PCSHK1531
All rights reserved 09/15 SSc
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of September 2015 but subject to change without notice.
RNQ71MV1Outdoor unitIndoor unit FDMNQ71MV1
RNQ71MY1 RNQ90MV1FDMNQ90MV1
RNQ90MY1 RNQ100MV1FDMNQ100MV1
RNQ100MY1 RNQ125MY1FDMNQ125MV1
RNQ140MY1FDMNQ140MV1
RNQ60MV1 RNQ71MV1RNQ50MV1Outdoor unitIndoor unit
DUCT CONNECTION
LOW STATIC PRESSURE TYPE
MIDDLE STATIC PRESSURE TYPE
FDBNQ50MV1 FDBNQ60MV1 FDBNQ71MV1RNQ71MY1
RNQ71MY1RNQ60MV1RNQ50MV1Outdoor unitIndoor unit
CEILING SUSPENDED TYPE
FHNQ50MV1 FHNQ60MV1 FHNQ71MV1 FHNQ90MV1 FHNQ100MV1 FHNQ140MV1FHNQ125MV1
1 2
7160
RNQ60MV1 RNQ71MV1
50
RNQ50MV1
4025
Outdoor unitIndoor unit
CEILING MOUNTED CASSETTE TYPE
Round Flow
Series
Pair
FCNQ50MV1RNQ40MV1
FCNQ40MV1 FCNQ60MV1 FCNQ71MV1RNQ71MY1
90
RNQ90MV1FCNQ90MV1
RNQ90MY1
100
RNQ100MV1
RNQ71MV1 RNQ90MV1 RNQ100MV1
FCNQ100MV1RNQ100MY1
125
RNQ125MY1FCNQ125MV1
14026,00021,00018,000/17,700*113,0009,200Btu/h 30,000 36,000/35,000*2 42,600/42,000*2,3 48,000
7.66.25.3/5.2*13.82.7kW 8.8 10.6/10.4*2 12.5/12.3*2,3 14.1
RNQ140MY1
RNQ90MY1 RNQ100MY1 RNQ125MY1 RNQ140MY1
FCNQ140MV1
Outdoor unit
OUTDOOR UNIT
P r o d u c t L i n e u p
RNQ40MV1FHNQ40MV1
RNQ40MV1FDBNQ40MV1
RNQ25MV1FDBNQ25MV1
New wide lineup of SkyAir series
Note : *1Applicable to FDBNQ series. *2Applicable to FHNQ series. *3Applicable to FDMNQ series.
RNQ25MV1 RNQ40MV1 RNQ50MV1 RNQ60MV1 RNQ71MV1 RNQ71MY1 RNQ90MV1 RNQ90MY1 RNQ100MV1 RNQ100MY1 RNQ125MY1 RNQ140MY1
Comfort enhanced by Round Flow!
Greater comfort
• Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.
Treated surface
Untreated surface
Grimy surface
Resists soiling
External panels are treated with a coating that repels dirt
Avoids uneven temperature and discomfort caused by drafts
With uniform temperature distribution
360° airflow
To prevent dirt sticking to the external panels, they have been coated with a surface treatment
Because air flows out from corner outlets, comfort spreads more widely
Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean.
Non-flocking flapsPrevents mould and microorganisms growing out of the dust and moisture that adheres to the filters.
Filter has anti-mould and antibacterial treatment
Grime prevention and antibacterial coating: Make cleaning easier
Adapts easily to the installation space
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.
3-way flow L-shaped 2-way flow
Opposite 2-way flow
(E.g., installed in a corner)
(E.g., installed in a long room)
(E.g., installed near a wall)
(E.g., installed in middle of ceiling)
4-way flow also possible.
All-round flow
360° airflow can maintain comfort even if air discharge speed is lower.
Typical flow patterns There are a total of 23 flow patterns.
Velocity decreases by 25% when set temperature is raised 1℃ to 1.5℃.
Room remains comfortable even when set temperature is raised 1℃.
Operation sound increases when using 2-way or 3-way flow.
Enhanced Comfort
Air movement is gentle with Round Flow
Airflow distribution
creates uniform comfort throughout
the space.
Accessory required for indoor unit.Option
CEILING MOUNTED CASSETTE TYPE
FCNQ40/50/60/71/90/100/125/140MV1
Round Flow
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
BRC7F633F
A signal receiver must be added to the indoor unit.
Wireless remote controller is supplied in a set with a signal receiver.
Wireless LCD remote controller
Signal receiver unit (Installed type)
Note: Remote controller cable is not included and must be procured locally.
Note: Remote controller cable is not included and must be procured locally.
Wired LCD remote controller
BRC1C61
3 4
Cassette air conditioner with 360° uniform airflow sets the standardCassette air conditioner with 360° uniform airflow sets the standard
43/32dB(A)FCNQ100M
(220V)
High Low
Sound pressure level
Easier to maintain
With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years
The condition of the drain pan anddrain water can be checked byremoving the drain plug andsuction grille Drain plug
Just open the
suction grille!
Quick and easy to installJust 256 mm high. Installable in tight ceiling spaces (40-71M)
Fine square panels Compact body and quiet operationPanel size is same for all models.It is easy to maintain a neat appearance when multiple units are installed.
Optimal comfort and convenience assured by 2 air discharge modes
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor.
Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.
Two selectable temperature-sensors
Note: 1Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller.
2Closing of the corner discharge outlets is recommended.
Air direction
Auto air direction control
Settable to 5 different levels between 15° and 60°
Settable to 5 different levels between 25° and 60°
Auto-swing between15° and 60°
Auto-swing between25° and 60°
Recommended for shops with light coloured ceilings that
must be kept spotless.Standard position to
prevent draft.
Standard setting1 Setting to prevent soiling of ceiling2 (field setting)
The air direction is set automatically to the memorised position of the previous air direction.
Desired situation
Auto-swing
5-levelsair directionsetting
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.
Suitable for high ceilings
When all round flow is selected, ceilings up to 4.2 m in height can be accommodated. (90M-140M)
Setting SettingStandard
4.2 m3.6
m3.2m
Number of air discharge outlets used
4-wayflow
3-wayflow
2-wayflow
4-wayflow
3-wayflow
2-wayflow
3.1 m3.4 m4.0 m
All round flow
2.7 m3.0 m3.5 m
3.0 m3.3 m3.5 m
3.5 m3.8 m-
3.4 m3.9 m4.5 m
All round flow
3.2 m3.6 m4.2 m
3.6 m4.0 m4.2 m
4.2 m4.2 m-
StandardCeiling height High ceiling
High ceiling
Criteria for ceiling height and number of air discharge outlets
Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting.
90-140M40-71M
(Ceiling height is reference value)
Indoor unitHigh
Sound pressure levelLow
dB(A)
40/50M 31 2860/71M 35 2890/100M 43 32
125M 44 34140M 44 36
Same for all models
950 mm 950 mm
256 mm *1 266 mm *2
*1 298 mm high with 90-140M*2 308 mm high with 90-140M
All models can be installed without using lifter because of the light weight
Drain pump is equipped as standard accessory with 850 mm lift
Transparent drain socket
Since the orientation of the suction grille can be adjusted after installing,the direction of the suction grille lines can be unified when multiple units are installed.
Installable in any direction
Because the drain socket is transparent, after the drain piping has been installed, it is easy to check if the drain come out through the socket.
175 mm
850 mm
5 6
CEILING MOUNTED CASSETTE TYPE Round Flow
DIII-NET communication standardConnection to a centralised control system is available without option.
Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height. Note: If the wireless remote controller is installed, a signal receiver unit is housed in one of the adjuster pockets.
Easy height adjustment
Options required for specific operating environments
Filter chamber (Can be used with ultra long-life filter)
High-efficiency filter
Filter chamber (Can be used with high-efficiency filter)
Ultra long-life filter
High-efficiency filter unitAvailable in two types: 65% and 90% colorimetry.
Please use if you think the temperature and humidity inside the ceiling exceeds 30°C and RH 80%, respectively.
Insulation kit for high humidity
Using this kit, a duct can be fitted to increase the intake of outdoor air.There are two chamber types that have intake in two places: with T-duct joint and without T-duct joint.
Fresh air intake kit
Even in dusty environments where the air conditioning is on most of the time, the ultra long-life filter only has to be cleaned once a year.
Ultra long-life filter unit
Panel spacerUse when only minimal space is available between drop ceilings and ceiling slabs.
Sealing material of air discharge outletSealing material block air discharge openings not used in 2-way or 3-way blow.
Outside
Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit.
40mm
Panel spacer
Branch duct (direct-connection round duct)A round duct can be attached without the need for a chamber.A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole).
Dusty area: annual filter change
Ordinary store or office: filter change every 4 years
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.) 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 12 month/years x 4 years
1 Use of options will increase operating sound.2 Connecting ducts, fan, insect nets, fire dampers, air filters, and other parts
should, as required, be procured locally. 3 When a local-procured fan is used, an interlock with air conditioner is
necessary.Optional PCB(KRP1C63)is required for interlocking.4 It is recommended that the volume of outdoor air introduced through the kit is
limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending.
Note:
The units can be installed in the following different ways.
Intake duct(procured locally)
Direct installation type
Chamber type (with T-duct joint)
KDDP55X160
KDDP55B160K
Chamber type (without T-duct joint) Note 3.4
Note 3.4
KDDP55B160
Intake duct(procured locally)(duct length: 4 m max.)Connection
chamber
Suction chamber
Connection chamber
Suction chamberTop panel insulation(1)
Top panel insulation(2)Top panel insulation(3)Insulation for decoration panelSide panel insulation Suspension bracket insulation
Flexible duct(procured locally)
T-duct joint(procured locally)
Intake duct(procured locally)(duct length: 4 m max.)
Flexible duct
T-duct joint
Duct flange (with insulation material)
Note 1.2
Switchable fan speed: High/Low
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
On/Off timer
(mm)
Uses quiet stream fan and other quiet technologies.
Turbulent flow is reduced
Straightening plate
Quiet stream fan
50°
50/60M 44 4071/90M 45 40
100/125M 48 42140M 49 43
Indoor unitHigh
Sound pressure levelLow
40M 43 39
195960 1,160
680
Height
Indoor unit
WidthDepth
40M 50/60M
1,400 1,590
71/90M 100/125/140M
Quiet operation
Easy maintenanceLong-life filter (standard) requires no maintenance for about 1 year*
* For dust concentration of 0.15 mg/m3
Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the wired remote controller (filter sign).
The filter is washable and reused after 1 year.
Oil resistant grille
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments.
Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments
For all maintenance tasks, access is from bottom surface
It is easy to wipe dirt off the flat side and lower surfaces of the unit.
Easy-clean, flat surfaces
Diffuses comfortable air throughout the room
Installation flexibility for freedom of design
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Programme "Dry"
Auto-swing (up&down) brings comfort to the room
Wide air discharge openings produce a spreading 100° airflow
Air is blown up to 50° in the downward direction
Switchable fan speed: High/Low
Installable on ceilings 3.5 m high
100°
*Water used in the test-run can be drained from the air discharge opening rather than from the side as was formerly the case.
The unit fits more snugly into tight spaces.
Flexible installation
Uniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints
30 mm or more
30 mm or more
(220V) dB(A)
Pipes more easily riggedPlastic panels are used to conceal piping holes.Holes can be easily punched out without requiring special tools.
All wiring and internal servicing can be done from under the unit
Non-flocking flap
Condensation does not easily form on and dirt does not cling to non-flocking flap. It is easy to clean.
Non-flocking flap
CEILING SUSPENDED TYPE
7 8
Comfortable airflow travels throughout the roomComfortable airflow travels throughout the room
Accessory required for indoor unit.Option
FHNQ40/50/60/71/90/100/125/140MV1
45/40dB(A)FHNQ90M
(220V)
High Low
Sound pressure level
BRC7NU66
A signal receiver must be added to the indoor unit.
Note: Remote controller cable is not included and must be procured locally.
Wireless remote controller is supplied in a set with a signal receiver.
Wired LCD remote controller
Wireless LCD remote controller
BRC1NU61
Signal receiver unit (Installed type)
Quiet operation Quiet operation
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Ventilation grille
Door-installedventilation grille
Ventilation grille
Wall-installedventilation grille
Under-door cutout
Under-door cutoutWhen air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Ventilates air through the partitioning wall. (See right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
9 10
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Freedom of layout
Wired LCD remote controller
BRC1C61
Accessory required for indoor unitOption
Switchable fan speed: High/Low
Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening.
The duct system allows the efficient location of discharge outlets in accordance with the room layout
Duct connection is simpler with standard rear suction chambers
Indoor unitHigh Low
60/71M 43 4025/40/50M 41 38
(220V) dB(A)
Indoor unitHigh
Sound pressure level Sound pressure levelLow
90M 44 3671M 42 38
125/140M 46 37100M 45 37
(220V) dB(A)
Wired LCD remote controller
BRC1C61
Accessory required for indoor unitOption
BRC4C64
A signal receiver must be added to the indoor unit.
Wireless remote controller is supplied in a set with a signal receiver.
Wireless LCD remote controller
Signal receiver unit (Separate type)
BRC4C64
A signal receiver must be added to the indoor unit.
Wireless remote controller is supplied in a set with a signal receiver.
Wireless LCD remote controller
Signal receiver unit (Separate type)
FDBNQ25/40/50/60/71MV1 FDMNQ71/90/100/125/140MV1
DUCT CONNECTION LOW STATIC PRESSURE TYPE
45/37dB(A)FDMNQ100M
(220V)
High Low
Sound pressure level
43/40dB(A)FDBNQ71M
(220V)
High Low
Sound pressure level
Ideal for quiet, beautiful living spacesIdeal for quiet, beautiful living spaces Unit can be mounted in the ceiling and air can be delivered freely by ductUnit can be mounted in the ceiling and air can be delivered freely by duct
CompactSmall, lightweight, and easy-to-install indoor unit.
Suction chamberAir filter
(Note)
[Duct connection]
or moreor more To prevent increased operation sound, avoid installing the air suction grille directly below the suction chamber.
Note : 270 mm is the minimum size. Extra height is necessary for drain piping slope and insulation.
Note : 325 mm is the minimum size. Extra height is necessary for drain piping slope and insulation.
Air conditioner305 mm
Ordinary duct (procured locally)
Air discharge Air intake
(Note)or moreor more325 mm325 mm
Ordinary duct (procured locally)
Note: Remote controller cable is not included and must be procured locally.
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable is not included and must be procured locally.
Note: Remote controller cable is not included and must be procured locally.
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable is not included and must be procured locally.
Suitable for condominiums and apartments, houses and hotels
OUTDOOR UNIT
Quiet Operation
To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air.
Fitted with Super Aero Grille
Equipped with scroll compressor for quiet operation
Smooth running, minimal vibration, low operating sound.
Allowed refrigerant piping length and level difference
Max. length
Max. leveldifference
Pre charged1
RNQ25/40M RNQ50/60M RNQ71M RNQ90-140M
10 m
30 m
10 m 15 m 20 m 30 m
30 m(Equivalent length
50m)
50 m(Equivalent length
70m)
15 m
(Applies to RNQ90-140M)
Installation and maintenance
Pre charged for up to 15 mIf refrigerant piping length does not exceed 10m (RNQ25-71M), 15m (RNQ90-140M), there is no need for on-site gas charging.
DurabilityAs the bottom frame is subject to corrosion, corrosion-proof galvarium steel plate is adopted to enhance the durability
Heat exchange fins are provided with anti-corrosion treatment
11 12
RNQ25MV1RNQ40MV1
RNQ50MV1RNQ60MV1
RNQ71MV1RNQ71MY1
RNQ90MV1RNQ90MY1
RNQ100MV1RNQ100MY1RNQ125MY1RNQ140MY1
Operation sound
dB(A)
(Applies to RNQ125-140M)
(Applies to RNQ90-140M)
(Applies to RNQ25-71, 100-140M)
4-direction piping offers greater layout freedomThe outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installation piping work.
(Applies to RNQ90-140M)
Removable part of bottom frame makes the piping work easier (Applies to RNQ90-140M)
Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.
Outdoor unit Sound pressure levelRNQ25MV1 48RNQ40MV1 49RNQ50MV1 51RNQ60MV1 52
RNQ71MV1/RNQ71MY1 54RNQ90MV1/RNQ90MY1 55
RNQ100MV1/RNQ100MY1 54RNQ125MY1 56RNQ140MY1 58
ConstructionNon-treated fin
Anti corrosion treated fin
Aluminium
AluminiumCorrosion resistant resin
Hydrophilic treatment
(In case of RNQ25-60M:220-240 V, RNQ71-100M:220 V/380 V, 240 V/415 V, RNQ125-140M:380 V, 415 V)
Separation available
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, Anti corrosion treated fin for heat exchangers (with special coating) are used for the heat exchanger of the outdoor unit.
Whatever your space, give it the comfort it deserves
REMOTE CONTROLLER Optional accessory
Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.)
Facilitates maintenance and repairAll initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set without having to use stepladder access for manual setting.Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically).
Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction.
SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying interlocking operations.
Easily adaptable to large-scale, high-function, centralised remote control systems.Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.
LCD panel shows operating status in letters, numbers, and motion.Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Programming time display Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
CEILING MOUNTED CASSETTE TYPECEILING SUSPENDED TYPEDUCT CONNECTION LOW STATIC PRESSURE TYPE
BRC7NU66BRC7F633F
BRC4C64DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE BRC4C64
Wired remote controller has built-in temperature-sensor (Applies to wired remote controllers (BRC1C61/1E62))
(Model name display function applies to BRC1E62 only.)
13 14
Navigation Remote Controller(Wired LCD Remote Controller)
Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units. Remote controller options are shown on the page introducing each indoor unit model.
NEW
- 5 actions per day can be scheduled for each day of the week.- The holiday function will disable schedule timer for the days that have been set as holiday.- 3 independent schedules can be set. (e.g. summer, winter, mid-season)
Display is available in 11 languages.
ConvenienceWeekly schedule Multilingual display
(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish).NEW
Clear DisplayDot matrix display Backlight
displayA combination of fine dots enables various icons.Large text display is easy to see.
This simple, modern designed remote controller with fresh white colour matches your interior design. Operation is much easier and smoother, just follow the indications on the navigation remote controller.
Energy savingNEW
- Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.- Period can be preset from 30 to 180 minutes in10-minute increments.
Off timer (programmed)
Setpoint range setNEW Setpoint auto reset
Restaurant sampleRestaurant opened
Temperature is set to 27ºC
27°C
- Saves energy by limiting the min. and max. set temperature.
- Avoids excessive heating or cooling.
- This function is convenient when the remote controller is installed at a place where any number of people may operate it.
- Even if the set temperature is changed, it returns to the preset temperature after a preset period of time.
- Period selectable from 30min/60min/90min/120min.
Full tables at lunchtimeThen is lowered to 24ºC for crowded room
24°C
After 30 minutes*Automatically returns to preset temperature (27ºC)
*Setting possible for after 30, 60, 90, and 120 minutes.
Returns to
27°Cautomatically
Signal receiver unit (For ceiling mounted cassette type)
Wireless remote controller for each indoor unit type
Wireless LCD remote controller
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type.
Wireless remote controller
BRC7F633F
The wireless remote controller is supplied in a set with a signal receiver.Signal receiver unit is contained inside decoration panel or indoor unit.Shape of signal receiver unit differs according to the indoor unit.
The rubber switch and the oil-resistant plastic casing are adopted for durability.Only 17 mm thick. Can be installed either recessed or exposed.
Easy to read because of large LCD screen.Wired LCD remote controller
BRC1C61BRC1E62
FunctionsoverviewFunctionsoverview
FUNCTIONSREMOTE CONTROLLER Optional accessory
Cooling only
15 16
*1 : Applicable when wired remote controller is used*2 : Applicable when BRC1E62 is used*3 : Applicable to RNQ90-140M
*4 : Applicable to RNQ25-71M*5 : For outdoor units*6 : Installable on max. 3.5 m high ceiling
*7 : Applicable when BRC1C61 is used*8 : Option
FCNQ40-140MV1
RNQ40-100MV1RNQ71-140MY1
FHNQ40-140MV1
RNQ40-100MV1RNQ71-140MY1
FDBNQ25-71MV1
RNQ25-71MV1RNQ71MY1
FDMNQ71-140MV1
RNQ71-100MV1RNQ71-140MY1
Indoor unit
Outdoor unit
Comfort
Cleanliness
Remote Controller
Work & servicing
Control features
Options
Others
CEILING SUSPENDED TYPE
DUCT CONNECTIONLOW STATIC PRESSURE TYPE
DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE
CEILING MOUNTED CASSETTE TYPERound Flow
Note:
Auto swing
Swing pattern selection
DC fan mortor (Indoor unit)
Switchable fan speed
Programme “Dry”
High ceiling application
Two selectable temperature-sensors *1
Setpoint auto reset *2
Setpoint range set *2
Weekly schedule timer *2
Off timer (programmed) *2
On/Off timer
Anti-bacterial air filter
Drain pump mechanism
Pre-charged for up to 15 m *3
Pre-charged for up to 10 m *4
Long-life filter
Filter sign
Ceiling soiling prevention
Auto-restart
Control by 2 remote controllers
Group control by 1 remote controller
External command control
Central remote control
Interlock control with Heat Reclaim Ventilator
DIII-NET communication standard
High-efficiency filter
Ultra long-life filter
Fresh air intake kit
Anti corrosion treated heat exchangers *5
*8
*7 *7*7
*6
Central remote controller
Easily adaptable to large-scale, high-function, centralised remote control system.
Centralised control, with setting as simple as it is with a standardremote controller, of up to 64 groups (1,024 indoor units) is possible.
DCS302CA61 (Option)
With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways.
DCS601C51 (Option)
Unified on/off controller
Centralised control of on/off by group or all at once for up to 256 indoor units.
DCS301BA61 (Option)
Schedule timer
Unified control of weekly schedule for up to 1,024 indoor units.
DST301BA61 (Option)
Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time.
System variation to control multiple indoor units
Control by 1remote
controller
Control pattern
Applicable model
FCNQ
FDBNQ
FDMNQ
Wired remote controller Wireless remote controller
Control by 2remote
controllers
Group control
Control by external
command
Centralised remotecontrol
Interlock control
with Heat Reclaim
Ventilator
(Basic system)
Control by 1 wireless remote controller and 1 wired remotecontroller (See note 2, 3)Signal receiver unit installed on indoor unit
Signal receiver unit installed on indoor unit
Can be operated simultaneously or independently by remote controller (set by ventilation mode)
Heat ReclaimVentilator
Non-polar, double-core (max. wiring length 500 m)
Connects 2 wired remote controllers (See note 1)
Automatic address setting function Automatic address setting functionSignal receiver unit installed on 1 indoor unit
Optional wiring adaptor for electrical appendices is necessary
Can be operated simultaneously by remote controller (set by ventilation mode)
Heat ReclaimVentilator
For control from 2 locations such as in room and control room, exits, etc.
For simultaneous control of up to 16 indoor units.
Operation and monitoring is carried out using the contact signal from the operation control box in the monitoring room.
Centralised control of up to 64 indoor groups from remote location up to 1 km away.
Link by remote controller group control.
Zone link control by centralised control.
Optional wiring adaptor for electrical appendices is necessary
Note: 1BRC1E62 can connect to BRC1E62 only. 2It is not possible to use two wireless remote controllers. 3BRC1E62 cannot connect to wireless remote controller.
(Command from outside) (Command from outside)
Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Can also be operated independently by remote controller.
Central remote controller (option)
Heat ReclaimVentilator
Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking
Central remote controller (option)
Heat ReclaimVentilator
Central remote controller (option) Central remote controller (option)
FCNQ only
FCNQ series only
2step 2step2step2step
Work and Servicing
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
Maintenance is not required for one year.The filter is washable and can be reused.
If refrigerant piping length does not exceed 15 m, there is no need for on-site gas charging.
The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
Drain pump mechanism
Long-life filter
Pre charged for up to 15 m
Filter sign
Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.
Ceiling soiling prevention function
RNQ25-71M : 10 m*Applicable to RNQ90-140M.
Others
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, Anti corrosion treated fin for heat exchangers (with special coating) are used for the heat exchanger of the outdoor unit.In high corrosive areas, regular maintenance needs to be carried out.
Anti corrosion treated heat exchangers
You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.)
Group control by 1 remote controller
Control features
If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.
Auto-restart
Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 km away.
Central remote control
Enables interlocking control with external equipment such as Heat Reclaim Ventilator.
Interlock control with Heat Reclaim Ventilator
Standardly equipped interface enables connection to centralised control system without need of an adaptor.
DIII-NET communication standard
Using 2 remote controllers you can operate the equipment locally or from a remote location.Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.
Control by 2 remote controllers
Operation and monitoring is carried out using the contact signal from the operation control box in the building monitoring room.
External command control
*An option is required.
Two types are available: 65% and 90% colorimetry. High-efficiency filter
You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.
Fresh-air intake kit
Options
Ultra long-life filterRequires no maintenance for about 4 years* (10,000h) in stores and offices.*For dust concentration of 0.15 mg/m3
*For dust concentration of 0.15 mg/m3
FUNCTIONS
17 18
Abundance of functions that provide comfortable air-conditioning in stores and offices.
Cleanliness
The air filter has an anti-bacterial treatment to help prevent the growth of bacteria and mould on it.Anti-bacterial air filter
Note: Some functions only available on selected models. See overview page for full list of features applicable to each unit.
Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.
Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.
High-ceiling application
High setting provides maximum reach while low setting minimises drafts.
Switchable fan speed
DC fan motor improves efficiency.DC fan motor (indoor unit)
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room.
Programme "Dry"
Comfort
Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner.
Auto-swingThe air flow direction can be fixed at your desired angle by the remote controller.
Note: Wireless remote controllers have no temperature-sensor.
Use the temperature-sensor in the indoor unit when controlling air conditioning from another room.
Two selectable temperature-sensorsTemperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level.
Remote Controller
Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.
Off timer (programmed)
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
On/Off timer
Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature.
Weekly schedule timer
Even if the set temperature is changed, it returns to the preset temperature after a preset period of time.
Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling.
Setpoint auto reset
Setpoint range set
(1) Standard setting
(2) Ceiling soiling prevention setting
(standard, ceiling soiling prevention)You can freely set 2 air discharge setting by remote controller.
Swing pattern selection
CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
DUCT CONNECTION LOW STATIC PRESSURE TYPE
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
SPECIFICATIONS
43/39
24
White
VP20 (I.Do/ 20XO.Do/ 26)
19.4 to 46o/ 6.4
49
36 40 49--------- --------- ---------
1.2 (Charged for 10 m)
0.9
51
1.4 (Charged for 10 m)
1.4
52
1.5 (Charged for 10 m)
1.82.0
(Charged for 10 m)
2.21.9
(Charged for 15 m)3.2
(Charged for 15 m)
2.72.7
(Charged for 15 m)
3.753.2
(Charged for 15 m)
4.5
Ivory white
30
10 15
Hermetically sealed rotary type
o/ 12.7 o/ 15.9
o/ 18.0 (Hole)
°CWB
°CDBCertified operation range
Certified operation range
Motor outputCompressor
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A) kg
dB(A)Sound pressure level3Dimensions (HXWXD) mmMachine weight kg
kgV1Y1
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H/L) m3/min 16/-565/-
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length m
mMax. installation level difference
Type
Sound pressure level (H/L) (220 V)3
Indoorunit
Both liquid and gas piping
cfm
14 to 23 14 to 25
19 20
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
°CDBCertified Operation range
Sound pressure level3
°CWBCertified Operation range
Motor outputCompressor
Dimensions(HXWXD)
Colour
mmmm
dB(A)
kWRefrigerant charge (R-410A) kg
dB(A)Dimensions (HXWXD) mmMachine weight kgV1
Y1
Unit
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weight kg
kgUnitDecoration panel
Airflow rate (H/L) m3/mincfm
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length m
mMax. installation level difference
Type
Sound pressure level (H/L)3
Indoorunit
Hermetically sealed rotary type Hermetically sealed scroll type
o/ 6.4o/ 15.9o/ 12.7
50X950X950
5.5
----------
10 15 20 30
Ivory white
Fresh white
Both liquid and gas piping
30 30 (Equivalent length 50)
30 (Equivalent length 50)
50 (Equivalent length 70)
o/ 26.0 (Hole)o/ 18.0 (Hole)VP25 (I.Do/ 25XO.Do/ 32)
19.4 to 46o/ 9.5
21 to 46
14 to 23 14 to 25
0.9 1.4 1.8 2.2 2.7 3.75 4.5
31/28 35/28 43/32 44/34 44/36
49 51 52 54 55 54 56 58
36 40 49 56 77 99 --------- ------------------ --------- --------- 56 74 99 107 111
19.5 21 24
256X840X840 298X840X840
1.2(Charged for 10 m)
1.4(Charged for 10 m)
1.5(Charged for 10 m)
2.0(Charged for 10 m)
1.9(Charged for 15 m)
3.2(Charged for 15 m)
2.7(Charged for 15 m)
3.2(Charged for 15 m)
13/10 21/13.5 32/20 33/22.5459/353 741/477 1,130/706 1,165/794
Cooling capacity1,2 kWY1V1Y1V1
kWPower consumption
ModelName
Indoor unit
Power supply
Cooling1 Btu/h
W/WCOP
40FCNQ40MV1RNQ40MV1
3.813,000
550X765X285
1.243.07
50FCNQ50MV1RNQ50MV1
5.318,000
595X845X300
1.892.80 2.80
60FCNQ60MV1RNQ60MV1
--------- --------- ---------
6.221,0002.21
71FCNQ71MV1RNQ71MV1
7.626,000
735X825X300
735X825X300
2.533.00
90FCNQ90MV1RNQ90MV1
8.830,000
990X940X320
2.733.22
100FCNQ100MV1RNQ100MV1
RNQ71MY1
71FHNQ71MV1RNQ71MV1RNQ71MY1
RNQ90MY1 RNQ100MY1
10.636,000
1,345X900X320
3.313.20
125FCNQ125MV1
---------
12.542,6004.153.01
140FCNQ140MV1
---------RNQ125MY1 RNQ140MY1
14.148,0005.042.80
1 Phase, 220–240 V, 50 Hz---------
---------3 Phase, 380–415 V, 50 Hz
Hermetically sealed scroll type
o/ 9.5
o/ 26.0 (Hole)50
(Equivalent length 70)30
21 to 46
45/40 48/42 49/43
5554 54 56 58
7756 99 --------- ---------7456
20
99 107 111
195X1,590X680
26-27/22-23 38-40/23-25918-953/777-812 1,341-1,412/812-883
90FHNQ90MV1RNQ90MV1
8.830,000
990X940X320
3.072.87
7.626,0002.65
100FHNQ100MV1RNQ100MV1
RNQ90MY1 RNQ100MY1
10.435,000
1,345X900X320
3.642.86
125FHNQ125MV1
---------
12.342,0004.512.73
140FHNQ140MV1
---------RNQ125MY1 RNQ140MY1
14.148,0005.512.56
42-44/24-261,483-1,553/847-918
---------3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
Cooling capacity1,2 kWY1V1Y1V1
kWPower consumption
ModelName
Indoor unit
Power supply
Cooling1 Btu/h
W/WCOP
40FHNQ40MV1RNQ40MV1
195X960X680
3.813,000
550X765X285
1.582.40
50FHNQ50MV1RNQ50MV1
195X1,160X680 195X1,400X68026 32 35
44/40777-812/671-706
22-23/19-20
5.318,000
595X845X300
2.042.60 2.60
60FHNQ60MV1RNQ60MV1
--------- --------- ---------
6.221,0002.38
1 Phase, 220–240 V, 50 Hz---------
Outdoor unit
Outdoor unit
°CDB
°CWBCertified Operation range
Certified Operation range
Motor outputCompressor
Indoorunit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A)Sound pressure level4
Sound pressure level (H/L) (220 V)4
dB(A)Dimensions (HXWXD) mmMachine weight kgV1
Y1
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate (H/L)3Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length m
mMax. installation level difference
Type
----------
Both liquid and gas piping
mmOutdoor unit
Ivory white
mmH2Ocfm
Rated external static pressure3
10 15 20
19.4 to 46 21 to 46
14 to 23 14 to 25
m3/min
30 30 (Equivalent length 50 m)
3/4B (I.Do/ 21.6XO.Do/ 27.2)
o/ 6.4 o/ 9.5o/ 12.7o/ 9.5 o/ 15.9
o/ 18.0 (Hole)
0.65 0.9 1.4 1.8 2.2
25 32
35 36 40 49 56---------- ---------- ---------- ---------- 56
Hermetically sealed rotary type
0.9 (Charged for 10 m)
1.2 (Charged for 10 m)
1.4 (Charged for 10 m)
1.5 (Charged for 10 m)
2.0 (Charged for 10 m)
459/38813/11
635/53018/15
41/38 43/40
48 49 51 52 54
2.0
Y1V1Y1V1
Cooling capacity1,2 kW
kWPower consumption
ModelName
Indoor unit
Power supply
Cooling1 Btu/h
W/WCOP
25FDBNQ25MV1
RNQ25MV1
260X900X580
2.79,200
550X765X285
0.863.14
40FDBNQ40MV1
RNQ40MV1
3.813,0001.282.97
50FDBNQ50MV1
RNQ50MV1
5.217,700
595X845X300
2.062.52
60FDBNQ60MV1
RNQ60MV1
260X1,300X580
6.221,000
2.382.60
71FDBNQ71MV1
RNQ71MV1--------- --------- --------- --------- RNQ71MY1
7.626,000
735X825X300
2.622.90
1 Phase, 220–240 V, 50 Hz--------- 3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Please see fan characteristic document in detail.4Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
°CDB
°CWBCertified Operation range
Certified Operation range
Motor outputCompressor
Indoorunit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A)Sound pressure level4
Sound pressure level (H/L) (220 V)4
dB(A)Dimensions (HXWXD) mmMachine weight kgV1
Y1
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate (H)3Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length m
mMax. installation level difference
Type
----------
Both liquid and gas piping
mmOutdoor unit
Ivory white
mmH2Ocfm
Rated external static pressure3
20 30
21 to 46
14 to 25
m3/min
30 (Equivalent length 50 m)
50 (Equivalent length 70 m)
3/4B (I.Do/ 21.6XO.Do/ 27.2)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)o/ 18.0 (Hole)
2.2 2.7 3.75 4.5
43 52
56 77 99 ---------- ----------56 74 99 107 111
Hermetically sealed rotary type Hermetically sealed scroll type
2.0 (Charged for 10 m)
1.9 (Charged for 15 m)
3.2 (Charged for 15 m)
2.7 (Charged for 15 m)
3.2 (Charged for 15 m)
81223
1,30637
1,48342
42/38 44/36 45/37 46/37
54 55 54 56 58
8.5 9.8 8.0
Y1V1Y1V1
Cooling capacity1,2 kW
kWPower consumption
ModelName
Indoor unit
Power supply
Cooling1 Btu/h
W/WCOP
71FDMNQ71MV1
RNQ71MV1
305X1,350X680
7.626,000
735X825X300
2.622.90 2.90
90FDMNQ90MV1
RNQ90MV1
305X1,550X680
8.830,000
990X940X320
3.03
100FDMNQ100MV1
RNQ100MV1
10.636,0003.533.00
1,345X900X320
125FDMNQ125MV1
---------
12.342,000
4.492.74
140FDMNQ140MV1
---------RNQ71MY1 RNQ90MY1 RNQ100MY1 RNQ125MY1 RNQ140MY1
14.148,000
5.562.54
1 Phase, 220–240 V, 50 Hz ---------3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
Round flow type: List of optional parts required to achieve different flow patterns
1In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.3It is not possible to use panel spacers in a 2-way flow installation. 4It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
Panel/grille relatedIndependently installable optional parts
Operation control relatedAuxillary function related
Filter related
Optional accessory parts
Independently installable optional partsOptional accessory parts
Independently installable optional partsOptional accessory parts
Panel spacer1
Panel spacer1 o o ox oWireless remote controller o o oo o
Fresh air intake kit (direct mount) o o oo ox o o
xx
High-efficiency filter2
Filter related Ultra-long-life filter2
o o ox
xUltra-long-life filter2 o o o xx
High-humidity operation kit
Panel/grille relatedOperation control relatedAuxillary function related
Panel spacer1
Wireless remote controller
Fresh air intake kit (direct mount)High-humidity operation kit
All round flow 4-way flow
o3 o3 xx o3
o3 o
x
xxo o
o3 o xx
o ox o o x
o3 o o xx
3-way flow 2-way flow
1-way branch / unit 3-way flowBranch duct1(Chamber type)(Round duct type)
o o o4 xx o2-way branch / unit 2-way flow1-way branch / unit 2-way flow
x o o4 xx ox o o4 xx o
Branch duct connection
Wireless remote controller
Fresh air intake kit (direct mount)
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
Panel spacer1 Wireless remote controller
Fresh air intake kit (direct mount)
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
Panel spacer1 Wireless remote controller
Fresh air intake kit (direct mount)
Fresh air intake kit (Chamber type)1,2 o o ox o
Fresh air intake kit (Chamber type)1,2 o3 o xx o
oo
xoo
o3
o
x
x
x
o
o o o
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (Chamber type)1,2
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
21 22
Indoor unit Indoor unit
Outdoor unitKit name
RNQ50MV1 RNQ60MV1RNQ25MV1 RNQ40MV1 RNQ71MV1 RNQ90MV1 RNQ100MV1 ------- -------------- -------------- ------- RNQ71MY1 RNQ90MY1 RNQ100MY1 RNQ125MY1 RNQ140MY1
Central drain plug
Name of option
KKPJ5F180-------------- KKP014A4
intelligent Touch Controller4
Note: 1Refer to page 6 for the details.2Required for installing high-efficiency filter and ultra long-life filter unit. 3Wiring for wired remote controller to be procured locally.4The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5Installation box for adaptor PCB (KRP1H98) is necessary.
Note: 1Wiring for wired remote controller to be procured locally.
Kit nameFCNQ60MV1 FCNQ71MV1 FCNQ90MV1FCNQ40MV1 FCNQ50MV1 FCNQ100MV1 FCNQ125MV1 FCNQ140MV1Name of option Remark
Chamber type
Decoration panel
Fresh air intake kit1
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Adaptor for wiring5
Without T-duct jointWith T-duct joint
Direct installation type
Sealing material of air discharge outletPanel spacer
Chamber connection kit2Insulation kit for high humidity
Wiring adaptor for electrical appendices(2)5
Installation box for adaptor PCB
High-efficiency filter unit(including filter chamber)
Filter chamber Replacement long-life filterUltra long-life filter unit (including filter chamber)Replacement ultra long-life filter
(Colorimetric method 65%)(Colorimetric method 90%)
Replacement high-efficiency filter
(Colorimetric method 65%)(Colorimetric method 90%)
Remote controller Wireless type Cooling onlyWired type3
Branch duct chamber
Remote sensor (for indoor temperature)
CEILING MOUNTED CASSETTE TYPEKit name
KHFJ5F50
BRC1NU61BRC7NU66
KAF501DA56KHFJ5F60 KHFP5MA160
KAF501DA80 KAF501DA112 KAF501DA160FHNQ60MV1 FHNQ71MV1 FHNQ90MV1 FHNQ100MV1 FHNQ125MV1 FHNQ140MV1FHNQ40MV1 FHNQ50MV1Name of option Remark
Replacement long-life filterL-type piping kit (for upward direction)Remote controller
Wired type1Wireless type
CEILING SUSPENDED TYPE
Note: 1Wiring for wired remote controller to be procured locally.
Kit name
BRC1C61BRC4C64
FDBNQ50MV1FDBNQ25MV1 FDBNQ40MV1 FDBNQ60MV1 FDBNQ71MV1Name of option Remark
Remote controllerWired type1Wireless type
DUCT CONNECTION LOW STATIC PRESSURE TYPE
Note: 1Wiring for wired remote controller to be procured locally.
Kit name
BRC1C61BRC4C64
FDMNQ100MV1FDMNQ71MV1 FDMNQ90MV1 FDMNQ125MV1 FDMNQ140MV1Name of option Remark
Remote controllerWired type1Wireless type
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Navigation Remote Controller Wired type3
BRC1E62Navigation Remote Controller Wired type1
BRC1E62Navigation Remote Controller Wired type1
DCS601C51
DCS302CA61DCS301BA61DST301BA61
KRP1C63
KDDFP55B160
KDBH55K160FKDBP55H160FA
KKSJ55KA160
KDDP55B160KDDP55B160KKDDP55X160
KRP4AA53
KAFP551K160
KAFP556B80KAFP557B80KAFP552B80
KDTP55K80
KDJP55B160KDJP55B80
BRC7F633FBRC1C61
KAFP553B80
KDTP55K160
KAFP556B160KAFP557B160KAFP552B160KAFP553B160
BYCP125K-W1
KRP1H98
KAFP55B160KAFP55H160H
KRCS01-4B
BRC1E62
OPTIONS
4
155
11
o/ 45
4090
5 80
1455
195
30 or more 30 or more
4-M8~M10Hanging bolt
(Service space)(Service space)
1
B
127
8
10
1718
(Han
ging
p
ositi
on)
(Hanging position)A
16
210
36
170
58
19285 160
105
102
14290
185
260
4170
7
225
Drain pipe connection VP206
275
Brand name plateThe Front
(Note.2)
80
275
105
(For left piping)
300
3 2 5
80
6
(Requi
red sp
ace)
Obstacle
680
Floor side
515
5
55
(Req
uire
d sp
ace)
300 o
r more13
For h
eight
instal
lation
From t
he floo
r side
2500 o
r more
10515 (R
equi
red
spac
e)13
55
Position : Hole of wall for taking out in piping back(View from the front)
6550
135
1459 60
65
12
40 60
6011
5
Position slit hole for taking out in piping back(View from the front)
23 24
CEILING SUSPENDED TYPE
236
3×P.150=45016
260
16
151 704
10
688
150
900
127
(All Around)
219
1012-M4 Holes
52
674
5
7
4
6
664
170110
684
260
(All Around)1
228
3×P150=450
50010-M4 Holes16
4
2
29
50
134
107
10 o
r mor
e
300 or more
317
3
704
500
167
580
151
1268
271
(Suspension bolt pinch)
3
55(S
uspe
nsio
n bo
lt pi
nch)
755
137
900
Service space
DUCT CONNECTION LOW STATIC PRESSURE TYPE
A B
[FHNQ40/50/60/71/90/100/125/140MV1]
[FDBNQ25/40/50MV1]
123456789101112131415161718
Air discharge grilleAir suction grilleAir filterGas pipe connectionLiquid pipe connectionDrain pipe connectionEarth terminal (Inside the electric components box)Suspension bracketBackward pipe and wiring connection opening lidUpward pipe and wiring connection opening lidRight side pipe connectionLeft back drain pipe connectionLeft side drain pipe connectionRight side drain pipe connectionHole of wall for taking out in pipe backUpward drain pipe connectionUpward gas pipe connectionUpward liquid pipe connection
Notes:1Location of unit's Name plate : Bottom of fan housing inside the suction grille.2In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.3The remote control code is the standard <about 3m outside the machine> attached.(0.5mm2x2 wicks O.D. 5.4)(It is not attached to VRV.)
Note: 1Location of unit's Name Plate: Chamber cap
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
920 9601120 11601120 1160
FHNQ40MV1FHNQ50MV1FHNQ60MV1
1360 1400FHNQ71MV11360 1400FHNQ90MV11550 1590FHNQ100MV11550 1590FHNQ125MV11550 1590FHNQ140MV1
CEILING MOUNTED CASSETTE TYPE
Notes:1Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface2In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.
3When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.5Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
[FCNQ40-140MV1] [FCNQ40-140MV1]
[FCNQ40-71MV1] [FCNQ40-71MV1]
[FCNQ40-71MV1]
[FCNQ40-71MV1] [FCNQ90-140MV1]
[FCNQ90-140MV1]
[FCNQ90-140MV1] [FCNQ90-140MV1]
7
6
950
8950
Pipe ConnectionSide
Drain ConnectionSide
Note 2
A arrow view
9
C
B
420
710(Hanging bolt pitch)420
860~910(Ceiling opening space) (Note 4)
860~
910(C
eiling
open
ing sp
ace) (N
ote 4)
780(
Han
ging
bol
t pitc
h)95
330
165
Connection positionof branch duct
160
20
16-M4 Prepared hole
50
350
12480
175
125
2
(square-shaped type)
4 1157
246
55
4-M8~M10
2x100=200 80
124
10
Hanging bolt
Connection positionof branch duct
C/L
110
(round shape type)
84055
280
256
40
Adjus
table(
0~67
5)
340
850
Connection positionof branch duct
1500
or m
ore
Connection positionof branch duct
20-M4 Prepared hole
60
From th
e floor s
ide 250
0 or mo
re
130
124
2x100=200
35 or less (Note 4)
55
A
150
84055
160
157256
105
(square-shaped type)
For h
eight
instal
lation
42
(requ
ired s
pace
)
(Note 4)95
3 85124
35 or less
5
(round shape type)
64
350
81
11050
124
81 2x100=200
350
Connection positionof branch duct
160
16-M4 Hole
B arrow view
(round shape type)
110
C/L124
85
157
(square-shaped type)
95
Connection positionof branch duct
80
157
213
95
160
Connection positionof fresh air intake kit
(square-shaped type)
C arrow view
(knock hole)90(round shape type)
124
183
109
25
C/L
124
802x1
00=200
(direct installation type)
ø100
20-M4Prepared hole
Connection positionof branch duct
Connection positionof branch duct
90
350
157
93
2x100=200 85
67
Connection positionof branch duct
C/L(round shape type)160
Connection positionof branch duct
16-M4 Hole
167
(square-shaped type)B arrow view
160
95
81
350
29
213
29
350
80
160
ø100
Connection positionof fresh air intake kit
C/L 157
90
(direct installation type)
67
(knock hole)
Connection positionof branch duct
C arrow view
Connection positionof branch duct
2x100=
200
(round shape type)
(square-shaped type)
196
93
90
8025
95
160
20-M4Prepared hole
167
280
5028
8
80
167
95
157
340840
16510
4Hanging bolt
1
175
55
4-M8~M10Connection positionof branch duct(round shape type)
Connection positionof branch duct
2
40
80
160
2x100=200
125
(square-shaped type)
C/L
298
20
350
850
Adjus
table(
0~67
5) 55
29
330
160
16-M4 Prepared hole
160
1500
or m
ore
81
93
157
130
Connection positionof branch duct
160
2x100=200
A
55
(square-shaped type)
From th
e floor s
ide 250
0 or mo
re
(Note 4)
67
105
For h
eight
instal
lation
85
150
(requ
ired s
pace
)
350
42
29
64
(round shape type)
27-M4 Prepared hole
60
35 or less (Note 4)
35 or less
3
Connection positionof branch duct
256
160 5
95
50
84055
167
The necessary space is 500mm or more when the air-outlet is blocked with the accessory.Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more.
1500mm or more200mm or more
1500mm or more
1500mm or more1500mm
or more200mmor more
Required space
300 or less
Liquid pipe connectionGas pipe connectionDrain pipe connectionPower-source wiring and a unit wiring connectionConnection wiring/remote control wiring connectionAir-outletSuction grilleCorner decoration coverDrain hose (accessory)
1234
5
6789
DIMENSIONS (Unit: mm)
OUTDOOR UNIT // RNQ25/40MV1
25 26
22
50
100
50
150 50
50 300
150
100
285 8
Handle
Wall height on air outlet side =less than 1200Minimum space for air passage
105.5
13
311
490574
29.5
Drain outlet(I.D. 15.9 hose for connection)
4-Hole for anchor bolts (M8 or M10)
550
12 63765Brand name label
Manufacture’s label
196
165
105
Wiring inlet
Gas stop valve( 15.9CuT for RNQ13)( 9.5CuT for RNQ09)
Service port
In case of removing stop valve cover
Liquid stop valve( 6.4CuT)
300 or more
13531337
151
74 1626
3
7×P150=1050
1550
(All Around)
51
20-M4 Holes
8
10
16
305
150
280
1321
5012
3
1314
175
305
18-M4 Holes
212
206
(All Around)
152
827
274
1334
7×P150=1050 2
129 76
5
4
1353
146
3
151
600
116
(Sus
pens
ion
bolt
pinc
h)
381
3
1403
1550
(Suspension bolt pinch)126
55
427
8
680
Service space
[FDMNQ90/100/125/140MV1]
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Note: 1Location of unit's Name Plate: Chamber cap
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
300 or more
7×P150=1050
263
151
20-M4 Holes
51
1350
1137
16
1121
8
10
305
(All Around)
16
150
74
280
1153
7
5
6
4
11141134
129
5012
3
18-M4 Holes
152
206
274
175
2
305
(All Around)727
212
7×P150=1050
126
600
1350
8
116
1153
680
3
381
3
(Suspension bolt pinch)
146
1203
151
427
(Sus
pens
ion
bolt
pinc
h)55
Service space
Service space
300 or more
260
10
236
16
151
102
1300
219
1104
1074
1088
18-M4 Holes
16
(All Around)
52 10
150
6×P.150=900
700
50
16-M4 Holes 29
26×P150=900
164
134
1064
(All Around)
170
260
228
107
1084
1
110 5
6
4
7
10 o
r mor
e
271
317
500
167
580
137
(Sus
pens
ion
bolt
pinc
h)(Suspension bolt pinch)
3
1300
151
551155 1268
31104
[FDBNQ60/71MV1]
[FDMNQ71MV1]
DUCT CONNECTION LOW STATIC PRESSURE TYPE
Note: 1Location of unit's Name Plate: Chamber cap
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Note: 1Location of unit's Name Plate: Chamber cap
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
DIMENSIONS (Unit: mm)
OUTDOOR UNIT // RNQ90MV1, RNQ90MY1
OUTDOOR UNIT // RNQ100MV1, RNQ100/125/140MY1
OUTDOOR UNIT // RNQ50/60MV1
OUTDOOR UNIT // RNQ71MV1, RNQ71MY1
27 28
30
620
91
160
3030
Hole for anchor bolt 4-M12
55
(345~
355)
37
320
160
350
38
145
5
84
53
7
95
6
80
55
19
416
68
161
595
61
16
260
262
36
279
285
8 90
16
5
95
13
53
5
5522
3
6
7
67
52
339
89
95
19
2
5
3
6
4
990
142
34060
89
1
940
7
53
30
8019
84
6
5
55
95
145
54
7
24
1
95
2
19
142
54
7
89
900
6
60
1345
435
410
5
4
3
89
71 1670
45
58
5
102
191
16
376
811
7
48
30
140
3061
96
320
140
350
(345
~355
)
Hole for anchor bolt 4-M12
620
41
53
13
95
52
5522
3
5
67
12345678
Gas pipe connectionLiquid pipe connectionService port (in the unit)Grounding terminalRefrigerant piping intakePower supply wiring intakeControl wiring intakeDrain pipe connection
Gas pipe connectionLiquid pipe connectionService portGrounding terminalRefrigerant piping intakePower supply wiring intakeControl wiring intakeDrain pipe connection
12345678
50
50
300 30
0
50 300
150
50
100
20
845
573.5
20
131
734
2
300
78
326
300
Drain outletI.D. 18 hose for connection
4-Hole for anchor bolts (M8 or M10)
595
Brand name labelWiring inlet
Name plate
105
144
60
Earth terminal in switch box
Gas stop valve( 15.9CuT for RNQ21MV1)( 12.7CuT for RNQ18MV1)
Liquid stop valve( 6.4CuT)
Service port
Wall height on air outlet side =less than 1000Minimum space for air passage
325
36
350
78
580
330
825
2510
300
2124
Drain outletI.D. 15.9 hose for connection
4-Hole for anchor bolts (M8 or M10)
735
Brand name label Wiring inletName plate
3018
64
155160
89
Earth terminal in switch box
Gas stop valve( 15.9CuT)
Liquid stop valve( 9.5CuT)
Service port
350
100
50
100
100
50
350
50
350
Wall height on air outlet side =less than 1200Minimum space for air passage
DIMENSIONS (Unit: mm)
29 30
1000 or more
100 or more 100 or more
1000
or more
300
or more
L H
L H
100 or more 100 or more
300 or more
1000 or more
200 or more
100 or more 100 or more
500 or less
1000 or more
1000
or m
ore
An obstruction in the overhead space
100 or more
100 or more
300 or more
1000 or more
200 or more
500 or less
1000
or m
ore
An obstruction in the overhead space
100 or more
100 or more
When there is an obstruction on the inlet side
When there are obstructions on the inlet side and both sides
2. For multiple units installation (more than two units)
When there are obstructions on both sides
1) When the overhead space is open
1. For single unit installation
When there is an obstruction only on the inlet side
2) When there is an obstruction in the overhead space
1) When the overhead space is open
When there are obstructions on both sides
2) When there is an obstruction in the overhead space
When there is an obstruction on the inlet side
When there are obstructions on the inlet side and both sides
2. For multiple units installation (more than two units)
1. For single unit installation
1. For single unit installation
2. For multiple units installation (more than two units)
1. For single unit installation
2. For multiple units installation (more than two units)
1. For single unit installation
2. For multiple units installation (more than two units)
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
1 When there is an obstruction on the outlet side2
1) When the overhead space is open (There is no limit to the height of the obstruction on the outlet side.)
When there are obstructions on both the inlet and outlet sides(When the obstruction on the outlet side is higher than the unit itself)
3
H
L
500
or more
100
or more
L H
100 or more
100 or more100 or more
100 or more
500 or more
100 or more
500 or less
1000
or m
ore
An obstruction in the overhead space
500 or less
500 or more
1000
or m
ore
An obstruction in the overhead space
150 or more
150 or more150 or more
500 or less
1000
or m
ore
An obstruction in the overhead space
For RNQ90-140MV1/Y1 REMOTE CONTROLLER
Wired type
Staple17
17
0~5
117
17(fl12~fl16)
A EXposed body, exposed cord C Exposed body, embedded code
( Distance between remote controller and control box )
B Exposed body, embedded cordConduit
CONTROL BOX
Through hole
Size
Specifications of cord
0.75~1.25 mm2
Total length 500 m
Type Vinyl cord with sheath or cable (Insulated thickness: 1 mm or more)
Note) 1. Remote controller cord and staple are not attached. they are field supplied parts.
Note) The dimension of hole.
* Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more)
120
120
17 18
42
84
38
Cord outlet hole
282346
Wireless type
BRC1C61
BRC1NU61
BRC7NU66
Transmitting part
157
62 17.5
Liquid crystalremote controller(Wireless)
Remote controllerholder
CEILING SUSPENDED TYPE
A
22
38
6
A
41
13
A25R2
7
B
44.5
10
20
B
A
25
25 17
41.5
7
A
B
111
119
246
Hole type
a
10
20
4
B
a (mm)
ReceiverThe Front
Remote controller holderinstallation procedure<Installation to wall surface>
Remote controller holderinstallation procedure<Installation to wall surface>
Transmitting part
115.
5
54 18.1
Remote controller(Wireless)
Remote controllerholder
Receiver installation procedure
Service space for ceiling installation
Receiver detail
Note :
Mor
e th
an 9
0(S
revi
ce s
pace
)
120
72 83.5
106
(Ceil
ing o
penin
g)
70 180.5
35 49(Ceiling opening)
2-5x9 Slot
Switch box(field Supplied parts)
Do not install more than 3 receivers in the vicinity of one another.With 4 or more units, there is always the possibility of malfunction
Remote controller dimensions
Remote controller installation procedure
Receiver detail
Remote controller dimensions
BRC7F633F BRC4C64 CEILING MOUNTED CASSETTE TYPE <Round Flow>
• Receiver installation procedure • Receiver detailReceiver
Drain pipingside
Refrigerantpiping side
Decoration panel
19
Upper case Lower case
40
2346
2848.5
4284
5X7 oblong hole
Code outlet hole5X15 oblong hole
Lower case portion
Lower case portion
Staple
19
A Exposed cord C Embedded cord(use switch box)
B Embedded cord
84
46Switch box for two switchex.) KJB211A(optional accessory)
Condit
19
0~5
Switch box [field supplied part]
(Between remotecontroller and control box)
48.5
19
Note)2Through hole
40
( 8- 10)
84
28
Switch box for one switchex.) KJB111A(optional accessory)
• Installation method
2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller.
Note) 1. Remote controller cord and staple are not attached. They are field
supplied parts.
Size
Specifications of cord
0.75~1.25 mm2
Total length 500 m
Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
BRC1E62
(Green)120
120
Operationlamp
Top left outlet
Left outlet
Top centeroutlet
DIMENSIONS (Unit: mm) Installation service space for outdoor unit (Unit: mm)