PCXPDS14 60Hz Ducted Split B-Series

TRANSCRIPT

Page 1: PCXPDS14 60Hz Ducted Split B-Series

PCXPDS14

Cooling Only [60Hz]

Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.

©2014-07

Ducted SplitB Series

Page 2: PCXPDS14 60Hz Ducted Split B-Series

Ducted Split B Series

RC150DRC75/100/125BFD125/150BFD75/100B 2FD200B 2FG250B 3FG350B 4FG400B 4FG500B

› Wide Range Of Product› Modular Combination Of Single Indoor Unit To Multiple Outdoor Units› Partial Loading Features For Units With More Than 2 Outdoor Units› Convertible Air Discharge› Changeable Drive Package (Field Supplied) For Belt Driven Models› Single Compressor System : Wired Handset BRC51B64 Is Supplied As Standard› Multi Compressor System : Wired Handset BRC51C61 Is Supplied As Standard

Specification for Ducted Split - B Series - Cooling only

Components• Expansion device: Thermal expansion valves are supplied as standard.• Compressor: Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration.• Indoor fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements.• Condenser fan blade: Use of well designed propeller fan blade has effectively reduce the sound pressure level.

RefrigerationThe outdoor units are come with factory Nitrogen holding charge. Installer will need to charge the HCFC-22 (R-22) refrigerant at site according to the manual recommendation

Long Piping ApplicationStandard maximum piping length of Daikin ducted split is up to 35m for Cooling Only model.

Safety Features• High Pressure and Low Pressure protection. • Compressor & motor current overload protection.• Sensor fault indication. • Minimum compressor running time to ensure oil return.• Phase sequential is used to detect for any wrong phase and phase loss during installation and operation

Command PerformanceStandard units are equipped with microprocessor controller and it is equipped with following functions:• Mode selection• Temperature Setting• Timer (delay timer for BRC51B and real time timer for BRC51C)• Error code display

Auto-Random RestartWhenever unit stop due to power failure during operation unit automatically restarts at last setting condition once the power is resumed. However, the compressors will restart randomly if more than one unit is installed and share the same phase of power. Option is provided to cancel this feature.

Cabinet ConstructionEither indoor or outdoor is coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for severe external conditions.Service Panel is available at the convenience side for both indoor and outdoor.

Indoor Air Throw DirectionConvertible discharge air direction at indoor unit has made it versatile to various architectural designs. (Applicable to size 125 and above only)

Changeable Drive PackageNon-standard external static pressure & airflow requirement can be sized by changing the factory fitted drive package. (Limited for belt drive model only)

Easy To Reach Access ValveDischarge line and suction line access valve is accessible without opening the unit casing.

InsulationPolyethylene (PE) insulation is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethylene, which is also a type of Closed Cell Foam (CCF) insulation has offered the following advantages:• Durable external surface that resists dirt tough and resilient• Higher degree of puncture resistance when compared to fiberglass• Easily cleaned surface (if necessary) to further resist microbial growth

Choices Of Wired Controller

BRC51B64 (C/0) BRC51C61

FD75BXVL FD100BXVLRC75BXTL9 RC100BXTL9

FD125BXTLRC125BXTL9

FD150BXVLRC150DXTL9

Btu/h 73000214002.63

220/1/602500

98/71/4950/50/48

572140260589

220/3N~/6065

946939

1116155

90000263802.67

220/1/603200

98/78/6153/51/49

572140260593

220/3N~/6061

946939

1116164

118000345802.45

220/3N~/60420015058

8851540850183

220/3N~/6065

946939

1116169

148000433802.92

220/3N~/60460015060

8851540850190

220/3N~/6067

114210831083268

WW/W

Power Supply V/Ph/HzAir Flow CFMExternal Static Pressure PaSound Pressure Level dBAHeight mmWidth mmDepth mmNet Weight kgPower Supply V/Ph/HzSound Pressure Level dBAHeight mmWidth mmDepth mmNet Weight kg

Indoor Model NameOutdoor Model Name

Nominal Cooling Capacity

Nominal EER

Indo

orO

utdo

or

2FD200BXTLRC100BXTL9 X 2

2FG250BXTLRC125BXTL9 X 2

2FG300BXTLRC150DXTL9 X 2

3FG350BXTLRC100BXTL9 + RC125BXTL9 X 2

Btu/h 180000527602.65

220/3N~/60640015061

8851794850220

220/3N~/6065

946939

1116164

236000691702.42

220/3N~/60800020063

123117661069343

220/3N~/6065

946939

1116169

296000867502.85

220/3N~/60900020066

123117661069343

220/3N~/6067

114210831083268

326000955502.34

220/3N~/6010500

20066

148620221069462

220/3N~/6065

946939

1116164 + 169

WW/W

Power Supply V/Ph/HzAir Flow CFMExternal Static Pressure PaSound Pressure Level dBAHeight mmWidth mmDepth mmNet Weight kgPower Supply V/Ph/HzSound Pressure Level dBAHeight mmWidth mmDepth mmNet Weight kg

Indoor Model NameOutdoor Model Name

Nominal Cooling Capacity

Nominal EER

Indo

orO

utdo

or

4FG400BXTLRC100BXTL9 x 4

3FG450BXTLRC150DXTL9 x 3

4FG500BXTLRC125BXTL9 x 4

Btu/h 444000130130

2.86220/3N~/60

1350025068

148621741336564

220/3N~/6067

114210831083268

472000138340

2.35220/3N~/60

1500025068

148621741336606

220/3N~/6065

946939

1116169

WW/W

Power Supply V/Ph/HzAir Flow CFMExternal Static Pressure PaSound Pressure Level dBAHeight mmWidth mmDepth mmNet Weight kgPower Supply V/Ph/HzSound Pressure Level dBAHeight mmWidth mmDepth mmNet Weight kg

Indoor Model NameOutdoor Model Name

Nominal Cooling Capacity

Nominal EER

Indo

orO

utdo

or

Single Condenser System- FD

Multi Condenser System - 2FD, 2FG, 3FG, 4FG

360000 105510

2.73 220/3N~/60

12000 200

66 1486 2174 1336 513

220/3N~/60 65

946 939

1116 164

Max. Allowable LengthMax. Allowable Elevation

mm

5020

5020

5020

5020

Max. Allowable LengthMax. Allowable Elevation

mm

5020

5020

5020

5020

Max. Allowable LengthMax. Allowable Elevation

mm

5020

5020

5020