Paramount 72 Filtered Enclosure 6910102 is shown with Flat Work Surface 6935000 and two Base Cabinets 3552702. Inset: Paramount 360 Filtered Enclosure 6910104 is shown with Paramount Electric Hydraulic Lift Base Stand 3781000. The Paramount Hydraulic Lift Base Stand can be lowered so that the Paramount Filtered Enclosure and Stand can pass through an 80" high doorway, ensuring portability for sharing among classrooms and laboratories or for storage.

Upload: buikhue

Post on 26-Apr-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

Paramount 72 Filtered Enclosure 6910102 is shown with Flat Work Surface 6935000 and twoBase Cabinets 3552702.

Inset: Paramount 360 Filtered Enclosure 6910104 is shown with Paramount Electric HydraulicLift Base Stand 3781000. The Paramount Hydraulic Lift Base Stand can be lowered so that theParamount Filtered Enclosure and Stand can pass through an 80" high doorway, ensuringportability for sharing among classrooms and laboratories or for storage.

69

Paramount® Filtered EnclosuresFeatures & Benefits

Paramount Filtered Enclosures are self-contained work stationsthat use carbon filters to rid the laboratory of annoying or unsafeconcentrations of organic solvents, formaldehyde, acid gases orammonia. Unlike traditional fume hoods, they require no ductingand can be moved from lab to lab.

Paramount Duet Filtered Enclosures use both carbon-basedand 99.99% efficient HEPA filters for removing gaseous and partic-ulate contaminants. These enclosures are suited to clean roomand other applications that use chemicals that generate fumes,

vapors and/or particulates yet require ISO Class 5 (formerly Class100) conditions.

Color-Smart Filter Cells used in the Paramount are sold separatelyand come in five types: Ammonia, Acid Gas, Organic, Formaldehydeand HEPA. See page 81 for application discussion and orderinginformation. For technical assistance in determining the right FilterCells for your application, submit the Chemical Usage AssessmentForm available at www.labconco.com/chemical_usage.html orcontact Labconco at 800-821-5525 or 816-333-8811.

Filter clamping mechanismwith gas-assisted lift openseffortlessly and applies uniformpressure across the entire topsurface of the filter cells forleak-proof, one-step filterreplacement from the front ofthe enclosure. Color-Smart FilterCells are sold separately.

Air-mixing rear baffle extendsfilter life, ensures safe and rapidfume removal and distributes aneven concentration of contami-nants to the filters for uniformloading. Paramount 360 FilteredEnclosures have a clear, tem-pered safety glass baffle for 360°of visibility, ideal for training orclassroom demonstrations. Theglass baffle pivots down forcleaning.

Fluorescent lights illuminatethe interior and are replaceablefrom the front.

Audible/visual alarm remindsthe user to check the filtersusing sampling tubes or toreplace the filters. The alarm canbe programmed to alert afterthe blower has run for a presetperiod of time. On models withorganic vapor sensors, thesame alarm activates when highconcentrations of organic vaporsare detected by the sensors.

Convenient utility ports allowpassage of tubing and electricalcords from equipment inside theenclosure through the back forconnection to services.

Single-piece, two-positiontempered safety glass sashis angled to allow closer, morecomfortable viewing withoutglare. Set at 13" sash opening towork surface, face velocity is100 fpm; at 15", velocity is 80fpm. The sash pivots up forloading and cleaning.

Programming touchpad andtwo built-in timers allow theuser to program the filter checkand change times through theLCD. Alert messages appearafter the user-specified numberof hours has elapsed.

LCD message center providescontinuous filter status reportsand displays alarm messages.

Durable construction. Sidesand sash are tempered safetyglass that won’t easily discoloror craze like plastic. The frameis glacier white, dry powderepoxy-coated aluminum.

Roughing prefilters removedust and other particulates,extending the life of the Color-Smart Filter Cells.

CE mark. All 230 volt, 50 Hzmodels conform to the CE(European Community) require-ments for electrical safety andelectromagnetic compatibility.

ETL-listed. Hoods carry theETL mark signifying that theyare certified to UL 3101-1/61010-1and CAN/CSA C22.2 No.1010.1.

Air foil directs airflow into thehood to ensure fume containment.

Built-in blower is quiet, non-sparking and corrosion-resistant.

Fully assembled and pre-wired. Mount the Paramount onexisting cabinetry or accessorywork surface and base, installfilters, plug into an electricaloutlet and it’s ready to use.

Performance tested toASHRAE 110-1995.

Exclusive Feature

70

All models feature:

• Glacier white, dry powder epoxy-coatedaluminum construction.

• 3/16" thick tempered safety glass sides.

• Air-mixing, epoxy-coated steel rear baffle.*

• Two roughing pre-filters.

• Two 1.5" diameter utility ports withplastic plugs.

• Gas-assisted filter clamping mechanism.

• Control panel with LCD for display offilter time elapsed; programmable timerfor audio/visual alarm; ALARM/MUTEswitch with LED indicator; SET FILTERTIME, UP/DOWN, and ENTER program-ming switches; and event timer.

• Built-in, non-sparking motor/blower.

• Pre-wired with two 20-watt fluorescentlights and switches for blower and light.

• Angled 1/4" thick tempered safety glasssash, adjustable to two operating heightpositions (13" and 15" to work surface),pivots to full open position (24.25") forcleaning and transfer of material.

• Face velocity of 100 fpm (236 CFM)when sash opening to work surface is13" and 80 fpm (236 CFM) when sashopening is 15".

• Air sampling syringe for test port.

• Shipped fully assembled.

All models conform tothe following regulationsand standards:

• SEFA 1-2002

• ASHRAE 110-95

• ANSI Z9.5-1993

• UL 3101-1/61010-1

• CAN/CSA C22.2 No. 1010.1

• CE Conformity Marking(230 volt models)

Paramount 360 FilteredEnclosure models feature:• Clear, 3/16" thick tempered safety glass

baffle and back panel. The baffle pivotsdown for cleaning.

Models with vaporsensors feature:• Two vapor sensors for detection of

organic vapors with concentrationsof 50 ppm or greater. One sensoris located in the filter bed andone in the exhaust air stream.Upon detection, the sensorsactivate the audible/visual alarm.

All models require (not included):

• Work Surface and Base.See pages 74-75.

• Color-Smart Filter Cells.See pages 81-82.

• HEPA Color-Smart Filter Cells (forDuet models only). See pages 81-82.

Optional accessories(see page 75):

• Replacement Roughing Prefilters

• Electrostatic Prefilters

• Exhaust Collar Kit (for outside ducting)

Paramount® Filtered Enclosures

Paramount 360 Filtered Enclosure 6910104 is shown with Mobile Base Stand 6910700. Color-SmartFilter Cells and supporting base must be ordered separately.

Exclusive Feature

Contact Labconco at 800-821-5525 or816-333-8811 for application assistance.

* Baffle on Paramount 360 models is tempered safety glass.

12.50"

11.75"

71

Ordering Information & Dimensional DataParamount® Filtered Enclosures

Organic 360 Model Duet ModelNominal Catalog Electrical 8-Foot Power Vapor Clear Requires ShippingWidth Number Requirements Cord & Plug Sensors Back & Baffle HEPA Filters Weight lbs./kg

Models without Organic Sensors

3 Feet 6910100 115 volts, 60 Hz, 3 amps • 290/1326910101* 230 volts, 50 Hz, 1.5 amps no plug 290/1326910104 115 volts, 60 Hz, 3 amps • • 290/1326910105* 230 volts, 50 Hz, 1.5 amps no plug • 290/1326910110 115 volts, 60 Hz, 3 amps • • 290/1326910111* 230 volts, 50 Hz, 1.5 amps no plug • 290/1326910114 115 volts, 60 Hz, 3 amps • • • 290/1326910115* 230 volts, 50 Hz, 1.5 amps no plug • • 290/132

Models with Organic Sensors

6910000† 115 volts, 50 Hz, 3 amps • • 290/1326910001† 230 volts, 50 Hz, 1.5 amps no plug • 290/1326910004† 115 volts, 60 Hz, 3 amps • • • 290/1326910005† 230 volts, 50 Hz, 1.5 amps no plug • • 290/1326910010† 115 volts, 60 Hz, 3 amps • • • 290/1326910011*† 230 volts, 50 Hz, 1.5 amps no plug • • 290/1326910014† 115 volts, 60 Hz, 3 amps • • • • 290/1326910015*† 230 volts, 50 Hz, 1.5 amps no plug • • • 290/132

6930100 Paramount Easy OrderParamount Easy Order includes all the components needed for a complete Paramount Enclosure System— from ceiling to floor.Order just one catalog number, 6930100, and receive the following items:

1. 6910100 Paramount Filtered Enclosure for 115 volts, 60 Hz operation as described below.2. 6910700 Mobile Base Stand as described on page 75.3. 6910400 Organic Color-Smart Filter Cells as described on pages 80-81.

* International electrical configuration† 69100 Series Models are for use when organic vapors are expected to exceed 50 ppm. For applications involving organic vapors with concentrations below 50 ppm, 69101 Series Models are recommended.For help in determining concentration levels for your applications, contact Labconco at 800-821-5525 or 816-333-8811. See pages 80 and 81 for ordering information on Color-Smart Filter Cells.

PARAMOUNT FILTERED ENCLOSURELABCONCO

36"

13" and 15" Sash Opening

30" Viewing Heightto Work Surface

34" Interior29"

Non-DuetModels53.38"

DuetModels56.88"

24.25"

33.75"

FRONT

TOP

SIDE

72

All models feature:• Glacier white, dry powder epoxy-coated

aluminum construction.

• 3/16" thick tempered safety glass sides.

• Air-mixing, epoxy-coated steel rear baffle.*

• Four roughing pre-filters.

• Four 1.5" diameter utility ports withplastic plugs.

• Two gas-assisted filter clamping mechanisms.

• Control panel with LCD for display offilter time elapsed; programmable timerfor audio/visual alarm; ALARM/MUTEswitch with LED indicator; SET FILTERTIME, UP/DOWN, and ENTER program-ming switches; and event timer.

• Two built-in, non-sparkingmotor/blowers.

• Pre-wired with four 20-watt fluorescentlights and switches for blower and light.

• Angled, 1/4" thick tempered safetyglass sash, adjustable to two operatingheight positions (13" and 15" to worksurface), pivots to full open position(24.25") for cleaning and transfer ofmaterial.

• Face velocity of 100 fpm (472 CFM)when sash opening to work surface is13" and 80 fpm (472 CFM) when sashopening is 15".

• Air sampling syringe for test port.

• Shipped fully assembled.

All models conform tothe following regulationsand standards:• SEFA 1-2002

• ASHRAE 110-95

• ANSI Z9.5-1993

• UL 3101-1/61010-1

• CAN/CSA C22.2 No. 1010.1

• CE Conformity Marking (230 volt models)

Paramount 360 FilteredEnclosure models feature:• Clear, 3/16" thick tempered safety

glass baffles and back panel. When setscrews are loosened, the baffles pivotdown for cleaning.

Models with vaporsensors feature:• Two vapor sensors for detection of

organic vapors with concentrationof 50 ppm or greater. One sensor islocated in the filter bed. Upondetection, the vapor sensor acti-vates the audible/visual alarm.A second sensor is located in theexhaust air stream and, upon detection,activates the audible/visual alarm.

All models require (not included):

• Work Surface and Base.See pages 74-75.

• Two sets of Color-Smart Filter Cells.See pages 80-81.

• Two sets of HEPA Color-Smart FilterCells (for Duet models only). Seepages 80-81.

Optional accessories (see page 75):

• Replacement Roughing Prefilters

• Electrostatic Prefilters

• Exhaust Collar Kits (for outside ducting)

Paramount® 72 Filtered Enclosures

Paramount 72 Filtered Enclosure 6910102 is shown with Dished Work Surface 6935000 and two Base Cabinets 3552702.Color-Smart Filtered Cells must be ordered separately.

Exclusive Feature

Contact Labconco at 800-821-5525 or816-333-8811 for application assistance.

* Baffle on Paramount 360 models is tempered safety glass.

12.50"

11.75"

23.50"

PARAMOUNT FILTERED ENCLOSURELABCONCO

13" and 15" Sash Opening

30" Viewing Heightto Work Surface

PARAMOUNT FILTERED ENCLOSURELABCONCO

72"70" Interior 29"

Non-DuetModels53.38"

DuetModels56.88"

24.25"

33.75"

73

Ordering Information & Dimensional DataParamount® 72 Filtered Enclosures

* International electrical configuration† 69100 Series Models are for use when organic vapors are expected to exceed 50 ppm. For applications involving organic vapors with concentrations below 50 ppm, 69101 Series Models are recommended.For help in determining concentration levels for your applications, contact Labconco at 800-821-5525 or 816-333-8811. See pages 80 and 81 for ordering information on Color-Smart Filter Cells.

FRONT

TOP

SIDE

Organic 360 Model Duet ModelNominal Catalog Electrical 8-Foot Power Vapor Clear Requires ShippingWidth Number Requirements Cord & Plug Sensors Back & Baffle HEPA Filters Weight lbs./kg

Models without Organic Sensors

6 Feet 6910102 115 volts, 60 Hz, 6 amps • 580/2646910103* 230 volts, 50 Hz, 3 amps no plug 580/2646910106 115 volts, 60 Hz, 6 amps • • 580/2646910107* 230 volts, 50 Hz, 3 amps no plug • 580/2646910112 115 volts, 60 Hz, 6 amps • • 580/2646910113* 230 volts, 50 Hz, 3 amps no plug • 580/2646910116 115 volts, 60 Hz, 6 amps • • • 580/2646910117* 230 volts, 50 Hz, 3 amps no plug • • 580/264

Models with Organic Sensors

6910002† 115 volts, 50 Hz, 6 amps • • 580/2646910003† 230 volts, 50 Hz, 3 amps no plug • 580/2646910006† 115 volts, 60 Hz, 6 amps • • • 580/2646910007† 230 volts, 50 Hz, 3 amps no plug • • 580/2646910012† 115 volts, 60 Hz, 6 amps • • • 580/2646910013*† 230 volts, 50 Hz, 3 amps no plug • • 580/2646910016† 115 volts, 60 Hz, 6 amps • • • • 580/2646910017*† 230 volts, 50 Hz, 3 amps no plug • • • 580/264

74

Paramount® Electric & Manual Hydraulic Lift Base Stands

Paramount ElectricHydraulic Lift Base Stand3781000 may be loweredto 21.5" high to allow foreasy access to filters.

Paramount ElectricHydraulic Lift Base Stand3781000.

Paramount Base Stands offer both height flexibility and portabilityfor Paramount Filtered Enclosures. The hydraulic lift adjustmentaccommodates persons of different heights and allows for easieraccess to the Paramount Enclosure’s upper chamber for filter test-ing and replacement. Manual and electric hydraulic lift models areoffered. The Stands have a unique low profile, caster-mountingdesign so that the Paramount Filtered Enclosure may be loweredto pass through an 80" high doorway, ensuring portability forsharing among classrooms and laboratories or for storage.

Features (All Models):• Support Paramount Filtered Enclosures.• Support loads up to 1000 pounds.• ADA-compliant.• Durable 1.75" tubular, epoxy-coated steel frame with rear

crossbar supports. Support frame is 2.0" x 3.0" tubular steel.• Attractive glacier white finish complements laboratory

casework and Paramount Filtered Enclosures.• Hydraulic lift legs have infinite adjustment from 21.5" to

33.5" high.• Include four 3" diameter, non-marking polyurethane casters

with bearings for quiet operation.• Include 1" thick gray solid epoxy work surface. Surface is

dished on 3-foot models; flat on 6-foot models.

Features (Electric Hydraulic Lift Models):• Include front-accessible, right-side mounted up/down switch.• Available in two electrical configurations. Models for

115 volts, 60 Hz operation include a 12-foot, 3-wire cord and plug. Models for 230 volt, 50 Hz operation include a 12-foot, 3-wire cord and a NEMA 6-15P plug.*

• Electrical components are UL listed.

Features (Manual Hydraulic Lift Models):• Include front-accessible, right-side mounted hand crank.

Turning the crank clockwise raises the stand; counterclock-wise lowers it. The handle may be folded under, out of the way, when not in use.

Dimensions

A29.3"23.8"

12.8"5.0"

4.4"

10.3"

1.5"

B

21.5" MIN33.5" MAX

FRONT SIDE

ELECTRIC LIFT

10.4"

Nominal Hydraulic Overall Electrical ShippingWidth Catalog # Lift Width x Depth Requirements Weight lbs./kg For Use With:

3 feet 3781000 Electric 36.0" w x 29.0" d 115 volts, 60 Hz, 2.4 amps 200/91 3' Paramount Filtered Enclosure

3 feet 3781001* Electric 36.0" w x 29.0" d 230 volts, 50 Hz, 0.8 amps 200/91 3' Paramount Filtered Enclosure

3 feet 3782000 Manual 36.0" w x 29.0" d not applicable 180/82 3' Paramount Filtered Enclosure

6 feet 3743500 Electric 72.0" w x 29.0" d 115 volts, 60 Hz, 2.4 amps 350/159 6' Paramount Filtered Enclosure

6 feet 3743501* Electric 72.0" w x 29.0" d 230 volts, 50 Hz, 0.8 amps 350/159 6' Paramount Filtered Enclosure

6 feet 3754500 Manual 72.0" w x 29.0" d not applicable 330/150 6' Paramount Filtered Enclosure

3-Foot Models A B

3781000, 3781001, 3782000 36.0" 37.2"

6-Foot Models

3743500, 3743501, 3754500 72.0" 73.2"

Ordering Information

* International electrical configuration. The NEMA 6-15P plug may require replacement with a different plug to match the user’s intended receptacle.

Electric Lift

Manual Lift

FRONT SIDEA29.3"23.8"

5.4"

6.5"

1.5"

B

21.5" MIN33.5" MAX

FRONT SIDE

MANUAL LIFT

10.4"5.0"

FRONT SIDE

FRONT SIDE

75

AccessoriesParamount® Filtered Enclosures

Catalog # Description Dimensions Shipping Weight

6910700 3' Stand with Dished Surface 36" w x 29.25" d x 1" thick 155 lbs. (70 kg)

6934000 6' Stand with Flat Surface 72" w x 29.25" d x 1" thick 265 lbs. (116 kg)

6910600 Dished Work Surface for 3' Paramount Filtered Enclosures

For use on existing cabinetry. Included with Mobile Base Stand 6910700 and Base Cabinet6910800. Gray solid epoxy. 36.00" w x 29.25" d x 1.00" thick. Shipping weight 70 lbs. (32 kg)

6935000 Flat Work Surface for 6' Paramount Filtered Enclosures

For use on existing cabinetry or with 2 each 3552702 Base Cabinets. Included with Mobile BaseStand 6934900. Gray solid epoxy. 72.00" w x 29.25" d x 1.00" thick. Shipping weight 160 lbs. (59 kg)

6910800 Base Cabinet with 3' Dished Work Surface

Epoxy-coated steel cabinet with work surface supports 3' Paramount Filtered Enclosure.Interior shelf stores one set of Filter Cells (not included). Includes four leveling feet and one8" filler panel to increase cabinet depth from 22.00" to 30.00". Cabinet dimensions: 36.00" w x22.00" d x 35.50 - 36.75" high. Work surface dimensions: 36.00" w x 29.25" d x 1.00" thick.Shipping weight 260 lbs. (118 kg)

3552702 Base Cabinet without work surface

Epoxy-coated steel base cabinet. Interior shelf stores one set of Filter Cells (not included).Includes four leveling feet and one 8" filler panel to increase cabinet depth from 22.00" to 30.00".Dimensions: 36.00" w x 22.00" d x 35.50 - 36.75" high. Shipping weight 190 lbs. (86 kg). Ordertwo each 3552702 Base Cabinets and one each 6935000 Flat Work Surface to support Paramount72 Filtered Enclosure.

6911000 Replacement Roughing Prefilters

Remove dust and other particulates, extending the life of Color-Smart Filter Cells. Labconcorecommends replacing prefilters whenever changing Color-Smart Filter Cells. 1 pair.Shipping weight 3 lbs. (1.4 kg)

6912000 Electrostatic Prefilters

Remove aerosols, mist and fine particles, extending the life of Color-Smart Filter Cells. Theseoptional prefilters are used in place of Roughing Prefilters for removal of aerosols. 1 pair.Shipping weight 3 lbs. (1.4 kg)

6910900 Exhaust Collar Kit

Permits connection of the Paramount to 6" diameter PVC duct for optional exhausting to theoutside. Includes 8" x 6" thermoplastic duct reducer and 7" diameter flexible duct connection with2 clamps. Paramount 72 Enclosures require two collars. Remote blower is required. ContactLabconco at 800-821-5525 or 816-333-8811 for blower selection assistance.

Mobile Base Stands

Glacier white epoxy-coated tubular steel frame with 5" diameter, toe-locking casters. Includesolid epoxy work surface. Stand is 37.2" high.

Protector VS Ventilation Station 4864001 is shown with Solid Epoxy Work Surface 4864100and Protector Solvent Storage Cabinet 9902000.

Inset: Protector VS Ventilation Station 4862001 is shown with Solid Epoxy Work Surface4862100, Telescoping Base Stand 3747000 and Protector FilterMate Mobile Station 4870000.

77

Protector®VS™ Ventilation StationsFeatures & Benefits

Tempered safety glass frontsash, sides and top offerexcellent visibility, light andprotection making the VS Stationwell suited for teaching demon-strations. Glass provides betterfire, scratch and corrosionresistance than acrylic.

Sturdy glacier white, drypowder epoxy-coatedaluminum frame providesexcellent stability and bettercorrosion resistance than acrylicmodels. No unreliable plastic-to-plastic bonding is used.

Versatile exhaust openingsallow connection from topor back.

Convenient utility ports allowpassage of tubing and electricalcords from equipment insidethe VS Station through the backfor connection to services.Plastic plugs seal the ports whennot in use.

Epoxy-coated steel baffle’sunique slot pattern providesproper distribution of air beingpulled through the enclosureto ensure uniform face velocityat the front opening andcontainment.

Aerodynamic air foil improvesfume containment by reducingturbulence. Air foil swings upfor cleaning.

10.25" sash opening to thework surface limits exhaustdemand, conserves costly tem-pered air and requires a smallerblower than most fume hoods.

Low profile design requiresless space than most ventilatedenclosures. Overall height isless than 23" (58.4 cm).

“Over-the-top” by-pass offersadditional flow and purging ofvapors through the upper interiorof the enclosure.

Ergonomic angled sash allowsa closer view, reduces glare andprovides a more comfortableoperating position than verticalsashes.

Hinged sash swings up toprovide 19" (48.3 cm) openingfor loading and cleaning.

Lower static pressures allowsmaller blower and quieteroperation.

Performance tested toASHRAE 110-1995.

Protector VS Ventilation Stations are enclosures that provide aneconomical alternative to heavy duty fume hoods. With their lowprofile and clear sides, top and sash, VS Stations are well suitedfor classroom and educational laboratory environments wheresupervision or demonstrations are required. They can also beused as weighing stations, light duty fume hoods, solvent cleaningwork bays, and veterinary pathology and cytology enclosures.Smaller than most fume hoods, VS Stations, in 2', 3' and 4'widths, exhaust less tempered room air than traditional hoods to

conserve energy. They have no switches, wiring or servicefixtures that can add significant costs. Illumination is provided byroom light.

Protector VS Stations may be connected to a remote blowerand exhausted to the outside. When connected to the VS Station,Protector FilterMate Mobile Stations provide an alternative to out-side ducting. With a carbon-based and/or HEPA filter cell installed,the FilterMate rids the work area of fumes and vapors and/or haz-ardous particulates. No outside ducting is required.

Exclusive Feature

TOP

CL

2.25" x 10.00"Exhaust Collar

B

78

Nominal Catalog Total Exhaust CFM and Static Pressure ShippingWidth Number 100 fpm S.P. 80 fpm S.P. 60 fpm S.P. Wt. lbs./kg

2 Feet 4862001 150 .08" 120 .05" 90 .03" 50/28

3 Feet 4863001 230 .15" 185 .10" 140 .06" 75/34

4 Feet 4864001 310 .24" 250 .16" 185 .09" 100/45

All models feature:• By-pass airflow design.

• Pivoting air foil.

• Glacier white, dry powder epoxy-coatedaluminum frame and steel slottedbaffle, plenum and air foil.

• Clear, 3/16" thick, tempered safetyglass sides and top.

• 8° angled, 1/4" thick tempered safetyglass sash that has working heightopening of 10.25" to work surfaceand swings up to 19" for loading andcleaning.

• Two utility ports with plastic plugs.

• Epoxy-coated steel 2.25" x 10" ID topexhaust connection and 6.00" ID backexhaust connection.

All models conform tothe following regulationsand standards:• SEFA 1-2002

• ASHRAE 110-95

• ANSI Z9.5-1993

All models require (not included):

• Work Surface. See page 82.

• Base Stand or Cabinet.See pages 96-106.

If ducting to the outside, allmodels also require (not included):• Remote Blower. See page 82.• Ductwork. See page 82 and back pocket.

If connecting to ProtectorFilterMate Mobile Station, allmodels also require (not included):

• Protector FilterMate Mobile Station.See page 79.

• Color-Smart Filter Cell(s).See pages 80-81.

Protector®VS™ Ventilation Stations

Protector VS VentilationStation 4863001 is shownwith Solid Epoxy WorkSurface 4863100 andTelescoping Base Stand3747001. Blower, ductwork,work surface and base standmust be ordered separately.

Ordering Information

Dimensional Data

CL

6.00" ID ExhaustCollar

9.00"10.25" to

Work Surface

A

B

FRONT

20.50"22.38"

22.75"

28.00"

SIDE

TOP SIDE

FRONT

Model A B

4862001 23.75" 11.88"

4863001 35.75" 17.88"

4864001 47.75" 23.88"

Contact Labconco at 800-821-5525 or816-333-8811 for blower sizing assistance.

79

Protector®FilterMate™ Mobile Stations

Catalog Description 9' Cord ShippingNumber and Plug Weight lbs./kg

4870000 Protector FilterMate Mobile Station, 115 volts, 45/20115 volts, 60 Hz, 2 amps 15 amps

4870001** Protector FilterMate Mobile Station, 230 volts, 45/20230 volts, 50 Hz, 1 amp 10 amps, no plug

All models feature:• Glacier white, dry powder epoxy-coated

steel exterior base with a gray formed-thermoplastic filter housing cover.

• Four 2" diameter hard rubber casters.

• Built-in, non-sparking motor blower.

• Adjustable blower speed control.

• Foot-operated ON/OFF switch attachedto a 4' cord.

• Roughing pre-filter to remove dust andother particulates, extending the life ofthe Color-Smart Filter Cell. The pre-filtermay be omitted when using the HEPAFilter Cell only.

Protector FilterMate Mobile Station 4870000.

Ordering Information

FRONT SIDE

• 8 feet of 5" ID flexible duct; two clamps;and a glacier white, epoxy-coated steeltransition adaptor. Right-angle transi-tion adaptor fits on the Protector VSVentilation Station’s top exhaust open-ing, 2.25" x 10", so that it accepts 5" IDflexible duct.

• Air sampling syringe for test port.

• Thermoplastic 5" OD exhaustconnection.

All models conform tothe following regulationsand standards:• UL 3101-1/61010-1

• CAN/CSA C22.2 No. 1010.1

• CE Conformity Marking (230 volt model)*

All models require (not included):

• Color-Smart Filter Cell(s). See pages 80-81. Depending on the application, oneeach carbon-based or one each HEPAfilter cell is required for operation. Or forcombination gaseous and particulateapplications, one each carbon-based andone each HEPA filter cell are required foroperation. Two each carbon-based ortwo each HEPA filter cells may not beinstalled in the FilterMate at one time.

Optional accessories (see page 82):• Opening Reduction Kit for

3' Protector VS Ventilation Station.ncreases face velocity when carbon-based filter cell is used.

• Replacement Roughing Prefilter.

• Electrostatic Prefilter.

26.75" 17.75"

5.00" OD Exhaust Collar

** International electrical configuration

*pending

Protector VS Protector VS Filter Cell(s) Face Velocity Opening ReductionNominal Width Catalog # Used In FilterMate Range (fpm) Kit Required

2 Feet 4862001 Single Carbon 60-100 N/ASingle HEPA 60-100 N/A

Carbon and HEPA 60-100 N/A

3 Feet 4863001 Single Carbon 60-85 To achieve 100 fpmSingle HEPA 60-100 N/A

Carbon and HEPA 60-75 To achieve 90 fpm

4 Feet 4864001 Single Carbon 50-60 N/ASingle HEPA 60-100 N/A

Carbon and HEPA 50-56 N/A

Dimensional Data

27.88"24.50"23.25"

Carbon/HEPA FilterCarbon Filter OnlyHEPA Filter Only

80

Color-Smart™ Filter Cells

Filter Type All Paramount & FilterMate Models Duet & FilterMate Models FilterMateConfiguration Organic Acid Gases Ammonia Formaldehyde Carbon*/HEPA† HEPA/Carbon*†† HEPA**

Acid pouring and mixing •Asbestos handling •Clean room/critical environment •Combination dry and liquid chemicals •Drug compounding/research • •Endoscopy instrument cleaning •Histology/cytology tissue staining,

•coverslipping

Histology/pathology •Hormone research • •Non-biohazardous microbiologicalsamples with trace chemicals •Particulates in conjunction withchemical agents •Pathology/tissue grossing • •Photo-engraving •Plastics production •Pollen handling •Soldering • •Solvent cleaning •Solvent welding/gluing •Weighing chemical powders • •

* Carbon filter type varies based on application † Carbon-based filter cell is placed below the HEPA filter cell on the Paramount and above the HEPA filter cell on the FilterMate so that gaseous contaminants are removed first. †† HEPA filter cell is placed below the carbon-based filter cell on the Paramount and above the carbon-based filter cell on the FilterMate so that particulate contaminants are removed first.** A single HEPA filter applies to the Protector FilterMate Mobile Station only. A Sealed HEPA Filter Cell is required if particulates captured by the filter are hazardous.

Application Matrix

Color-Smart Ammonia Carbon-Based Filter Cells 6910200.

Color-Smart Filter Cells are engineered tothe National Institute for OccupationalSafety and Health (NIOSH) guidelines forrespirators. Filters are color coded in thesame way as respirator cartridge types forat-a-glance recognition. Four carbon-based Filter Cell types and two HEPA FilterCell types are available:

• Organic Filter Cells, Type AC, are colorcoded black and are suitable for vaporsfrom organic solvents including acetone,ethyl acetate, toluene and xylene.

• Acid Gas Filter Cells, Type ST-1, arecolor coded white and are suitable forfumes from acids including hydrochloric,nitric and sulfuric.

• Formaldehyde Filter Cells, Type CI, arecolor coded drab green and are suitablefor vapors from formaldehyde.

• Ammonia Filter Cells, Type CX, arecolor coded bright green and are suit-able for ammonia and low molecularweight amines.

• HEPA Filter Cells, 99.99% efficient, arecolor coded purple and are suitable forremoving particulates such as powdersand pollen. They should not be usedto capture biohazardous materialsor volatile organic material.

• Sealed HEPA Filter Cells, 99.99%efficient, available only for use withProtector FilterMate Mobile Stations,are color coded purple and are suitablefor removing hazardous particulates

such as drugs and dry chemicals.They include a bag out system for safedisposal of contaminated cells. Theyshould not be used to capturebiohazardous materials or volatileorganic material.

Below is an Application Matrix that pro-vides examples of appropriate uses forColor-Smart Filter Cells expended in theParamount and FilterMate. Whether or notthe Paramount or FilterMate would beappropriate for your application requiresconsideration of factors such as the time-weighted exposure limits of your materials.Using Labconco’s exclusive chemicalassessment program, our technical special-ists can help you determine if the Para-mount Filtered Enclosure or Protector VSVentilation Station with Protector Filter-Mate Mobile Station is the right ventilationproduct for your application and, if so, esti-mate filter life. To begin the process, pleasecomplete the Chemical Usage AssessmentForm available on our website atwww.labconco.com/chemical_usage.htmlor call us at 800-821-5525 or 816-333-8811.

81

Color-Smart™ Filter Cells

Catalog # Description Shipping Wt. lbs./kg

6910200 Ammonia Carbon-Based Filter Cells, Type CX. Color-coded bright green. Each cell contains a minimum 90/41of 26 pounds of impregnated carbon. 1 pair of Filter Cells. Includes 3 contaminant detector tubes.

6910300 Acid Gas Carbon-Based Filter Cells, Type ST-1. Color-coded white. Each cell contains a minimum 90/41of 26 pounds of impregnated carbon. 1 pair of Filter Cells. Includes 3 contaminant detector tubes.

6910400 Organic Carbon-Based Filter Cells, Type AC. Color-coded black. Each cell contains a minimum of 90/4126 pounds of activated carbon. 1 pair of Filter Cells.

6910500 Formaldehyde Carbon-Based Filter Cells, Type CI. Color-coded drab green. Each cell contains a minimum 90/41of 26 pounds of impregnated carbon. 1 pair of Filter Cells. Includes 3 contaminant detector tubes.

6933200 HEPA Filter Cells, 99.99% efficient. Color-coded purple. Suitable for removing 0.3 micron particulates. 1 pair of 90/41Filter Cells. One pair is required for Paramount Duet models and two pairs are required for Paramount Duet 72 models.

Catalog # Description Shipping Wt. lbs./kg

6910201 Ammonia Carbon-Based Filter Cell, Type CX. Color-coded bright green. Contains a minimum of 26 pounds of impregnated carbon. Includes 3 contaminant detector tubes. 45/20

6910301 Acid Gas Carbon-Based Filter Cell, Type ST-1. Color-coded white. Contains a minimum of 26 pounds of impregnated carbon. Includes 3 contaminant detector tubes. 45/20

6910401 Organic Carbon-Based Filter Cell, Type AC. Color-coded black. Contains a minimum of26 pounds of activated carbon. 45/20

6910501 Formaldehyde Carbon-Based Filter Cell, Type CI. Color-coded drab green. Contains a minimum of 26 pounds of impregnated carbon. Includes 3 contaminant detector tubes. 45/20

6933201 HEPA Filter Cell, 99.99% efficient. Color-coded purple. Suitable for removing 0.3 micron particulates. 45/20

6933202 Sealed HEPA Filter Cell, 99.99% efficient. Color-coded purple. Suitable for removing 0.3 micron particulates. Includes bag out system for safe disposal of contaminated filter cell. 45/20

For use with Protector FilterMate Mobile StationsEach Ammonia, Acid Gas and Formaldehyde Filter Cell includesthree sampling tubes that detect a broad range of chemicals spe-cific to the filter type. A color change indicates the presence ofcontaminants. Detector tubes more sensitive to the specific chemi-cal in use may be necessary and are available from laboratorysafety supply distributors. Due to the broad range of possibleorganic chemicals, detector tubes are not included with Organic

Filter Cells; they should be purchased separately to match yourchemical use. Depending on the application, one each carbon-based or one each HEPA filter cell is required for operation. Orfor combination gaseous and particulate applications, one eachcarbon-based and one each HEPA filter cell are required for opera-tion. Two each carbon-based or two each HEPA filter cells maynot be installed in the FilterMate at one time.

For use with Paramount Filtered EnclosuresEach pair of Ammonia, Acid Gas and Formaldehyde Filter Cellsincludes three sampling tubes that detect a broad range of chemicalsspecific to the filter type. A color change indicates the presence ofcontaminants. Detector tubes more sensitive to the specific chemicalin use may be necessary and are available from laboratory safety

supply distributors. Due to the broad range of possible organicchemicals, detector tubes are not included with Organic Filter Cells;they should be purchased separately to suit your application. AllParamount models require one pair and all Paramount 72models require two pairs of carbon-based Filter Cells.

Catalog Description ShippingNumber Weight lbs./kg

6925700 Ammonia Detector Tubes, package of 3. 0.5/0.2

6925800 Acid Gas Detector Tubes, package of 3. 0.5/0.2

6926000 Formaldehyde Detector Tubes, package of 3. 0.5/0.2

Replacement Detector Tubes

82

Accessories Protector®VS Ventilation Stations & Protector® FilterMate™ Mobile Stations

Remote Blowers1/4 hp direct drive motor. Corrosion-resistant epoxy-coated steelhousing and wheel. Blower inlet is 6.00" ID. Outlet dimensions are4.25" x 7.38" OD. See dimensional data on page 90.

4869000 Opening Reduction KitInstalls on 3' Protector VS Ventilation Station toreduce the sash opening height from 9.00" to 7.50".Reducing the sash opening helps to increase facevelocity and is necessary when a single carbon-

based filter or combination carbon-based/HEPA filter is used in theProtector FilterMate Mobile Station. Shipping weight 2 lbs. (0.9 kg)

Solid Epoxy Work SurfacesGray work surfaces are contoured to fit thedimensions of Protector VS Ventilation Stationsand dished to contain spills. Solid epoxy ischemical resistant and fire proof.

Catalog # Nominal Dimensions ShippingWidth Wt. lbs./kg

4862100 2 Feet 24.00" w x 25.50" d x .75" thick 40/18

4863100 3 Feet 36.00" w x 25.50" d x .75" thick 60/27

4864100 4 Feet 48.00" w x 25.50" d x .75" thick 80/36

4868200 Replacement Roughing PrefilterRemoves dust and other particulates, extending the life of Color-SmartFilter Cells. Labconco recommends replacing prefilters wheneverchanging Color-Smart Filter Cells. 1 each. Shipping weight 1.5 lbs. (0.7kg)

Catalog # Description Exhaust ShippingWt. lbs./kg

6940101 Transition Adaptor, 6" diameter From back 2/1round, without damper

6940201 Transition Adaptor, 6" diameter From back 2/1round, with damper

4858200 Transition Adaptor, 2.25" x 10.00" From top 2/1rectangle to 6" diameter round

4861700 Blower Transition Adaptor, From top 3/14.25" x 7.75" rectangle to6" diameter round

4861800 Flexible Duct Connection N/A 5/2for 6" diameter duct

Catalog # Description ShippingWt. lbs./kg

4863500 Remote Blower, 115 volts, 60 Hz, 4.4 amps 35/16

4863501 Remote Blower, 115/230 volts, 50 Hz, 5.6/2.8 amps 35/16

7053501 Explosion-Proof Remote Blower, 40/18115 volts, 60 Hz, 4.4 amps

DuctworkEpoxy-coated steel Adaptors provide easy connection to nominal 6" diame-ter PVC duct. Flexible Duct Connection reduces vibration between theblower and ductwork and includes two clamps. See Ducting Options below.

Zero Pressure Weathercap 4722200

Zero Pressure Weathercap 4722200

Blower Transition Adaptor 4861700 Blower Transition Adaptor

4861700Flexible Duct Connection 4861800 Flexible Duct Connection

486180090° Elbow 4708700

90° Elbow 4708700

Transition Adaptor6940101 or 6940201

Transition Adaptor4858200

Thermoplastic Duct4708600

Thermoplastic Duct4708600

90° Elbow 4708700

RemoteBlower4863500

Remote Blower4863500

Thermoplastic Duct4708600

Ducting Options

(Female Duct Coupling 4708900is not depicted in drawings)

6912001 Electrostatic PrefilterRemoves mist and fine particles, extending the life of Color-Smart FilterCells. These optional prefilters are used in place of Roughing Prefiltersfor removal of aerosols. 1 each. Shipping weight 1.5 lbs. (0.7 kg)

S.P. 0.0" 0.125" 0.25" 0.50" 0.75" 0.87"

CFM 595 560 515 420 300 167

CFM @ Static Pressure –Inches of H2O