Page 1: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

PediTred G4 Installation Instructions

Page 2: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

Table of Contents

Level Base…………………..…………………………………………………………………………………………………………………………………………………Page 3-6

No Frame……………………………………………………………………………………………………………………………………………..…………………………Page 7-10

Pipestem Frame.………………………………………………………………………………………………………………………………………………………Page 11-14

Surface Mounted Aluminum Frame ….…………………………….………………………………………………………………...Page 15-18

TNG Frame………………………………………………………………………………………………………………………………………………………………….…Page 19-22

Page 3: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

PediTred G4

1. Site Prep

• Use wood forms to prepare a recess in the concrete a minimum 1” depth to final finished floor surface.• Recess should be made to overall size of unit, plus a 1/16” on all sides of the recess to allow for clearance.• Ensure the LB frames exposed surface will be flush with the finished floor.• After concrete has cured, remove the wood forms.• (See Illustration B) below.

2. Assemble Frame

• Assemble the level base frame utilizing the corner locks provided. The ends of the frame pieces have been pre-mitered to allow for quick assembly.(See Illustration A)

3. Set Frame

• Set the frame assembly in the formed recess.• Shim the frame as required 24” o.c. to elevate the frame assembly to finished floor height.• Before fastening, double check the finished floor surface height, and ensure that frame assembly is both plumb

and square.• Drill a pilot hole through aluminum frame at each shim location and use a 5/32” masonry anchor bit to drill hole

into concrete.• Install each 3/16” masonry anchors. (anchors and bit included in hardware package)• Clean the concrete recess to remove all dirt, oily film, and debris..

With Level Base (LB) Frame

Illustration A

Illustration B

Page 4: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

4. Grout

• Grout the concrete pit surface to bring bottom of recess flush with top of lower frame leg using a waterproof self-leveling grout.

• Recommended brands:• Quikrete #1585 mixed with #8610 Acrylic Fortifier

• For technical assistance, call Quikrete @ 800-282-5828, www.quikrete.com• VinylCrete with Acrylic Fortifier

• For technical assistance, call UMACO Inc @ 978-453-8881 www.umaco.com• Pour and level grout using the legs within the frame opening as screed points.

Important: the bed surface must be smooth and level to ensure proper mat installation, alignment, and to prevent tripping hazards.

Allow the grout material sufficient time to cure properly before inserting the Pedimat, Pedimat AA, orTreadline within the framed opening.

5. PediTred Installation

Locator Bars are included with the hardware package and must be installed to ensure proper alignment of the Peditred rails.• Upon final location of the Peditred within the frame, mark the treadrail centerline of the first and second rail on

the exposed frame surface at each corner location. (Illustration D)• Position the locator bar along the marked line. (Illustration F)• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit.• Using a #2 Phillips drive, secure each locator bar with two 3/16” masonry anchors. (Illustration E)• Attach two locator bars per corner.

With Level Base (LB) Frame

Illustration C

D E F

PediTred G4

Page 5: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

• Install Peditred.6. Attaching Modules (If Necessary)

• Attach modules 1,2, and 3 (example) together as shown below utilizing a rubber mallet.• Depending on the size of the Peditred, there may be multiple modules needed to make one complete unit.

These modules must be joined together as shown in illustration G.

7. Splice Connections for Large Grids Over 144” Wide

• Trial fit assembly into frame area – trim end vinyl as required with a utility knife for proper fit. Align and secure center tread rail with locator bar.

Illustration H

With Level Base (LB) Frame

Illustration G

Illustration J

PediTred G4

Page 6: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

With Level Base (LB) Frame

FAQ on this step

Q: Why is my Peditred larger or smaller than the recess?A: The vinyl carriers on the underside of the Peditred may expand or contract during shipping. If the Peditred is smaller than the recess, simply roll up and unroll the grid. This will stretch the carriers and allow it to expand. If the Peditred is larger, tuck the end vinyl into the recess and compress the rails flat. End vinyl may need to be trimmed.

8. Completion

It is necessary to cover the installation with ¾” plywood until all additional project work is completed. This will protect the Peditred from potential abuse during the construction phase. Damage occurring from inadequate protection during this phase may void the manufacturer’s warranty.

9. Cleaning and Maintenance Instructions for Pedisystem

• Manufacturer’s suggested safe rolling load for the Peditred G4 is 1000# per wheel• Heavy loads beyond this weight may damage the units, contributing to their premature failure or creating a

tripping hazard.• Vacuum surface regularly with beater brush attachment to allow contact with various surfaces of entrance

flooring.• Before deep cleaning the surface, roll unit back to remove dirt collected underneath as needed. Dirt should be

removed with professional vacuum cleaner and should not be allowed to build up to the point where a level mat surface is affected.

• Deep clean quarterly, either by removing unit to an area where it can cleaned with a powerwasher (on light setting to avoid carpet damage) or.

• Shampoo the unit in place (soap/water extraction)• It is recommended that shampooing take place overnight to allow carpet fibers to dry thoroughly before heavy

traffic resumes.• Suggestions for pre-treating the area prior to shampooing• Remove gum or other sticky substance by applying a commercial freeze spray to the affected area. This

should allow the residue to break off easily.• For ground-in dirt showing in high traffic areas, add one cup of bleach per gallon of warm water and use stiff

brush to pre-treat carpet fibers.• If aluminum needs cleaned, use stiff nylon bristle brush to clean with shampoo mixture prior to shampooing

entire unit.• To achieve the most effective suction of the shampooer, run the wand perpendicular to the rails and not along

the length of the carpet strips.• Take care when mopping surrounding floor area. Keep mop away from mat or grid. The aggressive texture of

the carpet inserts may grab lint when the mop comes in contact, potentially causing unsightly lint collection at edges of unit.

• Replacement inserts are available: See www.impactspecialties.com or call 1-888-424-6287 for more information and for contact information for your local representative.

PediTred G4

Page 7: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

PediTred G4

1. Site Prep

• Use wood forms to prepare a recess in the concrete a minimum 11/16” depth to final finished floor surface.• After concrete has cured, remove the wood forms. (Illustration A) below• Clean the concrete recess to remove all dirt, oily films, and debris.

2. PediTred Installation

Locator Bars are included with the hardware package and must be installed to ensure proper alignment of the Peditred rails.• Upon final location of the Peditred within the recess, mark the treadrail centerline of the first and second rail at

each corner location. (Illustration B)• Position the locator bar along the marked line. (Illustration D)• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit.• Using a #2 Phillips drive, secure each locator bar with two 3/16” masonry anchors. (Illustration C)• Attach two locator bars per corner.• Install Peditred.

With No Frame

Illustration A

B C D

Page 8: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

3. Attaching Modules (If Necessary)

• Depending on the size of the Peditred, there may be multiple modules needed to make one complete unit. These modules must be joined together as shown in illustration E.

• Attach modules 1,2, and 3 (example) together as shown below utilizing a rubber mallet..

4. Splice Connections for Large Grids Over 144” Wide

PediTred G4

With No Frame

Illustration E

Illustration F

Page 9: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

• Trial fit assembly into frame area – trim end vinyl as required with a utility knife for proper fit.• Align and secure center tread rail with locator bar.

FAQ on this step

Q: Why is my Peditred larger or smaller than the recess?A: The vinyl carriers on the underside of the Peditred may expand or contract during shipping. If the Peditred is smaller than the recess, simply roll up and unroll the grid. This will stretch the carriers and allow it to expand. If the Peditred is larger, tuck the end vinyl into the recess and compress the rails flat. End vinyl may need to be trimmed.

5. Completion

It is necessary to cover the installation with ¾” plywood until all additional project work is completed. This will protect the Peditred from potential abuse during the construction phase. Damage occurring from inadequate protection during this phase may void the manufacturer’s warranty.

PediTred G4

With No Frame

Illustration G

Page 10: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

6. Cleaning and Maintenance Instructions for Pedisystem

• Manufacturer’s suggested safe rolling load for the Peditred G4 is 1000# per wheel• Heavy loads beyond this weight may damage the units, contributing to their premature failure or creating a

tripping hazard.• Vacuum surface regularly with beater brush attachment to allow contact with various surfaces of entrance

flooring.• Before deep cleaning the surface, roll unit back to remove dirt collected underneath as needed. Dirt should be

removed with professional vacuum cleaner and should not be allowed to build up to the point where a level mat surface is affected.

• Deep clean quarterly, either by removing unit to an area where it can cleaned with a powerwasher (on light setting to avoid carpet damage) or...

• Shampoo the unit in place (soap/water extraction)• It is recommended that shampooing take place overnight to allow carpet fibers to dry thoroughly before heavy

traffic resumes.• Suggestions for pre-treating the area prior to shampooing• Remove gum or other sticky substance by applying a commercial freeze spray to the affected area.• This should allow the residue to break off easily.• For ground-in dirt showing in high traffic areas, add one cup of bleach per gallon of warm water and use stiff

brush to pre-treat carpet fibers.• If aluminum needs cleaned, use stiff nylon bristle brush to clean with shampoo mixture prior to shampooing

entire unit.• To achieve the most effective suction of the shampooer, run the wand perpendicular to the rails and not along

the length of the carpet strips.• Take care when mopping surrounding floor area. Keep mop away from mat or grid. The aggressive texture of

the carpet inserts may grab lint when the mop comes in contact, potentially causing unsightly lint collection at edges of unit. Replacement inserts are available: See www.impactspecialties.com or call 1-888-424-6287 for more information and for contact information for your local representative.

PediTred G4

With No Frame

Page 11: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

PediTred G4

1. Site Prep

• Clean the floor surface to remove all dirt, oily film, and debris.• Locate and mark final location in which the Peditred will be placed

2. Assemble Frame

• The frame pieces have been pre-mitered to allow for quick assembly.• Remove the protective layer of the tape, which is adhered to the bottom of the frame, and set in its final location.

(See Illustration A)

Note: 3/16” masonry anchors can be used to fasten the frame in high traffic applications)

3. Peditred Installation

• Locator Bars are included with the hardware package and must be installed to ensure proper alignment of the Peditred rails.

• • Upon final location of the Peditred within the frame, mark the treadrail centerline of the first and second rail on the exposed frame surface at each corner location. (Illustration B).

• Position the locator bar along the marked line. (Illustration D)• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit.• Using a #2 Phillips drive, secure each locator bar with two 3/16” masonry anchors. (Illustration C)• Attach two locator bars per corner.• Install Peditred

With Pipestem Frame

Illustration A

B C D

Page 12: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

4. Attaching Modules (If Necessary)

• Attach modules 1,2, and 3 (Illustration E & F) together as shown below utilizing a rubber mallet.• Depending on the size of the Peditred, there may be multiple modules needed to make one complete unit.

These modules must be joined together as shown in (Illustration E).

5. Splice Connections for Large Grids Over 144” Wide

PediTred G4

With Pipestem Frame

Illustration E

Illustration F

Page 13: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

• Trial fit assembly into frame area. Trim end vinyl as required with a utility knife for proper fit.• Align and secure center tread rail with locator bar. (Illustration G).

FAQ on this step

Q: Why is my Peditred larger or smaller than the opening between the frames?A: The vinyl carriers on the underside of the Peditred may expand or contract during shipping. If the Peditred is smaller than the opening, simply roll up and unroll the grid. This will stretch the carriers and allow it to expand. If the Peditred is larger, tuck the end vinyl into the recess and compress the rails flat. End vinyl may need to be trimmed.

6. Completion

It is necessary to cover the installation with ¾” plywood until all additional project work is completed. This will protect the Peditred from potential abuse during the construction phase. Damage occurring from inadequate protection during this phase may void the manufacturer’s warranty.

PediTred G4

With Pipestem Frame

Illustration G

Page 14: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

6. Cleaning and Maintenance Instructions for Pedisystem

• Manufacturer’s suggested safe rolling load for the Peditred G4 is 1000# per wheel• Heavy loads beyond this weight may damage the units, contributing to their premature failure or creating a

tripping hazard.• Vacuum surface regularly with beater brush attachment to allow contact with various surfaces of entrance

flooring.• Before deep cleaning the surface, roll unit back to remove dirt collected underneath as needed. Dirt should be

removed with professional vacuum cleaner and should not be allowed to build up to the point where a level mat surface is affected.

• Deep clean quarterly, either by removing unit to an area where it can cleaned with a powerwasher (on light setting to avoid carpet damage) or..

• Shampoo the unit in place (soap/water extraction)• It is recommended that shampooing take place overnight to allow carpet fibers to dry thoroughly before

heavy traffic resumes.• Suggestions for pre-treating the area prior to shampooing

• Remove gum or other sticky substance by applying a commercial freeze spray to the affected area. This should allow the residue to break off easily

• For ground-in dirt showing in high traffic areas, add one cup of bleach per gallon of warm water and use stiff brush to pre-treat carpet fibers.

• If aluminum needs cleaned, use stiff nylon bristle brush to clean with shampoo mixture prior to shampooing entire unit.

• To achieve the most effective suction of the shampooer, run the wand perpendicular to the rails and not along the length of the carpet strips.

• Take care when mopping surrounding floor area. Keep mop away from mat or grid. The aggressive texture of the carpet inserts may grab lint when the mop comes in contact, potentially causing unsightly lint collection at edges of unit.

• Replacement inserts are available: See www.impactspecialties.com or call 1-888-424-6287 for more information and for contact information for your local representative.

PediTred G4

With Pipestem Frame

Page 15: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

PediTred G4

1. Site Prep

• Clean the floor surface to remove all dirt, oily film, and debris.• Locate and mark final location in which the Peditred will be placed

2. Assemble Frame

• The frame pieces have been pre-mitered to allow for quick assembly.• Remove the protective layer of the tape, which is adhered to the bottom of the frame, and set in its final location.

(See Illustration A)

Note: 3/16” masonry anchors can be used to fasten the frame in high traffic applications)

3. Peditred Installation

• Locator Bars are included with the hardware package and must be installed to ensure proper alignment of the Peditred rails.

• • Upon final location of the Peditred within the frame, mark the treadrail centerline of the first and second rail on the exposed frame surface at each corner location. (Illustration B).

• Position the locator bar along the marked line. (Illustration D)• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit.• Using a #2 Phillips drive, secure each locator bar with two 3/16” masonry anchors. (Illustration C)• Attach two locator bars per corner.• Install Peditred

With Pipestem Frame

Illustration A

B C D

Page 16: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

4. Attaching Modules (If Necessary)

• Attach modules 1,2, and 3 (Illustration E & F) together as shown below utilizing a rubber mallet.• Depending on the size of the Peditred, there may be multiple modules needed to make one complete unit.

These modules must be joined together as shown in (Illustration E).

5. Splice Connections for Large Grids Over 144” Wide

PediTred G4

With Pipestem Frame

Illustration E

Illustration F

Page 17: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

• Trial fit assembly into frame area. Trim end vinyl as required with a utility knife for proper fit.• Align and secure center tread rail with locator bar. (Illustration G).

FAQ on this step

Q: Why is my Peditred larger or smaller than the opening between the frames?A: The vinyl carriers on the underside of the Peditred may expand or contract during shipping. If the Peditred is smaller than the opening, simply roll up and unroll the grid. This will stretch the carriers and allow it to expand. If the Peditred is larger, tuck the end vinyl into the recess and compress the rails flat. End vinyl may need to be trimmed.

6. Completion

It is necessary to cover the installation with ¾” plywood until all additional project work is completed. This will protect the Peditred from potential abuse during the construction phase. Damage occurring from inadequate protection during this phase may void the manufacturer’s warranty.

PediTred G4

With Pipestem Frame

Illustration G

Page 18: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

6. Cleaning and Maintenance Instructions for Pedisystem

• Manufacturer’s suggested safe rolling load for the Peditred G4 is 1000# per wheel• Heavy loads beyond this weight may damage the units, contributing to their premature failure or creating a

tripping hazard.• Vacuum surface regularly with beater brush attachment to allow contact with various surfaces of entrance

flooring.• Before deep cleaning the surface, roll unit back to remove dirt collected underneath as needed. Dirt should be

removed with professional vacuum cleaner and should not be allowed to build up to the point where a level mat surface is affected.

• Deep clean quarterly, either by removing unit to an area where it can cleaned with a powerwasher (on light setting to avoid carpet damage) or..

• Shampoo the unit in place (soap/water extraction)• It is recommended that shampooing take place overnight to allow carpet fibers to dry thoroughly before

heavy traffic resumes.• Suggestions for pre-treating the area prior to shampooing

• Remove gum or other sticky substance by applying a commercial freeze spray to the affected area. This should allow the residue to break off easily

• For ground-in dirt showing in high traffic areas, add one cup of bleach per gallon of warm water and use stiff brush to pre-treat carpet fibers.

• If aluminum needs cleaned, use stiff nylon bristle brush to clean with shampoo mixture prior to shampooing entire unit.

• To achieve the most effective suction of the shampooer, run the wand perpendicular to the rails and not along the length of the carpet strips.

• Take care when mopping surrounding floor area. Keep mop away from mat or grid. The aggressive texture of the carpet inserts may grab lint when the mop comes in contact, potentially causing unsightly lint collection at edges of unit.

• Replacement inserts are available: See www.impactspecialties.com or call 1-888-424-6287 for more information and for contact information for your local representative.

PediTred G4

With Pipestem Frame

Page 19: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

PediTred G4

1. Site Prep

• Use wood forms to prepare a recess in the concrete an exact 3/4” depth to final finished floor surface.• Recess should be made to overall size of unit, plus a 1/16” on all sides of the recess to allow for clearance.• Ensure the Tapered Angle frames exposed surface will be flush with the finished floor.• After concrete has cured, remove the wood forms. (See Illustration A) below.

2. Assemble Frame

• Assemble the tapered angle frame. The ends of the frame pieces have been pre-mitered to allow for quick assembly

3. Set Frame

• Set the frame assembly in the formed recess.• Before fastening, double check the finished floor surface height, and ensure that the frame assembly is both

plumb and square.• Install 3/16” masonry anchors into the factory predrilled holes. (anchors and bit included in hardware package)• Clean the concrete recess to remove all dirt, oily film, and debris.

With TNG Frame

Illustration A

Page 20: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

4. Peditred Installation

Locator Bars are included with the hardware package and must be installed to ensure proper alignment of the Peditred rails.• Upon final location of the Peditred within the frame, mark the treadrail centerline of the first and second rail on

the exposed frame surface at each corner location. (Illustration B)• Position the locator bar along the marked line. (Illustration D)• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit.• Using a #2 Phillips drive, secure each locator bar with two 3/16” masonry anchors. (Illustration C)• Attach two locator bars per corner.• Install Peditred.

5. Attaching Modules (If Necessary)

• Attach modules 1,2, and 3 (example) together as shown below utilizing a rubber mallet.• Depending on the size of the Peditred, there may be multiple modules needed to make one complete unit.

These modules must be joined together as shown in Illustration E.

PediTred G4

With TNG Frame

B C D

Illustration E

Page 21: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

6. Splice Connections for Large Grids Over 144” Wide

• Trial fit assembly into frame area. Trim end vinyl as required with a utility knife for proper fit.• Align and secure center tread rail with locator bars.• (Illustration G)

PediTred G4

With TNG Frame

Illustration F

Illustration G

Page 22: PediTred G4 Installation Instructions - CS Group• Using the locator bar as a guide, drill a pilot hole with a 5/32” masonry bit. • Using a #2 Phillips drive, secure each locator

4005 Royal Drive Suite 100 | Kennesaw, GA 30144 | 888-424-6287 | www.impactspecialties.com

Install Instructions

© C

opyr

ight

201

6 Im

pact

Spe

cial

ties

FAQ on this step

Q: Why is my Peditred larger or smaller than the recess?A: The vinyl carriers on the underside of the Peditred may expand or contract during shipping. If the Peditred is smaller than the recess, simply roll up and unroll the grid. This will stretch the carriers and allow it to expand. If the Peditred is larger, tuck the end vinyl into the recess and compress the rails flat. End vinyl may need to be trimmed.

7. Completion

It is necessary to cover the installation with ¾” plywood until all additional project work is completed. This will protect the Peditred from abuse during the construction phase. Damage occurring from inadequate protection during this phase may void the manufacturer’s warranty.

8. Cleaning and Maintenance Instructions for Pedisystem

• Manufacturer’s suggested safe rolling load for the Peditred G4 is 1000# per wheel• Heavy loads beyond this weight may damage the units, contributing to their premature failure or creating a

tripping hazard.• Vacuum surface regularly with beater brush attachment to allow contact with various surfaces of entrance

flooring.• Before deep cleaning the surface, roll unit back to remove dirt collected underneath as needed. Dirt should be

removed with professional vacuum cleaner and should not be allowed to build up to the point where a level mat surface is affected.

• Deep clean quarterly, either by removing unit to an area where it can cleaned with a powerwasher (on light setting to avoid carpet damage) or.

• Shampoo the unit in place (soap/water extraction)• It is recommended that shampooing take place overnight to allow carpet fibers to dry thoroughly before

heavy traffic resumes.• Suggestions for pre-treating the area prior to shampooing

• Remove gum or other sticky substance by applying a commercial freeze spray to the affected area. This should allow the residue to break off easily.

• For ground-in dirt showing in high traffic areas, add one cup of bleach per gallon of warm water and use stiff brush to pre-treat carpet fibers.

• If aluminum needs cleaned, use stiff nylon bristle brush to clean with shampoo mixture prior to shampooing entire unit.

• To achieve the most effective suction of the shampooer, run the wand perpendicular to the rails and not along the length of the carpet strips.

• Take care when mopping surrounding floor area. Keep mop away from mat or grid. The aggressive texture of the carpet inserts may grab lint when the mop comes in contact, potentially causing unsightly lint collection at edges of unit.

• Replacement inserts are available: See www.impactspecialties.com or call 1-888-424-6287 for more information and for contact information for your local representative

PediTred G4

With TNG Frame