1 to conduct 4 second smoke detector reset when

and are pressed simultaneously:[ ] [ ]CLEAR ENTER

Address = (first digit)Address =

039 [ ]040 [5] [10]

BYP Address =Address =

042 [2 ] [6]056 [10] [10] [4]

ND

FIRE ALARM ZONE CONNECTIONS* PGM maximum 50mA

Smoke detectorpower supervision

relay, 12VDC

COMSmokedetector

Smokedetector

PGMZ3

AUX+

1KEOL

Ω

+

+

--

Smoke detector must be 4 wire latching -UL Falcon model 5454, ULC BRK 2412.Power supervision relay model MR3-UL.

*

P R DOXRMED RE DY

MAX 5per system

For resistor values,refer to 639/640installation manuals.

Smoke and heat detectors

1KEOL

Ω

N.O. contacts

GROUND START CIRCUIT

RNG

WHT

BLK RED

YEL

MR3-UL

+AUXPGM

WHT

BLK RED

MR3-UL

+AUXPGM

PGM OUTPUT RELAY

YELBRN

COM N.C. N.O.

Four pin connectorcan be used forquick installation ofan Esprit keypad.

Service Keypad

+ AUX - GRN YEL

Warning: Improper connectionmay result in damage to thesystem.

Keyswitch can be used inparallel with keypad (Not onUL systems).

BE

LLR

ELA

YO

PT

ION

RESETJUMPER

DIALER

BATT5 AMP

+

+

+

+

+

SERIALOUTPUT

SERVICEKEYPAD

COMAUX --+

BELLPG1AC PG2N.C. N.0. C CCC1 2 3 4 5 6 7GRN YEL T - 1R - 1 TIPRING

738 EXPRESSESPRIT

PARADOXSECURITY

SYSTEMS

+ +

BATT

KEYPAD639/640

MAX 2 per system

The 640 keypad canbe used with thepanels but will notdisplay correct eventlist codes.

KEYPAD616/626/633

MAX 5 per system