pnomek pressure switch€¦ · they classified depending on pressure seng range. order code 22 p 1...

4
1 LP A2 Pressure Switches are seable due to seng knob on the pressure system It has aluminium case It has sealing ring NBR equipment Long service life due to high-quality micro switch High vibraon, shock resistance The pressure switch has horizontal stacking connecon holes for side flange connecon It has pressure scale for convinient seng Hydraulics and Mobile Hydraulics Pneumacs Heavy-Duty machines Media; Compressed Air and liquids, gas www.pnomek.com.tr Connecon Process Reproducibility Working Tempurature Vibraon Test ( DIN EN 60068-2-6:1996 ) Shock Test ( DIN EN 60068-2-27:1993 ) Working Cycle Viscosity Range : Side Flange Connecon : Within %1 of set pressure : -20 °C...+110 °C : 20 g ( Test Time 30 min. ) : 30 g : 5 000 000 Cycles 2 : 10 - 800 mm /second These values are maximum values and they can not be used at the same me. When you need to use the pressure switch in agressive chemicals or fluids please contact with us. You must sct to rules of clearence standarts Hydraulic oils (fluids). Use filteraon to blocking system errors. It is effecve for long working life of pressure switches. Please avoid using out of indicated values to have a long service from pressure switch. NOTES PNOMEK Safe pressure materials.. ENG LP A2 PRESSURE SWITCH LP A2 pressure switch opens or closes electrical circuit depending on pressure is dropping or rising. Working Pressure, 7 bar to 600 bar, can be set by pressure seng knop on the pressure switch.When you turn the seng knop to clockwise, pressure rises up. It works appropriately under shock and high pressures. The pressure is seable by pressure seng knop on the pressure switch. When customer system is working, pressure switch has seable speciality. An seng knob makes it interesng for customer due to easy and convinient seng of pressure. LP A2 series pressure switches are employed wherever compressed air, fluids gases are used and a precisely set hystherisis is needed. The pressure switch has horizontal stacking connecon holes for side flange connecon. It has mounng design for all axis'. They classified depending on pressure seng range.

Upload: others

Post on 01-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PNOMEK PRESSURE SWITCH€¦ · They classified depending on pressure seng range. ORDER CODE 22 P 1 2 3 Contact connecon schema: 1: COM 2: NC 3: NA Switch funcon : • Terminal 1

1

LP A2 Pressure Switches are se�able due to se�ng knob on the pressure system

It has aluminium case

It has sealing ring NBR equipment

Long service life due to high-quality micro switch

High vibra�on, shock resistance

The pressure switch has horizontal stacking connec�on holes for side flange connec�on

It has pressure scale for convinient se�ng

Hydraulics and Mobile Hydraulics

Pneuma�cs

Heavy-Duty machines

Media; Compressed Air and liquids, gas

www.pnomek.com.tr

Connec�on Process

Reproducibility

Working Tempurature

Vibra�on Test ( DIN EN 60068-2-6:1996 )

Shock Test ( DIN EN 60068-2-27:1993 )

Working Cycle

Viscosity Range

: Side Flange Connec�on

: Within %1 of set pressure

: -20 °C...+110 °C

: 20 g ( Test Time 30 min. )

: 30 g

: 5 000 000 Cycles2: 10 - 800 mm /second

These values are maximum values and they can not be used at the same �me.When you need to use the pressure switch in agressive chemicals or fluids please contact with us. You must s�ct to rules of clearence standarts Hydraulic oils (fluids). Use filtera�on to blockingsystem errors. It is effec�ve for long working life of pressure switches. Please avoid using out of indicated values to have a long service from pressure switch.

NOTES

PNOMEKSafe pressure materials..

ENG

LP A2

PRESSURE SWITCH

LP A2 pressure switch opens or closes electrical circuit depending on pressure is dropping or rising. Working Pressure, 7 bar to 600 bar, can be set by

pressure se�ng knop on the pressure switch.When you turn the se�ng knop to clockwise, pressure rises up. It works appropriately under shock and high

pressures. The pressure is se�able by pressure se�ng knop on the pressure switch. When customer system is working, pressure switch has se�able

speciality. An se�ng knob makes it interes�ng for customer due to easy and convinient se�ng of pressure. LP A2 series pressure switches

are employed wherever compressed air, fluids gases are used and a precisely set hystherisis is needed. The pressure switch has horizontal stacking

connec�on holes for side flange connec�on. It has moun�ng design for all axis'. They classified depending on pressure se�ng range.

Page 2: PNOMEK PRESSURE SWITCH€¦ · They classified depending on pressure seng range. ORDER CODE 22 P 1 2 3 Contact connecon schema: 1: COM 2: NC 3: NA Switch funcon : • Terminal 1

ORDER CODE

www.pnomek.com.tr2 2

P

12

3

Contact connec�on schema:

1: COM

2: NC

3: NA

Switch func�on :

Terminal 1 - 3: When pressure rises, pressure switch has current ( NA )•

Terminal 1 - 2: When pressure rises or it has not any pressure, pressure switch has current ( NC )•

DIN 43650

ELECTRICAL CONNECTION FEATURES

PRODUCT PRODUCT CODECONNECTION

TYPE

LP A2

LP A2 070

LP A2 160

LP A2 300

LP A2 400

LP A2 600

7 ... 70 bar

20 ... 160 bar

20 ... 300 bar

20 ... 400 bar

50 ... 600 bar

NA / NC

PRESSURE RANGEMAXİMUM SYSTEM

PRESSURE

ELECTRICAL CONNECTION TYPE

SIDE FLANGE CONNECTION

PNOMEKSafe pressure materials..

ENG

LP A2

PRESSURE SWITCH

650 bar

650 bar

650 bar

650 bar

750 bar

Page 3: PNOMEK PRESSURE SWITCH€¦ · They classified depending on pressure seng range. ORDER CODE 22 P 1 2 3 Contact connecon schema: 1: COM 2: NC 3: NA Switch funcon : • Terminal 1

www.pnomek.com.tr2 3

PRESSURE DIFFERENTIAL DIFFERENCE GRAPHIC

Pressure Se�ng Range7 ... 70 bar max set pressure 70 bar max system pressure 650 bar

Pressure Se�ng Range20 ... 160 bar max set pressure 160 bar max system pressure 650 bar

Pressure Se�ng Range20 ... 400 bar max set pressure 400 bar max system pressure 650 bar

Pressure Se�ng Range50 ... 600 bar max set pressure 600 bar max system pressure 750 bar

Working Pressure ( bar )

His

tere

siz

(bar

)H

iste

resi

z (b

ar)

His

tere

siz

(bar

)

His

tere

siz

(bar

)H

iste

resi

z (b

ar) Working Pressure ( bar )

Pressure Se�ng Range20 ... 300 bar max set pressure 300 bar max system pressure 650 bar

Working Pressure ( bar ) Working Pressure ( bar )

Working Pressure ( bar )

PNOMEKSafe pressure materials..

ENG

LP A2

PRESSURE SWITCH

Page 4: PNOMEK PRESSURE SWITCH€¦ · They classified depending on pressure seng range. ORDER CODE 22 P 1 2 3 Contact connecon schema: 1: COM 2: NC 3: NA Switch funcon : • Terminal 1

www.pnomek.com.tr2 4

PNOMEKSafe pressure materials.. PNOMEK Hid. Pno. Mak. Kont. Cihazları San. Tic. Ltd. Ş�.

Çalı Sanayi Bölgesi Kırmızı Cd. No:16 Nilüfer -BURSA / TÜRKİYE [email protected]

T. : +90 (224) 251 63 45 F. : +90 (224) 251 63 46

PNOMEKSafe pressure materials..

ENG

LP A2

PRESSURE SWITCH

76,50

m

ax

15

4

Pressure Setting Knob

Pressure Setting

Product description tag

DIN43650 Base

DIN43650 Socket

Side Flange

M5 x 50 mm Screw

40

31

25

86

10

4

4

8 x 2 o-rıng

Not : M5 x 50 Hexagon head blot screw is gave

witch LP A2 series bo�om flange type pressure